Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Size: px
Start display at page:

Download "Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:"

Transcription

1 Section 6.1 Implement Circuit - General System General: TF Configuration TB Configurations Implement Pump Breakdown Operational Description: General Compensator Control Standby Condition On-Stroke Condition Pressure Compensation Implement Control Valve: Description LS90 Operation L90LS Valve Cross-Section K220 Valve Cross-Section Form T Implement Circuit - General

2 T0026 Figure 1: Simplified TF 830 Implement Circuit Diagram (Typical) Implement Circuit - General Form T011

3 General - TF Configurations (See Figure 1) The TimberPro TF 830 implement circuit is a closed center hydraulic system. The system uses state-of-the-art components such as a load sensing axial piston pump, radial piston motors, and pressure compensated (electriccontrolled-pilot operated) control valves. The main components in the system are: 1) 60 gal. (227 litre) hydraulic oil tank for storage and cooling of the hydraulic oil. See Section 3.2 in this manual for important information on the hydraulic tank and its components. 2) 100-mesh implement suction strainer w/ magnetic stem. 3) Suction line shut-off valve. 4) Rexroth AA11VO gpm (360 litres) variable displacement axial piston implement pump with pressure flow compensating capabilities. 5) VOAC 5-section main control valve with load sensing and flow compensation capabilities. All sections are electric-controlled-pilot operated. 6) Load sense orifice (.024). This orfice is located in the #6 connector turned into the PL port on the mid inlet section of the control valve. 7) High pressure, double acting cylinders and radial piston motors. 8) 14-port rotary manifold for 360 continuous rotation swing. In the implement circuit it provides the hydraulic link to the steer cylinders located in the rear frame. 9) Rexroth AA2FE series fixed displacement, bi-directional, piston motor mated to a Lohamnn GFB-72 planetary reduction gearbox with a wet mult-disc brake and anti-cavitation manifold. 10) 130 psi (1,03 Mpa) return line check valve. To create back pressure in the system to help with Anti-Cavatation on the Swing Motor. This check valve is located inside the end cap of the Voac control valve. 11) High capacity oil cooler with a F (49-60 C) thermal bypass and 50 psi (3,45 kpa) back pressure bypass. 12) Return and case drain filters in the hydraulic tank. See Section 3.2 in this manual for important information on the hydraulic tank and its components. 13) Fixed displacement, bi-directional, gear motors that turn the cooling fans for the engine radiator and hydraulic oil cooler. 14) Charge and Fan Drive Manifold. This manifold is supplied oil from the charge pump and controls the oil cooler fans, the radiator fan and also regulates and filters the charge oil being supplied to the wheel drive pump. 15) Charge pump. The charge pump is a 52cc gear pump that supplies oil to the wheel drive pump charge circuit and supplies oil for the radiator and cooler fans. 16) Lower Pressure Supply manifold provides high pressure from the implement pump to the lower manifold. 17) Lower Manifold is used to operate things like the brakes, gear box, motor shift, differential lock, frame lock and is also used to flush hot oil from the wheel drive motors. Form T Implement Circuit - General

4 T0027 Figure 2: Simplified TB 630 Implement Circuit Diagram Implement Circuit - General Form T011

5 General - TB Configurations (See Figure 1) The TimberPro TB 630 implement circuit is a closed center hydraulic system. The system uses state-of-the-art components such as a load sensing axial piston pump, radial piston motors, and pressure compensated (electriccontrolled-pilot operated) control valves. The main components in the system are: 1) 60 gal. (227 litre) hydraulic oil tank for storage and cooling of the hydraulic oil. See Section 3.2 in this manual for important information on the hydraulic tank and its components. 2) 100-mesh implement suction strainer w/ magnetic stem. 3) Suction line shut-off valve. 4) Rexroth AA11VO gpm (360 litres) variable displacement axial piston implement pump with pressure flow compensating capabilities. 5) VOAC main control valves with load sensing and flow compensation capabilities. All sections are electric-controlled-pilot operated. 6) Load sense orifice (.024). This orfice is located in the #6 connector turned into the PL port on the mid inlet section of the control valve. 7) High pressure, double acting cylinders and radial piston motors. 8) 14-port rotary manifold for 360 continuous rotation swing. In the implement circuit it provides the hydraulic link to the steer cylinders located in the rear frame. 9) Rexroth AA2FE series fixed displacement, bi-directional, piston motor mated to a Lohamnn GFB-72 planetary reduction gearbox with a wet mult-disc brake and anti-cavitation manifold. 10) 130 psi (1,03 Mpa) return line check valve. To create back pressure in the system to help with Anti-Cavatation on the Swing Motor. This check valve is located inside the end cap of the Voac control valve. 11) High capacity oil cooler with a F (49-60 C) thermal bypass and 50 psi (3,45 kpa) back pressure bypass. 12) Return and case drain filters in the hydraulic tank. See Section 3.2 in this manual for important information on the hydraulic tank and its components. 13) Fixed displacement, bi-directional, gear motors that turn the cooling fans for the engine radiator and hydraulic oil cooler. 14) Charge and Fan Drive Manifold. This manifold is supplied oil from the charge pump and controls the oil cooler fans, the radiator fan and also regulates and filters the charge oil being supplied to the wheel drive pump. 15) Charge pump piggy-back mounted to the implement pump. The charge pump is a 52cc gear pump that supplies oil to the wheel drive pump charge circuit and supplies oil for the radiator and cooler fans. 16) Lower Manifold Supply pump piggy-back mounted to the Charge pump. The Lower Manifold Supply pump is a 10cc gear pump and supplies oil that is used in the lower manifold. 17) Lower Manifold is used to operate things like the brakes, gear box, motor shift, differential lock, frame lock and is also used to flush hot oil from the wheel drive motors. Form T Implement Circuit - General

6 POR Pressure Adjustment Standby Pressure Adjustment Case Drain Suction Inlet Pump Compensator Rexroth AAV11O Series Pump P Pressure Manifold (Connection for P port pressure to control valve & optional clam bunk, and mono-block brake manifold) Figure 3: Implement Pump Breakdown Implement Circuit - General Form T011

7 Load Sense From Valve Standby Pressure Adjust (Load Sensing) Maximum Pressure Limiting (POR) Figure 4: Pump Compensator Control Operational Description General The implement hydraulic system uses a Rexroth AA11VO series hydraulic pump. This is a variable displacement piston pump with a load sensing, pressure limiting compensator control. Compensator Control (See Figure 4) The compensator control has three main oil galleries that connect to the pump at its mounting base. The first gallery (Ref #1) vents to tank via the pump case. The second gallery (Ref #2) connects to the pump s large control piston. The third gallery (Ref #3) is the P pressure connection. P pressure is the pressure seen at the outlet of the pump and at the pumps small control piston (bias stem). Each spool has a mechanical spring force applied at one end (Ref #6). The amount of spring force can be changed by turning an adjustment setscrew (Ref #7) IN or OUT to preload the spring. Turning the adjustment screw IN increases spring preload, requiring more force at the opposite end of the spool to overcome the spring. Turning the adjustment screw OUT decreases spring preload, requiring less force at the opposite end of the spool to overcome the spring. Both spools are open on the opposite end to P pressure. P pressure provides the hydraulic force used to overcome the mechanical spring force. Inside the compensator control are two spools; stand-by (Ref #4), and pressure limiting, (Ref #5). Form T Implement Circuit - General

8 Standby Condition When all functions are in neutral, oil flow to the main control valve port P is blocked. In this pump standby condition P pressure on one side of the standby (load sensing) spool overcomes the mechanical spring force on the other side of the spool. This forces the spool to shift thus allowing P pressure past the spool to the large control piston. The pressure on the large control piston forces it to shift, overcoming the small control piston (bias stem) and moving the swash plate to the de-stroke position. By adjusting the spring tension exerted against the standby spool, the standby pressure will be increased or decreased. Standby pressure is the minimum pressure required to maintain control of the pump. TF820 standby pressure is set at 400 PSI (2,75 Mpa) Figure 5: Implement Pump Compensator Control - Standby Condition Implement Circuit - General Form T011

