1 Product Data Sheet PDS 340.B01 May, 2010 Oxymitter Now Offered With Xi Advanced Electronics In Situ Oxygen Transmitter Outstanding accuracy Electronics mounted to probe or separate Optional Xi advanced electronics large backlit LCD display advanced software features Wireless - via THUM TM Adaptor Adaptable to any existing O 2 probe installation Advanced sensor diagnostics alarm indicates when calibration is recommended Optional explosion-proof ratings see PDS C01 Digital HART or FOUNDATION fieldbus communications AMS/PlantWeb compatible Fully field-repairable Variable probe insertion option THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS The Oxymitter In Situ Oxygen Transmitter was the world s first in situ, zirconium oxide-based oxygen transmitter for flue gas measurement. These oxygen measurements can be used in a control system or by a boiler operator to fine tune burner fuel/air ratios for maximum efficiency. Ideal for: boilers process heaters kilns reheat furnaces Emerson Process Management is the leader in oxygen flue gas analyzer technology. Our in situ, zirconium oxide oxygen analyzers have long been established as industry standards. We ve combined our expertise with the latest Rosemount transmitter technology to create a truly revolutionary package the Oxymitter. The Oxymitter integrates an oxygen probe and field electronics into a single, compact package. The probe inserts directly into a flue gas duct to measure oxygen in combustion processes. No sampling system is required. A NEMA 4X, IP 66 Rosemount transmitter housing mounts directly to the probe and contains the transmitter s electronics, replacing common stand-alone field electronics. This integrated design minimizes the costs of installing separate probe cable, conduit and electronics. Wireless THUM TM Adaptor mounts to either electronics Integral or Remote electronics Optional Xi enhanced interface The Oxymitter electronics also require 95% less power to operate. So, its components last longer. Traditional architecture with remote-mounted electronics is also offered. The HART protocol provides a link into Emerson Process Management s PlantWeb field-based architecture. Instrument technicians can interface with the Oxymitter from the control room or any location where the transmitter s signal wires terminate. Service diagnostics and calibrations can be performed remotely with a HART hand-held communicator or a personal computer equipped with AMS. The Oxymitter is fully field-repairable. The probe s design provides convenient access to internal probe components so technicians can service the unit in house. The cell and heater/thermocouple are fully field-replaceable. The Oxymitter contains no potentiometer adjustments or jumpers. The Oxymitter In Situ Oxygen Transmitter operates at process temperatures up to 1300 F (700 C), providing a fast response with high accuracy and reliability. Available lengths from 18 inches to 18 feet. Optional accessories for the Oxymitter include: auto calibration gas sequencer remote, loop-powered Vacuum Fluorescent display of oxygen reading high temperature accessories for temperatures up to 1832 F (1000 C) flame arrestor abrasive shield Visit our website at On-line ordering available.

2 VARIABLE INSERTION OPTION The new varible insertion option permits ideal placement of the probe into the flue gas duct. Probe can be adjusted at any time on-line to characterize stratification across large ducts. THE OXYMITTER OXYGEN TRANSMITTER IS COMPLETELY FIELD-REPAIRABLE Diffusion Filter and Sensor Cell Assembly Outstanding accuracy + or -.75% of reading or.05% O 2 Special cells for tough service in SO 2 and HCL Rugged steel cell holder cells will not crack Heater/Thermocouple Assembly General Purpose OXT4A/5A Lengths from 18 (.9m) to 18 (5.5m) ANSI, DIN and special flanges (1.8m) (5.5m) Flat-faced (snubber), Hastelloy and Ceramic Diffusers Electronics -40 F to 185 F(-40 C to 70 C) ambient temperature limit HART or Foundation fieldbus communications Calibration Recommended diagnostic Integral to Probe or Remote Mounted Xi Enhanced Interface Lowest cost of installation Bright gas fluorescent local operator interface (LOI) Thru-glass infrared pushbuttons are suitable for hazardous areas Page 2 Easy-to-read backlit display Easy-to-use keypad IP66 (NEMA 4X) enclosure Advanced software features Loss of flame relay option turns heater off upon flame loss

3 Advanced Features Automatic Calibration - available with Oxymitter or Xi electronics Plant personnel often ask how frequently an oxygen analyzer requires calibration. The answer is very application-dependent based upon the fuels being burned, normal levels of oxygen and the sulfur content in the flue gases. The X-STREAM Xi addresses this concern by providing an on-line diagnostic that determines when a calibration should be conducted, eliminating many unneeded calibrations and the technician and gas resources they consume. The X-STREAM electronics has an on-line impedance measurement for the sensing cell. This feature can trigger a fully automatic calibration by sequencing solenoids to introduce calibration gases to the sensing cell. The Single Probe Sequencer (SPS) switches CAL gases to a single probe, while a Multi-Probe Sequencer (IMPS) can handle 1 to 4 probes. Many needless calibrations based on time in service are eliminated. A contact closure notifies the control room when a calibration is taking place. The oxygen output signal can be held at its last value, or released during calibration. The X-STREAM can also initiate calibrations by traditional methods: Contact closure from the user s control room Time since last calibration feature established by the autocalibration system Xi enhanced interface HART/AMS Oxymitter or Xi Enhanced Interface and Advanced Feature Electronics Single Probe Sequencer (SPS) Model 375/475 Handheld Communicator Optional Wireless THUM Adaptor Transmit the O 2 signal, along with all HART information. Page 3

4 Advanced Software features (available only with the Xi electronics) Extended Process Temperature Range to 800 C (1562 F) The X-STREAM oxygen analyzer employs a heater and thermocouple to maintain a temperature setpoint at 736 C (1357 F). Temperature control is maintained within ±1 C to process temperatures of about 705 C (1300 F). This is satisfactory for most applications, but excursions to higher temperatures can occur in many processes. In these instances, the heater is turned off and the process temperature is utilized to heat the sensing cell. Stoichiometer Process upsets can sometimes cause a combustion process to go into substoichiometric or reducing conditions. The oxygen readings from one or more probes may decline all the way to zero. The stoichiometer cell will measure the amount of oxygen deficiency during these reducing conditions. The trends in your DCS can be set up for a lower range limit of -1 or -2% oxygen to depict the level of oxygen deficiency. The oxygen reading is adjusted immediately to compensate for the varying process temperatures. It should be noted that cell life will be reduced by continuous operation at temperatures above 705 C (1300 F). If process temperatures are expected to continuously be above 705 C, we recommend the use of a bypass or probe mounting jacket accessory (see page 10). The operator can see if his control actions to recover are having the desired effect. These types of events do not occur frequently, but knowing the parameters of the situation prevents overcorrecting while coming out of the reducing condition. Acid-Resistant Stoichiometer Cell Typical DCS Trend During a Reducing Process Event DCS Trend With X-STREAM Stoichiometer Feature Programmable Reference The zirconium oxide sensing technology has historically measured process oxygen by using ambient or instrument air as a reference (20.95% oxygen). The sensor develops most of its signal at the low oxygen levels typically found in combustion flue gases (2-4% oxygen) and is most accurate at these levels. When measuring at levels near ambient, however, the sensor develops only a few millivolts of signal and accuracy degrades. The programmable reference feature permits the user to use a bottled reference gas of low oxygen value (.4% oxygen recommended). When measuring at or near 21% oxygen, a strong negative oxygen signal results with much improved accuracy. A bottle of reference gas typically lasts about a month at the low flows required. Typical applications include: Flue Gas Recirculation controlling the mixing of flue gases into the burner windbox prior to the burner to reduce NOx emissions. Moisture Monitoring measuring the amount of moisture coming off of industrial dryers by noting the dilution effect water vapor has on the normal 20.95% ambient drying air. Enriched Oxygen Combustion Pure oxygen is sometimes mixed in with the combustion air to increase heat at the flame. This is used in steel and other metals reduction processes and also in some catalyst regenerators. Page 4

