Hydro-Brake Optimum Design Tool. Step by Step Guide
|
|
- Antony Patrick
- 6 years ago
- Views:
Transcription
1 Hydro-Brake Optimum Design Tool Step by Step Guide
2 Flow Control Design in Just 3 Simple Steps Step 1: Enter Design Inputs Step 2: Review Design Onscreen Step 3: Download Detailed Design Outputs Direct to your Computer
3 Before Using the Tool View the Hydro-Brake Optimum Video at
4 Registration / Login On first use, you will be invited to Register and will be able to use the tool straight away On subsequent visits, log in using the User Name and Password supplied during Registration
5 Step 1) Enter Design Inputs
6 Hydraulic Response Characteristic Curve The Hydraulic Response Characteristic Curve can be defined using 3 points: 1. Flush-Flo The point at which a vortex begins to build within the unit. 2. Kick-Flo The point at which a stable vortex is formed and maintained 3. Primary Design Point A point along the curve where the flow is controlled to a specified value at a known head.
7 Primary Design Point: Design Head Design head is taken as the difference in elevation between the invert of the outlet pipe and the top water level (TWL) upstream. Maximum Design TWL Design Head Maximum Design TWL Design Head Hydro-Brake Optimum
8 Primary Design Point: Design Flow The Design Flow should be set at the maximum permissible discharge rate from the catchment or subcatchment. This will generally be specified by the authority responsible for the downstream receiving waterbody or sewer.
9 Customised Hydraulic Response As shown right, the primary design point alone is not sufficient to design the Hydro- Brake Optimum as a number of different flow controls can all achieve the same primary design point. However, each unit will follow a different path to reach the primary design point and so can fulfil a different primary hydraulic objective.
10 Customised Hydraulic Response: Objective 1. Minimise Storage Requirements (Default) Maximises the flow rate at the Flush-Flo point and the head at the Kick-Flo point to pass forward as much flow as possible at all heads up to and including the design head without exceeding the design flow.
11 Customised Hydraulic Response: Objective 2. Minimise Blockage Risk Maximises the throughlet passages to minimise the risk of any debris carried within the flow from becoming lodged in the unit.
12 Customised Hydraulic Response: Objective 3. Future Proof Adds an adjustable inlet to the unit and sets this at close to it s mid-point to allow the greatest possible flexibility for dealing with future changes in the system requirements. Typically, the Design Flow can be increased or decreased by 10% post installation. Note: Modelling of the adjustment range is not currently supported. Contact us to obtain full details.
13 Customised Hydraulic Response: Flush-Flo Flush-Flo Note: Alternatively to selecting a standard Objective, you can define the flow rate at which the vortex begins to form (Flush-Flo ). This can be set at less than, equal to or greater than the Design Flow. Leaving the Flush-Flo input box empty will automatically set the Flush-Flo equal to the Design Flow
14 Site Options: Water Type Surface water only Foul Water Combined Surface and Foul Water
15 Site Options: Sump Available Sump available No Sump available Design Head Sump required No sump required The Sump Available tick box is used to indicate whether the user would allow standing water upstream of the flow control. This selection also tailors the design of the Hydro-Brake Optimum to be the most suitable configuration for the application.
16 Mechanical Build Options: Mounting Style Select your desired standard mounting style: Mounting Plate (Flat or Curved) Push-Fit Spigot Mounting Lugs (Default) Note: Some mounting styles may not be available for particular design inputs. Contact us for bespoke mounting solutions or off-site solutions.
17 Mechanical Build Options: Adjustable Inlet Units can be supplied with or without an adjustable inlet. Flow rates can typically be adjusted by 20% post installation. Note: Future Proof Objective requires an adjustable inlet
18 Step 2) Review Design Outputs: Hydraulic Characteristics
19 Review Design Outputs: Key Dimensions
20 Step 3) Obtain Design Files Your selected design files can be downloaded to your computer once you are happy with the design. Hydraulic Characteristic Curve Dimensioned Drawing Hydraulic Modelling Data To suit commercial hydraulic modelling software package selected, see table below for currently supported packages.
21 Hydraulic Modelling Data Micro Drainage Compatible (.csv) Data in 0.1m or 0.2m Head Increments (.csv) Generic Data (.csv) MircoDrainage 2016 MicroDrainage 2014 WinDes 2013 WinDes w12 WinDes w11 and earlier 110 lines of head / flow data in.csv format, suitable for viewing in Microsoft Excel (or similar).
