Boiler room components 0459EN February 2018 Manual reset safety pressure switch
|
|
- Aldous Bell
- 5 years ago
- Views:
Transcription
1 0459EN February 08 Manual reset safety pressure switch K374Y00 Device intervention The device is activated when the preset locking pressure is reached; the heat generator stops when the electric contacts open. Reset The system can be restarted only by pushing the special reset button on the lower side of the case when the pressure drops by 0,5 bar below the setting value. Use Always avoid the following: Exceeding the expected room temperature (50 C) Exceeding the expected fluid temperature (0 C) Using unclean water Use in rooms with highly corrosive air Description Manual reset safety pressure switch to cut off the heat from the heat generator when reaching the system preset limit of maximum pressure (locking pressure). Device complying with directive PED 04/68/UE. Versions and product codes Product code Connection Control range K374Y00 /4 F 4,5 bar Technical data Fluid temperature range: 0 0 C Fluid class: Compatible fluids: water and glycol-based solutions (max. 50 %) Room temperature range: 0 50 C (RH 85 % max) Max. working pressure: 5 bar Control range: 4,5 bar Factory setting: 3 bar Reset min. differential: 0,5 bar Construction tolerance: ± 0,5 bar Nominal current: 6 A (resistive load) / 0 A (inductive load) Max. voltage: 50 V, 50/60 Hz Section of electric wires used: 0,75 4 mm² Protection class: IP44 Operation Setting The default locking pressure value is 3 bar. The value can be reset using a tool by turning the adjustment nut in the upper part of the case which includes a graduated scale on the side. CONENCTION /LOAD ADJUSTMENT NUT L N K374Y00 GRADUATED SCALE Installation The safaty pressure switch must be installed by qualified operators. The pressure switch is a device able to cut off the heat generator electric system. However, it cannot limit any pressure increase caused by heat inertia that may occur after the pressure switch is engaged. For such reason, devices preventing the pressure value from dropping below the maximum value admitted of 5 bar (es. safety valve) and the fluid temperature from dropping below 0 C (thermostat) must also be installed, in compliance with the safety standards. The pressure switch can be installed both horizontally and vertically screwing it on a /4 M (R, EN 06) threaded pipe or fitting after properly preparing the latter with oakum + putty, or PTFE, or anaerobic sealant (such materials guarantee sealing of the coupling when applied properly). The pipe connecting the pressure switch and the system must have a min. internal diameter of 8 mm if the pipe is shorter than a meter; 5 mm if the pipe is longer than a meter; 0 mm if it also serves other devices, whatever its length. The pressure switch must be installed with a n 7 wrench (recommended torque: 35 Nm). When the theoric short circuit current is greater than the max. nominal flow of the electric contacts, an electric current protection with intervention value lower or equal to 8 A must be installed before the pressure switch. Electric connections The K374Y00 pressure switch includes two electric contacts normally closed and insulated one from the other. Both contacts remain closed when the system is pressurized and both open when reaching the maximum locking pressure. LINE LINE L 50 V max. 6 (0) A N MANUAL RESET BUTTON
2 0459EN February 08 Manual reset safety pressure switch K374Y00 Start up Once installed, apply the anti-tampering seal on the adjustment screw to prevent modifications of the setting value by unauthorized people. Product specifications K374Y00 Manual reset safety pressure switch. /4 F connection. Locking pressure factory setting 3 bar. Control range: 4,5 bar. Manual reset button (differential 0,5 bar; tolerance ± 0,5 bar). Two contacts normally closed (wire section 0,75 4 mm²). Graduated scale visible from the outside. Nominal current 6 A (resistive load); 0 A (inductive load). Nominal voltage 50 V. Protection class IP44. Dimensions 04x00x60 mm (LxHxD). Room temperature range: 0 50 C. Fluid temperature range: 0 0 C. Max. working pressure: 5 bar. Complying with directive PED 04/68/UE. Before starting the pressure switch make sure: - Proper current protections have been installed where required - Electric connection has been executed in compliance with the applicable regulations - There are no water leaks from the hydraulic connection (pressure switch-system) Maintenance and inspections Every year: visual inspection to identify fluid leaks and/or corrosion. Every three years: verify proper contact opening. After every pressure switch intervention, verify there are no leaks both inside and outside the pressure switch, also removing the case. Also perform periodical mandatory inspections in compliance with the rules in force in the Country of installation. Every modification and/or repair performed on K374Y00 must be authorized in writing by Giacomini S.p.A. Failure to comply with any of the instructions above shall hold Giacomini S.p.A harmless from any civil and criminal responsibility. Dimensions B A C A [mm] B [mm] C [mm] Certifications Complying with directive PED 04/68/UE CE mark Additional information For more information, go to or contact our technical assistance service: ' * consulenza.prodotti@giacomini.com This document provides only general indications. Giacomini S.p.A. may change at any time, without notice and for technical or commercial reasons, the items included herewith. The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force. Giacomini S.p.A. Via per Alzo, San Maurizio d Opaglio (NO) Italy
