1 Exchanger Package May 2007
2 Table of Contents Scope of delivery...3 Assembly and installation...5 Spare parts list GB Page 2 Subject to alteration.
3 ECONET Exchanger Package, scope of delivery System overview: The Exchanger Package illustrated in the figure is delivered separately from the AHU and the ECONET pump unit. Basically, the Exchanger Package consist of one or two plate heat exchangers for connection to an external heating and/or cooling system. The pipework within the ECONET Exchanger Package is protected against rusting and insulated with Armaflex. The ECONET Exchanger Package comes with a stand for mounting on a flat floor Plate heat exchangers for supplementary heating/cooling 2. Pipes for ECONET pump unit 3. Shut-off valves 4. Drain valve, Filling valve 5. Specially designed stand 6. Expansion vessel with a safety valve 4 5 Every pipe is marked with the necessary connection information 8490 GB Page 3 Subject to alteration.
4 ECONET Exchanger Package, scope of delivery ECONET Exchanger Package: The ECONET Exchanger Package contsists of one or two plate heat exchangers for supplementary heating and/or cooling. The exchangers are made of AISI 316 stainless steel, brazed with pure copper. The typical pressure rating is 31 bar (450 psi), and the typical temperature rating is 225 C (437 F). The tubes are made of high-pressure steel, painted with anti-corrosion paint. These are then insulated with Armaflex. The heat exchanger package, the ECONET pump unit and the external pipework must not exceed a total pressure drop of 40 kpa for maximum liquid flow. If the pressure drop is higher (a long distance between the components), it should be taken into account when dimensioning the system. The pipe connections are male pipe threads from DN25 to DN50. The connections on the primary side against the plate exchangers are female pipe threads from DN25 to DN50. For dimensions DN65 and DN80, all connections are assembled flanges. The opening pressure for the delivered safety valve is 4.0 bar. All sizes of ECONET Exchanger Package come with a specially designed stand that is made for floor standing. The unit is delivered on a separate pallet. Packaging Suitable packaging protects the ECONET Exchange Package during transport. This is fully environmentally compatible, and should be taken for central disposal as a secondary raw material. EXP. VESSEL DIM. FOR MAX SYSTEM MAX B MAX H MAX D EU SIZE bb CONNECTION DN VOLUME litre mm mm mm 20, 21, 22, 30, , 33, 40, , 50, , 52, 53, , , 73, , H B D The picture shows size EU: GB Page 4 Subject to alteration.
5 ECONET Exchanger Package, assembly and installation General ECONET instructions can be found in ECONET manual This instruction only covers what is valid for the ECONET Exchanger Package. Installation instruction: The following shall be carried out on site by the plumbing/automation and electrical contractors. Unpacking Inspection of delivered equipment Check for signs of transit damage. Check that the product codes on the rating labels conform to your requirements. Check the delivered components against the bill of material. The code for the ECONET Exchanger Package can be found on one of the heat exchangers. Installation of necessary components for connecting an external energy source, as set out in the documentation. Filling and air purging of system. Equipment and controls for supplementary heating and cooling (SV30, SV50). Pipe installation: Installation of pipes between the ECONET Exchanger Package and the ECONET pump unit. Installation of the piping from the external energy source. Filling and air purging of the ECONET circuit and the external water system GB Page 5 Subject to alteration.
6 ECONET Exchanger Package, assembly and installation Pipe installation Connection to the pipe system should be carried out by the plumbing contractor. Installation normally includes: Installation of necessary components for connecting an external energy source, as set out in the documentation. The necessary components vary depending on the design of the object. Examples of external components are: Automatic air purging valve combined with a manual air purging valve Air purging valves for micro bubbles Filter Charging equipment Water trap Anti-freeze liquid Installation of the ECONET Exchanger Package to the ECONET pump unit. Mounting of control valves for supplementary heating and/or cooling. The installation of the ECONET Exchanger Package must not impose any loads on any pipes within the ECONET pump unit. The connection of the supplementary heating and/or cooling must be according to the plates mounted on the ECONET Exchanger Package and the ECONET pump unit. These plates indicate: Which of the plate heat exchangers are intended for heating and cooling. Inlet and outlet of the exchangers for primary heating and cooling. Pipes for connection to the ECONET pump unit. NOTE! In the ECONET Exchanger Package is disconnected from the ECONET unit, the Econet system might need an additional safety valve. NOTE! A purging valve must be fitted at the highest point in the system. IMPORTANT! Hold the pipe connections steady with a pipe wrench when tightening external pipes. Use flax (hemp) and paste for sealing the connections. Use sealings suited for anti-freeze liquids, such as etylen glycol mixtures. With the pipes installed correctly, the ECONET Exchanger needs to be protected from condensation with insulation on the pipes to/from the primary systems. The shut-off valves on ECONET Exchanger Package must be open when the system is running as normal. The ECONET Exchanger Package is build to stand on a flat floor. The ECONET Exchanger Package comes with a stand suitable for its size GB Page 6 Subject to alteration.
