Hold / Abort Switches

Size: px
Start display at page:

Download "Hold / Abort Switches"

Transcription

1 Hold / Abort Switches Features The Hold and Abort switch modules complement the Ex-3000 Series Extinguishing panels. The modules comply with the requirements of BS The switches are easy to wire and multiple units can be daisy-chained together on an input circuit. A range of finishes is available White, Stainless Steel and Brass Trims. Alternatively, the unit can be supplied in an IP65 rated enclosure. The standard units can be surface mounted or semi-flush mounted onto standard 3½ electrical boxes. The IP65 unit is surface mounted. Simple to install Range of finishes available Surface or flush mount IP65 Option Complies with BS requirements

2 Specifications & Ordering: Models, Sales Order Parts: Exp HOLD Switch, Plastic Enclosure Exp HOLD Switch, Stainless Steel Trim Cover Plate Exp HOLD Switch, Brass Trim Cover Plate Exp HOLD Switch, IP65 Plastic Enclosure Exp Exp Exp Exp ABORT Switch, Plastic Enclosure ABORT Switch, Stainless Steel Trim Cover Plate ABORT Switch, Brass Trim Cover Plate ABORT Switch, IP65 Plastic Enclosure Applications / Limitations: For use in Gas Extinguishing installations to hold or abort the release of the extinguishant. Compatibility: Compatible with the Ex-3000 Series Gas Extinguishing Panel and Remote Status Indicator Panel input circuits. Item Specification Details Dimensions (Plastic Unit) Overall 87 x 87 x 41, Back Box 87 x 87 x 29 Dimensions (Metal Trim Unit) Overall 87 x 87 x 47, Back Box 87 x 87 x 44 Minimum Depth behind cover 35mm Dimensions (IP65 Unit) Overall 72 x 72 x 62 (including switch actuator) Environmental Class Indoor -5 C to 40 C Humidity 95 % Max End-of-Line Resistance 6800 Ω SW #1 Active Resistance 470 Ω Maximum Operating Voltage 30V DC As our policy is one of constant product improvement the right is therefore reserved to modify product specifications without prior notice

3 Table of Contents Page 1 INSTALLATION STANDARD UNIT Surface Mount Flush Mount IP65 UNIT WIRING STANDARD UNIT IP65 UNIT

4 1 Installation The unit is supplied pre-assembled mounted onto its back box. 1.1 Standard Unit The assembly comprises of: Plastic Cover Back Box 87 x 87 x 29 Cover Metal Trim Cover Back Box 87 x 87 x 44 Metal Trim Plate Mounting Plate The switch plate assembly snaps into position in either the plastic cover or the mounting plate. To remove the metal cover trim plate, place a small screwdriver into the recess underneath the trim plate at the bottom and carefully prise off. The metal trim snaps into the mounting plate. Plastic Cover Assembly Metal Trim Cover Assembly Back Box Back Box Cover Mounting Plate Surface Mount The back box fixing points are shown on the diagram opposite. Sufficient breakout sections are provided for the wiring. 63mm 42mm Flush Mount The plastic cover assembly or the mounting plate / metal trim assembly can be mounted onto a standard 3½ electrical box minimum depth 35mm. 4

5 1.2 IP65 Unit The assembly comprises of a two-part IP65 enclosure with integral switch block and actuator. A resistor end-ofline card is used to provide the end-of-line and activation resistors. The cover incorporates the switch actuator. Captive fixing screws are included. Cover 72 x 72 x 22 The back box incorporates the switch block pre-wired to the end-of-line module. Knockouts are provided top and bottom. Two fixing holes are provided in the back of the box. Back Box 72 x 72 x 29 2 Wiring 2.1 Standard Unit The 2-way terminal block provides a simple way of correctly terminating the switch input circuits of the Ex-3000 Series Extinguishing Control Panel / system. The switch plate assembly module consists of a plastic plate with pre-printed text, switch assembly, printed circuit card and connector. The printed circuit board snaps onto the switch assembly it should not be prised off. The normal 6800Ω end-of-line resistor supplied with the panel is not used as this is automatically included on the printed circuit board. TO PANEL If multiple switch units are to be connected to the circuit, the units can be daisy-chained on the circuit. A break-off tab (to remove the end-of-line resistor) must be removed on all modules except the last module on the circuit see below. TO PANEL Remove Break-off TAB to remove 6800 ohm end-of-line resistor Leave Break-off TAB in place 5

6 2.2 IP65 Unit The switch block is pre-wired to the EOL Module terminal block. Wiring to the panel is identical to the standard unit but uses a pluggable terminal block. The switch block is prewired to the required terminals of the pluggable terminal block. TO PANEL + COM 6K8 470 Internal Wiring to Switch Block 6

