1 FMM-P-L Installation and Maintenance Instructions English (translation of original instructions) Document No.:

2 Trademarks Trademarks The trademarks of other companies are exclusively used for the products of those companies. Copyright 2010 by HYDAC FILTER SYSTMES GMBH all rights reserved All rights reserved. This manual may not be reproduced in part or whole without the explicit written agreement from HYDAC Filter Systems. Contraventions are liable to compensation. Exclusion of liability We made every endeavor to ensure the accuracy of the contents of this document. Consequently, we accept no liability for such errors as may exist nor for any damage or loss whatsoever which may arise as a result of such errors. The content of the manual is checked regularly. Any corrections required will be incorporated in future editions. We welcome any suggestions for improvements. All details are subject to technical modifications. Technical specifications are subject to change without notice. HYDAC FILTER SYSTEMS GMBH Postfach Sulzbach / Saar Germany Documentation Representative Mr. Günter Harge c/o HYDAC International GmbH, Industriegebiet, Sulzbach / Saar Telephone: ++49 (0) Telefax: ++49 (0) guenter.harge@hydac.com HYDAC FILTER SYSTEMS GMBH en Page 2 / 28

3 Contents Contents Trademarks...2 Documentation Representative...2 Contents...3 Preface...5 Customer Service...6 Modifications to the Product...6 Warranty...6 Using the Documentation...7 Safety Information and Instructions...8 Obligations and Liability...8 Explanation of Symbols and Warnings, etc....9 Proper/Designated Use...9 Improper Use...9 Informal Safety Precautions...10 Training and Instruction of Personnel...11 Safety Measures to Be Followed during Normal Operation...11 Maintenance, Servicing and Troubleshooting...12 Modifications to the FMM...12 Storing the FMM...12 Checking the Scope of Delivery...13 FMM Features...14 Restrictions Pertaining FMM-P-L-0-CS1xx Restrictions Pertaining FMM-P-x-1-CS1xx Continuously rotatable display...15 Hydraulic schematic...16 Dimensions...16 FMM components...17 Attaching the FMMP mechanically...18 FMM hydraulic installation...19 Connecting FMM with the hydraulic system...21 Error messages / Troubleshooting...22 Performing Maintenance...22 Maintenance interval...22 Changing the Filter Element...23 Decommissioning the FMM...24 HYDAC FILTER SYSTEMS GMBH en Page 3 / 28

4 Contents Disposing of the FMM...24 Spare Parts and Accessories...25 Technical data...26 Customer Service...26 Model Code...27 HYDAC FILTER SYSTEMS GMBH en Page 4 / 28

5 Preface Preface We have compiled the most important instructions for the operation and maintenance of our product for you, its user, in this documentation. It will acquaint you with the product and assist you in using it as intended in an optimal manner. Keep it in the vicinity of the product so it is always available. Note that the information on the unit's engineering contained in the documentation was that available at the time of publication.there may be deviations in technical details, figures, and dimensions as a result. If you discover errors while reading the documentation or have additional comments or suggestions, contact us at: HYDAC FILTER SYSTEMS GMBH Technische Dokumentation Postfach Sulzbach / Saar Germany We look forward to receiving your input. Putting experience into practice HYDAC FILTER SYSTEMS GMBH en Page 5 / 28

6 Preface Customer Service Contact our technical sales department if you have any questions on our product. When contacting us, please always include the model/type designation, serial no. and part-no. of the product: Telefax: ++49 (0) Modifications to the Product We would like to point out that changes to the product (e.g. purchasing additional options, etc.) may mean that the information in the operating instructions is no longer applicable or adequate. After modification or repair work that affects the safety of the product has been carried out on components, the product may not be returned to operation until it has been checked and released by a HYDAC technician. Please notify us immediately of any modifications made to the product whether by you or a third party. Warranty For the warranty provided by us, please refer to the General Terms of Sale and Delivery of HYDAC Filter Systems GmbH. Refer to these at General terms and conditions. HYDAC FILTER SYSTEMS GMBH en Page 6 / 28

7 Preface Using the Documentation Note that the method described for locating specific information does not release you from your responsibility of carefully reading these instructions prior to starting the unit up for the first time and at regular intervals in the future. What do I want to know? I determine which topic I am looking for. Where can I find the information I m looking for? The documentation has a table of contents at the beginning. There, I select the chapter I'm looking for and the corresponding page number. Chapter description Page number Edition date Documentation no. with index/ file name Document language The documentation number with its index enables you to order another copy of the operating and maintenance instructions. The index number is incremented upward by one number every time the manual is revised or changed. HYDAC FILTER SYSTEMS GMBH en Page 7 / 28

8 Safety Information and Instructions Safety Information and Instructions These operating instructions contain the key instructions for properly and safely operating the FMM. Obligations and Liability The basic prerequisite for the safe and proper handling and operation of the FMM is knowledge of the safety instructions and warnings. These operating instructions in general, and the safety precautions in particular, are to be adhered to by all those who work with the FMM. Adherence is to be maintained to pertinent accident prevention regulations applicable at the site where the product is used. The safety precautions listed herein are limited solely to using the FMM. The FMM has been designed and constructed in accordance with the current state of the art and recognized safety regulations. Nevertheless, hazards may be posed to the life and limb of the individual using the product or to third parties. Risk of damage may be posed to the product or other equipment and property. The FMM is only to be used as follows: solely for its designated use only when in a safe, perfect condition Any faults or malfunctions which might impair safety are to be properly repaired or remedied immediately. Our General Terms and Conditions apply. They are provided to the owner upon conclusion of purchase of the unit at the latest. Any and all warranty and liability claims for personal injuries and damage to property shall be excluded in the event they are attributable to one or more of the following causes: improper use of the FMM or use deviating from its designated use improper assembly, installation, commissioning, operation and maintenance of the FMM modifications to the FMM made by the user or purchaser Improper monitoring of unit components that are subject to wear and tear Improperly performed repair work HYDAC FILTER SYSTEMS GMBH en Page 8 / 28