22 Hydro-Brake Optimum Design Tool Download the User Guide for further information. Try the tool for yourself at
23 Thank you
ACO Water Management: Civils + Infrastructure
ACO Water Management: Civils + Infrastructure Uniclass JR12/JR23 L731 CI/SfB (52.7) ACO Q-Brake Vortex Vortex flow controls ACO Q-Brake Vortex Introduction to the ACO Group Throughout the world, the ACO
More informationMono Pumps PSS Eco 1-60
Mono Pumps PSS Eco 1-60 Page 1 of 12 Pump Unit Specification G60 Grifter (grinder pump) Specification Specification Topic Manufacturer Model Nominal flow rate Maximum Head capability Flow at Max. Head
More informationConfiguration Diagrams
Configuration Diagrams Off Grid AC Coupled By connecting and communicating with up to 5 x KACO 02 series inverters to the load side of the SP PRO system, it is possible to utilise efficient high voltage
More informationEPIC J3413. Uniclass L L2123. CI/SfB (52.5) In6. The most advanced drainage system of its kind. ACO Qmax. Technical Data
Uniclass L7315 + L2123 EPIC J3413 CI/SfB (52.5) In6 The most advanced drainage system of its kind ACO Qmax Technical Data ACO Qmax System Contents Load Classes 3 ACO Qmax 600 System Pedestrian and Car
More informationCSO/STORMWATER MANAGEMENT. Hydrovex VHV / SVHV Vertical Vortex Flow Regulator
CSO/STORMWATER MANAGEMENT Hydrovex VHV / SVHV Vertical Vortex Flow Regulator HYDROVEX VHV / SVHV VERTICAL VORTEX FLOW REGULATOR INTRODUCTION One of the major problems of urban wet weather flow management
More informationAutomatic Recirculation Valves One Step Centrifugal Pump Minimum Flow Protection
Automatic Recirculation s One Step Centrifugal Pump Minimum Flow Protection HPM Series ENGINEERINGInc. Portage Avenue, Three Rivers, MI USA Phone: -7- Fax: -78-7 Centrifugal Pumps Require Protection If
More informationCSO/STORMWATER MANAGEMENT. HYDROVEX FluidMid Flow Monitoring & Regulating Station with Siphon (Type G)
CSO/STORMWATER MANAGEMENT HYDROVEX FluidMid Flow Monitoring & Regulating Station with Siphon (Type G) HYDROVEX FLUIDMID FLOW MONITORING & REGULATING STATION WITH SIPHON (TYPE G) APPLICATION The HYDROVEX
More informationSECTION 9 STORM SEWER INLETS
SECTION 9 STORM SEWER INLETS CITY OF WESTMINSTER STORM DRAINAGE DESIGN AND TECHNICAL CRITERIA SECTION 9 STORM SEWER INLETS 9.1 INTRODUCTION There are three types of inlets: curb opening, grated, and combination
More information/ / Flygt 2700-series Corrosion resistant dewatering pumps
Flygt 2700-series Corrosion resistant dewatering pumps When the extreme is the ordinary Mines, power stations, paper industries, steel mills, and chemical industries. These are typical examples of environments
More informationThe Pump Matic Range
The Below Ground packaged pumping Stations Ideal for - Sewage, Wastewater, Stormwater Pump Technology Ltd, manufactures its own pumping station tanks. We have complete control over the construction, quality
More informationTon-Tel Multi-Deck Weighbridge
Weighbridge Rugged construction, Accurate weights Weightel digital load cells from 6 tonnes to 30 tonnes capacity OIML Approved Plug-And-Weigh Proven reliability Weightel digital load cells for maximum
More informationStormwater Treatment System
The Up-Flo Filter Stormwater Treatment System Table of Contents 3 Up-Flo Filter - Overview - General Product Description - Typical Configurations - Maintenance Services 4 Operation - Introduction - Pollutant
More informationJUNG PUMPEN COMPLI 100 MC SEWAGE LIFTING STATIONS
APPLICATION The sewage lifting stations compli 100, compli 500 and compli 1000 with MultiCut cutting system are uses especially for disposal in special objects, such as weekend cottages, houseboats, toilets
