Hydrostatic Drive. 1. Main Pump. Hydrostatic Drive

Size: px
Start display at page:

Download "Hydrostatic Drive. 1. Main Pump. Hydrostatic Drive"

Transcription

1 Hydrostatic Drive The Hydrostatic drive is used to drive a hydraulic motor at variable speed. A bi-directional, variable displacement pump controls the direction and speed of the hydraulic motor. This type of drive is commonly called a closed loop drive. The two ports of the hydraulic pump are hydraulically connected to the two ports on the hydraulic motor forming the closed loop. 1. Main Pump A piston pump is used in a hydrostatic drive. The pump volume can be varied from 0 to maximum. In the illustration shown, the pump swashplate is in the vertical position, which means that the pump output is now 0 GPM. To drive the hydraulic motor forward, the swashplate will angle and deliver fluid out of the A port. Port B will act as the suction port. To drive the motor in reverse, the swashplate will angle in the opposite direction. The B port will then be the pressure port, and the A port will be the suction. The amount the swashplate angles in each direction determines the flow from the pump. Basic Hydrostatic Drive Page 6-20

2 2. Charge Pump This is also sometimes known as the replenishing pump. The pump is usually mounted on the back end of the main pump. The charge pump volume is normally 10-15% of the main pump. The purpose of the charge pump is to provide make up fluid to the system. On systems that use hydraulic cylinders to stroke the main pump, the charge pump supplies the fluid to the cylinders. Because of leakage at the pump and motor case drains, less oil flows out of the motor than what the main pump is actually calling for. Let s look at a typical example. Page 6-21

3 3. Charge Pump Relief Valve The charge pump relief valve provides a flow path for the excess charge pump volume to return to tank. The relief valve is normally mounted on or near the charge pump. The outlet flow of this relief valve is usually ported into the pump case. In the system shown, the charge pump relief valve setting determines the pressure on the low pressure side of the loop. This pressure is usually PSI. On systems with shuttle valves, the shuttle relief valve determines the pressure on the low side of the loop. The shuttle valve is discussed later in this section. 4. Make Up Check Valves The specific check valve permits free flow from the charge pump to the low pressure side of the loop. At the same time oil in the high pressure side is blocked to the low pressure side by the opposite check valve. The check valves are usually accessed by removing the charge pump. Hydrostatic Pump Assembly Idle Mode Page 6-22

4 Hydrostatic Pump Forward Operation Hydrostatic Pump Reverse Operation Page 6-23

5 Servo Case Drain Stroking Cylinder Charge Pump Relief Charge Pump 5. Crossport Relief Valves The crossport relief valves limit the maximum pressure in the system. If the motor should stall, the relief valve on the high pressure side would open and dump the fluid back to the suction side of the loop. The valves also absorb shock spikes in the hydraulic system. To best absorb the pressure spikes, the valve should be mounted as close to the motor as possible. Depending on the system, the valves may be located on the pump, mounted in a separate block or on the hydraulic motor. Set the valves PSI above the maximum operating pressure. Some drives may have a pressure override, which operates similarly to a pump compensator. On those systems the pressure override should be set below the crossport relief valve settings. Page 6-24

6 6. Hydraulic Motor The speed and direction of the motor is determined by the hydraulic pump. Maximum pressure to the motor is determined by the crossport relief valve settings. The motor case drain flow should be checked (if a piston type motor) and recorded for future troubleshooting purposes. On systems with shuttle valves, the tank port of the shuttle relief valve is sometimes ported into the motor case. On those systems, checking the case flow would not give an accurate indication of bypassing. Motor Stalled Page 6-25

7 Pump Control Mechanical Control The two most common methods of varying the hydrostatic pump volume is either by a mechanical connection or a servo valve. The mechanical control is by a cable or other mechanical linkage. An operator moves a joystick or foot pedal to stroke the pump. The GPM the pump delivers is directly proportional to the amount the joystick or pedal is moved. If the pump is delivering fluid when the joystick or pedal is centered, then the mechanical linkage may need to be adjusted. The mechanical control is normally found on mobile equipment and knucklebooms. Page 6-26

8 Servo Control Most hydrostatic drives operating in plants today use a servo valve to control the pump. Servo valves are explained in detail earlier in this manual. A variable D.C. voltage controls the direction and amount of flow the pump delivers. Normally a positive D.C. voltage will shift the servo spool into the A position. The amount the spool shifts is directly proportional to the strength of the voltage. The charge pump fluid is then ported out the servo valve A port and to the A cylinder. As the A cylinder extends to stroke the pump a mechanical feedback from the swashplate exerts a force on the servo valve torque motor. When the feedback force is slightly higher than the electrical force on the torque motor, the servo valve spool returns back toward center, allowing only enough oil to hold the piston in position. The fluid in the cylinder holds the pump on stroke. Oil is now delivered out of the A port of the pump. Page 6-27