7 Spare parts list List of items that can be provided as spare parts. POS PART MAKER CODE SPARE PART NOTE 1 Plate heat exchanger SWEP FWG ordering code EURZ-05 dd=ff=5 eee=ggg=10 B5TH x 10 dd=ff=5 eee=ggg=14 B5TH x 14 dd=ff=5 eee=ggg=20 B5TH x 20 dd=ff=5 eee=ggg=30 B5TH x 30 dd=ff=8 eee=ggg=10 B8TH x 10 dd=ff=8 eee=ggg=20 B8TH x 20 dd=ff=8 eee=ggg=24 B8TH x 24 dd=ff=8 eee=ggg=30 B8TH x 30 dd=ff=8 eee=ggg=40 B8TH x 40 dd=ff=10 eee=ggg=10 B10TH x 10 dd=ff=10 eee=ggg=20 B10TH x 20 dd=ff=10 eee=ggg=30 B10TH x 30 dd=ff=10 eee=ggg=40 B10TH x 40 dd=ff=10 eee=ggg=50 B10TH x 50 dd=ff=10 eee=ggg=60 B10TH x 60 dd=ff=10 eee=ggg=70 B10TH x 70 dd=ff=15h eee=ggg=16 B15H x 16 dd=ff=15h eee=ggg=20 B15H x 20 dd=ff=15h eee=ggg=30 B15H x 30 dd=ff=15h eee=ggg=40 B15H x 40 dd=ff=16h eee=ggg=20 B16H x 20 dd=ff=16h eee=ggg=30 B16H x 30 dd=ff=16h eee=ggg=40 B16H x 40 dd=ff=16h eee=ggg=50 B16H x 50 dd=ff=16h eee=ggg=60 B16H x 60 dd=ff=16h eee=ggg=70 B16H x 70 dd=ff=16h eee=ggg=80 B16H x 80 dd=ff=16h eee=ggg=90 B16H x 90 dd=ff=16h eee=ggg=100 B16H x 100 dd=ff=16h eee=ggg=120 B16H x 120 dd=ff=25 eee=ggg=10 B25H x 10 dd=ff=25 eee=ggg=20 B25H x 20 dd=ff=25 eee=ggg=30 B25H x 30 dd=ff=25 eee=ggg=40 B25H x 40 dd=ff=25 eee=ggg=50 B25H x 50 dd=ff=25 eee=ggg=60 B25H x 60 dd=ff=25 eee=ggg=70 B25H x 70 dd=ff=25 eee=ggg=80 B25H x 80 dd=ff=28 eee=ggg=36 B28H x 36 dd=ff=28 eee=ggg=46 B28H x 46 dd=ff=28 eee=ggg=56 B28H x 56 dd=ff=28 eee=ggg=66 B28H x 66 dd=ff=28 eee=ggg=76 B28H x 76 dd=ff=28 eee=ggg=86 B28H x 86 dd=ff=28 eee=ggg=96 B28H x GB Page 7 Subject to alteration.
8 Spare parts list POS PART MAKER CODE SPARE PART NOTE dd=ff=28 eee=ggg=106 B28H x 106 dd=ff=28 eee=ggg=116 B28H x 116 dd=ff=28 eee=ggg=126 B28H x 126 dd=ff=28 eee=ggg=136 B28H x 136 dd=ff=35 eee=ggg=40 B35H x 40 dd=ff=35 eee=ggg=50 B35H x 50 dd=ff=35 eee=ggg=60 B35H x 60 dd=ff=35 eee=ggg=70 B35H x 70 dd=ff=35 eee=ggg=80 B35H x 80 dd=ff=35 eee=ggg=90 B35H x 90 dd=ff=35 eee=ggg=100 B35H x 100 dd=ff=46 eee=ggg=30 B120H x 30 dd=ff=46 eee=ggg=40 B120H x 40 dd=ff=46 eee=ggg=50 B120H x 50 dd=ff=46 eee=ggg=60 B120H x 60 dd=ff=46 eee=ggg=70 B120H x 70 dd=ff=46 eee=ggg=80 B120H x 80 dd=ff=46 eee=ggg=90 B120H x 90 dd=ff=46 eee=ggg=100 B120H x 100 dd=ff=46 eee=ggg=110 B120H x 110 dd=ff=46 eee=ggg=120 B120H x 120 dd=ff=46 eee=ggg=130 B120H x 130 dd=ff=46 eee=ggg=140 B120H x 140 dd=ff=56 eee=ggg=60 B56H x 60 dd=ff=56 eee=ggg=80 B56H x 80 dd=ff=56 eee=ggg=100 B56H x 100 dd=ff=56 eee=ggg=120 B56H x 120 dd=ff=56 eee=ggg=140 B56H x 140 dd=ff=56 eee=ggg=160 B56H x 160 dd=ff=56 eee=ggg=180 B56H x 180 dd=ff=70 eee=ggg=120 B427L x 120 dd=ff=70 eee=ggg=140 B427L x 140 dd=ff=70 eee=ggg=160 B427L x 160 dd=ff=70 eee=ggg=200 B427L x 200 dd=ff=72 eee=ggg=120 B427M1 x 120 dd=ff=72 eee=ggg=140 B427M1 x 140 dd=ff=72 eee=ggg=160 B427M1 x 160 dd=ff=72 eee=ggg=180 B427M1 x 180 dd=ff=72 eee=ggg=200 B427M1 x 200 dd=ff=72 eee=ggg=240 B427M1 x 240 FWG ordering code EURZ-05 2 Expansion vessel TA-Flex bb=20-41 TA-FLEX 12L TA No.: bb=42-60 TA-FLEX 25L TA No.: bb=62-84 TA-FLEX 40L TA No.: Shut-off valves bb=20-53 Ventim VM 4322 bb=62-85 Ventim VM Drain valve, Filling valve TA-SAV DN15 5 Safety valve TA TA No.: GB Page 8 Subject to alteration.