More informationFight F.O.G. with AMA-GREASE Separator System Solutions
Our technology. Your success. Pumps n Valves n Service Fight F.O.G. with AMA-GREASE Separator System Solutions 02 Introduction Customisable Two-Compartment Stainless Steel Sludge and Grease Separator System
More informationFOX TrimAway INSTALLATION AND OPERATING INSTRUCTIONS FAMILIARIZE YOURSELF WITH THE SYSTEM COMPONENTS
FOX TrimAway INSTALLATION AND OPERATING INSTRUCTIONS FAMILIARIZE YOURSELF WITH THE SYSTEM COMPONENTS Check your shipment against the packing list, the original quote and the following drawings. Contact
More informationJUNG PUMPEN MULTICUT SEWAGE PUMPS
APPLICATION Centrifugal submersible sewage pumps fitted with the MultiCut cutting system are used as stationary appliances for backpressure protection of detached houses. They are suitable for pumping
More informationBFF Motorised Trim Wheel - Set-up
BFF Motorised Trim Wheel - Set-up Table of Contents Summary of Set-up Steps...1 BFF Motorised Trim Wheel - Setup Details...2 Final Set-Up For Direct Connection To FSUIPC/XPUIPC...5 Final Set-Up For Direct
More informationHaynes Manual Volvo 940 Diesel
Haynes Manual Volvo 940 Diesel If you are looking for a book Haynes manual volvo 940 diesel in pdf format, then you've come to loyal site. We presented utter version of this ebook in PDF, doc, DjVu, txt,
More informationINSTRUCTION MANUAL. Stephenson Road Speedwell Industrial Estate Staveley Chesterfield S43 3JN
INSTRUCTION MANUAL Stephenson Road Speedwell Industrial Estate Staveley Chesterfield S43 3JN Telephone: 0800 1300 402 Fax: 01246 471 277 Website: www.morclean.com Email: information@morclean.com Contents
More informationJUNG PUMPEN compli 100 MC Sewage lifting stations
Application The sewage lifting stations compli 100, compli 500 and compli 1000 with MultiCut cutting system are uses especially for disposal in special objects, such as weekend cottages, houseboats, toilets
More information50 HZ. Ready DURABLE, LIGHTWEIGHT AND EASILY SERVICEABLE SUBERSIBLE SUBMERSIBLE PUMPS.
50 HZ Ready DURABLE, LIGHTWEIGHT AND EASILY SERVICEABLE SUBERSIBLE SUBMERSIBLE PUMPS. Multipurpose. Multiple use. Made for the duration. Whether it s for construction or industrial sites, manholes or emergency
More informationINSTALLATION, OPERATING AND SERVICE MANUAL
INSTALLATION, OPERATING AND SERVICE MANUAL ECONO-mist WATER SOFTENER Demand Regeneration 7-LMC56-75B 7-LM56-75B 7-LM56-100B 7-LM56-150B 7-LM56-200B Congratulations on purchasing your new Lancaster Water
More informationGlossary. 116
Sequential Fuel Injection Sequential means that each injector for each cylinder is triggered only one time during the engine s cycle. Typically the injector is triggered only during the intake stroke.
More informationFiltomat M100/MG Filters
Filtomat M100/MG Filters Hydraulic self-cleaning screen filters, with no external power source required flow rates M100: up to 400 m 3 /h (1,760 gpm) MG: up to 800 m 3 /h (3,520 gpm) minimum operating
More informationSOLUTIONS WORLD LEADING PASTE & THICKENED TAILINGS FLOW CONTROL. Every point of the delivery process, covered.
Image courtesy of Stripes Engineering - Gunnedah NSW PASTE & THICKENED TAILINGS FLOW CONTROL WORLD LEADING SOLUTIONS Every point of the delivery process, covered. valve solutions OFFER IMPROVED SAFETY
More informationSelect the right heating or cooling coil for your project! Instantly size and cost your chosen coil with the SPC2000 coil-selection program.
www.spcoils.co.uk SPC2000 Coil Selection Program User guide V2.1 Select the right heating or cooling coil for your project! Instantly size and cost your chosen coil with the SPC2000 coil-selection program.