5 SPECIFICATIONS 1 Measurement Specifications Net O 2 Range: variable 0-10% to 0-40% (Xi electronics offer 0-50% O 2 range) Accuracy in Oxidizing conditions: ±0.75% of reading or 0.05% O 2, whichever is greater Lowest detectable limit.02% O 2 Process Temperature Effect less than.05% O 2 from C System Speed of Response to Calibration Gas: Calibration Validity: Initial response in less than 3 seconds, T90 in less than 8 seconds. Response to process gas changes will vary, depending on process gas velocity and particulate loading of the diffuser Presentation of calibration gases matches the normal process to within ±.02% O 2 Accuracy in reducing conditions: ±.10% of reading, or.1% O 2, whichever is greater System Response in Reducing Conditions: going from oxidizing to reducing -T90 in 120 sec. going from reducing to oxidizing -T90 in 30 sec. Environmental Specifications Transmitter Probe: Process-wetted materials are 316L or 304 stainless steel Process Temperature Limits: Oxymitter Transmitter Electronics Housing (integral to probe, or remote mounted): General Purpose Certifications: Oxymitter electronics ambient temp. Limits: 0 to 705 C ( F) with Oxymitter electronics 0 to 800 C ( F) with Xi electronics *reduced cell life can be expected if operated continously at tempatures above 705 C (1300 F) optional bypass and jacket accessories permit operation to 1050 C (1922 F) Low copper aluminum IP 66 (NEMA 4X), with reference air exhuast port piped to clean area -40 to 80 C (-40 to 176 F) Temperature limit as measured inside Oxymitter electronics: -40 to 85 C (-40 to 185 F) Temperature limit of see-thru IR pushbuttons: Optional Xi Electronics: -40 to 70 C (-40 to 158 F) NEMA 4X, Polycarbonite Material General Purpose Certifications: Xi Ambient Temp. Limits: Xi Temp. Limits as measured inside the housing: Xi LCD display Temp. Limits: Installation Specifications -20 to 55 C (-4 to 131 F) -20 to 55 C (-4 to 113 F) -20 to 55 C (-4 to 131 F) Probe Mounting Flange: vertical or horizontal 2 150# (4.75 (121mm) bolt circle) DIN (145mm (5.71 ) bolt circle) Note: flanges are flat-faced, and for mounting only. Flanges are not pressure-rated. Spool piece P/N 3D39761G02 is available, to offset electronics housing from hot ductwork. Many adaptor flanges are available to mate to existing flanges. Probe Lengths and Approximate Shipping weights: 18 in. (457 mm) package: 16 pounds (7.3 kg) 3 foot (0.91 m) package: 21 pounds (9.5 kg) 6 foot (1.83 m) package: 27 pounds (12.2 kg) 9 foot (2.74 m) package: 33 pounds (15.0 kg) 12 foot (3.66 m) package: 39 pounds (17.7 kg) 15 foot (4.6 m) package: 45 pounds (20.5 kg) 18 foot (5.5 m) package: 51 pounds (23 kg) Reference Air (optional): Calibration: 2 scfh (1l/m), clean, dry, instrument quality air (20.95% O 2 ), regulated to 2.5 psi (34kPa) Semi-automatic or automatic Cal Gases:.4% O 2 and 8%, balance N 2 recommended Cal Gas Flow: 5 scfh (2.5 l/m) Heater Electrical Power: V, ±10% 50/60 Hz 1/2 14 NPT conduit ports Traditional Architecture Cable: Power Consumption of Probe Heater: Electrical Power of Oxymitter or optional Xi electronics: Power Consumption of Xi: Xi Alarms Relays: Xi Optional Loss of Flame Contact: 200 foot (61m) maximum length 776VA maximum during warm-up 120 to 240V, ±10% 50/60 Hz 10 watts maximum 2 provided - 2 amps, 30 VDC Removes heater power Page 5

6 Electrical Noise: Meets EN 61326, Class A Traditional Architecture Cable: 200ft (61m) maximum length Power Consumption of Probe Heater: 776VA maximum during warm-up Transmitter Electrical Power: 12 42VDC, (loop-powered from the control room or from the Xi box) General Purpose HART communications - OXT4A pg. 11 FOUNDATION Fieldbus Communications - OXT5A pg. 13 Direct Replacement Probe (for use with existing electronics) - OXT4ADR pg. 15 Automatic calibration systems - XSO 2 Cal pg. 16 Optional Xi advanced electronics - Xi pg. 17 Power Supply and Load Requirements Electrictical Power for Xi: Power Consumption of Xi: Alarm Relay Outputs: Optional Loss of Flame Input: V ±10%, 50-60Hz 12VA maximum or 776VA maximum with Traditional Architecture, 120V, Probes. 450VA maximum with Traditional Architecture, 44V Probes Two provided - 2 Amperes, 30 VDO, Form-C internally powered input to remove heater power, actuated via dry contact output from prove of flame device. Emerson Process Management has satisfied all obligations coming from the European legislation to harmonize the product requirements in Europe. 1 All static performance characteristics are with operating variables constant. Specifications subject to change without notice. Page 6

7 OUTLINE DIMENSIONS FOR OXYMITTER OXYGEN TRANSMITTER FOR GENERAL PURPOSE APPLICATIONS (OXT4A, OXT5A, OXT4ADR) Table I. Mounting Plate Dimensions Dia. in. (mm) ANSI DIN JIS Mtg. Plate (x) (153) (190) (165) Stud Size 5/8 11 M16 x 2 M12 x Studs Eq BC 5.71 BC 5.12BC Sp. on BC (121) BC (145) BC (130) BC Flange (Y) (153) (185) (155) Table II. Removal/Installation Dim A Dim. B Probe Insertion Removal Length Depth Envelope 18 in. (457 mm) Probes (407) (725) 3 ft. (0.91 m) Probes (864) (1182) 6 ft. (1.83 m) Probes (1778) (2097) 9 ft. (0.91 m) Probes (2692) (3011) 12 ft. (3.66 m) Probes (3607) (3926) Page 7