9 On-Stroke Condition The main control valve and implement pump are tied together with a load sense signal line. When a function is activated the control valve induces a load sense signal to the spring side of the standby (load sensing) spool. The load sense pressure adds to the existing spring force which in turn overcomes P pressure on the other side of the spool. This forces the standby spool to shift thus venting the large control piston to the hydraulic tank through the pump case drain. With the large control piston vented to tank, P pressure on the small control piston (bias stem) moves the swash plate to it s on-stroke position. The strength of the load sense signal from the control valve determines how much pressure will be required to do the work Figure 6: Implement Pump Compensator Control - On-Stroke Condition Form T Implement Circuit - General

10 Pressure Compensation To limit maximum implement system pressure the pump uses an adjustable pressure compensator (also called pressure limiting or pressure override<por>). POR pressure is set at 3000 PSI (20,6 Mpa), for the TF and TS configurations, or 3800 PSI (26,2 Mpa) for the TB configuration. Pressure compensation is done at the pump compensator with a pressure limiting (POR) spool. On one side of the pressure limiting spool is adjustable spring force. On the other side of the spool is P pressure. When P pressure overcomes the spring force the spool shifts, routing P pressure past the spool to the large control piston. This pressure on the large control piston forces it to shift, overcoming the small control piston (bias stem) and moving the swash plate to the minimum displacement position. The pump in this position would produce only enough flow to maintain the maximum system pressure Figure 7: Implement Pump Compensator Control - Pressure Compensation Implement Circuit - General Form T011

11 Implement Control Valve Description The Timberpro T800 utilizes a VOAC L90LS or K220 series directional control valve. The valve is a stackable proportional, load sensing and flow compensated, closed center valve. The valve is controlled with proportional, electric-over-hydraulic controls. L90LS Operation NOTE: Operation of the K220 valve used on the TB configuration is very similar in operation to the L90LS valve used on the TF and TB configurations. By breaking the VOAC valve down into its three major components (Mid inlet section, end section, and spool section) it will be easier to understand. Inlet Section The inlet section is where the pump connections are made. These connections are the load sense line and pump pressure line and tank. A direct acting main safety relief is also incorporated into the inlet section to protect the valve and pump from pressure spikes. This relief is a cartridge style relief that is factory preset at 4350 PSI (300 bar) and is not adjustable. End Section Internal pilot pressure supply is a valve function built into the end section. The end section is fitted with a non-adjustable pilot pressure reducing valve factory preset at 320 PSI (22 bar). This gives an internal pilot supply for the electro-hydraulic pilot caps to shift the main valve spools. For safety reasons, the pilot pressure reducing valve is equipped with a separate non-adjustable safety relief factory preset at 500 PSI (35 bar). Also incorporated into the end section is a pilot oil filter equipped with a bypass. The filter protects internal pilot circuit from contamination. Four ports are used in the end section. 1) T2B - Return oil to tank. 2) T3B - Oil supply for the frame lock circuit 3) LSP - Load sense drain 4) P2 - Auxiliary pressure port that supplies the mono-block valve Spool Section (See Figure 8) The spool section consists of a body, 4-way main spool, compensator spool, port relief valves, and electric proportional solenoids. The electric proportional solenoids (Ref #6 & #7) are controlled by a proportional current signal from the IQAN digital control system. As the current to the solenoids changes, the valve produces a pilot signal proportional to the current supplied. This changing pilot pressure pushes the 4-way main spool (Ref #2) in either the A or B direction. Not only is direction determined, but also how far the spool travels. Primary load sense is connected through the timed drillings in the main spool (Ref #4). When the main spool shifts the load sense will communicate with the work ports. The load sense signal travels to the pump control through the section shuttle valve (not shown). These shuttles are hardened seats located between each section. The series of shuttles allow only the load sense signal from the section with the highest pressure to reach the pump. The load sense signal also travels into the spring chamber (Ref #9) of the section compensator spool (Ref #10). The compensator spool spring and the section s load sense pressure maintain a constant pressure across the main spool. Having a constant pressure drop across the main spool allows the section to deliver oil flow that is proportional to the main spool position. Port reliefs (Ref #3 & #5) are also used on all sections. The port reliefs on standard machines are set at 4060PSI (280 bar). All port reliefs have an anti-cavitation feature. The system tank line has a 130 PSI (9 bar) back pressure check valve. The back pressure check valve causes the oil flow through the anti-cavitation checks to maintain back pressure on all components. Form T Implement Circuit - General

12 1) Spool Stop 2) 4-Way Main Spool 3) A Port Relief 4) Load Sense Communication Hole 5) B Port Relief 6) A Solenoid Coil 7) B Solenoid Coil 8) LS Dampening Orifice 9) Compensator Spring 10) Compensator Spool 11) Centering Spring 12) Cover 13) Proportional Solenoid Orifice Figure 8: Implement Control Valve Spool Section Cut-Away - LS90 Implement Circuit - General Form T011

13 1) Spool Stop 2) Main Work Spool 3) A Port Relief 4) Load Sense Communication Hole 5) B Port Relief 6) A Solenoid Coil 7) B Solenoid Coil 8) Proportional Solenoid Orifice 9) Compensator Spool 10) Cover T0837 Figure 9: Implement Control Valve Spool Section Cut-Away - K220 Form T Implement Circuit - General

14 Implement Circuit - General Form T011

15 Section 6.2 Implement Circuit - Tests & Adjustments Safety Information Tools Required Implement Pump Stand-by Pressure Implement Pump POR Pressure Implement Pump Case Pressure Implement Pump Case Flow Swing Charge Pressure Swing Pump POR Pressure Swing Pump Null Disc Saw Pump Stand-by Disc Saw Pump POR Form T Implement Circuit - Tests & Adjustments

16 Safety information You must read and understand the warnings and basic safety rules, found in Group-1 of the Operation & Maintenance manual, before performing any operation, test or adjustment procedures. Tools Required Tachometer 0-60 psi ( kpa) pressure gauge psi (0-5 Mpa) pressure gauge 0-10,000 psi (0-80 Mpa) pressure gauge 9/16, 11/16, 3/4, 13/16, 1-1/4, & 1-3/8 wrenches 13mm wrench 4mm allen wrench PN# 15437, #12 ORS cap PN# 15869, quick-couple adapter PN# 18838, #6 ORS plug PN# 18839, #6 ORS cap Gauge test hose #12 ORBM - #4 JICM adapter Calibrated container - 10 gallons (38 litres) Stop watch The operator or another mechanic may be required to operate a control while a pressure reading is being taken Diesel exhaust fumes contain elements that are hazardous to your health. Always run engine in a well ventilated area. If in an enclosed space, vent exhaust to the outside. NOTE: Each machine is shipped from the factory with at least one 600 psi and one 10,000 psi gauge with quick-couple adapters. The gauges can be found in the machine Up-Time Kit At operating temperature, the engine, exhaust system components, cooling system components and hydraulic system components are HOT. Any contact can cause severe burns. Implement Circuit - Tests & Adjustments Form T012

17 Implement Pump Stand-By Pressure Specification: psi (28 bar) Test Standards: Hydraulics at operating temperature of 140 F (60 C) or greater. Engine operating at idle Procedure: 1. Ensure the hydraulics are at correct operating temperature. Figure 1: Disconnect Load Sense Line (Typical) Open the rear gullwing guard to access the swing pump. 3. Use the 13/16 wrench to disconnect the implement pump s load sense line were it connects to the load sense shuttle valve. See Figure 1. NOTE: The load sense must be disconnected before testing or adjusting the implement pump stand-by pressure. This prevents false readings from the control valve interacting with the pump. 3. Plug the Hose, but leave the pump open to atmosphere. 4. Start the engine and run at idle. 5. Connect the 600 psi pressure gauge, with the quick-couple adapter attached, to the gauge port tap provided on the centralized pressure check manifold. See Figure 2. NOTE: Only install a 600 psi pressure gauge after the engine is running. If the gauge is installed before the engine is started it can be damaged. 6. Read the pressure gauge, the implement pump stand-by pressure should be set at psi (28 bar). If implement pump stand-by pressure setting is correct, go to step #11. If adjustment is required, continue with step #7. 7. Use the 13mm wrench to loosen the jam nut on the stand-by pressure adjustment setscrew. See Figure Use the 4mm allen wrench to turn the adjustment setscrew. T0026 Figure 2: Implement Pump Pressure Gauge Port Tap Turning the adjustment setscrew CLOCKWISE increases the pressure setting. Turning the setscrew COUNTER-CLOCKWISE decreases the pressure setting. Form T Implement Circuit - Tests & Adjustments

