Hill AFT/AirAFT Table
|
|
- Laura Bradford
- 5 years ago
- Views:
Transcription
1 Hill FT/irFT Table Owner s Manual 3 N. acton Hill Road, Frazer, P Fax Quality and Innovation Since 1945.
2 Congratulations! nd welcome to the Hill Laboratories family. Hill Laboratories Company has been making quality a family business since Your Hill FT Table is built in a tradition of innovation and value that Hill Laboratories products have become known for. Our good name rests on the confidence that your Hill Table will provide you with solid, reliable service for many years to come.
3 Index O On/Off Switch (See Power utton) P Paper Roll 4 Patient Switch (see Emergency Stop ) Power utton 4, 9, 11 Power Switch 4, 11 Pressure Pedal 2, 5, 6 Problems (See Trouble Shooting) R Raised Headpiece (See Headpieces) S Service and Support See intro, t Your Service Specifications 2 Speed Setting 8 Start utton 9 Stop utton 9 (lso see Emergency Stop ) T Table Components 4 Tension Control Knobs 2, 5, 6 Tiller ar 2, 7, 9 Timer 9 Thoracic reakaway 2, 5 Thoracic Drop (see Drops ) Thoracic Release 2, 5 Trouble Shooting 10, 11 W Warranty See intro, t Your Service Wiring Diagrams
4 Index ir-compressor 4 nkle Support - djusting 2, 8 - Harnesses 2, 8 rmrests 2 utomatic Flexion 8-9 uto Shutdown 4, 11 uto-touch Foot Pedal 4 asic Table Components 2 C Cervical Distraction (see Flexion ) 7 Cervical Flexion (see Flexion ) 7 Cleaning your Table 3 Cautions and Symbols 3 Control Panel - Main 2, 4, 5 - Flexion 2, 8, 9 D Diagrams (See Wiring Diagrams) Drops - Manual 5 - ir Drops 6 - Not popping up 10 E Electrical specifications 2 Electrical Schematics Emergency Stop - Patient Cut-Off Switch 9 F Flexion - uto Cervical 7 Flexion Control Panel 8 F (continued) Foot Pedal - uto-touch 4 - Corded 2, 4 - Rocker 2, 4 Foot Strips 2, 6 Function Control Panel (See Control Panel) G Gripper ars 2, 8 H Headpieces 2, 6, 7 - Dual-Drop 6 - Flexion 7 - Lateral djustment 7 - Raised 7 - Tilting 6 Height Pedal 4 Height Range 2 Horizontal Switch 9 K Knobs (See Tension Control Knobs) L Lateral djustment - Cervical 8 - Pelvic 8, 9 Lifting Capacity 2 Locking Mechanisms - Drops 6, 7 - Headpiece 6, 7 - Lateral Flexion 9 - Thoracic reakaway 5 - Thoracic Release 5 M Manual Drops (See Drops) N Not Working (See uto Shutdown) t Your Service The Hill Laboratories Guarantee. Your Hill Laboratories table has been thoroughly tested and inspected before shipment. ll parts are guaranteed against defect in materials for one full year from the date of purchase. During this period, any such defect will be remedied by Hill Laboratories or by a factory-authorized repair service at no charge. Tables damaged by mishandling or accident will be repaired at a reasonable charge. ll correspondence should be directed to your local dealer, or when this is not possible, to Hill Laboratories directly. We appreciate your business and your confidence in our products. Our aim is to provide you with excellent service and satisfaction for many years to come. Howard. Hill President, Hill Laboratories 15
5 Hill FT Manual Table of Contents Product Features asic Table Components 1.1 Specifications 1.2 Table Care Cleaning your Table 2.1 Caution and Symbol Explanation 2.2 asic Table Operation Preparing the FT for Your Patient 3.1 Height Pedal 3.2 Function Control Panel 3.3 Thoracic Release/Thoracic reakaway 3.4 Using Drops Manual Drops 4.1 ir Drops 4.2 Headpieces Tilting Headpiece 5.1 Dual Drop Headpiece 5.2 Raised Headpiece 5.3 Cervical Flexion Headpiece 5.4 Flexion and Lateral Movement Preparing for Flexion 6.1 Using Flexion 6.2 Using Lateral Movement 6.3 Wiring Diagram - FT, 24VDC, Part 3 Height System for all FT Models. Trouble Shooting Pages Wiring Diagrams Pages Index of Terms Pages
6 Wiring Diagram - FT, 24VDC, Part 2 ir System for all FT Models. Product Features asic Table Components 1. Tilting Headpiece. May include several options 2. Thoracic Drop with Thoracic Release/reakaway. 3. Lumbar Drop 4. Pelvic Drop on Flexion Section 5. Removable Pelvic Flexion Tiller ar 6. Slide-out nkle Support with nkle Harnesses 7. Flexion Control Panel 8. rmrest 9. djustable Patient Gripper ars 10. Power and ir-drop Control Panel (air-models) 11. Rocker Foot Pedal for Height djustment 12. Power Foot Strips for activating ir-drops (optional) 13. ir-pressure Foot Pedal (air-models) 14. Drop Tension Control Knobs 15. Tension Control Handle for Manual Spring-reakaway 16. Cocking Handle for Manual Drop 1.2 Specifications Electric requirement 60 Hz, 110 v~, 5 / irft - 10 (or cycle) Lifting capacity pounds crylic thermo-plastic base Ultra-Cell foam for comfort and shape retention Height Range - 211/2-29 or 221/2-30 Shipping weight approximately lbs. Length - 5' 5" (extends to 6'2" ), with cervical drop to 6 4 Standard width 24, optional
7 Table Care 2.1 Cleaning your Table Hill table upholstery may be cleaned with Hill Laboratories' Vinyl and Leather Cleaner or any household dishwashing liquid mixed with water. Hill also offers Protex Disinfectant Spray and wipes to protect against pathogens, such as MRS, HIV, Staph and the H1N1 Swine Flu Virus. Many stubborn stains can be removed by applying 91% rubbing alcohol (isopropyl alcohol) to the stain and wiping with a dry, soft, lint-free cotton cloth, towel or soft bristle brush. Wiring Diagram - FT, 24VDC, Part 1 ir System for all FT Models. Caution: These solvents are highly flammable; do not use near open flame or intense heat. Wear rubber gloves during all cleaning activities. When cleaning other parts of your table (besides upholstery) use only nonabrasive household detergents and water. 2.2 Caution and Symbol Explanation Caution: lways unplug the table before performing any maintenance. Caution: Check table once a year to make sure all internal and external bolts are secure. Caution: Table should be in its lowest height position when not attended. Caution: In case of power outage, the table will rely on the generator back-up of the facility where installed for powering to its lowest position. Caution: The power cord should be located to avoid risk of tripping or having objects rolled over or placed on top of it. Damaged cords should be replaced with another of hospital grade. Caution: Grounding reliability can only be achieved when connected to an equivalent receptacle marked hospital only or hospital grade. Symbols - Each of the symbols below are used in your table labeling. n explanation of each is below. ~ Dangerous Voltage Type F pplied Ground Symbol Part Symbol Symbol ttention Symbol consult accompanying documents lternating Current Symbol Don t Touch Symbol 3 12
