Protection of motors and mechanics, reduced load on the mains siemens.com/sirius-soft-starter

Size: px
Start display at page:

Download "Protection of motors and mechanics, reduced load on the mains siemens.com/sirius-soft-starter"

Transcription

1 SIRIUS Soft Starters Protection of motors and mechanics, reduced load on the mains siemens.com/sirius-soft-starter

2 With SIRIUS soft starters, e.g. the acceleration of cooling water pumps in power plants can be optimized and water hammers avoided through special pump stop functions. Contents SIRIUS Devices for the Control Cabinet 4 Soft Starting of Three-Phase Motors 5 Technology in Detail The Soft Principle Soft Starters for Standard Applications SIRIUS 3RW30 and 3RW40 Conversion Made Easy SIRIUS 3RW30 in Detail High Functionality for Minimum Costs SIRIUS 3RW40 in Detail Soft Starters for High-Feature Applications SIRIUS 3RW44 in Detail SIRIUS Soft Starter ES V14 Comfortable Parameterization and Evaluation of SIRIUS 3RW44 Block Library SIRIUS 3RW44 for SIMATIC PCS 7 Parameterization, configuration and visualization of SIRIUS 3RW44 SIRIUS Soft Starters in Practical Use Application Examples Overview of SIRIUS Soft Starters Technical Data Simulation Tool for Soft Starters (STS) 23 2

3 The Ideal SIRIUS Soft Starter for All Applications Today, three-phase motors serve as the ultimate drive concept. Yet, for many cases, direct starting or wye-delta starting may not always be the best solution. Annoying side effects such as mechanical impact in the machine or voltage drops in the line supply frequently occur. With SIRIUS soft starters, these problems are a thing of the past. This seamless range offers a suitable soft alternative for almost any application whether for standard or high-feature starting. Optimum and future-proof machine concepts can be very easily and efficiently realized through the smooth starting of threephase motors. 3

4 SIRIUS Devices for the Control Cabinet SIRIUS soft starters are perfectly matched with the SIRIUS devices for the control cabinet. The modular standard components, which can be flexibly combined, offer everything for the switching, protecting and starting of various consumers. The range features state-of-the-art technology and offers continuous innovations such as compact soft starter solutions, solid-state switching devices and many further products. With only seven sizes, the range covers the entire power spectrum up to 250 kw. To assemble a load feeder in next to no time, a soft starter, circuit breaker, contactor or overload relay is simply docked on and screw-fastened. By the way, also maintenance is just as easy and fast as the SIRIUS components configuration, installation and wiring. SIRIUS devices for the control cabinet not only feature innovative technology, but are also accommodated in a perfect design, which received the renowned if Product Design Award. Space-saving assembly, outstanding ergonomics as well as excellent design and workmanship ensure a particularly tidy arrangement in the control cabinet. SIRIUS also scores a top ranking in worldwide comparison: Whether in São Paolo, Berlin or Shanghai SIRIUS devices for the control cabinet are available with international approvals all around the world. Our comprehensive service network provides prompt support throughout the entire life cycle in more than 190 countries. The SIRIUS range Load feeders Up to 250 kw easily realizable with standard devices Modularity Everything is matched and can be combined as required Versions and sizes Efficient and flexible, thanks to 7 compact sizes Assembly Fast commissioning, short set-up times, easy wiring Communication Open for SIRIUS NET; connection to AS-Interface, PROFINET and PROFIBUS DP possible Maintenance Extremely durable; low maintenance and reliable Construction Space-saving, thanks to small device width and side-by-side assembly up to 60 C Approvals Worldwide approvals and certification UL, CSA, shipbuilding Design Clear, ergonomic and award-winning Mounting Reliable screw-type or snap-on mounting over entire service life Service Short delivery periods also for spare parts through global logistics network Environment Environmentally friendly production and materials; recyclability; low power loss Accessories Low variance with integrated accessories Spring-loaded technology Fast and safe connection; vibration-proof and maintenance-free 4

5 Soft Starting of Three-Phase Motors What is the operating principle of soft starters? Soft starters limit the starting current and starting torque. This reliably prevents both mechanical stress as well as line voltage dips. The motor voltage is reduced through phase angle control and increased from an adjustable starting voltage up to the line voltage within the ramp time. Thanks to the step-free control of the supply voltage, the motor is adjusted to the driven machine s load behavior. Mechanical operating equipment is accelerated in a particularly gentle manner, which positively influences its operating behavior and prolongs its service life. In short: Soft starting and stopping protects the connected devices and ensures a smooth production flow. Can load feeders be assembled with soft starters? Of course. Fuseless load feeders of small size can be effortlessly assembled with circuit breakers, e.g. the SIRIUS 3RV. Thanks to the integrated overload functionality, also fused feeders can be realized 1) in a rapid and space-saving manner. How is the connection realized? Connection is realized in the same manner as with all other SIRIUS devices for the control cabinet: either using screw-type or spring-loaded terminals. Further connection systems can be employed subject to availability. What about communication? As a matter of course, our soft starters are able to communicate with the outside world. With our high-feature soft starters, this is realized with communication modules for PROFIBUS DP and PROFINET. 1) Not with 3RW30 SIRIUS soft starters advantages at a glance Soft start and soft stop Smooth starting, without steps Reduced current peaks Avoidance of line voltage fluctuations during start-up Reduced load on the power supply system Reduced mechanical load in the drive Considerable space savings and reduced wiring compared to other starters Maintenance-free switching Ease of handling Perfectly matched with SIRIUS devices for the control cabinet 5

6 Technology in Detail The Soft Principle How are the parameters of a soft starter set? With our standard soft starters, the ramp-up time, starting voltage and ramp-down time can be comfortably set via potentiometers. The values can be adjusted particularly finely within the usual setting ranges. For soft starters with motor overload protection, this also applies to the nominal motor current, the selection of the tripping class and the settable current limiting. The multiple functions of our high-feature soft starters are set rapidly and comfort ably via the integrated keypad with menu-prompted graphical display. Also commissioning and diagnostics are realized via this keypad. Why is torque control the better solution? Current and voltage fluctuations upon start-up are problems frequently encountered by operators of power supply systems. Your machines are then stressed by abrupt torque fluctuations. The soft torque control of our highfeature soft starters minimizes the maintenance expenditures for your machines. How about motor overload protection? No problem: Our soft starters come with integrated motor overload protection for many applications. This does away with additional wiring costs and even protects the soft starter against overload. For all other cases, you can utilize the advantages of our further SIRIUS devices for the control cabinet by employing our circuit breakers or overload relays. All components are perfectly matched. What are the advantages of the inside-delta circuit? With inside-delta circuits, the soft starter s phases are switched in series with the individual motor windings, thanks to which the soft starter merely has to conduct the delta current, i. e. 58% of the nominal motor current (conductor current). Automatic recognition of the circuit type by our soft starters partially facilitates the application of considerably smaller devices. Do all three phases have to be controlled? No, this is not required for operational switching. Also for smooth motor start using our soft alternative, two controlled phases are sufficient with standard soft starters. Moreover, our solution not only saves costs, but also space in the control cabinet. However, the third controlled phase is required for inside-delta circuits. What are the benefits of settable current limiting? More and more power supply companies request compliance with specific current limit values during start-up to minimize the load on the power supply systems posed by high starting currents. This requirement can be perfectly met with the settable current limiting of our soft starters. Is an external bypass contactor required? No. Thanks to integrated bridging contact systems, bypass contactors are unnecessary while the power semiconductors power loss is nevertheless sustainably minimized. Are there further options for soft motor starting? Soft motor starting can also be realized with a frequency converter. However, this is only reasonable if the motor s speed is to be influenced also during operation in addition to the starting phase which increases the costs. 6

