DUCT & FITTINGS. Straight Duct WITH ANGLE RINGS (AVAILABLE ) "L" STANDARD LENGTHS("L") DIAMETER "L" 100 TO TO
|
|
- Shannon Charles
- 6 years ago
- Views:
Transcription
1 DUCT & FITTINGS Straight Duct OPTIONS: Custom lengths available. Duct greater than 2100 diameter requires Uangyih-tech Engineering review and approval. Refer to Uangyih-tech Flanges System section for adapters, drains and test port aw end available. SP duct. Type no. PUDTPA (AVAILABLE ) "D" "L" STANDARD LENGTHS("L") DIAMETER "L" 100 TO TO
2 DUCT & FITTINGS Straight Duct with Straight Tap OPTIONS: Custom lengths available. Duct greater than 2100 diameter requires Uangyih-tech Engineering review and approval. Multiple and offset taps available aw end available. SP duct. (AVAILABLE ) Type no. PUSTPA *MIN DISTANCE TO DUCT END = : 50mm MIN = : 100mm MIN *50mm MIN "D2" *50mm MIN "L3" 150mm STD STANDARD LENGHTS ("L") DIAMETER "L" 100 TO TO STRAIGHT TAP MIN = "D2"+100mm MAX = 2400mm "D2" MAX = 2200
3 DUCT & FITTINGS Straight Duct with Conical Tap OPTIONS: Custom lengths available. Duct greater than 2100 diameter requires Uangyih-tech Engineering review and approval. Multiple and offset taps available aw end available. SP duct. (AVAILABLE ) *MIN DISTANCE TO DUCT END = : 75mm MIN = : 125mm MIN *75mm MIN "D2" *75mm MIN Type no. PUCTPA "L3" 150mm STD 25mm STD 25mm STD STANDARD LENGHTS ("L") DIAMETER "L" 100 TO TO CONICAL TAP MIN = "D2"+150mm MAX = 2400mm "D2" MAX = 2150
4 DUCT & FITTINGS OPTIONS: Custom lengths available. Straight Duct with Shoe Tap Duct greater than 2100 diameter requires Uangyih-tech Engineering review and approval. Multiple and offset taps available aw end available. SP duct. ot coated duct. (AVAILABLE ) Type no. PUHTPA *MIN DISTANCE TO DUCT END = : 75mm MIN = : 125mm MIN *75mm MIN "D2" *75mm MIN 100mm STD 45 "L3" 150mm STD STANDARD LENGHTS ("L") DIAMETER "L" 100 TO TO Shoe TAP MIN = "D2"+100mm(Shoe length)+150mm MAX = 2400mm "D2" MAX = 2150
5 OPTIONS: Custom lengths available. **L2 MIN DISTANCE = : 100mm MIN = :175mm MIN DUCT & FITTINGS Straight Duct with Lateral Tap Duct greater than 2100 diameter requires Uangyih-tech Engineering review and approval. Multiple and offset taps available aw end available. SP duct. (AVAILABLE ) **100mm MIN "L3" *150mm MIN "D2" Type no. PUYTPA *MIN LENGTH FOR "L3" AND "L4" "L3" "L4" mm MIN 100mm MIN mm MIN 100mm MIN mm MIN 125mm MIN mm MIN 150mm MIN "L4" *100mm MIN STANDARD LENGHTS ("L") DIAMETER "L" 100 TO TO LATERAL TAP MIN = ("D2" x )+100mm+"L4" MAX = 2400mm "D2" MAX = 1500
6 OPTIONS: Standard gores and radii are shown, custom number of gores, custom radii, and throat extensions are available. DUCT & FITTINGS Gored Elbow Duct greater than 2100 diameter requires Uangyih-tech Engineering review and approval. PSP duct. SF1 90 ELBOW (AVAILABLE ) "D" 5 GORE DUE TO MANUFACTURING LIMITATIONS, THE FOLLOWING FULL RADIUS ELBOWS ARE NOT AVAILABLE: R 90 ELBOW GREATER THAN 1500 DIA. 60 ELBOW GREATER THAN 2050 DIA. 45 ELBOW GREATER THAN 2650 DIA. Type no. PUE9PA SF2 STANDARD RADIUS AT THE DUCT CENTERLINE "R" = 1.5 x "D" OR "R"= 1 x "D" LARGE ELBOWS ABOVE THESE LIMITS WILL BE MANUFACTURED AS SMALLER FITTINGS. EXAMPLE:AN 2150 DIA. 90 ELBOW WILL BE SUPPLIED AS TWO 45 ELBOWS SF1 4 GORE SF1 3 GORE SF1 2 GORE Type no. PUE6PA 60 ELBOW SF2 Type no. PUE4PA 45 ELBOW Uangyih-tech Standard DIAMETER R = 1 x D R= 1.5 x D SF1=25 SF2=25 SF1=0 SF2= SF1=20 SF2=20 SF1=0 SF2=0 550 UP SF1=0 SF2=0 SF2=0 SF2=0 SF2 Type no. PUE3PA 30 ELBOW 1/2 RADIUS ELBOWS ARE NOT AVAILABLE. SF2