18 00676 Stand-By Pressure Figure 3: Implement Pump Stand-By Pressure Adjustment 9. Read the pressure gauge and adjust pressure setting as required. 10. After the correct pressure setting is made, tighten the jam nut to lock the setscrew. 11. Remove the pressure gauge and shut down the engine. 12. Re-connect the load sense line removed in step #3. NOTE: It is not necessary to bleed the load sense line because the pump is vented internally. 13. Close and secure the rear engine guard. Implement Circuit - Tests & Adjustments Form T012

19 Implement Pump POR Pressure Specification: /- 50 psi (262 +/- 3.5 bar) NOTE: The settings listed above are standard settings for most TimberPro machines. Some specialized machines with special attachments can require these settings to be different. Please contact your TimberPro dealer if you have any question on the setting of your machine. Test Standards: Hydraulics at operating temperature of 140 F (60 C) or greater. Engine operating at high idle (approx RPM). Procedure: 1. Ensure the hydraulics are at correct operating temperature. 2. Open the rear gullwing guard to access the swing pump. 3. Connect the 10,000 psi pressure gauge, with the quick-couple adapter attached, to the gauge port tap provided on the centralized pressure check manifold. See Figure Start engine and increase engine throttle to high idle (approx RPM). 5. Instruct the operator or another mechanic to bottom out an implement function while you read the pressure gauge, implement pump POR pressure should be set at specification. (Because different function have different pressure settings make sure and select a function (stick boom) that has a main relief setting higher than the implement pump POR.) See Figure Use the 4 mm allen wrench to turn the adjustment setscrew. Turning the adjustment setscrew CLOCKWISE increases the pressure setting. Turning the setscrew COUNTER-CLOCKWISE decreases the pressure setting. 9. Instruct the operator or another mechanic to bottom out an implement function while you read the pressure gauge, implement pump POR pressure should be set at specification. (Because different function have different pressure settings make sure and select a function (stick boom) that has a main relief setting higher than the implement pump POR.) 10. After the correct pressure setting is made, tighten the jam nut to lock the setscrew. 11. Shut down the engine. POR Pressure Figure 5: Implement Pump POR Pressure Adjustment 12. Remove the pressure gauge then close and secure all access panels and guards. 6. If implement pump POR pressure setting is correct, go to step #10. If adjustment is required, continue with step #7. 7. Use the 13 mm wrench to loosen the jam nut on the POR pressure adjustment setscrew. Form T Implement Circuit - Tests & Adjustments

20 Implement Pump Case Drain Pressure Specification: Maximum 35 psig (2.4 bar) allowed. Test Standards: Hydraulics at operating temperature of 140 F (60 C) or greater. Engine operating at full throttle (approx RPM). Implement pump pressure at specification. Procedure: 1. Produce a gauge test hose that will allow you to tee in a 60 psi (4 bar) gauge to the #12 ORFS connector that will be installed into the implement pump case drain port. 2. Ensure the hydraulics are at correct operating temperature. 3. Open the rear gullwing guard to access the swing pump. Be sure the pump case is full of oil before starting the machine otherwise catastrophic damage to the pump will occur. 6. Start engine and run at full throttle. 7. Instruct the operator or another mechanic to bottom out an implement function and hold it for a full minute while you observe the pressure gauge. The implement pump case drain pressure should not exceed specification. If the specification is exceeded, look for conditions that would increase backpressure in the case drain circuit such as a plugged case drain filter element, failing component, etc. 8. After completing the test, cycle all implement functions for a least 2-minutes to cool the hydraulics down. 9. Shutdown the engine and remove the adapter tee that was installed for testing. 10. Close and secure the rear engine guard. 4. Locate and remove the implement pump case drain hose and connector and tee in a fitting and 60 psi (4 bar) gauge. 5. Install the gauge test hose and pressure gauge to the case drain port adapter. Implement Circuit - Tests & Adjustments Form T012

21 Implement Pump Case Drain Flow Specification: New or rebuilt - Maximum 4.6 gpm (17,5 litres) allowed. Used - Maximum 5.8 gpm (22 litres) allowed. Test Standards: Hydraulics at operating temperature of 140 F (60 C) or greater. Engine operating at full throttle (approx 2000 RPM). Implement pump pressure at specification. Procedure: 1. Ensure the hydraulics are at correct operating temperature. 2. Open the rear gullwing guard to access the swing pump. Be sure the pump case is full of oil before starting the machine otherwise catastrophic damage to the pump will occur. 5. Start engine and run at full throttle. Immediately have the operator or another mechanic bottom out an implement function and hold it for a full minute. 6. After one minute, deactivate the implement function and shutdown the engine. 7. Remove implement pump case drain hose from the container and re-connect it to the hydraulic tank. 8. Cycle all implement functions for a least 2-minutes to cool the hydraulics down. 9. Measure the oil in the container. If the amount exceeds specification, the implement pump is worn or failing and may have to be replaced. 10. Close and secure the rear engine guard. 3. Use the 1-1/4 and 1-3/8 wrenches to remove the implement pump case drain line at the hydraulic tank. Cap the fitting to prevent contaminates from entering the hydraulic system. 4. Place the open end of the case drain hose into the calibrated container. Form T Implement Circuit - Tests & Adjustments

22 Swing Drive Charge Pressure Specification: DO NOT set charge pressure above 450 psig (31 bar). Overheating of the circuit and damage to the system can result. 425 psig (29.3 bar) Test Standards: Hydraulics at operating temperature of 140 F (60 C) or greater. T00026 Figure 6: Swing Drive Charge Pressure Gauge Port Tap Engine operating at high idle (approx RPM). Procedure: 1. Ensure the hydraulics are at correct operating temperature. 2. Start the engine and run at low idle. 3. Connect the 600 psi pressure gauge, with the quick-couple adapter attached, to the gauge port tap provided on the centralized pressure check manifold. See Figure 6. NOTE: Only install a 600 psi pressure gauge after the engine is running. If the gauge is installed before the engine is started it can be damaged. 6. Increase engine throttle to high idle (approx RPM). 7. Read the pressure gauge, the Swing Drive charge pressure should be set at 425 psig (29.3 bar). If Swing Drive charge pressure setting is correct, go to step #10. If adjustment is required, continue with step #8. T00026 Figure 7: Swing Drive Charge Pressure Manifold 9. Locate the large charge pressure relief cartridge. See Figure 2. Use the 9/16 wrench and 5/32 allen wrench to loosen the jam nut. Turning the adjustment setscrew CLOCKWISE increases the pressure setting. Turning the setscrew COUNTER-CLOCKWISE decreases the pressure setting. 10. Read the pressure gauge, re-adjust pressure setting as required. After the correct pressure setting is made, tighten the jam nut to lock adjustment setting. 11. Shut down the engine. Remove the pressure gauge and secure the rear engine guard. 8. Open the rear engine guard and locate the Charge pressure manifold assembly. See Figure 7. Implement Circuit - Tests & Adjustments Form T012

23 Swing Pump POR Pressure Specification: 3350 psig (230 bar) Test Standards: Hydraulics at operating temperature of 140 F (60 C) or greater. Engine at high idle (approx RPM). Swing Pump charge pressure and charge spike relief set to specification. Procedure: Figure 8: Swing Pump Pressure Gauge Port Tap Operating the Swing Drives over relief produces extreme heat that can damage hydraulic system components. Expedite all pressure readings and adjustments. 1. Ensure the hydraulics are at correct operating temperature. 2. Position the boom close to the machine and chain the boom to the frame of the machine to stop the machine from swinging. Make sure to use a chain heavy enough to safely stop the machine from swinging. 6. Locate the POR relief on the Swing Pump. See Figure 9. Use the 13mm wrench and 4mm allen wrench to loosen the jam nut on the POR relief adjustment setscrew. 7. On your signal, have the operator or another mechanic apply the swing function while you set the POR relief to 3350 psig (230 bar). Turning the adjustment setscrew CLOCKWISE increases the pressure setting. Turning the setscrew COUNTER-CLOCKWISE decreases the pressure setting. 3. Connect the 10,000 psi pressure gauge, with the quick-couple adapter attached, to the gauge port tap provided on the centralized pressure check manifold. See Figure Instruct the operator or another mechanic to start the engine and run at high idle (approx RPM). 5. On your signal, have the operator or another mechanic apply the swing function while you set the POR relief to 3350 psig (230 bar). If Swing Pump POR pressure is correct, go to step #11. If an adjustment is required, continue with step #7. Figure 9: Swing Drive POR Relief Form T Implement Circuit - Tests & Adjustments