8 Problem The main power board is turning off on it s own. This is likely the uto-shutdown mode operating normally. When the FT is left inactive for 2 hours, the uto-shutdown mode will power the main control board down automatically. To Fix: Simply press the green power button. asic Table Operation 3.1 Preparing the FT for your patient Plug your table into any 110 volt grounded outlet or 220 volt grounded outlet when specified. The Power Switch is located where the power cord exits the table (photo 1). It ships in the OFF position. fter the table is plugged in, press the button in to turn the power on. Paper Roll - Used for facedown treatment. Close the paper cutter located on the side of the headpiece (photo 2) and tear off excess. photo 1 Plug in, then push in to turn ON photo 2 Problem Power Outage: Due to lightning or some other reason, you facility may lose electrical power from time to time. When this happens, your table s power switch will need to be reset. Plug in, then push in to turn ON To Fix: Unplug the table from the wall outlet and wait approximately 30 seconds. Plug the table back in to the outlet and then press the power switch in, (see photo), to the ON position Preparing the ir System For air models, press the Power button of the main Control Panel (photo 3) to start the table s air-compressor. Each of the fuction buttons will light consecutively and then turn off. The compressor will stop when the pressure reaches 90 lbs. See 4.2, Using photo 3 ir-drops for air-feature instructions. Note: The FT is equipped with an uto Shutdown mode which will power down the main control board if the table is inactive for 2 hours. Press the green power button to power the board back up. 3.2 Height Pedal The basic FT is equipped with a dual Rocker Foot Pedal (#11 under Product Features ) which controls the table height from either side of the base. Press the right side of the pedal to elevate; the left side to lower. uto-touch Foot Pedal (Option) The uto-touch Foot Pedal option maintains upward or downward motion even after releasing the pedal. To operate: - With the table at the lowest height, double-touch the UP arrow and release. The table will continue upward until you tap either side of the pedal again. - With the table at the highest height, double-touch the DOWN arrow and release. The table will continue downward until you tap either side of the pedal again. - With the table at any starting height in between, a single-touch up or down will start and stop the motion. 11 4
9 3.3 Function Control Panel For FTs equipped with air functions, the control panel (photo 3) has a power button, drop-selector buttons and a thoracic-breakaway button. fter power, press in any order to activate the corresponding function. 3.4 Thoracic Release / Thoracic reakaway Thoracic Release To operate the Thoracic Release, pull the switch towards you while holding the cushion; adjust to the desired depth and release the switch to lock the cushion. Thoracic Spring-reakaway The standard Thoracic reakaway (non-air) uses a fixed-tension gas shock to create a recoil movement when the thoracic cushion is unlocked (see photo 4). photo 4 Unlock Lock Thoracic ir-reakaway For tables with a Thoracic ir-reakaway, it is necessary to regulate the airpressure before treating your patient. Follow these steps: Trouble Shooting Problem The Pelvic Cushion cocks up but does not stay up. The drop pin has come out of it s track. To Fix: 1. Loosen the Pelvic Drop Tension Knob enough to rotate the drop pin (see in drawing) so that the cross pin () faces and engages the bracket (C) as shown in the photo and drawing below. You may need to use a flat head screw driver to turn the pin from the bottom. Once the pin is turned into the bracket, retighten the Tension Knob. C C 1. Select the THOR (thoracic) button on the main control panel (photo 3). 2. Unlock the thoracic breakaway switch by pulling toward you until it clicks (photo 4). This will allow the cushion to move freely up and down. 3. Press the right side of the Pressure Pedal (#13, page 2) to increase the air-pressure in the thoracic section. Push down on the cushion as you add air to test for desired firmness. 4. Lock the cushion at any point by pushing the thoracic lock switch towards the table until it clicks. e sure to depressurize the thoracic section after locking to prevent an abrupt release when unlocked. Using Drops 4.1 Manual-Drops Cocking handles are located on both sides of each drop. Push the cocking handle up (, 5) to activate the drop. Turn the tension knobs () clockwise to tighten and counterclockwise to loosen (also see caution, pg. 6). photo 5 Problem The Cervical Cushion cocks up but does not stay up. The drop pin has come out of it s L-bracket. To Fix: 1. Loosen the Cervical Drop Tension Knob enough to rotate the drop pin (see in photo) so that the spring pin () faces and engages the bracket (C) as shown in the photo. Once the pin is turned into the bracket, retighten the Tension Knob. C 5 10