9 The higher the voltage to the servo valve amplifier, the more volume the pump delivers. To reverse the flow direction out the pump, a negative voltage is applied to the amplifier. The pump will again stroke proportionally to the voltage and deliver fluid out of the B port. When there is no electrical signal to the servo valve, the pump volume output should be 0 GPM. If the hydraulic motor is drifting either the centering springs on the cylinders need adjusting or the servo valve needs to be nulled. Nulling the servo valve is discussed in detail in the servo valve section. The oil flow to the servo valve is filtered by a non-bypassing element. Most servo valves also contain a small pilot filter that has a micron rating. If either filter plugs then the pump will stroke very slowly or not at all. Shuttle Valve and Relief Valve Although all systems do not have shuttle valves, it provides for cooling part of the inline fluid. The purpose of the shuttle valve is to direct a portion of the flow exhausting out of the motor back to tank. The oil is then ported back through a cooler prior to returning to the reservoir. This permits a small volume of oil in the main system to be cooled. In the previous example, the excess charge pump oil was dumped to tank over the charge pump relief valve. On systems with shuttle valves, the shuttle relief valve is set at a lower pressure than the charge pump relief valve. The setting of the shuttle relief valve determines the pressure on the low pressure side of the loop. It is important that the pressure of the shuttle relief valve is set below the charge pump relief valve. If set above, then the excess charge pump fluid will dump through the charge pump relief valve. Page 6-28

10 The shuttle valve and relief valve are many times bolted onto the hydraulic motor. It may also be in the same block as the crossport relief valves. Forward Operation Page 6-29

11 Filtration The fluid in the hydrostatic loop constantly re-circulates except for the oil flow through the shuttle relief valve. The best filter arrangement is to filter the fluid in both directions on each side of the loop. If filtering is not done in both directions then when the pump fails, the contamination from the pump can go directly into the motor or vice-versa. The filters should have visual or electrical indicators to indicate when the elements are contaminated. Page 6-30

12 Checking the Hydrostatic Drive To effectively troubleshoot the drive some preliminary checks should be made when operating properly to establish a reference. Charge pump relief valve setting. When the main pump is off stroke, the charge pump relief valve setting will be indicated on all gauges in the system. (The exception is when a two position shuttle valve is used). Shuttle relief valve setting. Check on the low pressure side of the loop when driving the hydraulic motor. Operating pressure. Check when the drive has the heaviest load on the machine. Check in both the forward and reverse direction. Crossport relief valve settings. The lines to the hydraulic motor will have to be plugged or the motor stalled. If a pressure override is used, it s pressure setting should also be recorded. The crossport relief valves should be set PSI above the pressure override setting. Be careful not to exceed the maximum pressure of the system components when setting the crossport relief valves and pressure override. Check the command voltage to the amplifier and current to the servo valve (if used). The RPM of the hydraulic motor should be recorded for a specific D.C. signal to the servo valve. Speed problems in hydrostatic drives are usually related to either the incoming D.C. signal or the servo valve itself. Some pumps have a displacement indicator. The indicator position should also be recorded for a specific current to the servo valve. Motor case drain flow (if the motor is a piston type). As the motor wears, more oil will bypass. Be sure to check when driving the motor as excessive bypassing occurs when the pressure is at maximum. This will not be an effective check if the shuttle relief tank line is ported back through the motor case. Page 6-31

13 Filter indicators. Filters usually have a color coded or other visual indicator to show the element condition. If the elements are partially plugged on non bypassing type filters, the drive will slow down. The filters should be checked and changed as necessary on a regularly scheduled basis. Page 6-32

GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc

GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc Hydraulic Consulting, Inc This special promotional CD is to demonstrate how your hydraulic troubleshooting manual can be ordered as an Adobe Acrobat ebook. It can be installed on any computer with the

More information

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls. Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls. Standard Check Valve The standard check valve permits free flow in one direction

More information

Servo and Proportional Valves

Servo and Proportional Valves Servo and Proportional Valves Servo and proportional valves are used to precisely control the position or speed of an actuator. The valves are different internally but perform the same function. A servo

More information

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel Section 7.1 Track Drive Circuit - General System Simplified Travel Circuit Diagrams: Neutral Controls... 7.1.2 Forward Travel... 7.1.4 Reverse Travel... 7.1.5 General... 7.1.3 Track Drive Circuit: General...

More information

Hydrostatic Power Train

Hydrostatic Power Train Chapter Hydrostatic Power Train Specifications................................................................. -3 Test Specifications........................................................ -3 Repair

More information

Section 7.1. Wheel Drive Circuit - General System

Section 7.1. Wheel Drive Circuit - General System Section 7.1 Wheel Drive Circuit - General System Simplified Travel Circuit Diagrams: Neutral Controls... 7.1.2 Forward Travel... 7.1.4 Reverse Travel... 7.1.5 General... 7.1.3 Wheel Drive Circuit: General...

