L O U V E R S & D A M P E R S

Size: px
Start display at page:

Download "L O U V E R S & D A M P E R S"

Transcription

1 L O U V E R S & D A M P E R S CALGARY EDMONTON LETHBRIDGE th Ave. SE St. NW St. N (403) (780) (403) sales@alggin.com edmsales@alggin.com sales@alggin.com

2 Page 1 EXTRUDED ALUMINUM STATIONARY LOUVERS LOUVRE " x 12" - 2" deep aluminum louver $55.85 LOUVRE " x 14" - 2" deep aluminum louver $90.00 LOUVRE " x 16" - 2" deep aluminum louver $90.00 LOUVRE " x 18" - 2" deep aluminum louver $ LOUVRE " x 20" - 2" deep aluminum louver $ LOUVRE " x 24" - 2" deep aluminum louver $ * louvers stocked in standard mill finish ALUMINUM BACK DRAFT DAMPERS DAMPERBDDDM12 12" x 12" aluminum BDD - duct mount $76.00 DAMPERBDDDM14 14" x 14" aluminum BDD - duct mount $ DAMPERBDDDM16 16" x 16" aluminum BDD - duct mount $ DAMPERBDDDM18 18" x 18" aluminum BDD - duct mount $ DAMPERBDDDM20 20" x 20" aluminum BDD - duct mount $ DAMPERBDDDM24 24" x 24" aluminum BDD - duct mount $ DAMPERBDDFFM12 12" x 12" aluminum BDD - flange mount $76.00 DAMPERBDDFFM14 14" x 14" aluminum BDD - flange mount $ DAMPERBDDFFM16 16" x 16" aluminum BDD - flange mount $ DAMPERBDDFFM18 18" x 18" aluminum BDD - flange mount $ DAMPERBDDFFM20 20" x 20" aluminum BDD - flange mount $ DAMPERBDDFFM24 24" x 24" aluminum BDD - flange mount $ LOW LEAKAGE STEEL CONTROL DAMPERS DAMPER " x 12" parallel blade control damper $96.50 DAMPER " x 14" parallel blade control damper $ DAMPER " x 16" parallel blade control damper $ DAMPER " x 18" parallel blade control damper $ DAMPER " x 20" parallel blade control damper $ DAMPER " x 24" parallel blade control damper $ See our complete line of Honeywell actuators on page 2 of the Miscellaneous section

3 Page 2 Model Inch Extruded Aluminum Stationary EXHAUST Louver 2 inches (50mm) Specify 2210 for channel frame Specify 2215 for flange frame Frame Thickness: 0.063" 6063-T5 extruded alum. Blade Thickness: 0.063" 6063-T5 extruded alum. Blade Centers: 2 inches (50mm) 30 degrees Minimum Height: 6 inches (152 mm) Max Panel Width: Max Panel Height: Standard Birdscreen: 1/2" x 1/2" Galvanized Model Inch Extruded Aluminum Stationary Stormproof INTAKE Louver 2 inches (50mm) Specify 2220 for channel frame Specify 2225 for flange frame Frame Thickness: 0.063" 6063-T5 extruded alum. Blade Thickness: 0.063" 6063-T5 extruded alum. Blade Centers: 3 inches (76mm) 45 degrees Minimum Height: 6 inches (152 mm) Max Panel Width: Max Panel Height: Standard Birdscreen: 1/2" x 1/2" Galvanized AVAILABLE ACCESSORIES Bird Screen: 1/4 x 1/4 inter crimped aluminum 1/2 x 1/2 inter crimped aluminum Insect Screen: 18 x 14 Mesh Finish: Finish (standard) Baked enamel Anodized Finish: Clear, Light Bronze, Medium Bronze & Dark Bronze Aluminum blank off panel 1" or 2" insulated blank off panel Hinged frame All welded construction Hinged frame and access door Security bars Extended sills Extended sleeves Filter racks Custom geometric shapes *** Contact your Alggin representative for pricing and availability ***