10 Horizontal Switch - The Horizontal Switch contols how the table behaves when the Stop utton is pushed. If you want the table to cycle back to the horizontal position when the Stop utton is pushed, set the Horizontal Switch to ON. If you want the table to stop immediately at any point in the flexion cycle when the Stop utton is pushed, set the Horizontal Switch to OFF. Start utton - Push to start the flexion treatment. Stop utton - Push to stop the flexion treatment. Important: See Horizontal Switch (above) for setting Stop utton behavior. Timer - For tables equipped with a timer, flexion can be set to run automatically for up to 30 minutes (photo 17). Patient Cut-Off Switch The patient can stop treatment immediately at anytime using the Patient Cut-Off Switch. The PCO switch is located on the left armrest support (photo 18). Instruct the patient as to photo 18 photo 19 photo 20 photo 17 the location and function of the switch. To resume treatment after stopping, press the green Start utton on the flexion control panel. 6.3 Using Lateral Motion To use Lateral Motion with flexion, insert the flexion handle (tiller) into the receptacle, just above the ankle cushion (photo 19). Disengage the lateral lock handle counter-clockwise (photo 20). This will allow the lower part of the table to move freely from side-to-side. You can also lock the cushion laterally at any point on either side by turning the lock to the 6 o clock position. lso, be sure the handle is locked before patient exits the table. 4.2 ir-drops Drop Selector Switches The Drop Selector Switches (photo 6) activate the table drops. You may choose one or up to four drops simultaneously. Once selected, press the Pressure Pedal (or optional foot strips, #12, pg. 2) to activate the drops. fter discharging, press the pedal or foot strip again to immediately reactivate the drops. Drop Tension Control Knobs The Drop Tension Knobs are located on the left side of each drop (#14, pg. 2). Turn the knob clockwise to increase the firmness of the drop counter clockwise to decrese. Caution: Do not loosen Tension Knobs too far- djusting the tension knobs out too far can cause the cervical and pelvic drops to malfunction. See Trouble Shooting section on pg. 10 for more detail. Headpieces 5.1 Tilting Headpiece ll FT models are equipped with a tilting headpiece. The lever for tilting is located under the front of the headpiece (, photo 7). It controls the angle of tilt 30 positive or negative. Click the switch in to lock; out to unlock. 5.2 Dual-Drop Headpiece photo 6 Photo 7 The Dual-Drop headpiece contains two drops a drop-forward motion and a straight-down drop. Important Note: efore changing any of the settings described in the following section, be sure the headpiece drop is discharged. C 9 6
11 Straight-Down Drop Headpiece To use the Straight-Down Drop of the headpiece, the setting lever should remain in the side channel of the setting mechanism as shown in photo 8. e sure that the pin locks into the receiver behind it otherwise, the drop will not work. For a manual drop, push up on the black cocking handle to engage. For ir- Cervical Drop, see section 4.2. Drop-Forward Motion Headpiece To use the Drop-Forward Motion action of the headpiece, pull the black setting lever out and turn it to the left so that it points straight down (photo 9). For a manual drop, push up on the black cocking handle to engage. For ir-cervical Drop, see section 4.2). 5.3 Raised Headpiece The Raised Headpiece allows the headpiece to rise up to 5 above the surface of the table. It is controlled by a lever in front of the head cushion (7, ). Pull and hold the switch to adjust to the desired height; release to lock. To lower, apply gentle downward pressure to the back side of the headpiece with one hand while pulling the lever to adjust. 5.4 Cervical Flexion Headpiece The Cervical Flexion Headpiece includes the raised headpiece feature, occipital strap and the removable tiller bar. Set Up Position the patient as shown in photo 10. Secure the occipital strap using the Velcro connectors. photo 12 photo 8 photo 9 photo 10 photo 11 Important: Prior to flexion, release the red cushion lock pin by pulling and turning the lever to the left (photo 11). This will allow the cushion to slide in the axial direction for applying manual cervical distraction. Lateral djustment The Cervical Flexion Headpiece includes lateral motion. To use lateral motion, locate the switch as shown in photo 12 (7, C). Pull the lever toward you to click and unlock. This will allow full-range lateral movement. The headpiece can also be locked at any angle in the lateral range. Flexion and Lateral Movement 6.1 Preparing for Flexion pplying flexion with the Hill FT is easy. Follow these steps - Set Up Position the patient comfortably on the table in the face-down position. djust the slide-out ankle support to fit your patient s height using the lever located under the ankle cushion (photo 13). Secure the ankles by firmly fastening the straps with the velcro connectors (photo 14). Now, have your patient grasp the gripper bars (photo 15). The length of the bars can be adjusted by loosening the handle (, 15) and sliding the bars so that the patient can grasp them firmly. Tighten the handles on each bar to secure. The Gripper ars keep the patient from sliding during flexion treatment. photo 14 photo Using Flexion Using the Flexion Control Panel ll of the controls for flexion are conveniently located at the foot end of the FT (see 8, under Product Features ). Speed Setting - The uto Flex has a fixed rate of movement from 1-28 cycles per minute (photo 16). Set to desired speed and press Start (always start with a low speed if there is any concern about a patient s flexibility). Speed can be changed at any time during the cycle. photo 16 Photo
Hill 90C/Air90C Table
Hill 90C/Air90C Table Owner s Manual Quality and Innovation Since 1945. Congratulations! And welcome to the Hill Laboratories family. Hill Laboratories Company has been making quality a family business
More informationStandard Features. Crisp, smooth and impressively fast.
Crisp, smooth and impressively fast. Equipped with the Hill Air-Drop System*, the Air90C allows doctors to select one or up to four drops simultaneously from the convenient, side-mounted, control panel.