8 OXYMITTER 4000 WITH ABRASIVE SHIELD ATMO E R WAV LOSI SP NING- R HE E - VE I AL T I U C CIR WHEN XP - E TI GHT N I - KE P E Notes : 0.2 (5) 3.9 (99) S nubber/dust S eal Assembly Deflector Assy P robe (330) 31 (787) 67 (1702) 103 (2616) 139 (3531) 175 (4445) 211 (5359) (826) 50.5 (1283) 86.5 (2197) (3112) (4026) (4940) (5855) Diffuser/Dust S eal Assy and 7.00 (178) F lange A NS I DI N Flange Dia Hole Dia 9.00 (229) 0.75 (19) 9.25 (235) 0.94 (24) 7.50 (190) 7.48 (190) R emoval 4.77 (121) 6.02 (153) E nvelope (318). G CAL AS R ef ANS I DIN Air C onnection Note: For probes 9 ft. or longer, bracing for cell end of probe is required inside the flue gas ductwork. (Brackets provided with abrasive shield) Page 8

9 OXYMITTER 4000 ADAPTOR PLATE WITH ABRASIVE SHIELD Dimensions in. (mm) ANS I DIN "A" " B" Dia "C " Thread " D" Dia 9.00 (229) 4.75 (121) (191) 9.25 (235) 3.94 (100) 7.48 (190) 22.5 o A A B C Page 9

10 OPTIONAL VARIABLE INSERTION MOUNTING* (OXT4A, OXT5A, OXT4ADR) PROBE SIZE L D X1 ±2 (51) X2 ±2 (51) 9 ft. (2.73) 118 (2997) 18 (457) < D<103 (2616) 72 (1829) 12 ft. (3.64) 154 (3912) 18 (457) < D<139 (3531) 60 (1524) 120 (3948) 15 ft. (4.55) 190 (4826) 18 (457) < D<175 (4445) 70 (1778) 150 (3810) 18 ft. (5.45) 226 (5740) 18 (457) < D<211 (5359) 80 (2032) 160 (4064) Page 10 *Note - cannot be used with abrasion shield, not recommended for highly abrasive flue gases order by part #6A00319G03

11 ORDERING INFORMATION General Purpose Oxymitter with 4-20 ma Output Signal, and HART Communications. Optional Xi electronics not applicable. Model Description OXT4A In Situ Oxygen Transmitter HART Smart (Oxymitter 4000) Level 1 Sensing Probe Type 1 Ceramic diffusion element probe (ANSI) 3 Snubber diffusion element (ANSI) 4 Ceramic diffusion element probe (DIN) 6 Snubber diffusion element (DIN) 7 Ceramic diffusion element probe (JIS) 9 Snubber diffusion element (JIS) Level 2 Level 3 Level 4 Probe Assembly 0 18 (457mm) probe 1 18 (457mm) probe with abrasive shield 2 3 (0.91m) probe 3 3 (0.91m) probe with abrasive shield 4 6 (1.83m) probe 5 6 (1.83m) probe with abrasive shield 6 9 (2.74m) probe 7 9 (2.74m) probe with abrasive shield 8 12 (3.66m) probe 9 12 (3.66m) probe with abrasive shield A 15 (4.57m) probe with abrasive shield B 18 (5.49m) probe with abrasive shield Mounting Hardware (stack side) 0 No mounting hardware 1 New Installation square weld plate with studs 2 Mounting to Model 218 mounting plate (with Model 218 shield removed) 3 Mounting to existing Model 218 support shield 4 Mounting to other mounting 5 Mounting to Model 132 adapter plate Mounting Hardware (probe side) 0 No mounting hardware 1 Probe only (ANSI) 2 New bypass or new abrasive shield (ANSI) 4 Probe only (DIN) 5 New bypass or new abrasive shield (DIN) 7 Probe only (JIS) 8 New bypass or new abrasive shield (JIS) Level 5 Electronic Housing and Filtered Customer Termination NEMA 4X, IP For HART electronics integrally mounted to probe with transient protected filtered termination no cable required 14 For HART electronics mounted remotely with transient protected filtered termination must select cable below Level 6 Communications 1 Membrane keypad HART capable, blind cover 2 Membrane keypad HART capable, glass cover 3 Gas fluorescent LOI HART capable, glass cover, English only Page 11

12 ORDERING INFORMATION (continued) Level 7 Level 8 Level 9 Level 10 Language 1 English 2 German 3 French 4 Spanish 5 Italian Termination Filtering 00 Specified as part of electronic housing Calibration Accessories 00 No hardware 01 Cal./ref. flowmeter and ref. pressure regulator 02 Autocalibration Systems order by separate part number (for safe areas only) Electronics to Probe Cable 00 No cable integral electronics (6m) cable remote electronics (12m) cable remote electronics (18m) cable remote electronics (24m) cable remote electronics (30m) cable remote electronics (45m) cable remote electronics (61m) cable remote electronics Page 12

13 ORDERING INFORMATION General Purpose Oxymitter with FOUNDATION Fieldbus Communications. Optional Xi electronics not applicable. Model Description OXT5A In Situ Oxygen Transmitter with FOUNDATION fieldbus (Oxymitter 5000) Level 1 Sensing Probe Type 1 Ceramic diffusion element (ANSI) 3 Snubber diffusion element (ANSI) 4 Ceramic diffusion element (DIN) 6 Snubber diffusion element (DIN) 7 Ceramic diffusion element (JIS) 9 Snubber diffusion element (JIS) Level 2 Level 3 Level 4 Probe Assembly 0 18 (457mm) probe 1 18 (457mm) probe with abrasive shield 2 3 (0.91m) probe 3 3 (0.91m) probe with abrasive shield 4 6 (1.83m) probe 5 6 (1.83m) probe with abrasive shield 6 9 (2.74m) probe 7 9 (2.74m) probe with abrasive shield 8 12 (3.66m) probe 9 12 (3.66m) probe with abrasive shield A 15 (4.57m) probe with abrasive shield B 18 (5.49m) probe with abrasive shield Mounting Hardware (stack side) 0 No adapter plate 1 New Installation square weld plate with studs 2 Mounting to Model 218 (with Model 218 shield removed) 3 Mounting to existing Model 218 support shield 4 Competitor s mount 5 Mounting to Model 132 adapter plate Mounting Hardware (probe side) 0 No mounting hardware in adapter plate 1 Probe only (ANSI) 2 New bypass or new abrasive shield (ANSI) 4 Probe only (DIN) 5 New bypass or new abrasive shield (DIN) 7 Probe only (JIS) 8 New probe or abrasive shield (JIS) Level 5 Electronic Housing NEMA 4X, IP Transient protected filtered termination, integrally mounted to probe 14 Transient protected filtered termination, mounted remotely requires cable Level 6 Level 7 Communications/Operator Interface 1 Membrane keypad fieldbus, blind cover 2 Membrane keypad fieldbus, glass cover 3 Gas fluorescent LOI, fieldbus, glass cover Language 1 English 2 German 3 French 4 Spanish 5 Italian Page 13