7 U M I M M M DOL 3RW I DOL M DOL I I 3RW I N t n n DOL: Direct start : Wye-delta start 3RW: Soft start U M : Motor voltage I M : Motor current M M : Motor torque t: Time t R : Ramp time n: Speed N: Rated values t R M DOL M M N M 3RW M M n N n N n 1 M 3RW with voltage ramp 2 M 3RW with torque control 3 M L Load (e.g. pump) n N Different starter types in comparison: Direct start, wye-delta start and soft start Torque control prevents abrupt fluctuations U I = 100 A I e U N L1 L2 L3 U L1 -L3 I = 100 A U S I N t R t Q11 Rated current I e of the starter corresponds to the nominal motor current I N 3 cables to the motor Standard circuit I I = 100 A I B I S U L1- L3 I N I N I e I = 58 A n with current limiting with voltage ramp U S : Starting voltage I S : Starting current I B : Limiting current = Phase control angle Rated current I e of the starter corresponds to 58% of the nominal motor current I N 6 cables (as with wye-delta starters) to the motor Soft start-up with voltage ramp and current limiting Phase control angle principle of the line voltage with soft starters using semiconductor elements Inside-delta circuit 7

8 Soft Starters for Standard Applications SIRIUS 3RW30 and 3RW40 Thanks to their compact design, integrated motor overload and intrinsic device protection, settable current limiting and further features, SIRIUS soft starters are the ideal starter solution for all kinds of standard applications. In the past, typical starter solutions for standard applications were based on direct and wye-delta starting. Today, the advantages offered by soft starter solutions are increasingly utilized. SIRIUS soft starters, for example, not only improve the start-up behavior of escalators, elevators, conveyor belts and pumps, as they simply facilitate a softer start-up than electromechanical starters. Above all, they protect the drive system and the mains supply and thus contribute to reducing the system costs from many points of view. To allow for an optimum adjustment of your drive to the application, we offer a complete portfolio of soft starters in various sizes for almost any application area. For example, the two-phase -controlled SIRIUS 3RW30 is particularly suitable for standard applications up to 55 kw. SIRIUS 3RW40, which additionally offers motor overload, intrinsic device and thermistor motor protection, also masters demanding tasks in a soft manner within the power range from 5.5 to 250 kw. 8

9 9

10 Conversion Made Easy SIRIUS 3RW30 in Detail Belt slippage with heater blowers or sudden water pressure build-up in washing systems are only two of many possible problems which may occur if motors output too much power directly upon start-up. With the SIRIUS 3RW30, such failures are reliably prevented up to 55 kw (with 400 V). The main advantage: As the SIRIUS 3RW30 is the world s only soft starter which offers identical sizes within one device range, it even allows for a direct conversion from direct to soft starting. What are the advantages of soft starting? The advantages are multiple, as the SIRIUS 3RW30 reduces the stress on the motor by reducing the start-up torque and protects the mains against hazardous current peaks through reduced current input. This reliably eliminates line voltage dips. What are the benefits of the SIRIUS 3RW30? The SIRIUS 3RW30 is particularly compact thanks to its consistently optimized power components in hybrid technology. It thus also facilitates side-by-side assembly up to 60 C. It offers fast configuration and easy mounting with only 3 motor supply cables. Small fuseless load feeders can be assembled with a single module with the SIRIUS 3RV circuit breaker. Also fused feeders can be realized in a fast and space-saving manner in combination with SIRIUS 3RB solid-state overload relays. With the SIRIUS 3RW30 in size S0 (45 mm), up to 38 A can be switched 10

11 What about safety and reliability? Thanks to two-phase control and the patented polarity balancing control principle, the SIRIUS 3RW30 is a dependable device which ensures safe and reliable operation. In addition, the integrated bypass contact system reduces the soft starter s heat loss during operation. What are the application areas? The SIRIUS 3RW30 can be employed in almost any standard application up to a motor rating of 55 kw with 400 V. For example for driving conveyor belts, compressors, grinding machines, saws, agitators, etc. How is the SIRIUS 3RW30 set? Ramp-up time and starting voltage can be comfortably and easily set via 2 potentiometers, ensuring optimum starting behavior. How is the soft starter controlled? Without interface relays, the SIRIUS 3RW30 can be directly controlled via the PLC or via the control input. The respective operating state is signaled via a relay output. What are the saving potentials? Space savings in the control cabinet up to 70% are achievable compared to wye-delta starters (example 18.5 kw: 45 mm width instead of 158 mm). The SIRIUS 3RW30 also pays off in terms of mounting: with only 3 instead of 6 motor supply cables. The 3RW30 is also available with removable control terminals. When replacing a 3RW30, the wiring on the terminal thus remains intact ( permanent wiring ) and the terminals are simply snapped onto the new 3RW30, which saves a considerable amount of time. Is the SIRIUS 3RW30 affordable? Absolutely, as it not only ensures reliable operation thanks to standardized production, but is also very attractive in terms of price. How about accessories? In addition to easy-to-mount terminal covers for optimum touch protection, also box terminal blocks, connection modules and labeling strips from the SIRIUS range are available for the 3RW30. 11

12 High Functionality for Minimum Costs SIRIUS 3RW40 in Detail The SIRIUS 3RW40 is the top star among all standard soft starters! Thanks to its innovative control principle, it is not only the world s only two-phase-controlled soft starter in the power range from 5.5 kw (with 400 V) to 250 kw (with 400 V), but is also the smallest available solution thanks to its particularly compact design. It facilitates space-saving and transparent control cabinet arrangements and is thus more than a supplement of our two-phase-controlled SIRIUS 3RW30 soft starter range. What are the benefits of the SIRIUS 3RW40? The SIRIUS 3RW40 soft starter is seamlessly integrated in our SIRIUS portfolio for the control cabinet. As you might already know from experience with other SIRIUS devices, you will thus benefit from identical sizes and uniform connection systems. Regarding size: the particularly compact design of the SIRIUS 3RW40 is at most half as big as that of a comparable wye-delta starter, making space wastage in the control cabinet a thing of the past. Also configuration and mounting are realized rapidly and easily thanks to 3-conductor connection. What are the differences compared to the SIRIUS 3RW30? In general, the SIRIUS 3RW40 offers all the advantages of the 3RW30. In addition, it offers intrinsic device protection and integrated motor protection functions. Just test it and you will be convinced. How is the SIRIUS 3RW40 set? Like with the SIRIUS 3RW30, the starting voltage, ramp-up and ramp-down time of the voltage ramp, as well as the current limiting, can be comfortably set via finely adjustable rotary potentiometers. The nominal motor current, trip class and reset of the motor overload function are adjusted via potentiometers and buttons, as is familiar from the SIRIUS overload relays. What are its outstanding characteristics? The SIRIUS 3RW40 comes with the new patented control principle polarity balancing for the avoidance of DC components in two-phase-controlled soft starters. With twophase-controlled soft starters, the current resulting from the overlapping of the two controlled phases flows in the uncontrolled phase. For physical reasons, this results in an asymmetric distribution of the three phase currents during the motor s start-up process. Even though this distribution cannot be influenced, it is uncritical in most applications. However, besides this asymmetry, the power semiconductors control during the two controlled phases also produces the above-mentioned DC components, which may lead to a loud motor noise with starting voltages lower than 50%. Polarity balancing reliably eliminates these DC components during the start-up phase. It generates an even motor start-up in terms of speed, torque and current rise. The acoustic quality of the start-up process almost reaches the quality of a three-phasecontrolled start-up. Integrated state and fault monitoring via LEDs Easy setting via invariably adjustable rotary potentiometers 12