More information

LogSplitterPlans.Com

LogSplitterPlans.Com Hydraulic Pump Basics LogSplitterPlans.Com Hydraulic Pump Purpose : Provide the Flow needed to transmit power from a prime mover to a hydraulic actuator. Hydraulic Pump Basics Types of Hydraulic Pumps

More information

Troubleshooting, Service Tips, And Major Improvements For Hydrostatic Transmissions (Special Edition){3200}

Troubleshooting, Service Tips, And Major Improvements For Hydrostatic Transmissions (Special Edition){3200} Page 1 of 75 Troubleshooting, Service Tips, And Major Improvements For Hydrostatic Transmissions (Special Edition){3200} 943, 953, 963, 973 Loaders Introduction The hydrostatic transmissions used in 943,

More information

MCV106A. Hydraulic Displacment Control-PV DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: March 1991

MCV106A. Hydraulic Displacment Control-PV DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: March 1991 DESCRIPTION MCV106A Hydraulic Displacment Control-PV Issued: March 1991 The MCV106A Hydraulic Displacement Control (HDC) is a costeffective hydraulic pump stroke control which uses mechanical feedback

More information

Troubleshooting Bosch Proportional Valves

Troubleshooting Bosch Proportional Valves Troubleshooting Bosch Proportional Valves An Informative Webinar Developed by GPM Hydraulic Consulting, Inc. Instructed By Copyright, 2009 GPM Hydraulic Consulting, Inc. TABLE OF CONTENTS Bosch Valves

More information

Definitions of Technical Terms

Definitions of Technical Terms Definitions of Technical Terms ABSOLUTE A measure having as it s zero point of base the complete absence of the entity being measured. ABSOLUTE PRESSURE A pressure scale with zero point at a perfect vacuum.

More information

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve: Section 6.1 Implement Circuit - General System General: TF Configuration... 6.1.3 TB Configurations... 6.1.5 Implement Pump Breakdown... 6.1.6 Operational Description: General... 6.1.7 Compensator Control...

More information

Axial Piston Pumps and Motors Service Manual

Axial Piston Pumps and Motors Service Manual Axial Piston Pumps and Motors Service Manual Introduction Introduction Use of this Manual This manual includes information for the normal operation, maintenance, and servicing of the Series 90 family of

More information

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve: Section 6.1 Implement Circuit - General System General: TF Configuration... 6.1.3 TB Configurations... 6.1.5 Implement Pump Breakdown... 6.1.6 Operational Description: General... 6.1.7 Compensator Control...

More information

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM, Testing And Adjusting Introduction NOTE: For Specifications with illustrations, make reference to SPECIFICATIONS for 225 EXCAVATOR HYDRAULIC SYSTEM, Form No. SENR7734. If the Specifications are not the

More information

Fluid Maintenance. The hydraulic oil performs four functions in the hydraulic system:

Fluid Maintenance. The hydraulic oil performs four functions in the hydraulic system: The hydraulic oil performs four functions in the hydraulic system: Transmits Energy Coolant Lubricant Sealant Viscosity Viscosity is the rating of the oil thickness or resistance to flow. Viscosity is

More information

three different ways, so it is important to be aware of how flow is to be specified

three different ways, so it is important to be aware of how flow is to be specified Flow-control valves Flow-control valves include simple s to sophisticated closed-loop electrohydraulic valves that automatically adjust to variations in pressure and temperature. The purpose of flow control

More information

CLOSED CIRCUIT HYDROSTATIC TRANSMISSION

CLOSED CIRCUIT HYDROSTATIC TRANSMISSION Energy conservation and other advantages in Mobile Equipment Through CLOSED CIRCUIT HYDROSTATIC TRANSMISSION C. Ramakantha Murthy Technical Consultant Various features/advantages of HST Hydrostatic transmissions

More information

Module 6 Assignment Part A

Module 6 Assignment Part A Module 6 Assignment Part A TOTAL MARKS Part A = 192 TOTAL QUESTIONS Part A = 36 Question 1 [3 Marks] What does pressure refer to in relation to hydrostatics and what is it dependent on? Question 2 [14

More information

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve: Section 6.1 Implement Circuit - General System General: TF Configuration... 6.1.3 TB Configurations... 6.1.5 Implement Pump Breakdown... 6.1.6 Operational Description: General... 6.1.7 Compensator Control...

More information

STEERING HYDRAULICS The steering system is a flow amplified, load sensing, hydraulics arrangement.

STEERING HYDRAULICS The steering system is a flow amplified, load sensing, hydraulics arrangement. STEERING HYDRAULICS 116821 The steering system is a flow amplified, load sensing, hydraulics arrangement. When the steering wheel is turned, the Steering Metering Pump meters an oil volume proportional

More information

GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc

GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc Hydraulic Consulting, Inc This special promotional CD is to demonstrate how your hydraulic troubleshooting manual can be ordered as an Adobe Acrobat ebook. It can be installed on any computer with the

More information

Section 6.1. Implement Circuit - General System. General: Implement Control Valve:

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Section 6.1 Implement Circuit - General System General: Implement Circuit... 6.1.3 Implement Pump Breakdown... 6.1.4 Operational Description: General... 6.1.5 Compensator Control... 6.1.6 Standby Condition...

More information

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Implement Circuit

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Implement Circuit Section 6.1 Implement Circuit - General System General: Implement Circuit... 6.1.3 Implement Pump Breakdown... 6.1.4 Operational Description: General... 6.1.5 Compensator Control... 6.1.6 Standby Condition...