4 Page 3 Model Inch Extruded Aluminum Stationary EXHAUST Louver 4 inches (100mm) Frame Thickness: Blade Thickness: Blade Centers: Specify 2410 for channel frame Specify 2415 for flange frame 0.081" 6063-T5 extruded alum " 6063-T5 extruded alum. 3.5 inches (89mm) 35 degrees Minimum Height: Max Panel Width: Max Panel Height: Standard Birdscreen: 12 inches (305 mm) 144 inches (3650 mm) 1/2" x 1/2" Galvanized Model Inch Extruded Aluminum Stationary Stormproof INTAKE Louver 4 inches (100mm) Specify 2420 for channel frame Specify 2425 for flange frame Frame Thickness: 0.081" 6063-T5 extruded alum. Blade Thickness: 0.081" 6063-T5 extruded alum. Blade Centers: 4 7/8 inches (124mm) Minimum Height: Max Panel Width: Max Panel Height: Standard Birdscreen: 45 degrees 12 inches (305 mm) 144 inches (3650 mm) 1/2" x 1/2" Galvanized AVAILABLE ACCESSORIES Aluminum blank off panel Bird Screen: 1/4 x 1/4 inter crimped aluminum 1" or 2" insulated blank off panel 1/2 x 1/2 inter crimped aluminum Hinged frame Insect Screen: 18 X 14 Mesh All welded construction Finish: finish (standard) Hinged frame and access door Baked enamel Security bars Anodized Finish: Clear, Light Bronze, & Dark Bronze Extended sills Extended sleeves Filter racks Custom geometric shapes *** Contact your Alggin representative for pricing and availability ***

5 Page 4 Model 4000 Steel Control Damper : Depth Blades Open: Frame Thickness: Blade Thickness: Bearings: Axles: Min. Height: Max. Panel Width: Max. Panel Height: Max. System Pressure: Linkage: Motor Installation: 5 inches (127 mm) 6 3/8 inches (162 mm) 16 Ga galv. steel 16 Ga galv. steel Molded synthetic 3/8" plated bar Duct mounted frame 8 inches (203 mm) single blade 14 inches (356 mm) mult. blade 48 inches (1219 mm) 4" w.g. Concealed in frame galvanized Side shaft direct drive (extendable up to 12") Available in both "PB" parallel blade & "OB" opposed blade configurations. AVAILABLE ACCESSORIES: Belimo & Honeywell motors available (call for details) Jack shafts End switch for signaling peripheral devices Hand quadrants Chain operation for manual operation (spring closed) * Note: Dampers will be manufactured 1/4" smaller than given opening dimensions, unless otherwise specified. Model BDD Aluminum Back Draft Damper : Depth Blades Closed: Depth Blades Open: Frame Thickness: Blade Thickness: Blade Centers: Min. Height: Max. Panel Width: Std. Operation Method: Gravity Standard Seals: 2 3/4" (70 mm) 5 5/8" (143 mm) "DM" - duct mount frame "FM" - flange frame "FFM" - front flange frame 0.062" 6063-T5 extruded alum " 6063-T5 extruded alum. 3 3/4 inches (95 mm) 9 inches (229 mm) 60 inches (1524 mm) Vinyl blade seal AVAILABLE ACCESSORIES: 1/2 x 1/2 Bird Screen 18 x 14 Mesh Insect Screen Counter balancing without springs Manual locking device to keep blades open Manual operation c/w 6 ft. of chain * Note: "DM" & "FFM" dampers will be manufactured 1/4" smaller than given opening dimensions, unless otherwise specified. "FM" dampers will be manufactured to the exact size. *** Contact your Alggin representative for pricing and availability ***

6 L O U V E R S & D A M P E R S

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Positive Seal Damper Blades with Vinyl Gaskets 2.5 SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS BACKDRAFT DAMPERS BLADE OPTION: SR: 0.016-0.020 roll formed aluminum with vinyl gasket - used with fan motors under 1 HP SE: 0.05 extruded aluminum with vinyl gasket - used with fan motors over 1 HP Positive

More information

When Time is Everything... We Manufacture in Days - Not Weeks!

