Boiler room components 0459EN February 2018 Manual reset safety pressure switch

Size: px
Start display at page:

Download "Boiler room components 0459EN February 2018 Manual reset safety pressure switch"

Transcription

1 0459EN February 08 Manual reset safety pressure switch K374Y00 Device intervention The device is activated when the preset locking pressure is reached; the heat generator stops when the electric contacts open. Reset The system can be restarted only by pushing the special reset button on the lower side of the case when the pressure drops by 0,5 bar below the setting value. Use Always avoid the following: Exceeding the expected room temperature (50 C) Exceeding the expected fluid temperature (0 C) Using unclean water Use in rooms with highly corrosive air Description Manual reset safety pressure switch to cut off the heat from the heat generator when reaching the system preset limit of maximum pressure (locking pressure). Device complying with directive PED 04/68/UE. Versions and product codes Product code Connection Control range K374Y00 /4 F 4,5 bar Technical data Fluid temperature range: 0 0 C Fluid class: Compatible fluids: water and glycol-based solutions (max. 50 %) Room temperature range: 0 50 C (RH 85 % max) Max. working pressure: 5 bar Control range: 4,5 bar Factory setting: 3 bar Reset min. differential: 0,5 bar Construction tolerance: ± 0,5 bar Nominal current: 6 A (resistive load) / 0 A (inductive load) Max. voltage: 50 V, 50/60 Hz Section of electric wires used: 0,75 4 mm² Protection class: IP44 Operation Setting The default locking pressure value is 3 bar. The value can be reset using a tool by turning the adjustment nut in the upper part of the case which includes a graduated scale on the side. CONENCTION /LOAD ADJUSTMENT NUT L N K374Y00 GRADUATED SCALE Installation The safaty pressure switch must be installed by qualified operators. The pressure switch is a device able to cut off the heat generator electric system. However, it cannot limit any pressure increase caused by heat inertia that may occur after the pressure switch is engaged. For such reason, devices preventing the pressure value from dropping below the maximum value admitted of 5 bar (es. safety valve) and the fluid temperature from dropping below 0 C (thermostat) must also be installed, in compliance with the safety standards. The pressure switch can be installed both horizontally and vertically screwing it on a /4 M (R, EN 06) threaded pipe or fitting after properly preparing the latter with oakum + putty, or PTFE, or anaerobic sealant (such materials guarantee sealing of the coupling when applied properly). The pipe connecting the pressure switch and the system must have a min. internal diameter of 8 mm if the pipe is shorter than a meter; 5 mm if the pipe is longer than a meter; 0 mm if it also serves other devices, whatever its length. The pressure switch must be installed with a n 7 wrench (recommended torque: 35 Nm). When the theoric short circuit current is greater than the max. nominal flow of the electric contacts, an electric current protection with intervention value lower or equal to 8 A must be installed before the pressure switch. Electric connections The K374Y00 pressure switch includes two electric contacts normally closed and insulated one from the other. Both contacts remain closed when the system is pressurized and both open when reaching the maximum locking pressure. LINE LINE L 50 V max. 6 (0) A N MANUAL RESET BUTTON

2 0459EN February 08 Manual reset safety pressure switch K374Y00 Start up Once installed, apply the anti-tampering seal on the adjustment screw to prevent modifications of the setting value by unauthorized people. Product specifications K374Y00 Manual reset safety pressure switch. /4 F connection. Locking pressure factory setting 3 bar. Control range: 4,5 bar. Manual reset button (differential 0,5 bar; tolerance ± 0,5 bar). Two contacts normally closed (wire section 0,75 4 mm²). Graduated scale visible from the outside. Nominal current 6 A (resistive load); 0 A (inductive load). Nominal voltage 50 V. Protection class IP44. Dimensions 04x00x60 mm (LxHxD). Room temperature range: 0 50 C. Fluid temperature range: 0 0 C. Max. working pressure: 5 bar. Complying with directive PED 04/68/UE. Before starting the pressure switch make sure: - Proper current protections have been installed where required - Electric connection has been executed in compliance with the applicable regulations - There are no water leaks from the hydraulic connection (pressure switch-system) Maintenance and inspections Every year: visual inspection to identify fluid leaks and/or corrosion. Every three years: verify proper contact opening. After every pressure switch intervention, verify there are no leaks both inside and outside the pressure switch, also removing the case. Also perform periodical mandatory inspections in compliance with the rules in force in the Country of installation. Every modification and/or repair performed on K374Y00 must be authorized in writing by Giacomini S.p.A. Failure to comply with any of the instructions above shall hold Giacomini S.p.A harmless from any civil and criminal responsibility. Dimensions B A C A [mm] B [mm] C [mm] Certifications Complying with directive PED 04/68/UE CE mark Additional information For more information, go to or contact our technical assistance service: ' * consulenza.prodotti@giacomini.com This document provides only general indications. Giacomini S.p.A. may change at any time, without notice and for technical or commercial reasons, the items included herewith. The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force. Giacomini S.p.A. Via per Alzo, San Maurizio d Opaglio (NO) Italy