9 Group Brings Air to Life Group provides a full range of products and solutions for building ventilation, air treatment and industrial air movement. Head offices Buildings Air Climate AB Kung Hans väg 12 SE SOLLENTUNA Sweden t f Industry Air Movement Limited Tufnell Way COLCHESTER, CO4 5AR United Kingdom t +(0) f +(0) Sales Offi ces available Worldwide See our website for details. Due to a policy of continuous development and improvement the right is reserved to supply products which may differ from those illustrated and described in this publication. Certified dimensions will be supplied on request on receipt of order. FWG-Econet-Exchanger Package-GB CCJ
ECONET EXCHANGER PACKAGE EQRZ-05 AND LQRZ-05
ECONET EXCHANGER PACKAGE EQRZ-05 AND LQRZ-05 INSTALLATION AND MAINTENANCE INSTRUCTIONS CONTENTS PAGE SCOPE OF DELIVERY...1 ECONET EXCHANGER PACKAGE... 2 ASSEMBLY AND INSTALLATION...4 SPARE PARTS LIST...5
More informationECONET Fault and error manual
Fault and error manual March 2009 Contents Basic data to get started...3 A Alarms 1. Ice alarm, GT 42...4 2. Frost alarm, GT 41...4 3. Pump alarm, P 40...5 4. Pressure alarm, GP 40...5 5. Liquid, temperature
More informationECONET premium EQ STAZ-74, EQRZ-05, EQL STYZ-74, LQRZ-05 » INSTALLATION AND MAINTENANCE MANUAL. liquid-coupled heat exchanger ECONET premium
AIR COMFORT AIR TREATMENT 9603 GB 2015.05.20 ECONET premium EQ STAZ-74, EQRZ-05, EQL STYZ-74, LQRZ-05» INSTALLATION AND MAINTENANCE MANUAL Content page liquid-coupled heat exchanger ECONET premium Integrated
More informationECONET PREMIUM EQ STAZ-74, EQRZ-05, EQL STYZ-74, LQRZ-05
ECONET PREMIUM EQ STAZ-74, EQRZ-05, EQL STYZ-74, LQRZ-05 INSTALLATION AND MAINTENANCE MANUAL Content Page Liquid-coupled heat exchanger ECONET Premium Integrated pump and energy exchange package. Safety
More informationThree-port slipper valves PN10, female-threaded
4 232 SERIES 02 Three-port slipper valves PN10, female-threaded VBI31.. Three-port slipper valves, PN10, female-threaded Grey cast iron EN-GJL-250 DN 20 40 k vs 6.3...25 m 3 /h Angle of rotation 90 Female-threaded
More informationButterfly valves PN6, PN10, PN16
4 131 ACVATIX Butterfly valves PN6, PN10, PN16 VKF41.. Grey cast iron housing EN-GJL-2 DN 40 200 k vs 4000 m 3 /h For fitting between PN 6, PN 10, PN 16 counter-flanges to ISO 7005 Metallic tight-closing
More informationSeries 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6
4 241 Series 02: DN40 and DN50 Series 01: DN 65...150 Three-port slipper valves PN6 VBF21.. Three-port slipper valves, PN6, flanged Grey cast iron EN-GJL-250 DN 40...150 k vs 25...820 m 3 /h Angle of rotation
More informationSolar Thermal. Grant Solar Pump Station Installation & Servicing Instructions
Solar Thermal Grant Solar Pump Station Installation & Servicing Instructions Part No. DOC 96. Rev 02. October 2012 Important Note Important Note for Installers The Pump Station supplied with your Grant
More informationECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES
ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES TECHNICAL AND INSTALLATION DOCUMENTATION STOKVIS ENERGY SYSTEMS UNIT 34 CENTRAL PARK ESTATE 34 CENTRAL PARK ESTATE WEST
More informationPressure independent balancing and control valve For ON/OFF control
KT 512 Pressure independent balancing and control valve For ON/OFF control Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE High-performing and compact, these
More informationECONET PREMIUM START UP ON SITE ROUTINE FOR ECONET START UP: THE ECONET SYSTEM SHALL BE STARTED UP BY AUTHORIZED PERSONEL PROTOCOL BEFORE START UP
ECONET PREMIUM ROUTINE FOR ECONET START UP: 1. Protocol, before start up 2. 10 most important issues. Start up protocol THE ECONET SYSTEM SHALL BE STARTED UP BY AUTHORIZED PERSONEL PROTOCOL BEFORE START
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More information2-port and 3-port valves with T-bypass PN 16