7 USER NOTES

8 Doc Number: Revision: First Issued: 01A 2013-mm-dd Advanced Electronics Ltd Moorland Way, Cramlington, Northumberland, NE23 1WE UK Tel: +44 (0) Fax: +44 (0) Web:

PSU EN54-4 Power Supplies

PSU EN54-4 Power Supplies PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in

More information

Product Data Sheet. Damper Interface. Features

Product Data Sheet. Damper Interface. Features Damper Interface Product Data Sheet Features Damper Motor drive and limit switch monitoring integrated into a single unit Dual limit switch inputs for confirmation of damper-fully-open and damperfully-closed

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

PSM72H Push-Button Start Module

PSM72H Push-Button Start Module Capricorn Controls DA02PSM72H1-2 Data & Application Note Page 1 of 6 PSM72H Push-Button Start Module Genset Controls - Timers/Monitors/Trips - Battery Charging Spares & Accessories - Custom Products Ultra

More information

Zone 1 Linear Range - Installation Guide

Zone 1 Linear Range - Installation Guide Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text

More information

Series 270. Commercial Miniature 5/8" (16mm) Diameter Composition Variable Resistors. Electrical and Mechanical Specifications.

Series 270. Commercial Miniature 5/8 (16mm) Diameter Composition Variable Resistors. Electrical and Mechanical Specifications. Series 270 Commercial Miniature 5/8" (16mm) Diameter Composition Variable Resistors Miniature 5/8" (16mm) size Versatile mounting styles: bushing twist tab bend tab snap-in PC bracket solder lug or PC

More information

3D PRINTER. Pack 09. Anything you can imagine, you can make! 3D technology is now available for you at home! BUILD YOUR OWN

3D PRINTER. Pack 09. Anything you can imagine, you can make! 3D technology is now available for you at home! BUILD YOUR OWN BUILD YOUR OWN Pack 09 Anything you can imagine, you can make! 3D PRINTER Compatible with Windows 7 & 8 Mac OS X 3D technology is now available for you at home! www.model-space.com BUILD YOUR OWN 3D PRINTER

More information

NexT Range Large sheet steel enclosures

NexT Range Large sheet steel enclosures Large sheet steel enclosures 8 Large sheet steel enclosures The NexT Range is the optimum choice for particularly harsh environments. The stainless steel design of the NexT Range can face up to the toughest

More information

APEM LPI series Front or rear mounting Illuminated or non-illuminated Flexibility of marking Meeting the requirements of EN81-70 Ø 35 mm actuator

APEM LPI series Front or rear mounting Illuminated or non-illuminated Flexibility of marking Meeting the requirements of EN81-70 Ø 35 mm actuator APEM LPI series Front or rear mounting Illuminated or non-illuminated Flexibility of marking Meeting the requirements of EN81-70 Ø 35 mm actuator Distinctive features and applications Common features Large

More information

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS Design The Sabre VRN2a is a compact SF6 insulated Vacuum Ring Main Unit (RMU). The unit can be mounted to the smallest distribution transformer or be sited in

More information

Underfloor to desk 231

Underfloor to desk 231 Technical information Underfloor to desk 231 Series 507 Powertrack Series 507 Powertrack is an underfloor busbar system rated at 63Amp maximum. It is available in Standard or CE (Clean Earth) versions.

More information

Installation & Operating Instructions

Installation & Operating Instructions Underfloor Heating Controller Cat. No TPT1 Installation & Operating Instructions Installation & Operating Instructions Main unit (front view) Slots for snap-on bezel Indicator light shows green when mains

More information

It s time to get connected with

It s time to get connected with It s time to get connected with The essence of quality NEW See pag e6 PRATLEY products and P NUTS are distributed exclusively in the UK by: Cable Connectors Ltd Product Brochure Aluminium Alloy (Corrosion

More information

KCR1. Kiln Controller Handbook. Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom

KCR1. Kiln Controller Handbook. Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom KCR1 Kiln Controller Handbook Issue: a b Date: 04Sep2008 05Sep2008 Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom Tel: 01782 535915 Tel:

More information

GS-IOB-120/240VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions

GS-IOB-120/240VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions GS-IOB-120/240VAC Input/Output/Bypass Assembly Installation Instructions Purpose This document provides information on how to install the Input/Output/Bypass Assembly needed for a 120/240 Vac configuration

More information

... A Vital Part of Connection World CMPTER. Cable Connectors PCB Connectors Assembly Instructions Mounting Holes MCX CONNECTORS

