ACCUTECT Lightning Protection Networks

Size: px
Start display at page:

Download "ACCUTECT Lightning Protection Networks"

Transcription

1 645 Russell Street Batesburg, SC Service Manual 6486 ACCUTECT Lightning Protection Networks N N N Field Installation and Test Procedure May, , Union Switch & Signal Inc. Printed in USA An ANSALDO Signal Company

2 REVISION HISTORY Original Publication November, 1996 Revision May, 2001

3 TABLE OF CONTENTS Section Topic Page 1 GENERAL INFORMATION INTRODUCTION R.A.I.L. Team and Technical Support INSTALLATION AND TESTING Tools Required Mechanical Mounting Connecting the LPN to the Main Power Source Connecting the Power to Individual ACCUTECTs Testing the Power Connection ACCUTECT Signal Wire Connection Testing the Signal Wire Integrity TROUBLESHOOTING Equipment Required Testing the B24WD/N23WD feed Testing the signal line protection List of Figures Figure Front View of the ACCUTECT Lightning Protection Network (LPN) Figure Wiring diagram showing the connections for a 1-way Lightning Protection Network (N ) Figure 2-2 Wiring diagram showing the connections for a 2-way Lightning Protection Network (N ) Figure 2-3 Wiring diagram showing connections for a 3-way Lightning Protection Network (N ) List of Tables Table 1-1 Assembly and Subassembly Part Number References SM6486 (05/01) i

4 This page is intentionally blank. ii SM6486 (05/01)

5 SECTION 1: GENERAL INFORMATION 1.1 INTRODUCTION The N , N and N are self-contained lightning protection networks designed to protect 1, 2 or 3 ACCUTECT wheel detectors, respectively. These part numbers refer to complete assemblies and include a 12-way AREMA terminal block, a steel mounting plate, a printed circuit board and all AREMA hardware necessary for wiring. A bag containing the hardware needed to mount the assembly into a wayside junction box is also included. Once these assemblies are installed, the terminal block and steel plate should never require changing under normal service conditions. The printed circuit board can easily be removed from the terminal block, should it need replacing. The piece numbers for individual boards are clearly marked on the white board tag. The assembly and subassembly part numbers and their functions are summarized in Table 1-1. Complete Assembly including Mounting Plate and Terminal Block Encapsulated Printed Circuit Board Assembly Only Number of ACCUTECT Wheel Detectors that can be Protected N N N N N N TABLE 1-1. ASSEMBLY AND SUBASSEMBLY PART NUMBER REFERENCES With the except of the printed circuit boards listed above, replacement parts are not available for the ACCUTECT LPN. Refer to Section 3: Troubleshooting to verify the integrity of the units. Please contact your sales or customer service representative for ordering information should the unit be determined to be inoperable. The lightning protection network (LPN) assemblies are designed to fit in standard classyard, wayside junction boxes with a single 12-way AREMA terminal block mounted on one side of the terminal block support bracket. The LPN assembly mounts on the side of the terminal board support bracket that is opposite the side where the existing terminal block is mounted. To determine how many ACCUTECTs can be protected by a particular LPN, refer to a tag located on the front of the LPN assembly (refer to Figure 1-1). One of three squares will be marked to indicate whether one, two or three ACCUTECTs can be protected by the LPN. This can also be quickly determined by looking at the AREMA hardware on the terminal block (there are only twelve terminals on the block, and they are divided into three groups with four terminals in each group). Looking left to right, if only the first group of terminals has all the necessary AREMA hardware installed, then only one ACCUTECT can be protected. Similarly, if the first and second groups of terminals have all the necessary AREMA hardware installed, then two ACCUTECTs can be protected. Finally, SM6486 (05/01) 1-1

6 SECTION 1: GENERAL INFORMATION if all 12 terminals are populated with the AREMA hardware, then three ACCUTECTs can be protected by that LPN. FIGURE FRONT VIEW OF THE ACCUTECT LIGHTNING PROTECTION NETWORK (LPN) 1.2 R.A.I.L. TEAM AND TECHNICAL SUPPORT The Rapid Action Information Link (R.A.I.L.) Team is comprised of experienced product and application engineers ready to assist and resolve technical issues concerning any US&S product. Any questions regarding the contents of this Service Manual can be answered by contacting the R.A.I.L. Team via at railteam@switch.com or a toll-free call to SM6486 (05/01)

7 SECTION 2: INSTALLATION AND TESTING 2.1 TOOLS REQUIRED 7/16" Nut-driver AREMA wrench 2.2 MECHANICAL MOUNTING 1. Remove the small plastic bag from the terminal block. The bag should have two hexhead, 1/4-20 x 1/2" bolts and two 1/4" split lock washers. 2. Position the LPN assembly against the support brackets, align the mounting plate with the pre-tapped holes, and secure it to the brackets with the two bolts and lock washers that are provided. 2.3 CONNECTING THE LPN TO THE MAIN POWER SOURCE There are two wires (one red and one black) attached to the LPN circuit board. The red wire is labeled B24WD-MAIN and the black wire is labeled N24WD-MAIN. To bring power to the LPN, these two wires must be connected to the main 24 VDC feed coming to the junction box. This 24 VDC is accessed from the AREMA terminal strip on the opposite side of the support bracket. It is important to connect the main power in the correct polarity, although the LPN is protected internally from reverse power applications. RED is positive and BLACK is negative. The protected individual ACCUTECT B24WD and N24WD feeds are then distributed from the LPN. NOTE Neatly dress all wiring to avoid the possibility of pinching the wires under the junction box lid. WARNING For correct polarity, RED wire is positive and BLACK wire is negative. Do not reverse the polarity of the connections to the ACCUTECT detector head, otherwise damage to the ACCUTECT detector head may occur. 2.4 CONNECTING POWER TO INDIVIDUAL ACCUTECTS (REFER TO FIGURES 1-1, 2-1, 2-2 AND 2-3) Silk-screened labels appear on the printed circuit board in the area around the twelve AREMA terminals. This circuit board is divided into three sections: ACCUTECT #1, ACCUTECT #2, and ACCUTECT #3. Each section contains a group of four AREMA terminals, as indicated in Figure 1-1. In each of these groups of four terminals, two of the terminals are labeled B24WD and N24WD. These terminals will provide protected 24 VDC power to one ACCUTECT unit. SM6486 (05/01) 2-1