7 DUCT & FITTINGS Concentric and Eccentric Reducer OPTIONS: Custom length available. PSP duct. (AVAILABLE ) Type no. PUERPA Type no. PUCRPA "L3" "D2" "D2" "L4" "L5" ECCENTRIC Formula to calculate the minmum length for an eccentric reducer =+"L4"+"L5" Use this chart for minimum length of (Shorter taper or length can be fabricated, but will effect air flow) AMOUNT OF REDUCTION MINMUN LINGTH minus "D2" 150 AND LESS 300 mm 175 TO mm 250 TO mm 350 TO mm Use this chart for minimum length of "L4" & "L5" MINMUN DUCT DIAMETER LINGTH or "D2" "L4" or "L5" 100 TO mm 1500 TO mm 2400 TO mm "L4" "L5" CONCENTRIC Formula to calculate the minmum length for an concentric reducer =+"L4"+"L5" Use this chart for minimum length of (Shorter taper or length can be fabricated, but will effect air flow) AMOUNT OF REDUCTION MINMUN LINGTH minus "D2" 225 AND LESS 300 mm 250 TO mm 375 TO mm 500 TO mm Use this chart for minmum length of "L4" & "L5" DUCT DIAMETER MINMUN LINGTH or "D2" "L4" or "L5" 100 TO mm 1500 TO mm 2400 TO mm
8 DUCT & FITTINGS Offset OPTIONS: Custom length available. PSP duct. (AVAILABLE ) Type no. PUOFPA "D2"
9 RECTANGULAR DUCT Concentric Round to Rectangular Transition OPTIONS: PSP duct. (AVAILABLE ) NOTES: RAW END ABAILABLE. Type no. PUFCRPA OUND DUCT GREATER THAN 2100mm DIAMETER REQUIRES UANGYIH-TECH ENGINEERING REVIEW AND APPROVAL. ECTANGULAR DUCT WIDTH OR HEIGHT OF 2450mm AND LARGER REQUIRES UANGYIH-TECH ENGINEERING REVIEW. "X" "Y" "D" FOR ECCENTRIC ROUND TO RECTANGULAR FITTING, USE THE CUSTOM FITTING ORDER SHEET.
10 CONTROL DEVICES Custom Fitting 90 DEGREE REDUCING TEE 90 DEGREE WYE ELBOW WITH HEEL TAP ECCENTRIC ROUND TO RECTANGULAR TRASITION
11 CONTROL DEVICES Industrial Single Blade Balancing Damper SPECIFICATIONS Floating ring - stainless steel Manual actuation PP edge seal, Welded blade stop, Liquid tight axle seals OPTIONS Custom hole pattern Electric / pneumatic actuators PSP duct. Type no. PUDHPA DIAMETER BLADE BODY 100 TO t 1.0t 350 TO t 2.0t 235mm STD PP EDGE SEAL "D" 75mm
12 CONTROL DEVICES Micro Adjustable Damper Option FOR INDUSTRIAL SINGLE BLADE BALANCING OPTIONS: PSP duct. POSITION INDICATOR LOCKOUT FEATURE COUNTER CLOCKWISE TO OPEN ACTUATOR WHEEL Type no. PUDZPA REV:10/12/09
13 CONTROL DEVICE Heavy Duct industrial Single Blade Damper SPECIFICAIONS welded stainless steel rings float stainless steel rings. Mounting holes straddle vertical centerline. Lliquid tight shaft seals-thermoplastic sleeve bearings. 35mm stainless steel axles TO mm stainless steel blade, 350 TO 950 4mm stainless steel blade. OPTIONS Pneumatic actuator. COUNTER CLOCKWISE TO OPEN Electric actuator. Custom hole pattern. PSP duct. DIAMETER BLADE BODY t 2.0t t 3.0t Type no. PUDBZPA (AVAILABLE ) 250mm STD "D" POSITION INDICATOR BLADE STOP
14 SPECIFICAIONS welded stainless steel rings float stainless steel rings. CONTROL DEVICE Heavy Duct industrial Sealed Bearing Single Blade Damper Mounting holes straddle vertical centerline. Lliquid tight shaft seals-thermoplastic sleeve bearings. 35mm stainless steel axles - 6mm stainlee steel blade. Welded blade stops with seal. COUNTER CLOCKWISE TO OPEN OPTIONS Pneumatic actuator. Electric actuator. Custom hole pattern. PSP duct. DIAMETER BLADE BODY t 2.0t t 2.0t t 3.0t Type no. PUDAZPA (AVAILABLE ) 250mm STD "D"
15