13 This is made possible by the continuous dynamic alignment and balancing of current half-waves with different polarity during the motor start-up. Does the SIRIUS 3RW40 feature additional protective functions? The SIRIUS 3RW40 is equipped with optimum functionality as standard. An integrated bypass contact system reduces the soft starter s heat loss during operation. This reliably prevents heating of the switching device s environment. The integrated motor overload protection in accordance with IEC makes an additional overload relay unnecessary; this saves space in the control cabinet and reduces the wiring costs in the feeder. The overload trip class can be variably set via a 4-level rotary potentiometer. In addition, intrinsic device protection prevents the thyristors thermally overloading and resulting defects of the power components. Optionally, the thyristors can also be protected against short circuit with SITOR semiconductor fuses. Also inrush current peaks are reliably eliminated, thanks to settable current limiting. Does the SIRIUS 3RW40 offer diagnostics options? Yes, thanks to integrated status and fault monitoring. LEDs provide information on the operating state as well as possible faults, e.g. impermissible release time (CLASS setting), mains or phase failure, missing load, thermal overload or device fault. The two integrated output relays also indicate the operating state and fault signals. Is thermistor motor protection available? Device versions with thermistor motor protection evaluation are available up to a rating of 55 kw (with 400 V). A Thermoclick measuring sensor or PTC (type A) can be directly connected. In addition to thermal motor overload, wire breakage and short circuit in the sensor circuit effect a disconnection of the soft starter. What about reset options? After the soft starter has tripped, various reset options are available, like for intrinsic device and motor overload protection: manual or via the reset button, automatic or (up to 55 kw) remotely via short-term control voltage interruption. Is replacement easy? Yes, also the 3RW40 is equipped with removable control terminals. The wiring on the terminal thus remains intact ( permanent wiring ) in case of replacement and the terminals are simply snapped onto the new 3RW40, which saves a considerable amount of time. How about accessories? We offer a comprehensive range of accessories for our soft starters, e.g. box terminal blocks, accessories for mechanical reset and a module for remote reset (for ratings > 75 kw) as well as a sealing cover and easy-tomount terminal covers for optimum touch protection. Furthermore, snap-on fans are available for the devices up to 55 kw which facilitate mounting of the SIRIUS 3RW40 in almost any installation position and support higher switching duties. In addition, connection modules for electrical and mechanical connections between circuit breaker and soft starter as well as labeling strips from the SIRIUS range are available. 13

14 Soft Starters for High-Feature Applications SIRIUS 3RW44 in Detail Equipped with maximum functionality, the all-round talent SIRIUS 3RW44 even masters difficult start-up and stopping processes in a soft manner. Thanks to innovative torque control, it can be employed for drives up to a power rating of 710 kw (with 400 V) in standard circuit or up to 1200 kw in inside-delta circuit. The functionality designed for ease of operation facilitates optimum operating comfort. What are the benefits of the SIRIUS 3RW44? Thanks to its particularly compact design, which is a characteristic of the entire range of SIRIUS soft starters, the SIRIUS 3RW44 is the ideal solution when space-saving and transparent control cabinet arrangements are required. For optimized motor start-up and stopping, the innovative SIRIUS 3RW44 offers an attractive and efficient alternative to frequency converters. The new torque control and a settable current limiting allow for the use of our highfeature soft starters in almost any application. The SIRIUS 3RW44 guarantees reliable prevention of torque surges and current peaks during motor starting and stopping. This reduces costs both for switchboard dimensioning as well as machinery maintenance. Whether for standard (in-line) or inside -delta circuits the SIRIUS 3RW44 offers saving potentials, particularly in terms of size and device costs. How is the SIRIUS 3RW44 commissioned and operated? Commissioning of the SIRIUS 3RW44 is particularly fast and easy, thanks to a modern and ergonomic menu system. This is facilitated by a keypad with a menu-driven, multi-line graphical display with background illumination. The optimized motor start-up and stopping can be realized rapidly, easily and safely via only few settings in several preselected languages. 4-key operation and plaintext displays on every menu item ensure transparent parameterization and operation at all times. Via the display field, measuring and operating values, as well as warning and fault messages, are continuously displayed during operation and with the control voltage connected. In addition, an external display and operator module can be connected to the soft starter via a connection cable, for example to read actual values directly from the control cabinet door. Does the SIRIUS 3RW44 feature additional protective functions? The SIRIUS 3RW44 is equipped with optimum functionality as standard. An integrated bypass contact system reduces the soft starter s heat loss during operation. This reliably prevents heating of the switching device s environment. Moreover, it features an internal device overload protection against thermal overload of the power section s thyristors, e.g. caused by impermissibly high starting operations. 14 Easy user guidance via the keypad with a menu-guided, multi-line graphical display External display and control module which can be installed in the control cabinet door as well as modules for PROFIBUS DP and PROFINET

15 The wiring costs for installation of an additional motor overload relay are eliminated as the SIRIUS 3RW44 also masters this function. Whether settable release times or thermistor motor protection: With SIRIUS 3RW44, you are always on the safe side! Optionally, the thyristors can also be protected against short circuit with SITOR semiconductor fuses. Also inrush current peaks are reliably eliminated thanks to settable current limiting. Is the SIRIUS 3RW44 communication-capable? Yes, the SIRIUS 3RW44 can be optionally retrofitted with a PROFIBUS DP module. Thanks to its communication capability, control inputs and programmable relay outputs, the SIRIUS 3RW44 can be very easily and rapidly integrated in superior controls. The utilization of a PROFINET communication module, which is also available as option, offers even more advantages: Line and ring bus topologies thanks to integrated switch Media redundancy via MRP protocol Break function and measured values for energy management via PROFIenergy NTP-synchronized time Module replacement without PC Comprehensive diagnostics and fault alarms OPC UA server function for open communication with visualization and control systems Moreover, you will benefit from the break function and from precise measured values for efficient energy management via PROFIenergy. Further advantages: NTP-synchronized time, module replacement without PC, comprehensive diagnostics and fault alarms as well as the OPC UA server function for open communication with visualization and control systems. Last but not least, operating, service and diagnostics data can be called up via a standard web browser. What are the advantages in terms of power loss? Normally, approx. 3 W heat load are generated per every ampere flowing through an actuated thyristor. For motors with 250 kw (with 400 V), this results in a heating power of roughly 1500 W in the switching device s environment. The SIRIUS 3RW44 coolly handles these hot conditions. As a standard, all versions are equipped with mechanical bypass contacts, which bridge the thyristors after detected motor start-up. This consider ably reduces the heat loss occurring during the soft starter s nominal operation. The intelligent hybrid concept, which electronically starts the motor via thyristors and operates it electromechanically via contactor contacts during rated operation, improves the feeder s overall efficiency and additionally reduces the costs for control cabinet dimensioning. What if lower speeds are required? For positioning and set-up tasks, a creep speed function allows for the motor s control in both directions of rotation with reduced torque and settable low speed. What about stopping quickly? For the fast shutdown of driving loads, a new, combined DC brake function is offered for the SIRIUS 3RW44. How about accessories? We offer a comprehensive range of accessories for our soft starters, e.g. an external display and operator module for installation in the control cabinet door or the plug-on PROFIBUS DP module/profinet module. Circuit breaker and soft starter as well as labeling strips from the SIRIUS range are available. Furthermore, easy-to-mount box terminal blocks and sealing covers from the SIRIUS portfolio are available for optimum touch protection. 15

16 Parameterization, Configuration and Visualization Comfortable parameterization and evaluation of SIRIUS 3RW44 with Soft Starter ES With the Soft Starter ES V14 software, the SIRIUS 3RW44 high-feature soft starters can be rapidly and easily parameterized, monitored and diagnosed in service cases. The device parameters can be directly set at the PC and transferred to the soft starter via a serial cable or PROFIBUS/PROFINET connection. Practical versions, easy licensing Soft Starter ES V14 is available in three versions which differ in terms of operating comfort, functional scope and price. A comfortable process eases licensing. Whether Basic, Standard or Premium the suitable license can be rapidly and comfortably downloaded online. Only the actually utilized scope is invoiced and cost-favorable upgrades are offered. With the trial license, you can test the software s functionality without risk for 14 days. The floating license enables access to any user independent of the number of installations. Particularly the Standard and Premium license guarantee optimum engineering efficiency. Easy creation of templates For devices with minor differences, the central modification of few parameters in many identical devices or for the easy parameterization of identical applications, Soft Starter ES V14 offers a powerful tool for the simplified creation of parameter files. The typical file contains all possible parameters, which can all be adjusted by the user. The files can also be easily and rapidly transferred to other devices. Comfortable parameterization with group function For the comfortable parameterization of many devices or applications of the same type, the Soft Starter ES V14 software offers a group function which, in connection with the above-described templates, reads out the parameterization of a group of devices and automatically saves it in a separate file, or transfers the parameters from a group of files to the corresponding device groups. Teleservice via MPI The Soft Starter ES V14 Premium version supports use of the MPI teleservice for remote device diagnostics. This eases diagnostics and maintenance and reduces the response time in service cases. Standard-compliant printouts The software tool considerably simplifies machine documentation as it facilitates the parameterization s printout in accordance with DIN EN ISO The elements to be printed can be simply selected and compiled as required. Advantages of Soft Starter ES V14 Transparent online and offline setting of device functions and parameters Effective diagnostics functions on the soft starter and visualization of important measured values Trace function (oscilloscope function) for recording measured values and events Consistently transparent thanks to printout, logbook and event memory High degree of user-friendliness convenient user interface, with English, German, French, Italian, Spanish and Chinese as possible operating languages Fast, low-cost licensing using a simple licensing procedure (available online too) Time savings through shorter start-up times 16