More informationFilter Type PR-BW 100. Filtration
Filter Type PR-BW 100 Filtration 3 2 Debris Filter for Cooling Water and other Liquids The PR-BW 100 is an automatic Backwash Filter for the separation of macro fouling and other particles from liquids
More informationVersion: 1.0 Mat.-Nr.: DBUS-WB50-80US
WINDY BOY 3000-US / 5000-US / 6000-US / 7000-US / 8000-US Addendum operating requirements Version: 1.0 Mat.-Nr.: DBUS-WB50-80US 1 Notes on this addendum 1.1 Validity This addendum does not replace the
More informationHelp Manual. (DI2 Adapter for other E-BIKE system)
(English) HM-EO.3.2.1-00 Help Manual (DI2 Adapter for other E-BIKE system) Check the following support site for the latest support information. http://e-tubeproject.shimano.com CONTENTS For BOSCH E-BIKE
More informationOnline Monitoring Webserver V1.0
Online Monitoring Webserver V1.0 1 IMPRINT Original User Manual Online Monitoring Webserver V1.0 China Address: No.2 Tianhe Road, Trina PV Industrial Park, New District, Changzhou, Jiangsu Postcode: 213031
More information8LITRE HAND SPRAYER MODEL NO: PHS8B USER INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS
8LITRE HAND SPRAYER MODEL NO: PHS8B PART NO: 3402268 USER INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1216 INTRODUCTION Thank you for purchasing this CLARKE Sprayer, designed for use with insecticides or other
More informationInstallation, Operation & Maintenance Manual. TotlSep (TS) Series. FRP Oil/Water Separator
THE ART & SCIENCE OF WASTEWATER TREATMENT Installation, Operation & Maintenance Manual TotlSep (TS) Series FRP Oil/Water Separator Revised 09/2015 TABLE OF CONTENTS 1.0 PREFACE... 3 1.1 BACK CHARGE POLICY...
More informationFarm to Farm User Guide
Farm to Farm User Guide It is now a legal requirement that all pig movements be recorded electronically. To do electronic pig movement licences you will first need to log onto www.eaml2.org.uk You will
More informationCONTROL LAMBDA INSTALLATION MANUAL
CONTROL LAMBDA INSTALLATION MANUAL The CONTROL LAMBDA is tailored to be installed on vehicles where the GASOLINE NGV dual conversion has to be done caring for environment with its highest performance.
More informationPressure-compensating, Continuously Self-cleaning Dripper. Techline CV 16 mm
Sub- and On-surface dripperline with 0.14 bar Check Valve anti-drain (CV) system for efficient pulse irrigation, prevents water draining and eliminates need for refill. Check valve, anti drain mechanism
More informationPressure-compensating, Continuously Self-cleaning Dripper. Techline CV 17 mm
Sub- and On-surface dripperline with 0.14 bar Check Valve anti-drain (CV) system for efficient pulse irrigation, prevents water draining and eliminates need for refill. Check valve, anti drain mechanism
More informationPIM Pressure Independent Module
PIM Pressure Independent Module PIM : Product Overview BENEFITS AT A GLANCE QUIET VAV DIFFUSER OPERATION The PIM Pressure Independent Module is a modulating static pressure controller/actuator that allows
More informationAfghanistan Energy Study
Afghanistan Energy Study Universal Access to Electricity Prepared by: KTH-dESA Dubai, 11 July 2017 A research initiative supported by: 1 Outline Day 1. Energy planning and GIS 1. Energy access for all:
More informationFreefall metal detection system Vistus with separator ST 2.0
Freefall metal detection system Vistus with separator ST 2.0 Reliable metal detection ensuring optimum product quality Separator ST 2.0 benefits Dust-proof design for minimal product loss and increased
More information1995 Dodge Ram 2500 Service Manual
1995 Dodge Ram 2500 Service Manual If you are searched for the ebook 1995 dodge ram 2500 service manual in pdf form, then you've come to faithful website. We presented full variation of this ebook in epub,
More informationUser manual Suppliers evaluation process
User manual Suppliers evaluation process Document status Version Date Main changes Approved to 6 03/10/2014 Add paragraph 3.12 Status of Documents 5 29/09/2014 Indication document types allowed for upload