16 SPECIFICAIONS FRAME 200mm STANDARD LENGTH WITH 50mm FLANGES - 3mm STAINLESS STEEL CENTER SUPPORT AS REQUIRED. MOUNTING HOLES (12 x 18 SLOT) LOCATED BETWEEN 75mm To 102mm ON CENTER. BLADES - 3mm STAINLESS STEEL. AXLES - 20mm DIAMETER STAINLESS STEEL. CONTROL DEVICE Heavy Duty Rectangular Parallel Blade Control Damper LIQUID TIHGT SHAFT SEALS. OPTIONS PNEUMATIC / ELECTRIC ACTUATOR. GEAR DRIVE. Type no. PUFDZPA CENTER SUPPORT REQUIRED FOR BLADES LONGER THAN 1200mm () 200mm STD Heavy Duty Rectangular Opposed Blade Control Damper SPECIFICAIONS FRAME 200mm STANDARD LENGTH WITH 50mm FLANGES - 3mm STAINLESS STEEL CENTER SUPPORT AS REQUIRED. MOUNTING HOLES (12 x 18 SLOT) EQUAL TO OR LESS THAN 102mm ON CENTER. BLADES - 2.0mm STAINLESS STEEL. AXLES - 20mm STAINLESS STEEL. LIQUID TIHGT SHAFT SEALS. OPTIONS PNEUMATIC / ELECTRIC ACTUATOR. GEAR DRIVE. Type no. PUFDOZPA 200mm STD & DISTANCE MIN = 500mm MIN = 500mm CENTER SUPPORT REQUIRED FOR BLADES LONGER THAN 1200mm ()
17 CONTROL DEVICE SPECIFICAIONS FRAME 200mm STANDARD LENGTH WITH 50mm FLANGES - 3mm STAINLESS STEEL CENTER SUPPORT AS REQUIRED. FLANGE MOUNTING HOLES (12 x 18 SLOT) EQUAL TO OR LESS THAN 102 ON CENTER. BLADES - 1.5mm STAINLESS STEEL. AXLES - 20mm DIAMETER STAINLESS STEEL. Heavy Duty Rectangular Industrial Backdraft Damper 200mm STD LIQUID TIHGT SHAFT SEALS. MANUAL ADJUSTABLE COUNTERWEIGHTS. Type no. PFDCPA COUNTERWEIGHT CENTER SUPPORT REQUIRED FOR BLADES LONGER THAN 1200mm ()
18 CONTROL DEVICE Heavy Duty Rectangular Industrial Fire Damper SPECIFICAIONS FRAME 250mm STANDARD LENGTH WITH 50mm FLANGES - 3mm STAINLESS STEEL. FLANGE MOUNTING HOLES (12 x 18 SLOT) EQUAL TO OR LESS THAN 102 ON CENTER. BLADES - 2.0mm STAINLESS STEEL. AXLES - 13mm DIAMETER STAINLESS STEEL. LIQUID TIHGT SHAFT SEALS. MANUAL ADJUSTABLE COUNTERWEIGHTS. Type no. PFD-M 250mm STD & DISTANCE & MIN = 200mm & MAX= 700mm
PermaShield Pipe. Fab-Tech, Inc. PRODUCT CATALOG. Stainless Steel Corrosive Fume Exhaust Systems With PermaShield Fluoropolymer Barrier Coating
PermaShield Pipe C Stainless Steel Corrosive Fume Exhaust Systems With PermaShield Fluoropolymer Barrier Coating PRO CATALOG Catalog 10/12.8 Fab-Tech, Inc. A Critical Process Systems Group Company CONTENTS
More informationPermaShield Pipe ROUND DUCT ORDER COVER SHEET. Stainless Steel Corrosive Fume Exhaust Systems With PermaShield Fluoropolymer Barrier Coating
PermaShield Pipe Stainless Steel Corrosive Fume Exhaust Systems With PermaShield Fluoropolymer Barrier Coating ROUND ORDER COVER SHEET Catalog 10/12.8 COMPANY: PROJECT MGR.: MAILING ADDRESS: PHONE NO.:
More informationSECTION 1 Grooved Fittings
Anvil offers two different sets of stainless steel fittings. The Gruvlok Series Fittings have full flow designs formed from type 304SS pipe. The Schedule 10 fittings are fabricated from segmentally welded
More informationPVC SUPERDUCT PIPE PVC SUPERDUCT FITTINGS
HRRISON MCHINE & PLSTIC CORPORTION PVC SUPERDUCT PIPE PVC SUPERDUCT FITTINGS For Harrison Fume Exhaust Systems Dimensions Catalog 1 HRRISON MCHINE & PLSTIC CORPORTION 11614 ST. RT. 88 GRRETTSVILLE, OH
More informationINDEX. Chapter1 6. air master. Volume Control Dampers
Chapter1 6 INDEX 1 Volume control damper...:avcd...16.1 Standard sizes...16.2 Fixing details...16.2 How to order...16.2 Performance chart...16.3 2. Circular volume control damper....:avcd-c....16.4 Standard
More informationSheet Metal Connectors, Inc Main Street N.E. Minneapolis, Minnesota
Sheet Metal Connectors, Inc. 5850 Main Street N.E. Minneapolis, Minnesota 55432-5439 Sheet Metal Connectors, Inc. www.smcduct.com SPECIFICATIONS FOR SPIRAL PIPE AND FITTINGS MINNEAPOLIS, MN 5850 Main Street
More informationHCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.
Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety
More informationCPVC DUCT PIPE & FITTINGS
CPVC DUCT PIPE & FITTINGS For Harrison Fume Exhaust Systems HRRISON MCHINE & PLSTIC CORPORTION Dimensions Catalog 1 HRRISON MCHINE & PLSTIC CORPORTION 11614 ST. RT. 88 GRRETTSVILLE, OH Table of Contents
More informationManufacturing Facilities. Sheet Metal Connectors, Inc. is proud to be a member or affiliated with the following associations;
Corporate Headquarters SHEET METL CONNECTORS, INC. 5850 MIN STREET N.E. MINNEPOLIS, MINNESOT 55432 Toll Free: 800-328-1966 Local: 763-572-0000 Fax: 763-572-1100 www.smcduct.com Manufacturing Facilities
More informationHCD-230 Industrial Control Damper
Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety
More informationIMPACT IMPEX PTFE, PFA, PVDF, PP LINED PIPE & FITTINGS. ANSI # 150.
IMPACT IMPEX PTFE, PFA, PVDF, PP LINED PIPE & FITTINGS.. The information contained in this publication is intended as a guide to customers, and is freely given in good faith. Whilst every care has been
More informationARROW INDUSTRIAL PRODUCTS
IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products
More informationBlower Specifications
Lab These charts are arranged by increasing CFM. All lab blowers are 0Hz. See the preceding Four Steps To Blower Selection. 0 to CFM to / inch Static Pressure SIZE CODES -000/00 / () 0-00 / /0-0 () 0-000
More informationWhen Time is Everything... We Manufacture in Days - Not Weeks!
When Time is Everything... We Manufacture in Days - Not Weeks! DAMPERS ACCESS DOORS LOUVERS July 2014 Specializing In Products For The HVAC Industry 763-783-7173 fax: 763-785-6977 1-800-297-9360 Customer:
More informationARROW UNITED INDUSTRIES
IP-3R ARROW UNITED INDUSTRIES Building Tomorrow s Ventilation Today Heavy Duty Dampers Industrial, Power Plant & Commercial Applications ARROW UNITED INDUSTRIES has specialized in the design and manufacturing
More informationINLET BOXES AND INLET-BOX DAMPERS
INLET BOXES AND INLET-BOX DAMPERS Available on these Arrangement 1, 4, 8, 9, 9F, and 10 fans: GENERAL PURPOSE FANS ACOUSTAFOIL/PLR FANS CLASS IV FANS AF FANS RTS FANS GI FANS HPBC FANS BC FANS BCPB FANS
More informationDUST, FUME, TRIM & WASTE REMOVAL
METFLO DUCT COMPONENTS DUST, FUME, TRIM & WASTE REMOVAL H-P Products, Inc. 800.860.TUBE (8823) Fax: 330.875.7155 www.metflo.com 1 Services INDEX SERVICES.... 2 SPECIAL PARTS.... 3 ROLLED LIP DUCT Straight
More informationVOLUME CONTROL DAMPERS
VOLUME CONTROL DAMPERS CONSTRUCTION FEATURES FRAME Roll formed 16 gauge galvanized steel channel with welded corners. X-Standard, Z-optional AXLES Roll formed 18 gauge galvanized steel. 1/2" Round chrome
More informationDAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING
PUB. NO. 732-3 DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING The most widely used dampers in commercial HVAC applications Control Dampers - Extruded Aluminum
More informationAL-Maraj Central A/C Systems Accessories Mfg Co.
AL-Maraj is one of the renowned Manufacturer, Stockist and Supplier of all kinds of HVAC products, Ducting accessories, Pipe support system, Electro-mechanical and A/C Accessories in U.A.E since 2000.