More information

2. Hydraulic Valves, Actuators and Accessories. 24 Marks

2. Hydraulic Valves, Actuators and Accessories. 24 Marks 2. Hydraulic Valves, Actuators and Accessories 24 Marks Co related to chapter 602.2 Describe working principle of various components used in hydraulic & pneumatic systems. 602.3 Choose valves, actuators

More information

LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks:

LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks: LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES STP Tasks: 552-758-1003 552-758-1071 OVERVIEW LESSON DESCRIPTION: In this lesson you will

More information

Introduction. General Information. Systems Operation

Introduction. General Information. Systems Operation Systems Operation Introduction Reference: For illustrated Specifications, refer to the Specifications For 416, 426, 428, 436, 438, & Series II Backhoe Loaders Transmission, Form No. SENR3131. If the specifications

More information

Hydraulic Maintenance & Troubleshooting. Content - Norman Kronowitz Presenter Jim Trinkle

Hydraulic Maintenance & Troubleshooting. Content - Norman Kronowitz Presenter Jim Trinkle Hydraulic Maintenance & Troubleshooting Content - Norman Kronowitz Presenter Jim Trinkle Introduction Welcome to the CMA/Flodyne/Hydradyne s Hydraulic Troubleshooting presentation. We will introduce many

More information

Pilot Oil Supply Circuit

Pilot Oil Supply Circuit Pilot Oil Supply Circuit Introduction Pilot system oil output from pilot pump (42) has the following three main functions: 1. To control main pump output. 2. To provide easier operation of control levers.

More information

What does pressure refer to in relation to hydrostatics and what is it dependent on?

What does pressure refer to in relation to hydrostatics and what is it dependent on? Question 1 [3 Marks] What does pressure refer to in relation to hydrostatics and what is it dependent on? Question 2 [14 Marks] Make a circuit diagram of a regular hydraulic plant that is used to control

More information

MP18/SIC & SIO Stacking Valve System Technical Information Manual

MP18/SIC & SIO Stacking Valve System Technical Information Manual Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service MP18/SIC & SIO Stacking Valve System Technical Information Manual The Drive & Control Company Copyright

More information

Job Sheet 1 Introduction to Fluid Power

Job Sheet 1 Introduction to Fluid Power Job Sheet 1 Introduction to Fluid Power Fluid Power Basics Fluid power relies on a hydraulic system to transfer energy from a prime mover, or input power source, to an actuator, or output device (Figure

More information

Chapter 13: Application of Proportional Flow Control

Chapter 13: Application of Proportional Flow Control Chapter 13: Application of Proportional Flow Control Objectives The objectives for this chapter are as follows: Review the benefits of compensation. Learn about the cost to add compensation to a hydraulic

More information

Lecture 6. Systems review exercise To be posted this weekend Due next Friday (3/6)

Lecture 6. Systems review exercise To be posted this weekend Due next Friday (3/6) 150 Systems review exercise To be posted this weekend Due next Friday (3/6) Lecture 6 Coming week: Lab 13: Hydraulic Power Steering Lab 14: Integrated Lab (Hydraulic test bench) Topics today: Pumps and

More information

Lecture 7. Lab 14: Integrative lab (part 2) Lab 15: Intro. Electro-hydraulic Control Setups (2 sessions)

Lecture 7. Lab 14: Integrative lab (part 2) Lab 15: Intro. Electro-hydraulic Control Setups (2 sessions) Coming week s lab: Lecture 7 Lab 14: Integrative lab (part 2) Lab 15: Intro. Electro-hydraulic Control Setups (2 sessions) 4 th floor Shepherd (room # TBD) Guest lecturer next week (10/30/15): Dr. Denis

More information

Heavy Duty Hydrostatic Transmissions

Heavy Duty Hydrostatic Transmissions Heavy Duty Hydrostatic Transmissions Features and Benefits Typical Applications Construction Transit Mixer Road Roller Paver Motor Grader Loader Dozer Material Handling & Utility Crane Sweeper Lift Truck

More information

MP18 Stacking Valve System Technical Information Manual

MP18 Stacking Valve System Technical Information Manual Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service MP18 Stacking Valve System Technical Information Manual The Drive & Control Company Copyright 1996 Bosch

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 13 Pumps and Accessory Equipment Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 13 Pumps and Accessory Equipment Revised DRIVER OPERATOR Page 1 of 13 PUMPS AND ACCESSORY EQUIPMENT Pumps are designed for many different purposes. In order to understand the proper application and operation of a pump in a given situation, firefighters

More information

Torque Converter, Transmission Pump, Screen And Filter

Torque Converter, Transmission Pump, Screen And Filter Page 13 of 27 Transmission Hydraulic System In Forward (Engine Running - Type 2 & 3 Control Valve Shown) (4) Transmission control valve. (5) Neutralizer valve. (6) Neutralizer solenoid. (7) Flow control

More information

Starting up hydraulic systems

Starting up hydraulic systems General / Installation A hydraulic system that operates economically, safely, and trouble-free requires careful planning, as well as proper installation and start-up. Conscientious maintenance has a considerable