4 854 2-port valves 3-port valve with T-bypass CVTIX 2-port and 3-port valves with T-bypass PN 16 VVP45..S VMP45..S ronze CC499K valve body DN 10 and DN 15 k vs 0.63 2.5 m 3 /h Externally threaded connections
More informationReversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)
Simple, reliable efficient heat pump! Equipped with µconnect controller HFC R410A CERTITA CERTIFIED * Cooling capacity: 5 to 16.5 kw Heating capacity: 6 to 19 kw *except 75HT OPTION HEAT PUMP HEATING (30/35
More informationTwo-port seat valves with male thread, PN16
4 363 Two-port seat valves with male thread, PN6 VVG4... Two-port seat valves with male thread, PN6 Bronze Rg5 DN5... DN50 mm (½"... 2") k vs 0.63... 40 m 3 /h Stroke 20 mm Can be equipped with actuators
More informationDA 50. Differential pressure controllers Adjustable set-point
DA 50 Differential pressure controllers Adjustable set-point IMI TA / Differential pressure controllers / DA 50 DA 50 These differential pressure controllers for heating and cooling systems are particularly
More information3-Port Seat Valves with Male Thread, PN 16
4 463 3-Port Seat Valves with Male Thread, PN 16 VXG41 Use Media Bronze CC491K (Rg5) valve body DN 15DN 50 k vs 1640 m 3 /h Flat sealing connections with external thread G B to ISO 228/1 Sets of ALG 3
More informationBRAZED PHE. Performance - Economy - Reliability - Compact
BRAZED PHE Performance - Economy - Reliability - Compact Head office: PO Box 230, Watford, Hertfordshire WD18 8JY Tel: +44(0)1923 232335 Fax: +44 (0)1923 230266 Email: mail@hrs.co.uk Website: wwwhrshevac.co.uk
More information2-Port and 3-Port Zone Valves PN 16
4 842 2-port valves VVI46.15 to VVI46.25 3-port valves VXI46.15 to VXI46.25 2-Port and 3-Port Zone Valves PN 16 VVI46... VXI46... Hot-pressed brass valve body (EN1982); VXI46.25T: bronze CC491K (Rg5) max.
More informationRWBa. ROOM CONTROL EQUIPMENT Electronic control of cooling and heating. RWBa
ROOM CONTROL EQUIPMENT Electronic control of cooling and heating. ROOM CONTROL EQUIPMENT RWBa For sequential control of heating and cooling, or cooling/ heating only. Electromechanical actuators provide
More informationSTAF-SG. ANSI flanges. Balancing valves DN
STAF-SG ANSI flanges Balancing valves DN 20-400 IMI TA / Balancing valves / STAF-SG ANSI flanges STAF-SG ANSI flanges A flanged, ductile iron balancing valve that delivers accurate hydronic performance
More informationSeries 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6
4 241 Series 02: DN40 and DN50 Series 01: DN 65...150 Three-port slipper valves PN6 VBF21... Three-port slipper valves, PN6, flanged Grey cast iron EN-GJL-250 DN 40...150 k vs 25...820 m 3 /h Angle of
More informationTA-PILOT-R. Differential pressure controllers Pilot operated differential pressure controller with adjustable set-point
TA-PILOT-R Differential pressure controllers Pilot operated differential pressure controller with adjustable set-point IMI TA / Differential pressure controllers / TA-PILOT-R TA-PILOT-R The TA-PILOT-R
More information2-port seat valves PN16 with flanged connection
4 330 Acvatix 2-port seat valves PN16 with flanged connection VVF40.. Grey cast iron EN-GJL-250 valve body DN 15...150 k vs 1.9...315 m 3 /h Can be equipped with SAX..-electromotoric or SKD..-, SKB..-
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationComponents for central heating
01 01 Components for central heating Booster units and spare parts 18 Hydraulic separator and spare parts 21 Dirt separators - Deaerators 23 By-Pass differential valve - Air separator units 32 Filling
More informationifan Copford Box Range
Setting the Standard for Energy Management ifan Copford Box Range Energy Management by demand Introduction The ifan is designed to offer environmental management through a controllable solution for the
More informationThese installation and maintenance instructions must be read in full and completely understood before the installation!