More informationTURBO PRESSURE BLOWERS
Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TURBO PRESSURE BLOWERS TBA TBR CATALOG 10 APRIL 13 TURBO PRESSURE BLOWERS Models TBA TBR TBR Arrangement 8 Model TBA and TBR fans from
More informationL O U V E R S & D A M P E R S
L O U V E R S & D A M P E R S www.alggin.com CALGARY EDMONTON LETHBRIDGE 4540-46th Ave. SE 12110-154 St. NW 1126-36 St. N (403) 252-0132 (780) 424-0132 (403) 320-8732 sales@alggin.com edmsales@alggin.com
More informationGrooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 60"/1500 in a variety of straight and reducing styles. Most standard fittings are cast of durable
More informationGrooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 60"/1500 in a variety of straight and reducing styles. Most standard fittings are cast of durable
More informationFusible Link (replaceable) Horizontal Mount
Application Model FD-50 is a static rated fire damper approved for use in walls and partitions with fire resistance ratings less than hours. This model carries a /2 hour UL fire damper label. UL 555 classifies
More informationPRODUCT INDEX PRODUCT INDEX. Item Page Item Page Item Page
PRODUCT CATALOG PRODUCT INDEX Item Page Item Page Item Page PRODUCT INDEX 001 Flat 45 Duct Angle 11 002 Flat 90 Duct Elbow 11 003 Vertical 45 Duct Angle 11 004 Vertical 90 Duct Elbow 11 005 Duct End Cap
More informationNEW PRODUCTS HRANEC SHEET METAL INTRODUCES. FOR 2015! Call for. Pricing S P I R A L & O V A L M A N
HRANEC 724-437-2211 SHEET METAL INTRODUCES 2 NEW PRODUCTS Roof Ports systems are stocked for same day shipping, see page 4. FOR 2015! Call for Pricing O V A L M A N 724-437-2211 Made to order single wall
More informationModel DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features
Application Model is approved for use in walls, floors, and partitions with fire resistance ratings less than 3 hours. This model carries a 1 1 2 hour UL fire damper label. UL555 classifies dynamic rated
More informationTable of Contents. Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 4 Page 4 Page 5 Page 5 Page 5
-02 - Location and Mounting: AirflowMonitoringStation Table of Contents #1 - Right Angle wo/turning Vanes Mounting #2 - Right Angle w/turning Vanes Mounting #3 - Right Angle w/rounded Elbow Mounting #4
More informationModel DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features
Application Model is approved for use in walls, floors, and partitions with fire resistance ratings less than 3 hours. This model carries a 1 1 2 hour UL fire damper label. UL555 classifies dynamic rated
More informationORDER SIZE A B
90 DEGREE SADDLE ORDER SIZE A B 3 26 4 26 5 26 6 26 8 26 10 26 12 26 14 26 16 26 18 26 Commercial designed to meet SMACNA Duct Construction Standards. Maximum W.G. is 2-4. All 90 Degree Saddles are made
More informationLINEAR DIFFUSERS AND BAR GRILLES
LINEAR DIFFUSERS AND AR GRILLES LINEAR DIFFUSERS AND AR GRILLES LINEAR SLOT DIFFUSER PLENUMS FOR TECHZONE TYPE CEILINGS Model Series 5300TZ Plenums are designed to fit the 5000TZ Series Slot Diffusers.
More informationSeries HCD Airfoil Control Damper
Series HCD Airfoil Control Damper Model: HCD-1 The Holyoake HCD-1 is a precisely made volume and pressure control device with extremely low leakage when closed, (in the range of 0.003m 3 /s at 100 Pa).
More informationM Remote Mounting Kit
M9203-250 Remote Mounting Kit Installation Instructions M9203-250 Part No. 34-636-2324, Rev. Issued July 6, 2011 Applications The M9203-250 Remote Mounting Kit enables the M9203 Series Electric Spring
More informationModel DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features
Application Model is approved for use in walls, floors, and partitions with fire resistance ratings of hours or more. This model carries a hour UL fire damper label. UL 555 classifies dynamic rated fire
More informationM Damper Mount Linkage Kit Installation. Item Description Quantity Item Description Quantity Nuts 2
FANs 268.1, 1628.3 Installation Bulletin M9000-150 Issue Date 0796 M9000-150 Damper Mount Linkage Kit Installation 21 18 19 20 2 22 17 2 4 3 2 15.5 393.7 1 17 16 15 11 13 12 8 9 10 2 5 Note: Damper mount
More informationDC Duct & Sheet Metal LLC Office: 2520 Pennsylvania Avenue, SE Washington, DC 20020
SHEET METAL WORKERS LOCAL 100 Office: 2520 Pennsylvania Avenue, SE Washington, DC 20020 Shop: 3711 Wells Avenue Mount Rainier, MD 20712 Spiral Duct Material Options Our products are fabricated from a variety
More informationDefining Innovation. turbo pressure blowers. Twin City Catalog 1200
Defining Innovation. turbo pressure blowers MODEL TBA TBR 1 Twin City Catalog CATALOG -A May 11 Model TBA/TBR Turbo Pressure Blowers Model TBA and TBR fans from Twin City Fan & Blower are constant pressure,
More informationGrooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 60"/1500 in a variety of straight and reducing styles. Most standard fittings are cast of durable
More informationSincerely, Your Partners at Specified Fittings
N E S E S Washington Location 14 W. Smith Rd. Bellingham, WA 9822-91 30-398-00 30-398-051 Fax Mailing Address Montana Location 483 Airport Rd. Stevensville, MT 5980-33 40--34 40--181 Fax Mexico PO Box
More informationA Complete Line of Quality Products for Marine Applications
american warming and ventilating A Mestek Company A Complete Line of Quality Products for Marine Applications 1 About AWV Marine Dampers At American Warming and Ventilating, we are committed to design
More informationSECURITY PRODUCTS SECURITY PRODUCTS
