Filtromat OF5LxxPxMxB

Size: px
Start display at page:

Download "Filtromat OF5LxxPxMxB"

Transcription

1 Filtromat Operating and Maintenance Instructions English (translation of original instructions) Document No.: a

2 Trademarks Trademarks The trademarks of other companies designate the products of those companies exclusively. Copyright 2011 by HYDAC Filter Systems GmbH all rights reserved All rights reserved. This manual may not be reproduced in part or whole without the express written consent of HYDAC FILTER SYSTEMS GMBH. Contraventions are liable to compensation. Exclusion of liability We have made every endeavor to ensure the accuracy of the contents of this document. However, errors cannot be ruled out. Consequently, we accept no liability for such errors as may exist nor for any damage or loss whatsoever which may arise as a result of such errors. The content of the manual is checked regularly. Any corrections required will be incorporated in future editions. We welcome any suggestions for improvements. All details are subject to technical modifications. All content of this manual is subject to revision without notice. HYDAC FILTER SYSTEMS GMBH Postfach Sulzbach / Saar Germany Documentation Representative Mr. Günter Harge c/o HYDAC International GmbH, Industriegebiet, Sulzbach / Saar Telephone: ++49 (0) Fax: ++49 (0) guenter.harge@hydac.com HYDAC FILTER SYSTEMS GMBH en(us) Page 2/36

3 Contents Contents Trademarks...2 Documentation Representative...2 Contents...3 Preface...5 Customer Service...6 Modifications to the Product...6 Warranty...6 Using the Documentation...7 Safety information and instructions...8 Obligations and Liability...8 Explanation of Symbols and Warnings, etc....9 Proper/Designated Use...9 Improper Use...10 Informal Safety Precautions...10 Structural modifications to the unit...10 Training of personnel...11 Electrical hazards...11 Transporting the OF Storing the OF Checking the scope of delivery...13 OF5 Features...14 Restrictions Pertaining...14 OF5 Lxx...14 OF5 dimensions...15 OF5 components/dimensions...16 Hydraulic diagram...17 Preparing the OF5 for operation...18 Inserting the filter element...18 Hanging / connecting the suction hose...18 Hanging / connecting the pressure hose...18 Electrical connection of the OF Switching on the OF Performing Maintenance...21 Cleaningthe suction strainer...22 HYDAC FILTER SYSTEMS GMBH en(us) Page 3/36

4 Contents Changing the filter element...23 Errors and troubleshooting...29 Spare parts...30 filter...31 Disposing of the OF Technical Data...33 Model Code...34 EC declaration of conformity...35 HYDAC FILTER SYSTEMS GMBH en(us) Page 4/36

5 Preface Preface For you as the owner of a product manufactured by us, we have produced this manual, comprising the most important instructions for its operation and maintenance. It will acquaint you with the product and assist you in obtaining maximum benefit in the applications for which it is designed. Keep the manual in the vicinity of the device for immediate reference. Note that the information on the unit's engineering contained in the documentation was that available at the time of publication.there may be deviations in technical details, figures, and dimensions as a result. If you discover errors while reading the documentation or have additional suggestions or notes, contact us at: HYDAC FILTER SYSTEMS GMBH Technische Dokumentation Postfach Sulzbach / Saar Germany The editorial department looks forward to receiving your input. Our motto: Putting experience into practice HYDAC FILTER SYSTEMS GMBH en(us) Page 5/36

6 Preface Customer Service Contact our technical sales department if you have any questions on our product. When contacting us, please always include the model/type designation, serial no. and part-no. of the product: Fax: ++49 (0) 6897 / filtersystems@hydac.com Modifications to the Product We would like to point out that changes to the product (e.g. purchasing options, etc.) may result in the information in the operating instructions no longer being completely accurate or sufficient. When making modifications or performing repair work to components affecting the safety of the product, the product may not be put back into operation until it has been examined and released by a HYDAC representative. Please notify us immediately of any modifications made to the product whether by you or a third party. Warranty For the warranty provided by us, please refer to the General Terms of Sale and Delivery of HYDAC FILTER SYSTEMS GmbH. Refer to these at General terms and conditions. HYDAC FILTER SYSTEMS GMBH en(us) Page 6/36

7 Preface Using the Documentation Please note that the method described above of locating specific information does not release you from your responsibility for carefully reading the entire manual prior to starting the unit up for the first time and carefully rereading the manual at regular intervals later on. WHAT do I want to know? I determine which topic I am looking for. WHERE can I find the information I m looking for? The documentation has a table of contents at the beginning. There, I select the chapter I'm looking for and the corresponding page number. Chapter description Page number Edition date Documentation No. with Index / File name Document language The documentation number with its index enables you to order another copy of the operating and maintenance instructions. The index is incremented every time the manual is revised or changed. HYDAC FILTER SYSTEMS GMBH en(us) Page 7/36

8 Safety information and instructions Safety information and instructions These operating instructions contain the most important information for operating the unit in a proper, safe manner. Obligations and Liability The basic prerequisite for the safe and proper handling and operation of the unit is knowledge of the basic safety instructions and safety regulations. These operating instructions in general, and the safety instructions in particular, are to be adhered by all those who work with the unit. Adherence is to be maintained to pertinent accident prevention regulations applicable at the site where the product is used. The safety instructions listed here are restricted to use of the unit. The OF has been designed and constructed in accordance with the current state of the art and recognized safety regulations. Nevertheless, hazards may be posed to the life and limb of the individual using the product or to third parties. Risk of damage may be posed to the product or other equipment and property. Ensure that the unit is used: Solely for its designated use only when in a safe, perfect condition Immediately remedy any malfunctions that might impair safety. Our General Terms and Conditions apply. They are made available to the owner upon concluding purchase of the unit at the latest. Any and all warranty and liability claims for personal injuries and damage to property shall be excluded in the event they are attributable to one or more of the following causes: improper use of the unit or use deviating from its designated use improper assembly/installation, start up, operation and maintenance of the unit operating the unit when the system equipment or systems are defective modifications to the unit made by the user or purchaser improperly performed repair work HYDAC FILTER SYSTEMS GMBH en(us) Page 8/36