3 0460EN February 08 Manual reset minimum pressure switch K374Y00 Device intervention The device is activated when the preset locking pressure is reached; the heat generator stops when the electric contacts open. Reset The system can be restarted only by pushing the special reset button on the lower side of the case when the pressure drops by 0,5 bar above the setting value. Use Always avoid the following: Exceeding the expected room temperature (50 C) Exceeding the expected fluid temperature (0 C) Using unclean water Use in rooms with highly corrosive air Description Manual reset minimum pressure switch to cut off the heat from the heat generator when reaching the system preset limit of minimum pressure (locking pressure). Device complying with directive PED 04/68/UE. Versions and product codes Product code Connection Control range K374Y00 /4 F 0,5,7 bar Technical data Fluid temperature range: 0 0 C Fluid class: Compatible fluids: water and glycol-based solutions (max. 50 %) Room temperature range: 0 50 C (RH 85 % max) Max. working pressure: 5 bar Control range: 0,5,7 bar Factory setting: 0,9 bar Reset min. differential: 0,5 bar Construction tolerance: ± 0,0 bar Nominal current: 6 A (resistive load) / 0 A (inductive load) Max. voltage: 50 V, 50/60 Hz Section of electric wires used: 0,75 4 mm² Protection class: IP44 Operation Setting The default locking pressure value is 0,9 bar. The value can be reset using a tool by turning the adjustment nut in the upper part of the case which includes a graduated scale on the side. ADJUSTMENT NUT MANUAL RESET BUTTON K374Y00 Installation The minimum pressure switch must be installed by qualified operators. The pressure switch is a device able to cut off the heat generator electric system. However, it cannot limit any pressure increase caused by heat inertia that may occur after the pressure switch is engaged. For such reason, devices preventing the pressure value from dropping below the maximum value admitted of 5 bar (es. safety valve) and the fluid temperature from dropping below 0 C (thermostat) must also be installed, in compliance with the safety standards. The pressure switch can be installed both horizontally and vertically screwing it on a /4 M (R, EN 06) threaded pipe or fitting after properly preparing the latter with oakum + putty, or PTFE, or anaerobic sealant (such materials guarantee sealing of the coupling when applied properly). The pipe connecting the pressure switch and the system must have a min. internal diameter of 8 mm if the pipe is shorter than a meter; 5 mm if the pipe is longer than a meter; 0 mm if it also serves other devices, whatever its length. The pressure switch must be installed with a n 7 wrench (recommended torque: 35 Nm). When the theoric short circuit current is greater than the max. nominal flow of the electric contacts, an electric current protection with intervention value lower or equal to 8 A must be installed before the pressure switch. Electric connections The K374Y00 pressure switch includes two electric contacts normally opened and insulated one from the other. Both contacts remain closed when the system is pressurized and both opened when reaching the minimum locking pressure. LINE LINE GRADUATED SCALE
4 0460EN February 08 Manual reset minimum pressure switch K374Y00 Start up Once installed, apply the anti-tampering seal on the adjustment screw to prevent modifications of the setting value by unauthorized people. Product specifications K374Y00 Manual reset safety pressure switch. /4 F connection. Locking pressure factory setting 0,9 bar. Control range: 0,5,7 bar. Manual reset button (differential 0,5 bar; tolerance ± 0,0 bar). Two contacts normally closed (wire section 0,75 4 mm²). Graduated scale visible from the outside. Nominal current 6 A (resistive load); 0 A (inductive load). Nominal voltage 50 V. Protection class IP44. Dimensions 04x00x60 mm (LxHxD). Room temperature range: 0 50 C. Fluid temperature range: 0 0 C. Max. working pressure: 5 bar. Complying with directive PED 04/68/UE. Before starting the pressure switch make sure: - Proper current protections have been installed where required - Electric connection has been executed in compliance with the applicable regulations - There are no water leaks from the hydraulic connection (pressure switch-system) Maintenance and inspections Every year: visual inspection to identify fluid leaks and/or corrosion. Every three years: verify proper contact opening. After every pressure switch intervention, verify there are no leaks both inside and outside the pressure switch, also removing the case. Also