These installation and maintenance instructions must be read in full and completely understood before the installation! 1. General information on the installation and maintenance instructions These instructions
More informationCombi valves PN 16 with flanged connections
4 315 ACVATIX Combi valves PN 16 with flanged connections Pressure Independent Combi Valves VPF43.. With integrated pressure differential controller Valve body made of gray cast iron GJL-250 DN 50, DN
More informationSTAF-SG. ANSI flanges. Balancing valves Size 3/4-16
STAF-SG ANSI flanges Balancing valves Size 3/4-16 IMI TA / Balancing valves / STAF-SG ANSI flanges STAF-SG ANSI flanges A flanged, ductile iron balancing valve that delivers accurate hydronic performance
More informationZONE CONTROLE / 2-WAY
ZONE CONTROLE / 2-WAY PRESSURE INDEPENDENT BALANCING AND CONTROL VALVE ON/OFF High-performing and compact, these pressure-independent temperature control valves for variable flow heating and cooling systems,
More information3-port seat valves PN16 with flanged connection
4 440 Acvatix 3-port seat valves PN16 with flanged connection VXF41.. Grey cast iron EN-GJL-250 valve body DN 15...150 k vs 1,9...300 m 3 /h Can be equipped with SAX..-electromotoric or SKD..-, SK..- and
More information2-port seat valves PN25 with flanged connection
4 373 Acvatix 2-port seat valves PN25 with flanged connection VVF52.. Nodular cast iron EN-GJS-400-8-LT valve body DN 5...40 k vs 0.6...25 m 3 /h Can be equipped with SAX..-electromotoric or SKD..- or
More informationTHE NEW GENERATION MIXING VALVES. NEWS LK 840 ThermoMix 2.0 LK 841 ThermoMix 2.0
THE NEW GENERATION MIXING VALVES NEWS LK 840 ThermoMix 2.0 LK 841 ThermoMix 2.0 LK Armatur, A One- Stop Supplier Please visit www.lkarmatur.se, to find more information on our product range. ON OUR WEBSITE
More informationNAF Duball DL Pocket Ball Valves TECHNICAL BULLETIN FCD NFENTB A4 11/17
NAF Duball DL Pocket Ball Valves TECHNICAL BULLETIN FCD NFENTB463-00-A4 /7 NAF Duball DL Pocket Ball Valves FCD NFENTB463-00-A4 /7 Primary characteristics The NAF Duball DL Pocket Valve is the pulp and
More informationDN [ ] DN [ ] Functional data Media Cold and hot water, water with glycol up to max. 50% vol.
Technical data sheet R6..W..-S8 Characterised control valves, -way, with PN 16 flange For closed cold and hot water systems For modulating water-side control of air purification and heating systems Air
More informationunderfloor heating PRODUCTS FOR UNDERFLOOR HEATING
underfloor heating PRODUCTS FOR UNDERFLOOR HEATING Table of Contents LK 420 Minishunt... 3 LK 421 Manifold Shunt... 4 LK 422 Manifold Shunt... 5 Spare Parts and Accessories... 6 LK 430 Manifold... 7 LK
More informationSAMPLE COOLER and SLUDGE TRAP OPERATION & MAINTENANCE MANUAL
SAMPLE COOLER and SLUDGE TRAP OPERATION & MAINTENANCE MANUAL PLEASE RECORD THE FOLLOWING DATA (Information is located on the product label or packing slip) Product: Model No: Serial No: Installation Date:
More informationVBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN
4 24 Series 02: DN40 and DN50 Series 0: DN 65...50 Three-port slipper valves PN6 VBF2.. Three-port slipper valves, PN6, flanged Grey cast iron EN-GJL-250 DN 40...50 k vs 25...820 m 3 /h Angle of rotation
More information3-port seat valves PN16 with flanged connection
4 430 Acvatix 3-port seat valves PN16 with flanged connection VXF40.. Grey cast iron EN-GJL-250 valve body DN 15 150 k vs 1.9 315 m 3 /h Can be equipped with SQX.. electromotoric or SKD..-, SK..- and SKC..-
More information2-port ball valves with flanged connection, PN25
s 4 120 ACVATIX 2-port ball valves with flanged connection, PN25 VAF51.. Gray cast iron EN-GJL-250 (HT250) valve body DN 65...150 k vs 63...360 m 3 /h Angle of rotation 90 Flange connection to ISO 7005-2
More informationMicro Gear Fuel Pump System
Micro Gear Fuel Pump System User Manual V1.5 ECOTRONS LLC COPY RIGHTS ECOTRONS ALL RIGHTS RESERVED Note: If you are not sure about any specific details, please contact us at info@ecotrons.com. Index Page
More informationSTAF, STAF-SG. Balancing valves PN 16 and PN 25 DN
STAF, STAF-SG Balancing valves PN 16 and PN 25 DN 20-400 IMI TA / Balancing valves / STAF, STAF-SG STAF, STAF-SG A flanged, cast iron (STAF) and ductile iron (STAF-SG) balancing valve that delivers accurate
More informationTITAN FLOW CONTROL, INC.