3 0460EN February 08 Manual reset minimum pressure switch K374Y00 Device intervention The device is activated when the preset locking pressure is reached; the heat generator stops when the electric contacts open. Reset The system can be restarted only by pushing the special reset button on the lower side of the case when the pressure drops by 0,5 bar above the setting value. Use Always avoid the following: Exceeding the expected room temperature (50 C) Exceeding the expected fluid temperature (0 C) Using unclean water Use in rooms with highly corrosive air Description Manual reset minimum pressure switch to cut off the heat from the heat generator when reaching the system preset limit of minimum pressure (locking pressure). Device complying with directive PED 04/68/UE. Versions and product codes Product code Connection Control range K374Y00 /4 F 0,5,7 bar Technical data Fluid temperature range: 0 0 C Fluid class: Compatible fluids: water and glycol-based solutions (max. 50 %) Room temperature range: 0 50 C (RH 85 % max) Max. working pressure: 5 bar Control range: 0,5,7 bar Factory setting: 0,9 bar Reset min. differential: 0,5 bar Construction tolerance: ± 0,0 bar Nominal current: 6 A (resistive load) / 0 A (inductive load) Max. voltage: 50 V, 50/60 Hz Section of electric wires used: 0,75 4 mm² Protection class: IP44 Operation Setting The default locking pressure value is 0,9 bar. The value can be reset using a tool by turning the adjustment nut in the upper part of the case which includes a graduated scale on the side. ADJUSTMENT NUT MANUAL RESET BUTTON K374Y00 Installation The minimum pressure switch must be installed by qualified operators. The pressure switch is a device able to cut off the heat generator electric system. However, it cannot limit any pressure increase caused by heat inertia that may occur after the pressure switch is engaged. For such reason, devices preventing the pressure value from dropping below the maximum value admitted of 5 bar (es. safety valve) and the fluid temperature from dropping below 0 C (thermostat) must also be installed, in compliance with the safety standards. The pressure switch can be installed both horizontally and vertically screwing it on a /4 M (R, EN 06) threaded pipe or fitting after properly preparing the latter with oakum + putty, or PTFE, or anaerobic sealant (such materials guarantee sealing of the coupling when applied properly). The pipe connecting the pressure switch and the system must have a min. internal diameter of 8 mm if the pipe is shorter than a meter; 5 mm if the pipe is longer than a meter; 0 mm if it also serves other devices, whatever its length. The pressure switch must be installed with a n 7 wrench (recommended torque: 35 Nm). When the theoric short circuit current is greater than the max. nominal flow of the electric contacts, an electric current protection with intervention value lower or equal to 8 A must be installed before the pressure switch. Electric connections The K374Y00 pressure switch includes two electric contacts normally opened and insulated one from the other. Both contacts remain closed when the system is pressurized and both opened when reaching the minimum locking pressure. LINE LINE GRADUATED SCALE

4 0460EN February 08 Manual reset minimum pressure switch K374Y00 Start up Once installed, apply the anti-tampering seal on the adjustment screw to prevent modifications of the setting value by unauthorized people. Product specifications K374Y00 Manual reset safety pressure switch. /4 F connection. Locking pressure factory setting 0,9 bar. Control range: 0,5,7 bar. Manual reset button (differential 0,5 bar; tolerance ± 0,0 bar). Two contacts normally closed (wire section 0,75 4 mm²). Graduated scale visible from the outside. Nominal current 6 A (resistive load); 0 A (inductive load). Nominal voltage 50 V. Protection class IP44. Dimensions 04x00x60 mm (LxHxD). Room temperature range: 0 50 C. Fluid temperature range: 0 0 C. Max. working pressure: 5 bar. Complying with directive PED 04/68/UE. Before starting the pressure switch make sure: - Proper current protections have been installed where required - Electric connection has been executed in compliance with the applicable regulations - There are no water leaks from the hydraulic connection (pressure switch-system) Maintenance and inspections Every year: visual inspection to identify fluid leaks and/or corrosion. Every three years: verify proper contact opening. After every pressure switch intervention, verify there are no leaks both inside and outside the pressure switch, also removing the case. Also perform periodical mandatory inspections in compliance with the rules in force in the Country of installation. Every modification and/or repair performed on K374Y00 must be authorized in writing by Giacomini S.p.A. Failure to comply with any of the instructions above shall hold Giacomini S.p.A harmless from any civil and criminal responsibility. Dimensions B A C A [mm] B [mm] C [mm] Certifications Complying with directive PED 04/68/UE CE mark Additional information For more information, go to or contact our technical assistance service: ' * consulenza.prodotti@giacomini.com This document provides only general indications. Giacomini S.p.A. may change at any time, without notice and for technical or commercial reasons, the items included herewith. The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force. Giacomini S.p.A. Via per Alzo, San Maurizio d Opaglio (NO) Italy

