Boiler room components 0459EN October 2013 Safety pressure switch with manual reset

Size: px
Start display at page:

Download "Boiler room components 0459EN October 2013 Safety pressure switch with manual reset"

Transcription

1 0459EN October 03 Safety pressure switch with manual reset Installation The lockout pressure switch must be installed by qualified personnel. The pressure switch K374Y00 can be assembled either vertically or horizontally by screwing it onto a pipe or a /4 Gc male threaded coupling after preparing the latter with a plug + paste mastic, teflon tape, or anaerobic seal; when properly applied, these materials ensure the seal on the coupling between the /4 Gj female connection of the pressure switch and the /4 Gc male part. K374Y00 Description Safety pressure switch with manual reset, for stopping the heat flow from the heat generator when the predefined maximum system pressure threshold (lockout pressure) is reached. The device is and complies with PED directive 97/3/EC. Allowed installation Setting The lockout pressure value is factory-set at 3 bar. This value can be modified with the aid of a tool, intervening on the regulation nut on the upper part of the casing; read the value on the graduated scale on the side. Triggering The device is triggered when the pressure level reaches the set lockout value; the opening of the contacts causes the heat generator to stop. Reset The system can only be reactivated by pressing the reset button on the lower part of the casing. This must be done when the pressure falls 0,4 bar lower than the set value. Main characteristics /4 F connection Two normally closed contacts (wire section 0,5 4 mm²) Reset button (differential 0,4 bar, tolerance ±0, bar) Graduated scale, visible from the outside Nominal current 6 A (resistive load) A (inductive load) Nominal voltage 50 V Operating temperature range C Protection degree IP44 Not allowed installation The connection pipe between the pressure switch and the system must have a minimum internal diameter of 8 mm if the pipe is less than one metre long, 5 mm if the pipe is more than one metre long, and 0 mm if it feeds other devices apart from the pressure switch (regardless of its length). The pressure switch must be fixed in place using an open-end spanner no.9 (recommended tightening moment: 35 Nm). If the theoretical short-circuit current is greater than the maximum nominal capacity of the electric contacts, it is compulsory to use a current protection device upstream from the pressure switch, with an intervention value equal to - or less than - 8 A. Electric connection The pressure switch K374Y00 has two NC electric contacts isolated from each other. When the system is subjected to a normal pressure level, the contacts remain closed. When the maximum set lockout pressure value is reached, both contacts are opened. Technical data Fluid temperature range 4 0 C Max. working pressure 5 bar Factory calibration 3 bar Regulation range 5 bar Certifications Compliance with PED directive 97/3/EC and ISPESL PS/00/0C EC mark

2 0459EN October 03 Safety pressure switch with manual reset Regulation To regulate (if necessary) the lockout pressure value, intervene on the regulation nut; read the value on the graduated scale. REGOLATION NUT Normative references R collection INAIL (I.S.P.E.S.L.) R collection for boiler room safety, protection and checks: italian D.M PED European Pressure Equipment Directive (97/3/EC). /LOAD CONNECTION CONNECTION RESET BUTTON GRADUATED SCALE Product specifications K374Y00 Safety pressure switch with manual reset. Lockout pressure factory calibration 3 bar. Regulation range 5 bar. /4 F connection. Button for manual reset (differential 0,4 bar; tolerance ±0, bar). Two normally closed contacts (wire section 0,5 4 mm²). Graduated scale, visible from the outside. Nominal current 6 A (resistive load); 0 A (inductive load). Nominal voltage 50 V. Protection degree IP44. Dimensions 04x00x60 mm (LxHxW). Operating temperature range C. Fluid temperature range 4 0 C. Max. working pressure 5 bar. Compliance with PED directive 97/3/EC.. Use Avoid the following situations at all costs: Exceeding the envisaged outdoor temperature (55 C) Exceeding the envisaged liquid temperature (0 C) Using with unclean water Using in environments with a highly corrosive atmosphere Initial start-up Before using the pressure switch, make sure that: the appropriate current protection devices are installed, if necessary the electrical connection has been made correctly there are no water leaks from the hydraulic connection (pressure switch - system) Maintenance and Checks Every year: visual check for any fluid leakages and/or corrosion Every 3 years: check the opening of the contacts Any repair and/or modification on the K374Y00 must be authorised by Giacomini S.p.A. in writing. Failure to observe any single one of the above indications will relieve Giacomini S.p.A of all civil and criminal responsibility. Dimensions H L W L [mm] H [mm] W [mm] Additional information For further information, visit the website or contact the technical service: ' * consulenza.prodotti@giacomini.com This information is intended as an example. Giacomini S.p.A. reserves the right to modify the contents - at any time and without prior warning - for technical or commercial reasons. The information in this technical sheet does not exempt the user from scrupulously observing the existing regulations and standards relating to good technical practices. Giacomini S.p.A. Via per Alzo, San Maurizio d Opaglio (NO) Italy