9 Safety information and instructions Explanation of Symbols and Warnings, etc. The following designations and symbols are used in this manual to designate hazards, etc.: DANGER WARNING CAUTION NOTICE DANGER denotes situations which can lead to death if safety precautions are not observed. WARNING denotes situations which can lead to death if safety precautions are not observed. CAUTION denotes situations which can lead to severe injuries if safety precautions are not observed. NOTICE denotes situations which can lead to property damage if safety precautions are not observed. Proper/Designated Use The unit is a mobile filter unit used for simultaneously circulating and filtering oil. Any other use shall be deemed to be improper and not in keeping with the product's designated use. The manufacturer will not assume liability for any damage resulting from such use. Proper or designated use of the product extends to the following: Maintaining adherence to all the instructions contained herein. Performing requisite inspection and maintenance work. HYDAC FILTER SYSTEMS GMBH en(us) Page 9/36

10 Safety information and instructions Improper Use Any use other than described above is prohibited. Improper use may result in hazards to life and limb. Example of improper use: Commissioning without a suction strainer Operation with non-approved fluids Informal Safety Precautions Always keep the operating instructions in the vicinity of the unit. Apart from the operating instructions, any and all general and local regulations pertaining to accident prevention and environmental protection are to be made available and observance is to be maintained to them. All safety guidelines and hazard warnings on the machine must be maintained in legible condition and replaced as required. Structural modifications to the unit Do not make any modifications (design modifications, extensions) to the OF without the approval of the manufacturer. Immediately replace any unit components which are not in perfect condition. Only use original (OEM) spare parts and consumables. When using non-oem components it cannot be ensured that they have been designed and manufactured so as to comply with loading and safety requirements. HYDAC FILTER SYSTEMS GMBH en(us) Page 10/36

11 Safety information and instructions Training of personnel The OF may only be operated by properly trained and instructed personnel. The areas of responsibility of your staff must be established in a clear-cut manner. Staff undergoing training may not use the OF unless supervised by an experienced staff member. Individuals Instructed individuals Personnel with technical training/ engineering background Electricians Supervisors with required expertise Activity Packing / transportation X X X Commissioning X X X Operation X X X X Troubleshooting/ locating the source of malfunction X X X Troubleshooting, mechanical problem X X Remedying of electrical faults X X maintenance X X X X Servicing X Decommissioning / Storage X X X X Electrical hazards DANGER Electric shock Danger of fatal injury Pull power plug before performing any work. HYDAC FILTER SYSTEMS GMBH en(us) Page 11/36

12 Transporting the OF5 Transporting the OF5 Transport the unit upright on the built-in wheels or by rolling it. Storing the OF5 Remove the filter element and drain the unit completely before putting it into storage. Pull out the power plug to the unit and wind up the power cord. Wind up the suction and pressure hoses and secure them to the unit. Store the unit upright in a clean, dry place. HYDAC FILTER SYSTEMS GMBH en(us) Page 12/36

13 Checking the scope of delivery Checking the scope of delivery The filtration unit is supplied ready for connection and immediate operation with hoses and a mains connection. Check the unit for damage upon delivery. A unit may only be put into operation if it shows no signs of damage. Report any damage in transit to the forwarding agent or responsible party. The following items are supplied: Item Qty. Designation 1 1 OF5 with power cable, suction hose and pressure hose - 1 filter element - 1 Operating and Maintenance Instructions 1 HYDAC FILTER SYSTEMS GMBH en(us) Page 13/36

14 OF5 Features OF5 Features The mobile filtration unit OF5 is used for filtered filling, offline filtration. Restrictions Pertaining NOTICE Impermissible operating media The unit will be damaged The unit is only to be used with mineral oils or mineral oil-based raffinates. OF5 Lxx HYDAC FILTER SYSTEMS GMBH en(us) Page 14/36

15 OF5 dimensions OF5 dimensions All dimensions in mm. HYDAC FILTER SYSTEMS GMBH en(us) Page 15/36

16 OF5 components/dimensions OF5 components/dimensions Item Designation 1 Handle 2 On/off switch with motor protection 3 Power cables 4 Electric motor with gear pump 5 Floor plate with oil pan 7 Pressure hose 8 Suction hose 9 Quick coupling HYDAC FILTER SYSTEMS GMBH en(us) Page 16/36

17 Hydraulic diagram Hydraulic diagram CI = contamination indication HYDAC FILTER SYSTEMS GMBH en(us) Page 17/36

18 Preparing the OF5 for operation Preparing the OF5 for operation Consult and observe the following chapter in order to prepare the unit for operation. Inserting the filter element The unit has no filter element installed upon delivery from the factory. Prior to start up, check to see whether a filter element is contained in the filter housing. Information on changing a filter element can be found on page 23. Hanging / connecting the suction hose NOTICE Severe contamination The unit will be destroyed Do not prime directly at the bottom of the tank (in the sump). The greatest contamination is found on the bottom of the tank. All impurities and other particles are deposited on the bottom of the tank. Pull the suction hose with lance out of the mounting in the floor plate. Put the suction hose with lance, without tension and or twist, into the appropriate container and secure it. Hanging / connecting the pressure hose Pull out the pressure hose with lance from the mounting in the floor plate and insert it in the appropriate container. Put the pressure hose with lance, without tension and or twist, into the appropriate container and secure it. To prevent air from entering the medium, make sure that the pressure hose with lance is always below the oil level in operation. HYDAC FILTER SYSTEMS GMBH en(us) Page 18/36