9 Safety Information and Instructions Explanation of Symbols and Warnings, etc. The following designations and symbols are used in this manual to designate hazards, etc.: DANGER WARNING CAUTION NOTICE DANGER denotes situations which can lead to death if safety precautions are not observed. WARNING denotes situations which can lead to mortal injury if safety precautions are not observed. CAUTION denotes situations which can lead to severe injuries if safety precautions are not observed. NOTICE denotes situations which can lead to property damage if safety precautions are not observed. Proper/Designated Use The FMM was developed for the continuous monitoring of particulate contamination and water content in hydraulic systems. Analyzing the size and quantity of contamination enables quality standards to be verified and documented and the requisite optimization measures to be implemented. Any other use shall be deemed to be improper and not in keeping with the product's designated use. Proper or designated use of the product extends to the following: Maintaining adherence to all the instructions contained herein. Performing requisite inspection and maintenance work. Improper Use Any use deviating from the proper/designated use described above is prohibited. Improper use may result in hazard to life and limb. Example of improper use: Improper connection of the pressure and return lines of the FMM. HYDAC FILTER SYSTEMS GMBH en Page 9 / 28

10 Safety Information and Instructions Informal Safety Precautions Always keep the operating instructions in the vicinity of the measurement unit. Apart from the operating instructions, any and all general and local regulations pertaining to accident prevention and environmental protection are to be made available and observance is to be maintained to them. Make sure to keep the safety and hazard symbols and warnings on the FMM in a legible condition. Check the hoses and connection fittings for leakage daily (visual check). The electrical components of the FMM are to also be regularly checked (visual check once a month). Replace any loose connections or damaged cables immediately. WARNING Hydraulic systems are under pressure Bodily injury The hydraulic system must be depressurized before performing any work on the hydraulic system. HYDAC FILTER SYSTEMS GMBH en Page 10 / 28

11 Safety Information and Instructions Training and Instruction of Personnel The FMM may only be operated by properly trained and instructed personnel. The areas of responsibility of your staff must be established in a clear-cut manner. Staff undergoing training may not use the FMM unless supervised by an experienced staff member. Individuals Personnel undergoing training Personnel with technical training/ engineering background Electrician Supervisor with the appropriate authority Activity Packing Transportation X X X Commissioning X X X Operation X X X X Troubleshooting/ locating the source of malfunction X X X Remedying of mechanical faults X X Remedying of electrical faults X X Maintenance X X X X Repair work X Decommissioning/storage X X X X Safety Measures to Be Followed during Normal Operation Do not operate the FMM unless all the safety devices function properly. The product is to be checked once a day for external damage and the proper functioning of the safety devices. HYDAC FILTER SYSTEMS GMBH en Page 11 / 28

12 Storing the FMM Maintenance, Servicing and Troubleshooting The prescribed adjustment, maintenance/servicing and inspection work is to be conducted in a timely fashion. Disconnect the FMM from the power supply and protect the entire system from being inadvertently switched on when performing maintenance, inspection or repair work. Check any screwed fittings which have been removed to see that they have been properly secured. Always check the product to see that it functions properly when performing maintenance and servicing work. Modifications to the FMM Do not make any modifications (design modifications, extensions) to the FMM without the prior consent of the manufacturer. Any modifications require written permission from HYDAC Filter Systems GmbH Immediately replace any machine components which are not in perfect condition. Use only original spare parts. Storing the FMM Store the FMM in a clean, dry place, in the original packing if possible. Do not remove the packing until you are ready to install the unit. Drain the FMM completely before putting it into storage. If necessary, rinse the FMM with n-heptane to prevent it from gumming up during storage. The cleaning agents and flushing oils used are to be handled and disposed of properly. HYDAC FILTER SYSTEMS GMBH en Page 12 / 28

13 Checking the Scope of Delivery Checking the Scope of Delivery The Fluid Monitoring Module FMM Unit comes packed and factory-assembled. Before starting up the FMM, check that the content of the package is complete. The following items are supplied: Item Qty. Description Connector (female) with 8-pole, M12x1, shielded 3 1 Connector (female), 5-pole, M12x1-1 Operating and Maintenance Instructions FMM (this document) - 1 Operating and maintenance instructions AS CD-ROM with: - Software CoCoS Operation and maintenance instructions CS CD-ROM with FluMoS Light software - 1 Calibration certificate CS1000 HYDAC FILTER SYSTEMS GMBH en Page 13 / 28

14 FMM Features FMM Features The FMM-P-L Series combines HYDAC's Condition Monitoring Products ContaminationSensor CS 1000 and AquaSensor AS 1000 in one system. The FMM is used as a robust and stationary system for online measurement of solid particle contamination and water content in hydraulic and lubricant fluids (e.g. for the detection of leakages). The FMM features all of the requisite connectors / adapters, enabling it to be easily connected to existing hydraulic circuits. The FMM is suitable for the following operating pressures: FMM with pressure accumulator bar FMM without pressure accumulator bar Advantages offered by the FMM: Cost-effective solution Early warning of critical machine states Continuous fluid monitoring Condition-based maintenance planning HYDAC FILTER SYSTEMS GMBH en Page 14 / 28