More informationElectric Flexion Table E9100
Electric Flexion Table E9100 Eurotech tables are specifically designed for the doctor who wants the ease and convenience of an electric flexion table that does more than simply flex up and down or laterally
More informationPT Line & Orthopedic Hi-Lo Casting Table
INSTRUCTION MANUAL PT Line & Orthopedic Hi-Lo Casting Table PT100 PT200 PT300 Orthopedic Hi-Lo Casting Table TABLE OF CONTENTS TABLE OF CONTENTS Warnings & Symbol Identification... pg 1 Section I: Product
More informationstationary massage table
stationary massage table Operator Manual TABLE OF CONTENTS Warnings... 3 Table Specifications Aura Basic... 4 Aura Lift Back... 5 Aura Deluxe... 6 Installation Caution... 7 Parts Included...7 Instructions
More informationfeatures you desire. Stirrups Foot Section
The HA90E is designed for the varied requirements of the physician whose procedures range from manipulation to OB/GYN. Model HA90E smoothly converts from a flat-top to a seated examination table with the
More informationuser instructions and warranty airflo (battery version) freedom through lightweight solutions
user instructions and warranty airflo (battery version) freedom through lightweight solutions The irflo by Mangar International, is a low pressure air compressor, which has been designed for use with Mangar
More informationbody interior Overview Driver s Seat
body interior Overview The seating in your Blue Bird All American bus is designed for your safety and comfort. The placement and installation of school bus passenger seats is governed by federal regulations.
More informationInstallation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue
Installation Guide VHM Wall Mount Kit for Philips MX600/700/800 and MP60/70 IntelliVue The purpose of this guide is to: 1. Describe attachment of Table Top Mount to Mounting Adapter (page 2). 2. Describe
More informationCentrifuge Operator / Service Manual
3000 Centrifuge Centrifuge Operator / Service Manual cat.# 26230 & 26231 The Q-sep 3000 centrifuge complies with all requirements of UL standard 3101 20, Can/CSA C22.2 No. 1010.1, and Can/CSA C22.2 No.
More informationASX / OUTLANDER SPORT SHIFT KNOB MZ525507EX INSTALLATION AND HANDLING INSTRUCTIONS
ASX / OUTLANDER SPORT SHIFT KNOB MZ55507EX INSTALLATION AND HANDLING INSTRUCTIONS Thank you for purchasing the Mitsubishi Genuine Accessory. To install and use the product correctly with proper knowledge
More informationRT404-FLEX II ROTARY TABLE OPERATING MANUAL
P/N 561447 REV E AUG. 03 REV D NOV. 01 REV C APR. 01 REV B JULY 98 REV A AUG. 97 AUGUST 2003 RT404-FLEX II ROTARY TABLE OPERATING MANUAL 2003 I&J FISNAR INC. RT404-FLEX II ROTARY TABLE NOTE: Unlike the
More informationOperating Instructions for Porsche Junior Seat ISOFIX
Operating Instructions for Porsche Junior Seat ISOFIX 33 Porsche, the Porsche Crest and Tequipment are registered trademarks of Dr. Ing. h.c. F. Porsche AG. Reprinting, even of excerpts, or duplication
More informationInstallation Guide VHM Arm Kit for Philips Heartstart MRx and Heartstart XL+
Installation Guide VHM Arm Kit for Philips Heartstart MRx and Heartstart XL+ The purpose of this guide is to: 1. Describe installation of Arm in channel (page 2). 2. Describe mounting of defibrillator
More informationXPS-ProFeed Shuttle SERVICE MANUAL. Revised:
XPS-ProFeed Shuttle SERVICE MANUAL Revised: 9-14-15 RENA SYSTEMS INC. 910 East Main Street; Suite 200 Norristown, PA 19401-4110 Phone: (610) 650-9170 Fax: (610) 270-3947 Web Site: www.renausa.com SAFETY
More informationKidWalk KidWalk II Dynamic Mobility System
OWNER S MANUAL KidWalk KidWalk II Dynamic Mobility System Manufactured By Prime Engineering A Division of Axiom Industries, Inc. Supplier Info 70111KWOM 2 TABLE OF CONTENTS This owner s manual is organized
More informationA3 Seats and Seat Belts
7DEOHRI&RQWHQWV A3 Seats and Seat Belts A3 Seats and Seat Belts Table of Contents Table of Contents... 1 Safety... 1 Warnings and Cautions... 1 Introduction... 2 List of Figures... 1 Seats... 2 Driver's
More informationCondor Manual. Corporation
Condor Manual Corporation PREFACE IMPORTANT, PLEASE READ CAREFULLY Thank you for your purchase with Amico Accessories Inc. This unit is designed for long lasting performance, providing the end user complies
More informationCABINET REEL OPERATING INSTRUCTIONS
CABINET REEL OPERATING INSTRUCTIONS MODELS 15, 25, 40 & 60 SERIES RAPID-AIR CORPORATION 4601 KISHWAUKEE ST. ROCKFORD, IL 61109-2925 Phone: (815) 397-2578 Fax: (815) 398-3887 Web Site: www.rapidair.com
More informationHA90, HA90E and the 90MD. Hill Adjustables. from Hill Laboratories. Treatment Tables for Physicians and Physical Therapists
HA90, HA90E and the 90MD Hill Adjustables from Hill Laboratories Treatment Tables for Physicians and Physical Therapists Hill Adjustable HA90 The Classic Variable-Height Table Design Shown with Azure and
More informationEZ Way Shower Trolleys
EZ Way Shower Trolleys 2000/3000 Operator s Instructions EZ Way, Inc. PO Box 89 Clarinda, IA 51632 1-800-627-8940 www.ezlifts.com Form 2-207 Rev. 12/14/11 The EZ Way Shower trolley is unique with its side-mounted
More informationInstallation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit
Installation Guide Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit The purpose of this guide is to: 1. Describe attachment of Table Top Mount to Mounting Adapter. 2. Describe attachment of Mounting
More informationADHESION/RELEASE TESTER
ADHESION/RELEASE TESTER MODEL AR-2000 OPERATING INSTRUCTIONS CHEMINSTRUMENTS 510 COMMERCIAL DRIVE FAIRFIELD, OHIO 45014 (513) 860-1598 www.cheminstruments.com Revision 1.0 December 13, 2016 CONTENTS PRODUCT