3 0460EN October 03 Manual reset pressure switch Installation The lockout pressure switch must be installed by qualified personnel. The pressure switch can be mounted either in vertical or in horizontal position, and with the cable glands turned to the floor, by screwing it to on a pipe or threaded fitting ¼ Gc male, that shall have been opportunely prepared with tow + putty in paste or Teflon tape, or anaerobic sealant (such materials, opportunely applied ensure the tightness of the coupling of the ¼ Gj female connection of the pressure switch with the male part ¼ Gc. K374Y00 Description The minimum pressure switch allows the control of the minimum pressure of a hot water system, according to 97/3/CE (PED) Directive and the provisions of the Italian (I.S.P.E.S.L.) Raccolta R Allowed installation Operation The pressure switch has two electrical contacts, normally open. With pressurized system, the contacts both close. Both contacts will be opened when the set minimum pressure of block will be reached. Restoration In order to reactivate the system, press the reset pushbutton, positioned on the higher part of the pressure switch when the pressure is risen 0.5 bar over the block value. Main characteristics /4 F connection Differential for reset 0,5 bar Tolerance ±0, bar Nominal current 6 A (resistive load) A (inductive load) Nominal voltage 50 V Operating temperature range C Protection degree IP44 Technical Data Fluid temperature range 4 0 C Max. working pressure 5 bar Factory calibration 0,9 bar Regulation range 0,5,7 bar Not allowed installation The connection pipe between the pressure switch and the system shall have minimum internal diameter of 8 mm, if the pipe is less than a meter long, 5 mm if the pipe length is higher than a meter, and 0 mm if it supplies other devices in addition to the pressure switch, regardless of its length. The fastening of the pressure switch shall be made with a fixed key no.9 (recommended torque setting: 35 Nm). Where the theoretic short circuit voltage is higher than the maximum nominal capacity of the electrical contacts, upstream of the pressure switch the use of a protection with intervention values lower than or equal to 8A is compulsory. Electrical connection The pressure switch K374Y00 has two electrical contacts, insulated one from the other, normally open. When the system is pressurized, both contacts close. When the minimum set block pressure is reached, both contacts are opened. Certifications Compliance with PED directive 97/3/EC and ISPESL PS/00/0C EC mark

4 0460EN October 03 Manual reset pressure switch Regulation In order to regulate the block pressure value, if needed, act on the regulation nut; this value is readable on the graduated scale. The following situations must be absolutely avoided: overcoming of the expected external temperature (55 C) overcoming of the expected temperature of the liquid (0 C) use with not clean water use in rooms with strongly corrosive atmosphere Normative references R collection INAIL (I.S.P.E.S.L.) R collection for boiler room safety, protection and checks: italian D.M PED European Pressure Equipment Directive (97/3/EC). REGULATION NUT RESET PUSHBUTTON / LOAD GRADUATED SCALE Initial start-up Before starting the pressure switch, make sure that: the opportune voltage protections are present, where requested the electrical connection is complying there are no leakage from the hydraulic connection (pressure switch-system). Maintenance and checks Every year: visual check for any fluid leakages and/or corrosion Every 3 years: check the opening of the contacts Any repair and/or modification on the K374Y00 must be authorised by Giacomini S.p.A. in writing. Failure to observe any single one of the above indications will relieve Giacomini S.p.A of all civil and criminal responsibility. Dimensions H L W L [mm] H [mm] W [mm] Additional information For further information, visit the website or contact the technical service: ' * consulenza.prodotti@giacomini.com This information is intended as an example. Giacomini S.p.A. reserves the right to modify the contents - at any time and without prior warning - for technical or commercial reasons. The information in this technical sheet does not exempt the user from scrupulously observing the existing regulations and standards relating to good technical practices. Giacomini S.p.A. Via per Alzo, San Maurizio d Opaglio (NO) Italy

5 046EN October 03 Pressure switches for autoclaves Regulation To make the regulation, observe the figure below and the minimum - maximum setting diagrams on the next page. A) Fully loosen the differential nut () B) Adjust the minimum gap nut () to establish the contact closure value (pump start); turn clockwise to increase the start pressure, or anticlockwise to reduce it C) Tighten the differential nut () until you obtain the required stoppage pressure K374Y003 K374Y004 Description Pressure switch for use with cold water in autoclave systems (e.g. fire-fighting systems). The switch automatically regulates the starting and stopping of the circulator, on the basis of the pressure values set. The electric contacts are of the normally closed type. The device complies with PED directive 97/3/EC. Main characteristics /4 F connection Three NC electric contacts (in brass alloy with Ag - Ni weld beading) Nominal current 6 A (resistive load); 0 A (inductive load) Nominal voltage 500 V Ambient temperature range C Protection degree IP44 Technical data Fluid temperature range 4 55 C Max. working pressure K374Y003: 5 bar K374Y004: bar Factory calibration K374Y003:,4,8 bar K374Y004: 5 7 bar Electric connections Regulation range K374Y003: 5 bar K374Y004: 3 bar Certifications Compliance with PED directive 97/3/EC EC mark