15 FMM Features Restrictions Pertaining FMM-P-L-0-CS1xx0 NOTICE Impermissible operating fluid The module will be destroyed The FMM may only be used with mineral oils or mineral oil-based raffinates. Restrictions Pertaining FMM-P-x-1-CS1xx1 CAUTION Impermissible operating fluid The module will be destroyed The FMM may only be used with HDFR fluids (phosphoric acid esters, e.g. Skydrol, Fryquel, Hyjet). Continuously rotatable display The CS 1000 display can be continuously rotated by a total of counterclockwise and 90 clockwise. To rotate the display, grasp the cover plate with your hand and turn in the desired direction. No tools are required for rotating the display. HYDAC FILTER SYSTEMS GMBH en Page 15 / 28

16 Hydraulic schematic Hydraulic schematic Dimensions HYDAC FILTER SYSTEMS GMBH en Page 16 / 28

17 FMM components FMM components Item Description 1 FMM Installation block 2 ContaminationSensor CS 1000 series 3 Connector (female), 8-pole, M12x1 4 AquaSensor AS 1000 series 5 Connector (female), 5-pole, M12x1 6 Inlet (IN), with test connector type 1604 or G ¼ according to ISO 228r 7 Outlet (OUT), with test connector type 1604 or G ¼ according to ISO Test connection (TP1), test connector Type Test connection (TP2), test connector Type Pressure accumulator 11 Filter element (installed) HYDAC FILTER SYSTEMS GMBH en Page 17 / 28

18 Attaching the FMMP mechanically Attaching the FMMP mechanically We recommend installing the unit vertically, so that the flow direction is from bottom to top. When selecting the installation site, check the ambient conditions such as temperature, dust, water, etc. The CS features a protection rating of IP 67 according to DIN / EN60529 / IEC 529 / VDE Fastening can be carried out by means of the four holes in the connection stock with four M6 screws in accordance with ISO 4762 (minimum length 80 mm). HYDAC FILTER SYSTEMS GMBH en Page 18 / 28

19 FMM hydraulic installation FMM hydraulic installation WARNING Non-permitted operating pressure Bodily injury Note the maximum operating pressure of 300 bar. NOTICE The minimum differential pressure is < 15 bar If the minimum differential pressure is not given, measuring errors will occur. Always observe the minimum differential pressure of 15 bar To minimize measurement errors resulting from trapped air in the system, we recommend that the flow direction through the FMM is from bottom (IN) to top (OUT). The FMM comes delivered with four test connectors (Type 1604), one at the inlet (IN) and one at the outlet (OUT) port, as well as at the two testing points (TP1 / TP2). If the hydraulic connection is done via the connector thread G 1/4 according to ISO 228, the test connectors must be removed. HYDAC FILTER SYSTEMS GMBH en Page 19 / 28

20 FMM hydraulic installation HYDAC FILTER SYSTEMS GMBH en Page 20 / 28

21 Connecting FMM with the hydraulic system Connecting FMM with the hydraulic system WARNING Hydraulic systems are under pressure Bodily injury The hydraulic system must be depressurized before performing any work on the hydraulic system. Connect the FMM with the hydraulic system as follows: 1. Check the pressure at the measurement point. It must be within the permissible range. 2. The hydraulic system has to be completely depressurized. 3. First connect the return-flow line to the outlet port (OUT) of the FMM. (connector thread G1/4 ISO 228 or test connection 1604) We recommend an internal Ø 4 mm for the return line. 4. Now connect the other end of the return line to the system tank, for example. 5. Now connect the measurement line to the inlet port (IN) of the FMM. (connector thread G1/4 ISO 228 or test connection 1604) We recommend an internal Ø 4mm for the pressure line in order to prevent particle deposits. 6. Now connect the other end of the measurement line to the measurement point. The hydraulic installation of the FMM is complete. HYDAC FILTER SYSTEMS GMBH en Page 21 / 28

22 Error messages / Troubleshooting Error messages / Troubleshooting The following error messages may result when the CS 1000 is combined with the FMM manifold block. LED Blink code / Display / Analog output / Switch out Status To do Check flow Red 4.4 ma / 2.2 V* open Flow too low Increase inlet pressure or check outlet pressure at measurement point. p has to be at least 15 bar -> if OK, replace filter element. Red 19.9 ma / 9.95 V* open Flow specification not possible Sensor status is undefined Check flow If the oil quality is below the measurement limit (ISO 9/8/7), it may take several measurement cycles until measured values are displayed Increase inlet pressure or check outlet pressure at measurement point. p has to be at least 15 bar -> if OK, replace filter element. For other error messages, please refer to your CS 1000 operating and maintenance instructions. Performing Maintenance Maintenance interval Replace the filter element at least every six months. HYDAC FILTER SYSTEMS GMBH en Page 22 / 28

23 Performing Maintenance Changing the Filter Element WARNING Hydraulic systems are under pressure Bodily injury The hydraulic system must be depressurized before performing any work on the hydraulic system. Item Description 10 O-ring 10.77x Filter element 25 µm 30 O-ring 20x2 40 Support ring Ø Screw plug HYDAC FILTER SYSTEMS GMBH en Page 23 / 28