More informationLumina 28 Traction Drive Model: Battery Burnisher M28036TDQP OPERATION SERVICE PARTS CARE
Lumina 28 Traction Drive Model: Battery Burnisher M28036TDQP OPERATION SERVICE PARTS CARE Table of Contents IMPORTANT SAFETY INSTRUCTIONS...1 OPERATING INSTRUCTIONS...2 INSPECTION...2 ELECTRICAL...2 BATTERIES...2
More informationUser Manual GRX- 950 and GRX- 950 Li
User Manual GRX- 950 and GRX- 950 Li Page 1 of 17 TABLE OF CONTENTS INTRODUCTION 3 BASIC SET- UP 4 TURNING ON YOUR GRX- 950 7 PRECAUTIONS 8 FREE WHEEL MODE 9 GENERAL BATTERY CARE 10 BATTERY INFORMATION
More informationXPS-ProFeed Shuttle SERVICE MANUAL. Revised:
XPS-ProFeed Shuttle SERVICE MANUAL Revised: 1-14-15 RENA SYSTEMS INC. 910 East Main Street; Suite 200 Norristown, PA 19401-4110 Phone: (610) 650-9170 Fax: (610) 270-3947 Web Site: www.renausa.com SAFETY
More informationlifetime limited warranty
lifetime limited warranty Limited lifetime warranty on frame and cross braces One year limited warranty on other components Your Drive brand product is warranted to be free of defects in materials and
More informationMygo Seating System User Instructions
Mygo Seating System User Instructions The Mygo Seating System has been designed to offer a high level of postural positioning while enabling function and mobility. This manual shows how you can quickly,
More information1 2 3a 3b THREADING CARD 9 10 ABC Office
1 2 3a 3b 4 5 6 7 8 9 10 THREADING CARD Important Safety instructions YOUR SAFETY AS WELL AS THE SAFETY OF OTHERS IS IMPORTANT TO GBC. IN THIS INSTRUCTION MANUAL AND ON THE PRODUCT ARE IMPORTANT SAFETY
More informationInstallation Instructions
Reliant Single Control Centerset Lavatory Faucet with SpeedConnect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard
More informationKidwalk User Instructions
Kidwalk User Instructions The Kidwalk has been designed as a posturally supportive mobility system that moves with the child giving them the freedom to move and walk while keeping their hands free to explore
More informationOPERATION and SERVICE MANUAL EC TRANS. CHAIR
OPERATION and SERVICE MANUAL EC TRANS. CHAIR MODEL 900EC THE SERIAL NUMBER WILL BE FOUND ON THE LOWER FRAME AT THE HEAD END. RECORD THE NUMBER BELOW: SERIAL NUMBER: DATE OF PURCHASE ConvaQuip Ind., Inc.
More informationPortable Lighting Equipment Operating Instructions Table of Contents
Portable Lighting Equipment Operating Instructions Table of Generac Magnum Ingersoll Rand TEREX AMIDA TEREX GENIE Model: MLT3060 Model: LIGHTSOURCE Model: Amida AL4000 series Model: TML4000N Generac Magnum
More informationmaterials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax:
WARRANTY The Drucker Company warranties that this centrifuge is free from defects in materials and workmanship for 2 years. Should the centrifuge require warranty or out-of-warranty service please contact:
More informationFreeGo. pump. Training Manual. Freedom for life
FreeGo pump Training Manual Freedom for life Contents Section 1 Set-up What you need Set up the FreeGo pump table top stand 2 Preparation Prepare the FreeGo pump Plug in and turn on Page 1 2 3 4 3 The
More informationKanga TS pediatric frame
Kanga TS pediatric frame Item # KG P800 KG 1000 KG 1200 KG 1400 EU Authorized Representative Drive Medical LTD Ainley s Industrial Estate Elland, West Yorkshire, United Kingdom HX5 9JP www.drivemedical.com
More informationAM-134, AM-140, AM-234, AM-240, AM-334, AM-340, AM-368
This manual has been prepared for the owners and operators of the ARMEDICA AM-Series Hi-Lo Treatment Tables. It contains installation instructions, precautionary instructions and maintenance procedures
More informationAlternating Current Revolution per minute Protective Earth Ground. Protected from dripping water Fuse Attention, Consult Accompanying Document
GLOSSARY OF SYMBOLS: (Symbols and descriptions) Alternating Current Revolution per minute Protective Earth Ground Direct Current On (Power connection Off (power to the mains) disconnection from the mains)
More informationFlorham Park, NJ USA Call (ASCO) for sales or service
Operator s Manual 4000 Series ATS Automatic Open-Transition Transfer Switches D design 30 230A, J design 260 600A, H-design 800 1200A, G-design 1600 4000A, F-design 4000A DANGER is used in this manual
More informationUSER MANUAL. Tides La Mer Treatment Table Rev A 3/28/19. *all tables shown with optional accessories and/or finishes
USER MANUAL Tides La Mer Treatment Table *all tables shown with optional accessories and/or finishes 1-400-0041 Rev A 3/28/19 Living Earth Crafts 2019, All Rights Reserved Legal Notice The information
More informationINSTALLATION INSTRUCTIONS for the LR Chair
INSTALLATION INSTRUCTIONS for the LR Chair SECTION I - REQUIREMENTS 1. PHYSICAL REQUIREMENTS... 1 2. ELECTRICAL REQUIREMENTS... 1 SECTION II - INSTALLATION 1. UNPACKING THE CARTONS... 2 2. UNPACKING THE
More informationDear Customers. : i MiEV INSTRUMENT PANEL ILLUMINATION INSTALLATION AND HANDLING INSTRUCTIONS. Attention
Dear Customers Thank you for purchasing a Mitsubishi genuine optional part. For proper use of the product, please read this leaflet thoroughly. It is recommended you keep this leaflet at hand for future
More informationKidwalk Seating System User Instructions
Kidwalk Seating System User Instructions The Kidwalk has been designed as a posturally supportive mobility system that moves with the child giving them the freedom to move and walk while keeping their
More informationModel 1100B CHG Terminator. Installation Instructions
Model 1100B CHG Terminator Installation Instructions 1 Contents: 1.0 Safety Information... 3 2.0 Set-up and Adjustments... 3 3.0 Ram Adjustments... 10 4.0 Wire Termination Quality... 12 5.0 General Maintenance...