When Time is Everything... We Manufacture in Days - Not Weeks! When Time is Everything... We Manufacture in Days - Not Weeks! DAMPERS ACCESS DOORS LOUVERS July 2014 Specializing In Products For The HVAC Industry 763-783-7173 fax: 763-785-6977 1-800-297-9360 Customer:

More information

ARROW INDUSTRIAL PRODUCTS

ARROW INDUSTRIAL PRODUCTS IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products

More information

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

SafidDampers SPK Description. Standard Construction SPK ( Flange Type ) ( Flange Type ) SPK 30-300 Description SPK 30 - Series The single and multi-leaf s with extruded aluminum airfoil blades are designed for quite, efficient and reliable air volume control in air conditioning

More information

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options. Model Application The is a low leakage high performance control damper with extruded aluminum airfoil blades. Blades are completely contained within the frame allowing the damper to be directly mounted

More information

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-43 Extruded Airfoil Blade Control Damper Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure

More information

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type ) ( Flange Type ) SPK 30-100 Standard Construction FRAME: 160mm x 30mm x 1.5mm (16 Ga.) galvanized steel formed channel for flange connection. BLADES: 250mm max. width, 1.5mm (16 Ga.) galvanized steel. FINISH:

More information

VCD-23. Flange Options. Size Limitations

VCD-23. Flange Options. Size Limitations Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators

More information

Motorized Fire Dampers

Motorized Fire Dampers Model : OMFD-611 (Fusible link and spring return actuator) GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Static and

More information

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers Control s Model FDCB (Opposed Blade) FDHB (Parallel Blade) Aluminum Low Leakage Control s Frame:.081 extruded aluminum Blades:.125 extruded aluminum Bearings: bronze oilite Linkage: *concealed in frame

More information

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations. Application and Design The is a vertical style face and bypass low leakage damper. This model is intended for application in medium to high pressure and velocity systems. Smooth profile extruded aluminum

More information

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178) Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure

More information

VCD-23. Low Leakage CONTROL DAMPER

VCD-23. Low Leakage CONTROL DAMPER Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators

More information

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure: Application and Design is a low leakage damper with vertical blade orientation designed to meet the highest standards established for commercial control dampers. The is intended for application in medium

More information

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options Application The series is a general purpose control damper for applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. A wide range of electric

More information

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories. Insulated Control Dampers 2 Volume 1 - March 2010 6 Non-Insulated Control Dampers 8 Framing Accessories 9 Jack Shaft Steel Control Dampers Fire Dampers 10 11 Control Dampers and Fire Dampers 3900 Insulated

More information

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS Airodyne multi leaf volume control tampers have been specifically designed for use in air conditioning and ventilation system for volume,

More information

ARROW UNITED INDUSTRIES

ARROW UNITED INDUSTRIES IP-3R ARROW UNITED INDUSTRIES Building Tomorrow s Ventilation Today Heavy Duty Dampers Industrial, Power Plant & Commercial Applications ARROW UNITED INDUSTRIES has specialized in the design and manufacturing

More information

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING PUB. NO. 732-3 DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING The most widely used dampers in commercial HVAC applications Control Dampers - Extruded Aluminum

More information

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options Application and Design The series is a general purpose, low leakage control damper intended for application in low pressure and velocity systems. atings Pressure: 2 in. wg (.5 kpa) - pressure differential.

More information

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options. Application and Design The series is a vertical blade general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium

More information

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7 CONTROL DAMPERS MODEL 1380 HIGH PERFORMANCE ACKDRAFT DAMPER EXTRUDED ALUMINUM HEAVY DUTY Model 1380 is a high performance extruded aluminum gravity operated backdraft damper for use in medium to heavy

More information

VCD-23 Low Leakage CONTROL DAMPER

VCD-23 Low Leakage CONTROL DAMPER Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric actuators are available.