5 Components for boiler room 046EN March 07 Pressure switches for autoclaves K374Y003, K374Y004 Regulation range To make the regulation, observe the figure below and the minimummaximum setting diagrams. Fully loosen the differential nut (). Adjust the minimum gap nut () to establish the contact closure value (pump start); turn clockwise to increase the start pressure, or anticlockwise to reduce it. Tighten the differential nut () until you obtain the required stoppage pressure. K374Y003 K374Y004 Description Pressure switch for use with cold water in autoclave systems (e.g. fire protection systems). The switch automatically regulates the starting and stopping of the circulator, on the basis of the pressure values set. The electric contacts are of the normally closed type. Minimum-maximum setting diagrams 6 K374Y003 Versions and product codes Product code Connection Regulation range Set pressure (factory calibration) K374Y003 /4 5 bar,4,8 bar K374Y004 /4 3 bar 5 7 bar Technical data Fluid temperature range 4 55 C Ambient temperature range C Protection degree IP44 Nominal voltage 500 V /4 F connection Three NC electric contacts (in brass alloy with Ag - Ni weld beading) Nominal current 6 A (resistive load); 0 A (inductive load) Max. working pressure K374Y003: 5 bar K374Y004: bar Set pressure (factory calibration) K374Y003:,4,8 bar K374Y004: 5 7 bar Regulation range K374Y003: 5 bar K374Y004: 3 bar Minimum differential K374Y003: 0,6 bar K374Y004:,5 bar Maximum differential K374Y003:,5 bar K374Y004: 5 bar Maximum setting (bar) Maximum setting (bar) Minimum setting (bar) K374Y Minimum setting (bar)

6 Components for boiler room 046EN March 07 Pressure switches for autoclaves K374Y003, K374Y004 Electrical connections LINE LINE LINE Dimensions B A C A [mm] B [mm] C [mm] Certifications Low Voltage Directive (LVD) 04/35/EU ROHS 0/65/EU EC mark Product specifications K374Y003 Pressure switch for use with cold water in autoclave systems. Factory calibration,4,8 bar. Regulation range 5 bar. /4 F connection. Three NC contacts (in brass alloy with Ag - Ni weld beading). Nominal current 6 A (resistive load); 0 A (inductive load). Nominal voltage 500 V. Protection degree IP44. Dimensions 04x00x60 mm (LxHxW). Operating temperature range C. Fluid temperature range 4 55 C. Max. working pressure 5 bar. Compliance with Low Voltage Directive (LVD) 04/35/EU; ROHS 0/65/EU. EC mark. K374Y004 Pressure switch for use with cold water in autoclave systems. Factory calibration 5 7 bar. Regulation range 3 bar. /4 F connection. Three NC contacts (in brass alloy with Ag - Ni weld beading). Nominal current 6 A (resistive load); 0 A (inductive load). Nominal voltage 500 V. Protection degree IP44. Dimensions 04x00x60 mm (LxHxW). Operating temperature range C. Fluid temperature range 4 55 C. Max. working pressure bar. Compliance with Low Voltage Directive (LVD) 04/35/EU; ROHS 0/65/EU. EC mark. Additional information For additional information please check the website or contact the technical service: ' * consulenza.prodotti@giacomini.com This pamphlet is merely for information purposes. Giacomini S.p.A. retains the right to make modifications for technical or commercial reasons, without prior notice, to the items described in this pamphlet. The information described in this technical pamphlet does not exempt the user from following carefully the existing regulations and norms on good workmanship. Giacomini S.p.A. Via per Alzo, San Maurizio d Opaglio (NO) Italy

Boiler room components 0459EN October 2013 Safety pressure switch with manual reset

Boiler room components 0459EN October 2013 Safety pressure switch with manual reset 0459EN October 03 Safety pressure switch with manual reset Installation The lockout pressure switch must be installed by qualified personnel. The pressure switch K374Y00 can be assembled either vertically

More information

Actuator for mixing valves 0262EN March 2016

Actuator for mixing valves 0262EN March 2016 06EN March 06 07U758 -point floating actuator (connection M8 x,5 mm) for R98 and R98N mixing valves - K8 series 900 00 00A/ 800 006L/ Main features M8x,5 mm brass ring fixing to valve body. Immersion probe

More information

Metering systems 0483EN October 2013 Metering units for sanitary or service water

Metering systems 0483EN October 2013 Metering units for sanitary or service water 08EN October 0 Losses of Pressure The diagram showing losses of pressure is displayed below. For lower flow rate values, dashed lines are valid, due to the effect of the check valve spring.,00 Kv =, Δp

More information

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series Version A Version B GE552-1 Description The GE552-2 meters are thermal energy meters with double register and ultrasound,. They enable the measurement of energy used for heating and air-conditioning. They