6 046EN October 03 Pressure switches for autoclaves Regulation range K374Y003 K374Y Maximum setting (bar) Maximum setting (bar) Minimum setting (bar) Minimum setting (bar) Dimensions H L L [mm] H [mm] W [mm] Normative references R collection INAIL (I.S.P.E.S.L.) R collection for boiler room safety, protection and checks: italian D.M W Product specifications K374Y003 Pressure switch for use with cold water in autoclave systems. Factory calibration,4,8 bar. Regulation range 5 bar. /4 F connection. Three NC contacts (in brass alloy with Ag - Ni weld beading). Nominal current 6 A (resistive load); 0 A (inductive load). Nominal voltage 500 V. Protection degree IP44. Dimensions 04x00x60 mm (LxHxW). Operating temperature range C. Fluid temperature range 4 55 C. Max. working pressure 5 bar. Compliance with PED directive 97/3/EC. K374Y004 Pressure switch for use with cold water in autoclave systems. Factory calibration 5 7 bar. Regulation range 3 bar. /4 F connection. Three NC contacts (in brass alloy with Ag - Ni weld beading). Nominal current 6 A (resistive load); 0 A (inductive load). Nominal voltage 500 V. Protection degree IP44. Dimensions 04x00x60 mm (LxHxW). Operating temperature range C. Fluid temperature range 4 55 C. Max. working pressure bar. Compliance with PED directive 97/3/EC. PED European Pressure Equipment Directive (97/3/EC). Additional information For further information, visit the website or contact the technical service: ' * consulenza.prodotti@giacomini.com This information is intended as an example. Giacomini S.p.A. reserves the right to modify the contents - at any time and without prior warning - for technical or commercial reasons. The information in this technical sheet does not exempt the user from scrupulously observing the existing regulations and standards relating to good technical practices. Giacomini S.p.A. Via per Alzo, San Maurizio d Opaglio (NO) Italy

Boiler room components 0459EN February 2018 Manual reset safety pressure switch

Boiler room components 0459EN February 2018 Manual reset safety pressure switch 0459EN February 08 Manual reset safety pressure switch K374Y00 Device intervention The device is activated when the preset locking pressure is reached; the heat generator stops when the electric contacts

More information

Metering systems 0483EN October 2013 Metering units for sanitary or service water

Metering systems 0483EN October 2013 Metering units for sanitary or service water 08EN October 0 Losses of Pressure The diagram showing losses of pressure is displayed below. For lower flow rate values, dashed lines are valid, due to the effect of the check valve spring.,00 Kv =, Δp

More information

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series Version A Version B GE552-1 Description The GE552-2 meters are thermal energy meters with double register and ultrasound,. They enable the measurement of energy used for heating and air-conditioning. They

More information

Actuator for mixing valves 0262EN March 2016

Actuator for mixing valves 0262EN March 2016 06EN March 06 07U758 -point floating actuator (connection M8 x,5 mm) for R98 and R98N mixing valves - K8 series 900 00 00A/ 800 006L/ Main features M8x,5 mm brass ring fixing to valve body. Immersion probe

More information

PUSH FITTINGS INSTA INST LLAT ALLA ION TION AND AND COMPONENTS COMPONENTS

PUSH FITTINGS INSTA INST LLAT ALLA ION TION AND AND COMPONENTS COMPONENTS PUSH FITTINGS INSTALLATION AND COMPONENTS SUMMARY 1. USE 1. TECHNICAL DATA 2. INSTALLATION WITH SYNTHETIC PIPES 3. INSTALLATION WITH COPPER PIPES 5. COMPONENTS 9. GUARANTEE June 2010 0135EN ISO 9001 0006/6

More information

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install.