perform periodical mandatory inspections in compliance with the rules in force in the Country of installation. Every modification and/or repair performed on K374Y00 must be authorized in writing by Giacomini S.p.A. Failure to comply with any of the instructions above shall hold Giacomini S.p.A harmless from any civil and criminal responsibility. Dimensions B A C A [mm] B [mm] C [mm] Certifications Complying with directive PED 04/68/UE CE mark Additional information For more information, go to or contact our technical assistance service: ' * consulenza.prodotti@giacomini.com This document provides only general indications. Giacomini S.p.A. may change at any time, without notice and for technical or commercial reasons, the items included herewith. The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force. Giacomini S.p.A. Via per Alzo, San Maurizio d Opaglio (NO) Italy
5 Components for boiler room 046EN March 07 Pressure switches for autoclaves K374Y003, K374Y004 Regulation range To make the regulation, observe the figure below and the minimummaximum setting diagrams. Fully loosen the differential nut (). Adjust the minimum gap nut () to establish the contact closure value (pump start); turn clockwise to increase the start pressure, or anticlockwise to reduce it. Tighten the differential nut () until you obtain the required stoppage pressure. K374Y003 K374Y004 Description Pressure switch for use with cold water in autoclave systems (e.g. fire protection systems). The switch automatically regulates the starting and stopping of the circulator, on the basis of the pressure values set. The electric contacts are of the normally closed type. Minimum-maximum setting diagrams 6 K374Y003 Versions and product codes Product code Connection Regulation range Set pressure (factory calibration) K374Y003 /4 5 bar,4,8 bar K374Y004 /4 3 bar 5 7 bar Technical data Fluid temperature range 4 55 C Ambient temperature range C Protection degree IP44 Nominal voltage 500 V /4 F connection Three NC electric contacts (in brass alloy with Ag - Ni weld beading) Nominal current 6 A (resistive load); 0 A (inductive load) Max. working pressure K374Y003: 5 bar K374Y004: bar Set pressure (factory calibration) K374Y003:,4,8 bar K374Y004: 5 7 bar Regulation range K374Y003: 5 bar K374Y004: 3 bar Minimum differential K374Y003: 0,6 bar K374Y004:,5 bar Maximum differential K374Y003:,5 bar K374Y004: 5 bar Maximum setting (bar) Maximum setting (bar) Minimum setting (bar) K374Y Minimum setting (bar)
6 Components for boiler room 046EN March 07 Pressure switches for autoclaves K374Y003, K374Y004 Electrical connections LINE LINE LINE Dimensions B A C A [mm] B [mm] C [mm] Certifications Low Voltage Directive (LVD) 04/35/EU ROHS 0/65/EU EC mark Product specifications K374Y003 Pressure switch for use with cold water in autoclave systems. Factory calibration,4,8 bar. Regulation range 5 bar. /4 F connection. Three NC contacts (in brass alloy with Ag - Ni weld beading). Nominal current 6 A (resistive load); 0 A (inductive load). Nominal voltage 500 V. Protection degree IP44. Dimensions 04x00x60 mm (LxHxW). Operating temperature range C. Fluid temperature range 4 55 C. Max. working pressure 5 bar. Compliance with Low Voltage Directive (LVD) 04/35/EU; ROHS 0/65/EU. EC mark. K374Y004 Pressure switch for use with cold water in autoclave systems. Factory calibration 5 7 bar. Regulation range 3 bar. /4 F connection. Three NC contacts (in brass alloy with Ag - Ni weld beading). Nominal current 6 A (resistive load); 0 A (inductive load). Nominal voltage 500 V. Protection degree IP44. Dimensions 04x00x60 mm (LxHxW). Operating temperature range C. Fluid temperature range 4 55 C. Max. working pressure bar. Compliance with Low Voltage Directive (LVD) 04/35/EU; ROHS 0/65/EU. EC mark. Additional information For additional information please check the website or contact the technical service: ' * consulenza.prodotti@giacomini.com This pamphlet is merely for information purposes. Giacomini S.p.A. retains the right to make modifications for technical or commercial reasons, without prior notice, to the items described in this pamphlet. The information described in this technical pamphlet does not exempt the user from following carefully the existing regulations and norms on good workmanship. Giacomini S.p.A. Via per Alzo, San Maurizio d Opaglio (NO) Italy
Boiler room components 0459EN October 2013 Safety pressure switch with manual reset
0459EN October 03 Safety pressure switch with manual reset Installation The lockout pressure switch must be installed by qualified personnel. The pressure switch K374Y00 can be assembled either vertically
More informationActuator for mixing valves 0262EN March 2016
06EN March 06 07U758 -point floating actuator (connection M8 x,5 mm) for R98 and R98N mixing valves - K8 series 900 00 00A/ 800 006L/ Main features M8x,5 mm brass ring fixing to valve body. Immersion probe
More informationMetering systems 0483EN October 2013 Metering units for sanitary or service water
08EN October 0 Losses of Pressure The diagram showing losses of pressure is displayed below. For lower flow rate values, dashed lines are valid, due to the effect of the check valve spring.,00 Kv =, Δp