19 Preparing the OF5 for operation Electrical connection of the OF5 Check or compare the local mains voltage and frequency specifications with the specifications on the type label of the unit. Plug the power plug into a suitable power outlet. The unit has a motor protection switch in the on / off switch. If the nominal current is exceeded, the motor protection switch trips. HYDAC FILTER SYSTEMS GMBH en(us) Page 19/36

20 Switching on the OF 5 Switching on the OF 5 After switching on the OF5, monitor the suction action via the transparent suction hose. If the unit is not feeding medium after several minutes of operation, the pump must be pre-filled. Switch the motor off and fill the pump via the suction hose. It is not necessary to bleed the filter housing. Pay particular attention to the clogging indicator during operation. As soon as the clogging indicator enters the red zone, the filter element must be changed immediately. The pressure relief valve in the pump returns the medium to the suction side if the maximum operating pressure is exceeded. The motor protection switch contained in the main switch permanently monitors the nominal current and switches the unit off in case of overload. HYDAC FILTER SYSTEMS GMBH en(us) Page 20/36

21 Performing Maintenance Performing Maintenance WARNING The unit is pressurized Danger of bodily injury Depressurize the system before performing any work on it. DANGER Electric shock Danger of fatal injury Disconnect the power plug before performing any work on the unit. HYDAC FILTER SYSTEMS GMBH en(us) Page 21/36

22 Cleaningthe suction strainer Cleaningthe suction strainer NOTICE Operation without a suction strainer The unit will be destroyed Never operate the filtration unit without a suction strainer. Clean the suction strainer regularly. To protect the pump from coarse contamination or foreign bodies, a suction strainer is installed at the inlet of the pump. Clean the suction strainer regularly and check it immediately in the event of insufficient suction or delivery action. Item x Description Suction strainer HYDAC FILTER SYSTEMS GMBH en(us) Page 22/36

23 Changing the filter element Changing the filter element The red/green optical differential pressure gauge, shows the red area from a differential pressure of 5 bar. Change the filter element as soon as the differential pressure gauge is in the red area. HYDAC FILTER SYSTEMS GMBH en(us) Page 23/36

24 Changing the filter element To change the filter, proceed as follows: 1. Switch the unit off. 2. Empty the filter housing through the drain plug (1) in the filter bowl using an Allen wrench, size 10. Catch the residual oil (~ 1.5 liters) in a suitable container (2). Screw in the drain plug (1) counterclockwise again and tighten it. HYDAC FILTER SYSTEMS GMBH en(us) Page 24/36

25 Changing the filter element 3. (1) Unscrew the filter bowl using an open-jaw wrench, opening width 36 mm in a counterclockwise direction. (2) Now pull the filter element downwards carefully out of the bowl. Dispose of the used filter element in an environmentally correct manner. 4. Clean: the inside of the filter bowl of coarse dirt the sealing surfaces on the filter head and cover. Check the O-ring on the filter bowl for damage. Replace it if necessary. HYDAC FILTER SYSTEMS GMBH en(us) Page 25/36

26 Changing the filter element 5. Moisten the O-ring on the filter bowl lightly with operating medium. 6. Moisten the O-ring on the filter element lightly with operating medium. 8. Press the new filter element up into the filter mount by turning it slightly. Do not use excessive force or a hammer, etc. HYDAC FILTER SYSTEMS GMBH en(us) Page 26/36

27 Changing the filter element 10. Manually turn the filter bowl clockwise from below into the filter head. 11. Pull in the filter bowl as far as it will g. HYDAC FILTER SYSTEMS GMBH en(us) Page 27/36

28 Changing the filter element 12. Unscrew the filter bowl by 90 in clockwise direction. 13. Switch the unit on. I OFF ON 14. Check the unit for any leaks. 15. The unit is ready for use. HYDAC FILTER SYSTEMS GMBH en(us) Page 28/36

29 Errors and troubleshooting Errors and troubleshooting Error Cause(s) Remedy Differential pressure > 5 bar No flow No function The fluid is heavily contaminated. The contamination retention capacity of the filter element has been reached. The viscosity of the fluid is too high. The suction hose is positioned above the fluid. No electrical connection. No voltage available. Replace the filter element. Replace the filter element. Warm the fluid. Sufficiently immerse the suction hose in the medium. Check the electrical connection; plug, cable and socket. HYDAC FILTER SYSTEMS GMBH en(us) Page 29/36

30 Spare parts Spare parts Description p/no. Suction strainer 320 µm filter element 0330 D 003 BN4HC 3 µm NBR filter element 0330 D 005 BN4HC 5 µm NBR filter element 0330 D 010 BN4HC 10 µm NBR filter element 0330 D 020 BN4HC 20 µm NBR Gear pump assembly Pressure hose L= 5 m Pressure hose L= 15 m Suction hose L= 2.3 m Hose between pump and filter housing L= 0.3 m Differential pressure gauge Green/red HYDAC FILTER SYSTEMS GMBH en(us) Page 30/36

31 Spare parts filter HYDAC FILTER SYSTEMS GMBH en(us) Page 31/36

32 Disposing of the OF5 Item Designation p/no. 1.1 filter element 0330 D 005 BN4HC O-ring 48 x contamination indication VM5B profile seal ring O-ring 15 x 1, x Repair kit, consisting of item O-ring 48 x O-ring 117 x Support ring DF profile seal ring VM O-ring 15 x 1, Oil drain plug G1/ Disposing of the OF5 When decommissioning and/or disposing of the unit, observe all local guidelines and regulations pertaining to occupational safety and environmental protection. This applies in particular to the oil in the unit, components covered with oil and electronic components. After disassembling the unit and separating the various materials, reuse them or dispose of them properly in accordance with local regulations. HYDAC FILTER SYSTEMS GMBH en(us) Page 32/36