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install. New Snap Disk Fixed setting pressure switches Compatible Refrigerants R22, R134a, R401, R402, R404, R407C, R410 and their lubricating oils, CO2 and R290 Our new range of electromechanical pressure switches

More information

Manifolds and preassembled groups 0687EN November 2017 Modular manifolds for domestic water systems with outputs connection 1/2 or 3/4 Eurocone

Manifolds and preassembled groups 0687EN November 2017 Modular manifolds for domestic water systems with outputs connection 1/2 or 3/4 Eurocone 0687N November 017 Modular manifolds for domestic water systems with outputs connection 1/ or /4 urocone R580 - R585 R580 R585 escription iacomini has introduced the R585 (with shut-off valve) and R580

More information

Metering systems 0368EN April /4 domestic water unit outputs

Metering systems 0368EN April /4 domestic water unit outputs 068EN pril 08 / domestic water unit outputs 07U98 Main characteristics Horizontal or vertical installation hut-off valves welded to water meter Dial with mechanical totalizers and index for partial consumptions

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION 770 EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual Technical Manual EH 1.2 General Information about valve sizing: Valves with a Full Port have an internal seat diameter that is the same as the nominal pipe

More information

Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012)

Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012) Valves Rapid opening and closing solenoid valves VMR (E1110 rev. 03-19/11/2012) GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff, respecting

More information

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE VMH Safety shut off valves for gas with hydraulic actuator DN65 DN200 www. delta-elektrogas.com EE168-0513 VMH Contents Description.. 3 Features.. 3 Functioning and application. 4 Special versions and

More information

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES E5 D811007 15-09-99 Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES 122 This product complies with recognised technical standards and safety regulations. We declare that this product is in conformity

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the 770

More information

XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL

XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL -Thermoplastic level gauges made of transparent polyamide with good mechanical resistance, are compatible with mineral oil, gasoline,

More information

Rotary Limit Switches Driver FRS Series

Rotary Limit Switches Driver FRS Series Rotary Limit Switches Driver FRS Series TM Limit Switches Driver FRS Series Main Features Driver rotary limit switch Series FRS is a device which allows you to control the movement of industrial and building

More information

PISTON ACCUMULATOR. Installation and operation manual Revision

PISTON ACCUMULATOR. Installation and operation manual Revision PISTON ACCUMULATOR Installation and operation manual Revision 2014-4 Content 1.0 INTRODUCTION 4 2.0 GENERAL SAFETY INSTRUCTIONS 5 3.0 WARRANTY 6 3.1 Limitation of the liability 6 4.0 TECHNICAL SPECIFICATIONS,

More information

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE VML Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 elektrogas.com EE162-1208 VML Safety solenoid valves for gas Slow opening and fast closing type Contents Description.. 2

More information

KAN-therm System. Series 71A, 75A, 51A, 55A manifolds. installation and maintenance instructions

KAN-therm System. Series 71A, 75A, 51A, 55A manifolds. installation and maintenance instructions instrukcja_rozdzielacz71a-55a_pl_ru_en:print 2010-09-30 14:14 Strona 25 KAN-therm System Series 71A, 75A, 51A, 55A manifolds installation and maintenance instructions Series 71A and 75A manifolds Installation

More information

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve Type 3310/AT and Type 3310/3278 Pneumatic Control Valves Type 3310 Segmented Ball Valve Fig. 1 Type 3310/3278 with positioner Fig. 2 Type 3310/AT Mounting and Operating Instructions EB 8222 EN Edition

More information

PCS. Proof of closure switch for safety gas valves. delta-elektrogas.com EE

PCS. Proof of closure switch for safety gas valves. delta-elektrogas.com EE PCS Proof of closure switch for safety gas valves delta-elektrogas.com EE170 0613 PCS Proof of closure switch for safety gas valves Contents Description...3 Features...3 Functioning and application...4

More information

VMH. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN EE

VMH. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN EE VMH Safety shut off valves for gas with hydraulic actuator DN65 DN300 delta-elektrogas.com EE175-0117 VMH Contents Description.. 3 Features.. 3 Functioning and application. 4 Special versions and optionals

More information

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve Electric Control Valves Types 3226/5857, 3226/5824, 3226/5825, 3226/5757-7, 3226/5724-8, 3226/5725-7, 3226/5725-8 Pneumatic Control Valve Type 3226/2780 Type 3226/5857 Type 3226/5757-7 Type 3226/2780-2,

More information

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE FEATURES The bronze ZEUS valve is intended for the automatic shutoff of networks of fluids. The full-bore inclined-seat body and the excellent flow-rate coefficients allow for very low pressure drops.

More information

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions Solar Thermal Grant Solar Pump Station Installation & Servicing Instructions Part No. DOC 96. Rev 02. October 2012 Important Note Important Note for Installers The Pump Station supplied with your Grant

More information

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions 4034450/9 IM-P403-15 AB Issue 9 BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions 1. Safety information 2. Application 3. Technical data 4. Operation 5. Installation 6. Rotating

More information

Rotary Limit Switches Driver FRM Series

Rotary Limit Switches Driver FRM Series Rotary Limit Switches Driver FRM Series TM Limit Switches Driver FRM Series Main Features The rotary limit switch is a device which allows you to control the movement of industrial and building machines.