More informationRESTWELL RISE & RECLINE ARMCHAIRS LARS AND SVEN - OWNER S HANDBOOK MODEL DESCRIPTION
RESTWELL RISE & RECLINE ARMCHAIRS LARS AND SVEN - OWNER S HANDBOOK CONTENTS 1. Introduction 2. Model Description 3. Parts Description 4. Personal Safety 5. Installation Instructions 6. Operating Instructions
More informationKidWalk Dynamic Mobility System
KidWalk Dynamic Mobility System OWNER S MANUAL ***Note*** Read Owner s Manual before use. Manufactured By Prime Engineering A Division of Axiom Industries, Inc. Distributed in the: United Kingdom and Republic
More informationOwner s Manual. Bariatric Manual Wheelchairs. Specializing in Bariatric Patient Aids
Owner s Manual Bariatric Manual Wheelchairs 700 LB CAPACITY XL Series Wheelchair by ConvaQuip Specializing in Bariatric Patient Aids P.O. Box 3417 * Abilene, TX 79604 U.S.A. Toll 800/637-8436 * FAX 325/677-7217
More informationSquiggles Seating System User Instructions
Squiggles Seating System User Instructions The Squiggles Seating System has been designed to offer a high level of postural positioning while enabling function and mobility. This manual shows how you
More informationApollo Tilt Wheelchair 18" and 20" Instruction Manual
Apollo Tilt Wheelchair 18" and 20" Instruction Manual Table of Contents Contents Table of Contents... 2 Introduction... 3 Warning... 4 Safety Guidelines... 5 Parts of the Tilt Wheelchair... 6 Setup & Operation...
More informationGENUINE FOG LIGHT INSTALLATION AND USER S INSTRUCTIONS
GENUINE FOG LIGHT INSTALLATION AND USER S INSTRUCTIONS Thank you for purchasing a genuine Mazda accessory. Before removal and installation, be sure to thoroughly read these instructions. Please read the
More informationTR 2000/3000. Operating manual. Shower Trolleys. Hygiene Equipment Designed for People
Operating manual Always study this manual carefully before operating the Shower Trolley. Operating instructions and recommended maintenance procedures are explained in the following pages. Only qualified
More informationEveryday Activity Seat. User Instructions
Everyday ctivity Seat User Instructions The Everyday ctivity Seat is a moderate seating system designed for use in the home and classroom. It comes in 3 sizes with adjustable seat height, depth and width
More informationSnapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle
LX5 Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 5200 NW 108th Avenue, Sunrise, FL 33351 U.S.A.
More informationA B 0 0 C D E 6 7 G F F H 8 9 K M O O L N I J 1
1 2 1 5 4 3 2 2 1 6 3 8 7 1 9 4 C A B 5 0 0 D E 6 G 7 F F H 8 K 9 M O O I J L N 1 GENERAL OPERATIONAL PRECAUTIONS 1. Keep work area clean. Cluttered areas and benches invite accidents. 2. Avoid dangerous
More informationTO ORDER PARTS CALL: (479) or
Owner s Manual Industrial Ergonomic User-Friendly Hand Controls Date Manufactured: / / o Mart Cart XTi 24 Model 03522 - SKU# 280-3522 o Mart Cart XTi 24 Model 03524 - SKU# 280-3524 CONGRATULATIONS You
More informationTactical Laser Illuminator
M6 Operator s Manual Operator s Manual Tactical Laser Illuminator MADE IN THE USA Table of Contents Section Page Warnings and Cautions... 1 Safety Summary... 4 M6 TLI (Tactical Laser Illuminator) Parts
More informationInstruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge
Instruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge REVOLUTIO NARY SCIENCE Manufacturer of Precision Laboratory Equipment Table of Contents Introduction 2 Recommended Safeguards
More informationTHE PHOENIX MODEL 1800 KNEE CPM OPERATOR'S MANUAL SERIES Seeds Road Grove City, OH Fax
TM THE PHOENIX SERIES MODEL 1800 KNEE CPM OPERATOR'S MANUAL www.mckelor.com 6312 Seeds Road Grove City, OH 43123 800.273.5233 Fax 614.871.9353 Phoenix Model 1800 Knee CPM Operator's Manual Section 1 TABLE
More informationMobility Scooters. Owners Manual
Mobility Scooters Owners Manual 1 Electromagnetic Interference ( EMI ) It is very important that you read this manual before using the scooter for the first time including the following information regarding
More informationSide panel, replacing
"VCC147307 EN 20110211" 1(23) Side panel, replacing As the illustrations in this service information are used for different model years and / or models, some variation may occur. However, the essential
More informationRemote engine start INSTALLATION INSTRUCTIONS
GENUINE Remote engine start INSTALLATION INSTRUCTIONS Thank you for purchasing a genuine Mazda accessory. efore removal and installation, be sure to thoroughly read these instructions. Please read the
More informationGo Yonder D-Lite Owner s Manual
Go Yonder D-Lite Owner s Manual Marketed in Australia and New Zealand by Bzooma Pty Ltd ABN 37 640 907 507 TABLE OF CONTENTS Table of Contents... 1 Bzooma Pty Ltd... 1 Introduction... 1 Operation... 1
More informationRESTWELL RISE & RECLINE ARMCHAIRS OWNER S HANDBOOK PARTS DESCRIPTION
RESTWELL RISE & RECLINE ARMCHAIRS OWNER S HANDBOOK CONTENTS 1. Introduction 2. Parts Description 3. Personal Safety 4. Installation Instructions 5. Backrest Removal 6. Operating Instructions and Guidelines
More informationOwner s Manual. Transport / Companion Wheelchairs M4TV M2TF M2TC M2TL HEALTH PRODUCTS, INC.