33 Technical Data Technical Data Supply voltage Power consumption Maximum flow rate Pump types Operating Pressure Permissible suction pressure at suction port Viscosity range 1x 230V, 60 Hz, 1 Ph 0.43 kw 15 l/min Gear pump 8 bar maximum bar mm²/s Fluid temperature 0 80 C Ambient temperature range C Seals NBR IP Class IP 54 Length of electronic cable Length of suction / pressure hose Hose connections Weight Filter element type 22 m 2,3 / m Suction hose NW20 with lance Pressure hose NW 19 with lance ~ 75 kg Betamicron BN4HC Filter element size LF 330 contamination indication Differential pressure gauge 5 bar (VM5B1) HYDAC FILTER SYSTEMS GMBH en(us) Page 33/36

34 Model Code Model Code Basic type OF 5 Version L = Mobile without switchover Type code xx = Special model Sealing material P = NBR (Perbunan) Motor-pump group x = 15 l/min / to max mm²/s Electromotor voltage M = 230 V / 60 Hz (1 Ph + PE) Filter size x = Filter size LF 330 Filter material b = Betamicron BN4HC Filtration rating 03 = 3 µm BN4HC 05 = 5 µm BN4HC 10 = 10 µm BN4HC 20 = 20 µm BN4HC contamination indication b = Differential pressure gauge standard OF5 L xx P x M x b 05 b HYDAC FILTER SYSTEMS GMBH en(us) Page 34/36

35 EC declaration of conformity EC declaration of conformity HYDAC FILTER SYSTEMS GMBH Postfach Sulzbach / Saar Germany Industriegebiet Sulzbach / Saar Germany Telefon: ++49 (0) Internet: EC declaration of conformity FS / 37 / 09 No. We hereby declare that the following designated product, on the basis of its design and construction, and in the version which we have brought to market, corresponds to the fundamental safety and health requirements contained in the standards listed below. Any modification of this product that is not coordinated with us in writing will cause this declaration to lose its validity. Designation Filtration Unit Type OF 5 mobile series p/no. - Serial no. - EU Machinery Directive 2006/42/EC EU Electrical Equipment Regulations 2006/95/EC EMC Guideline 2004/108/EC Safety of machinery and devices EN / Dr. Andreas Schunk Date Name (CE official) Executive director: Documentation Representative: Mathias Dieter, Dipl.Kfm. Wolfgang Haering Mr. Günter Harge Registered seat of company: Sulzbach / Saar - Germany c/o HYDAC International GmbH, Industriegebiet, Sulzbach / Saar Registry Court: Saarbrücken, HRB Phone: ++49 (0) Value added tax identification number: DE Fax: ++49 (0) Tax number: 040/110/ guenter.harge@hydac.com Page 1 / 1 HYDAC FILTER SYSTEMS GMBH en(us) Page 35/36

36 HYDAC FILTER SYSTEMS GMBH Industriegebiet Postfach Sulzbach/Saar Sulzbach/Saar Germany Germany Phone: +49 (0) Central Fax: +49 (0) Technical Department Fax: +49 (0) Sales Department Internet:

FMM-P-L. FluidMonitoring Module. Installation and Maintenance Instructions. English (translation of original instructions) Document No.

FMM-P-L. FluidMonitoring Module. Installation and Maintenance Instructions. English (translation of original instructions) Document No. FMM-P-L Installation and Maintenance Instructions English (translation of original instructions) Document No.: 3493215 Trademarks Trademarks The trademarks of other companies are exclusively used for the

More information

MRF D3 MultiRheo Filter

MRF D3 MultiRheo Filter MRF D3 MultiRheo Filter Operating and Maintenance Instructions English (translation of original instructions) Document no.: 3217120b Imprint Imprint Publisher and responsible for the content: HYDAC FILTER

More information

CSM 1000 Series. ContaminationSensor Module. Operating and Maintenance Instructions. English (translation of original instructions)

CSM 1000 Series. ContaminationSensor Module. Operating and Maintenance Instructions. English (translation of original instructions) ContaminationSensor Module Operating and Maintenance Instructions English (translation of original instructions) Documentation no.: 3265074g (from series no. 4555/2009) Trademarks Trademarks The trademarks

More information

WBF /-T003 bar magnet insert for Wombat filter housing

WBF /-T003 bar magnet insert for Wombat filter housing WBF /-T003 bar magnet insert for Wombat filter housing Installation and Maintenance Instructions English (translation of original instructions) Document No.: 4332365 Imprint Imprint Manufacturer / publisher

More information

Court of Registration: Saarbrücken, HRB Haering

Court of Registration: Saarbrücken, HRB Haering LVU-CD-10 LowViscosity Unit CoaleserDiesel with control type: Eco Operating and Maintenance Instructions English (translation of original instructions) Document No.: 4067271 Keep for future reference.

More information

LVU-CD-10 LowViscosity Unit CoaleserDiesel

LVU-CD-10 LowViscosity Unit CoaleserDiesel LVU-CD-10 LowViscosity Unit CoaleserDiesel with control type: Standard or Premium Operating and Maintenance Instructions English (translation of original instructions) (Valid Series no. 0002S03302K0000010)

More information

LVU-CD-40 LowViscosity Unit CoalescerDiesel

LVU-CD-40 LowViscosity Unit CoalescerDiesel LVU-CD-40 LowViscosity Unit CoalescerDiesel Operating and Maintenance Instructions English (translation of original instructions) Document No.: 4035823a Keep for future reference. Imprint Imprint Publisher

More information

VarnishElimination Unit- Filtration VEU-F-60/1-x-C

VarnishElimination Unit- Filtration VEU-F-60/1-x-C VarnishElimination Unit- Filtration VEU-F-60/1-x-C Operating and Maintenance Instructions English (translation of original instructions) Keep for future reference. Document No.: 4104528 Imprint Imprint

More information

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference! Tension Meter FT Series S C H M I D T c o n t r o l i n s t r u m e n t s Edition FT 03.E Model FT Instruction Manual Valid as of: 01.09.2011 Please keep the manual for future reference! Contents 1 Warranty

More information

Operating instructions

Operating instructions Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future

More information

Spare Parts List Return line filter RF

Spare Parts List Return line filter RF Spare Parts List Return line filter up to 15000 l/min, up to 25 bar 30 60 110 160 240 330 450 580 660 950 1300 2500 4000 5200 6500-7800 15000 1. MAINTENANCE 1.1 GENERAL Please follow the maintenance instructions!