More information

Series 51. Bent Axis Variable Motors Service Manual

Series 51. Bent Axis Variable Motors Service Manual Series 51 Bent Axis Variable Motors Service Manual General Description Series 51 Variable Displacement Motors are bent axis design units, incorporating spherical pistons. These motors are designed primarily

More information

Hydrostatic System - Test and Adjust

Hydrostatic System - Test and Adjust Testing and Adjusting 236B, 246B, 252B and 262B Skid Steer Loaders Hydraulic System Media Number -RENR4867-03 Publication Date -01/11/2009 Date Updated -24/11/2009 Hydrostatic System - Test and Adjust

More information

Hydraulic energy control, conductive part

Hydraulic energy control, conductive part Chapter 2 2 Hydraulic energy control, conductive part Chapter 2 Hydraulic energy control, conductive part To get the hydraulic energy generated by the hydraulic pump to the actuator, cylinder or hydraulic

More information

Section 35 Chapter 2 HYDRAULIC SYSTEM HOW IT WORKS AND TROUBLESHOOTING NH

Section 35 Chapter 2 HYDRAULIC SYSTEM HOW IT WORKS AND TROUBLESHOOTING NH Section 35 Chapter HYDRAULIC SYSTEM HOW IT WORKS AND TROUBLESHOOTING 6-80NH TABLE OF CONTENTS GENERAL INTRODUCTION... 35-3 Hydraulic Pumps... 35-3 Standard Flow PFC Pump Layout... 35-5 MegaFlow PFC Pump

More information

Troubleshooting The Transmission Hydraulic System

Troubleshooting The Transmission Hydraulic System 416B, 426B, 428B, 436B, & 438B BACKHOE LOADERS TRANSMISSION Testing And Adjusting Troubleshooting The Transmission Hydraulic System Make reference to the following warning and pressure tap locations for

More information

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001-14001 ISO 9001 Via M. L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415

More information

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information Series 20 Axial Piston Pumps Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston pumps. DESCRIPTION Sauer-Danfoss

More information

DENISON HYDRAULICS Premier Series. open circuit pump controls P16 B-mod, P09 A-mod. service information

DENISON HYDRAULICS Premier Series. open circuit pump controls P16 B-mod, P09 A-mod. service information DENISON HYDRAULICS Premier Series open circuit pump controls P6 B-mod, P0 A-mod service information Publ. S-AM06-A replaces S-AM06 Internet: http://www.denisonhydraulics.com E-mail: denison@denisonhydraulics.com

More information

Series 2 Variable Displacement Piston Pump

Series 2 Variable Displacement Piston Pump Series 2 Variable Displacement Piston Pump ACL 64-105cm 3 /r (3.9-6.4in 3 /r) 2 eaton Series 2 Variable Displacement Piston Pump E-PUPI-MC004-E1 January 2010 Series 2 Variable Displacement Piston Pump

More information

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed

More information

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information Series 20 Axial Piston Pumps Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston pumps. DESCRIPTION Sauer-Danfoss

More information

Eaton. Revised June, Heavy Duty Hydrostatic Transmissions. l r. Models 33 through 76 Hydrostatic Transmissions. We Manufacture.

Eaton. Revised June, Heavy Duty Hydrostatic Transmissions. l r. Models 33 through 76 Hydrostatic Transmissions. We Manufacture. s Eaton Revised June, 1997 c Heavy Duty Hydrostatic Transmissions h i y d l ydraulics r a u u l c a i r s y d Models 33 through 76 Hydrostatic Transmissions We Manufacture Solutions H S o l u t i o n s

More information

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit Introduction *not included Pump with standard compensator, code: "omit" With thru shaft option for multiple pump options Swash plate type for open circuit Pump with load sensing, code: "A" Mounting style

More information

Axial piston variable pump A15VSO, A15VLO series 10 (US-Version)

Axial piston variable pump A15VSO, A15VLO series 10 (US-Version) xial piston variable pump 15VO, 15VLO series 10 (U-Version) R- 92800 Edition: 11.2013 Replaces:. izes 110 to 280 Nominal pressure 5100 psi (350 bar) Maximum pressure 6100 psi (420 bar) Open circuit Features

More information

Power Train. Chapter 5

Power Train. Chapter 5 Chapter Power Train Spefications................................................................. -3 Test Spefications........................................................ -3 Repair Spefications.......................................................

More information

Lesson 5: Directional Control Valves

Lesson 5: Directional Control Valves : Directional Control Valves Basic Hydraulic Systems Hydraulic Fluids Hydraulic Tank Hydraulic Pumps and Motors Pressure Control Valves Directional Control Valves Flow Control Valves Cylinders : Directional

More information

VINCKE HYDRAULIC PUMPS

VINCKE HYDRAULIC PUMPS : VNK BA10VS 21 Variable displacement axial piston pump of swashplate design for hydraulic open circuit systems. Flow is proportional to drive speed and displacement. It can be infinitely varied by adjustment

More information

Tests & Adjustments - General Machine. General Safety Hydraulic Tank Turbo Boost Regulator