17 Parameterization / Commissioning Diagnostics / Maintenance Access is either realized via the serial device interface or, with PROFIBUS DPV1/ PROFINET-capable soft starters, via any PROFIBUS/ PROFINET point. Furthermore, the Premium version supports integration in STEP 7 HW-Config. In addition, integration in TIA Portal is possible with the premium version. Testing and controlling the soft starters are also possible without DP/IO master. The software can in this case either be linked to the soft starters with a point-to-point connection (serial) or it can communicate with the individual devices via any point on PROFIBUS/PROFINET. Statistical data (e.g. operating hours, switching cycles, switchoff currents, etc.) can be read out for preventive maintenance. Program versions: 1. Basic Local interface Basic functions for device parameterization 2. Standard Local interface Extended functionality 3. Premium Local and PROFIBUS/PROFINET interface Full functionality Trace Our delivery types: Floating license Full software version on CD with license Upgrade Combo license for parallel use of versions 2007 and V14 of SIRIUS ES Powerpack Special package for converting to a more powerful version with extended functionality within the same software version, e.g. Powerpack Soft Starter ES 2007 for conversion from Standard to Premium Software update service Our special service automatically provides you with all service packs and upgrades for up-to-dateness at all times License download Convenient License Key download from the Industry Mall so that you can obtain additional licenses for your software quickly and easily. Oscilloscope function with SIRIUS 3RW44 soft starters Order data SIRIUS Soft Starter ES V14 Program versions Order number Premium package Floating license 3ZS CC10-0YA5 License download 3ZS CE10-0YB5 Upgrade 3ZS CC10-0YE5 Powerpack (Standard > Premium) 3ZS CC10-0YD5 Software update service 3ZS CC10-0YL5 Order data SIRIUS Soft Starter ES V14 Program versions Order number Standard package Floating license 3ZS CC10-0YA5 License download 3ZS CE10-0YB5 Upgrade 3ZS CC10-0YE5 Powerpack (Basic > Standard) 3ZS CC10-0YD5 Software update service 3ZS CC10-0YL5 Basic package Floating license 3ZS CC10-0YA5 License download 3ZS CE10-0YB5 17

18 Parameterization, Configuration and Visualization Block library SIRIUS 3RW44 soft starter for SIMATIC PCS 7 The PCS 7 block library facilitates the easy and comfortable integration of SIRIUS 3RW44 soft starters in the SIMATIC PCS 7 process control system. The PCS 7 block library SIRIUS 3RW44 soft starter contains the diagnostics and driver blocks corresponding to the diagnostics and driver concept of SIMATIC PCS 7 as well as all elements required for operation and monitoring (icons and faceplates). Integrated functionality for optimum process guidance in all process control systems With the integration of SIRIUS 3RW44 soft starters in the process control system, faults in the motor feeder can be easily and reliably prevented or promptly detected and rectified. This reduces downtimes to a minimum and supports their prevention from the start. Also the output and display of the most important measured values determined by the 3RW44 for example represents a helpful tool for assessment and monitoring of the system s current state. Easy configuration The PCS 7 block library provides all blocks required for the automation system as well as all block icons and faceplates for the operator station required for operation and monitoring. The integration of SIRIUS 3RW44 in SIMATIC PDM facilitates system-spanning device parameterization and diagnostics of 3RW44 soft starters from a central station. Motor block for direct drive control The motor blocks represent the interface between the process control system and the motors controlled by SIRIUS 3RW44. They group all functions for signal processing and provide all information required for operation and monitoring as well as detailed diagnostics. Evaluation of additional motor feeder measurands All measured values determined via the soft starter are visualized and logged via the measured value blocks. The faceplate for measured values is called up via the motor block s faceplate. In addition to the detection of measured values, the measured value block also allows for individual settings, for example in order to respond to measured value exceedance or shortfall by means of motor disconnection or warning. 18

19 Evaluation of the motor feeder s maintenancerelevant data The 3RW44 features powerful functions for the detection and monitoring of maintenance-relevant motor feeder data. For example, the motor s operation time and downtime, switching cycles and overload tripping events are directly detected and saved in the device and provided via the statistics block in the control system if required. Advantages of the PCS 7 block library SIRIUS 3RW44 for SIMATIC PCS 7 Uniform and consistent integration in SIMATIC PCS 7 Standardized blocks for easy integration and optimum operation Improved process transparency thanks to higher information density in the control system System-spanning device parameterization and diagnostics with SIMATIC PDM Delivery and license types Scope of supply: AS blocks and faceplates for the integration of SIRIUS 3RW44 in the PCS 7 process control system, for PCS 7 version 6.1/V7.0 and V8.0/V8.1/V8.2 Engineering software The PCS 7 block library SIRIUS 3RW44 soft starter supplied on CD-ROM entitles the user to execute the required engineering software on an engineering station (single license), including the runtime software for execution of the AS blocks in an automation system (single license). Ordering data CD, incl. electronic documentation: For PCS 7 V6.1/V7.0: 3ZS XX00-0YA0 For PCS 7 V8.0/V8.1/V8.2: 3ZS XX02-0YA0 Runtime software For application of the AS blocks in a further automation system, the respective number of runtime licenses is required, which are supplied without data carrier. Ordering data License without software and documentation: For PCS 7 V6.1/7.0: 3ZS XX00-0YB0 For PCS 7 V8.0/V8.1/V8.2: 3ZS XX02-0YB0 Engineering software migration V7 V8 for upgrade (migration) of an existing engineering software V 6.1/V7.0/V7.1 to V8.0 of the SIRIUS 3RW44 soft starter block library for PCS 7: 3ZS XX10-0YE0 19

20 SIRIUS Soft Starters in Practical Use Application Examples SIRIUS 3RW30 for soft reversing operation of roller conveyors Roller conveyors are, for example, employed in parcel distribution systems for transporting parcels to and from individual work stations. For this purpose, the direction of rotation of the used 11-kW motor has to be adjustable in order to realize both conveyance directions. Roller conveyors pose high requirements The roller conveyor has to start smoothly to prevent damage to the transported goods due to slipping or tilting. The machine s wear and maintenance intervals should be minimized, which is why slippage of the belt drive during start-up must be prevented. The current load upon motor start-up is to be reduced by means of a voltage ramp. The feeder assembly should be as small as possible so as to not exceed the control cabinet s space capacity. Optimum performance with SIRIUS 3RW30 The roller conveyor is rapidly accelerated to the nominal speed without torque surges thanks to optimum setting of the voltage ramp during start-up. The motor s starting current is reduced. Reversing operation of the conveyor belt is realized through contactor interconnection with SIRIUS 3RA13 reversing contactor combinations. Feeder and motor protection are realized with SIRIUS 3RV circuit breakers. The use of SIRIUS system components guarantees maximum wiring reductions and space savings. 20