More information

Spare Parts List Filter NFD Change-Over Version

Spare Parts List Filter NFD Change-Over Version Spare Parts List Filter Change-Over Version up to 1600 l/min, up to 5 bar 1340 640 540 7840 10440 1. MAINTENANCE GENERAL Please follow the maintenance instructions! 1. INSTALLATION Before fitting the filter

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

original operating manual Operating manual Translation of the Item-No.: ,

original operating manual Operating manual Translation of the Item-No.: , Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty

More information

Spare parts list Return line filter RFM with 2-hole attachment

Spare parts list Return line filter RFM with 2-hole attachment Spare parts list Return line filter with 2-hole attachment Tank-top mounted version: up to 200 l/min, up to 10 bar 75 90 150 165 185 195 1. MAINTENANCE 1.1 GENERAL Please follow the maintenance instructions!

More information

OFX7 Operating Maintenance and Troubleshooting Manual L-4219

OFX7 Operating Maintenance and Troubleshooting Manual L-4219 OFX7 Operating Maintenance and Troubleshooting Manual L-4219 L-2999 Created 9.2012 User Manual OFX7 L-4219 - Table of Contents - Preface. 4 Customer Service. 4 Modifications to the Product 4 Warranty.

More information

Oil-free piston compressors KK and piston vacuum pumps KV

Oil-free piston compressors KK and piston vacuum pumps KV Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10. 27 Elster GmbH Edition.7 Translation from the German 344297 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve Contents Solenoid valve... Contents... Safety....

More information

Spare parts list Inline filter FLND switchable

Spare parts list Inline filter FLND switchable Spare parts list Inline filter switchable to DIN 24550*, up to 400 l/min, up to 63 bar *Filters and fi lter elements also available in HYDAC dimensions 60 110 140 40 63 100 160 250 400 1. MAINTENANCE 1.1

More information

RFN Series Service and Parts

RFN Series Service and Parts Filters RFN Series Service and Parts up to 166 gpm (630 l/min), up to 145 psi (10 bar) 1. Maintenance 1.1 General Please follow the maintenance instructions. 1.2 Installation Before installing the filter

More information

Installation manual portable distributors

Installation manual portable distributors EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...

More information

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15 17 Elster GmbH Edition 1.17 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas

More information

RESOL SBS 1000 * * Connection Operation

RESOL SBS 1000 * * Connection Operation RESOL SBS 1000 Connection Operation FlowCon SBS 1000 A www.resol.de *48003820* 48003820 Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from this

More information

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN 24550 up to 630 l/min, up to 10 bar RFN 40 RFN 63 RFN 100 RFN 160 RFN 250 RFN 400 RFN 630 1. MAINTENANCE 1.1 GENERAL Please follow

More information

Application cup for OptiFlex 2 GM03 manual powder gun

Application cup for OptiFlex 2 GM03 manual powder gun En Operating instructions and spare parts list Application cup for OptiFlex 2 GM03 manual powder gun Translation of the original operating instructions Documentation OptiFlex GM03 application cup Copyright

More information

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z INSTRUCTION MANUAL I/P Converter DSG BXXY3Z DSG BXXY4Z Revision 2.0 3.626 016136 en Page 1/15 Should you have any questions concerning the I/P converter, please contact the Service Department of the Product

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual SBS 2000 Filling and flushing station Manual for the specialised craftsman Connection Operation Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from

More information

Filters. RFD Series. Change-Over Return Line Filter Service and Parts. 2. Element Replacement. 2.1 Element Removal

Filters. RFD Series. Change-Over Return Line Filter Service and Parts. 2. Element Replacement. 2.1 Element Removal 1. Maintenance Filters Series Change-Over Return Line Filter Service and Parts up to 343 gpm (1300 l/min), up to 362 psi (420 bar) 1.1 General Please follow the maintenance instructions. 1.2 Installation

More information

Off-line filter system

Off-line filter system Off-line filter system 30 NFF2, 50 NFF2, 80 NFF2 RE 51433-B/04.10 Replaces: -.- English Operating instructions The data specified above only serve to describe the product. No statements concerning a certain

More information

RKM Series Service and Parts

RKM Series Service and Parts Filters RKM Series Service and Parts up to 211 gpm (800 l/min), up to 145 psi (10 bar) 1. Maintenance 1.1 General Please follow the maintenance instructions on the last page. 1.2 Installation Before installing

More information

RFL Cast Series Service and Parts

RFL Cast Series Service and Parts Filters RFL Cast Series Service and Parts up to 343 gpm (1300 l/min), up to 580 psi (40 bar) 1. Maintenance 1.5 Torque Values 2. Element Replacement 1.1 General Please follow the maintenance instructions.