24 Decommissioning the FMM When changing the filter element, proceed as follows: 1. Unscrew the screw plug (50) with an Allen wrench (size 10) by turning it counterclockwise, then remove it. 2. Remove the filter element. 3. Remove all old seals and gaskets under the filter element and at the screw plug. 4. Clean the dirt and oil from the screw plug (50) and the element mount bore using a clean absorbent, lint-free cloth. 5. Insert the O-ring (10) into the groove under the filter element in the block designated for that purpose. 6. Put the filter element (20) into the mount bore with the opening facing in the direction of the block. The shape of the bore centers the filter element. 7. Mount the support ring (40) and the O-ring (30) to the screw plug (50). Be sure to use the correct sequence and to mount cleanly and perfectly. 8. Wet the O-ring (30) and the support ring (40) with medium. 9. Turn the screw plug (50) clockwise manually, then tighten it with an Allen wrench (size 10). (Tightening torque: 8-10 Nm) Decommissioning the FMM To decommissioning the FMM, proceed according to the following steps: 1. Remove the electric plug to the CS1000 and AS Depressurize the system. 3. Remove the connected hoses/piping from the FMM. 4. Remove the FMM. Disposing of the FMM Dispose of the packaging material as appropriate for your area. When decommissioning and/or disposing of the FMM, observe all local guidelines and regulations pertaining to occupational safety and environmental protection. This applies in particular to the oil in the unit, components covered with oil and electronical components. After disassembling the unit and separating the various materials, reuse them or dispose of them properly in accordance with local regulations. HYDAC FILTER SYSTEMS GMBH en Page 24 / 28

25 Spare Parts and Accessories Spare Parts and Accessories Description Qty Part no. Screws for securing the CS Accumulator SBO (40 bar gas pressure) Screw coupling, Type Filter element replacement kit (FPM), consisting of: - 2x O-ring, 1x support ring, 1x filter element Filter element replacement kit (EPDM), consisting of: - 2x O-ring, 1x support ring, 1x filter element Description Qty Part no. Socket plug (female), 8-pin, M12x1, with screw clamp Socket plug (female) with 2 m line, shielded, 8-pole, M12x1 Socket plug (female) with 5 m line, shielded, 8-pole, M12x1 Extension cable 5 m, socket plug (female) 8-pole, M12x1 / socket plug (male) 8-pole, M12x Socket plug (female), 5-pole, M12x1, with screw clamp For more spare parts and accessories, please refer to the product documentation. HYDAC FILTER SYSTEMS GMBH en Page 25 / 28

26 Technical data Technical data Technical Data FMM Mounting position vertical, with the direction of flow from bottom to top. Operating pressure, maximum = without accumulator bar / psi with accumulator bar / psi Differential pressure > 15 bar Connectors (IN / OUT) Test point type 1604 / thread G¼ according ISO 228 Sealing material Permissible viscosity range Fluid temperature range Ambient temperature range Storage temperature range Weight FPM mm²/s 0 85 C / F C / F C / F 12.5 kg For further technical details, please refer to the operating and maintenance manuals of the respective component. Customer Service Shipping address for calibration and repair: HYDAC SERVICE GmbH Rehgrabenstrasse, Werk Saarbrücken Dudweiler Telephone: ++49 (0) Telefax: ++49 (0) service@hydac.com HYDAC FILTER SYSTEMS GMBH en Page 26 / 28

27 Customer Service Model Code Product FMM = Hydraulic application P = Pressure Line (pressure circuit > 15 bar) Sensor combination L = CS AS HydacLab* Seal 0 = FPM 1 = EPDM ContaminationSensor CS 1000 series CS1210 = ISO / SAE, without display (FPM) CS1220 CS1310 CS1320 CS1211 CS1221 CS1311 = ISO / SAE, with display (FPM) FMM - P - L CS A - AS / 000 = ISO / SAE / NAS, without display (FPM) = ISO / SAE / NAS, with display (FPM) = ISO / SAE, without display (EPDM) = ISO / SAE, with display (EPDM) = ISO / SAE / NAS, without display (EPDM) CS1321 = ISO / SAE / NAS, with display (EPDM) Analogue interface on the CS 1000 A = 4 20 ma B = 0 10 V DC Additional sensor z = Without AS = AS 1000 Z(AS) = Prepared for AS 1000 Hydraulic accumulator 0 = Without 1 = Diaphragm accumulator SBO , 40 bar gas pressure (not available in EPDM) Filter 1 = Protective filter, 25 µm Options 0 = Without Modification number 000 = Modification number *) Set up for HydacLab HYDAC FILTER SYSTEMS GMBH en Page 27 / 28

28 HYDAC FILTER SYSTEMS GMBH Industriegebiet Postfach Sulzbach/Saar Sulzbach/Saar Germany Germany Phone: +49 (0) Central Fax: +49 (0) (Technical Department) Fax: +49 (0) (Sales Department) Internet:

CSM 1000 Series. ContaminationSensor Module. Operating and Maintenance Instructions. English (translation of original instructions)

CSM 1000 Series. ContaminationSensor Module. Operating and Maintenance Instructions. English (translation of original instructions) ContaminationSensor Module Operating and Maintenance Instructions English (translation of original instructions) Documentation no.: 3265074g (from series no. 4555/2009) Trademarks Trademarks The trademarks

More information

Filtromat OF5LxxPxMxB

Filtromat OF5LxxPxMxB Filtromat Operating and Maintenance Instructions English (translation of original instructions) Document No.: 3594726a Trademarks Trademarks The trademarks of other companies designate the products of

More information

MRF D3 MultiRheo Filter

MRF D3 MultiRheo Filter MRF D3 MultiRheo Filter Operating and Maintenance Instructions English (translation of original instructions) Document no.: 3217120b Imprint Imprint Publisher and responsible for the content: HYDAC FILTER

More information

WBF /-T003 bar magnet insert for Wombat filter housing

WBF /-T003 bar magnet insert for Wombat filter housing WBF /-T003 bar magnet insert for Wombat filter housing Installation and Maintenance Instructions English (translation of original instructions) Document No.: 4332365 Imprint Imprint Manufacturer / publisher

More information

Court of Registration: Saarbrücken, HRB Haering

Court of Registration: Saarbrücken, HRB Haering LVU-CD-10 LowViscosity Unit CoaleserDiesel with control type: Eco Operating and Maintenance Instructions English (translation of original instructions) Document No.: 4067271 Keep for future reference.