More information

Metering systems 0368EN April /4 domestic water unit outputs

Metering systems 0368EN April /4 domestic water unit outputs 068EN pril 08 / domestic water unit outputs 07U98 Main characteristics Horizontal or vertical installation hut-off valves welded to water meter Dial with mechanical totalizers and index for partial consumptions

More information

Manifolds and preassembled groups 0687EN November 2017 Modular manifolds for domestic water systems with outputs connection 1/2 or 3/4 Eurocone

Manifolds and preassembled groups 0687EN November 2017 Modular manifolds for domestic water systems with outputs connection 1/2 or 3/4 Eurocone 0687N November 017 Modular manifolds for domestic water systems with outputs connection 1/ or /4 urocone R580 - R585 R580 R585 escription iacomini has introduced the R585 (with shut-off valve) and R580

More information

Bolier room components 0870EN October 2017 Boiler room manifold with hydraulic separator

Bolier room components 0870EN October 2017 Boiler room manifold with hydraulic separator olier room components 0870E October 2017 oiler room manifold Description The boiler room manifold is a steel multi-function device including derivations for the primary and secondary circuits, automatic

More information

PUSH FITTINGS INSTA INST LLAT ALLA ION TION AND AND COMPONENTS COMPONENTS

PUSH FITTINGS INSTA INST LLAT ALLA ION TION AND AND COMPONENTS COMPONENTS PUSH FITTINGS INSTALLATION AND COMPONENTS SUMMARY 1. USE 1. TECHNICAL DATA 2. INSTALLATION WITH SYNTHETIC PIPES 3. INSTALLATION WITH COPPER PIPES 5. COMPONENTS 9. GUARANTEE June 2010 0135EN ISO 9001 0006/6

More information

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install.

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install. New Snap Disk Fixed setting pressure switches Compatible Refrigerants R22, R134a, R401, R402, R404, R407C, R410 and their lubricating oils, CO2 and R290 Our new range of electromechanical pressure switches

More information

ON/OFF zone valves AMZ 112, AMZ 113

ON/OFF zone valves AMZ 112, AMZ 113 Data sheet ON/OFF zone valves AMZ 112, AMZ 113 Description Features: Indication of actual valve position; LED indication of turning direction; Manual valve turning mode enabled by a permanent clutch; No

More information

XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL

XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL -Thermoplastic level gauges made of transparent polyamide with good mechanical resistance, are compatible with mineral oil, gasoline,

More information

VMH. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN EE

VMH. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN EE VMH Safety shut off valves for gas with hydraulic actuator DN65 DN300 delta-elektrogas.com EE175-0117 VMH Contents Description.. 3 Features.. 3 Functioning and application. 4 Special versions and optionals

More information

2-position electric actuators with Ball valves VBZ ½...11/4

2-position electric actuators with Ball valves VBZ ½...11/4 4 831.2 & VBZ ½...11/4 2-position electric actuators with Ball valves VBZ ½ 11/4 90 angle - Unidirectional rotation VBZ ½ 11/4 Electric rotary actuators for two-port ball valves Operating voltage AC 230

More information

ON/OFF zone valves AMZ 112, AMZ 113

ON/OFF zone valves AMZ 112, AMZ 113 Data sheet ON/OFF zone valves AMZ 112, AMZ 113 Description The ON/OFF zone valves type AMZ 112 and AMZ 113 are typical used in connection with: Domestic and commercial central heating applications Domestic

More information

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB otorised ball zone valves with -contact control -.. BY - series 00 0/ GB replaces 0/ GB unction The motorised zone valves permit automatically shutting off the medium in air conditioning or hydraulic and

More information

Content. 04 The Company. 13 Key to symbols. 22 Double walled tanks heads. 14 Dished heads table. 06 The catalogue and guide for the consultation

Content. 04 The Company. 13 Key to symbols. 22 Double walled tanks heads. 14 Dished heads table. 06 The catalogue and guide for the consultation GENERAL CATALOGUE Content 04 The Company 06 The catalogue and guide for the consultation 08 Certifications 10 Technical notes 12 Materials 13 Key to symbols 14 Dished heads table 16 Dished head type D

More information

Solenoid Valve DF-SB-series

Solenoid Valve DF-SB-series 2/2-WAY SEMI-DIRECT OPERATED NORMALLY OPEN Solenoid Valve DF-SB-series The DF-DB is a semi-direct operated 2/2-way solenoid valve. The valve is normally open. The solenoid valves have an orifice of 16

More information

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181 Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:

More information

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE VML Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 elektrogas.com EE162-1208 VML Safety solenoid valves for gas Slow opening and fast closing type Contents Description.. 2

More information

Solenoid Valve ST-IA-series

Solenoid Valve ST-IA-series 2/2-WAY INDIRECT OPERATED NORMALLY CLOSED Solenoid Valve ST-IA-series The ST-IA is an indirect operated 2/2-way solenoid valve. The valve is normally closed. The solenoid valves have an orifice of 13 to