More informationLesson 4 Configuring the system. copy right reserved by GoodWe
51 3. Run the APP EzManage. 4. Series Selection Page: When the APP is first used, it will pair with the inverter automatically when connecting to the inverter s WiFi. If the APP stays at the series selection
More informationTechnical information for LFU20-Z07-3A-X2
Technical information for LFU20-Z07-3A-X2 Ultrasonic flow sensor and flow controller Applications: closed-loop flow control. Also requires fluid regulator (separate part) Ultrasonic flow sensor IN18796_LFU
More informationSeries description: Wilo-DrainLift KH 32
Series description: Wilo-DrainLift KH 32 H[m] Wilo-DrainLift KH 32 4 3 2 1 Design Small sewage lifting unit (floor-mounted installation) Application Sewage lifting unit ready for connection for limited
More informationFluid Flow Conditioning
Fluid Flow Conditioning March 2014 Flow Conditioning There is no flow meter on the market that needs flow conditioning. All flow meters are effective without any type of flow conditioning. 1 Flow Conditioning
More informationQuaSAR Quantitative Statistics
QuaSAR Quantitative Statistics QuaSAR is a program that aids in the Quantitative Statistical Analysis of Reaction Monitoring Experiments. It was designed to quickly and easily convert processed SRM/MRM-MS
More informationMINI-VERTICUS & VERTICUS THE NEXT GENERATION COMPRESSORS FOR SPORTS & SAFETY APPLICATIONS
MINI-VERTICUS & VERTICUS THE NEXT GENERATION COMPRESSORS FOR SPORTS & SAFETY APPLICATIONS SPORTS & SAFETY 2 MINI-VERTICUS & VERTICUS BAUER KOMPRESSOREN MINI-VERTICUS & VERTICUS STATIONARY COMPRESSORS REINVENTED
More informationACO Water Management: Civils + Infrastructure
ACO Water Management: Civils + Infrastructure Uniclass L3 + L735 CI/SfB (5.5) EPIC J343 ACO MultiDrain MD ACO MultiDrain MD channel drainage system Technical Data ACO MultiDrain MD Introduction to the
More informationAXi-GMBOX1 INSTALLATION MANUAL
AXi-GMBOX1 INSTALLATION MANUAL PLEASE REVIEW THIS INSTALLATION MANUAL CAREFULLY BEFORE BEGINNING ANY WORK COMPATIBLE PLUG & PLAY WIRING HARNESSES AXI-GM1-C AXI-GMMLX-C AXI-GMQUAD1-C AXI-GMDTS-C AXI-GMSTS-C
More informationTROJAN BATTERY COMPANY Renewable Energy Warranty Claim Form
Date: CUSTOMER INFORMATION Name: Address: City: Country: Email: Company: State: Phone: Fax: TO RECEIVE WARRANTY SUPPORT FOR TROJAN BATTERY PRODUCTS USED IN RENEWABLE ENERGY APPLICATIONS, THE FOLLOWING
More informationInstallation and Operating Procedures
Installation and Operating Procedures Manual Grease Interceptors 60100H SERIES 60210A SERIES Josam Company 525 W.U.S. Hwy 20 Michigan City, IN 46360 1-800-365-6726 www.josam.com REV A 04/15/11 WARNING:
More informationSUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514
SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514 INTRODUCTION Thank you for purchasing this CLARKE submersible pump. Before attempting to use the pump, please read this manual thoroughly
More informationSUBMERSIBLE WATER PUMPS
SUBMERSIBLE WATER PUMPS Model Nos. CS85S - CS85SA CS120S - CS120SA CS185S - CS185SA CS240S - CS240SA CS305S - CS305SA OPERATING & MAINTENANCE INSTRUCTIONS 1000 CONTENTS Warranty conditions... 3 Safety
More informationGPI (Gas Pump Interface) with Cash Register Express - Integration Manual
One Blue Hill Plaza, Second Floor, PO Box 1546 Pearl River, NY 10965 1-800-PC-AMERICA, 1-800-722-6374 (Voice) 845-920-0800 (Fax) 845-920-0880 GPI (Gas Pump Interface) with Cash Register Express - Integration
More informationHAND SPRAYER. MODEL NO: PHS8 Part No: OPERATING & MAINTENANCE INSTRUCTIONS GC0513
HAND SPRAYER MODEL NO: PHS8 Part No: 3402267 OPERATING & MAINTENANCE INSTRUCTIONS GC0513 INTRODUCTION Thank you for purchasing this CLARKE Sprayer, designed for use with insecticides or other water-based
More informationExcerpt from Chapter 3 of the City Code that address Fats, Oils and Grease (FOG) control program that was adopted by the City Council on May 9, 2016.