More information

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options. Application and Design The Series is a ruggedly built low leakage control damper with thermally insulated blades. The is intended for application in medium pressure and velocity systems. This model also

More information

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

CONTROL DAMPERS. Models 1810 & Model Model Model 1370 CONTROL DAMPERS CONTROL DAMPERS MODELS 1810 & 1820 MANUAL ALANCING DAMPERS STEEL Models 1810 and 1820 have been engineering and designed for manual balancing applications in low to medium pressure and

More information

Air Louvers OFAL 300 SERIES

Air Louvers OFAL 300 SERIES Fresh / Exhaust Model : OFAL GI 359 Description: Stationary Louvers is designed to provide air intake and air exhaust openings in building exterior walls to protect against the direct ingress of rain.

More information

Model VCD-20 3V CONTROL DAMPER

Model VCD-20 3V CONTROL DAMPER R Application and Design The series is a ruggedly built general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium

More information

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers AMCA MEMBER American Warming and Ventilating A Mestek Company Quality Air Control Dampers Over a century of dedication to quality products and customer satisfaction has enabled American Warming and Ventilating

More information

ID-141x 12-Gauge Hat Channel Industrial Damper

ID-141x 12-Gauge Hat Channel Industrial Damper ID-141x 12-Gauge Hat Channel Industrial Damper Product Bulletin Code No. LIT-12011355 Issued June 12, 2013 Supersedes March 13, 2012 Since 1905, Johnson Controls has developed and refined air control products

More information

INDEX. Chapter1 6. air master. Volume Control Dampers

INDEX. Chapter1 6. air master. Volume Control Dampers Chapter1 6 INDEX 1 Volume control damper...:avcd...16.1 Standard sizes...16.2 Fixing details...16.2 How to order...16.2 Performance chart...16.3 2. Circular volume control damper....:avcd-c....16.4 Standard

More information

Hoods and Gravity Ventilators Models USEV, USIV, USLEV, and USLIV

Hoods and Gravity Ventilators Models USEV, USIV, USLEV, and USLIV Hoods and Gravity Ventilators Models USEV, USIV, USLEV, and USLIV Construction Features USEV/USIV Hood and base constructed of heavy gauge aluminum Rigid structural aluminum braced for extra strength Birdscreen

More information

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options Application and Design Thermal Dispersion Air Measuring Station with VCD-42 Control Damper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage

More information

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42V Air Measuring Station with VCD-42V Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) 14 ga. (2mm) Frame Type 5 in. x 1 in. hat channel - Blade

More information

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper Application and Design W x H Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness External Minimum Size 16 ga. (1.5mm) Internal Single Section Maximum Size Multiple

More information

BD-1600 Balancing/Zone Control Damper

BD-1600 Balancing/Zone Control Damper BD-1600 Balancing/Zone Control Damper Product Bulletin Code No. LIT-12012355 Issued September 2016 Refer to the QuickLIT website for the most up-to-date version of this document. The BD-1600 Balancing/Zone

More information

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper. Application The WD200 series are electrically motorized backdraft dampers that open when energized and spring return close when deenergized. The WD200 series are for horizontal or vertical mounting. Primary

More information

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED BC 09 Pressure Relief Dampers PRD-GAB-12B Table Of Contents S. No Description Page No 1 General Information 1 2 PRD/NRD- B10 Series 2 3 CBD - B20 Series 3 4 BDD - B30 Series 4 5 Engineering and Performance

More information

M I S C E L L A N E O U S

M I S C E L L A N E O U S M I S C E L L A N E O U S www.alggin.com CALGARY EDMONTON LETHBRIDGE 4540-46th Ave. SE 12110-154 St. NW 1126-36 St. N (403) 252-0132 (780) 424-0132 (403) 320-8732 sales@alggin.com edmsales@alggin.com sales@alggin.com

More information

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty Submittal Data Model PELV-100 Penthouse Elevator Vented Hood Application and Design The PELV-100 Penthouse Elevator Vented Hood is a gravity ventilator penthouse with an 18" x 18" gasketed access door

More information

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations Application and Design The series is an ultra low leakage damper with rugged steel airfoil blades designed to meet the highest standards established for commercial control dampers. The airfoil shape reduces

More information

MOTORIZED VOLUME DAMPER

MOTORIZED VOLUME DAMPER MOTORIZED VOLUME DAMPER 1 a perfect partner in performance... Our Product Ranges Dampers 1 Fire Dampers 2 Fire / Smoke Dampers 3 Volume Control Dampers 4 Motorized Control Dampers 5 Pressure Relief Dampers