PREFACE: TITAN FLOW This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI)Full Body Swing Check Valves. To ensure efficient and safe
More informationNEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions
More informationUsers Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions
Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions 600 S 56 th Street #9 Chandler, AZ 85226 Phone: 480-507-6478 Fax: 480-838-2232
More informationHERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs
HERZ 7217 V Integral Fixed Orifice Control Valve Data sheet 7217 V, Issue 1011 Size in mm STRÖMAX Fig No DN L Lm Rp H SW kv kvs TS-V LF 1 7217 50 15 83 28,5 1/2 41 27 0,07-0,45 0,48 TS-V MF 1 7217 59 15
More information3-port seat valves, external thread, PN16
4 464 3-port seat valves, external thread, PN6 VXG44.. ronze CC49K (Rg5) valve body DN 5..DN 40 k vs 0.25..25 m 3 /h Flat sealing connections with external thread G to ISO 228- Sets of ALG..3 screwed fittings
More informationResidential R.O. components
Residential R.O. components WATER TREATMENT COMPONENTS 1,8 RESIDENTIAL CSM MEMBRANES 2015 10-01-01-EN 1,8 RESIDENTIAL CSM MEMBRANES Ref. Model Name RE1810-30 DA050A RE1810-50 RE1812-35 DA050 DA051 DA052
More informationButterfly valves, PN6, PN10, PN16
4 131 Butterfly valves, PN6, PN10, PN16 VKF41... Butterfly valves for fitting between counter-flanges Nominal pressures PN6, PN10, PN16 Nodular cast iron GG-20 / GG-25 Metallic tight-closing (end-stop)
More informationVERTICAL SERIES BOOSTER PUMPS
VERTICAL SERIES BOOSTER PUMPS Stainless Steel Vertical Multistage Centrifugal Pump The Webtrol V Series Vertical multistage pumps offer technically advanced designs to meet market demands including hot
More informationInstallation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC
Installation, Operation & Service Manual PPL Bag Filter Housings Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Read all instructions before installation or operation of equipment. Failure
More information3-port seat valves PN10 with flanged connection
4 420 cvatix 3-port seat valves PN10 with flanged connection VXF31.. Grey cast iron EN-GJL-250 valve body DN 15 150 k vs 2.5 315 m 3 /h Can be equipped with SX..-electromotoric or SKD..-, SK..- and SKC..-
More informationTechnical Information Liquiline System CAT810
TI01138C/07/EN/02.16 71341422 Products Solutions Services Technical Information Control of sample preparation by the Liquiline System CA80 or a time control system Automatic sample preparation system for
More information3-Port Seat Valves with Male Thread, PN 16
6 3-Port Seat Valves with Male Thread, PN 6 VXG ronze CC9K (Rg5) valve body DN 5DN 0 k vs 02525 m 3 /h Flat sealing connections with external thread G to ISO 228/ Sets of ALG 3 screwed fittings with threaded
More information2-port and 3-port ball valves PN 40
s 4 211 VAI61.. VBI61.. ACVATIX TM 2-port and 3-port ball valves PN 40 with internally threaded connections VAI61.. VBI61.. Brass UNS C35330 (DZR) ball valve body DN 15...50 k vs 1...63 m 3 /h Internally
More informationButterfly valves PN 16
s 4 119 ACVATIX TM Butterfly valves PN 16 VKF42.. Gray cast iron or nodular cast iron valve body DN 50...600 k vs 65...37,000 m 3 /h For fitting with PN 16 counter-flanges to ISO 7005 Tight-closing in
More information2-Port Seat Valves with Flange, PN 25
4 7 2-Port Seat Valves with Flange, PN 25 VVF52... Nodular cast iron EN-GJS-400-8-LT valve body DN 5...40 k vs 0.6...25 m /h Can be equipped with SQX- electromotoric or SKD...- or SKB...- electrohydraulic
More informationOwner s Manual WARNING
Filter Housing Models: AWP20C-V, AWP30C-V, AWP32B-V. Overview: Owner s Manual VIQUA offers a variety of housing sizes and styles in durable, molded polymer that defies rust and corrosion, and ensures a
More informationVenturi Flow Meter Installation and Operation Manual
Venturi Flow Meter Installation and Operation Manual 357-EN Please read and save these instructions. Installation Procedures The Proper Method of Installing a Venturi Meter Caution: - This is a high quality
More informationEach pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.
General 1 Model MS 9-2-60 expandable/modular duplex central vacuum system consisting of two Becker or approved equivalent VT4.25 vacuum pumps mounted on a common skid with expandable automatic alternating
More informationFlowCon SH mm. Adjustable Dynamic Self Balancing Valve SPECIFICATIONS
FlowCon SH 50-150mm Adjustable Dynamic Self Balancing Valve SPECIFICATIONS Pressure rating: 4000 kpa / 580 psi Temperature rating, media: -20 C to +120 C / -4 F to +248 F Material: - Diaphragm: Hydrogenated
More informationWhisper Tech, WhisperGen, Personal Power Station, and WhisperGen Personal Power Station are registered trademarks of Whisper Tech Limited.