14 ORDERING INFORMATION (continued) Level 8 Level 9 Level 10 Level 11 Termination Filtering 00 No option specified as part of electronic housing Calibration Accessories 00 No hardware 01 Cal. gas, flow rotometer and reference gas set 02 Autocalibration Systems order by separate part number (for safe areas only) Control Suite Functionality 00 Basic control suite 01 Deduct basic control suite Electronics to Probe Cable 00 No cable integral electronics ft. (6m) cable remote electronics ft. (12m) cable remote electronics ft. (18m) cable remote electronics ft. (24m) cable remote electronics ft. (30m) cable remote electronics ft. (45m) cable remote electronics ft. (61m) cable remote electronics Page 14

15 ORDERING INFORMATION Direct Replacement Oxymitter Probe replaces all older Westinghouse and Rosemount Analytical probes, as well as most competitive probes. Operates on most existing electronics, and also on the Xi enhanced interface electronics. Model OXT4ADR Description In Situ Oxygen Transmitter for use with existing electronics or Xi electronics Level 1 Sensing Probe Type 1 Ceramic diffusion element probe (ANSI) 3 Snubber diffusion element (ANSI) 4 Ceramic diffusion element probe (DIN) 6 Snubber diffusion element (DIN) 7 Ceramic diffusion element probe (JIS) 9 Snubber diffusion element (JIS) Level 2 Probe Assembly 0 18 (457mm) Probe 1 18 (457mm) Probe with abrasive shield 2 3 (0.91m) Probe 3 3 (0.91m) Probe with abrasive shield (1.83m) Probe 5 6 (1.83m) Probe with abrasive shield (2.74m) Probe 7 9 (2.74m) Probe with abrasive shield (3.66m)Probe (3.66m) Probe with abrasive shield 4 A 15 (4.57m) Probe with abrasive shield B 18 (5.49m) Probe with abrasive shield Level 3 Mounting Adapter Stack Side 2 0 No adapter plate 1 Mounting to stack (new installation) 2 Mounting to model 218/225/240 mounting plate (with probe support tube removed) 3 Mounting into existing model 218/225/240 probe support tube or bypass 4 Mounting into competitor s mounting 3 5 Model 132 / World Class 3000 adapter plate Level 4 Mounting Adapter Probe Side 0 No mounting hardware 1 Mounting probe only (ANSI) 2 Mounting probe with abrasive shield (ANSI) 4 Mounting probe only (DIN) 5 Mounting probe with abrasive shield (DIN) 7 Mounting probe only (JIS) 8 Mounting probe with abrasive shield (JIS) Level 5 Termination Unit 11 Standard filtered termination 12 Transient protected filtered termination Level 6 Arrangement-Existing Electronics 03 No hardware. For use with 218 analog electronics, world-class IFT electronics or Oxymitter electronics, Xi electronics 04 Westinghouse/Rosemount digital (218A) or universal electronics 05 VeriTrim electronics 07 Model 132 digital electronics 08 For use with Yokogawa electronics (cold junction comp. in probe junction box) 09 For use with other competitive oxygen analyzer systems Note: Order manual calibration accessories separately 263C152G01 Reference air regulator set 771B635H01 (2 required) flowmeters for calibration and reference air Page 15

16 Option Notes for Oxt4A, Oxt5A and Oxt4ADR Notes: In-Situ Oxygen Transmitter HART Smart High Sulfur Service: High sulfur cell can be selected for any probe; add a line item note to your purchase order requesting the high sulfur ZrO2 cell in place of the standard ZrO2 cell. Add 4232 UOM to the system matrix UOM total. Example: Note: Delete standard cell P/N 4847B63G01 Add high sulfur cell P/N 4847B63G02 Cell replacement kits for high sulfur service are also available. Consult P/N 4849B94XX in the Combustion Solutions Center Spare Parts list. Level 2: Option: 0 25/55 kgs/lbs shipping weight Level 2: Option: 2 27/60 kgs/lbs shipping weight Level 2: Option: 4 30/66 kgs/lbs shipping weight Level 2: Option: 6 33/72 kgs/lbs shipping weight Level 2: Option: 8 35/78 kgs/lbs shipping weight Level 2: Option: 3 45/100 kgs/lbs shipping weight Level 2: Option: 5 50/110 kgs/lbs shipping weight Level 2: Option: 1, 7 54/120 kgs/lbs shipping weight Level 2: Option: 9 60/130 kgs/lbs shipping weight Level 2: Option: A 66/145 kgs/lbs shipping weight Level 2: Option: B 72/158 kgs/lbs shipping weight Level 2: Option: 1, 3, 5, 7, 9, A, B Recommended usages: high velocity particulates in flue stream, installation within 10 (3.5 m) of soot blowers or heavy salt cake build up. Applications: pulverized coal, recovery boilers, lime kiln. Regardless of application, abrasive shields with support brackets are recommended for 9 (2.74 m) and 12 (3.66 m), 16 (4.57 m) and 18 (5.49 M) probe installations, particularly horizontal installations. Level 3: Option: 4 Where possible, specify SPS number, otherwise provide details of the existing mounting plate as follows: Plate with studs: Bolt circle diameter, number and arrangements of studs, stud thread, stud height above mounting plate. Plate without studs: Bolt circle diameter, number and arrangement of holes, thread, depth of stud mounting plate with accessories. Level 6: Option: 1 Startup, calibration and operation can be implemented using the standard membrane keypad. Remote access and additional functionality available via HART /FOUNDATION Field Communications (Model 375 Hand-held Communicator or AMS) with Oxymitter device descriptor (DD) required. ORDERING INFORMATION AUTOCALIBRATION ACCESSORIES Model XSO2CAL Level 1 Level 2 Description O 2 Autocalibration Accessories - apply to Oxymitter or Xi electronics. General purpose only. Single Probe Sequencers Autocalibration options 00 None 01 SPS 4001 Single Probe Sequencer, general purpose NEMA 4X, includes check valve for probe Intelligent Multiprobe Sequencers (IMPS) 00 None 01 IMPS Intelligent Probe Sequencer, single-probe, general purpose NEMX 4X, includes valve for probe 02 IMPS Intelligent Probe Sequencer, two-probe, general purpose NEMX 4X, includes valve for probe 03 IMPS Intelligent Probe Sequencer, three-probe, general purpose NEMX 4X, includes valve for probe 04 IMPS Intelligent Probe Sequencer, four-probe, general purpose NEMX 4X, includes valve for probe 05 IMPS Intelligent Probe Sequencer, single-probe, 115V heated general purpose NEMX 4X, includes valve for probe 06 IMPS Intelligent Probe Sequencer, two-probe, 115V heated general purpose NEMX 4X, includes valve for probe 07 IMPS Intelligent Probe Sequencer, three-probe, 115V heated general purpose NEMX 4X, includes valve for probe 08 IMPS Intelligent Probe Sequencer, four-probe, 115V heated general purpose NEMX 4X, includes valve for probe 09 IMPS Intelligent Probe Sequencer, single-probe, 220V heated general purpose NEMX 4X, includes valve for probe 010 IMPS Intelligent Probe Sequencer, two-probe, 220V heated general purpose NEMX 4X, includes valve for probe 011 IMPS Intelligent Probe Sequencer, three-probe, 220V heated general purpose NEMX 4X, includes valve for probe 012 IMPS Intelligent Probe Sequencer, four-probe, 220V heated general purpose NEMX 4X, includes valve for probe Page 16