More information

AIR CONDITIONING PRODUCTS COMPANY

AIR CONDITIONING PRODUCTS COMPANY Quality Products for Motorized Dampers AIR CONDITIONING PRODUCTS COMPANY Wall Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga ble Shutter Drainable Louver Supply Damper Fiberglass

More information

A Complete Line of Quality Products for Marine Applications

A Complete Line of Quality Products for Marine Applications american warming and ventilating A Mestek Company A Complete Line of Quality Products for Marine Applications 1 About AWV Marine Dampers At American Warming and Ventilating, we are committed to design

More information

SECTION DUCTWORK ACCESSORIES

SECTION DUCTWORK ACCESSORIES SECTION 15910 DUCTWORK ACCESSORIES PART 1- GENERAL SCOPE This sections includes accessories used in the installation of duct systems. Included are the following topics: PART 1- GENERAL Related Work Reference

More information

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations. Application and Design The WD300 series dampers are designed to prevent reverse airflow in horizontal exhaust applications. The WD300 features a pressure sensitive blade design that opens and remains open

More information

HVAC Control & Balancing Dampers

HVAC Control & Balancing Dampers HVAC Control & Balancing Dampers Models VCD, MBD and RBD Selection Construction Performance H* W* 1June 2017 Design and Construction Features Bearing Shaft Extension Jamb Seal Commercial Control Dampers

More information

HVAC Control & Balancing Dampers

HVAC Control & Balancing Dampers HVAC Control & Balancing Dampers Models VCD, MBD and RBD Selection Construction Performance H* W* August 1 2013 HVAC Control and Balancing Dampers Commercial Control Dampers are used in buildings to regulate

More information

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation Application and Design The is a severe environment 316SS ultra low leakage control damper with rugged stainless steel airfoil blades designed to meet the highest standards established for commercial control

More information

STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS

STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS 14 15 STATIONARY LOUVER STATIONARY LOUVER SSL - 100 SSL SERIES SSL SERIES [SSL - 100, SSL - 110, SSL - 120] Air Performance Pressure Drop SSL - 100 Stationary Louver is a weather louver

More information

PC-125x Counter-Balanced Backdraft Damper

PC-125x Counter-Balanced Backdraft Damper PC-15x Counter-Balanced Backdraft Damper Product Bulletin Code No. LIT-101180 Issued April 7, 015 Refer to the QuickLIT Web site for the most up-to-date version of this document. Since 1885, Johnson Controls

More information

HCD-230 Industrial Control Damper

HCD-230 Industrial Control Damper Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-33 Air Measuring Station with VCD-33 Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized

More information

Series HCD Airfoil Control Damper

Series HCD Airfoil Control Damper Series HCD Airfoil Control Damper Model: HCD-1 The Holyoake HCD-1 is a precisely made volume and pressure control device with extremely low leakage when closed, (in the range of 0.003m 3 /s at 100 Pa).

More information

VOLUME CONTROL DAMPERS

VOLUME CONTROL DAMPERS VOLUME CONTROL DAMPERS CONSTRUCTION FEATURES FRAME Roll formed 16 gauge galvanized steel channel with welded corners. X-Standard, Z-optional AXLES Roll formed 18 gauge galvanized steel. 1/2" Round chrome

More information

CUSTOMISED PRODUCTS COMPETITIVE PRICING ON-TIME DELIVERY PRODUCT GUIDE.