21 SIRIUS 3RW40 for soft starting of hydraulic pumps SIRIUS 3RW44 for soft starting of milling machines with DC braking In addition to many further application areas, the SIRIUS 3RW40 is optimally suited for the soft start and stop of hydraulic pumps. With a rating of 200 kw, these soft starters are for example used in the production of sheet parts, to drive the respective presses. Hydraulic pumps require sensitive drives The motor s starting current has to be reduced to minimize the load of the superior mains transformer during start-up. Normally, integrated motor protection is called for to reduce wiring expenditures and space requirements in the control box. The hydraulic pump is to be started and stopped in a soft manner, to minimize the mechanical load on the drive and the pump caused by the torque surge during starting and stopping. The SIRIUS 3RW40 offers this sensitivity as a standard The settable current limiting of the SIRIUS 3RW40 limits the load of the mains transformer during motor start-up. Motor protection is ensured by the motor overload relay with settable trip classes integrated in the soft starter. The adjustable voltage ramp ensures the hydraulic pump s start and stop without torque surges. For the production of motor blocks, the required bores are drilled in the motor s aluminum block by means of a milling head. Due to the milling head s high inertia, shutdown of the 15-kW motor is subject to long stopping times, which cause long downtimes for tool changes and set-up operation. The start-up behavior of milling machines requires maximum functionality To prevent excessive wear of the drive belts due to slippage, milling machines require an optimized and torque-controlled start-up behavior. The motor s starting current has to be reduced to minimize the mains load. The motor has to be braked with DC current to reduce the machine s long stopping times. Competent solution with SIRIUS 3RW44 To optimally master the difficult starting conditions, the SIRIUS 3RW44 with torque control and dynamic DC brake function is employed. Slippage of the belts during start-up is prevented by torque control with adjusted torque limiting function. This rapidly accelerates the milling head to the nominal speed without slippage of the belt drives. A higher-level current limiting function reduces the motor s starting current to a set maximum value. The optimum setting of the dynamic DC brake function shuts the milling head down in minimum time. Also motor and device overload protection is excellently mastered by the SIRIUS 3RW44 high-feature soft starter. 21

22 Overview of SIRIUS Soft Starters Technical Data SIRIUS 3RW30 Standard applications SIRIUS 3RW40 Standard applications Rated current at 40 ºC A SIRIUS 3RW44 High-feature applications Rated operational voltage V ) Motor power with 400 V standard circuit kw hp inside-delta circuit kw hp Ambient temperature (operation) C Soft start/stop 2) Voltage ramp Starting/stopping voltage % Ramp-up and ramp-down time s ) Torque control Starting/stopping torque % Torque limiting % Integrated bypass contact system Intrinsic device protection Motor overload protection 3) Thermistor motor protection 4) Integrated remote reset 5) Settable current limiting Inside-delta circuit Breakaway torque Creep speed in both directions of rotation Pump stop 6) DC braking 6) 7) Combined braking 6) 7) Motor heating Communication PROFIBUS/PROFINET (option) External display and operator module (option) Status measured value display Error log Event list Non-return pointer function Trace function 8) Programmable control inputs and outputs Number of parameter sets 1 1 Parameterization software (SIRIUS Soft Starter ES V14) Power semiconductors (thyristors) 2 controlled phases 2 controlled phases 3 controlled phases Screw terminals Spring-type terminals UL/CSA CE mark Soft starting and heavy-duty starting conditions 6) Function available, Function not available 1) With inside-delta circuit up to 600 V 2) 3RW30 only soft start 3) Motor overload protection (ATEX) to be used in combination 4) Optionally up to size S3 (device version) 22 5) With 3RW40 2. up to 3RW404.; with 3RW405. and 3RW407. optional 6) Overdimensioning of soft starter and motor if required 7) Not possible with inside-delta circuit 8) Trace function with Soft Starter ES V14 software Configuration support Electronic selection slide, Simulation Tool for Soft Starters (STS): view/ Technical Assistance: Phone: +49 (0) , technical-assistance@siemens.com

23 Simulation Tool for Soft Starters (STS) Easy input of motor and load data Graphic display of start operations A convenient way of designing soft starters using a simple, quick and easy-to-use interface is possible with the Simulation Tool for Soft Starters (STS). Entering the motor and load data will simulate the application and prompt suggestions for suitable soft starters. The Simulation Tool for Soft Starters (STS) is available free at: Benefits Simple, quick and user-friendly operator interface Detailed and up-to-date Siemens motor database, including IE3 motors. IE4 motor data will follow as soon as it is available. Simulation of heavy starting up to CLASS 30 Update-capable (e.g. motors, load types, functions) Fast simulations with minimum input data Immediate, graphical curve charts of start operations with limit values View in table form of suitable soft starters for the application Technical Assistance: Competent technical support with all industrial control subjects: +49 (0) technical-assistance@siemens.com 23

24 Scan the QR code for further information More information Personally from Monday to Friday from 8.00 am to 5.00 pm (CET) Telephone: Fax: Published by Siemens AG 2017 Digital Factory Control Products P.O. Box Fuerth Germany Artikel No.: DFCP-B Printed in Germany Dispo WS Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested performance features are binding only when they are expressly agreed upon in the concluded contract.

SIRIUS Soft Starters

SIRIUS Soft Starters siemens.com/sirius-soft-starter SIRIUS Soft Starters Protection of motors and mechanics, reduced load on the mains Answers for industry. The Ideal SIRIUS Soft Starter for All Applications Today, three-phase

More information

Dynamics Reinterpreted

Dynamics Reinterpreted Dynamics Reinterpreted The Comprehensive Range of SIRIUS Soft Starters AUSTRALIAN DISTRIBUTORS TEL: 1300 309 303 FAX: 1300 309 308 Enquiries sales@ramelec.com.au Visit us www.ramelec.com.au www.siemens.com/softstarter

More information

SIRIUS Soft Starters Introduction

SIRIUS Soft Starters Introduction Introduction Overview Products at a glance 3RW30/3RW31 3RW40 3RW44 Class 73/74 Enclosed 16 CONTROL SIRIUS soft starters for standard applications SIRIUS 3RW30 soft starters SIRIUS 3RW40 soft starters for

More information

For Operation in the Control Cabinet 3RW Soft Starters

For Operation in the Control Cabinet 3RW Soft Starters General Data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations

More information

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008 Siemens AG 2008 General data The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations

More information

3RW Soft Starters. General data. 6/4 Siemens LV

3RW Soft Starters. General data. 6/4 Siemens LV General data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of peaks Avoidance of mains voltage fluctuations during starting

More information

Motor Starters, Soft Starters and Load Feeders

Motor Starters, Soft Starters and Load Feeders Motor Starters, Soft Starters and Load Feeders Contents Pages Introduction................................... 7/2 For Operation in the Control Cabinet General data.................................. 7/3

More information

Motor Starters, Soft Starters and Load Feeders

Motor Starters, Soft Starters and Load Feeders Motor Starters, Soft Starters and Load Feeders Industrial Controls Product Catalog 201 Section 3RW30 3RW40 3RW30 contents Introduction /2 For Operation in the Control Cabinet General data /3 3RW30 for

More information

Motor Starters, Soft Starters and Load Feeders

Motor Starters, Soft Starters and Load Feeders Motor Starters, Soft Starters and Load Feeders Contents Pages Introduction............................................................6/2 For Operation in the Control Cabinet General data........................................................6/3

More information

Trusted technology for maximum power yield SINAMICS W180 siemens.com/sinamics-w180

Trusted technology for maximum power yield SINAMICS W180 siemens.com/sinamics-w180 The top-performing wind converter Trusted technology for maximum power yield SINAMICS W180 siemens.com/sinamics-w180 SINAMICS W180 Built to redefine the standards Decades of experience in the wind industry,

More information

SIRIUS Soft Starters: Protection of motors and mechanics, reduced load on the mains SIRIUS. Answers for industry.