More information

Duplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300

Duplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300 Duplex Filter Pi 241 Nominal pressure 40 bar (580 psi), nominal size up to 300 1. Features High performance filters for modern hydraulic, lubrication and fuel systems Modular system Compact design Minimal

More information

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE VMH Safety shut off valves for gas with hydraulic actuator DN65 DN200 www. delta-elektrogas.com EE168-0513 VMH Contents Description.. 3 Features.. 3 Functioning and application. 4 Special versions and

More information

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request) HYDRAULIC FILTRATION F4-DMD series In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1..1): F4-DMD/8/11: 7 bar (11 psi) F4-DMD1/3/4: 4 bar (8 psi) Housing Burst

More information

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T 3.10.5.1) Burst 330 bar (4800 psi) (acc. to NFPA T 3.10.5.1) Housing

More information

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings ST2 Ball valves in conjunction with spring return and non-spring return VA-Actuators Developed for HVAC applications

More information

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:

More information

Solenoid Valve DF-SA-series

Solenoid Valve DF-SA-series 2/2-WAY SEMI-DIRECT OPERATED NORMALLY CLOSED Solenoid Valve DF-SA-series The DF-DA is a semi-direct operated 2/2-way solenoid valve. The valve is normally closed. These valves have an orifice of 16 to

More information

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request) HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1.5.1): F1-XD4/63/1: 1 bar (15 psi) F1-XD16/25/4: 8 bar (12 psi) Housing Burst (acc. to

More information

Liquid filled Thermometers

Liquid filled Thermometers Liquid filled Thermometers Description and general specifications Liquid filled contact thermometers Operating instructions and maintenance Finished product quality control tests 02 02 05 06 1 Description

More information

PCS. Proof of closure switch for safety gas valves. delta-elektrogas.com EE

PCS. Proof of closure switch for safety gas valves. delta-elektrogas.com EE PCS Proof of closure switch for safety gas valves delta-elektrogas.com EE170 0613 PCS Proof of closure switch for safety gas valves Contents Description...3 Features...3 Functioning and application...4

More information

M-100 Adjustable flow switch with right-angle flow

M-100 Adjustable flow switch with right-angle flow M-100 Adjustable flow switch with right-angle flow Operating Instructions and Quick Start Guide Table of Contents Introduction 03 Operation 03 Storage and Handling 03 Installation Instruction 03 Specification

More information

Solenoid valves VZWP, servo-controlled

Solenoid valves VZWP, servo-controlled Key features and overview Function The solenoid valve VZWP-L- is a servo-controlled 2/2-way valve with solenoid coil. The solenoid valve is closed when de-energised. When energised, the differential pressure

More information

8000 Series Liquid Flow Meters

8000 Series Liquid Flow Meters PRODUCT DATA SHEET 8000 Series Liquid Flow Meters Advanced microprocessorbased flow measurement technology in a compact, leak-tight package Flow ranges from 0.2 to 227 LPM / 0.05 to 60 GPM Accuracy of

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) HYDRAULIC FILTRATION Medium pressure, in line spin-on filters Technical Information Pressure: Max working (acc. to NFPA T 3.10.17): FA-4-1x: 34,5 bar (500 psi) FA-4-21: 24 bar (348 psi) Burst (acc. to

More information

3. Operating instructions: Minor 200

3. Operating instructions: Minor 200 1. Technical specifications 3. Operating instructions: Minor 200 Copyright 2015 by Endecotts Ltd. 13 1. Setting up Technical specifications SIEVE SHAKER MODEL: Minor 200 General Information The Minor 200

More information

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves - Motorized 6-port Ball Valves Description NovoCon The and NovoCon are 6-port motorized ball valves that performs a diverting function between two water circuits in 4-pipe changeover system. This diverting

More information

Solenoid Valve ST-SA-series

Solenoid Valve ST-SA-series 2/2-WAY SEMI-DIRECT OPERATED NORMALLY CLOSED Solenoid Valve ST-SA-series The ST-SA is a semi-direct operated 2/2-way solenoid valve. The valve is normally closed. The body material can be brass or stainless

More information

Delta HE 35-XX, 55-XX

Delta HE 35-XX, 55-XX Installation and Operating Instructions Delta HE 35-XX, 55-XX 10.2009 Table of contents Table of contents EC Conformity Declaration Technical Data Delta HE 35 Technical Data Delta HE 55 Mounting Instructions

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

Rotary Limit Switches Driver FRS Series

Rotary Limit Switches Driver FRS Series Rotary Limit Switches Driver FRS Series TM Limit Switches Driver FRS Series Main Features Driver rotary limit switch Series FRS is a device which allows you to control the movement of industrial and building

More information

Listings and Approvals. G5 QR Gasket culus QR G5 SR Gasket culus, FM SR G5

Listings and Approvals. G5 QR Gasket culus QR G5 SR Gasket culus, FM SR G5 Model Series Sprinklers Available with Solid, Perforated, or Gasket Standard Coverage, Concealed Pendent K2.8, 4.2, 5.6, & 8.0 (40, 60, 80, & 115 metric) Features Flat concealed cover plate available solid