17 ORDERING INFORMATION OPTIONAL Xi ADVANCED ELECTRONICS Model XI Level 1 Level 2 Level 3 Description O 2 Advanced electronics Xi Type 01 Future 02 Future 03 Future 04 Traditional Architecture Xi - all signal conditioning and operator interface via the Xi. Cable required, single channel only. 05 Traditional Architecture Xi - all signal conditioning and operator interface via the Xi. Cable required, single channel only, set up to run 44V world class probe Calibration & Reference Gas Accessories 00 No Hardware 01 Calibration & Reference Gas Flowmeters & Reference Regulator/Filter Cable (For Traditional Architecture Xi Only) 00 None (6m) Cable (12m) Cable (18m) Cable (24m) Cable (30m) Cable (45m) Cable (60m) Cable Level 4 Stoichiometer Function 00 No 01 Single Channel 02 Dual Channel Level 5 Programmable Reference Function 00 No 01 Single Channel 02 Dual Channel Level Deg C Process Function 00 No 01 Single Channel 02 Dual Channel NOTES: Order Direct Replacement Oxymitter probe separately - Oxt4ADR Page 17

18 Xi Enhanced Interface - Panel Mounting Details Xi Enhanced Interface - Wall/Surface and Pipe Mounting Details Page 18

19 OXYMITTER ACCESSORIES HART Hand-held 375 Communicator The FOUNDATION fieldbus 375 Communicator is an interface device that provides a common communication link to HART /FOUNDATION fieldbus compatible instruments, such as the Sulfur-Resistant Oxymitter. HART Communications Protocol permits all the information available from the Sulfur-Resistant Oxymitter electronics to be transmitted over standard 4-20 ma signal wires or FOUNDATION fieldbus wires. By attaching the hand-held communicator at a termination point along the signal line, a technician can diagnose problems and configure and calibrate the Sulfur-Resistant Oxymitter as if he or she were standing in front of the instrument. For more information, call Rosemount Analytical at Bypass Packages The specially designed Rosemount Analytical Bypass Package for oxygen analyzers has proven to withstand the high temperatures in process heaters while providing the same advantages offered by the in situ sensor. Inconel tubes provide effective resistance to corrosion, and the other components common to other sampling systems. For more information, call Rosemount Analytical at O 2 Calibration Gas Kits - pn. 6296A27G01 Rosemount Analytical s O 2 Calibration Gas and Service Kits have been carefully designed to provide a more convenient and fully portable means of testing, calibrating, and servicing Rosemount Analytical s oxygen analyzers. These lightweight, disposable gas cylinders eliminate the need to rent gas bottles. For more information, call Rosemount Analytical at Wireless THUM TM Adaptor The Smart Wireless THUM Adaptor converts the standard 4-20mA signal from the Xi electronics to a wireless signal. All HART information is transmitted in addition to the process O 2 value. For more information, call Rosemount Analytical at Page 19

20 SPECIAL ARRANGEMENTS Special Cells for High Acid Service Many combustion processes use fuels that contain sulfur of HCI. Special cells provide extended life in these difficult applications. Catalyst Regeneration Measure O 2 in regenerators at pressures up to 50 psi. In situ design resists plugging due to catalyst fines Class I, Div. I, Group B, C and D. Optional pressure balancing arrangement. Optional isolation valving system permits installation and withdrawal while the process is running. Specified by UOP. See Application Data Sheet ADS F.A01. Isolation Valving System O 2 Probe in Retracted Position Integral Pressure Balancing Assembly Pressure balanced in situ O 2 probe with optional isolation valving system (probe withdrawn) The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. To find the local Rosemount Analytical specialist near you, go to: 8 Rosemount Analytical Inc., All rights reserved. Printed in U.S.A. on recycled paper.

In Situ Oxygen Transmitter for Hazardous Area Applications

In Situ Oxygen Transmitter for Hazardous Area Applications Product Data Sheet PDS 340.C01 May, 2010 In Situ Oxygen Transmitter for Hazardous Area Applications Outstanding accuracy Electronics mounted to probe or separate Optional Xi advanced electronics large

More information

In Situ Oxygen Transmitter

In Situ Oxygen Transmitter Product Data Sheet PDS 06-340.A0 April, 2004 Oxymitter 4000 In Situ Oxygen Transmitter Now Offered With Remote Electronics! Outstanding accuracy Electronics mounted to probe or separate Adaptable to any

More information

In Situ Oxygen Transmitter

In Situ Oxygen Transmitter Product Data Sheet PDS 106-340.A01 January, 2005 Oxymitter Now Offered With Remote Electronics! In Situ Oxygen Transmitter Outstanding accuracy Electronics mounted to probe or separate Adaptable to any

More information

In Situ Oxygen Transmitter

In Situ Oxygen Transmitter Product Data Sheet PDS 06-340.A0 June, 2004 Oxymitter 4000 In Situ Oxygen Transmitter Now Offered With Remote Electronics! Outstanding accuracy Electronics mounted to probe or separate Adaptable to any

More information

In Situ Oxygen Transmitter

In Situ Oxygen Transmitter Product Data Sheet PDS 106-340.A01 September, 2007 Oxymitter Now Offered With Remote Electronics! In Situ Oxygen Transmitter Outstanding accuracy Electronics mounted to probe or separate Adaptable to any

More information

In Situ Oxygen Transmitter For High Sulfur Environments

In Situ Oxygen Transmitter For High Sulfur Environments Product Data Sheet PDS 106-340AS.A01 Sulfur Resistant Oxymitter March, 2000 In Situ Oxygen Transmitter For High Sulfur Environments Zirconium oxide-based cell is resistant to sulfur in the flue gas Unique

More information

OCX 8800 Oxygen/Combustibles Transmitter

OCX 8800 Oxygen/Combustibles Transmitter Instruction Manual OCX 8800 Oxygen/Combustibles Transmitter Hazardous Area OCX 8800 Oxygen/Combustibles Analyzer with Integral Electronics http://www.raihome.com Instruction Manual OCX 8800 Table of Contents