More information

lubrication systems PEGPEO 5N-10N-25N-210N pumps for progressive systems

lubrication systems PEGPEO 5N-10N-25N-210N pumps for progressive systems lubrication systems PEGPEO 5N-10N-25N-210N pumps for progressive systems TABLE OF CONTENTS TABLE OF CONTENTS 2 Applications and operation 3 Technical data Operation 4 Tank 4 PEG-PEO 5N/10N/SM Electric

More information

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE FEATURES The stainless steel ARES valve is intended for the automatic shut-off of networks of fluids. The full-bore, inclined-seat body and the excellent flow-rate coefficients allow for very low pressure

More information

PBV s Engineering Excellence At Work

PBV s Engineering Excellence At Work PBV s Engineering Excellence At Work The PBV Series 5700/6700 Three-Piece, Side-Entry, Trunnion Ball Valve 2"- 56" ANSI Class 150/300,600,900,1500 & 2500 In Full And Standard Port PBV trunnion ball valves

More information

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Version with handwheel Mounting and Operating Instructions EB 8039 EN Edition May 2016 Definition of signal

More information

VALIADIS S.A. HELLENIC MOTORS

VALIADIS S.A. HELLENIC MOTORS Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe

More information

THROTTLE VALVES FOR RELAYS AND RADIATORS Series 2009

THROTTLE VALVES FOR RELAYS AND RADIATORS Series 2009 THROTTLE VALVES FOR RELAYS AND RADIATORS Series 2009 1General Features 1.1Characteristics The butterfly valves, metal to metal sealing withy thin blade(or full tightening type, with o-ring blade), are

More information

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump Electric control valves with jet pump Type 3267/5824, Type 3267/5825, Type 3267/3374, Type 3267/3274 Pneumatic control valves with jet pump Type 3267-1, Type 3267-7 Flanged version of valve with jet pump

More information

M4 Troubleshooting 42

M4 Troubleshooting 42 43 81 119 157 M4 Troubleshooting 42 Certificate of compliance DECLARATION OF CONFORMITY The undersigned, representing the following manufacturer Piusi S.p.A. 46029 Suzzara (Mantova) - Italy CERTIFIES

More information

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are

More information

ZB0050 / ZB0051 ZB0070 / ZB0071

ZB0050 / ZB0051 ZB0070 / ZB0071 Operating instructions Safety Rope Emergency Stop Switches UK ZB0050 / ZB0051 ZB0070 / ZB0071 7390877 / 02 08/2013 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4 2.2

More information

3. Operating instructions: Minor 200

3. Operating instructions: Minor 200 1. Technical specifications 3. Operating instructions: Minor 200 Copyright 2015 by Endecotts Ltd. 13 1. Setting up Technical specifications SIEVE SHAKER MODEL: Minor 200 General Information The Minor 200

More information

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax V2 S.p.A. Corso Principi di Piemonte, 65/67 12035 RACCONIGI (CN) ITALY tel. +39 01 72 81 24 11 - fax +39 01 72 84 050 info@v2home.com - www.v2home.com IL n.131 EDIZ. 28/08/2012 Bingo I GB F E P D NL ATTUATORE

More information

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX ATEX Type Certification marking for type L1X-EX, T1X-EX, T2X-EX Type of protection "d" explosion-proof enclosure Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

More information

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS TABLE OF CONTENTS 1.0 - WARNINGS 2.0 - GENERAL DATA 2.1 - Technical characteristics 2.2 - Data on electrical

More information

Pressostats and thermostats CAS

Pressostats and thermostats CAS MAKING MODERN LIVING POSSIBLE Technical brochure Pressostats and thermostats CAS www.danfoss.com Description CAS units are pressure-controlled switches. The position of the contacts depends on the pressure

More information

Flow Meter Terminal Boxes

Flow Meter Terminal Boxes Shutter Flow Meter Terminal Boxes Shutter Flow meter Terminal boxes 02 07 11 1 Shutter Valve DAROC Description and general specifications Production range and operating conditions Operation Installation,

More information

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes User Guide IM/TORBAR-EN Rev. D Torbar The Company We are an established world force in the design and manufacture of measurement products for industrial process control, flow measurement, gas and liquid

More information

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Resistance thermometer Model TR10-L, Ex d, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-L, Ex d, for additional thermowell WIKA data sheet TE 60.12 for further approvals see page 6 Applications Chemical industry Petrochemical

More information

VUD: 2-way flanged valve, PN 6 (pn.)