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating instructions...2 2 Intended use...3 3

More information

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi) HYDRAULIC FILTRATION F8-D1 series In line medium pressure filters Technical Information Housing Pressure: Max working F8 D1x port size 1/ & 3/4 : 4 bar (6 psi) F8 D1x port size 1 : 3 bar (4 psi) F8 D14x:

More information

Pressure Independent Control Valve

Pressure Independent Control Valve Pressure Independent Control Valve Rev. 4.0-06/06/2011 Technical manual Introduction The Pressure Independent Control Valve PICV is a combined constant flow limiter and full stroke, full authority equal

More information

502 VALVE WITH UM1.5 ELECTRIC ACTUATOR. Model/Ref:

502 VALVE WITH UM1.5 ELECTRIC ACTUATOR. Model/Ref: Model/Ref: 270090022000 www.lauridsenindustri.com CHARACTERISTICS The 502+UM1.5 is a 2-way brass ball valve dedicated to the automatic shut-off of non-corrosive common fluids: water, air, hydrocarbons,

More information

ZB0050 / ZB0051 ZB0070 / ZB0071

ZB0050 / ZB0051 ZB0070 / ZB0071 Operating instructions Safety Rope Emergency Stop Switches UK ZB0050 / ZB0051 ZB0070 / ZB0071 7390877 / 02 08/2013 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4 2.2

More information

Electromotoric actuators

Electromotoric actuators s 4 520 ACVATIX TM Electromotoric actuators SQL321B.. SQL361B.. For VKF42.. butterfly valves SQL321B.. Operating voltage AC 220 V, 2-position (SPDT) control signal SQL361B.. Operating voltage AC 220 V,

More information

PNEUMATIC PUMP Series

PNEUMATIC PUMP Series PNEUMATIC PUMP Series 3103... User and Maintenance Manual Original text translation TABLE OF CONTENTS 1. INTRODUCTION 2. GENERAL DESCRIPTION 3. PRODUCT-MACHINE IDENTIFICATION 4. TECHNICAL CHARACTERISTICS

More information

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T ) HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T 3.10.5.1) Burst 840 bar (12200 psi) (acc. to NFPA T 3.10.5.1) Housing

More information

Duplex Filter Pi 4700

Duplex Filter Pi 4700 MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Duplex Filter Pi 4700 Nominal pressure up to 315/350 bar (4570/4980 psi), nominal size 40 up to 400

More information

Operating instruction Refrigerant Valves PS45

Operating instruction Refrigerant Valves PS45 CDV II 3G Operating instruction Refrigerant Valves PS45 for flammable and safety refrigerants CDV..MVL.. One valve type for expansion, hot-gas and suction throttle applications Approved according to directive

More information

Electromotoric Actuators

Electromotoric Actuators 4 506 Electromotoric Actuators for valves with 90 angle of rotation operating voltage AC 230 V 3-position control signal Nominal angle of rotation 90 Auxiliary switch and potentiometer for extra functions

More information

Duplex Filter Pi Features. Nominal pressure 25/63 bar (360/900 psi), nominal size up to 450

Duplex Filter Pi Features. Nominal pressure 25/63 bar (360/900 psi), nominal size up to 450 Duplex Filter Pi Nominal pressure 25/63 bar (360/900 psi), nominal size up to 450 1. Features.High performance filters for modern hydraulic systems Modular system Compact design Minimal pressure drop through

More information

Pressure switch, high adjustability of switch differential

Pressure switch, high adjustability of switch differential switch, high adjustability of switch differential For the process industry Model PSM-700, with robust aluminium case WIKA data sheet PV 35.05 Applications Pumps for process applications (e.g. water treatment,

More information

Premounted Midi Shunts

Premounted Midi Shunts Application Midi Shunt 088U0181 - with one circuit Midi Shunt 088U0182 - with two circuits Midi Shunt 088U0183 - with three circuits The Danfoss floor heating midi shunt is a series of pre-mounted shunts

More information

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6 4 241 Series 02: DN40 and DN50 Series 01: DN 65...150 Three-port slipper valves PN6 VBF21.. Three-port slipper valves, PN6, flanged Grey cast iron EN-GJL-250 DN 40...150 k vs 25...820 m 3 /h Angle of rotation

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100

More information

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 00 to 40 VAC Torque min. 60 in-lb for control of damper surfaces up to 90 sq ft. Application For on/off and floating point control of dampers

More information

RVP-R- VAV controller. In explosion-proof version

RVP-R- VAV controller. In explosion-proof version VAV controller In explosion-proof version RVP-R- SMAY LLC / 29 Ciep³ownicza St. / 31-587 Cracow / Poland tel. +48 12 378 18 00 / fax. +48 12 378 18 88 / e-mail: info@smay.eu Intended use VAV control units