More informationMetering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series
Version A Version B GE552-1 Description The GE552-2 meters are thermal energy meters with double register and ultrasound,. They enable the measurement of energy used for heating and air-conditioning. They
More informationMetering systems 0368EN April /4 domestic water unit outputs
068EN pril 08 / domestic water unit outputs 07U98 Main characteristics Horizontal or vertical installation hut-off valves welded to water meter Dial with mechanical totalizers and index for partial consumptions
More informationManifolds and preassembled groups 0687EN November 2017 Modular manifolds for domestic water systems with outputs connection 1/2 or 3/4 Eurocone
0687N November 017 Modular manifolds for domestic water systems with outputs connection 1/ or /4 urocone R580 - R585 R580 R585 escription iacomini has introduced the R585 (with shut-off valve) and R580
More informationBolier room components 0870EN October 2017 Boiler room manifold with hydraulic separator
olier room components 0870E October 2017 oiler room manifold Description The boiler room manifold is a steel multi-function device including derivations for the primary and secondary circuits, automatic
More informationPUSH FITTINGS INSTA INST LLAT ALLA ION TION AND AND COMPONENTS COMPONENTS
PUSH FITTINGS INSTALLATION AND COMPONENTS SUMMARY 1. USE 1. TECHNICAL DATA 2. INSTALLATION WITH SYNTHETIC PIPES 3. INSTALLATION WITH COPPER PIPES 5. COMPONENTS 9. GUARANTEE June 2010 0135EN ISO 9001 0006/6
More informationOur new range of electromechanical pressure switches with fixed setting are compact, light and easy to install.
New Snap Disk Fixed setting pressure switches Compatible Refrigerants R22, R134a, R401, R402, R404, R407C, R410 and their lubricating oils, CO2 and R290 Our new range of electromechanical pressure switches
More informationON/OFF zone valves AMZ 112, AMZ 113
Data sheet ON/OFF zone valves AMZ 112, AMZ 113 Description Features: Indication of actual valve position; LED indication of turning direction; Manual valve turning mode enabled by a permanent clutch; No
More informationXL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL
XL/127-PLAST-SL - VERTICAL LEVEL GAUGES 5 WITH MIN LEVEL ELECTRICAL SIGNAL -Thermoplastic level gauges made of transparent polyamide with good mechanical resistance, are compatible with mineral oil, gasoline,
More informationVMH. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN EE
VMH Safety shut off valves for gas with hydraulic actuator DN65 DN300 delta-elektrogas.com EE175-0117 VMH Contents Description.. 3 Features.. 3 Functioning and application. 4 Special versions and optionals
More information2-position electric actuators with Ball valves VBZ ½...11/4
4 831.2 & VBZ ½...11/4 2-position electric actuators with Ball valves VBZ ½ 11/4 90 angle - Unidirectional rotation VBZ ½ 11/4 Electric rotary actuators for two-port ball valves Operating voltage AC 230
More informationON/OFF zone valves AMZ 112, AMZ 113
Data sheet ON/OFF zone valves AMZ 112, AMZ 113 Description The ON/OFF zone valves type AMZ 112 and AMZ 113 are typical used in connection with: Domestic and commercial central heating applications Domestic
More informationCALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB
otorised ball zone valves with -contact control -.. BY - series 00 0/ GB replaces 0/ GB unction The motorised zone valves permit automatically shutting off the medium in air conditioning or hydraulic and
More informationContent. 04 The Company. 13 Key to symbols. 22 Double walled tanks heads. 14 Dished heads table. 06 The catalogue and guide for the consultation
GENERAL CATALOGUE Content 04 The Company 06 The catalogue and guide for the consultation 08 Certifications 10 Technical notes 12 Materials 13 Key to symbols 14 Dished heads table 16 Dished head type D
More informationSolenoid Valve DF-SB-series
2/2-WAY SEMI-DIRECT OPERATED NORMALLY OPEN Solenoid Valve DF-SB-series The DF-DB is a semi-direct operated 2/2-way solenoid valve. The valve is normally open. The solenoid valves have an orifice of 16
More informationFiltrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181
Common HYDRAULIC FILTRATION Side wall mounting suction filters Technical Information Connection Ports: 1-1 1/4-1 1/2 BSP (other thread options on request) 1 1/2 SAE J518-3000/M12 Housing Materials: Cover:
More informationVML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE
VML Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 elektrogas.com EE162-1208 VML Safety solenoid valves for gas Slow opening and fast closing type Contents Description.. 2
More informationSolenoid Valve ST-IA-series
2/2-WAY INDIRECT OPERATED NORMALLY CLOSED Solenoid Valve ST-IA-series The ST-IA is an indirect operated 2/2-way solenoid valve. The valve is normally closed. The solenoid valves have an orifice of 13 to
More informationDuplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300