... A Vital Part of Connection World CMPTER. Cable Connectors PCB Connectors Assembly Instructions Mounting Holes MCX CONNECTORS ... A Vital Part of Connection World Cable Connectors PCB Connectors s Mounting Holes MCX CONNECTORS COPYRIGHT ELECTRONICS 0 MCX Series Coaxial Connectors DESCRIPTION MCX connector are developed in Europe

More information

Globe Valve Model Description Globe Valve, Hot Water or Steam Applications

Globe Valve Model Description Globe Valve, Hot Water or Steam Applications Description VG series accurately regulate the flow of water or steam in response to the demand of a controller in heating,ventilating and air conditioning systems. These valves are available in normally

More information

Cut out PRODUCT CODE HANDLE BODY FINISH MATERIAL MODUL. 5 mm Double bit 8 mm Square 9 mm Triangular Button. Stainless steel dust cap (Keyed alike) 03

Cut out PRODUCT CODE HANDLE BODY FINISH MATERIAL MODUL. 5 mm Double bit 8 mm Square 9 mm Triangular Button. Stainless steel dust cap (Keyed alike) 03 ROD-LATCH SYSTEM LINEAR HANDLE LOCK 204 V : 1 With mechanism Cut out Ergonomic and modern design Locking and unlocking by linear movement Suitable for inside & outside gasketing applications Swing handle

More information

SENSORS: Temperature sensors and switches

SENSORS: Temperature sensors and switches SENSORS: Temperature sensors and switches The following temperature sensors are available - Temperature sensor (40 C 120 C) - Temperature sensor (50 C 150 C) - Temperature sensor with warning contact (40

More information

Rittal CM Compact System Enclosures

Rittal CM Compact System Enclosures Rittal CM Compact System Enclosures Compact class = Top class: Infinite possibilities R Compact enclosure on the outside, Top enclosure on the inside! Index Convincing details... 3 5 Compact system enclosures

More information

Installation Manual Local Ventilation System with Heat Recovery Type e² - Please hand out to user -

Installation Manual Local Ventilation System with Heat Recovery Type e² - Please hand out to user - Installation Manual Local Ventilation System with Heat Recovery Type e² - Please hand out to user - Contents Page: About this manual, safety instructions 1 Technical Specifications, Disposal 1 Dimensional

More information

11812 NE 116th Street TEL: Kirkland, WA USA FAX: TECHNICAL DATA SHEET AMFLOW A2-ACM ACTUATOR (BELT DRIVE)

11812 NE 116th Street TEL: Kirkland, WA USA FAX: TECHNICAL DATA SHEET AMFLOW A2-ACM ACTUATOR (BELT DRIVE) A & H Enterprises, Inc. Amflow 11812 NE 116th Street TEL: +425.883.4040 Kirkland, WA 98034 USA FAX: +425.823.1962 www.amflow.com EMAIL: ah@amflow.com TECHNICAL DATA SHEET AMFLOW A2-ACM ACTUATOR (BELT DRIVE)

More information

Precision Load Cells. The World of Precision Made Force Transducers. A world of experience TEST AND MOTION SIMULATION

Precision Load Cells. The World of Precision Made Force Transducers. A world of experience TEST AND MOTION SIMULATION Precision Load Cells The World of Precision Made Force Transducers With many years of experience in the Precision Load Cells field, Servotest has been working to develop testing equipment that exceeds

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45 46

More information

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2 Fieldbus Segment Protector Features Assembly 4... 10 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur Segment Protector in Zone 2/Div. 2 Instruments in Zone

More information

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz GR24A-5 / -7 GR24A-5 Rotary actuator for rotary valves GR24A-7 Rotary actuator for rotary valves Nominal torque 40Nm Nominal voltage AC/DC 24V Control Open-close echnical data Electrical data Nominal voltage

More information

ComfortPoint Programmable Lon, VAV/Unitary Controllers

ComfortPoint Programmable Lon, VAV/Unitary Controllers ComfortPoint Programmable Lon, VAV/Unitary Controllers Controller Model Programmable Type Universal Inputs (UI) Table 1. Controller configurations. Digital Inputs (DI) PRODUCT DESCRIPTION INSTALLATION

More information

3 CE-Conformity. General information. Signal lamps. 3-2 Signal lamps

3 CE-Conformity. General information. Signal lamps. 3-2 Signal lamps Signal lamps General information Signal Lamps with integral lamps/s The soldered lamps/s without base cannot be replaced. Signal Lamps with lamp socket An integral lamp socket allows replacement of lamps/s

More information

INSTRUCTIONS. Power Panel. Installation Instructions

INSTRUCTIONS. Power Panel. Installation Instructions Overview LuXout Shade 18 Output - For use with LuXout Shades NOTICE: This power supply is built-in fan on/off control circuit. Fan automatically works according to working temperature. SHOCK HAZARD Risk