24 8. After the correct pressure setting is made, hold the adjustment setscrew stationary and tighten the jamnut to hold the pressure setting. 9. Shut down the engine and remove the pressure gauge. 10. Shut down the engine. Swing Pump Null Specification: Obtain the lowest possible pressure between ports X1 and X2 with the jumper hose installed. Test Standards: Hydraulics at operating temperature of 140 F (60 C) or greater. Engine operating at idle Procedure: 1. Ensure the hydraulics are at correct operating temperature. 2. Position the boom close to the machine and chain the boom to the frame of the machine to stop the machine from swinging. Make sure to use a chain heavy enough to safely stop the machine from swinging. 3. Open the rear gullwing guard to access the swing pump. 4. Using the 3/16 allen wrench, remove the plugs from ports X1 and X2. See Figure 11. Install the #6 ORBM adapters into the ports. 5. Connect the 24 (61cm) jumper hose between ports X1 and X2. 6. Start the engine and run at idle. The engine will remain running throughout the procedure. 7. Connect the 10,000 psi pressure gauge, with the quick-couple adapter attached, to the gauge port tap on the Swing Pump. See Figure The mechanical null adjustment is made with a large setscrew in the control piston cover. See Figure 13. Use the 24mm wrench and 8mm allen wrench, to loosen the jamnut and turn the adjustment setscrew in and out until the gauge reads the lowest possible pressure. NOTE: The lowest pressure reading indicates when the control piston is in the centered null position. 9. Remove the 10,000 psi gauge and install the 600 psi gauge in its place. Repeat step #8 to make the final adjustment. 10. Remove the 600 psi gauge and install the 10,000 psi gauge in its place Figure 10: Swing Pump Pressure Gauge Port Tap The hydraulic null adjustment is made with an eccentric pin and should not be turned more than 90 from center (as indicated by a notch on the adjustment screw), otherwise damage to the eccentric pin could result. 11. The hydraulic null adjustment is made with a small setscrew on top of the stroke control. See Figure 11. Use the 13 mm wrench and 4 mm allen wrench, to loosen the jam nut and turn the adjustment setscrew in and out until the gauge reads the lowest possible pressure. NOTE: The lowest pressure reading indicates when the control spool is in the centered null position. 12. Remove the 10,000 psi gauge and install the Implement Circuit - Tests & Adjustments Form T012

25 Port X2 Port X1 Hydraulic Null Adjustment Setscrew Mechanical Null Adjustment Setscrew Figure 11: Hydrostatic Pump Null Adjustments 600 psi gauge in its place. Repeat step #11 to make the final adjustment. 13. Shut-down engine and remove jumper hose, fittings, and gauge. 14. Procedure complete. Form T Implement Circuit - Tests & Adjustments

26 Disc Saw Pump Stand-By Pressure Specification: psig ( bar) Test Standards: Hydraulics at operating temperature of 140 F (60 C) or greater. Engine operating at idle Tools Required: 17 mm wrench 3/16 Allen wrench 3 mm Allen wrench psi ( bar) pressure gauge Procedure: 1. Be sure the disc saw circuit switch on the right Joystick Pod is in the OFF position so that the disc saw blade does not start during the procedure. See Figure Open the rear gullwing guard to access the disc saw pump. 3. Install the gauge at the disc saw pump pressure output block See Figure Start the engine and run at low idle. Figure 12: Disc Saw Circuit ON and OFF Switch If the disc saw stand-by pressure setting is correct, go to step #12. If adjustment is required, continue with step #9. 9. Locate the stand-by pressure adjustment setscrew on the disc saw pump compensator. See Figure Use the 17 mm wrench to remove the protective acorn nut. Use the 3 mm Allen wrench to hold the adjustment setscrew stationary while loosening the jamnut with the 17 mm wrench. 11. Turn the adjustment setscrew out COUNTERCLOCKWISE until the gauge reads about 100 psig (690 kpa), then in CLOCKWISE until the gauge reads the correct pressure of psig ( bar). Gauge Port T Ensure the hydraulics are at correct operating temperature. 6. Connect the 600 PSI pressure gauge to the gauge test hose. 7. Increase engine throttle to 1500 RPM. 8. Read the pressure gauge. The disc saw stand-by pressure should be set at psig ( bar). Stand-By Pressure Figure 13: Stand-by Pressure Gauge Installation (Typical) Implement Circuit - Tests & Adjustments Form T012

27 Tighten the jamnut to lock in the adjustment. See Figure 13. Gauge Port 12. Shut-down the engine and remove the gauge test hose and pressure gauge. 13. Close and secure the rear gullwing guard. 14. Procedure complete. Disc Saw Pump POR Pressure Tools Required: 17 mm wrench 3 mm Allen wrench Specification: 3950 psig (272 bar) Test Standards: Hydraulics at operating temperature of 140 F (60 C) or greater. Engine operating at RPM. POR Pressure 2. Open the rear gullwing guard to access the disc saw pump. 3. Start the engine and run at low idle. 4. Ensure the hydraulics are at correct operating temperature Figure 15: POR Pressure Gauge Installation (Typical) 5. In order to get an accurate compensator pressure reading, the cutting disc must be pinned to prevent rotation. See the disc saw attachment manual for this procedure. 6. Increase engine speed to full throttle. Procedure: 1. Be sure the disc saw circuit switch on the right Joystick Pod is in the OFF position so that the disc saw blade does not start during the procedure. See Figure 14. Flying objects and moving parts can cause serious personal injury or death. Keep clear of disc saw cutting attachment when in operation. 7. Turn the disc saw circuit ON to signal the disc saw to come on-stroke. See Figure Read the pressure gauge mounted in the cab on the front left dash panel. See Figure 7. The disc saw POR pressure should be set at 3800 psig (262 bar). If the disc saw POR pressure setting is correct, go to step #12. If adjustment is required, continue with step #9. Form T012 T00051 Figure 14: Disc Saw Circuit ON and OFF Switch Locate the compensator pressure adjustment setscrew on the disc saw pump Implement Circuit - Tests & Adjustments

28 compensator. See Figure Use the 17 mm wrench to remove the protective acorn nut. Use the 3 mm Allen wrench to hold the adjustment setscrew stationary while loosening the jamnut with the 17 mm wrench. 11. Turn the adjustment setscrew out COUNTERCLOCKWISE until the gauge reads about 3200 psig (220.6 bar), then in CLOCKWISE until the gauge reads the correct pressure of 3950 psig (272 bar). Tighten the jamnut to lock in the adjustment. See Figure Shut-down the engine. 13. Close and secure the swing-out pump access guard. 14. Procedure complete. Implement Circuit - Tests & Adjustments Form T012

Section 6.1. Implement Circuit - General System. General: Implement Control Valve:

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Section 6.1 Implement Circuit - General System General: Implement Circuit... 6.1.3 Implement Pump Breakdown... 6.1.4 Operational Description: General... 6.1.5 Compensator Control... 6.1.6 Standby Condition...

More information

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Implement Circuit

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Implement Circuit Section 6.1 Implement Circuit - General System General: Implement Circuit... 6.1.3 Implement Pump Breakdown... 6.1.4 Operational Description: General... 6.1.5 Compensator Control... 6.1.6 Standby Condition...

More information

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve: Section 6.1 Implement Circuit - General System General: TF Configuration... 6.1.3 TB Configurations... 6.1.5 Implement Pump Breakdown... 6.1.6 Operational Description: General... 6.1.7 Compensator Control...

More information

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve: Section 6.1 Implement Circuit - General System General: TF Configuration... 6.1.3 TB Configurations... 6.1.5 Implement Pump Breakdown... 6.1.6 Operational Description: General... 6.1.7 Compensator Control...

More information

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel Section 7.1 Track Drive Circuit - General System Simplified Travel Circuit Diagrams: Neutral Controls... 7.1.2 Forward Travel... 7.1.4 Reverse Travel... 7.1.5 General... 7.1.3 Track Drive Circuit: General...