GRILLES & REGISTERS These louvered blade grilles and registers are paired up with a lattice face plate to meet minimum security requirements. They are available for both supply and return air applications
More informationVCD-23. Flange Options. Size Limitations
Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators
More informationSECTION 5 AMERICAN. Ductile Iron Mechanical Joint Fittings
ECION 5 AMERICAN Ductile Iron Mechanical Joint Fittings he principal standards covering full body mechanical joint fittings are ANI/AWWA C110/A21.10 and ANI/AWWA C111/A21.11. Compact ductile iron fittings
More informationAirflex Air Ride Suspension System Installation Instructions
www.dexteraxle.com Airflex Air Ride Suspension System Installation Instructions Frame Styles Tube Frame Outside Frame Dimension Outside Bracket Dimension Channel Frame Outside Frame Dimension "C" Channel
More informationPRODUCT FEATURES & BENEFITS
Product Features & Benefits PRODUCT FEATURES & BENEFITS 1105 Seam Welded Elbows: Seam welds add strength to the gores Seam welds eliminate meat hooks Easy to adjust FasFit Airtite Take Offs: Feature airtight
More informationALUMINUM DISTRIBUTING, INC S.W. 2nd Ave. Ft. Lauderdale, FL Table of Contents
Table of Contents Page 2.........Equal & Unequal Angle Structural & Architectural Page 3.......................Flat Bar Structural Page 4.....................Flat Bar Architectural Page 5..... U Channel,
More informationFusible Link (replaceable) Horizontal Mount
Application Model SSFD-50 is a static rated fire damper approved for use in walls and partitions with fire resistance ratings less than hours. This model carries a 2 hour UL fire damper label. UL555 classifies
More informationPermaShield Pipe. Fab-Tech, Inc. INSTALLATION AND ASSEMBLY GUIDE
PermaShield Pipe Stainless Steel Corrosive Fume Exhaust Systems With PermaShield Fluoropolymer Barrier Coating INSTALLATION AND ASSEMBLY GUIDE Catalog 10/12.8 Fab-Tech, Inc. A Critical Process Systems
More informationDuct systems. Steel duct Galvanized. Ext. dia. mm. Length m. Material thickness mm
teel duct Galvanized Ext. dia. m Material thickness 050 3 m 1,25 4,5 590105003 063 3 m 1,25 5,8 590106303 076 3 m 1,50 8,3 590105003 102 3 m 1,50 11,1 590110203 108 3 m 1,50 11,8 590110803 127 3 m 1,50
More informationInstallation Instructions
34-636- 2286, Rev. C (barcode for factory use only) M9000-400 Jackshaft Linkage Kit Installation Instructions M9000-400 Part No. 34-636-2286, Rev. C Issued June 2017 Applications Refer to the QuickLIT
More informationWDD/WSD - Grille. Halton WDD/WSD. Universal Grille
Halton WDD/WSD Universal Grille Horizontal air supply, suitable also for exhaust Adjustable vertical front vanes, adjustable horizontal rear vanes: WDD, adjustable horizontal vanes: WSD Aluminium construction
More informationGastight Rectangular Shut-Off Damper, Type GD-R
Page 1/7 Page 2/7 Gastight Shut-Off System Gastight Rectangular Shut-Off Damper, Components such as damper systems used in ventilation systems for sensitive areas, like the chemical, the pharmaceutical
More informationCONTROL SMOKE AND BALANCING DAMPERS
(UK) Limited CONTROL SMOKE AND BALANCING DAMPERS 00 SERIES - UNIVERSAL F e a t u r e s Robust construction of galvanised steel, with stainless steel options Opposed or parallel blade pattern Unsealed,
More informationSection 2. Shurjoint Grooved Fittings Flow Data / Friction Resistance Ductile Iron Grooved Fittings. Wrought Grooved Fittings
Section 2 Cast & Wrought Grooved Fittings Shurjoint Grooved Fittings... 56 Flow Data / Friction Resistance... 56 Ductile Iron Grooved Fittings 7110 / 7111 / 7112 / 7113 Elbows... 57 7120 / 7135 / 7130
More informationPERFORMANCE AND SPECIFICATION. BORING DIAMETER RANGE 1.5 to 24 BORING BAR STROKE 305, 610 or 915mm 12, 24, or 36
MLB610 Line Boring Machine Rev 1.0 Page 1 of 9 DESCRIPTION A versatile and modular line boring machine offering a choice of electric, hydraulic and pneumatic boring bar drive motors, with a mechanical
More informationHole-cutting. cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8 (16mm) of the hole
Mechanical Tees Hole-cutting Shurjoint mechanical tees provide a fast and easy mid-point branch outlet, eliminating the need for welding or the use of multiple fittings. The Model M21 features a female
More informationMODEL B HYDRAULIC PUMP
< < SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.powerteam.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031
More informationParts list ErgoStrap 600E Frame - Cutter - Strap lifter
Parts list ErgoStrap 600E Frame - Cutter - Strap lifter Item Quantity Unit Designation Art. No. 1.1 1 ea. Frame with storage compartment (without attachement parts) 600 E 600332 1.2 2 ea. Large wheels
More informationGrooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 48 /1200 in a variety of straight and reducing styles. Most standard fittings are cast of durable
More information- METALLIC EXPANSION JOINTS
EXPANSION JOINTS FOR PIPING SYSTEM - METALLIC EXPANSION JOINTS - NON METALLIC EXPANSION JOINTS EXPANSION JOINTS FOR PIPING SYSTEM - METALLIC EXPANSION JOINTS - NON METALLIC EXPANSION JOINTS - EXPANSION
More informationBritish Standard institute-bs Valve Standards
BS 341-1:1991 Transportable gas container valves. Specification for industrial valves for working pressures up to and including 300 bar (REPLACED by BS EN 14189:2003), BS 341-3:2002), BS EN 849:1997),
More informationModel VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.