CUSTOMISED PRODUCTS COMPETITIVE PRICING ON-TIME DELIVERY PRODUCT GUIDE. CUSTOMISED PRODUCTS COMPETITIVE PRICING ON-TIME DELIVERY PRODUCT GUIDE ABOUT US Dragon Grilles has over 50 years experience in the manufacture and supply of air handling products. Our production facility

More information

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type 1 SUBMITTAL DATA Series 1000 Air-Foil Control Damper SP Standard Profile 2" 50.8 mm In Duct or Flanged to Duct Install Types 4" 101.6 mm 6.4" 162.6 mm blades fully open 1" 25.4 mm Extended Rear Flange

More information

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes:

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes: SECTION 15970 HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Thermostats, temperature transmitters, controllers, automatic valves, dampers, damper operators, pneumatic/ electric

More information

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

HVAC Control Damper Models VCD and MBD. Selection Construction Performance HVAC Control Damper Models VCD and MBD Selection Construction Performance November 2006 HVAC Control and Manual Balancing Dampers Greenheck HVAC control dampers bring the same quality engineering and manufacturing

More information

FSD60/MFSD60 Multi-blade Fire Damper

FSD60/MFSD60 Multi-blade Fire Damper DAMPER FSD60/MFSD60 Multi-blade Fire Damper Tested and conform to Tested and conform to BS476:Part20:1987 The ASLI Multi-Blade Fire Dampers have been developed to provide the versatility required for today

More information

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I Application and Design Model is a combination fire smoke damper that is UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model s operational ratings

More information

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options Application Thermal Dispersion Air Measuring Station with VCD-23 Control Damper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage control

More information

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating Application Model is a multi-blade fire damper with 3V style blades. The has been qualified to 4000 fpm (20.3 m/s) and 10 in. wg (2.5 kpa) for dynamic closure in emergency fire situations. Model may be

More information

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited April 11 EnergyShield ES EnergyShield ES Air Control and Shut off Dampers Features Dampers suitable for systems requiring air control and low closed blade leakage characteristics. Low torque characteristics.

More information

Cable Connection (at damper) Damper in Opened Position. (Side View) Model FQAA opposed blades BCW. Model BO-300, BO-896, BO-896-P

Cable Connection (at damper) Damper in Opened Position. (Side View) Model FQAA opposed blades BCW. Model BO-300, BO-896, BO-896-P Cable Operated s - Bowden Cable System Model FQAA The Model FQAA was developed for air balancing at the mid/duct above inaccessible ceilings with Mechanical Push-Pull adjustments at a terminal controller.

More information

XeteX, Inc. All Rights Reserved.

XeteX, Inc. All Rights Reserved. Model XC Indoor or outdoor mounted, simple, in-case aluminum flat plate exchanger with options for frost control. Ideal for inline installations: in duct-work systems, in built-up units, or in modular

More information

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper Volume Control Dampers Incorporating Series HVC-VCD Excellent general purpose volume control damper Lightweight aluminium construction Fully protected linkage system positioned outside of airstream Very

More information

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options Application and Design The combines the functionality of an accurate airflow measuring station and a low leakage control damper into one compact assembly that both measures and regulates airflow volumes

More information

SMOKE DAMPER - CLASS F MODEL BMSD

SMOKE DAMPER - CLASS F MODEL BMSD UL CLASSIFIED DAMPERS SMOKE DAMPER - BMSD SERIES STANDARD CONSTRUCTION Standards: Designed and tested in accordance with UL555S. Meets NFPA 90A and SMACNA requirements for fire & smoke dampers. Application:

More information

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in. R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and

More information

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction. Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

SPECIALTY PRODUCT CATALOGUE. Manufacturers of quality residential, commercial, industrial, and institutional HVAC duct & fittings.

SPECIALTY PRODUCT CATALOGUE. Manufacturers of quality residential, commercial, industrial, and institutional HVAC duct & fittings. SPECIALTY PRODUCT CATALOGUE 3728 Overlook Road (919) 954-9950 Fax: (919) 954-9951 45 DEGREE TAKEOFF WITH GASKET FLANGE AND CHOICE OF MANUAL DAMPER AND/OR 2 STANDOFF QUADRANT DIAMETER RECT. OPENING 4 8

More information

SECTION CONTROL DAMPERS

SECTION CONTROL DAMPERS SECTION 23 09 13.43 - CONTROL DAMPERS PART I - GENERAL 1.1 SECTION INCLUDES A. Airfoil Dampers, Heavy Duty Galvanized Steel B. Thermally Insulated Dampers, Heavy Duty Galvanized Steel C. Airfoil Dampers,

More information

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers Model : OSTL GI 341 Description: OPTIMA make Sand Trap Louver is used as pre-filter for the protection of air conditioning plants in area exposed to extreme levels of industrial pollution. It has a high

More information

CEILING AIR INLETS CORROSION PROOF ECONOMICAL DURABLE. Ideal for all Agricultural applications.