More information

World Class 3000 Oxygen Analyzer with IFT 3000 Intelligent Field Transmitter

World Class 3000 Oxygen Analyzer with IFT 3000 Intelligent Field Transmitter Instruction Manual IB-106-300NH Rev. 4.3 World Class 3000 Oxygen Analyzer with IFT 3000 Intelligent Field Transmitter http://www.raihome.com ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount

More information

Zirconia Oxygen Probe

Zirconia Oxygen Probe Data Sheet SS/ZFG Issue Zirconia Oxygen Probe ZFG Series Environmental Certification MCERTS SIRA Certificate MC99000 Combustion monitoring control true wet measurement of net excess oxygen in situ measurement

More information

Installation/Start-up Manual CMB_MAN_ABR_CH88 September CH88 In-Situ Combustion O2. Analyzer System

Installation/Start-up Manual CMB_MAN_ABR_CH88 September CH88 In-Situ Combustion O2. Analyzer System CH88 In-Situ Combustion O2 Analyzer System Section 1: Section 2: Section 3: Section 4: Section 5: Section 6: Contents General Information Essential Instructions... 2 Symbols used... 3 Overview... 4 System

More information

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter Instruction Manual April 2017 Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter General Purpose Probe with Integral Electronics and Local Operator Interface Page/Section Throughout Summary HIGHLIGHTS

More information

World Class 3000 Oxygen Analyzer with HPS Heater Power Supply Field Module (for use with Existing Signal Conditioning Electronics)

World Class 3000 Oxygen Analyzer with HPS Heater Power Supply Field Module (for use with Existing Signal Conditioning Electronics) Instruction Bulletin 106-300NE Rev. 3.4 May 2000 World Class 3000 Oxygen Analyzer with HPS Heater Power Supply Field Module (for use with Existing Signal Conditioning Electronics) http://www.processanalytic.com

More information

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter Reference Manual Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter General Purpose Probe with Integral Electronics and Local Operator Interface OCX 8800 Table of Contents Reference Manual Essential

More information

OCX 4400 OXYGEN/COMBUSTIBLES TRANSMITTER

OCX 4400 OXYGEN/COMBUSTIBLES TRANSMITTER Instruction Manual OXYGEN/COMBUSTIBLES TRANSMITTER http://www.processanalytic.com ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures and tests its products

More information

ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement

ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement Data sheet DS/ZMT/LO EN Rev. J ZMT & ZFG Superior technology and quality from the world leader in oxygen measurement Integral reference-air supply option avoids necessity for additional equipment Dual

More information

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter Reference Manual July 2018 Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter General Purpose Probe with Remote Electronics OCX 8800 Table of Contents Reference Manual July 2018 Essential Instructions...

More information

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter July 2018 Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter Hazardous Location Transmitter with Remote Electronics OCX 8800 Table of Contents July 2018 Essential Instructions... i Preface... ii

More information

OCX 8800 Oxygen/Combustibles Transmitter

OCX 8800 Oxygen/Combustibles Transmitter Oxygen/Combustibles Transmitter Hazardous Area Oxygen/Combustibles Analyzer with Remote Electronics http://www.raihome.com HIGHLIGHTS OF CHANGES Page/Section Throughout Summary Effective December 2007,

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

Combustion Gas Analysis

Combustion Gas Analysis Data Sheet DS/AZ EN Issue Combustion Gas Analysis Endura AZ Oxygen Monitor Advanced design and precision manufacturing robust, long-life probe for process temperatures up to 8 C (47 F) proven cell design

More information

Heavy-Duty Battery and Electrical System Diagnostic Tester

Heavy-Duty Battery and Electrical System Diagnostic Tester Sabre Heavy-Duty Heavy-Duty Battery and Electrical System Diagnostic Tester Heavy-duty for 24-volt battery and electrical systems Diagnoses battery packs in series, parallel, or series/parallel Test AGM/gel

More information

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand CAMS Combustion Airflow Management System Proven solutions for a tough industry Precision Airflow Measurement An ONICON Brand CAMS TM Combustion Airflow Management System Product Description The Air Monitor

More information

Model Q45H/ Residual Chlorine Monitor...

Model Q45H/ Residual Chlorine Monitor... Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking

More information

O 2 CO CO 2 NO NO 2 NO x

O 2 CO CO 2 NO NO 2 NO x continuous emissions monitoring O 2 CO CO 2 NO NO 2 NO x FGA 900 Series Combustion & Environmental Monitoring FGA Continuous Emissions & Combustion Efficiency Monitoring The FGA range of analyzers use

More information

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter INTERPLANT STANDARD - STEEL INDUSTRY IPSS Specification for Smart Pressure & Differential Pressure Transmitter Corresponding IS does not exist IPSS: 2-07-104-15 1. Scope 1.1 This Interplant Standard covers

More information

Dissolved Oxygen Measurement System with Air Blast Cleaner

Dissolved Oxygen Measurement System with Air Blast Cleaner Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays

More information

SPS 4000 Single Probe Autocalibration Sequencer

SPS 4000 Single Probe Autocalibration Sequencer Instruction Manual Single Probe Autocalibration Sequencer http://www.processanalytic.com ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, manufactures and tests its

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013 Product Data Sheet PDS 71-400/rev.K February 2013 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Factory-measured cell constant ensures out-of-the-box

More information

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 Series Flow Meters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 FLOW METER Wastewater Treatment Aeration Control Blower

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008 Product Data Sheet PDS 71-400/rev.I December 2008 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS Features/Benefits INSTALL IT & FORGET IT The ForceMeter TM offers the same rugged design for which the Niagara Meters brand is known. The ForceMeter is ideal for applications including water, compressed

More information

G2 Industrial Grade Meters

G2 Industrial Grade Meters G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine

More information

Rosemount 3051CFA Annubar Flowmeter

Rosemount 3051CFA Annubar Flowmeter December 2013 Rosemount 3051 Rosemount 3051CFA Annubar Flowmeter The Rosemount 3051CFA Annubar Flowmeter utilizes the patented T-shaped sensor design that delivers best in class accuracy and performance.