8 SECTION 2: INSTALLATION AND TESTING The power leads going to each of the ACCUTECT Wheel Detectors must be moved from the original AREMA terminal block to the appropriate terminals of the LPN. Examples 1. If a single ACCUTECT is being protected by a 1-way LPN, then 24 VDC power for that ACCUTECT will come from the B24WD and N24WD terminals in the ACCUTECT #1 group (refer to Figures 1-1 and 2-1). 2. If two ACCUTECTs are being protected by a 2-way LPN, then the 24 VDC power will come to each ACCUTECT separately from the B24WD and N24WD terminals in the ACCUTECT #1 and ACCUTECT #2 groups, respectively (refer to Figures 1-1 and 2-2). 3. If three ACCUTECTs are being protected by a 3-way LPN, then the 24 VDC power for three units will come from the B24WD and N24WD terminals in the ACCUTECT #1, ACCUTECT #2, and ACCUTECT #3 groups, respectively (refer to Figures 1-1 and 2-3). NOTE The power leads going to each of the ACCUTECT Wheel Detectors must be moved from the original AREMA terminal block to the appropriate terminals of the LPN. 2-2 SM6486 (05/01)

9 SECTION 2: INSTALLATION AND TESTING FIGURE WIRING DIAGRAM SHOWING THE CONNECTIONS FOR A 1-WAY LIGHTNING PROTECTION NETWORK (N ) SM6486 (05/01) 2-3

10 SECTION 2: INSTALLATION AND TESTING FIGURE WIRING DIAGRAM SHOWING THE CONNECTIONS FOR A 2-WAY LIGHTNING PROTECTION NETWORK (N ) 2-4 SM6486 (05/01)

11 SECTION 2: INSTALLATION AND TESTING FIGURE WIRING DIAGRAM SHOWING CONNECTIONS FOR A 3-WAY LIGHTNING PROTECTION NETWORK (N ) SM6486 (05/01) 2-5

12 SECTION 2: INSTALLATION AND TESTING 2.5 TESTING THE POWER CONNECTIONS After completing the 24 VDC power distribution wiring, use a voltmeter to measure the voltage across the B24WD and N24WD terminals of the protected groups. That is, for a 1-way LPN, measure the voltage across the B24WD and N24WD terminals of the ACCUTECT #1 group, for a 2-way LPN, measure the voltage across the B24WD and N24WD terminals of the ACCUTECT #1 and ACCUTECT #2 groups. For a 3-way LPN, measure the voltage across the B24WD and N24WD terminals of the ACCUTECT #1, ACCUTECT #2, and ACCUTECT #3 groups. NOTE There is insertion loss in the LPN which will drop about two volts when a wheel is detected. The voltage measured at the B24WD and N24WD terminals of the LPN should not measure below 21 volts when a wheel is detected. If the voltage drops below 21 volts, adjust the main 24 volt power supply to provide at least 21 volts when a wheel is detected. 2.6 ACCUTECT SIGNAL WIRE CONNECTION The previous section described the silk-screened labels on the circuit board and the ACCUTECT #1, ACCUTECT #2, and ACCUTECT #3 terminal groups and the 24 VDC power distribution terminals in each group. This section describes steps for protecting the ACCUTECT signal wires. In each ACCUTECT group of four terminals, there are two terminals labeled 1X and 2X. These terminals are where the ACCUTECT signal wires (coming from the wheel detector itself) and the wires carrying this signal back to the computer room are to be connected. Refer to Figures 1-1 through TESTING THE SIGNAL WIRE INTEGRITY The integrity of the signal wires is to be checked by artificially triggering the ACCUTECT detector head (out at the rails) and verifying with someone in the control room that the computer has indicated that the detector has triggered. The wheel detector head can be artificially triggered by placing a piece of steel against the side of the detector closest to the rail (the internal magnet will pull the steel to it) and then pull the steel away. 2-6 SM6486 (05/01)

13 SECTION 3: TROUBLESHOOTING If an LPN unit is suspected of failure, use the following procedures to verify operation. 3.1 EQUIPMENT REQUIRED Simpson 260 Analyzer or equivalent AREMA Wrench 3.2 TESTING THE B24WD / N24WD FEED 1. Locate the junction box that services the suspected LPN or ACCUTECT unit. 2. Configure the Simpson 260 as a voltmeter. Measure the voltage across the B24WD- MAIN and N24WD-MAIN terminals, which is where the LPNs red and black wires are connected. The voltage should be between 21 and 27 volts. 3. If main VDC power is being supplied to the LPN, check the individual B24WD / N24WD feeds leaving the LPNs. a. For a 1-way LPN, measure the voltage across the B24WD / N24WD in the ACCUTECT #1 group of terminals. The voltage should be at least 21 volts, although the ACCUTECTs will operate with a voltage as low as 18 volts. b. For a 2-way LPN, measure the voltage across the B24WD/ N24WD in the ACCUTECT #1 and ACCUTECT #2 groups of terminals. The voltages should be at least 21 volts, although the ACCUTECTs will operate with a voltage as low as 18 volts. c. For a 3-way LPN, measure the voltage across the B24WD / N24WD in the ACCUTECT #1, ACCUTECT #2, and ACCUTECT #3 groups of terminals. The voltages should be at least 21 volts, although the ACCUTECTs will operate with a voltage as low as 18 volts. 4. In most cases, a failure of the B24WD/N24WD feed circuit(s) will result in a very low output voltage. 3.3 TESTING THE SIGNAL LINE PROTECTION 1. If the signal line protection is suspected of failure, disconnect the corresponding ACCUTECT signal lines (including the wires from the ACCUTECT itself and the wires to the computer room) from the 1X and 2X terminals of the LPN. 2. Set the Simpson Analyzer to measure Ohms on the Rx 100 scale. 3. Connect the Simpson test leads across the suspect 1X and 2X terminals. The meter should indicate an open circuit. 4. Reverse the polarity of the Simpson connection. The meter should indicate an open circuit. NOTE A failure of the signal line protection will typically indicate a short circuit or partial short circuit in one or both polarities. SM6486 (05/01) 3-1