More information

VTZ variable speed Reciprocating compressors

VTZ variable speed Reciprocating compressors MAKING MODERN LIVING POSSIBLE Application guidelines VTZ variable speed Reciprocating compressors R404A, R507, R407C, R134a www.danfoss.com CONTENT VARIABLE SPEED COMPRESSORS... 4 Speed control...4 Advantages

More information

Electromotoric Actuators

Electromotoric Actuators 4 508 Electromotoric Actuators for slipper valves with 90 angle of rotation SQK34.00 SQK84.00 SQK34.00 operating voltage AC 230 V SQK84.00 operating voltage AC 24 V 3-position control signal Nominal angle

More information

SERIES 2000 GAS SAFETY SHUT OFF VALVE

SERIES 2000 GAS SAFETY SHUT OFF VALVE APPLICATION 2 Series 00 Solenoid Valves are Safety Shut-off or Control Valves for use on gases in gas families 1, 2 and and are also suitable for use with air within the valves pressure range - see specification.

More information

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating General Instructions DuraDrive MF4-653/MS4-653 Series Non-spring Return Rotary Electronic Damper Actuators 4 Vac Three-position/Modulating Description The DuraDrive direct-coupled, 4 Vac, non-spring return

More information

Rotary Limit Switches Driver FRM Series

Rotary Limit Switches Driver FRM Series Rotary Limit Switches Driver FRM Series TM Limit Switches Driver FRM Series Main Features The rotary limit switch is a device which allows you to control the movement of industrial and building machines.

More information

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA Butterfly valve with electrical actuator Description Position indicator Torque limiter Complete installation from factory - ready for installation Features: Spline driven one piece shaft connected to spherically

More information

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA Butterfly valve with electrical actuator Description Position indicator Torque limiter Complete installation from factory - ready for installation Features: Spline driven one piece shaft connected to spherically

More information

Combi valves PN 16 with flanged connections

Combi valves PN 16 with flanged connections 4 315 ACVATIX Combi valves PN 16 with flanged connections Pressure Independent Combi Valves VPF43.. With integrated pressure differential controller Valve body made of gray cast iron GJL-250 DN 50, DN

More information

technical brochure 3-/4-WAY ROTARY MIXING VALVES ARV ProClick ELECTRIC ACTUATORS ARM ProClick

technical brochure 3-/4-WAY ROTARY MIXING VALVES ARV ProClick ELECTRIC ACTUATORS ARM ProClick technical brochure 3-/4-WAY ROTARY MIXING VALVES ARV ProClick ELECTRIC ACTUATORS ARM ProClick 2017 3 Table of contents ADVANTAGES OF THE NEW ProClick GENERATION...4 INFORMATION ABOUT PACKAGING AND DELIVERY...5

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) HYDRAULIC FILTRATION Tank top return filters Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.1..1) Burst 16 bar (232 psi) (acc. to NFPA T 3.1..1) Housing Connection Ports:

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

Valves For Cryogenic Applications

Valves For Cryogenic Applications Valves For Cryogenic Applications Red Dragon has been supplying specialist valve products to all industries for over 20 years and we are proud of our reputation for service, quality and speed of delivery.

More information

JUMO heattherm Type Protection temperature limiter, as a panel-mounting thermostat Compensated for ambient temperature

JUMO heattherm Type Protection temperature limiter, as a panel-mounting thermostat Compensated for ambient temperature Page /5 JUMO heattherm Type 6003 Protection temperature limiter, as a panel-mounting thermostat Compensated for ambient temperature Brief description Thermostats control and monitor thermal processes.

More information

AXS 215S: Continuous actuator for unit valves, with stroke indicator

AXS 215S: Continuous actuator for unit valves, with stroke indicator AXS 215S: Continuous actuator for unit valves, with stroke indicator How energy efficiency is improved Reliable, precise actuation in efficient control systems Features Fitted to the valve using no force

More information

8000 Series Liquid Flow Meter

8000 Series Liquid Flow Meter PRODUCT DATA SHEET 8000 Series Liquid Flow Meter Advanced microprocessorbased flow measurement technology in a compact, leak-tight package. Flow ranges from 0.02 to 60 GPM / 0.1 to 227 LPM Accuracy of

More information

Nuova CEVA Automation. Via G.B. Signini 43. Briga Novarese (NO) ITALY Tel Fax

Nuova CEVA Automation. Via G.B. Signini 43. Briga Novarese (NO) ITALY Tel Fax General Features The rotary limit switch Driver FRS Series is a device used to control the movement of construction machines and industrial machines in general. It is connected via its shaft to a motor

More information

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators Datasheet 53lb-in (6 Nm), Non-Spring Return Damper Actuators Overview The direct-coupled fail-safe/failin-place electronic actuators are designed for modulating, two position, and floating control of laboratory

More information

MF /MS Series

MF /MS Series MF41-6153/MS41-6153 Series 24 Vac, Three-position/Modulating Non-spring Return Rotary Electronic Damper SmartX Actuators General Instructions Description The direct-coupled, 24 Vac, non-spring return electronic