CEILING AIR INLETS CORROSION PROOF ECONOMICAL DURABLE. Ideal for all Agricultural applications. CEILING AIR INLETS CORROSION PROOF ECONOMICAL DURABLE Ideal for all Agricultural applications. These durable ceiling inlets are rotational moulded with high impact polyethylene. They are designed to offer

More information

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model FSD-212. Combination FIRE SMOKE DAMPERS R APPLICATION Model is a combination fire smoke damper with 3V style blades. The has been qualified to 2000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operation and dynamic closure in emergency fire smoke

More information

CFSD Series. Product Description

CFSD Series. Product Description COMBINATION FIRE AND SMOKE DAMPER 1-1/2 HR LEAKAGE RESISTANCE CLASS II 250 O F FILE NO: R22165 Product Description Combination Fire / Smoke dampers provide an automatic means of localizing areas of smoke

More information

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS 96 97 SD SERIES SD for Use in Dynamic Systems Types Galvanized Steel Construction as Standard.. Sleeve Type, Model: SD - 0-00. Circular Type, Model: SD - 50-00. Oval Type, Model: SD - 60-00

More information

Zero Leakage Isolation Damper

Zero Leakage Isolation Damper SPECIFICATION The damper casing is formed from 3.0 mm thick sheet steel into a rigid channel section to ensure proper alignment of blades and shafts. Where circular dampers are required, additional spigot

More information

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR) UL CLASSIFIED DAMPERS COMBINED FIRE/SMOKE DAMPER - BMFSD SERIES STANDARD CONSTRUCTION Standards: Designed and tested in accordance with UL555 & UL555S. Meets NFPA 90A and SMACNA requirements for fire &

More information

WE GUIDE AIR LOUVERS

WE GUIDE AIR LOUVERS WE GUIDE AIR LOUVERS index >> SAND TRAP LOUVERS - STL / STLC 01-02 >> 2 INCH EXHAUST AIR LOUVERS - EAL - 2 03 >> 4 INCH EXHAUST AIR LOUVERS - EAL - 4 04 >> GRAVITY AIR LOUVERS - GAL 05 >> FRESH AIR LOUVERS

More information

GRAVITY VENTILATORS SIZING

GRAVITY VENTILATORS SIZING GRAVITY VENTILATORS SIZING BGH RLX Sizing The tables shown offer quick selections at common static pressure points. Selection choices vary widely due to field conditions and size choices. The following

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES 49-240 48LL1 49-280 49-480 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance. Linear bar grilles offer a choice

More information

Dampers. Louvers. Caring for Human Life & Property (FIRE, SMOKE & HVAC) NAFFCOFlow.com

Dampers. Louvers. Caring for Human Life & Property (FIRE, SMOKE & HVAC) NAFFCOFlow.com Dampers (FIRE, SMOKE & HVAC) Louvers & Caring for Human Life & Property Contents i 01 02 04 07 09 11 12 15 16 16 18 19 24 26 INTRODUCTION FIRE & SMOKE DAMPERS Curtain Fire Damper Motorized Fire Damper

More information

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES OSU PROJECT NO. 30-04-15 PAGE 1 PART 1 GENERAL 1.1 WORK INCLUDED A. Medium and low pressure duct accessories, sealants and tapes, flexible connectors, fire dampers, smoke dampers, combination smoke and

More information

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and

More information

DAMPERS WE CONTROL AIR

DAMPERS WE CONTROL AIR WE CONTROL AIR Ver. 1 January 2017 index >> VOLUME CONTROL DAMPER - 3VCD SERIES >> VOLUME CONTROL DAMPER - AVCD SERIES >> LOW-LEAKAGE VOLUME CONTROL DAMPER - LVCD SERIES >> ROUND VOLUME CONTROL DAMPER