14 SECTION 3.0: TROUBLESHOOTING This page is intentionally blank. 3-2 SM6486 (05/01)

15

Digitair End of Train Break-Away on the Fly System

Digitair End of Train Break-Away on the Fly System UNION SWITCH & SIGNAL 645 Russell Street Batesburg, SC 29006 SERVICE MANUAL 7074 Digitair End of Train Break-Away on the Fly System Installation Operation Maintenance November 1998 1998, Union Switch &

More information

OEM Manual. 4042SA Leak Detecting Spill Alarm Instruction manual

OEM Manual. 4042SA Leak Detecting Spill Alarm Instruction manual OEM Manual 4042SA Leak Detecting Spill Alarm Instruction manual 1 These instructions generally describe the installation, operation, and maintenance of, subject equipment. The manufacturer reserves the

More information

SX-16 Nightsun Searchlight Safety and Service Bulletin # SL

SX-16 Nightsun Searchlight Safety and Service Bulletin # SL SX-16 Nightsun Searchlight Safety and Service Bulletin # SL 0898-02 Issue Date: 09/25/98 Amended Date: 02/09/06 Subject: SX-16 Nightsun Junction Box Wiring Modification Affected Products: All SX-16 Nightsun

More information

TROUBLESHOOTING GENERATOR UNITS

TROUBLESHOOTING GENERATOR UNITS TROUBLESHOOTING GENERATOR UNITS Figure 3.17 Troubleshooting Flow Chart For Direct Excited (Brush Type) Generators or later. 68 Troubleshooting Direct Excited (Brush Type) Generators Refer to Figure 3.17

More information

MAINTENANCE NOTICE. YM-2000 Switch Machine Motor Cutout Switch Adjustment. (US&S Part No. N , N , N )

MAINTENANCE NOTICE. YM-2000 Switch Machine Motor Cutout Switch Adjustment. (US&S Part No. N , N , N ) Union Switch & Signal Inc., an Ansaldo Signal company 1000 Technology Drive, Pittsburgh, PA 15219 ÃÃÃ5XVVHOOÃ6WUHHWÃBatesburg, SC 29006 MN-02-001 MAINTENANCE NOTICE YM-2000 Switch Machine (US&S Part No.

More information

CHASSIS TECH TIPS. Subject: VOLTAGE DROP TEST

CHASSIS TECH TIPS. Subject: VOLTAGE DROP TEST Subject: VOLTAGE DROP TEST 1. RELEVANT MODELS: All Hino Models (Cab over and Conventional) 2. COMPLAINT: Electrical failure 3. CAUSE/CONDITION: High resistance and poor connections 4. CORRECTION: Proper

More information

M-23A, M-23B, M-3 and Low-Profile M-3 Electric Switch Machines

M-23A, M-23B, M-3 and Low-Profile M-3 Electric Switch Machines Switch Machines and Associated Equipment Ansaldo STS USA M-23A, M-23B, M-3 and Low-Profile M-3 Electric Switch Machines ASTS USA s style M Electric Switch Machines are rugged, reliable, units designed

More information

Chapter 7. The Series-Parallel Network

Chapter 7. The Series-Parallel Network Chapter 7 Series-Parallel Circuits The Series-Parallel Network Branch Part of a circuit that can be simplified into two terminals Components between these two terminals Resistors, voltage sources, or other

More information

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR 125-5 P/N 9168800100 Publication: 9168800990 Revision: J 03/09 INTRODUCTION This instruction manual provides information about the operation and installation

More information

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved DRM TM DRM-HP TM Electronic Dynamo Regulator INSTRUCTION MANUAL COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved INTRODUCTION The Clover Systems DRM is a state-of-the art all-electronic voltage and current

More information

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved DR310 TM Electronic Dynamo Regulator INSTRUCTION MANUAL COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved INTRODUCTION The Clover Systems DR310 is an allelectronic voltage and current regulator for dynamos

More information

BATTERY DISCONNECT SERVICE MANUAL

BATTERY DISCONNECT SERVICE MANUAL Battery Disconnect provides a simple and safe means of remotely disconnecting batteries of an RV or boat. With a touch of a remote switch, the batteries will be completely disconnected, preventing unwanted

More information

MGB Alternator Conversion Installation Instructions For MGA & 1962 to 1967 MGB

MGB Alternator Conversion Installation Instructions For MGA & 1962 to 1967 MGB MGB Alternator Conversion Installation Instructions For MGA & 1962 to 1967 MGB PART# 130-078, 130-088, 130-098 440 Rutherford St. Goleta, CA 93117 1-800-642-8295 FAX 805-692-2525 www.mossmotors.com Scan

More information

ONE TOUCH CONTROL BOX

ONE TOUCH CONTROL BOX ONE TOUCH CONTROL BOX CONVERSION KIT INSTRUCTIONS REMOVAL, INSTALLATION, OPERATION, AND REMOTE CONTROL PROGRAMMING THUNDERSTONE PART #101322 REVISION A JULY 14 TH 2016 2 P a g e INSTALLING THE THUNDER