Excerpt from Chapter 3 of the City Code that address Fats, Oils and Grease (FOG) control program that was adopted by the City Council on May 9, 2016. Subd. 11. Grease Interceptors. A. Grease interceptors
More informationSix years in the making. The world s most sophisticated MPPT controller
MPPT Controllers Six years in the making The world s most sophisticated MPPT controller The Classic Lite. 96 amps for the price of 60! The MidNite Classic Incorporates things we have learned by producing
More informationIBM CMM Quick Reference Guide
IBM CMM Quick Reference Guide Contents Introduction Prerequisites Requirements Components Used CMM Overview CMM Layout Useful CMM Screens Login Screen System Information Screen Event Log Screen Chassis
More informationSeries 009. Reduced Pressure Zone Assemblies. Installation Service Repair Kits Maintenance. Sizes: 8 80mm. 80mm 009LF RP/IS-009-AUS
Series 009 Reduced Pressure Zone Assemblies RP/IS-009-AUS Sizes: 8 80mm Installation Service Repair Kits Maintenance For other repair kits and service parts, send for PL-RP-BPD. For technical assistance,
More informationRUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION
RUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION Introduction Congratulations and thank you for purchasing Marlec s HRDi Charge Regulator. This is the latest technology for charge regulation of
More informationWind power inverter WINDY BOY 5000-US/6000-US WINDY BOY 7000-US/8000-US. 1 Notes on this addendum. 1.1 Validity. 1.2 Target group
Wind power inverter WINDY BOY 5000-US/6000-US WINDY BOY 7000-US/8000-US Addendum operating requirements 1 Notes on this addendum 1.1 Validity This addendum does not replace the attached Sunny Boy installation
More informationVehicle CAN Database. Porsche 911 (991) GT3 Cup Gen1 - Bosch Connector
Vehicle CAN Database Porsche 911 (991) GT3 Cup Gen1 - Bosch Connector Overview Racelogic have acquired CAN signals for customers to use with VCI (Vehicle CAN Interface) products. This information is available
More informationLX-SERIES Low-Pressure Gas Compressors
70 to 140 psi Inlet Pressure Pressure 1500 PSI 70 80 90 100 110 120 130 140 C1.5-03-70/140LX 3 3.9 4.4 5.0 5.4 5.8 6.3 6.9 7.3 C1.5-05-70/140LX 5 6.4 7.2 8.1 8.7 9.4 10.3 11.3 11.9 C1.5-10-70/140LX 10
More informationLX SERIES Low-Pressure Gas Compressors
70 to 140 psig Inlet Pressure Pressure 1500 PSI 70 80 90 100 110 120 130 140 C1.5-03-70/140LX 3 3.7 4.2 4.6 5.0 5.5 5.9 6.4 6.8 C1.5-05-70/140LX 5 6.1 6.8 7.6 8.3 9.0 9.7 10.4 11.1 C1.5-10-70/140LX 10
More informationIntroduction to Inline Lubrication. Master Pneumatic
Introduction to Inline Lubrication Master Pneumatic What is the purpose of Inline Lubrication? Sentry Introduce atomized oil into the compressed air line to lubricate: Air Motors Cylinders Gears Sliding
More informationECUSimLite System User Manual
1 ECUSimLite System User Manual Table of contents 2 1. Introduction 3 1.1. Modes 3 1.2. Kit Contents 3 2. ECUSimLite Block Diagram 4 2.1. Connection Sequence 4 2.2. Getting Started 5 2.2.1. Set Range 6
More informationQuaSAR Quantitative Statistics
QuaSAR Quantitative Statistics QuaSAR is a program that aids in the Quantitative Statistical Analysis of Reaction Monitoring Experiments. It was designed to quickly and easily convert processed SRM/MRM-MS
More informationPHYSICAL MODEL TESTS OF ICE PASSAGE AT LOCKS
Ice in the Environment: Proceedings of the 16th IAHR International Symposium on Ice Dunedin, New Zealand, 2nd 6th December 22 International Association of Hydraulic Engineering and Research PHYSICAL MODEL
More informationWORLD SOURCE ONE Battery Construction Features & Benefits:
WORLD SOURCE ONE Battery Construction Features & Benefits: 1 Unique Features and Benefits Exact Fit Battery Forged terminal post bushings resist acid leakage for improved life and performance Original
More information5 LITRE HAND SPRAYER
5 LITRE HAND SPRAYER MODEL NO: 5LS PART NO: 3402264 USER INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0718 - ISS 1 INTRODUCTION Thank you for purchasing this CLARKE Sprayer, designed for use with insecticides