More information

Spare Parts List Return Line Filter RFM with 4-hole attachment

Spare Parts List Return Line Filter RFM with 4-hole attachment Spare Parts List Return Line Filter with 4-hole attachment Tank-top mounted version: up to 850 l/min, up to 10 bar 75 90 150 165 185 195 210 270 330 500 600 661 851 1. MAINTENANCE GENERAL Please follow

More information

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds for assembly, commissioning and maintenance of valves and hydraulic manifolds 110210_general_operating_manual 07.2018 Table of contents Contents Page Important information 2 Important safety instructions

More information

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM 150 150 150 This instruction manual contains proprietary information which is protected by copyright laws. No part of

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use! Operating instructions Pneumatic Crimper AC 100 Date of issue: 05/2010 Keep for future use! SAFETY SAFETY Basic information The basic prerequisite for ensuring safe use and continuous operation of the

More information

Model C230 Pump Controller

Model C230 Pump Controller MANUAL Model C230 Earthsafe Systems, Inc. 7553 S. Madison Willowbrook, IL 60527 T: (630) 794-5100 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com March 1, 2010 The information contained herein is

More information

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Installation Guide WBP-Box-IEN103320 IMEN-WBP-BOX Version 2.0 EN SMA Solar Technology AG Table of Contents Table of Contents

More information

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 EN Operating manual Motorised zone valve Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 This manual ensures safe and efficient use of the 3PV2 or 3PV8 force-actuated three-way valve with spring-loaded return

More information

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.: Operating manual HDA eco Box 12/24V DC Automatic Dispenser Item No.: 110 500 900 Translation of the original operating manual Important! Copyright The operating manual is always to be read before commissioning

More information

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019 Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 DE-74363 Güglingen Telefon: +49(0)7135-102-0 Service: +49(0)7135-102-211 Telefax: +49(0)7135-102-147 E-Mail:

More information

Assembly and Maintenance Manual Type AS

Assembly and Maintenance Manual Type AS Assembly and Maintenance Manual Type AS Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_AS.docx

More information

Assembly and Maintenance Manual Type RSBW

Assembly and Maintenance Manual Type RSBW Assembly and Maintenance Manual Type RSBW Hatschekstr. 36 69126 Heidelberg Germany Tel +49(0)6221 30470 Tel +49(0)6221 304731 info@stieber.de www.stieber.de Stieber Clutch Date of issue: 16/03/2017 GB

More information

Pressure Filter DF...K P, DF...M P, Flange Mounted

Pressure Filter DF...K P, DF...M P, Flange Mounted Pressure Filter, DF...M P, Flange Mounted up to 550 l/min, up to 260 bar DF...M P 330...1.X 160 240 280 500...1.X 660...1.X 660...2.X 990...2.X 1320...2.X 660...3.X 990...3.X 1320...3.X 1. TECHNICAL SPECIFICATIONS

More information

Operating Instructions. TM Girder Clamps

Operating Instructions. TM Girder Clamps Operating Instructions TM Girder Clamps Original operating instructions in keeping with the EC Machinery Directive TM-BC-10 TM-BC-20 TM-BC-30 TM-BC-50 TM girder clamps meet requirements as per EU Machinery

More information

Assembly instructions PRORUNNER mk1 2

Assembly instructions PRORUNNER mk1 2 Assembly instructions PRORUNNER mk1 Version 0.1 / 01-JUN-2013 Copyright Qimarox B.V. All rights reserved. No part of this document may be copied, stored in a database and/or published by means of printing,

More information

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI Type FSO, FSO-GR, FS, HPI Hatschekstr.36 69126 Heidelberg Deutschland Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 23.08.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\M1124E_0_FSO_FSO-GR_FS_HPI.docx

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

FluidAqua Mobil FAM-200

FluidAqua Mobil FAM-200 FluidAqua Mobil FAM-200 Mechanical and Electrical Erection Instructions English Doc.: 3343369c en / 2007-09-17 Siemens (PG) Trademarks The trademarks of other companies are exclusively used for the products

More information

LowViscosity Housing Filter LVH-F

LowViscosity Housing Filter LVH-F LowViscosity Housing Filter LVH-F Description The LowViscosity-Housing Filter LVH-F is mainly used to filter low-viscosity fluids. It is especially suitable for applications with large amounts of dirt

More information

Operating instructions and spare parts list. LM01 Level sensor. Translation of the original operating instructions

Operating instructions and spare parts list. LM01 Level sensor. Translation of the original operating instructions En Operating instructions and spare parts list LM01 Level sensor Translation of the original operating instructions Documentation LM01 Level sensor Copyright 2005 Gema Switzerland GmbH All rights reserved.

More information

HFM Series Service and Parts

HFM Series Service and Parts Filters HFM Series Service and Parts up to 37 gpm (140 l/min), up to 5800 psi (400 bar) 1. Maintenance 1.1 General Please follow the maintenance instructions. 1.2 Installation Before installing the filter

More information

KeContact P20. User manual

KeContact P20. User manual KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 050 NPK 0100 Operating and Installation Instructions Read and observe these Operating and Installation Instructions! KNF Neuberger GmbH Alter Weg 3 D-79112

More information

Operating instructions and spare parts list. Waste powder conveying from recovery container WPS01

Operating instructions and spare parts list. Waste powder conveying from recovery container WPS01 En Operating instructions and spare parts list Waste powder conveying from recovery container WPS01 Documentation WPS01-PP03 Copyright 2006 ITW Gema GmbH All rights reserved. This publication is protected

More information

MANUAL. Single charger

MANUAL. Single charger MANUAL Single charger HST-PR-2830 & HST-PR-2830USA for HS-Technik batteries HST-PR-18xx HST-PR-14xx issue date: November 2016 Table of contents Page 1. Basic information...3 1.1. Purpose of this document...3

More information

WPS02 Waste powder conveying with BIG-BAG station

WPS02 Waste powder conveying with BIG-BAG station En Operating instructions and spare parts list WPS02 Waste powder conveying with BIG-BAG station Translation of the original operating instructions Documentation WPS02 Copyright 2008 ITW Gema GmbH All

More information

MV Series Motors Operation & Parts Manual

MV Series Motors Operation & Parts Manual MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US For use with M3V s/n 101057 & below, M3V-UK s/n 103013 & below, M5V & M5V-US s/n 102972 & below. EU Declaration of Conformity Finish Thompson