Tests & Adjustments - General Machine. General Safety Hydraulic Tank Turbo Boost Regulator Section 8.1 Tests & Adjustments - General Machine General Safety......................................... 8.1.2 Hydraulic Tank Turbo Boost Regulator........................ 8.1.2 Hydraulic Tank Safety

More information

Series PAVC Variable Volume, Piston Pumps

Series PAVC Variable Volume, Piston Pumps Series PVC Variable Volume, Piston Pumps Catalog 26-11-1/US 95 Introduction Series PVC Quick Reference Data Chart Pump Model Displacement CM 3 /REV (IN 3 /REV) Pump Delivery *pprox. Noise Levels db() Input

More information

DENISON HYDRAULICS open loop pump controls series P140 A-mod, P260 B-mod service information

DENISON HYDRAULICS open loop pump controls series P140 A-mod, P260 B-mod service information DENISON HYDRAULICS open loop pump controls series P10 A-mod, P260 B-mod service information Publ. S1-AM02-A replaces S1-AM02 01-97 CONTENTS typical characteristics-------------------------------------------------------------------------------

More information

Hydraulic Power Supply and Motors Concept and Theory

Hydraulic Power Supply and Motors Concept and Theory Hydraulic Power Supply and Motors Concept and Theory Graco, Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 1996 Graco Inc. Form No. 321-046 1/96 Rev 2 SL Training 11/14 Hydraulic Systems Component Identification

More information

Fluidics. Hydraulic circuit. Course teacher Prof. Mahbubur Razzaque

Fluidics. Hydraulic circuit. Course teacher Prof. Mahbubur Razzaque COURSE NUMBER: ME 433 Fluidics Hydraulic circuit Course teacher Prof. Mahbubur Razzaque 1 FAIL-SAFE CIRCUITS Fail-safe circuits are those designed to prevent injury to the operator or damage to equipment.

More information

Eaton Electronic Proportional (EP) Control for Medium Duty Piston Pumps

Eaton Electronic Proportional (EP) Control for Medium Duty Piston Pumps Eaton Electronic Proportional (EP) Control for Medium Duty 72400 Piston Pumps Table of Contents Introduction....................................................... 3 Identification of Components.........................................

More information

Technical Information for PVX Series Pumps

Technical Information for PVX Series Pumps Technical Information for PVX Series Pumps TM 604 PROGRESS DRIVE, HARTLAND, WI 53029 USA Phone: (262) 367-4299 FAX: (262) 367-5645 URL: www.hartmanncontrols.com E-mail: sales@hartmanncontrols.com PVX pumps

More information

HELPING HAND EXPERT 2000

HELPING HAND EXPERT 2000 HELPING HAND Release date: January 2005 Part #47916 rev. 0 2-2 2-3 HELPING HAND AUTOMATED ARM Table of contents 2.0 HELPING HAND MAINTENANCE... 2-5 2.1 HYDRAULIC SYSTEM MAINTENANCE... 2-5 2.1.1 HYDRAULIC

More information

VARIABLE PUMPS FOR CLOSED LOOP OPERATION type HV-02

VARIABLE PUMPS FOR CLOSED LOOP OPERATION type HV-02 Design characteristics 1-control device modular design, precise and load-independent 2-swash plate hydrostatic bearing 3-piston-slipper assembly 21 swash angle 4-housing monoshell for high rigidity 5-valve

More information

Lecture 6. Systems review exercise To be posted this afternoon Due in class (10/23/15)

Lecture 6. Systems review exercise To be posted this afternoon Due in class (10/23/15) 153 Systems review exercise To be posted this afternoon Due in class (10/23/15) Lecture 6 Coming week: Lab 13: Hydraulic Power Steering Lab 14: Integrated Lab (Hydraulic test bench) Topics today: 2 min

More information

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring. Test 1 1. Which statement is True? A. Pneumatic systems are more suitable than hydraulic systems to drive powerful machines. B. Mechanical systems transfer energy for longer distances than hydraulic systems.

More information

T550 COMPACT TRACK LOADER SPECIFICATIONS

T550 COMPACT TRACK LOADER SPECIFICATIONS T550 COMPACT TRACK LOADER SPECIFICATIONS Loader Dimensions Dimensions are given for loader equipped with standard tracks and 68 in. Construction and Industrial bucket and may vary with other bucket types.

More information

Electronic Proportional (EP) Control for Heavy Duty Series 0/1 Piston Pumps Model 33 Model 39 Model 46. Model 54 Model 64 Model 76

Electronic Proportional (EP) Control for Heavy Duty Series 0/1 Piston Pumps Model 33 Model 39 Model 46. Model 54 Model 64 Model 76 Electronic Proportional (EP) Control for Heavy Duty Series 0/1 Piston Pumps Model 33 Model 39 Model 46 Model 54 Model 64 Model 76 Table of Contents Introduction.......................................................