Duplex Filter Pi 241 Nominal pressure 40 bar (580 psi), nominal size up to 300 1. Features High performance filters for modern hydraulic, lubrication and fuel systems Modular system Compact design Minimal
More informationVMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE
VMH Safety shut off valves for gas with hydraulic actuator DN65 DN200 www. delta-elektrogas.com EE168-0513 VMH Contents Description.. 3 Features.. 3 Functioning and application. 4 Special versions and
More informationConnection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)
HYDRAULIC FILTRATION F4-DMD series In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1..1): F4-DMD/8/11: 7 bar (11 psi) F4-DMD1/3/4: 4 bar (8 psi) Housing Burst
More informationPressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T 3.10.5.1) Burst 330 bar (4800 psi) (acc. to NFPA T 3.10.5.1) Housing
More informationProduct bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings
Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings ST2 Ball valves in conjunction with spring return and non-spring return VA-Actuators Developed for HVAC applications
More informationBy-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane
HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports:
More informationSolenoid Valve DF-SA-series
2/2-WAY SEMI-DIRECT OPERATED NORMALLY CLOSED Solenoid Valve DF-SA-series The DF-DA is a semi-direct operated 2/2-way solenoid valve. The valve is normally closed. These valves have an orifice of 16 to
More informationConnection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working (acc. to NFPA T 3.1.5.1): F1-XD4/63/1: 1 bar (15 psi) F1-XD16/25/4: 8 bar (12 psi) Housing Burst (acc. to
More informationLiquid filled Thermometers
Liquid filled Thermometers Description and general specifications Liquid filled contact thermometers Operating instructions and maintenance Finished product quality control tests 02 02 05 06 1 Description
More informationPCS. Proof of closure switch for safety gas valves. delta-elektrogas.com EE
PCS Proof of closure switch for safety gas valves delta-elektrogas.com EE170 0613 PCS Proof of closure switch for safety gas valves Contents Description...3 Features...3 Functioning and application...4
More informationM-100 Adjustable flow switch with right-angle flow
M-100 Adjustable flow switch with right-angle flow Operating Instructions and Quick Start Guide Table of Contents Introduction 03 Operation 03 Storage and Handling 03 Installation Instruction 03 Specification
More informationSolenoid valves VZWP, servo-controlled
Key features and overview Function The solenoid valve VZWP-L- is a servo-controlled 2/2-way valve with solenoid coil. The solenoid valve is closed when de-energised. When energised, the differential pressure
More information8000 Series Liquid Flow Meters
PRODUCT DATA SHEET 8000 Series Liquid Flow Meters Advanced microprocessorbased flow measurement technology in a compact, leak-tight package Flow ranges from 0.2 to 227 LPM / 0.05 to 60 GPM Accuracy of
More informationCompact System NRGS 11-2 NRGS Original Installation Instructions English
Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive
More informationConnection Ports: 3/4 1 1/4 BSP (other thread options on request)
HYDRAULIC FILTRATION Medium pressure, in line spin-on filters Technical Information Pressure: Max working (acc. to NFPA T 3.10.17): FA-4-1x: 34,5 bar (500 psi) FA-4-21: 24 bar (348 psi) Burst (acc. to
More information3. Operating instructions: Minor 200
1. Technical specifications 3. Operating instructions: Minor 200 Copyright 2015 by Endecotts Ltd. 13 1. Setting up Technical specifications SIEVE SHAKER MODEL: Minor 200 General Information The Minor 200
More informationChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves
- Motorized 6-port Ball Valves Description NovoCon The and NovoCon are 6-port motorized ball valves that performs a diverting function between two water circuits in 4-pipe changeover system. This diverting
More informationSolenoid Valve ST-SA-series
2/2-WAY SEMI-DIRECT OPERATED NORMALLY CLOSED Solenoid Valve ST-SA-series The ST-SA is a semi-direct operated 2/2-way solenoid valve. The valve is normally closed. The body material can be brass or stainless
More informationDelta HE 35-XX, 55-XX
Installation and Operating Instructions Delta HE 35-XX, 55-XX 10.2009 Table of contents Table of contents EC Conformity Declaration Technical Data Delta HE 35 Technical Data Delta HE 55 Mounting Instructions
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationRotary Limit Switches Driver FRS Series
Rotary Limit Switches Driver FRS Series TM Limit Switches Driver FRS Series Main Features Driver rotary limit switch Series FRS is a device which allows you to control the movement of industrial and building
More informationListings and Approvals. G5 QR Gasket culus QR G5 SR Gasket culus, FM SR G5
Model Series Sprinklers Available with Solid, Perforated, or Gasket Standard Coverage, Concealed Pendent K2.8, 4.2, 5.6, & 8.0 (40, 60, 80, & 115 metric) Features Flat concealed cover plate available solid
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies
Type 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating instructions...2 2 Intended use...3 3
More informationPressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)
HYDRAULIC FILTRATION F8-D1 series In line medium pressure filters Technical Information Housing Pressure: Max working F8 D1x port size 1/ & 3/4 : 4 bar (6 psi) F8 D1x port size 1 : 3 bar (4 psi) F8 D14x:
More informationPressure Independent Control Valve
Pressure Independent Control Valve Rev. 4.0-06/06/2011 Technical manual Introduction The Pressure Independent Control Valve PICV is a combined constant flow limiter and full stroke, full authority equal
More information502 VALVE WITH UM1.5 ELECTRIC ACTUATOR. Model/Ref:
Model/Ref: 270090022000 www.lauridsenindustri.com CHARACTERISTICS The 502+UM1.5 is a 2-way brass ball valve dedicated to the automatic shut-off of non-corrosive common fluids: water, air, hydrocarbons,
More informationZB0050 / ZB0051 ZB0070 / ZB0071
Operating instructions Safety Rope Emergency Stop Switches UK ZB0050 / ZB0051 ZB0070 / ZB0071 7390877 / 02 08/2013 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4 2.2
More informationElectromotoric actuators
s 4 520 ACVATIX TM Electromotoric actuators SQL321B.. SQL361B.. For VKF42.. butterfly valves SQL321B.. Operating voltage AC 220 V, 2-position (SPDT) control signal SQL361B.. Operating voltage AC 220 V,
More informationPNEUMATIC PUMP Series
PNEUMATIC PUMP Series 3103... User and Maintenance Manual Original text translation TABLE OF CONTENTS 1. INTRODUCTION 2. GENERAL DESCRIPTION 3. PRODUCT-MACHINE IDENTIFICATION 4. TECHNICAL CHARACTERISTICS
More informationPressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )
HYDRAULIC FILTRATION In line medium pressure filters Technical Information Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T 3.10.5.1) Burst 840 bar (12200 psi) (acc. to NFPA T 3.10.5.1) Housing
More informationDuplex Filter Pi 4700
MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Duplex Filter Pi 4700 Nominal pressure up to 315/350 bar (4570/4980 psi), nominal size 40 up to 400
More informationOperating instruction Refrigerant Valves PS45
CDV II 3G Operating instruction Refrigerant Valves PS45 for flammable and safety refrigerants CDV..MVL.. One valve type for expansion, hot-gas and suction throttle applications Approved according to directive
More informationElectromotoric Actuators
4 506 Electromotoric Actuators for valves with 90 angle of rotation operating voltage AC 230 V 3-position control signal Nominal angle of rotation 90 Auxiliary switch and potentiometer for extra functions
More informationDuplex Filter Pi Features. Nominal pressure 25/63 bar (360/900 psi), nominal size up to 450
Duplex Filter Pi Nominal pressure 25/63 bar (360/900 psi), nominal size up to 450 1. Features.High performance filters for modern hydraulic systems Modular system Compact design Minimal pressure drop through
More informationPressure switch, high adjustability of switch differential
switch, high adjustability of switch differential For the process industry Model PSM-700, with robust aluminium case WIKA data sheet PV 35.05 Applications Pumps for process applications (e.g. water treatment,
More informationPremounted Midi Shunts
Application Midi Shunt 088U0181 - with one circuit Midi Shunt 088U0182 - with two circuits Midi Shunt 088U0183 - with three circuits The Danfoss floor heating midi shunt is a series of pre-mounted shunts
More informationSeries 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6
4 241 Series 02: DN40 and DN50 Series 01: DN 65...150 Three-port slipper valves PN6 VBF21.. Three-port slipper valves, PN6, flanged Grey cast iron EN-GJL-250 DN 40...150 k vs 25...820 m 3 /h Angle of rotation
More informationActuators for air dampers and control valves of oil burners
7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100
More informationGMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC
On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 00 to 40 VAC Torque min. 60 in-lb for control of damper surfaces up to 90 sq ft. Application For on/off and floating point control of dampers
More informationRVP-R- VAV controller. In explosion-proof version
VAV controller In explosion-proof version RVP-R- SMAY LLC / 29 Ciep³ownicza St. / 31-587 Cracow / Poland tel. +48 12 378 18 00 / fax. +48 12 378 18 88 / e-mail: info@smay.eu Intended use VAV control units
More informationVTZ variable speed Reciprocating compressors
MAKING MODERN LIVING POSSIBLE Application guidelines VTZ variable speed Reciprocating compressors R404A, R507, R407C, R134a www.danfoss.com CONTENT VARIABLE SPEED COMPRESSORS... 4 Speed control...4 Advantages
More informationElectromotoric Actuators
4 508 Electromotoric Actuators for slipper valves with 90 angle of rotation SQK34.00 SQK84.00 SQK34.00 operating voltage AC 230 V SQK84.00 operating voltage AC 24 V 3-position control signal Nominal angle
More informationSERIES 2000 GAS SAFETY SHUT OFF VALVE
APPLICATION 2 Series 00 Solenoid Valves are Safety Shut-off or Control Valves for use on gases in gas families 1, 2 and and are also suitable for use with air within the valves pressure range - see specification.
More informationDuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating
General Instructions DuraDrive MF4-653/MS4-653 Series Non-spring Return Rotary Electronic Damper Actuators 4 Vac Three-position/Modulating Description The DuraDrive direct-coupled, 4 Vac, non-spring return
More informationRotary Limit Switches Driver FRM Series
Rotary Limit Switches Driver FRM Series TM Limit Switches Driver FRM Series Main Features The rotary limit switch is a device which allows you to control the movement of industrial and building machines.
More informationButterfly valve with electrical actuator VFY-WA
Butterfly valve with electrical actuator Description Position indicator Torque limiter Complete installation from factory - ready for installation Features: Spline driven one piece shaft connected to spherically
More informationButterfly valve with electrical actuator VFY-WA
Butterfly valve with electrical actuator Description Position indicator Torque limiter Complete installation from factory - ready for installation Features: Spline driven one piece shaft connected to spherically
More informationCombi valves PN 16 with flanged connections
4 315 ACVATIX Combi valves PN 16 with flanged connections Pressure Independent Combi Valves VPF43.. With integrated pressure differential controller Valve body made of gray cast iron GJL-250 DN 50, DN
More informationtechnical brochure 3-/4-WAY ROTARY MIXING VALVES ARV ProClick ELECTRIC ACTUATORS ARM ProClick
technical brochure 3-/4-WAY ROTARY MIXING VALVES ARV ProClick ELECTRIC ACTUATORS ARM ProClick 2017 3 Table of contents ADVANTAGES OF THE NEW ProClick GENERATION...4 INFORMATION ABOUT PACKAGING AND DELIVERY...5
More informationPressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )
HYDRAULIC FILTRATION Tank top return filters Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.1..1) Burst 16 bar (232 psi) (acc. to NFPA T 3.1..1) Housing Connection Ports:
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationValves For Cryogenic Applications
Valves For Cryogenic Applications Red Dragon has been supplying specialist valve products to all industries for over 20 years and we are proud of our reputation for service, quality and speed of delivery.
More informationJUMO heattherm Type Protection temperature limiter, as a panel-mounting thermostat Compensated for ambient temperature
Page /5 JUMO heattherm Type 6003 Protection temperature limiter, as a panel-mounting thermostat Compensated for ambient temperature Brief description Thermostats control and monitor thermal processes.