More information

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z INSTRUCTION MANUAL I/P Converter DSG BXXY3Z DSG BXXY4Z Revision 2.0 3.626 016136 en Page 1/15 Should you have any questions concerning the I/P converter, please contact the Service Department of the Product

More information

Operating instructions

Operating instructions Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future

More information

LVU-CD-10 LowViscosity Unit CoaleserDiesel

LVU-CD-10 LowViscosity Unit CoaleserDiesel LVU-CD-10 LowViscosity Unit CoaleserDiesel with control type: Standard or Premium Operating and Maintenance Instructions English (translation of original instructions) (Valid Series no. 0002S03302K0000010)

More information

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds for assembly, commissioning and maintenance of valves and hydraulic manifolds 110210_general_operating_manual 07.2018 Table of contents Contents Page Important information 2 Important safety instructions

More information

LVU-CD-40 LowViscosity Unit CoalescerDiesel

LVU-CD-40 LowViscosity Unit CoalescerDiesel LVU-CD-40 LowViscosity Unit CoalescerDiesel Operating and Maintenance Instructions English (translation of original instructions) Document No.: 4035823a Keep for future reference. Imprint Imprint Publisher

More information

VarnishElimination Unit- Filtration VEU-F-60/1-x-C

VarnishElimination Unit- Filtration VEU-F-60/1-x-C VarnishElimination Unit- Filtration VEU-F-60/1-x-C Operating and Maintenance Instructions English (translation of original instructions) Keep for future reference. Document No.: 4104528 Imprint Imprint

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

Oil-free piston compressors KK and piston vacuum pumps KV

Oil-free piston compressors KK and piston vacuum pumps KV Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols

More information

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM 150 150 150 This instruction manual contains proprietary information which is protected by copyright laws. No part of

More information

Mobile Filter Unit MFU-15

Mobile Filter Unit MFU-15 Mobile Filter Unit MFU-15 Description The MFU 15 MobileFiltration unit is used as a portable service unit for filling hydraulic systems, flushing small hydraulic systems as well as for cleaning in bypass

More information

FluidAqua Mobil FAM-200

FluidAqua Mobil FAM-200 FluidAqua Mobil FAM-200 Mechanical and Electrical Erection Instructions English Doc.: 3343369c en / 2007-09-17 Siemens (PG) Trademarks The trademarks of other companies are exclusively used for the products

More information

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019 Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 DE-74363 Güglingen Telefon: +49(0)7135-102-0 Service: +49(0)7135-102-211 Telefax: +49(0)7135-102-147 E-Mail:

More information

Assembly and Maintenance Manual Type AS

Assembly and Maintenance Manual Type AS Assembly and Maintenance Manual Type AS Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_AS.docx

More information

OFX7 Operating Maintenance and Troubleshooting Manual L-4219

OFX7 Operating Maintenance and Troubleshooting Manual L-4219 OFX7 Operating Maintenance and Troubleshooting Manual L-4219 L-2999 Created 9.2012 User Manual OFX7 L-4219 - Table of Contents - Preface. 4 Customer Service. 4 Modifications to the Product 4 Warranty.

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

Spare Parts List Return line filter RF

Spare Parts List Return line filter RF Spare Parts List Return line filter up to 15000 l/min, up to 25 bar 30 60 110 160 240 330 450 580 660 950 1300 2500 4000 5200 6500-7800 15000 1. MAINTENANCE 1.1 GENERAL Please follow the maintenance instructions!

More information

WATERFLUX 3070 Quick Start

WATERFLUX 3070 Quick Start WATERFLUX 3070 Quick Start Battery powered electromagnetic water meter Electronic Revision ER 4.3.0_ up to ER 4.3.4_ (SW.REV 4.2.2_ up to 4.2.5_) KROHNE CONTENTS WATERFLUX 3070 1 Safety instructions 4

More information

Exchange of rollers from the XTS-Mover

Exchange of rollers from the XTS-Mover Service documentation for AT901-0050-0550 and AT9011-00x0-0550 Version: Date: 1.0 0.10.017 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1. Documentation issue

More information

Type 6213 EV, 6281 EV

Type 6213 EV, 6281 EV Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

Filters. DFFH & DFFHM Series Service and Parts. Index. This symbol is followed by user tips and particularly useful information

Filters. DFFH & DFFHM Series Service and Parts. Index. This symbol is followed by user tips and particularly useful information 142.9 INLET 1.38 35 OUTLET Index 1.25 31.8 1. General 1.4 Tools Required for Maintenance 1.5 Torque Requirements 2. Maintenance 3. Changing the Element 4. Spare Parts List 5. Replacement Element Model

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions Drive Unit e-drive1 Installation instructions 04/2014 English translation of the original German installation instructions Contents Foreword... 3 Availability... 3 Structural features in the text... 3

More information

LowViscosity Housing Filter LVH-F

LowViscosity Housing Filter LVH-F LowViscosity Housing Filter LVH-F Description The LowViscosity-Housing Filter LVH-F is mainly used to filter low-viscosity fluids. It is especially suitable for applications with large amounts of dirt

More information

RFN Series Service and Parts

RFN Series Service and Parts Filters RFN Series Service and Parts up to 166 gpm (630 l/min), up to 145 psi (10 bar) 1. Maintenance 1.1 General Please follow the maintenance instructions. 1.2 Installation Before installing the filter

More information

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference! Tension Meter FT Series S C H M I D T c o n t r o l i n s t r u m e n t s Edition FT 03.E Model FT Instruction Manual Valid as of: 01.09.2011 Please keep the manual for future reference! Contents 1 Warranty

More information

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709 MANN+HUMMEL ENTARON XD Installation and Maintenance Manual Version 0709 Contact information This installation and maintenance manual is a component part of the scope of delivery. It must be kept in a safe

More information

Condensate Drain Valve AK 45. Original Installation Instructions English

Condensate Drain Valve AK 45. Original Installation Instructions English Condensate Drain Valve AK 45 EN English Original Installation Instructions 810467-03 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED (Pressure

More information

Spare parts list Return line filter RFM with 2-hole attachment

Spare parts list Return line filter RFM with 2-hole attachment Spare parts list Return line filter with 2-hole attachment Tank-top mounted version: up to 200 l/min, up to 10 bar 75 90 150 165 185 195 1. MAINTENANCE 1.1 GENERAL Please follow the maintenance instructions!