VUD: 2-way flanged valve, PN 6 (pn.) Product data sheet 76.110 VUD: 2-way flanged valve, PN 6 (pn.) How energy efficiency is improved Efficient use in continuous control systems Features Continuous control of cold and hot water in closed

More information

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-8-002-US October 2016 Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions These instructions should be read by the Company

More information

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request) HYDRAULIC FILTRATION F4-DMD series In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1..1): F4-DMD/8/11: 7 bar (11 psi) F4-DMD1/3/4: 4 bar (8 psi) Housing Burst

More information

Bolier room components 0870EN October 2017 Boiler room manifold with hydraulic separator

Bolier room components 0870EN October 2017 Boiler room manifold with hydraulic separator olier room components 0870E October 2017 oiler room manifold Description The boiler room manifold is a steel multi-function device including derivations for the primary and secondary circuits, automatic

More information

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T 3.10.5.1) Burst 330 bar (4800 psi) (acc. to NFPA T 3.10.5.1) Housing

More information

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:

More information

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Guide

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Guide I854000.F M16005 Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Introduction This manual presents guidelines for the Installation, Operation and Maintenance of manual and automated Apollo

More information

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request) HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1.5.1): F1-XD4/63/1: 1 bar (15 psi) F1-XD16/25/4: 8 bar (12 psi) Housing Burst (acc. to

More information

Pressure chlorine changeover unit C 7520

Pressure chlorine changeover unit C 7520 BW 2 24 04 / 1 Content 1. Scope of delivery 2. Device description 3. Installation 4. Operation 5. Shutdown 6. Maintenance 7. Troubleshooting 1 Scope of delivery The chlorine gas changeover unit C 7520

More information

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk Black Teknigas Powerseat Eco Gas Safety Shut-Off Valve Technical, and Maintenance Details WattsIndustries.co.uk Safety shut off valves for gas, air and oil EN161 approved; EC certificated Robust construction

More information

Duplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300

Duplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300 Duplex Filter Pi 241 Nominal pressure 40 bar (580 psi), nominal size up to 300 1. Features High performance filters for modern hydraulic, lubrication and fuel systems Modular system Compact design Minimal

More information

Dragone Pump DROPSA SpA In conformity with section 1.7.4, app. I, EEC Dir. 98/37/CE

Dragone Pump DROPSA SpA In conformity with section 1.7.4, app. I, EEC Dir. 98/37/CE INSTRUCTIONS FOR USE Dragone Pump DROPSA SpA In conformity with section 1.7.4, app. I, EEC Dir. 98/37/CE Company Name DROPSA SpA Address via Croce 1, 20090 Vimodrone (Mi), Italy Model DRAGONE pump Year

More information

Type overview. R B2 en-gb subject to changes 1

Type overview.  R B2 en-gb subject to changes 1 Technical data sheet R30..-..-..-B2 Characterised control valve, 6-way, Internal thread Two sequences (cooling/heating) with one 90 rotary actuator Switching or modulating control on the water side of

More information

Liquid filled Thermometers

Liquid filled Thermometers Liquid filled Thermometers Description and general specifications Liquid filled contact thermometers Operating instructions and maintenance Finished product quality control tests 02 02 05 06 1 Description

More information

Valves For Cryogenic Applications

Valves For Cryogenic Applications Valves For Cryogenic Applications Red Dragon has been supplying specialist valve products to all industries for over 20 years and we are proud of our reputation for service, quality and speed of delivery.

More information

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) HYDRAULIC FILTRATION Medium pressure, in line spin-on filters Technical Information Pressure: Max working (acc. to NFPA T 3.10.17): FA-4-1x: 34,5 bar (500 psi) FA-4-21: 24 bar (348 psi) Burst (acc. to

More information

VPI45..Q with pressure test points. Combi valves, PN 25

VPI45..Q with pressure test points. Combi valves, PN 25 4 853 VPI45.. VPI45..Q with pressure test points ACVATIX Combi valves, PN 25 for rooms, zones, air handling units as well as small to medium heating, ventilation and air-conditioning systems VPI45.. VPI45..Q

More information

GTFLOW EXTENSION MANIFOLD ASSEMBLY INSTRUCTIONS

GTFLOW EXTENSION MANIFOLD ASSEMBLY INSTRUCTIONS Page 1 of 5 Step 1: ASSEMBLE THE MAIN MANIFOLD AND MANIFOLD EXTENSION KIT First and very important step is to properly connect the main manifold and the manifold extension kit together by using the two

More information

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas Volumeter TRZ 0-K PRODUCT INFORMATION Reliable Measurements of Gas Method of operation, Construction Method of operation The TRZ 0-K Volumeter is a flow meter suitable for metering gases, where the rate

More information

Instructions for installation, operation and maintenance of: GATE VALVE

Instructions for installation, operation and maintenance of: GATE VALVE Instructions for installation, operation and maintenance of: GATE VALVE GEN GAC GAF/GENF TERMOVENT SC Temerin Republic of Serbia Instruction for installation, operation and maintenance: Table of Contents