More information

Micro Diaphragm Gas Sampling Pumps

Micro Diaphragm Gas Sampling Pumps Operating and Installation Instructions Micro Diaphragm Gas Sampling Pumps Type range: NMP 03 KP DC-B1 NMP 03 KP DC-S NMP 03 KP DC-B3 NMP 03 KP DC-M NMP 03 KP DC-L You have selected a high-quality KNF

More information

LPF Series Service and Parts

LPF Series Service and Parts Filters LPF Series Service and Parts up to 140 GPM(280 l/min), up to 1000PSI(50bar) 1. Maintenance 1.1 General Please follow the maintenance instructions. 1.2 Installation Before installing the filter

More information

Mobile Filter Unit MFU-15

Mobile Filter Unit MFU-15 Mobile Filter Unit MFU-15 Description The MFU 15 MobileFiltration unit is used as a portable service unit for filling hydraulic systems, flushing small hydraulic systems as well as for cleaning in bypass

More information

Change-Over Pressure Filter DFDK

Change-Over Pressure Filter DFDK Change-Over Pressure Filter up to 2500 l/min, up to 315 bar 30 60 110 140 160 240 280 330 500 660 1.x 660 2.x 990 2.x 1320 2.x 1320 3.x 2640 3.x 3960 3.x 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING

More information

Operating Instructions

Operating Instructions Armaturen GmbH Armaturen, Rohre, Sonderteile aus Edelstahl fittings, pipes, special parts of stainless steel Operating Instructions BaseCom butterfly valve Rev.0 / 12.12.2009 Page 1 of 8 BA52290GB.doc

More information

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps UNPK04DC Pressure UNPK04DCB Pressure UNPK04DC Vacuum UNPK04DCB Vacuum KNF Neuberger, Inc 2 Black Forest Rd Trenton, NJ

More information

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709 MANN+HUMMEL ENTARON XD Installation and Maintenance Manual Version 0709 Contact information This installation and maintenance manual is a component part of the scope of delivery. It must be kept in a safe

More information

LF & LFF Series Service and Parts

LF & LFF Series Service and Parts Filters LF & LFF Series Service and Parts up to 174 GPM(660 l/min), up to 1500PSI(100bar) 1. Maintenance 1.1 General Please follow the maintenance instructions. 1.2 Installation Before installing the filter

More information

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer A company of ThyssenKrupp Elevator ThyssenKrupp Aufzugswerke Operating Manual Oil buffer OPERATING MANUAL Printer s imprint All rights reserved. Copyright by: THYSSENKRUPP AUFZUGSWERKE GMBH P.O. box 23

More information

HST -LS Interlocking device (Translation of Original Manual)

HST -LS Interlocking device (Translation of Original Manual) Installation and Operating Manual for Components HST -LS Interlocking device (Translation of Original Manual) HST-LS Ident.-No.: 10268 HST-LS Ident.-No.: 10269 HST-LS, pictured Ident-Nr. 10269 The image

More information

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF up to 600 l/min, up to 315 bar 60 110 140 160 240 280 330 500 660 1.X 660 2.X 990 1320 1. TECHNiCAL SPECIFICATIONS 1.1 FILTER HOUSING

More information

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X Variable Vane Pump, Direct Controlled PV7...A Series 1X / X RE 1 Issue: 1.13 Replaces: 8.8 Sizes 1 to Maximum pressure 1 bar Displacement volume 1 to cm 3 Features Very short control times Low noise Mounting

More information

HST-BL-2830MS & HST-BL-2830MS-USA

HST-BL-2830MS & HST-BL-2830MS-USA HST-BL-2830MS & HST-BL-2830MS-USA Release date: 02/2017 High - System - Technik Im Martelacker 12 D-79588 Efringen-Kirchen Phone 0 76 28-91 11-0 Fax 0 76 28-91 11-90 E-Mail: info@hs-technik.com Web: www.hs-technik.com

More information

Declaration of Conformity as per Directive 97/23/EC

Declaration of Conformity as per Directive 97/23/EC Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany PTFE-lined Rotary plug valves Series 23e, with packing with lever for 90 operation with worm gear

More information

Installation and Operating Instructions

Installation and Operating Instructions Original Installation and Operating Instructions Hawle E2 Valve with Flange Outlet, System 2000 or PE Spigot Ends Table of Contents A) General...... 2 A1 Symbols..... 2 A2 Intended use... 2 A3 Labeling...

More information

Contamination switch VS

Contamination switch VS Contamination switch VS RE 95148 Issue: 12.2015 Replaces: 09.2015 For detecting metallic impurities in oil Inhalt Ordering code 2 Description 2 Technical data 2 Connection 3 Dimensions 3 Safety instructions

More information

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 0283, 0293 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 The operating instructions...2 2 Intended

More information

Micro Diaphragm Gas Sampling Pumps

Micro Diaphragm Gas Sampling Pumps Operating and Installation Instructions Micro Diaphragm Gas Sampling Pumps Type range: NMP830K_DC-M HP NMP830.1.2K_DC-M HP NMP830K_DC-B HP NMP830.1.2K_DC-B HP NMP830K_DC-B4 HP NMP830.1.2K_DC-B4 HP You

More information

Printed: Doc-Nr: PUB / / 000 / 00

Printed: Doc-Nr: PUB / / 000 / 00 ORIGINAL OPERATING INSTRUCTIONS Hilti HTE-P 33 dispenser It is essential that the operating instructions are read before the tool is operated for the first time. Always keep these operating instructions

More information

Hook-in coupling n.b EH EH Operating Instruction English

Hook-in coupling n.b EH EH Operating Instruction English Revision A Datum 10.05.2013 Ersteller NH This operating instruction is not subject to the updating Hook-in coupling n.b. 25 1-EH-025-1-..-..-. 1-EH-025-4-..-.. 1 This coupling is a quality product, in