More information

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content 1. About this document Operating instructions............pages 1 to 10 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

Application cup for OptiFlex 2 GM03 manual powder gun

Application cup for OptiFlex 2 GM03 manual powder gun En Operating instructions and spare parts list Application cup for OptiFlex 2 GM03 manual powder gun Translation of the original operating instructions Documentation OptiFlex GM03 application cup Copyright

More information

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in Industrial PCs applied in / Logistics and Warehouse / Heavy Duty / Fleet Management / Stationary and Automation DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00 IMPORTANT: Read this manual carefully.

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...

More information

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA PRO-TYP II Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA 3-349-884-03 1/10.15 Opening of Equipment / Repair The equipment may be

More information

Operating instructions and spare parts list. LM01 Level sensor. Translation of the original operating instructions

Operating instructions and spare parts list. LM01 Level sensor. Translation of the original operating instructions En Operating instructions and spare parts list LM01 Level sensor Translation of the original operating instructions Documentation LM01 Level sensor Copyright 2005 Gema Switzerland GmbH All rights reserved.

More information

TIDALFLUX 2300 F Quick Start

TIDALFLUX 2300 F Quick Start Quick Start Electromagnetic flow sensor for partially filled pipes The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS

More information

Assembly Instructions

Assembly Instructions Drive Technology \ Drive Automation \ System Integration \ Services *2450452_0617* Assembly Instructions Didactics - Gear Unit Technology Helical Gear Unit R57F AD2 Edition 06/2017 2450452/EN SEW-EURODRIVE

More information

General Operating Manual

General Operating Manual This Operating Manual is valid for the following hydraulic components of MOTRAC-Hydraulik GmbH: IMA V-Manifold-Blocks Blocks IMA V-Mounting-Units Units Valves and Housings IMA V-Sandwich plates IMA V-Mounting-plates

More information

original operating manual Operating manual Translation of the Item-No.: ,

original operating manual Operating manual Translation of the Item-No.: , Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty

More information

KeContact P20. User manual

KeContact P20. User manual KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially

More information

HST -LS Interlocking device (Translation of Original Manual)

HST -LS Interlocking device (Translation of Original Manual) Installation and Operating Manual for Components HST -LS Interlocking device (Translation of Original Manual) HST-LS Ident.-No.: 10268 HST-LS Ident.-No.: 10269 HST-LS, pictured Ident-Nr. 10269 The image

More information

Conditioning Module Reservoir Extraction CM-RE

Conditioning Module Reservoir Extraction CM-RE Conditioning Module Reservoir Extraction CM-RE Description The ConditioningModule Reservoir Extraction CM-RE is designed as an accessory to the CS ContaminationSensors and the FCU FluidControl Units. The

More information

Tina 4A Connection block

Tina 4A Connection block Original instructions Tina 4A Connection block Instructions valid for versions of the product from ver. H ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read

More information

Installation and Operating Instructions

Installation and Operating Instructions Original Installation and Operating Instructions Hawle E2 Valve with Flange Outlet, System 2000 or PE Spigot Ends Table of Contents A) General...... 2 A1 Symbols..... 2 A2 Intended use... 2 A3 Labeling...

More information

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i) USER MANUAL NEMA 48C Flange Mounted, Enclosed, Clutch Brake FMCBE Model 500 (i) In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual

More information

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN 24550 up to 630 l/min, up to 10 bar RFN 40 RFN 63 RFN 100 RFN 160 RFN 250 RFN 400 RFN 630 1. MAINTENANCE 1.1 GENERAL Please follow

More information

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer A company of ThyssenKrupp Elevator ThyssenKrupp Aufzugswerke Operating Manual Oil buffer OPERATING MANUAL Printer s imprint All rights reserved. Copyright by: THYSSENKRUPP AUFZUGSWERKE GMBH P.O. box 23

More information

Operating instructions and spare parts list. Waste powder conveying from recovery container WPS01

Operating instructions and spare parts list. Waste powder conveying from recovery container WPS01 En Operating instructions and spare parts list Waste powder conveying from recovery container WPS01 Documentation WPS01-PP03 Copyright 2006 ITW Gema GmbH All rights reserved. This publication is protected

More information

WPS02 Waste powder conveying with BIG-BAG station

WPS02 Waste powder conveying with BIG-BAG station En Operating instructions and spare parts list WPS02 Waste powder conveying with BIG-BAG station Translation of the original operating instructions Documentation WPS02 Copyright 2008 ITW Gema GmbH All

More information

Assembly and Maintenance Manual Type RSBW

Assembly and Maintenance Manual Type RSBW Assembly and Maintenance Manual Type RSBW Hatschekstr. 36 69126 Heidelberg Germany Tel +49(0)6221 30470 Tel +49(0)6221 304731 info@stieber.de www.stieber.de Stieber Clutch Date of issue: 16/03/2017 GB

More information

ON SAFEGUARD S ON SAFEGUARD M

ON SAFEGUARD S ON SAFEGUARD M instructions Retrofit option GB ON SAFEGUARD S ON SAFEGUARD M Insulating protective cover Observe additional system documents! General instructions CAUTION Read the operating instructions! The operating

More information

BA EN.=A. Ä.=A.ä. Operating Instructions. Gearbox. Type 12. / 52.