More information

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct MF200A Series Weather-Proof Thermal Mass Flow Meter for Pipe - Duct Feature & Application n Accuracy ±1.0% reading n Watch-dog software n Wide turn-down ratio 300 : 1 n Repeatability ±0.15% FS n 16 x 2

More information

General Purpose Toroidal Conductivity Sensors

General Purpose Toroidal Conductivity Sensors Product Data Sheet PDS 71-226/228/revF January 2011 Model 226 and 228 General Purpose Toroidal Conductivity Sensors NON-CONTACTING (TOROIDAL) SENSORS resist corrosion and fouling. SENSORS ARE IDEAL for

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

Rosemount 8750WB Magnetic Flowmeter System

Rosemount 8750WB Magnetic Flowmeter System Rosemount 8750WB Magnetic Flowmeter System for Utility, Water, and Wastewater Applications Product Data Sheet 00813-0200-4750 Rev AA THE 8750W MAGNETIC FLOWMETER Rosemount reliability customized for Water,

More information

Micro Motion ELITE Mass Flow and Density Meters

Micro Motion ELITE Mass Flow and Density Meters Product Data Sheet PS 00375 March 2002 Micro Motion ELITE Mass Flow and Density Meters Now available with MVD Technology! www.micromotion.com Micro Motion ELITE Meters Experience the most accurate Coriolis

More information

Royce Total Suspended Solids Systems. Water & Wastewater

Royce Total Suspended Solids Systems. Water & Wastewater Royce Total Suspended Solids Systems Water & Wastewater Portable and Continuous TSS Systems MODEL 711 PORTABLE MLSS/ILA SYSTEM FEATURES Two complete analyzers in one package (TSS & Interface Level) Microprocessor

More information

Combustion Control Problem Solution Combustion Process

Combustion Control Problem Solution Combustion Process Combustion Control Problem Until recent years, only the largest boilers could justify sophisticated combustion controls. Now, higher fuel costs and occasionally limited fuel availability make it necessary

More information

INTERNATIONAL METAL ENGINEERING

INTERNATIONAL METAL ENGINEERING INDICATING TEMPERATURE TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006 Product Data Sheet PDS 71-400/rev.G February 2006 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

Endura AZ20 oxygen monitor Combustion gas analysis. Superior technology and quality from the world leader in oxygen measurement

Endura AZ20 oxygen monitor Combustion gas analysis. Superior technology and quality from the world leader in oxygen measurement Data sheet DS/AZ EN Rev. G Endura AZ oxygen monitor Superior technology and quality from the world leader in oxygen measurement Advanced design and precision manufacturing robust, long-life probe for process

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS LC pressure and temperature compensated flowmeter easy and cost effective installation of the senor no pressure loss caused by the sensor no moving parts, i.e.

More information

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES: Rosemount 1810 Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES: A cleanable and compact stainless steel design An innovative patented venting configuration that prevents gauge reference

More information

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been established over the last 80 years. The electromagnetic

More information

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation Product Data Sheet 3051S Series delivers highest field performance and reliability SuperModule Platform provides a foundation for integrated pressure, flow, and level solutions IEC 62591 (WirelessHART

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer

More information

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter The 10D1477 electrodeless ceramic lined wafer sensors and 50XM1000 transmitters are pulsed DC magnetic flowmeters. These

More information

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 Series Flowmeters Low Cost, Low Maintenance ir, Compressed ir and Nitrogen Flow Measurement for Process and Plant pplications Wastewater Treatment eration Control lower and Dryer ir Flow Control

More information

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7 Features User Accessible Memory for Test Configuration Management ±0.05% FS System Accuracy EU Throughput Rates of 500 Hz Auto-Negotiating 10/100 BaseT Ethernet with TCP & UDP Protocol Pressure Ranges

More information

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation Product Data Sheet January 2013 00813-0100-4801, Rev RA Rosemount 3051S Series of Instrumentation Scalable Pressure, Flow, and Level Solutions Innovation Reaching Across Your Operation With the Rosemount

More information

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER Design Specifications DS-9900 Revision 04 9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER 2-Wire loop powered flowmeter/transmitter 316 Stainless steel measuring unit Automatic temperature

More information

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters Product Data Sheet PS-001041, Rev. F February 2010 Micro Motion ELITE High Capacity Coriolis Flow and Density Meters Micro Motion ELITE High Capacity Coriolis meters offer unparalleled flow and density

More information

Micro Motion ELITE Mass Flow and Density Meters

Micro Motion ELITE Mass Flow and Density Meters Product Data Sheet PS 00374, Rev. A July 2003 Micro Motion ELITE Mass Flow and Density Meters Available with MVD Technology! TM Micro Motion Micro Motion ELITE mass flow and density meters Experience the

More information

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer Technical Offer Antek Model 6200 Analyzer 2015.4 Determine Total Sulfur and Total Nitrogen in a single analyzer Meet sulfur regulations and control your process with continuous sulfur and/or nitrogen measurements

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87 SMART VALVE POSITIONER to ma + HART Digital Communication B87 DESCRIPTION The FY microprocessor based positioner provides fast and accurate positioning of diaphragm or cylinder actuators. The FY produces

More information

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor! PRESSURE SENSORS PRESSURE PDP3 Series 0-2 32 PDP3 Series 0-10, 0-25 34 PG Gauge Series 36 PW Wet-Wet Series (Cable Version) 38 PW Wet-Wet Series (Conduit Version) 40 PW Series Ordering Guidance 42 Selectable

More information

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric. Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power

More information

Armstrong In-Line and Insertion Vortex Flow Meters

Armstrong In-Line and Insertion Vortex Flow Meters Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line

More information

Fan/Damper Actuators with Optional FoundationTM fieldbus Communications

Fan/Damper Actuators with Optional FoundationTM fieldbus Communications Fan/Damper Actuators with Optional FoundationTM fieldbus Communications Combines the power and reliability of the Hagan Pneumatic Drive with the accuracy and features of the Fisher DVC5000/6000 Digital

More information

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays

More information

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001 Micro Motion T-Series Straight-Tube Mass Flow and Density Meters Product Data Sheet PS-00371 July 2001 Micro Motion T-Series Straight-Tube Meters Micro Motion is proud to offer you the first single-straight-tube

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011 Product Data Sheet PDS 71-400/rev.J January 2011 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

Rosemount 3051S Electronic Remote Sensor (ERS) System

Rosemount 3051S Electronic Remote Sensor (ERS) System Rosemount 3051S Electronic Remote Sensor (ERS) System The Rosemount 3051S ERS System is a flexible, 2-wire 4-20 ma ART architecture that calculates differential pressure (DP) electronically using two pressure

More information

Rosemount 3051T In-Line Pressure Transmitter

Rosemount 3051T In-Line Pressure Transmitter Rosemount 3051T In-Line Pressure Transmitter Rosemount 3051T In-line Pressure Transmitters are the industry standard for Gage, and Absolute pressure measurement. The in-line, compact design allows the

More information

Masoneilan Series

Masoneilan Series Masoneilan 12300 Series Digital Level Transmitter & Controller Specification Data CU3000 02/02 Digital Level Measurement and Control Instrumentation Table of Contents General Description...2 Principle

More information

Micro Motion 7827 Digital Viscosity Meter

Micro Motion 7827 Digital Viscosity Meter Product Data Sheet PS-001217, Rev. C April 2013 Micro Motion 7827 Digital Viscosity Meter Micro Motion viscosity meters are built to tackle the most demanding process and control applications. Rugged and

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO.: C3500L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3500L 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,