More information

ACVATIX MiniCombiValves (MCV)

ACVATIX MiniCombiValves (MCV) 2 185 ACVATIX MiniCombiValves (MCV) Radiator valves featuring integrated differential pressure control for 2-pipe heating systems, fan coils and chilled ceiling systems VPD.. VPE.. Automatic flow limitation

More information

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI L8542965 03/2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 1 470 327 F A 500 825 B 243.5 2 C 445 210 15 ±5 205 92 50 2 3 4 I D2 D2 D1 5 T 6 D A

More information

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113 Data sheet ON/OFF zone valves (PN 16) AMZ 112, AMZ 113 Description AMZ 112/2-port valve 15-32 AMZ 112/2-port valve 40-50 AMZ 113/3-port valve The ON/OFF zone valves type AMZ 112 and AMZ 113 are typical

More information

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends Application Water-side control of heating and cooling systems for AHUs and water coils. Equal Percentage/

More information

Low Pressure Filter/Suction Filter Pi 270

Low Pressure Filter/Suction Filter Pi 270 Low Pressure Filter/Suction Filter Pi 270 Nominal pressure 10 bar (140 psi), up to nominal size 31 1. Features High performance filters for modern hydraulic systems Provided for pipe installation Modular

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE FEATURES The bronze ZEUS valve is intended for the automatic shutoff of networks of fluids. The full-bore inclined-seat body and the excellent flow-rate coefficients allow for very low pressure drops.

More information

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX 4 853 VPI45.. VPI45..Q with pressure test points ACVATIX Combi valves, PN 25 for rooms, zones, air handling units as well as small to medium heating, ventilation and air-conditioning systems VPI45.. VPI45..Q

More information

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

SOLENOID VALVES FOR REFRIGERATING SYSTEMS SOLENOID VALVES 17 SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive

More information

Electric Actuated 3-Way Ball Valves T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT

Electric Actuated 3-Way Ball Valves T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT Features Full Port direct mount 316 SS ball valve Functions as a diverter valve 1000 PSI working pressure at 100 F (38 C) Visual valve position

More information

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI L8542968 07/2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 1 458 250 A F 645 477 B 195 470 270 2 C 13 ±5 156 70 2 3 4 D2 R D2 I D1 T 5 W D H G R

More information

VPI45..Q with pressure test points. Combi valves, PN 25

VPI45..Q with pressure test points. Combi valves, PN 25 4 853 VPI45.. VPI45..Q with pressure test points ACVATIX Combi valves, PN 25 for rooms, zones, air handling units as well as small to medium heating, ventilation and airconditioning systems VPI45.. VPI45..Q

More information

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE FEATURES The stainless steel ARES valve is intended for the automatic shut-off of networks of fluids. The full-bore, inclined-seat body and the excellent flow-rate coefficients allow for very low pressure

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request) HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to

More information

Filtrec elements are tested also according to ISO 2942, ISO and ISO 3968

Filtrec elements are tested also according to ISO 2942, ISO and ISO 3968 HYDULIC FILTTION F-1 series Spin-on filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFP T 3.10.17) Burst 20 bar (290 psi) (acc. to NFP T 3.10.17) Connection Ports: 3/4 1 1/2

More information

The Powermatic User Guide Test Sieve Shaker

The Powermatic User Guide Test Sieve Shaker The Powermatic User Guide Test Sieve Shaker ISSUE 04-02 Contents Description Page 1 Setting Up: 2-8 Unpacking 2 Assembly 3-4 Levelling 4 Electrical Connections 5 Sieve Stacking 6-8 Operating Instructions

More information

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Version with handwheel Mounting and Operating Instructions EB 8039 EN Edition May 2016 Definition of signal

More information

Low Pressure Filter Pi 2000

Low Pressure Filter Pi 2000 Low Pressure Filter Pi 00 Nominal pressure 32/63 bar (460/900 psi), nominal size up to 400 according DIN 24550 1. Features.. High performance filters for modern hydraulic systems Provided for pipe installation

More information

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves VFB30 Series Issue Date February 1, 2016 20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves Low Torque Facilitates the use of smaller, less expensive directmount rotary-motion actuators Extends

More information

V5000. Globe Valves Series for Terminal Units. Product Bulletin

V5000. Globe Valves Series for Terminal Units. Product Bulletin V5000 Globe Valves Series for Terminal Units Product Bulletin The V5000 Valve Series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal unit

More information

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Electrically Released Brakes ERS VAR11-01 FT = 4100 N SM429gb - rev 06/11 S E R V I C E Electrically Released Brakes ERS VAR11-01 FT = 4100 N M A N U A L EC type certificate ABV 775/1 According to drawing 1 12 106946 TUV SUD Industrie Service WARNER ELECTRIC

More information

Compact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT

Compact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT Compact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT Features Industrial quality miniature actuator Full Port direct mount 3-way stainless steel ball valve

More information