More information

Mounting and Operating Instructions EB 5868/5869 EN

Mounting and Operating Instructions EB 5868/5869 EN Electric Control Valves Types 3213/5857, 3213/5824, Types 3214/5824, 3214/3374, 3214/3274 with safety function: Types 3213/5825, 3214/5825, 3214/3374, 3214/3274 Pneumatic Control Valves Types 3213/2780-1,

More information

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2 Installation and Operating Instructions Differential-Pressure Flow -MS1 -MS2 2 Table of Contents 1. Foreword...3 2. Safety...3 2.1. Symbol and meaning...3 2.2. General safety directions and exemption from

More information

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181 Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:

More information

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves Installation, Operation, Maintenance Instructions Standard Valves Series 035 000 Globe Valves Series 031 000 Angle Valves Series 033 000 3-Way-Valves 1 GENERAL INFORMATION These instructions are designed

More information

Block mounting filter, for sandwich plate mounting

Block mounting filter, for sandwich plate mounting Block mounting filter, for sandwich plate mounting RE 51427/01.11 1/16 Type 320PZR025, 075, 125 Size according to DIN 24550: 025 to 125 Nominal pressure 320 bar [4641 psi] Port according to ISO4401 size

More information

Data sheet Pressure controls and thermostats type CAS August 2000 DKACT.PD.P10.B B0616

Data sheet Pressure controls and thermostats type CAS August 2000 DKACT.PD.P10.B B0616 Data sheet Pressure controls and thermostats type CAS August 2000 DKACT.PD.P10.B2.02 520B0616 Pressure controls, type CAS Range Further 0 10 20 30 40 50 60 bar p e Type information bar page Standard pressure

More information

502 VALVE WITH UM1.5 ELECTRIC ACTUATOR. Model/Ref:

502 VALVE WITH UM1.5 ELECTRIC ACTUATOR. Model/Ref: Model/Ref: 270090022000 www.lauridsenindustri.com CHARACTERISTICS The 502+UM1.5 is a 2-way brass ball valve dedicated to the automatic shut-off of non-corrosive common fluids: water, air, hydrocarbons,

More information

Compact pressure switch Model PCS

Compact pressure switch Model PCS Mechatronic pressure measurement Compact pressure switch Model PCS WIKA data sheet PV 33.30 for further approvals see page 4 Process Compact Series Applications Pressure monitoring and control of processes

More information

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user.

WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user. CP-UM-5706E Product by Germany s Elster GmbH High-Performance Gas Solenoid Valve for Industrial Applications GV-A User's Manual WARNING Before wiring, installing, or removing the unit, be sure to turn

More information

These installation and maintenance instructions must be read in full and completely understood before the installation!

These installation and maintenance instructions must be read in full and completely understood before the installation! These installation and maintenance instructions must be read in full and completely understood before the installation! 1. General information on the installation and maintenance instructions These instructions

More information

Rosemount 485 Annubar Threaded Flo-Tap Assembly

Rosemount 485 Annubar Threaded Flo-Tap Assembly Quick Installation Guide 00825-0500-809, Rev DB Threaded Flo-Tap 85 Annubar Rosemount 85 Annubar Threaded Flo-Tap Assembly Step 1: Location and Orientation Step 2: Weld Mounting Hardware Step 3: Install

More information

Economizer pressure Reducing valves

Economizer pressure Reducing valves Economizer pressure Reducing valves Cryogenic valves Gauge valves In 1954 Leopoldo Boscarol set up the Milanese company that still today bears his name, immediately making his mark in the sector for the

More information

DIAMOND POINT VIBRATING PROBES

DIAMOND POINT VIBRATING PROBES DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527

More information

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321 Valve Series V2001 Globe Valve Type 3321 Fig. 1 Type 3321 Valve with mounted rod-type yoke for pneumatic or electric actuators (partial view) Mounting and Operating Instructions EB 8111/8112 EN Edition

More information

Installation and Operating Instructions

Installation and Operating Instructions Original Installation and Operating Instructions Hawle E2 Valve with Flange Outlet, System 2000 or PE Spigot Ends Table of Contents A) General...... 2 A1 Symbols..... 2 A2 Intended use... 2 A3 Labeling...

More information

Line filter with filter element according to DIN 24550

Line filter with filter element according to DIN 24550 Line filter with filter element according to DIN 2455 RE 51423/9.12 Replaces: 7.1 1/2 Type 445LEN4 to 1 Size according to DIN 2455: 4 to 1 Nominal pressure: 45 bar [6527 psi] Connection up to G 1 1/2;

More information

VG7000 Series Bronze Control Valves

VG7000 Series Bronze Control Valves VG7000 Series Bronze Control Valves Installation Instructions VG7000 Part No. 14-1078-6, Rev. E Issued June 16, 2008 Supersedes August 12, 2002 Applications VG7000 Series Bronze Control Valves are primarily

More information

Valves. Slow opening and rapid closing solenoid valves VM-L (E1111 rev /11/2012)