More information

PUmP REfEREncE guide Bulletin E

PUmP REfEREncE guide Bulletin E Pump reference guide Bulletin 40000-E Table of Contents PVWJ Pumps page 3 PVG Pumps page 4 PVM Pumps page 5 PVWW Pumps page 6 PVV Pumps page 7 Table of Contents PVK Pumps page 8 PVWC Pumps page 9 PFBA

More information

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery Table 6-1. and solutions with pump operations No Fluid Delivery Fluid level in the reservoir is low. Oil intake pipe or inlet filter is plugged. Air leak in the inlet line prevents priming or causes noise

More information

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces: Axial piston variable pump A4VG Series 32 Europe RE-E 92003 Edition: 04.2016 Replaces: 06.2012 High-pressure pump for applications in a closed circuit Size 28 to 125 Nominal pressure 400 bar Maximum pressure

More information

Operation & Service Manual

Operation & Service Manual Operation & Service Manual Model: 5010 Hydraulic Power Unit 05/2004 - Rev. 01 Includes Illustrated Parts Lists 1740 Eber Rd Tronair, Inc. Phone: (419) 866-6301 Holland, OH 43528-9794 www.tronair.com 800-426-6301

More information

Eaton Fixed Displacement HHD Motor and Variable ACA Pump

Eaton Fixed Displacement HHD Motor and Variable ACA Pump Eaton Fixed Displacement HHD Motor and Variable ACA Pump www.hydpump.com Pump Eaton 3923 4623 5423 6423 7620 7640 Motor Eaton 3933 4633 5433 6433 7630 Eaton ACA Pump Technical Data Table of values (theoretical

More information

BTP Hydraulics Hydraulics Circuits, Components, Schematics, Hydrostatic Drives and Test Equipment

BTP Hydraulics  Hydraulics Circuits, Components, Schematics, Hydrostatic Drives and Test Equipment BTP Hydraulics www.iranfluidpower.com Hydraulics Circuits, Components, Schematics, Hydrostatic Drives and Test Equipment PART NO. 09169SL This page is intentionally blank. Hydraulic Systems 1 Table of

More information

CH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G

CH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G Content : 4.1 Hydraulic and Pneumatic actuators. 10 Marks Hydraulic Actuators - Hydraulic cylinders (single, double acting and telescopic) construction and working, Hydraulic motors (gear and piston type)

More information

Variable Displacement Open Loop Circuit Axial Piston Pumps. V Series

Variable Displacement Open Loop Circuit Axial Piston Pumps. V Series HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Via M. L. King, 6-41122 MODENA (ITALY) Tel: +39 59 415 711 Fax: +39 59 415 729 / 59 415 73 INTERNET: http://www.hansatmp.it E-MAIL:

More information

3. At sea level, the atmosphere exerts psi of pressure on everything.

3. At sea level, the atmosphere exerts psi of pressure on everything. 41 Chapter Gasoline Injection Fundamentals Name Instructor Date Score Objective: After studying this chapter, you will be able to explain the construction, operation, and classifications of modern gasoline

More information

Variable Displacement Pump A4VG for closed circuits

Variable Displacement Pump A4VG for closed circuits RE 92 003/05.99 RE 92 003/05.99 replaces: 02.98 Variable Displacement Pump A4VG for closed circuits Sizes 28...250 Series 3 Nominal pressure 400 bar Peak pressure 450 bar A4VG...EP Index Features 1 Ordering

More information

MP1 Axial Piston Pumps Size 28/32, 38/45

MP1 Axial Piston Pumps Size 28/32, 38/45 Technical Information MP1 Axial Piston Pumps Size 28/32, 38/45 www.danfoss.com Revision history Table of revisions Date Changed Rev May 2018 add 14 tooth shaft, minor edits 0106 March 2018 update MDC control

More information

Module 5: Valves. CDX Diesel Hydraulics. Terms and Definitions. Categories of Valves. Types of Pressure Control Valves

Module 5: Valves. CDX Diesel Hydraulics. Terms and Definitions. Categories of Valves. Types of Pressure Control Valves Terms and Definitions Categories of Valves Types of Pressure Control Valves Types and Operation of Pressure Relief Valves Operation of an Unloading Valve Operation of a Sequencing Valve Operation of a

More information

LECTURE 27 SERVO VALVES FREQUENTLY ASKED QUESTIONS

LECTURE 27 SERVO VALVES FREQUENTLY ASKED QUESTIONS LECTURE 27 SERVO VALVES FREQUENTLY ASKED QUESTIONS 1. Define a servo valve Servo valve is a programmable orifice. Servo valve is an automatic device for controlling large amount of power by means of very

More information

CS-SCB Sander Control Block Manual

CS-SCB Sander Control Block Manual Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service CS-SCB Sander Control Block Manual The Drive & Control Company Copyright 1996 Bosch Rexroth Canada All

More information

speed hydraulic motors. Permission granted to reproduce for educational use only. Contrast the operation of fixed- and variable-

speed hydraulic motors. Permission granted to reproduce for educational use only. Contrast the operation of fixed- and variable- Chapter 9 Actuators Workhorses of the System 1 Objectives Describe the construction and operation of basic hydraulic cylinders, limited-rotation actuators, and motors. Compare the design and operation

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : TAP- IN KIT 5100-5151 BAYNE MACHINE WORKS, INC. PHONE: (864) 288-3877 910 FORK SHOALS ROAD TOLL FREE: (800) 535-2671 GREENVILLE S.C., 29605 FAX:

More information

Control Pacs. Position Controlled Power Actuator (Westinghouse) Control Pac is short for Position-Controlled

Control Pacs. Position Controlled Power Actuator (Westinghouse) Control Pac is short for Position-Controlled Control Pacs Position Controlled Power Actuator (Westinghouse) Control Pac is short for Position-Controlled Power Actuator. The position controlled power actuator provides the power to open and close the

More information

Jet Pipe Servovalves

Jet Pipe Servovalves Servovalves OVERVIEW Section Page MOOG JET PIPE SERVOVALVES Overview 2 3 Technical Data 4 6 Electrical Characteristics 7 Performance Specs. 8-15 Installation Procedures 16-17 Ordering Information 18-19

More information

System Background and Operation

System Background and Operation Pty Limited 1/48 Racecourse Road RUTHERFORD NSW 2320 Telephone: (02) 4932 0111 Facsimile: (02) 4932 0222 E-mail:hyden@hydeneng.com.au ABN: 17 129 010 902 ENVIROSPRAY Manual Manual Number: 06500976A Manual

More information

Axial Piston Closed Circuit Pumps Series 42

Axial Piston Closed Circuit Pumps Series 42 MAKING MODERN LIVING POSSIBLE Service Manual Axial Piston Closed Circuit Pumps Series 42 powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev July 2015 Danfoss layout 0300 Nov

More information

3/3-Way-Proportional Valve

3/3-Way-Proportional Valve 3/3-Way-Proportional Valve Content Page General Description 1 Design 2 Function 2 Technical Data 3 Options 4 Dimensions 5 Accessories 6 Flow Curves 7 General Description This proportional valve in combination

More information

Operation & Service Manual

Operation & Service Manual Operation & Service Manual Model: 5B20 Hydraulic Power Unit 07/2011 - Rev. 06 Includes Illustrated Parts Lists 1740 Eber Rd Tronair, Inc. Phone: (419) 866-6301 Holland, OH 43528-9794 www.tronair.com 800-426-6301

More information

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually. Air/Oil Systems: A lubrication system in which small measured quantities of oil are introduced into an air/oil mixing device which is connected to a lube line that terminates at a bearing, or other lubrication

More information

REPAIR MANUAL AFX8010

REPAIR MANUAL AFX8010 REPAIR MANUAL AFX 1 27/05/2004 Contents INTRODUCTION DISTRIBUTION SYSTEMS POWER PRODUCTION POWER TRAIN TRAVELLING BODY AND STRUCTURE TOOL POSITIONING CROP PROCESSING A B C D E G K AFX 1 27/05/2004 INTRODUCTION

More information

Flow direction is reversed by tilting the swash plate to the opposite side of the neutral or zero displacement position.

Flow direction is reversed by tilting the swash plate to the opposite side of the neutral or zero displacement position. General Description Axial piston variable displacement pumps, Series 20, are of swash plates construction with variable flow capability suitable for hydrostatic transmission with closed loop circuit. The

More information

CONTROL SOLUTIONS FORKLIFT TRUCKS FORKLIFT TRUCKS

CONTROL SOLUTIONS FORKLIFT TRUCKS FORKLIFT TRUCKS CONTROL SOLUTIONS FORKLIFT TRUCKS FORKLIFT TRUCKS For over 50 years, HUSCO International has been designing and producing some of the most important custom hydraulic and electrohydraulic products in the

More information

MP1 Axial Piston Pumps Size 28/32, 38/45

MP1 Axial Piston Pumps Size 28/32, 38/45 Technical Information MP1 Axial Piston Pumps Size 28/32, 38/45 powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev August 2016 First Edition 0101 2 Danfoss August 2016 BC00000352en-US

More information

Electronic Proportional (EP) Control for Medium Duty Piston Pumps

Electronic Proportional (EP) Control for Medium Duty Piston Pumps Electronic Proportional (EP) Control for Medium Duty 72400 Piston Pumps EP Control for Medium Duty 72400 Piston Pumps Table of Contents Introduction........................................................................

More information

Standard Power Units Start-Up and Maintenance

Standard Power Units Start-Up and Maintenance Standard Power Units Start-Up and Maintenance Value-Pak System-Pak System Pak-Plus Low-Pak System-Center System-L System-Overhead Table of Contents General Information....................................................................

More information

555C WHEEL LOADER. Bucket Capacity 4.2 m 3 to 8.4 m 3 (5.5 yd 3 to 11.0 yd 3 ) Net Horsepower 238 kw (319 hp) Operating Weight kg (63,753 lb)

555C WHEEL LOADER. Bucket Capacity 4.2 m 3 to 8.4 m 3 (5.5 yd 3 to 11.0 yd 3 ) Net Horsepower 238 kw (319 hp) Operating Weight kg (63,753 lb) 555C WHEEL LOADER Net Horsepower 238 kw (319 hp) Bucket Capacity 4.2 m 3 to 8.4 m 3 (5.5 yd 3 to 11.0 yd 3 ) Operating Weight 28918 kg (63,753 lb) World class loader meeting high production requirements