More information

Now available with MVD Technology! ELITE Mass Flow and Density Meters

Now available with MVD Technology! ELITE Mass Flow and Density Meters Product Data Sheet PS-00374 July 2001 Now available with MVD Technology! ELITE Mass Flow and Density Meters Micro Motion ELITE Meters Experience the most accurate Coriolis meters available today. Micro

More information

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V TM Advantage: VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an

More information

Monocrystalline silicon smart differential pressure transmitter. High stability, Diaphragm sealed. Benefits. Application

Monocrystalline silicon smart differential pressure transmitter. High stability, Diaphragm sealed. Benefits. Application Monocrystalline silicon smart differential pressure transmitter DRS380 High stability, Diaphragm sealed Detailed Information www.dersensor.com Application the flow of gas, vapor and liquid measurement

More information

Technical Offer. ViscoPro Measure Viscosity and Temperature on line for continuous process improvement

Technical Offer. ViscoPro Measure Viscosity and Temperature on line for continuous process improvement Technical Offer ViscoPro 2100 2015.2 Measure Viscosity and Temperature on line for continuous process improvement Advantages: Long and stable calibration Vibration and flow rate insensitivity Low maintenance

More information

UTM10 Series Ultrasonic Transit-time Flowmeters

UTM10 Series Ultrasonic Transit-time Flowmeters Page 1 of 5 TI-P197-01 MI Issue 1 UTM10 Series Ultrasonic Transit-time Flowmeters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal

More information

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6 Data Sheet Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6 Wide Range of Torque Ratings - Six actuator sizes available in ratings from 122 to 6372 Newton meters (90 to 4700 foot-pounds)

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

Micro Motion F-Series Coriolis Flow and Density Meters

Micro Motion F-Series Coriolis Flow and Density Meters Product Data Sheet PS-00603, Rev. F December 2007 Micro Motion F-Series Coriolis Flow and Density Meters Micro Motion F-Series Coriolis meters offer highly accurate mass flow, volume flow, and density

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO.: C3100L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3100L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200

More information

Proximity Transmitters, and Seismic Vibration Transmitters

Proximity Transmitters, and Seismic Vibration Transmitters TM016 Velocity/ Acceleration Vibration Transmitter Introduction The TM016 is a solid state loop powered transmitter which provides a 4-20mA output proportional to the machine case vibration level. The

More information

TORRIX Magnetostrictive level sensor

TORRIX Magnetostrictive level sensor TORRIX Magnetostrictive level sensor Precision Versatility Security Sensors & Systems Worldwide: www.fafnir.com FAFNIR Quality and Satisfaction Company: Based in Hamburg, Germany, FAFNIR GmbH has over

More information

STEEMCO-MAS Flowmeter for Steam

STEEMCO-MAS Flowmeter for Steam STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical

More information

UNIVERSAL Flow Meters

UNIVERSAL Flow Meters MAX FLOW SIZES FROM 500 TO 1500 GPM (2000 TO 5600 LPM) MAX LIQUID PRESSURE 300 PSIG (20.69 BAR) XHF SERIES UNIVERSAL Flow Meters An Extra-Large Vane Style For Liquids NIST Traceable Calibration Certificate

More information

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1 DUST ALERT - 3000 BinMaster Price Book 01-2019 binmaster.com Subject to change without notice 1 DUST ALERT - 3000 Dust Alert - 3000 The Dust Alert with integrated electronics and sensing probe utilizes

More information

REVOLUTIONIZE YOUR DENSITY AND CONCENTRATION MEASUREMENT TECHNOLOGY

REVOLUTIONIZE YOUR DENSITY AND CONCENTRATION MEASUREMENT TECHNOLOGY REVOLUTIONIZE YOUR DENSITY AND CONCENTRATION MEASUREMENT TECHNOLOGY Micro Motion Fork Density Meter INTRODUCING EMERSON S MICRO MOTION FORK DENSITY METER Our Fork Density Meter (FDM) delivers accurate

More information

Dissolved Oxygen, ph, and Conductivity

Dissolved Oxygen, ph, and Conductivity Product Data Sheet PDS 71-steam/rev.E February 2005 Steam Sterilizable Solutions Dissolved Oxygen, ph, and Conductivity STEAM STERILIZABLE AND AUTOCLAVABLE DISSOLVED OXY- GEN, ph, AND CONDUCTIVITY SENSORS:

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

Ignition devices. Lighting up Innovation

Ignition devices. Lighting up Innovation Ignition devices Lighting up Innovation Proven leader in the industrial ignition industry, Tesi manufactures a unique range of high energy, high voltage and portable ignition systems assuring ignition

More information

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters Electronic Pressure Catalog > Hazardous Area > E-10, E-11 Type E-10, E-11 Hazardous Area Explosion-proof Transmitters Meets ANSI / ISA 12.27.01-2003 single seal requirements - no dual seal required Applications

More information

SATRON VTe pressure transmitter

SATRON VTe pressure transmitter SATRON VTe pressure transmitter belongs to the series V-transmitters which will have both analog and smart properties. SATRON VTe is used for 0-4 kpa...0-00 MPa ranges. The transmitter communicates in

More information

Rosemount DP Level Transmitters and 1199 Remote Seals

Rosemount DP Level Transmitters and 1199 Remote Seals Product Data Sheet FOR ROSEMOUNT 3051S, 3051, AND 2051 TRANSMITTERS APPLICATIONS Level, Flow, Pressure, Interface, Density Extreme hot and cold temperatures Corrosive, clogging, or viscous processes Hygienic

More information

General Purpose ph/orp Sensors

General Purpose ph/orp Sensors General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 September 2013 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided by double

More information

Range of Ultrasonic Flowmeters.

Range of Ultrasonic Flowmeters. Range of Ultrasonic Flowmeters www.adeptfluidyne.com Ultrasonic Flowmeter Series 6700 Working Principle The Transit Time Flowmeter utilises two transducers that function as both, ultrasonic transmitters

More information

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands Conductivity meter Configurable outputs: two transistor and single or dual analog 4... 20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.a June 1998

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.a June 1998 Product Data Sheet 71-140 series/rev.a June 1998 Model 140, 141, 142 Conductivity Sensors HIGH TEMPERATURE 316 SS AND PEEK CON- STRUCTION operates up to 200 C (392 F). MODEL 140 RETRACTABLE SENSOR installs

More information

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Product Data Sheet Rosemount 3051 Rosemount 3051 Pressure Transmitter THE PROVEN INDUSTRY LEADER IN PRESSURE MEASUREMENT Best-in-Class performance with up to 0.04% reference accuracy Industry first installed

More information

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability Series 60 New Smart Positioner Compact design Convenient & powerful function Enhanced reliability J Flow Controls, LLC 14 De Camp Cincinnati, OH 45216 Phone: 513-731-2900 Fax 513-731-6939 www.jflowcontrols.com

More information