SIRIUS Soft Starters: Protection of motors and mechanics, reduced load on the mains SIRIUS. Answers for industry. SIRIUS Soft Starters: Protection of motors and mechanics, reduced load on the mains SIRIUS Answers for industry. The Range at a Glance Overview of SIRIUS soft starters Standard applications SIRIUS 3RW03

More information

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE Danfoss VLT Soft Starter The single speed drive 3 1600 A For any soft start situation VLT Soft Starters cover the full range from simple startstop operation to high end performance.

More information

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008 General data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations

More information

3RW40/44 Catalog Supplement July sirius 3RW40 3RW44

3RW40/44 Catalog Supplement July sirius 3RW40 3RW44 RW40/44 Catalog Supplement July 2005 sirius RW40 RW44 Reduced Voltage Electronic Soft Starts Catalog Technical information SIRIUS soft starters /2 Introduction / General data For standard applications

More information

SINAMICS GM150 IGCT version

SINAMICS GM150 IGCT version /2 Overview /2 Benefits /2 Design /6 Function /8 Selection and ordering data /8 Options Technical data /14 General technical data /15 Control properties /15 Ambient conditions /16 Installation conditions

More information

A new star is born. The extended generation of soft starters. sirius SOFT STARTER

A new star is born. The extended generation of soft starters. sirius SOFT STARTER A new star is born. The extended generation of soft starters. sirius SOFT STARTER Planetary nebulae as shown here in the well-known Helix nebula in the Aquarius galaxy are symbolic of the continuous cycle

More information

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options /2 Overview /2 Benefits /2 Design /6 Function /8 Selection and ordering data /8 Options Technical data /1 General technical data /15 Control properties /15 Ambient conditions /16 Installation conditions

More information

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2006

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2006 General data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations

More information

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

A. Danfoss VLT Soft Starter The single speed drive.  For any soft start situation MAKING MODERN LIVING POSSIBLE MAKING MODERN LIVING POSSIBLE Danfoss VLT Soft Starter The single speed drive 3 1600 A For any soft start situation VLT Soft Starters cover the full range from simple start-stop operation to high end performance.

More information

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000 VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000 Soft starts Protect Gear, Goods, Equipment and Environment An AC motor switched directly on to the mains power supply will struggle to reach its nominal

More information

Soft starters SIRIUS 3RW30 / 3RW40. Manual 01/2010. Industrial Controls. Answers for industry.

Soft starters SIRIUS 3RW30 / 3RW40. Manual 01/2010. Industrial Controls. Answers for industry. Soft starters Manual 01/2010 Industrial Controls Answers for industry. Introduction 1 Safety information 2 Industrial Controls Soft starters Manual Product description 3 Product combinations 4 Functions

More information

Softstarters Softstarters

Softstarters Softstarters , PSS & PST(B), PSS & PST(B) Low Voltage Products & Systems 6.1 General information PSR PSS From the moment the first electrical motors appeared, engineers have been searching for a way to avoid electrical

More information

Low-Voltage Controls and Distribution

Low-Voltage Controls and Distribution Motor Starters, Soft Starters and Load Feeders 3RW30 / 3RW40 Soft Starters Reference Manual April 2009 Low-Voltage Controls and Distribution Motor Starters, Soft Starters and Load Feeders 4 Introduction

More information

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS MCD 3000 Soft starter THE PERFECT SOFTENER OF ROUGH STARTS The MCD Soft starter ranging from 7.5 to 800 kw is the optimum solution to a range of

More information

Industry Automation Control Components

Industry Automation Control Components Industry Automation Control Components SIRIUS 3RV2 Motor Starter Protectors SIRIUS 3RV21 Motor Starter Protectors can be easily and flexibly combined with other SIRIUS devices to reduce space requirements

More information

For Operation in the Control Cabinet

For Operation in the Control Cabinet For Operation in the Cabinet 3RW30 for standard applications Overview The SIRIUS 3RW30 soft starters reduce the motor voltage through variable phase control and increase it in ramp-like mode from a selectable

More information

Raising the bar on end-to-end conveyor solutions. SIMOGEAR High-efficiency Geared Motors.

Raising the bar on end-to-end conveyor solutions. SIMOGEAR High-efficiency Geared Motors. Raising the bar on end-to-end conveyor solutions SIMOGEAR High-efficiency Geared Motors www.usa.siemens.com/simogear SIMOGEAR extends the portfolio and expertise of the only automation supplier in the

More information

Starts, stops and protects. Emotron TSA Softstarter

Starts, stops and protects. Emotron TSA Softstarter Starts, stops and protects Emotron TSA Softstarter First in a new line of CG high performance softstarters Emotron TSA softstarters take motor control to a new level. Soft torque starting, intelligent

More information

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter Direct On Line (DOL) Motor Starter Direct Online Motor Starter Different starting methods are employed for starting induction motors because Induction Motor draws more starting current during starting.

More information

Simply the right choice. The latest generation of SIRIUS motor controls: fully optimized for IE3/IE4 motors. siemens.com/sirius

Simply the right choice. The latest generation of SIRIUS motor controls: fully optimized for IE3/IE4 motors. siemens.com/sirius Simply the right choice The latest generation of SIRIUS motor controls: fully optimized for IE3/IE4 motors siemens.com/sirius The EU Directive for IE3 The Directive applies to New motors on the market

More information

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000 .5 00 (mm)hxwxd (Amps) 0x,5x, CSA, A: :0 (AC5b) 5A: 8:0000 0xx8 5A: 65:0080 0xx8 0 T C V Remote operation Series + protection Remote operation of 0, 0 and 00 is facilitated by the dedicated remote operator

More information

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase Siemens AG 2008 3RW Soft Starters Selection and ordering data 28-1BB14 38-1BB14 47-1BB14 Ambient temperature 40 C Ambient temperature 50 C Size DT Order No. Price Rated Rated power of Rated Rated power

More information

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Application example of a motor controlled by MCD100 and protected by a circuit breaker VLT T Soft Start Controller MCD 100 MCD 100 is a cost effective and extremely compact soft starter for AC motors up to 11 kw. Due to a unique semiconductor design MCD 100 is a true fit and forget product.

More information

Game changing soft starters

Game changing soft starters Agile soft starters Low Voltage Soft Starters Game changing soft starters 17 66 A Fire Mode Agile soft starters Soft Stopping Current is limited during soft stopping and gives greater control against water

More information

Just as precise as your motion control application siemens.com/servo-geared-motors

Just as precise as your motion control application siemens.com/servo-geared-motors SIMOTICS S servo geared motors Just as precise as your motion control application siemens.com/servo-geared-motors All components operate together in a coordinated fashion: SIMOTICS S servo geared motors

More information

Sitras SCS, -RCI, -FFP, -TTU

Sitras SCS, -RCI, -FFP, -TTU Sitras SCS, -RCI, -FFP, -TTU control system for traction power supply Remote control interface Frame fault protection Transfer trip unit siemens.com/rail-electrification The Sitras SCS station control

More information

Primary switch mode power supplies CP range

Primary switch mode power supplies CP range Primary switch mode power supplies CP range ABB power supply units: CP range Modern power supply units are a vital component in most areas of energy management and automation technology. ABB as your global

More information

MCD 200 Series Soft Starters

MCD 200 Series Soft Starters MCD 200 Series Soft Starters AC motors often cause one or more serious problems during startup acceleration. MCD 200 Series electronic soft starters control motor current to provide a smooth start. When

More information

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications The XFE Soft Starter range provides a combination of competitive prices, flexible

More information

Versatile. Powerful. Space-saving. siemens.com/et200sp-motorstarter

Versatile. Powerful. Space-saving. siemens.com/et200sp-motorstarter Motor starter SIMATIC ET 200SP Versatile. Powerful. Space-saving. siemens.com/et200sp-motorstarter Optimum protection for your motors and loads The SIMATIC ET 200SP motor starter with its safety and standard

More information

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology VALVE CONTROLLERS Controllers for Dust Extraction 2010 Technology / 2011 Valve controllers for all cases HESCH has the skills and technology to tackle any control task for dedusting of filter and dust

More information

Get on board the drive train. Change now to SIMOGEAR geared motors for easy installation and more flexibility. siemens.