BA EN.=A. Ä.=A.ä. Operating Instructions. Gearbox. Type 12. / 52. BA 12.0028 EN.=A. Ä.=A.ä Operating Instructions Gearbox Type 12. / 52. Product key Gearboxes 1 2... Product group Product family Gearbox size Design Geared motors 1 2... Product group Product family Gearbox

More information

IE3. Motor-pump groups. Type ABAPG and ABHPG. Features. Contents. RE Edition:

IE3. Motor-pump groups. Type ABAPG and ABHPG. Features. Contents. RE Edition: Motor-pump groups Type ABAPG and ABHPG RE 51180 Edition: 2015-02 With pump type: A10VSO Series 52: Size 10, Series 31: Sizes 18 to 140 Electric motor frame size 100L bis 315S Efficiency class IE3 H7890+7894_d

More information

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are

More information

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Version with handwheel Mounting and Operating Instructions EB 8039 EN Edition May 2016 Definition of signal

More information

Hook-in coupling n.b EH EH Operating Instruction English

Hook-in coupling n.b EH EH Operating Instruction English Revision A Datum 10.05.2013 Ersteller NH This operating instruction is not subject to the updating Hook-in coupling n.b. 25 1-EH-025-1-..-..-. 1-EH-025-4-..-.. 1 This coupling is a quality product, in

More information

Model C230 Pump Controller

Model C230 Pump Controller MANUAL Model C230 Earthsafe Systems, Inc. 7553 S. Madison Willowbrook, IL 60527 T: (630) 794-5100 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com March 1, 2010 The information contained herein is

More information

Operating Instructions

Operating Instructions Armaturen GmbH Armaturen, Rohre, Sonderteile aus Edelstahl fittings, pipes, special parts of stainless steel Operating Instructions BaseCom butterfly valve Rev.0 / 12.12.2009 Page 1 of 8 BA52290GB.doc

More information

HST-BL-2830MS & HST-BL-2830MS-USA

HST-BL-2830MS & HST-BL-2830MS-USA HST-BL-2830MS & HST-BL-2830MS-USA Release date: 02/2017 High - System - Technik Im Martelacker 12 D-79588 Efringen-Kirchen Phone 0 76 28-91 11-0 Fax 0 76 28-91 11-90 E-Mail: info@hs-technik.com Web: www.hs-technik.com

More information

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4

More information

Tina 11A Connection block

Tina 11A Connection block Original instructions Tina 11A Connection block ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating instructions...2 2 Intended use...3 3

More information

Spare Parts List Return Line Filter RFM with 4-hole attachment

Spare Parts List Return Line Filter RFM with 4-hole attachment Spare Parts List Return Line Filter with 4-hole attachment Tank-top mounted version: up to 850 l/min, up to 10 bar 75 90 150 165 185 195 210 270 330 500 600 661 851 1. MAINTENANCE GENERAL Please follow

More information

Operating instructions Rescue equipment. Mobile Selection Manifold MSM-2D PN500 - STREAM GB Issue

Operating instructions Rescue equipment. Mobile Selection Manifold MSM-2D PN500 - STREAM GB Issue Operating instructions Rescue equipment Mobile Selection Manifold MSM-2D PN500 - STREAM 179003085 GB Issue 03.2009 5 3 1 2 4 6 6 (Translation of the original operating instructions) Contents Page 1. Danger

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition: Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D RE 51476 Edition: 2015-06 Nominal sizes: 30 to 80D Connection up to G1; SAE 10 56558_d Features Spin-on filters are used in hydraulic

More information

MANUAL. Single charger

MANUAL. Single charger MANUAL Single charger HST-PR-2830 & HST-PR-2830USA for HS-Technik batteries HST-PR-18xx HST-PR-14xx issue date: November 2016 Table of contents Page 1. Basic information...3 1.1. Purpose of this document...3

More information

DeZURIK 2 20" BOS BUTTERFLY VALVES

DeZURIK 2 20 BOS BUTTERFLY VALVES 2 20" BOS BUTTERFLY VALVES Instruction D10459 October 2013 2-20 BOS Butterfly Valves Instructions These instructions provide information about BOS Butterfly Valves. They are for use by personnel who are

More information

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 0283, 0293 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 The operating instructions...2 2 Intended

More information

Operating Instructions

Operating Instructions BA 12.0028 450 298 EN Operating Instructions K12.0549 Typ Gearboxes 12.jjj 52.jjj Product key Gearboxes ➀ ➁ ➂ ➃ Product group Product family Gearbox size Design ➀ ➁ ➂ ➃ 12. 602. 20. 11 Geared motors ➀

More information

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Installation Guide WBP-Box-IEN103320 IMEN-WBP-BOX Version 2.0 EN SMA Solar Technology AG Table of Contents Table of Contents

More information

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704 Elgin Hydraulic Clutch-Brake ECB-20, Product Number 96225 FORM NO. L-20283-F-070 1 FORM NO. L-20283-F-070 In accordance with Nexen s established policy of constant product improvement, the specifications

More information

Emergency Power Supply for the OMEGA ACTIVE-System. Operating Instructions

Emergency Power Supply for the OMEGA ACTIVE-System. Operating Instructions Emergency Power Supply for the OMEGA ACTIVE-System Operating Instructions Preface Preface These Operating Instructions will help you using the Emergency Power Supply as intended, safely, and advantageously.