More information

INSTALLATION MANUAL. with ILLUSTRATED PARTS LIST. covering. Fuel Tank Replacement Kit. Part Number

INSTALLATION MANUAL. with ILLUSTRATED PARTS LIST. covering. Fuel Tank Replacement Kit. Part Number TO-237 430577-29 040196 INSTALLATION MANUAL with ILLUSTRATED PARTS LIST covering Fuel Tank Replacement Kit Part Number 285788 manufactured by HOBART BROTHERS COMPANY Ground Power Division TROY,OHIO45373

More information

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number: INSTRUCTION MANUAL FOR VOLTAGE REGULATOR Model: APR 125-5 Part Number: 9 1688 00 100 Publication Number: 9 1688 00 990 Revision H: 07/2001 CONTENTS SECTION 1 GENERAL INFORMATION...1-1 DESCRIPTION... 1-1

More information

( Versions Available)

( Versions Available) STYLE 494 ELECTRIC LADDER PIPE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS ( Versions Available) The following is intended to provide the basic instructions for installation, operating and maintenance

More information

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved DRM TM DRM-HP TM Electronic Dynamo Regulator INSTRUCTION MANUAL COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved INTRODUCTION The Clover Systems DRM is a state-of-the art all-electronic voltage and current

More information

Exercise 2: Series-Opposing DC Sources

Exercise 2: Series-Opposing DC Sources Exercise 2: Series-Opposing DC Sources EXERCISE OBJECTIVE When you have completed this exercise, you will be able to determine voltage by using series-opposing power connections. You will verify your results

More information

3143 Production Drive Fairfeild, Ohio Model HA-45. Installation and Service Manual

3143 Production Drive Fairfeild, Ohio Model HA-45. Installation and Service Manual 3143 Production DriveFairfeild, Ohio 45014513-874-3733 Model HA-45 Installation and Service Manual 3143 Production DriveFairfeild, Ohio 45014513-874-3733 Model HA-45 Installation and Service Manual Table

More information

3143 Production Drive Fairfeild, Ohio Model HA Installation and Service Manual

3143 Production Drive Fairfeild, Ohio Model HA Installation and Service Manual 3143 Production Drive Fairfeild, Ohio 45014 513-874-3733 Model HA-1000 Installation and Service Manual 3143 Production Drive Fairfeild, Ohio 45014 513-874-3733 Model HA-1000 Installation and Service Manual

More information

LCR Series REVERSING ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

LCR Series REVERSING ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions LCR Series REVERSING ELECTRIC ACTUATORS Installation, Maintenance and Operating Instructions IMO-I1262 11/2008 2 METSO AUTOMATION IMO-I1262 REV. 11/08 Table of Contents 1 GENERAL....................................

More information

2/2/2018 Feed Circuit Test (Starting System) - ALLDATA

2/2/2018 Feed Circuit Test (Starting System) - ALLDATA 2005 Jeep Truck Grand Cherokee 2WD V8-5.7L VIN 2 Vehicle > Starting and Charging > Starting System > Testing and Inspection > Component Tests and General Diagnostics FEED CIRCUIT TEST The starter feed

More information

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market 1 888-323-8755 www.nwlifts.com JEEVES Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter

More information

534HS Pressure Transmitter

534HS Pressure Transmitter These instructions provide information for installation, process connection, electrical connection and field calibration of SOR 534HS Pressure Transmitters. The 534HS Pressure Transmitter consists of a

More information

Troubleshooting Bosch Proportional Valves

Troubleshooting Bosch Proportional Valves Troubleshooting Bosch Proportional Valves An Informative Webinar Developed by GPM Hydraulic Consulting, Inc. Instructed By Copyright, 2009 GPM Hydraulic Consulting, Inc. TABLE OF CONTENTS Bosch Valves

More information

INSTALLATION MANUAL & OPERATING INSTRUCTIONS

INSTALLATION MANUAL & OPERATING INSTRUCTIONS INSTALLATION MANUAL & OPERATING INSTRUCTIONS SIGALARM MODEL 210 PMB 405; West SR 46 Sanford, FL 32771 (800) 589-3769 (407) 328-9479 Fax: (407) 328-5889 Email:info@sigalarminc.com Internet: http://www.sigalarminc.com

More information

UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by

UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by Model 348 UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by FLIGHT SYSTEMS www.flightsystems.com Description INSTALLATION and ADJUSTMENT INSTRUCTIONS The Model 348 Universal Regulator is a fully encapsulated

More information

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus: 1.0 Introduction: This probe is designed to provide an additional help to automotive technicians in trouble shooting of electrical circuits problems in the car. Apart from using the normal multi tester,

More information

General Information. Notations and Conventions. Compatibility Check. Kit Description. Call-Outs. Part Lists Great Plains Manufacturing, Inc.

General Information. Notations and Conventions. Compatibility Check. Kit Description. Call-Outs. Part Lists Great Plains Manufacturing, Inc. Part Lists Great Plains Manufacturing, Inc. 1 Installation Instructions Loup Shaft Monitor Used with Drill models: Compatible with most 1995 and later, two- and three-box drills with 5 8 -inch square main

More information

CP /240-MC4 User Manual

CP /240-MC4 User Manual CP-250-60-208/240-MC4 User Manual Chilicon Power LLC Dec 2015 1 CONTENTS Important Safety Instructions... 3 Safety Instructions... 3 CP-250 Microinverter System Introduction... 4 Inverter Label Information...