More information

Section 7.1. Wheel Drive Circuit - General System

Section 7.1. Wheel Drive Circuit - General System Section 7.1 Wheel Drive Circuit - General System Simplified Travel Circuit Diagrams: Neutral Controls... 7.1.2 Forward Travel... 7.1.4 Reverse Travel... 7.1.5 General... 7.1.3 Wheel Drive Circuit: General...

More information

Tests & Adjustments - General Machine. General Safety Hydraulic Tank Turbo Boost Regulator

Tests & Adjustments - General Machine. General Safety Hydraulic Tank Turbo Boost Regulator Section 8.1 Tests & Adjustments - General Machine General Safety......................................... 8.1.2 Hydraulic Tank Turbo Boost Regulator........................ 8.1.2 Hydraulic Tank Safety

More information

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM, Testing And Adjusting Introduction NOTE: For Specifications with illustrations, make reference to SPECIFICATIONS for 225 EXCAVATOR HYDRAULIC SYSTEM, Form No. SENR7734. If the Specifications are not the

More information

Table Of Contents B & 735B

Table Of Contents B & 735B Table Of Contents Last Updated - 10/08 Table Of Contents... 725B & 735B SECTION DESCRIPTION PAGE UP Upper Turntable Components A.2 EE Electronic (Cummins) Engine A.3 OC Operator Cab Components A.3 ES Electrical

More information

Pilot Oil Supply Circuit

Pilot Oil Supply Circuit Pilot Oil Supply Circuit Introduction Pilot system oil output from pilot pump (42) has the following three main functions: 1. To control main pump output. 2. To provide easier operation of control levers.

More information

Hydrostatic Drive. 1. Main Pump. Hydrostatic Drive

Hydrostatic Drive. 1. Main Pump. Hydrostatic Drive Hydrostatic Drive The Hydrostatic drive is used to drive a hydraulic motor at variable speed. A bi-directional, variable displacement pump controls the direction and speed of the hydraulic motor. This

More information

Section 35 Chapter 2 HYDRAULIC SYSTEM HOW IT WORKS AND TROUBLESHOOTING NH

Section 35 Chapter 2 HYDRAULIC SYSTEM HOW IT WORKS AND TROUBLESHOOTING NH Section 35 Chapter HYDRAULIC SYSTEM HOW IT WORKS AND TROUBLESHOOTING 6-80NH TABLE OF CONTENTS GENERAL INTRODUCTION... 35-3 Hydraulic Pumps... 35-3 Standard Flow PFC Pump Layout... 35-5 MegaFlow PFC Pump

More information

Hydrostatic System - Test and Adjust

Hydrostatic System - Test and Adjust Testing and Adjusting 236B, 246B, 252B and 262B Skid Steer Loaders Hydraulic System Media Number -RENR4867-03 Publication Date -01/11/2009 Date Updated -24/11/2009 Hydrostatic System - Test and Adjust

More information

Introduction. General Information. Systems Operation

Introduction. General Information. Systems Operation Systems Operation Introduction Reference: For illustrated Specifications, refer to the Specifications For 416, 426, 428, 436, 438, & Series II Backhoe Loaders Transmission, Form No. SENR3131. If the specifications

More information

Lesson 5: Directional Control Valves

Lesson 5: Directional Control Valves : Directional Control Valves Basic Hydraulic Systems Hydraulic Fluids Hydraulic Tank Hydraulic Pumps and Motors Pressure Control Valves Directional Control Valves Flow Control Valves Cylinders : Directional

More information

Hydrostatic Power Train

Hydrostatic Power Train Chapter Hydrostatic Power Train Specifications................................................................. -3 Test Specifications........................................................ -3 Repair

More information

Torque Converter, Transmission Pump, Screen And Filter

Torque Converter, Transmission Pump, Screen And Filter Page 13 of 27 Transmission Hydraulic System In Forward (Engine Running - Type 2 & 3 Control Valve Shown) (4) Transmission control valve. (5) Neutralizer valve. (6) Neutralizer solenoid. (7) Flow control

More information

LogSplitterPlans.Com

LogSplitterPlans.Com Hydraulic Pump Basics LogSplitterPlans.Com Hydraulic Pump Purpose : Provide the Flow needed to transmit power from a prime mover to a hydraulic actuator. Hydraulic Pump Basics Types of Hydraulic Pumps

More information

CENTAC Inlet and Bypass Valve Positioners

CENTAC Inlet and Bypass Valve Positioners CENTAC Inlet and Bypass Valve Positioners INGERSOLL-RAND AIR COMPRESSORS INLET AND BYPASS VALVE POSITIONERS Copyright Notice Copyright 1992, 1999 Ingersoll-Rand Company THIS CONTENTS OF THIS MANUAL ARE

More information

MP18/SIC & SIO Stacking Valve System Technical Information Manual

MP18/SIC & SIO Stacking Valve System Technical Information Manual Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service MP18/SIC & SIO Stacking Valve System Technical Information Manual The Drive & Control Company Copyright

More information

Section 4.2. Machine Operation - Operator s Machine Controls. Engine Throttle Control Hydraulic Motor Shift Switch (630)

Section 4.2. Machine Operation - Operator s Machine Controls. Engine Throttle Control Hydraulic Motor Shift Switch (630) Section 4.2 Machine Operation - Operator s Machine Controls Engine Throttle Control... 4.2.2 System Arm Switch... 4.2.2 Charge Heater Switch... 4.2.3 Parking Brake Switch... 4.2.3 Max Throttle Switch...

More information

Troubleshooting, Service Tips, And Major Improvements For Hydrostatic Transmissions (Special Edition){3200}

Troubleshooting, Service Tips, And Major Improvements For Hydrostatic Transmissions (Special Edition){3200} Page 1 of 75 Troubleshooting, Service Tips, And Major Improvements For Hydrostatic Transmissions (Special Edition){3200} 943, 953, 963, 973 Loaders Introduction The hydrostatic transmissions used in 943,

More information

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring. Test 1 1. Which statement is True? A. Pneumatic systems are more suitable than hydraulic systems to drive powerful machines. B. Mechanical systems transfer energy for longer distances than hydraulic systems.

More information

Section 3.2. Machine Maintenance - Hydraulic Oil and Tank Information

Section 3.2. Machine Maintenance - Hydraulic Oil and Tank Information Section 3.2 Machine Maintenance - Hydraulic Oil and Tank Information Hydraulic Oil Tank: Hydraulic Tank Oil Level... 3.2.2 Sight Gauge... 3.2.2 Warning Lights... 3.2.2 Hydraulic Oil Tank Pressurizing System...

More information

Implement and Steering/Hydraulic System Testing and Adjusting

Implement and Steering/Hydraulic System Testing and Adjusting Page 1 of 64 Testing And Adjusting Introduction Reference: This supplement contains the Specifications, Systems Operation, and Testing And Adjusting for the components and systems that are different than

More information

MP18 Stacking Valve System Technical Information Manual

MP18 Stacking Valve System Technical Information Manual Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service MP18 Stacking Valve System Technical Information Manual The Drive & Control Company Copyright 1996 Bosch

More information

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls. Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls. Standard Check Valve The standard check valve permits free flow in one direction

More information

GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc

GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc Hydraulic Consulting, Inc This special promotional CD is to demonstrate how your hydraulic troubleshooting manual can be ordered as an Adobe Acrobat ebook. It can be installed on any computer with the

More information

COOLING SYSTEM - V8. Cooling system component layout DESCRIPTION AND OPERATION

COOLING SYSTEM - V8. Cooling system component layout DESCRIPTION AND OPERATION Cooling system component layout 26-2-2 DESCRIPTION AND OPERATION 1 Heater matrix 2 Heater return hose 3 Heater inlet hose 4 Heater inlet pipe 5 Throttle housing 6 Connecting hose 7 Throttle housing inlet

More information

Machine Operation - General Safety and Operation Info. Operating Instructions Notice (Decal)

Machine Operation - General Safety and Operation Info. Operating Instructions Notice (Decal) Section 4.1 Machine Operation - General Safety and Operation Info Operating Instructions Notice (Decal)......................... 4.1.2 IMPORTANT Operating Instructions For TimberPro Machines (Decal)................................