More information

Off-line filter system

Off-line filter system Off-line filter system 30 NFF2, 50 NFF2, 80 NFF2 RE 51433-B/04.10 Replaces: -.- English Operating instructions The data specified above only serve to describe the product. No statements concerning a certain

More information

The information in this instruction manual is subject to modifications without prior notice and is the exclusive property of Zorzini.

The information in this instruction manual is subject to modifications without prior notice and is the exclusive property of Zorzini. Dear Customer, Thank you for choosing a Zorzini S.p.A. product. Zorzini manway doors and manhole covers 1 are designed and manufactured according to the highest standards in regards safety, functionality

More information

TSS Tool Stand. Installation and Operation Manual. Document #:

TSS Tool Stand. Installation and Operation Manual. Document #: TSS Tool Stand Installation and Operation Manual Document #: 9610-20-1068 Engineered Products for Robotic Productivity Pinnacle Park 1031 Goodworth Drive Apex, NC 27539 Tel: +1-919.772.0115 Fax: +1-919.772.8259

More information

RKM Series Service and Parts

RKM Series Service and Parts Filters RKM Series Service and Parts up to 211 gpm (800 l/min), up to 145 psi (10 bar) 1. Maintenance 1.1 General Please follow the maintenance instructions on the last page. 1.2 Installation Before installing

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions

Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions Temposonics Magnetostrictive Linear Position Sensors Table of contents. Introduction...3 2. Safety instructions...4 2. Intended use...4 2.2 Forseeable misuse...4 2.3 Installation, commissioning and operation...5

More information

INSTRUCTION & INSTALLATION

INSTRUCTION & INSTALLATION INSTRUCTION & INSTALLATION MANUAL MODELS: CCL-eHOME T1C16 CCL-eHOME T1C32 CCL-eHOME T2C16 CCL-eHOME T2C32 WALLBOX ehome SERIES WALLBOX ehome Instruction and Installation manual This document is copyrighted,

More information

Contamination switch VS

Contamination switch VS Contamination switch VS RE 95148 Issue: 12.2015 Replaces: 09.2015 For detecting metallic impurities in oil Inhalt Ordering code 2 Description 2 Technical data 2 Connection 3 Dimensions 3 Safety instructions

More information

Installation manual portable distributors

Installation manual portable distributors EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended

More information

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES Instruction D12043 June 2016 DeZURIK Instructions These instructions provide installation, operation and maintenance information for APCO CRF-100A Rubber

More information

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions EB 8313-1 EN Translation of original instructions V2001-IP Control Valve Type 3372 0511/0531 Electropneumatic Actuator with Type 3321 Valve Type 3372 Electropneumatic Actuator Edition July 2013 Note on

More information

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016 Document N0. 1800-09 Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000

More information

Operating Instructions

Operating Instructions Operating Instructions Lubricus Lubrication System LUB - M (24 VDC) Operating Instructions: LUB- M Table of Contents Contents 2 1) General Information 4 1.1 Warning 4 1.2 Scope of supply 4 1.3 Overview

More information

OPTIFLUX 2000 Quick Start

OPTIFLUX 2000 Quick Start OPTIFLUX 2000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS OPTIFLUX 2000

More information

Spare Parts List Filter NFD Change-Over Version

Spare Parts List Filter NFD Change-Over Version Spare Parts List Filter Change-Over Version up to 1600 l/min, up to 5 bar 1340 640 540 7840 10440 1. MAINTENANCE GENERAL Please follow the maintenance instructions! 1. INSTALLATION Before fitting the filter

More information

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00. Operating instructions for operators sonnenprotect 1300 KD-337 Part no. 22010 Version X00 info@sonnenbatterie.de www.sonnenbatterie.de EN IMPORTANT Read this documentation carefully before operation. Retain

More information

Operating instructions Accu Jet

Operating instructions Accu Jet Operating instructions Accu Jet Keep for future use! Ident number: 04.8800.000 Air Line Table of contents 1 Scope of delivery... 4 2 Operator instructions... 5 3 Safety... 6 3.1 Intended use...8 4 Description

More information

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve Series V2001 Valves Type 3321 Globe Valve Type 3321 Globe Valve with rod-type yoke and Type 3372 Electropneumatic Actuator (350 cm²) Mounting and Operating Instructions EB 8111/8112 EN Edition June 2013

More information

ACROBAT SWING STAND MODEL

ACROBAT SWING STAND MODEL Mounting instructions Directions for use ACROBAT SWING STAND MODEL Dr. Mach GmbH u. Co.KG, Flossmannstrasse 28, D-85560 Ebersberg Tel.: +49 (0)8092 2093 0, Fax +49 (0)8092 2093 50 Internet: www.dr-mach.com,

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 6027 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass Electric Drives and Controls Hydraulics Linear Motion and ssembly Technologies Pneumatics Service xial Piston Fixed Motor 2FNM for Fan Drives and Flywheel Mass RE 91007/02.11 1/16 Data sheet Series 61

More information

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS VARIFUEL2 200-120 MAINTENANCE AND REPAIR INSTRUCTIONS MOTORTECH Gas Regulation P/N 01.50.008-200-120-EN Rev. 06/2015 Copyright Copyright 2015 MOTORTECH GmbH. All rights reserved. Distribution and reproduction

More information

OPERATING INSTRUCTIONS INDEPENDENT WHEEL SUSPENSION RL 75 E/EC FRONT AXLE/TAG AXLE RL 75 A

OPERATING INSTRUCTIONS INDEPENDENT WHEEL SUSPENSION RL 75 E/EC FRONT AXLE/TAG AXLE RL 75 A INDEPENDENT WHEEL SUSPENSION RL 75 E/EC FRONT AXLE/TAG AXLE RL 75 A 587.97.90 en Preface This documentation has been developed for specialized staff trained by ZF Friedrichshafen AG for repair and maintenance

More information