Application and Design The series is a vertical blade general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium
More informationGRUVLOK FITTINGS FOR GROOVED-END PIPE
GRUVLOK FITTINGS FOR GROOVED-END PIPE Gruvlok fittings are available through 24" nominal pipe size in a variety of styles. Use the Fitting Table to convert nominal pipe size to corresponding pipe These
More informationSmoke Dampers. Installation Instructions
Smoke Dampers Installation Instructions Installation Details 1. Dampers should be installed to provide proper operation and performance. They should be installed to permit them to maintain their shape
More informationPositive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS
BACKDRAFT DAMPERS BLADE OPTION: SR: 0.016-0.020 roll formed aluminum with vinyl gasket - used with fan motors under 1 HP SE: 0.05 extruded aluminum with vinyl gasket - used with fan motors over 1 HP Positive
More informationJVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6
1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 2 VAV regulator, model Description The variable air volume regulators
More informationManufacturing Facilities. Sheet Metal Connectors, Inc. is proud to be a member or affiliated with the following associations;
Corporate Headquarters SHEET METAL CONNECTORS, INC. 5850 MAIN STREET N.E. MINNEAPOLIS, MINNESOTA 55432 Toll Free: 800-328-1966 Local: 763-572-0000 Fax: 763-572-1100 www.smcduct.com Manufacturing Facilities
More informationModel VCD-20 3V CONTROL DAMPER
R Application and Design The series is a ruggedly built general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium
More informationInstruction Manual for HSPA Take-Up Units
Installation Instruction Manual for HSPA Take-Up Units Warning: To ensure the drive is not unexpectedly started, turn off and lockout the power source before proceeding. Failure to observe these precautions
More information.2016 P R,o 01u1cT C.ATALQ,G KB Duct. A CECO Environmental Brand
.2016 P R,o 01u1cT C.ATALQ,G - - ---------- KB Duct A CECO Environmental Brand KB Duct is a true pioneer in the industrial ductwork market. Since 1907, Kirk & Blum has been the nation s largest manufacturer
More informationFSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 FSD60, FSD60LP CoMINAtIoN FIRe AND SMoKe DAMPeR 1 1 /2 HoUR UL555 RAteD, UL555S LeAKAge CLASS 1 APPLICAtIoN Ruskin FSD60 Series
More informationB. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.
PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationA Zy-Tech Global Industries Product
A Zy-Tech Global Industries Product Worm & evel Gear Operators Another quality product from Zy-Tech Global Industries, Inc. Zy-Gear gear operators are designed for long lasting dependable service in oil
More informationMODEL B ELECTRIC HYDRAULIC PUMP
SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.powerteam.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031
More informationSD-1250 and SD-1600 Series Smoke Dampers
SD-1250 and SD-1600 Series Smoke Dampers Product Bulletin Code No. LIT-1201592 Issued January 30, 2014 Supersedes October 14, 2013 Johnson Controls provides a leakage-rated damper for life safety smoke
More informationModel FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.
Application Model FD-50 is a static rated fire damper approved for use in walls and partitions with fire resistance ratings of hours or more. This model carries a hour UL fire damper label. UL555 classifies
More informationModel VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options
Application and Design The series is a general purpose, low leakage control damper intended for application in low pressure and velocity systems. atings Pressure: 2 in. wg (.5 kpa) - pressure differential.
More informationFSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 FSD36, FSD36LP COMINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2 APPLICATION Ruskin FSD36 Series
More informationBaked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)
Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure
More information6. Butterfly Valves & Accessories
1. Plastic Pipes 2. Steel Pipes 3. Penetration Tubes 4. Piping Accessories 5. Needle Valves 6. Butterfly Valves & Accessories 7. Miscellaneous Valves 7 1. PLASTIC PIPES TYPES OF PLASTIC PIPES ADAPTATOR
More informationCURTAIN TYPE FIRE DAMPER
MODEL: IBD-2 / IBD-2H STANDARD CONSTRUCTION FIRE RATING UL 555 1-1/2 hours UL classification damper SS: 4 hours rating classification damper NOTES Damper s dimension is usually about 10 mm smaller than
More informationFSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FX (816) 765-8955 FSD60, FSD60LP COMINTION FIRE ND SMOKE DMPER 1 1 /2 HOUR UL555 RTED, UL555S LEKGE CLSS 1 PPLICTION Ruskin FSD60 Series ultra
More informationCCS Zone/Bypass Damper Assembly
Code No. LIT-1900539 Issued July 15, 2011 UZR-xx-x, UBR-xx-x, UZD-0xxX0xx-x, UBD-0xxX0xx-x CCS Zone/Bypass Damper Assembly Description The Commercial Comfort System (CCS) Zone/Bypass Damper are zone control
More informationThe EDGE. Self-Sealing Round Duct System. Northeastern Sheet Metal, Inc. 31 Depot Street Goffstown, NH 03045
The EDGE TM elf-ealing Round Duct ystem Northeastern heet Metal, Inc. 31 Depot treet Goffstown, NH 03045 P: 603.497.4166 F: 603.497.8518 www.nesmcorp.com The EDGE TM Features, Benefits & Construction 2
More informationVCD-23 Low Leakage CONTROL DAMPER
Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric actuators are available.
More informationModel VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options
Application The series is a general purpose control damper for applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. A wide range of electric
More informationSECTION ELECTRONIC ACTUATED PRESSURE REDUCING VALVES AND ACCESSORIES
SECTION 33 12 16.05 REDUCING VALVES AND ACCESSORIES PART 1 - GENERAL 1.1 THE REQUIREMENT A. The Electronic Actuated Pressure Reducing Valve (PRV) shall maintain a constant downstream pressure regardless
More informationEXTRACTION CHECK VALVES TYPE C09.6
Application Extraction check valves are valves used to to prevent the back flow of the service fluid in extraction and bleed lines of steam turbines. Each extraction check valve is designed exactly for
More informationHEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES
HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L HD SERIES MANUFACTURERS OF AIR/FIRE/SMOKE CONTROL PRODUCTS Product Description and Features Introduction The HD Series Multi-Leaf Volume
More informationWelded Valve Configurations
Welded Configurations Welded valve configurations are designed to improve the process in aseptic production facilities by reducing the dead legs in accordance to cgmp. Welded valve configurations may be
More informationTable of Contents. Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 4 Page 4 Page 5 Page 5 Page 5
-02 - Location and Mounting: AirflowMonitoringStation Table of Contents #1 - Right Angle wo/turning Vanes Mounting #2 - Right Angle w/turning Vanes Mounting #3 - Right Angle w/rounded Elbow Mounting #4
More informationSquare/Rect. and Square Louvered Face and Plaque Face Diffuser
/Rect. and Louvered Face and Plaque Face Diffuser Series J: Easily Adjustable from Horizontal to Vertical Vertical Discharge Application: Carnes steel (SK) and aluminum (SE) louvered face diffusers are
More informationFLOAT CONTROL VALVES
PROJECT NAME LOCATION FLOAT CONTROL VALVES INTRODUCTION This specification covers the design, manufacture, and testing of 8 in. (200 mm) through 36 in. (900 mm) Control Valves PART 1 - GENERAL 1. Standard
More informationFSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FX (816) 765-8955 FSD36, FSD36LP COMINTION FIRE ND SMOKE DMPER 1 1 /2 HOUR UL555 RTED, UL555S LEKGE CLSS 2 PPLICTION Ruskin FSD36 Series low leakage
More informationAMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers
AMCA MEMBER American Warming and Ventilating A Mestek Company Quality Air Control Dampers Over a century of dedication to quality products and customer satisfaction has enabled American Warming and Ventilating
More informationTHE WORLD S FASTEST DUCTING
NORDFAB DUCTING CATALOGUE Quick-Fit C l i p p e d D u c t i n g THE WORLD S FASTEST DUCTING & FLANGED DUCTWORK Nordfab QF Clipped and FL Flanged ducting QF clipped and FL flanged ducting offers a complete
More informationModel SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation
Application and Design The is a severe environment 316SS ultra low leakage control damper with rugged stainless steel airfoil blades designed to meet the highest standards established for commercial control
More informationCONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7
CONTROL DAMPERS MODEL 1380 HIGH PERFORMANCE ACKDRAFT DAMPER EXTRUDED ALUMINUM HEAVY DUTY Model 1380 is a high performance extruded aluminum gravity operated backdraft damper for use in medium to heavy
More information2520- EC Motor Speed Controller
2520- EC Motor Speed Controller T1 AC Line Voltage From Contactor T2 or Neutral 760-ECM ECM Motor BLACK ORANGE BLACK RED (+) Signal 24VAC (-) GND Features Motor Types: ECM (dc brushless) Motors Motor Speed:
More information