More informationAXS 215S: Continuous actuator for unit valves, with stroke indicator
AXS 215S: Continuous actuator for unit valves, with stroke indicator How energy efficiency is improved Reliable, precise actuation in efficient control systems Features Fitted to the valve using no force
More information8000 Series Liquid Flow Meter
PRODUCT DATA SHEET 8000 Series Liquid Flow Meter Advanced microprocessorbased flow measurement technology in a compact, leak-tight package. Flow ranges from 0.02 to 60 GPM / 0.1 to 227 LPM Accuracy of
More informationNuova CEVA Automation. Via G.B. Signini 43. Briga Novarese (NO) ITALY Tel Fax
General Features The rotary limit switch Driver FRS Series is a device used to control the movement of construction machines and industrial machines in general. It is connected via its shaft to a motor
More informationDA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators
Datasheet 53lb-in (6 Nm), Non-Spring Return Damper Actuators Overview The direct-coupled fail-safe/failin-place electronic actuators are designed for modulating, two position, and floating control of laboratory
More informationMF /MS Series
MF41-6153/MS41-6153 Series 24 Vac, Three-position/Modulating Non-spring Return Rotary Electronic Damper SmartX Actuators General Instructions Description The direct-coupled, 24 Vac, non-spring return electronic
More informationACVATIX MiniCombiValves (MCV)
2 185 ACVATIX MiniCombiValves (MCV) Radiator valves featuring integrated differential pressure control for 2-pipe heating systems, fan coils and chilled ceiling systems VPD.. VPE.. Automatic flow limitation
More informationL /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI
L8542965 03/2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 1 470 327 F A 500 825 B 243.5 2 C 445 210 15 ±5 205 92 50 2 3 4 I D2 D2 D1 5 T 6 D A
More informationON/OFF zone valves (PN 16) AMZ 112, AMZ 113
Data sheet ON/OFF zone valves (PN 16) AMZ 112, AMZ 113 Description AMZ 112/2-port valve 15-32 AMZ 112/2-port valve 40-50 AMZ 113/3-port valve The ON/OFF zone valves type AMZ 112 and AMZ 113 are typical
More informationP2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends
P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends Application Water-side control of heating and cooling systems for AHUs and water coils. Equal Percentage/
More informationLow Pressure Filter/Suction Filter Pi 270
Low Pressure Filter/Suction Filter Pi 270 Nominal pressure 10 bar (140 psi), up to nominal size 31 1. Features High performance filters for modern hydraulic systems Provided for pipe installation Modular
More informationSG-B1 SERIES / SG-A1 SERIES
643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &
More informationBRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE
FEATURES The bronze ZEUS valve is intended for the automatic shutoff of networks of fluids. The full-bore inclined-seat body and the excellent flow-rate coefficients allow for very low pressure drops.
More informationVPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX
4 853 VPI45.. VPI45..Q with pressure test points ACVATIX Combi valves, PN 25 for rooms, zones, air handling units as well as small to medium heating, ventilation and air-conditioning systems VPI45.. VPI45..Q
More informationSOLENOID VALVES FOR REFRIGERATING SYSTEMS
SOLENOID VALVES 17 SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive
More informationElectric Actuated 3-Way Ball Valves T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT
T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT Features Full Port direct mount 316 SS ball valve Functions as a diverter valve 1000 PSI working pressure at 100 F (38 C) Visual valve position
More informationL /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI
L8542968 07/2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 1 458 250 A F 645 477 B 195 470 270 2 C 13 ±5 156 70 2 3 4 D2 R D2 I D1 T 5 W D H G R
More informationVPI45..Q with pressure test points. Combi valves, PN 25
4 853 VPI45.. VPI45..Q with pressure test points ACVATIX Combi valves, PN 25 for rooms, zones, air handling units as well as small to medium heating, ventilation and airconditioning systems VPI45.. VPI45..Q
More informationSTAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE
FEATURES The stainless steel ARES valve is intended for the automatic shut-off of networks of fluids. The full-bore, inclined-seat body and the excellent flow-rate coefficients allow for very low pressure
More informationPressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)
HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to
More informationFiltrec elements are tested also according to ISO 2942, ISO and ISO 3968
HYDULIC FILTTION F-1 series Spin-on filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFP T 3.10.17) Burst 20 bar (290 psi) (acc. to NFP T 3.10.17) Connection Ports: 3/4 1 1/2
More informationThe Powermatic User Guide Test Sieve Shaker
The Powermatic User Guide Test Sieve Shaker ISSUE 04-02 Contents Description Page 1 Setting Up: 2-8 Unpacking 2 Assembly 3-4 Levelling 4 Electrical Connections 5 Sieve Stacking 6-8 Operating Instructions
More informationMounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve
Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Version with handwheel Mounting and Operating Instructions EB 8039 EN Edition May 2016 Definition of signal
More informationLow Pressure Filter Pi 2000
Low Pressure Filter Pi 00 Nominal pressure 32/63 bar (460/900 psi), nominal size up to 400 according DIN 24550 1. Features.. High performance filters for modern hydraulic systems Provided for pipe installation
More information20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves
VFB30 Series Issue Date February 1, 2016 20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves Low Torque Facilitates the use of smaller, less expensive directmount rotary-motion actuators Extends
More informationV5000. Globe Valves Series for Terminal Units. Product Bulletin
V5000 Globe Valves Series for Terminal Units Product Bulletin The V5000 Valve Series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal unit
More informationElectrically Released Brakes ERS VAR11-01 FT = 4100 N
SM429gb - rev 06/11 S E R V I C E Electrically Released Brakes ERS VAR11-01 FT = 4100 N M A N U A L EC type certificate ABV 775/1 According to drawing 1 12 106946 TUV SUD Industrie Service WARNER ELECTRIC
More informationCompact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT
Compact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT Features Industrial quality miniature actuator Full Port direct mount 3-way stainless steel ball valve
More information