More information

Installation & Service Manual. Frameworx Tel-E-Foul. July 2005 /

Installation & Service Manual. Frameworx Tel-E-Foul. July 2005 / Installation & Service Manual Frameworx Tel-E-Foul July 2005 / 53-900676-000 Frameworx Tel-E-Foul Installation Manual July 2005 by the Brunswick Bowling & Billiards Corporation. All rights reserved. Past

More information

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES PART NUMBER: 250-9631 GENERAL APPLICABILITY THIS CRUISE WAS TESTED AND VERIFIED ON: ALL MODELS (AT/MT) RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES KIT CONTENTS/SERVICE PARTS ITEM QTY

More information

PV-250 Track Relay. Operating Values For Hz PV-250 Track Relay With 115 Volt Local 440 Turn Track Coil

PV-250 Track Relay. Operating Values For Hz PV-250 Track Relay With 115 Volt Local 440 Turn Track Coil [UNION SWITCH & SIGNAL IL~j 645 Russell Street Service Manual 4574-M Batesburg, SC 29006 PV-250 Track Relay Operating Values For 90183.3 Hz PV-250 Track Relay With 115 Volt Local 440 Turn Track Coil Installation,

More information

Chapter 26 DC Circuits

Chapter 26 DC Circuits Chapter 26 DC Circuits Electric circuit needs battery or generator to produce current these are called sources of emf. Battery is a nearly constant voltage source, but does have a small internal resistance,

More information

Chapter 26 DC Circuits. Copyright 2009 Pearson Education, Inc.

Chapter 26 DC Circuits. Copyright 2009 Pearson Education, Inc. Chapter 26 DC Circuits 26-1 EMF and Terminal Voltage Electric circuit needs battery or generator to produce current these are called sources of emf. Battery is a nearly constant voltage source, but does

More information

APPLICATION NOTE QuickStick 100 Power Cable Sizing and Selection

APPLICATION NOTE QuickStick 100 Power Cable Sizing and Selection APPLICATION NOTE QuickStick 100 Power Cable Sizing and Selection Purpose This document will provide an introduction to power supply cables and selecting a power cabling architecture for a QuickStick 100

More information

SPACESAVER EC-300 A ELECTRICS

SPACESAVER EC-300 A ELECTRICS INSTALLATION INSTRUCTIONS SPACESAVER EC-300 A ELECTRICS SECTION I TOP MOUNTED ELECTRICS SECTION II FACE PANEL MOUNTED ELECTRICS SECTION III ZFS INSTALLATION INSTRUCTIONS This symbol indicates a connection

More information

PP-151. Service Manual 4551 G. An Ansaldo Signal Company. IUNION SWITCH & SIGNALl[fil] Magnetic Stick DC Plug-In Relay

PP-151. Service Manual 4551 G. An Ansaldo Signal Company. IUNION SWITCH & SIGNALl[fil] Magnetic Stick DC Plug-In Relay IUNION SWITCH & SIGNALl[fil] 645 Russell Street Batesburg, SC 29006 Service Manual 4551 G PP-151 Magnetic Stick DC Plug-In Relay October, 1980 D-79-100-2306-5 1980, Union Switch & Signal Inc. Printed in

More information

Product Guide: Series III Pump Control Board Set (RoHS)

Product Guide: Series III Pump Control Board Set (RoHS) revised 04/08/10 Description: The Series III Pump Control Board Set provides motor drive and pump control for a wide assortment of pumps from Scientific Systems, Inc. The assembly consists of two circuit

More information

V cloud softlight small mobile ( V) installation guide

V cloud softlight small mobile ( V) installation guide V170704 cloud softlight small mobile (110-120V) installation guide small cloud mobile anatomy dimmable hardwire transformer canopy plate main electrical wire main anodized aluminum mobile structure small

More information

Informational Distribution List:

Informational Distribution List: Technical Bulletin 2017 Southern Technologies Corporation (STC). All rights reserved. Bulletin Number: TB-2017198-BW01 Date Published: 07/17/2017 Summary: Instructions for mounting, aligning and setting

More information

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER 3714 Kinnear Place Saskatoon, SK Canada S7P 0A6 Ph: (306) 373-5505 Fx: (306) 374-2245 www.littelfuse.com/relayscontrols SE-3SCR-LM MANUAL MOTOR LOAD MANAGER MARCH 5, 2013 REVISION 4 MOTOR LOAD MANAGER

More information

Using the PST-2000 with Peterbilt Trucks. Document Number B

Using the PST-2000 with Peterbilt Trucks. Document Number B Using the PST-2000 with Peterbilt Trucks Document Number Every effort has been made to keep the information in this document current and accurate as of the date of publication or revision. However, no

More information

ELECTRICAL POWER-STATIC INVERTER - BRIDGE ASSEMBLY R170 RELOCATION

ELECTRICAL POWER-STATIC INVERTER - BRIDGE ASSEMBLY R170 RELOCATION ELECTRICAL POWER-STATIC INVERTER - BRIDGE ASSEMBLY R170 RELOCATION I PLANNING INFORMATION A. Effectivity- Static Inverter Part Number 1-002-0102-0265, (Boeing P/N S282T004-5), Model 1C1000-1A, Mod Levels

More information

Features IN THIS CHAPTER

Features IN THIS CHAPTER CHAPTER THREE 3Special Features IN THIS CHAPTER Motor Braking Regeneration Solutions Sharing the Power Bus: V Bus+ and V Bus- Current Foldback (I T Limit) Front Panel Test Points Resolver Alignment ➂ Special

More information

12/05/2012 Lockup Co-Pilot Instructions INST. Installation Manual v1.6: Dodge 68RFE Automatic Transmission

12/05/2012 Lockup Co-Pilot Instructions INST. Installation Manual v1.6: Dodge 68RFE Automatic Transmission Installation Manual v1.6: 2007.5-09 Dodge 68RFE Automatic Transmission Please read all instructions before the installation of the ATS Co-Pilot Thank you for purchasing the ATS Co-Pilot transmission management

More information

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords. Optima ETF-500 ETF-500 TO MOUNT FAUCET ON A SURFACE BETWEEN 0.1 (10 MM) AND 1.00 (25 MM) THICK, USE THE HARDWARE SHOWN BELOW. 7 1B 3B 1A 2 3A 5 6 11 10 5 9 PARTS LIST ETF-500 FAUCET Item No. Code No. Part

More information

Yaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0.

Yaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0. Yaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW) Page 1 Introduction This manual is divided into three sections:

More information

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES PART NUMBER: 250-9627 GENERAL APPLICABILITY THIS CRUISE WAS TESTED AND VERIFIED ON: ALL MODELS (AT/MT) RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES KIT CONTENTS/SERVICE PARTS ITEM QTY

More information

V cloud softlight medium mobile ( V) installation guide

V cloud softlight medium mobile ( V) installation guide V170704 cloud softlight medium mobile (110-120V) installation guide medium cloud mobile anatomy dimmable hardwire transformer canopy plate anodized aluminum mobile structure main large cloud pendant main

More information

Allen-Bradley HP Inverting Fault Circuit Breaker Kit

Allen-Bradley HP Inverting Fault Circuit Breaker Kit Allen-Bradley 1397 400-600HP Inverting Fault Circuit Breaker Kit Cat. Nos. 1397-IFB600 What This Option Provides This option is intended to be applied to regenerative 1397 drives with high inertia loads.

More information

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable Chilicon Power Aug 2016 1 CONTENTS CP-250E Microinverter System... 3 The CP-100 Cortex Gateway... 3 Important Safety Information... 4 Inverter

More information

SERVICE TOOL CONTENTS

SERVICE TOOL CONTENTS 09-13 TOYOTA TACOMA PART NUMBER: 250-1836 CRUISE CONTROL KIT 1 3 SERVICE TOOL CONTENTS ITEM QTY DESCRIPTION PART NUMBER BASE KIT CONTENTS ITEM QTY DESCRIPTION 1 1 CONTROL SWITCH ASSEMBLY 2 2 SCREWS (M5)

More information

Electrical Measuring Instruments

Electrical Measuring Instruments UNIT 12 Electrical Measuring Instruments Learning Objectives After studying this unit, the student will be able Understand different measuring instruments used in electricity Understand the working of

More information

SERVICE MANUAL for. Engine-to-Generator. Part Number used on. John Deere Engine Driven Aircraft Ground Power Single-Bearing Generator Sets

SERVICE MANUAL for. Engine-to-Generator. Part Number used on. John Deere Engine Driven Aircraft Ground Power Single-Bearing Generator Sets TO-216 SERVICE MANUAL for Engine-to-Generator FLEXIBLE COUPLING Part Number 181267 used on John Deere Engine Driven Aircraft Ground Power Single-Bearing Generator Sets manufactured by HOBART BROTHERS COMPANY

More information

Condensed Version of Operator s Manual For The VI/VP700 Series Flowmeter and VI800 Series Flowmeter

Condensed Version of Operator s Manual For The VI/VP700 Series Flowmeter and VI800 Series Flowmeter Condensed Version of Operator s Manual For The VI/VP700 Series Flowmeter and VI800 Series Flowmeter Warranty Agreement J-TEC Associates warrants this product to be in good working order for a period of

More information

RODIX, INC. FC-40-PLC Plus Series Control Troubleshooting Guide for Circuit Board P/Ns and

RODIX, INC. FC-40-PLC Plus Series Control Troubleshooting Guide for Circuit Board P/Ns and RODIX, INC. FC-40-PLC Plus Series Control Troubleshooting Guide for Circuit Board P/Ns 24-488 and 24-489 Control must be connected to a known GOOD LOAD prior to testing Problem: No output from the control

More information

Circuits-Circuit Analysis

Circuits-Circuit Analysis Base your answers to questions 1 through 3 on the information and diagram below. 4. A 9-volt battery is connected to a 4-ohm resistor and a 5-ohm resistor as shown in the diagram below. A 3.0-ohm resistor,

More information

TRAIL CHARGER with EXTENDER and COMBO NOSE BOX

TRAIL CHARGER with EXTENDER and COMBO NOSE BOX TRAIL CHARGER with EXTENDER and COMBO NOSE BOX 284424 01 Version 1.02 03/14/2011 Owners Manual Operation Installation Wiring Diagram Troubleshooting Parts Breakdown 1 GENERAL OPERATION PROBLEM On applications

More information

Experiment 3: Ohm s Law; Electric Power. Don t take circuits apart until the instructor says you don't need to double-check anything.

Experiment 3: Ohm s Law; Electric Power. Don t take circuits apart until the instructor says you don't need to double-check anything. Experiment 3: Ohm s Law; Electric Power. How to use the digital meters: You have already used these for DC volts; turn the dial to "DCA" instead to get DC amps. If the meter has more than two connectors,

More information

Using the PST-2000 with Freightliner Trucks. Document Number B

Using the PST-2000 with Freightliner Trucks. Document Number B Using the PST-2000 with Freightliner Trucks Document Number Every effort has been made to keep the information in this document current and accurate as of the date of publication or revision. However,

More information

FiveFish Studios PSU-2448Plus+ Assembly Guide

FiveFish Studios PSU-2448Plus+ Assembly Guide FiveFish Studios PSU-2448Plus+ Assembly Guide Copyright 2015-2017 FiveFish Audio Revision 1.02-20171105 No part of this document may be reproduced, either mechanically or electronically, posted online

More information

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual Combiner Box Installation & Operations Manual SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual TABLE OF CONTENTS Notices and Safety Precautions Pages 1-2 Combiner

More information

CHARGING SYSTEM 7.7 GENERAL TROUBLESHOOTING. Alternator. Voltage Regulator. Battery. Wiring. Voltage Regulator Inspection HOME