More information

Section FF C Front Frame - Frame / Covers / Steps

Section FF C Front Frame - Frame / Covers / Steps Section FF-1 830800C & 840 Front Front Frame - - Frame Frame / Covers / Covers / Brackets / Steps / Steps 830C Front Frame - Frame / Covers / Steps Last Updated - 05/16 Front Frame - Frame / Covers / Steps

More information

Open Center Compact Valve Custom Installation Guide Rev A

Open Center Compact Valve Custom Installation Guide Rev A 200-0762-01 Open Center Compact Valve Custom Installation Guide 602-0575-01 Rev A 2014-12 Overview This guide provides information for completing a custom AutoSteer valve installation on wheeled farm vehicles

More information

Troubleshooting the Transmission Hydraulic System

Troubleshooting the Transmission Hydraulic System Testing and Adjusting IT28F INTEGRATED TOOLCARRIER POWER TRAIN Testing And Adjusting Introduction Reference: For Specifications with illustrations, refer to SENR5974, IT28F Integrated Toolcarrier Power

More information

Service and Parts Manual. Minimum Filtration Required:

Service and Parts Manual. Minimum Filtration Required: R GRESEN Hydraulics Model V0 Sectional Body Directional Control Valve Service and Parts Manual Maximum Operating Pressure: Minimum Filtration Required: 00 PSI ( bar) 0 Micron The information in this Service

More information

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER I. REFERENCE: 1 30 [1] Snow Engineering Co. Drawing 80504 Sheet 21, Hydraulic Schematic [2] Snow Engineering Co. Drawing 60445, Sheet 21 Control Logic Flow Chart [3] Snow Engineering Co. Drawing 80577,

More information

Section 10. Pressure Adjustments For: L90F-622 LUMBERJACK

Section 10. Pressure Adjustments For: L90F-622 LUMBERJACK Section 10 Pressure Adjustments For: L90F-622 LUMBERJACK 80-1009-047622 Rev 2/2013 Table of Contents Transmission Pressure Checks... 1 Accumulator Charge Pressure Adjustments... 2-3 Valve Adjustments...

More information

OCTOPUS SELECTION & INSTALLATION GUIDE

OCTOPUS SELECTION & INSTALLATION GUIDE OCTOPUS SELECTION & INSTALLATION GUIDE CRB SERIES CONTINUOUS RUNNING PUMPSET A. GENERAL DESCRIPTION: Octopus CRB pumpsets are heavy duty, continuously running, electric motor driven pumps which are used

More information

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information Series 20 Axial Piston Pumps Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston pumps. DESCRIPTION Sauer-Danfoss

More information

TF820-D Forwarder. D Model Improvements & Features. Lift Capacities (w/hultdin s 360S grapple)

TF820-D Forwarder. D Model Improvements & Features. Lift Capacities (w/hultdin s 360S grapple) TF820-D Forwarder Log Bunk Cross-Section Area 42.41 ft. 2-48.51 ft. 2 (3.94 m 2-4.51 m 2 ) 67 (170 cm) 194 (493 cm) 31 7 (9,63 m) 8 (20 cm) 7 9 (2,36 m) D Model Improvements & Features Short center-to-center

More information

Filling and Flushing the Hydraulic System - Test

Filling and Flushing the Hydraulic System - Test Filling and Flushing the Hydraulic System - Test Personal injury or death can result from improperly checking for a leak. Always use a board or cardboard when checking for a leak. Escaping air or fluid

More information

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information Series 20 Axial Piston Pumps Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston pumps. DESCRIPTION Sauer-Danfoss

More information

Hydraulic Pump Series VP1 Variable Displacement

Hydraulic Pump Series VP1 Variable Displacement Variable Displacement Catalog 9129 8222-02 February 1999, GB Content Page General information 3 Design 3 Specifications 4 Ordering information 4 VP1 cross section 4 Installation dimensions 5 Line dimensioning

More information

oubleshooting Guide diesel - gasoline - LPG electric P.O. Box 1160 St. Joseph, MO Fax:

oubleshooting Guide diesel - gasoline - LPG electric P.O. Box 1160 St. Joseph, MO Fax: Troub oubleshooting Guide diesel - gasoline - LPG electric P/N 0162737 October 2005 P.O. Box 1160 St. Joseph, MO 64502-1160 1-800-255-0317 Fax: 785-989-3075 www.snorkelusa.com GENERAL INFORMATION This

More information

Section DH-1. Drive Hydraulics - Charge Pressure Circuit. Drive Hydraulics - Charge Pressure Circuit

Section DH-1. Drive Hydraulics - Charge Pressure Circuit. Drive Hydraulics - Charge Pressure Circuit Section DH-1 Drive Hydraulics - Charge Pressure Circuit Drive Hydraulics - Charge Pressure Circuit Last Updated - 04/15 Drive Hydraulics - Charge Pressure Circuit Parts T4022 4/15 25.00 700C Parts DH-R0

More information

200C II BRAKE SYSTEM

200C II BRAKE SYSTEM 200C II BRAKE SYSTEM The braking system on the 200C II Kress Coal Hauler uses hydraulic oil pressure from both the System and Steering accumulator circuits. Using oil from both circuits provides braking

More information

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001-14001 ISO 9001 Via M. L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415

More information

ARMTRAC 75T-230 CAB SPECIFICATIONS T H I S I S A C O N T R O L L E D D O C U M E N T. SPEC/A75T/1CAB/3.00/ Page 1 of 5

ARMTRAC 75T-230 CAB SPECIFICATIONS T H I S I S A C O N T R O L L E D D O C U M E N T. SPEC/A75T/1CAB/3.00/ Page 1 of 5 ARMTRAC 75T-230 CAB SPECIFICATIONS SPEC/A75T/1CAB/3.00/08.2018 Page 1 of 5 SPEC/A75T/1CAB/3.00/08.2018 Page 2 of 5 STATIC DIMENSIONS A Track length (Diameter) 3091 mm H Track width outside 2023.5 mm B

More information

Section 5: Hydraulic Pump SAUER DANFOSS. SERVICE MANUAL Property of American Airlines. 5-5 Page 1 September 09 HYDRAULIC PUMP

Section 5: Hydraulic Pump SAUER DANFOSS. SERVICE MANUAL Property of American Airlines. 5-5 Page 1 September 09 HYDRAULIC PUMP Section 5: Hydraulic Pump SAUER DANFOSS SERVICE MANUAL HYDRAULIC PUMP 5-5 Page 1 September 09 THIS PAGE INTENTIONALLY LEFT BLANK Series 45 Frame G and H Open Circuit Axial Piston Pumps Service Manual Introduction

More information

Kit. Hydraulic Kit Installation Guide REV B Table 1 Component List. Item Component Part Number Qty

Kit. Hydraulic Kit Installation Guide REV B Table 1 Component List. Item Component Part Number Qty Hydraulic Kit Installation Guide Table 1 Component List Item Component Part Number Qty 1. Hose 5/8 X 36-8F X -12F 90 DEG ORFS F451TC-JSJ9081210-36 2 2. HOSE ASSY. 1/4" X 36" -4F X -6F ORFS F451TC-JCJC040604-36

More information

Truck Hydraulics. Serie VP1 Variable Displacement Pumps

Truck Hydraulics. Serie VP1 Variable Displacement Pumps ruck Hydraulics Variable Displacement Pumps aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Contents Pump and line

More information

2. Power Steering System

2. Power Steering System 2. Power Steering System A: HYDRAULIC SYSTEM POWER STEERING SYSTEM The fluid pump is directly driven by the engine through a belt. The fluid flow is maintained almost constant regardless of change in the

More information

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS Directional Control Valves LOAD SENSE SECTIONS NEED NEW PIC Series 20 STANDARD FEATURES Control and reduced Dead Band (20I) and Tie Rod Kits SPECIFICATIONS Pressure Rating Foot Mounting Maximum Operating

More information

BRAKE SYSTEM, HYDRAULICALLY ACTUATED - 631G TRACTOR Cat Tractors with standard shoe/drum brakes

BRAKE SYSTEM, HYDRAULICALLY ACTUATED - 631G TRACTOR Cat Tractors with standard shoe/drum brakes BRAKE SYSTEM, HYDRAULICALLY ACTUATED - 631G TRACTOR 194139 631 Cat Tractors with standard shoe/drum brakes Kress Corporation modifies the Caterpillar tractor air actuated shoe brake system to a hydraulically

More information

three different ways, so it is important to be aware of how flow is to be specified

three different ways, so it is important to be aware of how flow is to be specified Flow-control valves Flow-control valves include simple s to sophisticated closed-loop electrohydraulic valves that automatically adjust to variations in pressure and temperature. The purpose of flow control

More information

Model No. LG55-3PT 55 Gallon Sprayer 3 Point Lawn & Garden Sprayer Model No. LG27-3PT 25 Gallon Sprayer GENERAL INFORMATION

Model No. LG55-3PT 55 Gallon Sprayer 3 Point Lawn & Garden Sprayer Model No. LG27-3PT 25 Gallon Sprayer GENERAL INFORMATION 5300587 Model No. LG27-3PT 25 Gallon Sprayer 5300576 Model No. LG55-3PT 55 Gallon Sprayer 3 Point Lawn & Garden Sprayer Join the center boom to the carrier frame with the two u-bolts, and flange locknuts.