More informationRainbow Distribution Box
Rainbow Distribution Box Notes Rainbow Distribution Box The Rainbow Distribution Box is a purpose designed DC power distribution box that is flexible to user requirements. It caters for up to 50 mm² battery
More informationThe Up-Flo Filter Stormwater Treatment System Operation and Maintenance Manual UP-FLO FILTER OPERATION AND MAINTENANCE MANUAL Table of Contents 3 Up-Flo Filter - Overview - General Product Description
More informationSUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2
SUBMERSIBLE WATER PUMP Model Nos. CSE400A Part No. 7231100 0917 iss 2 OPERATING & MAINTENANCE INSTRUCTIONS Thank you for purchasing this Clarke Submersible Pump. This highly efficient pump is designed
More informationV 2.0. Version 9 PC. Setup Guide. Revised:
V 2.0 Version 9 PC Setup Guide Revised: 06-12-00 Digital 328 v2 and Cakewalk Version 9 PC Contents 1 Introduction 2 2 Configuring Cakewalk 4 3 328 Instrument Definition 6 4 328 Automation Setup 8 5 Automation
More informationTHE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.
Series 909 Reduced Pressure Zone Backflow Preventers Sizes: 3 /4" 2" (20 50mm) Installation Service Repair Kits Maintenance No. 1 1 2" shown Patent Number 4,241,752 IMPORTANT: Inquire with governing authorities
More information2015 Porsche Carrera S Workshop Manual
2015 Porsche Carrera S Workshop Manual Porsche 911 Carrera (Type 996) Service Manual: 1999-2015 - Table of Contents - Free download as PDF File (.pdf), Text file (.txt) or read online for free. The table
More informationFLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)
FLOOD PROTECTION SHUT DOWN VALVE ( and smaller) 01/10 2 6 To Floor Drain L X JB11 4 FS99 5 Installed upstream of Reduced Zone Backflow Preventer. Normally Open Valve - Closes when discharge from RPZ Relief
More informationI N S T R U C T I O N M A N U A L
I N S T R U C T I O N M A N U A L Oval Gear Positive Displacement Mechanical Flowmeters Models: 3 (080), 3 (080E), 4 (100), 4 (100E) NSW TEL: (02) 9939 0711 FAX: (02) 9939 0411 QLD/PNG TEL: (07) 3204 9166
More informationLACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31
LACT MEASUREMENT Prepared By: Ken A. Steward. P.E. Linco-Electromatic, Inc. 4580 West Wall Street Midland, Texas 79703 The Operation of L.A.C.T. Units The simplest approach to the understanding of the
More information12 Volt DC Diaphragm Pumps Series 400
Page 1 of 6 12 Volt DC Diaphragm Pumps Series 400 More Information Index Description of Included Models Safety Listings Available Options Accessories Performance Flow Curve Fluid Compatibility Dimensions
More informationElectronic Control Valves
131 Series (Full Internal Port) 631 Series (Reduced Internal Port) MODEL Electronic Control Valves Model 131-01/631-01 Simple Proven Design Quality Solenoid Pilot Controls Ideal For SCADA Systems Multi-Function
More informationVariable Speed Pump and Drive Technical Guide
Variable Speed Pump and Drive Technical Guide 2011 Hayward Pool Products Version 2 Drive FW 1.02 Interface FW 2.56 residential Interface FW 1.01 commercial Table of Contents Safety Precautions Page 1 Installation
More informationFreefall metal detection system Vistus with separator FL
Freefall metal detection system Vistus with separator FL The space-saving model Separator FL benefits For maximum space-saving: the low installation height allows for especially short complete systems
More informationUser Guide Electronic Logging Device
Nero (ELD) On December 16, 2015, the U.S. Department of Transportation ( https://www.transportation.gov/ ) approved the final ruling for the use of s (ELDs) for driver Hours of Service (HOS) and Driver-Vehicle
More informationCIRCLE SEAL CONTROLS
CIRCLE SEAL CONTROLS ATKOMATIC SOLENOID VALVES INSTALLATION, MAINTENANCE, AND OPERATION INSTRUCTIONS 3000 SERIES Bronze, Normally Closed, Direct Lift Installation Instructions WARNING: These instructions