CHARGING SYSTEM 7.7 GENERAL TROUBLESHOOTING. Alternator. Voltage Regulator. Battery. Wiring. Voltage Regulator Inspection HOME CHARGING SYSTEM 7.7 GENERAL 8740 The charging system consists of the alternator and regulator. Charging system circuits are shown in Figure 7-5. Never install accessory wiring between battery post and

More information

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS CRECOMZR05B00 CRECOMZR055B00 VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS TABLE OF CONTENTS PACKAGE USAGE...1 SAFETY CONSIDERATIONS...1 PACKAGE CONTENTS...1 GENERAL...2

More information

ALTERNATING CURRENT - PART 1

ALTERNATING CURRENT - PART 1 Reading 9 Ron Bertrand VK2DQ http://www.radioelectronicschool.com ALTERNATING CURRENT - PART 1 This is a very important topic. You may be thinking that when I speak of alternating current (AC), I am talking

More information

Ultrasonic Two-Wire Point Level Control

Ultrasonic Two-Wire Point Level Control Ultrasonic Two-Wire Point Level Control General Instructions The Ultrasonic Point Level Control indicates liquid presence/absence within a sensor cavity. Two piezoelectric crystals face each other across

More information

Stay-IN-Play with Panic Stop Braking

Stay-IN-Play with Panic Stop Braking INSTALLATION INSTRUCTIONS TOWED VEHICLE BRAKING SYSTEM Stay-IN-Play with Panic Stop Braking SMI Manufacturing, Inc. P.O. Box 14040 Evansville, IN 47728 1-800-893-3763 www.smibrake.com SIP0906 Model SIP0603

More information

Essential Electricity Homework Exercise 1

Essential Electricity Homework Exercise 1 Homework Exercise 1 1. For each of the following electrical symbols, copy the symbol into you jotter and label it using the words below. Word bank resistor, voltmeter, battery, ammeter, bulb V A 2. State

More information

11712 Jefferson Ave, Suite C-#446 Newport News, VA Website: Office (757)

11712 Jefferson Ave, Suite C-#446 Newport News, VA Website:   Office (757) 11712 Jefferson Ave, Suite C-#446 Newport News, VA 23606 E-mail: mpusupport@allteksystems.com Website: www.allteksystems.com Office (757) 546-0742 Manual and Users Guide Version B.4 2 Thank you for purchasing

More information

IMPORTANT! READ BEFORE INSTALLING!

IMPORTANT! READ BEFORE INSTALLING! 1360 Redwood Way, Suite A Petaluma, CA. 94954 TEL: (707) 763-7799 Toll free in the USA (800) 767-9543 FAX (707) 763-2631 www.xandexsemi.com EMAIL: info@xandex.com Instructions for Xandex Pneumatic Controller

More information

Derailment Detector Assembly

Derailment Detector Assembly Derailment Detector Assembly Every attempt has been made to ensure that this documentation is as accurate and up-to-date as possible. However, Vertical Express assumes no liability for consequences, directly

More information

TI23 Pre-Instructional Survey

TI23 Pre-Instructional Survey TI23 Pre-Instructional Survey Name: Date: 1. Identify the balloon contents that represent the relationship between the three electrical measurements as they relate to Ohm s Law. 2. Which of the statements

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

Installation Manual. Frameworx Tel-E-Foul. September 2017 /

Installation Manual. Frameworx Tel-E-Foul. September 2017 / Installation Manual Frameworx Tel-E-Foul September 2017 / 53-900676-000 Frameworx Tel-E-Foul Installation Manual September 2017 by the Brunswick Bowling Products. All rights reserved. Past Revisions: March

More information

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES PART NUMBER: 250-9625 GENERAL APPLICABILITY THIS CRUISE WAS TESTED AND VERIFIED ON: ALL MODELS RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES KIT CONTENTS/SERVICE PARTS ITEM QTY DESCRIPTION

More information

Clutch Control. PN: November 2013 Rev E 1

Clutch Control. PN: November 2013 Rev E 1 NOTE: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Module Kit 4100533 1 Cable Installation Kit 2000901-1 1 Alcohol swab packet 2002811 2

More information

NPD to FID conversion on SRI 8610C or 310C GC July2012

NPD to FID conversion on SRI 8610C or 310C GC July2012 July2012 Unplug GC from wall power The SRI 8610C GC is shown at right. The NPD detector will be located at the right side of the column oven covered with an insulated aluminum box. Remove the single screw

More information

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL Battery Management Innovation For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL ! CAUTION Because of the possibility of personal injury, always use extreme caution

More information

Installation Tips for your Crimestopper/ProStart Remote Start system (for GM vehicles) v1.01 updated 2/27/2012

Installation Tips for your Crimestopper/ProStart Remote Start system (for GM vehicles) v1.01 updated 2/27/2012 Installation Tips for your Crimestopper/ProStart Remote Start system (for GM vehicles) v1.01 updated 2/27/2012 Thank you for purchasing your remote start from MyPushcart.com - an industry leader in providing

More information

Porta-Tronic. Portable Scales. INSTALLATION GUIDE Version 2.0

Porta-Tronic. Portable Scales. INSTALLATION GUIDE Version 2.0 Porta-Tronic Portable Scales INSTALLATION GUIDE Version 2.0 GSE Porta-Tronic Installation Guide Copyright 2008 GSE. All rights reserved. Published by: GSE 1525 Fairlane Circle Allen Park, MI 48101 www.gse-inc.com

More information

Warm Tiles Troubleshooting. Al & Jed

Warm Tiles Troubleshooting. Al & Jed Warm Tiles Troubleshooting Al & Jed C O N T E N T S DFT Cable Construction (p.1) An overview of how the cable is built and what comprises the cable. Types of Cable Faults (p.4) Discusses the different

More information

Installation Manual v1.0: Dodge 68RFE Automatic Transmission. Please read all instructions before the installation of the ATS Co-Pilot

Installation Manual v1.0: Dodge 68RFE Automatic Transmission. Please read all instructions before the installation of the ATS Co-Pilot 09/30/11 601-900-2356-INST Installation Manual v1.0: 2010-11 Dodge 68RFE Automatic Transmission Please read all instructions before the installation of the ATS Co-Pilot Thank you for purchasing the ATS

More information

Water Valve Shutoff. WVS Water Valve Shutoff

Water Valve Shutoff. WVS Water Valve Shutoff Water Valve Shutoff Monitors flooding from leaking or broken water line Automatic control of main water supply line Form C Relay output for external monitoring devices Visual and audible status indicators

More information

CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS...

CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS... CONTENTS SUBJECT PAGE TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS... 8 SEC 4 - BATTERY CHARGING NOTES... 9 SEC 5 - VERIFICATION

More information

LED Downlight Ceiling Fixtures

LED Downlight Ceiling Fixtures ED Downlight Ceiling Fixtures Every attempt has been made to ensure that this documentation is as accurate and up-to-date as possible. However, Vertical Express assumes no liability for consequences, directly

More information

OTHER ELECTRICAL MEASURING DEVICES

OTHER ELECTRICAL MEASURING DEVICES Other measuring devices are used to aid operators in determining the electric plant conditions at a facility, such as the ampere-hour meter, power factor meter, ground detector, and synchroscope. EO 1.2

More information

26 SI HEAVY DUTY BRUSHLESS ALTERNATOR SERVICE MANUAL 1G-287 PRODUCT INFORMATION 1/98 26-SI ALTERNATOR 1G/287 4/96 PAGE

26 SI HEAVY DUTY BRUSHLESS ALTERNATOR SERVICE MANUAL 1G-287 PRODUCT INFORMATION 1/98 26-SI ALTERNATOR 1G/287 4/96 PAGE 26-SI ALTERNATOR G/287 4/96 PAGE G-287 PRODUCT INFORMATION /98 26 SI HEAVY DUTY BRUSHLESS ALTERNATOR SERVICE MANUAL 998 Delco Remy International Inc. All Rights Reserved. PAGE G-287 4/96 26-SI ALTERNATOR

More information

TECHNICAL NOTE #4 Revised May 24, BOGART ENGINEERING Two Bar Road, Boulder Creek, CA (831)

TECHNICAL NOTE #4 Revised May 24, BOGART ENGINEERING Two Bar Road, Boulder Creek, CA (831) TECHNICAL NOTE #4 Revised May 24, 2004 BOGART ENGINEERING 19020 Two Bar Road, Boulder Creek, CA 95006 (831) 338-0616 TROUBLESHOOTING the TriMetric battery monitor Revised for the TM-2020 TriMetric What

More information

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3. 41-348.1H Type SA-1 2.1. RESTRAINT CIRCUIT The restraint circuit of each phase consists of a center-tapped transformer, a resistor, and a full wave rectifier bridge. The outputs of all the rectifiers are

More information

Aura Interior Wiring Manual (5-Wire and BACnet)

Aura Interior Wiring Manual (5-Wire and BACnet) (5-Wire and BACnet) Table Of Contents Preparation......2 Warranty.....2 Aura Interior Product Overview....3 Aura Interior Power Wiring......4 Aura Interior RS485 Wiring...5 Aura Interior Remote Motion

More information

Servo and Proportional Valves

Servo and Proportional Valves Servo and Proportional Valves Servo and proportional valves are used to precisely control the position or speed of an actuator. The valves are different internally but perform the same function. A servo

More information

Science Olympiad Shock Value ~ Basic Circuits and Schematics

Science Olympiad Shock Value ~ Basic Circuits and Schematics Science Olympiad Shock Value ~ Basic Circuits and Schematics Use a single D battery, a single bare wire and a light bulb. Find four different ways to light the light bulb using only a battery, one wire

More information

DC400 Dispensing Cutoff System

DC400 Dispensing Cutoff System DC400 Dispensing Cutoff System Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com Important

More information

Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5. Installation Manual

Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5. Installation Manual Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5 Installation Manual ALCATEL-LUCENT DC METRO CELL AWS (B4) KIT INSTALLATION INSTRUCTIONS Document Information Identification

More information

WARNING. Models Magnetic Sensor Tachometer 3000 RPM; pulses 12 VDC

WARNING. Models Magnetic Sensor Tachometer 3000 RPM; pulses 12 VDC Tachometer and Tach/Hourmeter Installation Instructions Series: ATS, ATHS, ATA, ATHA, ATHI Please read the following instructions before installing. A visual inspection is recommended before mounting.

More information

User Guide. BreezePro TPW-400DT 12/24V 400W Wind Turbine A. NOTICE. B. SAFETY PRECAUTIONS (Important) C. About BreezePro

User Guide. BreezePro TPW-400DT 12/24V 400W Wind Turbine A. NOTICE. B. SAFETY PRECAUTIONS (Important) C. About BreezePro A. NOTICE User Guide BreezePro TPW-400DT 12/24V 400W Wind Turbine 1. This information is believed to be reliable; however, We assume no responsibility for inaccuracies or omissions. The user of this information

More information

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL Blank page Contents Caution... 4 Capabilities... 4 Display and Keypad... 4 Preparations Before the Test... 6 Connecting

More information

MDX-645P INSTRUCTION MANUAL. Battery Conductance Analyzer. For 6 & 12-volt automotive starting batteries

MDX-645P INSTRUCTION MANUAL. Battery Conductance Analyzer. For 6 & 12-volt automotive starting batteries MDX-645P Battery Conductance Analyzer For 6 & 12-volt automotive starting batteries INSTRUCTION MANUAL Blank page Contents Safety Guidelines 5 Capabilities 5 Registering Your MDX-Series Tester 7 Display

More information