More information

WORKHORSE. Assembly / Operation Instructions / Parts

WORKHORSE. Assembly / Operation Instructions / Parts WORKHORSE S P R A Y E R S Assembly / Operation Instructions / Parts by, a Division of Green Leaf, Inc ATV 2522 MODEL # ATV 2522 DELUXE ATV 2 NOZZLE SPRAYER GENERAL INFORMATION WARRANTY / PARTS / SERVICE

More information

Introduction. Installation. Maintenance. Bill of Materials

Introduction. Installation. Maintenance. Bill of Materials Table of Contents Introduction Specitications... 3 Operation... 4 Installation New Installations... 6 Retrofit Installations... 6 Flow Control Switch... 7 Dimensions... 8 E-7 Valve... 28 E-7 Valve with

More information

BRAKE E

BRAKE E 8-1 GENERAL...8-2 SPECIFICATIONS...8-6 COMPONENTS...8-7 FRONT BRAKE...8-12 DISASSEMBLY INSPECTION REASSEMBLY (Pn1, Cu2 3 TON SERIES)...8-12 DISASSEMBLY INSPECTION REASSEMBLY (Pn2 3 TON SERIES)...8-17 BRAKE

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : TAP- IN KIT 5100-5151 BAYNE MACHINE WORKS, INC. PHONE: (864) 288-3877 910 FORK SHOALS ROAD TOLL FREE: (800) 535-2671 GREENVILLE S.C., 29605 FAX:

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 13 Pumps and Accessory Equipment Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 13 Pumps and Accessory Equipment Revised DRIVER OPERATOR Page 1 of 13 PUMPS AND ACCESSORY EQUIPMENT Pumps are designed for many different purposes. In order to understand the proper application and operation of a pump in a given situation, firefighters

More information

ARMTRAC 75T-230 CABLESS

ARMTRAC 75T-230 CABLESS ARMTRAC 75T-230 CABLESS SPECIFICATIONS SPEC/A75T/0CAB/2.00/08.2018 Page 1 of 5 E 45 C F S B A D Machine - At widest points N M J G H I L K SPEC/A75T/0CAB/2.00/08.2018 Page 2 of 5 STATIC DIMENSIONS A Track

More information

Directional Control Valve

Directional Control Valve Directional Control Valve Service and Parts Manual powersolutions.danfoss.com Directional Control Valves Service and Parts Manual: Contents SERVICE PARTS Inlet cover... 3-4 Outlet cover... 5-6 Standard

More information

Flow sharing control block in mono block / sandwich plate design M6-22

Flow sharing control block in mono block / sandwich plate design M6-22 Flow sharing control block in mono block / sandwich plate design M6-22 RE 64322 Edition: 01.2015 Replaces: 05.2012 Size 22 Series 3X Maximum operating pressure on pump side 350 bar on consumer side 420

More information

Axial Piston Variable Pump AA4VG

Axial Piston Variable Pump AA4VG Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Axial Piston Variable Pump AA4VG RA 92003-A/06.09 1/64 Replaces: 03.09 Data sheet Series 32 Size 28...

More information

DENISON HYDRAULICS Premier Series. open circuit pump controls P16 B-mod, P09 A-mod. service information

DENISON HYDRAULICS Premier Series. open circuit pump controls P16 B-mod, P09 A-mod. service information DENISON HYDRAULICS Premier Series open circuit pump controls P6 B-mod, P0 A-mod service information Publ. S-AM06-A replaces S-AM06 Internet: http://www.denisonhydraulics.com E-mail: denison@denisonhydraulics.com

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL DH0606 14G36 Connect and Cut Hydraulic Chain Information subject to change without notice. SAFETY PRECAUTIONS The unit you have purchased may require you to install additional

More information

HYDRAULICS. TX420 & & lower. Hydraulic Tandem Pump Removal. 4. Remove the LH side panel (Fig. 0388).

HYDRAULICS. TX420 & & lower. Hydraulic Tandem Pump Removal. 4. Remove the LH side panel (Fig. 0388). TX420 & 425 240000299 & lower 4. Remove the LH side panel (Fig. 0388). Hydraulic Tandem Pump Removal Note: Cleanliness is a key factor in a successful repair of any hydraulic system. Thoroughly clean all

More information

DENISON HYDRAULICS open loop pump controls series P140 A-mod, P260 B-mod service information

DENISON HYDRAULICS open loop pump controls series P140 A-mod, P260 B-mod service information DENISON HYDRAULICS open loop pump controls series P10 A-mod, P260 B-mod service information Publ. S1-AM02-A replaces S1-AM02 01-97 CONTENTS typical characteristics-------------------------------------------------------------------------------

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide diesel - gasoline - LPG P/N 0172021 June 1999 P.O. Box 1160 St. Joseph, MO 64502-1160 1-800-255-0317 Fax: 816-360-9379 www.snorkelusa.com GENERAL INFORMATION This manual contains

More information

2.3 MEDIUM HEAVY DUTY SERIES

2.3 MEDIUM HEAVY DUTY SERIES 2 2.3 MEDIUM HEAVY DUTY SERIES CONTENTS PPV11 Ordering Code 2.3.1 Medium Heavy Duty Series 2.3.2 Torque limiter settings Technical Information 2.3.3 Specifications 2.3.4 Hydraulic fluids 2.3.5 Viscosity

More information

WARCO CHEMAG SERIES GH FILTERS

WARCO CHEMAG SERIES GH FILTERS WARCO CHEMAG SERIES GH FILTERS High Performance Pleated & Bag Type Filtration Systems INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Thank you for your purchase of a WARCO Series GH Filtration System.

More information

DENISON HYDRAULICS Premier Series. open loop pump controls series P080. service information

DENISON HYDRAULICS Premier Series. open loop pump controls series P080. service information DENISON HYDRAULICS Premier Series open loop pump controls series P080 service information Publ. S-AM0 Internet: http://www.denisonhydraulics.com E-mail: denison@ denisonhydraulics.com CONTENTS typical

More information

Pump model PVPP-*-3023 PVPP-*-3033 PVPP-*-4048 PVPP-*-5060 PVPP-* Max flow at 1500 rpm and 7 bar [l/min]

Pump model PVPP-*-3023 PVPP-*-3033 PVPP-*-4048 PVPP-*-5060 PVPP-* Max flow at 1500 rpm and 7 bar [l/min] 900 Table A0obs/E Axial piston pumps type PVPP, variable displacement, high pressure operation Hydraulic and electrohydraulic control obsolete components - availability on request PVPP-SLER-08/D PVPP are

More information

Definitions of Technical Terms

Definitions of Technical Terms Definitions of Technical Terms ABSOLUTE A measure having as it s zero point of base the complete absence of the entity being measured. ABSOLUTE PRESSURE A pressure scale with zero point at a perfect vacuum.

More information

MCV106A. Hydraulic Displacment Control-PV DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: March 1991

MCV106A. Hydraulic Displacment Control-PV DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: March 1991 DESCRIPTION MCV106A Hydraulic Displacment Control-PV Issued: March 1991 The MCV106A Hydraulic Displacement Control (HDC) is a costeffective hydraulic pump stroke control which uses mechanical feedback

More information

PISTON MOTORS FOR CLOSED LOOP SYSTEMS types HMF/A/V/R-02

PISTON MOTORS FOR CLOSED LOOP SYSTEMS types HMF/A/V/R-02 1-control optional swashing to 0 cc /rev 2-swash plate hydrostatic bearing 3-piston-slipper assembly 21 swash angle 4-housing monoshell for high rigidity 5-valve plate housing highly integrated 6-control

More information

Filling and Flushing the Hydrostatic System

Filling and Flushing the Hydrostatic System Filling and Flushing the Hydrostatic System Sudden movement of the machine or release of oil under pressure can cause injury to persons on or near the machine. To prevent possible injury, perform the procedure

More information

CHAPTER 29 HYDRAULICS Description Hydraulic Pump Hydraulic Reservoir Hydraulic Servos

CHAPTER 29 HYDRAULICS Description Hydraulic Pump Hydraulic Reservoir Hydraulic Servos Section Title CHAPTER 29 HYDRAULICS 29-00 Description............................................... 29.1 29-10 Hydraulic Pump............................................ 29.1 29-20 Hydraulic Reservoir.........................................