More informationVAD Variable Area Desuperheaters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationACO Qmax Unit size
ACO Qmax 50 ACO Qmax 50 ACO Qmax 50 The ACO Qmax 50 channel is manufactured from recycled MDPE which is lightweight, chemically resistant and extremely robust. Its circular bore, ed push fit channel connections
More informationGRUNDFOS WASTEWATER. S range kw. 50 and 60 Hz versions
GRUNDFOS WASTEWATER S range 1.65 5.0 kw 50 and 60 Hz versions Grundfos Powerful pumps for handling unscreened raw sewage Grundfos offers a complete range of highly dependable, powerful sewage pumps, designed
More informationPowerSTAR PS-2024-D. Maximum Power Point Tracking Solar Regulator. w w w. r o c s o l i d. c o m. a u. Contents
w w w. r o c s o l i d. c o m. a u PowerSTAR PS-2024-D Maximum Power Point Tracking Solar Regulator Contents 1 Quick Start Guide... 2 2 Specifications... 3 2.1 General Operation... 3 2.2 Absolute Maximum
More informationVENT SILENCER PRODUCT GUIDE
VENT SILENCER Copyright 200 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited. PRODUCT GUIDE PULSCO VENT SILENCER TABLE OF CONTENTS DESCRIPTION PAGE PULSCO VENT
More informationFUELLOX MARKETING PACK. Fuellox Information Pack. IOTIQ Pty Ltd PO Box 4644 North Rocks NSW 2151 Phone:
FUELLOX MARKETING PACK Fuellox Information Pack IOTIQ Pty Ltd PO Box 4644 North Rocks NSW 2151 Phone: 1300 557 3565 Digitally Enable any pump to operate with the Fuellox App system. Dear Customer, Thanks
More informationAdditional Instruction of _STOCK Firmware
Additional Instruction of 110119_STOCK Firmware Note : The main difference of 110119_STOCK firmware between 100518_STOCK firmware is: 110119_STOCK firmware has totally 60 degree effective timing (Boosting
More informationJUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS
APPLICATION The compli 1500 and 2500 tank systems have been designed for large industrial and communal wastewater volumes as well as for the connection of streets or other community effluent systems. In
More informationFirst Defense. Stormwater Treatment System. Operation and Maintenance Manual
First Defense Stormwater Treatment System Operation and Maintenance Manual First defense OPERATION AND MAINTENANCE Table of Contents 3 First Defense by Hydro International - Benefits of the First Defense
More information1/2" AIR DRIVEN DIAPHRAGM PUMP
1/2" DRIVEN DIAPHRAGM PUMP OPERATION AND SERVICE GUIDE O-1225D NOV. 2008 Page 1 of 6 Refer to Bulletin P-605, Parts List P-9151 DRIVEN, DOUBLE DIAPHRAGM PUMP MANUAL Congratulations on purchasing one of
More informationRAINWATER HARVESTING INSTALLATION GUIDE RH High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application
RAINWATER HARVESTING INSTALLATION GUIDE RH9521-12 High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application RH9521-12 Vortex Filter Operation and Maintenance Overview The RH9521-12
More informationThe Next generation of Entry Level Fuel Management Solutions
The Next generation of Entry Level Fuel Management Solutions What is Sapphire Lite? 2 What is Sapphire Litefueller? 3 Introducing the next generation of entry level Fuel Management terminals, the Sapphire
More informationUsing Apollo Solar Remote Monitoring Software
Using Apollo Solar Remote Monitoring Software Apollo Solar, Inc. 23 F. J. Clarke Circle Bethel, Connecticut 06801 USA +1 (203) 790-6400 www.apollosolar.com 1 Overview We will see how all the components
More informationDRD - DRS - DRF. SUBMERSIBLE ELECTRIC PUMPS FOR SEWAGE in cast iron
DRD Cast iron submersible electric pumps for sewage with impeller with several channels APPLICATIONS Moving sewage, foul liquids in general Emptying seepage water Emptying cesspits Draining excavations
More informationfirst flust water diverters water quality first downpipe, post/wall mounted and in-ground diverters
water quality first downpipe, post/wall mounted and in-ground diverters Available in kit form just add PVC pipe Simple, effective and easy to install Includes Slow Release Control Valve - empties after
More information