Whisper Tech reserves the right to revise or change product specifications at any time. This publication describes the state of this product at the time of its publication and may not reflect the product
More information3-port seat valves PN6 with flanged connection
4 410 cvatix 3-port seat valves PN6 with flanged connection VXF21.. Grey cast iron EN-GJL-250 valve body DN 25...100 k vs 1.9...160 m 3 /h Can be equipped with SQX.. electromotoric or SKD..-, SK..- and
More informationOPERATION AND INSTALLATION
OPERATION AND INSTALLATION RESIDENTIAL SOLAR PUMP STATION» SE FLOWSTAR PUMP STATION Table of Contents 1 For your safety 1.1 About this manual 1.2 Designated use 1.3 Qualification of the installer 1.4 Hand-over
More informationCooling system components, removing and installing
Page 1 of 40 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
More informationAlfa Laval Toftejorg Rotary Spray Heads MultiMidget & MultiMagnum
4102-0008 Instruction Manual Alfa Laval Toftejorg Rotary Spray Heads MultiMidget & MultiMagnum Covering: Standard versions IM-TE91A748-EN5 First published: 2014-04 ESE02830-EN5 2016-02 Original manual
More informationInstallation Operation Maintenance
Worcester 53 / 54 Series PN 16 / 25 / 40 reduced bore ball valves Installation Operation Maintenance WCENIM0010-01 Original Instructions Copyright All rights reserved. No part of these instructions may
More informationSTAF, STAF-SG. Balancing valves PN 16 and PN 25 DN
STAF, STAF-SG Balancing valves PN 16 and PN 25 20-400 IMI TA / Balancing valves / STAF, STAF-SG STAF, STAF-SG A flanged, cast iron (STAF) and ductile iron (STAF-SG) balancing valve that delivers accurate
More informationPositive displacement flowmeter for continuous flow measurement
8070 Positive displacement flowmeter for continuous flow measurement High accuracy Medium with high viscosity Mounting and dismounting of the electronics by a quarter-turn Connection to Bürkert devices
More information3-Port Seat Valves with Flange, PN 6
4 410 3-Port Seat Valves with Flange, PN 6 VXF21... Grey cast iron EN-GJL-250 valve body DN 25... k vs 1.9...160 m 3 /h Can be equipped with SQX... electromotoric or SKD...-, SK...- and SKC...- electrohydraulic
More informationRegulated Hose Supply Installation, Operation & Maintenance Manual
Regulated Hose Supply Installation, Operation & Maintenance Manual For Models: BA-MS-320-00 BA-MS-320-05 BA-MS-320-20 BA-MS-325-00 BA-MS-325-05 BA-MS-325-20 BA-SFS-320-000 BA-SFS-320-012 BL-005 1/30/2007
More information3-Port Seat Valves with Flange, PN 10
4 420 3-Port Seat Valves with Flange, PN 10 VXF31... Grey cast iron EN-GJL-250 valve body DN 15 150 k vs 2.5 315 m 3 /h Can be equipped with SQX... electromotoric or SKD...-, SK...- and SKC...- electrohydraulic
More informationEach pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.
1 General Model MS300-4-530 expandable/modular central vacuum system consisting of 4 Becker or approved equivalent VTLF2.250 vacuum pumps mounted on a common skid with expandable automatic alternating
More informationMaintenance Instruction for double-acting pneumatic cylinder type EC
Maintenance Instruction for double-acting pneumatic cylinder type EC This maintenance instruction is an instruction for maintenance on the double-acting pneumatic cylinders type EC. The instruction shall
More informationThe pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.
General Model MS150-4-150 expandable/modular central vacuum system consisting of 4 Becker or approved equivalent KVX3.140-400 vacuum pumps mounted on a common skid with expandable automatic alternating
More informationA E R Z E N S C R E W C O M P R E S S O R S
A E R Z E N S C R E W C O M P R E S S O R S New Aerzen Screw Compressor Units Delta Screw Generation 5 Intake volume flows from 270 m³/h up to 2.600 m³/h A E R Z E N E R M A S C H I N E N F A B R I K G
More information3-port seat valves PN40 with flanged connection
4 482 DN 15 and DN 25 DN 40 150 Acvatix 3-port seat valves PN40 with flanged connection VXF61.. Cast steel GP240GH valve body DN 15...150 k vs 1.9...300 m 3 /h Can be equipped with SKD.., SK.. and SKC..
More informationCondensate Drain Valve AK 45. Original Installation Instructions English
Condensate Drain Valve AK 45 EN English Original Installation Instructions 810467-03 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED (Pressure
More informationDESCRIPTION 9.4 G 3/4"M
DESCRIPTION Six-way ballvalve for HVAC 4 pipes applications to automatically carry out the winter-summer change-over or, potentially, to manage radiant ceilings, fan coils and chilled beams. DIMENSIONS
More informationLIFT-O-FLEX Lift-O-Turn LIFTER USER MANUAL. We re here for you. PLACE SERIAL NUMBER LABEL HERE. Have Questions?
PLACE SERIAL NUMBER LABEL HERE LIFT-O-FLEX Lift-O-Turn LIFTER USER MANUAL DOCUMENT ID: 01022018 Have Questions? We re here for you. R ON I READ BEFORE YOU BEGIN It is important that you read and understand
More informationInstallation Operation Maintenance
Worcester 18 / 19 Series Class 150 / 300 multiway valves Installation Operation Maintenance WCENIM0009-02 Original Instructions Copyright All rights reserved. No part of these instructions may be reproduced,
More informationCooling water Chilled water Low temperature hot water C Water with anti-freeze (max. 50%vol.)