Owner s Manual M4TV M2TF Transport / Companion Wheelchairs M2TL M2TC HEALTH PRODUCTS, INC. INTRODUCTION Congratulations on the purchase of your new companion chair. Please read this introduction with your
More informationVHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications
3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications
More information2100 Childbearing Bed OPERATIONS MANUAL. For Parts or Technical Assistance
2100 Childbearing Bed OPERATIONS MANUAL For Parts or Technical Assistance 1 800 327 0770 Table of Contents INTRODUCTION........................................................................... 2 SPECIFICATIONS.........................................................................
More informationTECHNICAL INFORMATION S2 Canister Vacuums
TECHNICAL INFORMATION S2 Canister Vacuums 2012 Miele USA Table of Contents A Warning and Safety Instructions... 4 1 General Information... 4 2 Cleaning and Care... 4 2.1 Vacuums and Accessories... 4 2.2
More informationConnector Systems Inc. SS-20 MACHINE MANUAL
Connector Systems Inc. SS-20 MACHINE MANUAL INTRODUCTION Your SS-20 machine comes to you fully equipped and set up to terminate the style of plug you have requested. Our SS-20N will accommodate those
More informationCEILING SPEAKER SYSTEM
INSTRUCTION MANUAL CEILING SPEAKER SYSTEM F-2352SC TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 3 3. FEATURES... 3 4. NOMENCLATURE AND DIMENSIONS... 3 5. INSTALLATION... 4 6.
More informationMygo Seating System User Instructions
Mygo Seating System User Instructions The Mygo Seating System has been designed to offer a high level of postural positioning while enabling function and mobility. This manual shows how you can quickly,
More informationINSTRUCTION MANUAL STANDING WHEELCHAIR. KARMAN HEALTHCARE INC. City of Industry, CA
INSTRUCTION MANUAL STANDING WHEELCHAIR KARMAN HEALTHCARE INC. City of Industry, CA 91748 www.karmanhealthcare.com **Karman Healthcare Inc. Recommends Patient Seek Physicians Counsel Before Purchase TABLE
More informationStealth Power i-tilt
Power Tilts OWNERS MANUAL Stealth Power i-tilt User Manual and Maintenance Guide for Stealth s i-tilt Customer Satisfaction 1.0 Stealth Products strives for 100% customer satisfaction. Your complete satisfaction
More information3 Maintenance. 3 Maintenance. 3.1 Introduction. 3.1 Introduction
3.1 Introduction 3 Maintenance 3.1 Introduction Structure of this chapter This chapter describes all the maintenance activities recommended for the IR 1200. It is based on the maintenance schedule found
More information16" STAND FAN WITH REMOTE
OWNER S MANUAL 16" STAND FAN WITH REMOTE MODEL:FS40-8JR READ AND SAVE THESE INSTRUCTIONS Attention: Pictures in the IM are for reference only. CAUTION Read rules for safe operation and instrucions carefully.
More informationTooling Assistance Center
Safeguards are designed into this application equipment to protect operators and maintenance personnel from most hazards during equipment operation. However, certain safety precautions must be taken by
More informationPreface. Scope of Application. General Requirements for Safety THE SAFETY MARKS USED IN THIS INSTRUMENT
Preface Thank you for purchasing our SL-700 slit lamp. Please read this manual carefully before using this instrument in order to operate it properly and safely. Scope of Application The slit lamp is mainly
More informationSection 10: Engraving Machine Cleaning
Section 10: Engraving Machine Cleaning In This Section Cleaning Important! Laser Tube Cleaning - Important! Fire Warning! Through normal use your laser system can collect debris and soot that are potentially
More informationComfee Seat. User Instructions
Comfee Seat User Instructions The award-winning Comfee Seat is an innovative, supportive and practical seating system designed specifically for leisure time in the home, school or in respite care. It
More informationDelta User Instructions
Delta User Instructions Delta User Information August 2012 Contents IMPORTANT NOTICE 2 Introduction to the Delta chair 2 Delta Product Information 2 Questions and Concerns 2 The User Instructions 3 Guidelines
More informationOWNER`S MANUAL. Corpus II. Seat Assembly for Permobil Power Wheelchair
OWNER`S MANUAL US Corpus II Seat Assembly for Permobil Power Wheelchair How to contact Permobil Permobil Inc. USA 6961 Eastgate Blvd. Lebanon, TN 37090 USA Phone: 800-736-0925 Fax: 800-231-3256 Email:
More informationASSEMBLY AND USER GUIDE
ASSEMBLY AND USER GUIDE "DESIGNED FOR THE OPTIMAL GAMING EXPERIENCE AND UNPARALLELED COMFORT" Congratulations on purchasing your EDGE GX1 gaming chair. The chair has several important adjustments. Spending
More informationHeavy Duty Sprayer Owners Manual Model MS-O