Get on board the drive train. Change now to SIMOGEAR geared motors for easy installation and more flexibility. siemens. Get on board the drive train Change now to SIMOGEAR geared motors for easy installation and more flexibility siemens.com/simogear Contents The portfolio. A perfect fit for every application.... 4 Highest

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

Features and Benefits. Control Features

Features and Benefits. Control Features Features and Benefits AC induction motors have become increasingly dominant in industrial facilities worldwide. Manufacturers faced with increasing pressure to control costs have recognized that motor

More information

Small step, big impact: Energy efficiency and dynamic performance

Small step, big impact: Energy efficiency and dynamic performance Small step, big impact: Energy efficiency and dynamic performance The innovative synchronous-reluctance drive system with SIMOTICS motors and SINAMICS converters A new dimension of efficiency siemens.com/reluctance-drive-system

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

COMPRESSOR SYSTEMS MADE IN GERMANY COMBI SCREW COMPRESSORS

COMPRESSOR SYSTEMS MADE IN GERMANY COMBI SCREW COMPRESSORS COMPRESSOR SYSTEMS MADE IN GERMANY SCREW COMPRESSORS 2 3 About ALMiG QUALITY AND INNOVATIONS MADE IN GERMANY. Decades of experience and excellent performance ALMiG is one of the leading compressed air

More information

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O Data sheet CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus

More information

Sirius IE3/IE4 ready. White Paper January

Sirius IE3/IE4 ready. White Paper January www.siemens.com/ie3ready Sirius IE3/IE4 ready The effects of EU regulations 640/2009 and 04/2014 on the selection and operation of three-phase squirrel cage induction motors in line operation and their

More information

Product brochure. Medium voltage AC drive ACS 2000, 4kV 6.9kV HP

Product brochure. Medium voltage AC drive ACS 2000, 4kV 6.9kV HP Product brochure Medium voltage AC drive ACS 2000, 4kV 6.9kV 300-2000 HP 2 ACS 2000 brochure ABB ACS 2000 simple and reliable motor control The ACS 2000 is the latest member of the ABB medium voltage AC

More information

Variable speed drive or soft starter?

Variable speed drive or soft starter? Hendrik Spies, Product Marketing Manager, May 2013 Variable speed drive or soft starter? 1SFC132018N0201, May 6, 2013 Slide 1 Motor Starter Options May 6, 2013 Slide 2 Motor Starter Options Variable Speed

More information

MAKING MODERN LIVING POSSIBLE. VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500

MAKING MODERN LIVING POSSIBLE. VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500 MAKING MODERN LIVING POSSIBLE VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500 Soft starts Protect gear, goods, equipment and environment An AC motor switched directly on to the mains power supply will

More information

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors Unidrive M600 High performance drive for induction and sensorless permanent magnet motors 0.75 kw - 2.8 MW Heavy Duty (1.0 hp - 4,200 hp) 200 V 400 V 575 V 690 V Unidrive M600 features Easy click-in keypad

More information

For Operation in the Control Cabinet

For Operation in the Control Cabinet As an option the thyristors can also be protected by SITOR semiconductor fuses from short-circuiting so that the soft starter is still functional after a short-circuit (type of coordination ). Three LEDs

More information

A softstarter beyond the ordinary

A softstarter beyond the ordinary A softstarter beyond the ordinary Emotron MSF 2.0 Softstarter More than just Starting an electrical motor involves a number of challenges, such as high start currents and mechanical stress on equipment.

More information

DKR Intelligent Digital AC Vector Drives 35 to 330 hp (26 to 245 kw)

DKR Intelligent Digital AC Vector Drives 35 to 330 hp (26 to 245 kw) Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation DKR Intelligent Digital AC Vector Drives 35 to 330 hp (26 to 245 kw) The Drive &

More information

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443 CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O December 2002 DKACT.PD.C50.G2.02 520B1443 2 DKACT.PD.C50.G2.02 Danfoss A/S 12-2002 Introduction The MCI soft starters

More information

Softstarters Type PSS Type PST/PSTB - New range. New. Catalogue 1SFC132001C0201, Revised in October SFC132016F0201

Softstarters Type PSS Type PST/PSTB - New range. New. Catalogue 1SFC132001C0201, Revised in October SFC132016F0201 Softstarters Type PSS Type PST/PSTB - New range New Catalogue, Revised in October 2003 1SFC132016F0201 Control IT Softstarters Automation Technologies The Automation Technologies division serves customers

More information

The new generation of Brake Testers and Test Lanes: Safe and precise testing. For passenger cars and light commercial vehicles

The new generation of Brake Testers and Test Lanes: Safe and precise testing. For passenger cars and light commercial vehicles The new generation of Brake Testers and Test Lanes: Safe and precise testing For passenger cars and light commercial vehicles Automatic and reliable: Brake tests with the highest possible precision Brake

More information

HIGH-PERFORMANCE MEDIUM VOLTAGE LOAD-COMMUTATED CURRENT SOURCE INVERTER POWER ELECTRONICS FOR INDUSTRIAL APPLICATIONS SISTEMI INDUSTRIALI

HIGH-PERFORMANCE MEDIUM VOLTAGE LOAD-COMMUTATED CURRENT SOURCE INVERTER POWER ELECTRONICS FOR INDUSTRIAL APPLICATIONS SISTEMI INDUSTRIALI HIGH-PERFORMANCE MEDIUM VOLTAGE LOAD-COMMUTATED CURRENT SOURCE INVERTER POWER ELECTRONICS FOR INDUSTRIAL APPLICATIONS SISTEMI INDUSTRIALI Hundreds of installations and more than 30 years of field-proven

More information

The motor starter on the power bus. Solutions for conveyor technology. Full speed ahead

The motor starter on the power bus. Solutions for conveyor technology. Full speed ahead The motor starter on the power bus Solutions for conveyor technology The motor starter on the power bus Full speed ahead The system solution The motor starter on the power bus The motor starter The podis

More information

Automation Days Radionica Motion Control

Automation Days Radionica Motion Control Automation Days 2016 Radionica Motion Control SINAMICS V20 FSAA NEW Up to a power rating of 0.75 kw (line voltage, 1AC, 200 V) now even 24 % smaller and more compact 1 AC 200 V, 0.12 to 0.75 kw with integrated

More information

Industrial Controls. Load Feeder. Configuring SIRIUS Innovations Selection data for Fuseless and Fused Load Feeders. Configuration Manual 04/2011

Industrial Controls. Load Feeder. Configuring SIRIUS Innovations Selection data for Fuseless and Fused Load Feeders. Configuration Manual 04/2011 Load Feeder Selection data for Fuseless and Fused Load Feeders Configuration Manual 04/2011 Industrial Controls Answers for industry. Introduction 1 General information 2 Industrial switchgear Load feeders

More information

ROBICON W120 enclosed drive

ROBICON W120 enclosed drive SINAMICS Drives ROBICON W120 enclosed drive 1 HP to 200 HP Introduction This technical data sheet provides a short overview of the most important characteristics of the ROBICON W120 enclosed standard 6-pulse

More information

SIRIUS Configuration

SIRIUS Configuration SRUS Configuration Selection data for Fuseless Load Feeders Brochure January 2008 www.siemens.com/automation SRUS the Modular System Family for the Switching, rotecting and Starting of s n order to simplify

More information

MGE TM Galaxy TM 7000

MGE TM Galaxy TM 7000 MGE TM Galaxy TM 7000 Power efficiency for business continuity 160/200/250/300/400/500 kva > Performance 3 Phase Power Protection with high adaptability to meet the unique requirements of Medium to Large

More information

The Perfect Fit. Introducing the Next Generation of SINAMICS PERFECT HARMONY GH180 Air-Cooled Drive. usa.siemens.