More information

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves Type 3347-1 and Type 3347-7 Pneumatic Control Valves Type 3347-7, cast body with welding ends Type 3347-7, bar stock body with threaded connections Mounting and Operating Instructions EB 8097 EN Edition

More information

Installation and Operating Instructions Magnetic Vibrator MR 1

Installation and Operating Instructions Magnetic Vibrator MR 1 Installation and Operating Instructions Magnetic Vibrator MR 1 (Translation of the Original Instruction Manual) Würges Vibrationstechnik GmbH Daimlerstraße 9 D-86356 Neusäß Telephone +49 821 999824-00

More information

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH PrioVino Premier Translation of Original Operating Instructions Status: August 2018 First edition January 2018 / PrioVino GmbH Reprint even in extracts only upon written permission by PrioVino GmbH (ISO

More information

A408 GB. Pneumatic oil and diesel pumps 1:1

A408 GB. Pneumatic oil and diesel pumps 1:1 03 594 A408 GB Pneumatic oil and diesel pumps 1:1 G Operating instructions for Pneumatic oil and diesel pump 1:1 Contents 1. General details 2 1.1 Intended use 2 1.2 Design and functional description 2

More information

Filters. DFP, DFPF Series. 2. Element Replacement. 2.1 Element Removal

Filters. DFP, DFPF Series. 2. Element Replacement. 2.1 Element Removal Filters DFP, DFPF Series Manifold Mounted/Reverse Flow Option Service and Parts up to 158 gpm (600 l/min), up to 4500 psi (315 bar) 1. Maintenance 1.1 General Please follow the maintenance instructions.

More information

Type 6213 EV, 6281 EV

Type 6213 EV, 6281 EV Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE QUICK START GUIDE OWNER S MANUAL SAFETY, INSTALLATION, OPERATION & PARTS AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL 877-278-2797 DO NOT RETURN TO STORE! WARNING This equipment must be installed

More information

Clamping and drive module

Clamping and drive module Clamping and drive module RE 51147/10.05 Replaces: 04.02 1/14 Type UPE 3 Drive power 3.0 kw / 4.0 kw Series 1X Maximum operating pressure 700 bar H6842 Overview of contents Contents Page Features 1 Application

More information

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Version with handwheel Mounting and Operating Instructions EB 8039 EN Edition May 2016 Definition of signal

More information

Operating Instructions

Operating Instructions Operating Instructions Ex UPS Combination of > 8265/5 GUBox control panel > 8316 battery box Contents 1 Contents 1 Contents 2 2 General Information 2 3 Safety Instructions 2 4 Conformity to standards 3

More information

Hot Pressing Device PQ-58

Hot Pressing Device PQ-58 Habasit AG Postfach, CH-4153 Reinach-Basel Phone ++41 61 715 15 15 Fax ++41 61 715 15 55 Operating Instructions 36007 Author: Gul/Ni/Nyk Page 1 of 20 Replaces: Edition 03/0102 Hot Pressing Device The is

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Conveyor Belt Misalignment Switch Type MRS 001 Device Identification No.: 91.055 301.001 OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national

More information

DIAPHRAGM LIQUID PUMP NF 2.35

DIAPHRAGM LIQUID PUMP NF 2.35 DIAPHRAGM LIQUID PUMP NF 2.35 NF 2.35 XP DC 24V Supply voltage [Ch. 4] DCB-A XP / XT [Ch. 4] 2.35 NF - / PMLxxxx / PLxxxx [Ch. 1] Operating and Installation Instructions Read and observe these Operating

More information

BODAS Pressure sensor PR3 series 10

BODAS Pressure sensor PR3 series 10 BODAS Pressure sensor PR3 series 10 RE 95155 Edition: 04.2014 Replaces: 12.2013 Measurement ranges to 25, 50, 160, 200, 250, 400, 600 bar Ratiometric output signal 0.5 to 4.5 V with 5 V supply voltage

More information

Operating Instructions K Always on the safe side.

Operating Instructions K Always on the safe side. Operating Instructions K9 4953. Always on the safe side. KaVo Dental GmbH Wangener Straße 78 D-88299 Leutkirch Tel.: 0 75 61 / 86-150 Fax: 0 75 61 / 86-265 A 1 User information...2 A 1.1 Meaning of the

More information

Instruction Manual. Ex-Time 40 / 50

Instruction Manual. Ex-Time 40 / 50 Instruction Manual Ex-Time 40 / 50 Contents 1. Introduction 13 2. Safety Advice 13 3. Faults and Damage 13-14 4. Safety Regulations 14 5. Ex-Data 14-15 6. Technical Data 15-16 7. Use and Application /

More information

Operating manual. Custom made gearboxes

Operating manual. Custom made gearboxes Operating manual Custom made gearboxes DSS-Nr. 100389549 DSS-Rev. 001 Datum 16.01.2018 Contents Contents 1 General information 3 1.1 Using the operating manual 3 1.2 Warnings in this operating manual 4

More information

Exchange of rollers from the XTS-Mover

Exchange of rollers from the XTS-Mover Service documentation for AT901-0050-0550 and AT9011-00x0-0550 Version: Date: 1.0 0.10.017 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1. Documentation issue

More information

Duplex Filter NFD (for NFD UHE (ultra-high efficiency), see NF Series) Service and Parts

Duplex Filter NFD (for NFD UHE (ultra-high efficiency), see NF Series) Service and Parts Filters Duplex Filter NFD (for NFD UHE (ultra-high efficiency), see NF Series) Service and Parts up to 747 gpm (10400 l/min), up to 360 psi (5 bar) 1. Maintenance General Please follow the maintenance

More information