7ZRSRWVDWYDOYV 33 Female-threaded 7ZRSRWVDWYDOYV33IPDOWKDGG RGXODFDVWLRQYDOYERG\** 'PPò N YVP K 6WRNPP :LWKPDQXDORYLGKDQGZKO )RIPDOWKDGG5SòFRQQFWLRQVR )RILWWLQJEWZQ3R3IODQJV &DQEILWWGZLWKDFWXDWRW\SV646646R646
More informationDXP 100 Air Cooled Condenser
Air Cooled Condenser Applied for CERTIFY-ALL DX COOLERS PRESENTATION The coolers are designed for outdoor applications. All technical data are based on different mixtures of cooling media i.e.ethylene
More informationSerie Ekoflux S. Flanged balancing valve. Application fields. Regulation. Ekoflux.S_GB_22/04/2015 HEATING CONDITIONING
Serie Ekoflux S Flanged balancing valve Ekoflux.S_GB_/0/0 Application fields CONDITIONING HEATING www.brandoni.it Serie Ekoflux S The valves in the series EKOFLUX balance the flow in main circuits or single
More information2-port and 3-port terminal unit valves PN16
4 847 2-port valves VVP47..(S) 3-port valves VXP47.. cvatix 2-port and 3-port terminal unit valves PN16 3-port valves with bypass VMP47..(S) VVP47..(S) VXP47.. VMP47..(S) ronze valve body CC491K (Rg5)
More informationPositive displacement flowmeter
Positive displacement flowmeter Configurable outputs: one or two transistor output(s) and single or dual 4...20 ma current output(s) Removable backlit display of flow rate and/or 2 two totalized volumes
More informationInstallation and operation manual Dual plate check valve LK product no: and
Installation and operation manual Dual plate check valve LK product no: 300702 and 301702 Article no: 74520 Revision: 1 This manual is valid for the following LK product numbers: Wafer type, multiflange
More information2- and 3-port valves with flanged connections, PN 16
4 403 VVF42.. VVF42..K VXF42.. ACVATIX 2 and 3port valves with flanged connections, PN 16 From the largestroke valve line VVF42.. VVF42..K VXF42.. Performance valves for medium temperatures from 10 150
More informationSAMPLE CYLINDERS. Sample Cylinders & Accessories. Spun End Cylinders. Ultra-Seal Constant Pressure Cylinders. VP Series Cylinder Valves
SAMPLE CYLINDERS T H E S O L U T I O N F O R G A S S A M P L E S T O R A G E Sample Cylinders & Accessories ISO 9001:2008 Certified Quality System Spun End Cylinders Ultra-Seal Constant Pressure Cylinders
More informationButterfly valves PN 16
s 4 119 ACVATIX TM Butterfly valves PN 16 VKF42.. Gray cast iron or nodular cast iron valve body DN 50...600 k vs 65...37,000 m 3 /h For fitting with PN 16 counter-flanges to ISO 7005 Tight-closing in
More informationTECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS
TECHNICAL CATALOGUE DISTRIBUTION TEC ITAP SpA, founded in Lumezzane (Brescia) in 972, is currently one of the leading production companies in Italy of valves, fittings and distribution manifolds for plumbing
More information2- and 3-port valves with flanged connections, PN 6
4 401 VVF22.. VXF22.. ACVATIX 2 and 3port valves with flanged connections, PN 6 From the largestroke valve line VVF22.. VXF22.. Performance valves for medium temperatures from 10 130 C Valve body of grey
More informationUsers Manual Certified Series Direct Drive Pump 1-7 LPM
Users Manual Certified Series Direct Drive Pump 1-7 LPM Safety, Operating, Installation, and Maintenance Instructions 600 S 56 th Street #9 Chandler, AZ 85226 Phone: 480-507-6478 Fax: 480-838-2232 www.fogco.com
More informationDatA sheet. D-2011/05/ Date: 02/2013. Type TSA2 CNG. Inline breakaway Coupling. for car fuelling stations FUTURE. TECHNOLOGY. TODAY.
DatA sheet D-2011/05/00160-3-3 Date: 02/2013 Type TSA2 CNG Inline breakaway Coupling for car fuelling stations FUTURE. TECHNOLOGY. TODAY. DATA sheet General Description Receptacle insert Eccentric actuator
More informationHGX6/ S Engine: V Y/YY -3-50Hz PW Refrigerant: R404A, R507
Performance data Application: Refrigeration & AC Refrigerant R404A, R507 Power supply 50 Hz, 400 V Supply frequency 50 Hz Evaporating temperature 5.0 C Evaporating pressure (abs.) 7.06 bar Condensing temperature
More informationadvanced FLOW engineering Instruction Manual P/N: Make: Dodge Model: 2500 / 3500 Year: Engine: I-6 5.9L (td)
advanced FLOW engineering Instruction Manual P/N: 42-22011 DFS780 PRO Make: Dodge Model: 2500 / 3500 Year: 1998.5-2002 Engine: I-6 5.9L (td) 1 Label Qty. Description Part Number A 1 Fuel Manifold Assembly
More informationTechnical Specification
Technical Specification Agss Plant Product Description Active anesthetic gas scavenging systems should be designed to safely remove exhaled anesthetic agents from the operating environment and dispose
More informationFluid Coil Installation, Operation and Maintenance
Bulletin FCO&I 001 REV A Fluid Coil Installation, Operation and Maintenance Monika Hewlett Packard Company [Pick the date] FLUID COIL INSTALLATION, OPERATION & MAINTENANCE GUIDELINES Fluid Coil Installation,
More informationGeo-Prime Tank. Table of Contents. Installation, Operation & Maintenance Instructions AFCG1PT Revision: 7/3/14. Replacing a Pump 12
Geo-Prime Tank Installation, Operation & Maintenance Instructions AFCG1PT Revision: 7/3/14 Table of Contents General Description 3 Installation 4 Flushing and Purging 7 Initial Start-up 9 Replacing a Pump
More information