The Perfect Fit. Introducing the Next Generation of SINAMICS PERFECT HARMONY GH180 Air-Cooled Drive. usa.siemens. The Perfect Fit Introducing the Next Generation of SINAMICS PERFECT HARMONY GH180 Air-Cooled Drive usa.siemens.com/perfectharmony When reliability is all you have room for. When it comes to improving throughput,

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems FUSERBLOC CD The universal Fuse Combination Switch FROM 20 TO 1250 A SOCOMEC GROUP SWITCHING PROTECTION & UPS Industrial Switching & Protection Systems SWITCHING FUSERBLOC CD THE UNIVERSAL FUSE COMBINATION

More information

RVS-AX Instruction Manual

RVS-AX Instruction Manual RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information

Siemens AG SITOP power supply SITOP DC UPS. Solutions for buffering 24 V in the automation. Edition 11/2017. Brochure. siemens.

Siemens AG SITOP power supply SITOP DC UPS. Solutions for buffering 24 V in the automation. Edition 11/2017. Brochure. siemens. power supply DC UPS Solutions for buffering 24 V in the automation Brochure Edition 11/2017 siemens.com/sitop-ups Solutions for bridging power fluctuations and power failures SOLUTIONS Uninterruptible

More information

Start-up instructions

Start-up instructions E l e k t r o n i k s y s t e m e G m b H Development and production of electronical systems Eichelreuth 13 Phone: +49 8641 598360 83224 Grassau Fax: +49 8641 598364 E-Mail: info@rs-steiner.com Internet:

More information

at a reduced size!...

at a reduced size!... Telemecanique Altivar 11 Real efficiency at a reduced size!... Altivar 11 variable speed drives for asynchronous motors from 0.18 to 2.2 kw Building a New Electric World Altivar 11 : The little one with

More information

GEAR UNITS IN FOCUS. PROCESSES UNDER CONTROL.

GEAR UNITS IN FOCUS. PROCESSES UNDER CONTROL. FLENDER SERVICES GEAR UNITS IN FOCUS. PROCESSES UNDER CONTROL. DIAGNOSTEX: sensors, diagnostics, services flender.com DIAGNOSTEX Securing process stability requires condition-based maintenance of the drive

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter The

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 204 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

HYDROVAR IncReAseD flexibility AnD control with new generation

HYDROVAR IncReAseD flexibility AnD control with new generation HYDROVAR Increased flexibility and control with new generation HYDROVAR, the modern variable speed pump drive is taking pumping to a new level of flexibility and efficiency. m Motor or wall mountable m

More information

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are: Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.

More information

The future of soft start motor control at your fingertips

The future of soft start motor control at your fingertips Low Voltage Soft Starters a revolution in soft start motor control The future of soft start motor control at your fingertips a revolution in soft start motor control As the original pioneers of soft start

More information

Reliably Switching Highest Currents up to 2000 A

Reliably Switching Highest Currents up to 2000 A www.moeller.net Reliably Switching Highest Currents up to 2000 A The complete range for the motor circuit. From contactors to efficient motor-starters to controlled drives. New solutions that rely on communication.

More information

Power Supplies. 11/2 Introduction

Power Supplies. 11/2 Introduction Siemens AG 2009 Power Supplies 11 11/2 Introduction 4AV Non-Stabilized Power Supplies Filtered for Supply of Electronic Controls 11/4 General data 11/5 4AV2, 4AV4 power supplies, filtered, single-phase

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements

More information

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control Selection Guide for SMC-Delta and SMC-3 A New Dimension in Motor Control Discover a New Dimension in Motor Control: SMC-Delta and SMC-3 The Allen-Bradley SMC-Delta and SMC-3 softstarters from Complete

More information

EMX3 SOFT STARTER. Take control from the start

EMX3 SOFT STARTER. Take control from the start EMX3 SOFT STARTER Take control from the start The EMX3 is a comprehensive motor management system for the most demanding soft starting and stopping applications. With an impressive range of features, the

More information

Dynamic PFC:Thyristor Modules TSM Series

Dynamic PFC:Thyristor Modules TSM Series Dynamic PFC:Thyristor Modules TSM Series P o w e r Q u a l i t y S o l u t i o n s www.epcos.com/pfc The collection of PQS is a library with in-depth information on PFC applications, case studies and reference

More information

The comprehensive portfolio of the testing laboratories at Schaltwerk Berlin siemens.com/energy/psw

The comprehensive portfolio of the testing laboratories at Schaltwerk Berlin siemens.com/energy/psw Powerful, efficient, independent The comprehensive portfolio of the testing laboratories at Schaltwerk Berlin siemens.com/energy/psw Outstanding testing expertise and always up to date Benefit from decades

More information

Pitch Systems. Siemens AG All Rights Reserved.

Pitch Systems. Siemens AG All Rights Reserved. Pitch Systems Motion Control Equipment for Wind SINAMICS Pitch & Yaw Solutions SINAMICS Pitch Solutions Application Positioning of rotor blades at perfect angle Dynamic operation depending on Wind speed

More information

SIRIUS 3RW5 Soft Starters

SIRIUS 3RW5 Soft Starters SIRIUS 3RW5 Soft Starters As versatile as yor application siemens.com/softstarter3rw5 SIRIUS 3RW Soft Starters matches the versatility of yor individal challenges in fixed speed applications Pmping Ventilating

More information

Demag KB conical-rotor brake motors. Drives with unique principle

Demag KB conical-rotor brake motors. Drives with unique principle Demag KB conical-rotor brake motors Drives with unique principle 37468 Demag KB conical rotor brake motors: Demag KB conical rotor brake motors offered by Demag Cranes & Components feature a unique principle:

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The new device category! The PowerXL DE1 Variable Speed Starter The PowerXL DE1 Variable Speed Starter one device, all the advantages

More information

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry. Protection Equipment Overload Relays Reference Manual 04/2011 Industrial Controls Answers for industry. Protection Equipment 2 3 7 7 8 9 14 1 16 17 18 18 19 20 2 26 27 28 29 30 32 37 38 40 42 Introduction

More information

Start-up instructions

Start-up instructions E l e k t r o n i k s y s t e m e G m b H Development and production of electronical systems Eichelreuth 13 Phone: +49 8641 598360 83224 Grassau Fax: +49 8641 598364 E-Mail: info@rs-steiner.com Internet:

More information

a revolution in soft start motor control The future of soft start motor control at your fingertips

a revolution in soft start motor control The future of soft start motor control at your fingertips The future of soft start motor control at your fingertips As the original pioneers of soft start technology Fairford have been at the forefront of motor control innovation since the 1970 s. A major designer

More information

Drive technology for the chemical industry. chemical INDUSTRY

Drive technology for the chemical industry. chemical INDUSTRY Drive technology for the chemical industry chemical INDUSTRY More so than in other industrial sectors, drive and automation systems in the chemical industry must comply with the strictest safety standards

More information

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DEVICE STATE/BYPASSED FAILURE OVERLOAD Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated

More information

Spectrum PowerCC DM Distribution Management The control system for distribution network operators

Spectrum PowerCC DM Distribution Management The control system for distribution network operators Spectrum PowerCC DM Distribution Management The control system for distribution network operators Power Transmission and Distribution A glance at today s IT world shows that systems are becoming ever more

More information

Standard Features 200-600V, 50/60Hz input power supply Built-in run rated (AC1) By-pass contactor up to 820 A * Rated 450% current Conformal coated circuit board Voltage ramp or current limit start modes

More information

SIMOTICS FD looks different, offers more

SIMOTICS FD looks different, offers more SIMOTICS FD looks different, offers more The new definition of the asynchronous motor siemens.com/simotics-fd siemens.com Power, flexibility and efficiency redefined A motor is not always a motor. The

More information

ABB Softstarters The new PSS line from 3A to 515A

ABB Softstarters The new PSS line from 3A to 515A The new PSS line from 3A to 515A AC 1061 Low Voltage Products & Systems the easy solution that will save you time and money Starting a motor across the line or through a wye-delta starter can result in

More information

SOLSTART Instruction Manual

SOLSTART Instruction Manual Solstart Analog Soft Starter 8-58A, 220-600V Instruction Manual Ver. 23/03/2009 2 Table of Content SOLSTART Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information