Heavy Duty Sprayer Owners Manual Model MS-O Table of Contents Warranty 4 Warning 5 Assembly and Preparation 6 Operation 7 Cleaning and Storage 7 Standard Spray Gun & Parts List 8 Trigger Style Spray Gun
More informationSERVICE MANUAL (2)
Terra 128B - 132B SERVICE MANUAL 146 0721 000(2)2003-04 INDEX GENERAL INFORMATION 3 MACHINE LIFTING 3 MACHINE TRANSPORTATION 3 OTHER AVAILABLE MANUALS 3 SAFETY - ACCIDENT PREVENTION 4 GENERAL SAFETY RULES
More informationSIGMA. User Manual MB8100GB
SIGMA User Manual Introduction Congratulations on your choice of your new lifting chair. Quality and functionality are keywords for all Handicare lifting chairs. For your own safety, and in order to get
More informationShaver Industries. Assembly Instructions Spring Assist Vertical Vinyl Curtain Door Projection Mount
Shaver Industries 20 Steckle Place, Kitchener, ON N2E 2C3 Ph 1(888) 766 8328 www.shaverinc.com Assembly Instructions Spring Assist Vertical Vinyl Curtain Door Projection Mount Valued Shaver Customer: We
More informationFD 150 Document Signer
FD 150 Document Signer OPERATOR MANUAL FIRST EDITION Thank you for purchasing the Formax FD 150 Document Signer The FD 150 has been tested and found to comply with the limits for a Class A digital device
More informationInstallation Instructions
COLONY/COLONY SOFT Bidet Faucet and Transfer Valve with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a feature found only on American Standard
More informationHARNESS KIT F INSTALLATION INSTRUCTIONS. Vehicle: Mazda RX-8 Parts number F CFZ (ipod integration module) C9F4 V6 029 (Harness Kit F)
GENUINE ipod INTEGRATION MODULE HARNESS KIT F INSTALLATION INSTRUCTIONS Vehicle: Mazda RX-8 Parts numberf197 79 CFZ (ipod integration module) C9F4 V6 029 (Harness Kit F) Thank you for purchasing a genuine
More informationUSER MANUAL Edition
USER MANUAL Edition 2 2014 CONTENTS Safety guidelines Transportation Unfolding and folding Tilt in space operation Seat depth and pelvic support adjustment Footrest adjustment Fitting optional accessories
More informationVHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate
3875 Cypress Drive Petaluma, CA 94954 800.228.2555 +1.707.773.1100 Fax 707.773.1180 www.gcx.com VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate (Refer to qualified
More informationASSEMBLY INSTRUCTIONS / OWNERS MANUAL AIR BIKE AB-1
AIR BIKE AB- ASSEMBLY INSTRUCTIONS / OWNERS MANUAL IMPORTANT : READ ALL ASSEMBLY INSTRUCTIONS AND SAFETY PRECAUTIONS BEFORE USING THIS PRODUCT. REFERENCE ALL SAFETY GUIDELINES AND WARNING LABELS. RETAIN
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory Application Publications No. AII 24307 SYSTEM 2003 ELEMENT Issue Date DEC 2002 NOTE: An optional keyless entry system (sold seperately) must be installed before you
More informationUniversal Lane. Installation and Maintenance Manual IMPORTANT PRODUCT LIABILITY INFORMATION
Universal Lane Installation and Maintenance Manual IMPORTANT PRODUCT LIABILITY INFORMATION READ ALL INSTRUCTIONS BEFORE PROCEEDING WITH ASSEMBLY. VITAL PRODUCT INFORMATION PERTAINING TO PROPER SETUP, INSTALLATION,
More informationISO FM Made in the U.S.A
This manual has been prepared for the owners and operators of the ARMEDICA AM-Series Mat Tables. It contains installation instructions, precautionary instructions and maintenance procedures for the following
More informationSUNNY PRO INDOOR CYCLING BIKE
SUNNY PRO INDOOR CYCLING BIKE SF-B901 USER MANUAL IMPORTANT! Please retain owner s manual for maintenance and adjustment instructions. Your satisfaction is very important to us, PLEASE DO NOT RETURN UNTIL
More informationPERFORM THE FOLLOWING SAFETY CHECK DAILY:
FITNESS Introduction We at Vectra Fitness appreciate your selection of our product for your fitness program, and invite your questions and comments. We're sure that you ll be pleased with your new Vectra
More informationPRO INDOOR CYCLING BIKE
PRO INDOOR CYCLING BIKE SF-B901 USER MANUAL IMPORTANT! Please retain owner s manual for maintenance and adjustment instructions. Your satisfaction is very important to us, PLEASE DO NOT RETURN UNTIL YOU
More informationOCTA FLUORESCENT 7 SOCKET FIXTURE
OCTA FLUORESCENT 7 SOCKET FIXTURE OC-OF7 Bulbs are not included. INTRODUCTION Thank you for choosing the Raya Octa Fluorescent 7 Socket Fixture. Using Edison-base compact fluorescent lamps (CFL), this
More informationUSER MANUAL. Celesta and. Clodagh Gemini. Celesta. Clodagh Gemini
USER MANUAL Celesta and Clodagh Gemini Celesta Clodagh Gemini www.oakworks.com 717.235.6807 2014 Oakworks, Inc. Notice All rights are reserved. No part of this document may be photocopied, reproduced or
More informationLED-HL2-CMP LED Headlight System Operation Manual
LED-HL2-CMP LED Headlight System Operation Manual Manufactured for: Cardio Medical Products, Inc. 385 Franklin Avenue, Suite L Rockaway, NJ 07866 USA Customer Service: 800-227-3633 info@cardiomedicalproducts.com
More information