Valves. Slow opening and rapid closing solenoid valves VM-L (E1111 rev /11/2012) Valves Slow opening and rapid closing solenoid valves VM-L (E1111 rev. 03-19/11/2012) GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff,

More information

franklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps

franklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps franklinwater.com 5 Hz VR SERIES Vertical Multi-Stage Pumps 5 HZ VR SERIES VERTICAL MULTI-STAGE PUMPS Features 2 Applications 2 Pump Specifications Counter-Flange Kits Motor Specifications 4 Ordering

More information

Pressure Control, Differential Pressure Control, Type RT

Pressure Control, Differential Pressure Control, Type RT MAKING MODERN LIVING POSSIBLE Data sheet Control, Control, Type RT An RT control contains a operated single-pole changeover contact, the position of which depends on the in the inlet connection and the

More information

Installation and Operating Instructions Electric Vibrators HV/VFL Series

Installation and Operating Instructions Electric Vibrators HV/VFL Series Installation and Operating Instructions Electric Vibrators HV/VFL Series Original Instruction Würges Vibrationstechnik GmbH Daimlerstraße 9 D-86356 Neusäß Telephone +49 821 463081 Telefax +49 821 463084

More information

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2. PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL Flashing Light Push Button Control box Gate 2 Gate 1 Declaration of Conformity Applicant: Powertech Electronics Inc. Manufacturer:

More information

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX 4 853 VPI45.. VPI45..Q with pressure test points ACVATIX Combi valves, PN 25 for rooms, zones, air handling units as well as small to medium heating, ventilation and air-conditioning systems VPI45.. VPI45..Q

More information

ST11 Structural Straightening

ST11 Structural Straightening Uniform Procedures For Collision Repair ST11 Structural Straightening 1. Description This procedure describes repair methods and inspection requirements for straightening structural parts using hydraulic

More information

1. GENERAL SAFETY INSTRUCTIONS 2. GENERAL SAFETY RULES GENERAL OBSERVATIONS.

1. GENERAL SAFETY INSTRUCTIONS 2. GENERAL SAFETY RULES GENERAL OBSERVATIONS. ENGLISH IMPORTANT: The manual you are reading contains fundamental information regarding the safety measures to be adopted when installing and starting up. It is therefore of utmost importance that both

More information

VPI45..Q with pressure test points. Combi valves, PN 25

VPI45..Q with pressure test points. Combi valves, PN 25 4 853 VPI45.. VPI45..Q with pressure test points ACVATIX Combi valves, PN 25 for rooms, zones, air handling units as well as small to medium heating, ventilation and airconditioning systems VPI45.. VPI45..Q

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

VTZ variable speed Reciprocating compressors

VTZ variable speed Reciprocating compressors MAKING MODERN LIVING POSSIBLE Application guidelines VTZ variable speed Reciprocating compressors R404A, R507, R407C, R134a www.danfoss.com CONTENT VARIABLE SPEED COMPRESSORS... 4 Speed control...4 Advantages

More information

Operating Instructions. Valves Atkomatic Series ATEX and Series ATEX Series Series

Operating Instructions. Valves Atkomatic Series ATEX and Series ATEX Series Series Operating Instructions Valves Atkomatic 15800 Series ATEX and 30800 Series ATEX 15800 Series 30800 Series Atkomatic 15800 Series ATEX and 30800 Series ATEX Installation and Maintenance Instructions Revision

More information

Pumps and pumping units SL i & Micro C

Pumps and pumping units SL i & Micro C INSTRUCTIONS 1071 e Section Effective October 2016 Replaces April 2016 Original instructions Additional instructions for ATEX certified equipment Pumps and pumping units SL i & Micro C Дистрибутор: България,

More information

RVP-R- VAV controller. In explosion-proof version

RVP-R- VAV controller. In explosion-proof version VAV controller In explosion-proof version RVP-R- SMAY LLC / 29 Ciep³ownicza St. / 31-587 Cracow / Poland tel. +48 12 378 18 00 / fax. +48 12 378 18 88 / e-mail: info@smay.eu Intended use VAV control units

More information

Access Interlock with Safety Switch User Manual - Original Language Version

Access Interlock with Safety Switch User Manual - Original Language Version -FSS-KF-2 The or HERCULES is a single key access interlock complete with electrical contacts for use on hinged and sliding doors. The Hercules contacts can be used to switch off the machine via its control

More information

Installation and Operation Manual. Value Switch Package (VSP and VSP+)

Installation and Operation Manual. Value Switch Package (VSP and VSP+) Installation and Operation Manual Value Switch Package (VSP and VSP+) Table of Contents Table of Contents Introduction and Safety... 2 Safety message levels... 2 User health and safety... 2 Transportation

More information