More information

MODEL 10LH SPECIFICATION

MODEL 10LH SPECIFICATION MODEL 10LH SPECIFICATION 1.0 General Specifications There will be furnished one (1) only Grind Hog TM Model 10LH Comminutor as manufactured by G.E.T. Industries, Inc. Rotation shall be in a clockwise (standard)

More information

Variable Axial Piston Eaton Vickers PVH Pump

Variable Axial Piston Eaton Vickers PVH Pump Variable Axial Piston Eaton Vickers PVH Pump PVH High pressure axial piston pumps with low noise PVH high flow, high performance pumps are a family of variable displacement, inline piston units that incorporate

More information

Radial piston motor for compact drives MCR-C

Radial piston motor for compact drives MCR-C Radial piston motor for compact drives MCR-C RE 15197 Edition: 02.2017 Replaces: 12.2013 Frame size MCR20 Displacement 1750 cc to 3000 cc Differential pressure up to 450 bar Torque output up to 19099 Nm

More information

REPAIR MANUAL AFX8010

REPAIR MANUAL AFX8010 REPAIR MANUAL AFX 1 27/05/2004 Contents INTRODUCTION DISTRIBUTION SYSTEMS POWER PRODUCTION POWER TRAIN TRAVELLING BODY AND STRUCTURE TOOL POSITIONING CROP PROCESSING A B C D E G K AFX 1 27/05/2004 INTRODUCTION

More information

Troubleshooting The Transmission Hydraulic System

Troubleshooting The Transmission Hydraulic System 416B, 426B, 428B, 436B, & 438B BACKHOE LOADERS TRANSMISSION Testing And Adjusting Troubleshooting The Transmission Hydraulic System Make reference to the following warning and pressure tap locations for

More information

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit Introduction *not included Pump with standard compensator, code: "omit" With thru shaft option for multiple pump options Swash plate type for open circuit Pump with load sensing, code: "A" Mounting style

More information

Section 4.3. Machine Operation - Operating Procedures. Before Starting the Engine: General Pre-Start Inspection

Section 4.3. Machine Operation - Operating Procedures. Before Starting the Engine: General Pre-Start Inspection Section 4.3 Machine Operation - Operating Procedures Before Starting the Engine: General Pre-Start Inspection... 4.3.2 Engine Starting Procedure... 4.3.2 Cold Weather Start-Up... 4.3.3 Engine Shutdown

More information

BLACKMER PISTON AIR VALVE SAFETY DATA. For Piston Air Valve Style AVC and Discontinued Style AVB TABLE OF CONTENTS SAFETY DATA...

BLACKMER PISTON AIR VALVE SAFETY DATA. For Piston Air Valve Style AVC and Discontinued Style AVB TABLE OF CONTENTS SAFETY DATA... BLACKMER PISTON AIR VALVE 960333 INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS WITH PARTS LIST For Piston Air Valve Style AVC and Discontinued Style AVB Page 1 of 8 Section Effective Replaces INSTRUCTIONS

More information

Location of Hydraulic Components SMCS

Location of Hydraulic Components SMCS Unfiled Notes Page 1 Service Information System Monday, May 09, 2016 1:42 PM Systems Operation D6T Track-Type Tractor Hydraulic System Media Number -KENR5129-04 Publication Date -01/08/2014 Date Updated

More information

Marine Engineering Exam Resource Review of Hydraulics

Marine Engineering Exam Resource Review of Hydraulics 1. What is Pascal s law? Pressure confined on a confined fluid will transmit the pressure in all directions and act with equal force on all areas at right angles. 2. How does the law pertain to hydraulics?

More information

Radial piston motor for frame integrated drives MCR-A

Radial piston motor for frame integrated drives MCR-A Radial piston motor for frame integrated drives MCR-A RE 15195 Edition: 12.2013 Frame size MCR3, MCR5, MCR10 Displacement 160 cc to 1340 cc Differential pressure up to 450 bar Torque output up to 8530

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide diesel - gasoline - LPG diesel - gasoline - LPG diesel - gasoline - LPG P/N 0191681 May, 1999 An ISO 9001 Registered Company P.O. Box 1160 St. Joseph, MO 64502-1160 1-800-255-0317

More information

STEERING HYDRAULICS The steering system is a flow amplified, load sensing, hydraulics arrangement.

STEERING HYDRAULICS The steering system is a flow amplified, load sensing, hydraulics arrangement. STEERING HYDRAULICS 116821 The steering system is a flow amplified, load sensing, hydraulics arrangement. When the steering wheel is turned, the Steering Metering Pump meters an oil volume proportional

More information

2004 Volvo C70 L5-2.4L Turbo VIN 63 B5244T7 Cylinder Head Assembly Service and Repair, Removal and Replacement: Cylinder Head/Gasket, Replacing

2004 Volvo C70 L5-2.4L Turbo VIN 63 B5244T7 Cylinder Head Assembly Service and Repair, Removal and Replacement: Cylinder Head/Gasket, Replacing 1 of 25 8/18/2011 6:10 PM 2004 Volvo C70 L5-2.4L Turbo VIN 63 B5244T7 Cylinder Head Assembly Service and Repair, Removal and Replacement: Cylinder Head/Gasket, Replacing Cylinder head/gasket, replacement

More information

ROGERS MACHINERY COMPANY, INC

ROGERS MACHINERY COMPANY, INC KOBELCO KNW SERIES Sample Specifications AIR-COOLED, OIL-FREE AIR COMPRESSOR Frame 0, 1, 2 50 500 HP ROGERS 2110_KA.doc Effective: 03-24-17 Supersedes: 04-06-15 Page 1 of 9 1. SPECIFICATIONS SCOPE 1.1

More information

Series PAVC Variable Volume, Piston Pumps

Series PAVC Variable Volume, Piston Pumps Series PVC Variable Volume, Piston Pumps Catalog 26-11-1/US 95 Introduction Series PVC Quick Reference Data Chart Pump Model Displacement CM 3 /REV (IN 3 /REV) Pump Delivery *pprox. Noise Levels db() Input

More information

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP KOBELCO KNW SERIES 1 OF 10 1. SPECIFICATIONS SCOPE 1.1 This specification covers the requirement for supply of a packaged oil-free rotary screw air compressor, Kobelco KNW Series model. 1.2 Any and all

More information

350 MH. Material Handler

350 MH. Material Handler 0 MH Material Handler The Cat 0 Material Handler is specifically designed for the scrap and material handling customer. This machine uses the most sophisticated manufacturing technology to ensure the highest

More information

Kit. Hydraulic Kit Installation A. Item Component Part Number Qty

Kit. Hydraulic Kit Installation A. Item Component Part Number Qty Hydraulic Kit Installation Item Component Part Number Qty 1. 2. 3. 4. Hose, 1/2 x 60-8F ORFS x -8F ORFS 90 Hose, 3/8 x 60-6F ORFS x -8F ORFS 90 Hose, 1/4 x 60-4F ORFS x -4F ORFS 45 Hose, 1/4 x 60-4F ORFS

More information

Type 1051 and 1052 Size 33 Diaphragm Rotary Actuator

Type 1051 and 1052 Size 33 Diaphragm Rotary Actuator Instruction Manual Type 1051 and 1052 Size 33 Diaphragm Rotary Actuator 1051 & 1052 Actuator Contents Introduction............................. 1 Scope of Manual........................... 1 Description................................

More information

LUDV control block in mono block/sandwich plate design M7-20

LUDV control block in mono block/sandwich plate design M7-20 LUDV control block in mono block/sandwich plate design M7-20 RE 64293 Edition: 06.2013 Replaces:. Size 20 Series 3X Maximum operating pressure On the pump side 380 bar On the actuator side 420 bar Maximum

More information