More information

INSULATED CANTED ROOF CURB NON-PROPELLER PRODUCTS

INSULATED CANTED ROOF CURB NON-PROPELLER PRODUCTS INSULATED ANTED ROOF URB NON-PROPELLER PRODUTS Wood Nailer A 3" 3/4" 3" 1" Semi-Rigid Insulation Damper Shelf (Optional) (1) B OPTIONS: 1. Damper Shelf. 2. Metal Liner - solid or screen type. 3. Burglar

More information

INSULATED CANTED ROOF CURB NON-PROPELLER PRODUCTS

INSULATED CANTED ROOF CURB NON-PROPELLER PRODUCTS INSULATED ANTED ROOF URB NON-PROPELLER PRODUTS Wood Nailer A OPTIONS: 1. Damper Shelf. 2. Metal Liner - solid or screen type. 3. Burglar bars - 1/2" dia. on 6" centers. 4. Finishes - baked or air-dried

More information

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES SECTION - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this

More information

GRAVITY VENTILATORS SIZING

GRAVITY VENTILATORS SIZING GRAVITY VENTILATORS SIZING RCXII (sizes 6-20) RCXII (sizes 24-36) RCXII-SF BGH RLX Sizing The tables shown offer quick selections at common static pressure points. Selection choices vary widely due to

More information

CONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc.

CONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc. Nailor Industries Inc. CONTROL & ACKDRAFT DAMPERS 1 Contents Page No. Product Overview 4 Features of Nailor Control Dampers 1 Standard Performance Control Dampers Models 11/12 Low Leakage Vee-lades 11

More information

2018 STOCK CATALOG. Sales Offices. Serving Upstate New York, Vermont & Western Massachusetts with Quality HVAC Products for over 50 Years

2018 STOCK CATALOG. Sales Offices. Serving Upstate New York, Vermont & Western Massachusetts with Quality HVAC Products for over 50 Years Serving Upstate New York, Vermont & Western Massachusetts with Quality HVAC Products for over 50 Years 2018 STOCK CATALOG Sales Offices ALBANY, NEW YORK BUFFALO, NEW YORK ROCHESTER, NEW YORK SYRACUSE,

More information

SD-1250 and SD-1600 Series Smoke Dampers

SD-1250 and SD-1600 Series Smoke Dampers SD-1250 and SD-1600 Series Smoke Dampers Product Bulletin Code No. LIT-1201592 Issued January 30, 2014 Supersedes October 14, 2013 Johnson Controls provides a leakage-rated damper for life safety smoke

More information

makes sure products are delivered Products are offered in steel,

makes sure products are delivered Products are offered in steel, Residential Construction Features Residential Registers, Grilles & Diffusers No one satisfies the demands for For example: an electro-deposition air distribution solutions better than paint creates a flawless

More information

Model FSD-331 Combination Fire Smoke Dampers

Model FSD-331 Combination Fire Smoke Dampers R APPLICATION Model is a high performance combination fire smoke damper with class I leakage. High strength airfoil blades ensure the lowest resistance to airflow in HVAC systems with velocities to 4000

More information

AD-1250 Airflow Measuring Station

AD-1250 Airflow Measuring Station AD-1250 Airflow Measuring Station Product Bulletin Code No. LIT-12011472 Issued March 2016 Refer to the QuickLIT website for the most up-to-date version of this document. The AD-1250 Airflow Measuring

More information

GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS

GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS GRAVITY INTAKE and EXHAUST ROOF VENTILATORS SECTION 21 GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS Series GE and GI Low Silhouette This attractive low silhouette design is available in specific versions

More information

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating R APPLICATION Model FSD-211 is a combination fire smoke damper with 3V style blades. The FSD-211 has been qualified to 2000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operation and dynamic closure in emergency

More information

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating. Application Model is a combination fire smoke damper with 3V style blades. This model is designed for operation and dynamic closure in emergency fire smoke situations. It is rated for airflow and leakage

More information

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178) R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken blade to eliminate the transfer of heat or cold penetration and reduced

More information