More information

GS-IOB-230VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions

GS-IOB-230VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions GS-IOB-230VAC Input/Output/Bypass Assembly Installation Instructions Purpose This document provides information on how to install the Input/Output/Bypass Assembly needed for a single-phase configuration

More information

Pressure Transmitter

Pressure Transmitter FCO318 Differential Pressure Transmitter Accuracy 0.25% of reading Ultra low pressure measurement Wide span adjustment 2-wire ma, 3-wire or 4-wire voltage output Two configurable relays and bi-colour LED

More information

I Ex-control stations I

I Ex-control stations I Type 11 83 Type 11 82 Type 11 81 Technical data Ex-control stations Type 11 81 I Type 11 82 I Type 11 83 Marking accd. to 9/9/EC II 2 G Ex ed ib m IIC T6 II 2 D Ex td A21 IP66 T80 C EC-Type Examination

More information

UB-1PN Universal Pneumatic Button

UB-1PN Universal Pneumatic Button UB-1PN Universal Pneumatic Button ADA for operation We protect the things that protect you. NOTES It is important to read, understand and follow all instructions provided with this product. It is the installer

More information

Installation, Care and Maintenance Instructions. Optiflush OP1 Battery and OP2 Mains Versions

Installation, Care and Maintenance Instructions. Optiflush OP1 Battery and OP2 Mains Versions Installation, Care and Maintenance Instructions Optiflush OP1 Battery and OP2 Mains Versions The Prestex Optiflush Congratulations on buying the Prestex Optiflush Urinal Flush Controller. The product utilises

More information

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations. Conformity has been

More information

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY 222 W. Memorial Road, Oklahoma City, OK 73114-2317 Phone: 1-800-624-7697 Fax: 405-755-8425 www.magpowr.com E-mail: magpowr@magpowr.com INSTRUCTION MANUAL MODEL PS-24 24 VDC POWER SUPPLY All of the information

More information

MCX Connectors Specifications Flexible Cable Semi-Rigid Cable Panel Mount PCB Mount... 22

MCX Connectors Specifications Flexible Cable Semi-Rigid Cable Panel Mount PCB Mount... 22 Section Index Connectors Specifications... 17 Flexible Cable... 19 Semi-Rigid Cable... 20 Panel Mount... 21 PCB Mount... 22 Other Information Assembly Instructions... 176 Cable Assembly... 166 Cable Information...

More information

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1 Model 340i / 680i / 1220i DC drive product manual HG102938 iss 8 1 Sprint Electric Limited, Arundel, UK Tel. +44 (0)1903 730000 Fax. +44 (0)1903 730893 Email. info@sprint-electric.com www.sprint-electric.com

More information

Direct Communication Module

Direct Communication Module Installation Instructions Direct Communication Module (Catalog Number 1747-DCM) Inside...................................... page For More Information.............................. 3 Hazardous Location

More information

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators Installation D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators IMPORTANT: The D- Series actuators are intended to control equipment under normal operating conditions. Where failure

More information

USER S MANUAL. Installation, Operation, & Maintenance

USER S MANUAL. Installation, Operation, & Maintenance 1-800-899-0553 assuredautomation.com SM Series Motorized Ball Valves On/Off & Modulating Electric Actuators USER S MANUAL Installation, Operation, & Maintenance Assured Automation 263 Cox Street, Roselle,

More information

Know-how makes the difference. Limit Switches

Know-how makes the difference. Limit Switches Know-how makes the difference Limit Switches With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product development

More information

Lighting for: Community Housing

Lighting for: Community Housing Lighting for: Community Housing First Edition www.lampslighting.co.uk Lynx Surface Ceiling Luminaires Lynx LED Surface Ceiling Luminaires Features: IP44 (resists dirt ingress & splash proof) Energy efficient

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:

More information

GE Sensing & Inspection Technologies

GE Sensing & Inspection Technologies GE Sensing & Inspection Technologies Modus Model RPM-1 Room Pressure Monitor Installation and Setup Guide 1. GENERAL The RPM-1 monitors either positive or negative room pressures (see the Datasheet for

More information

GL1200T Cut & Seal. (GL1200 Seal only)

GL1200T Cut & Seal. (GL1200 Seal only) GL INSTRUMENTS & Operating Instructions Safe Seal Cut & Seal Welder for Filter Sacks GL1200T Cut & Seal (GL1200 Seal only) For industrial use only Important Safety & Operating Instructions Please read

More information

MODEL RPM10/RPM20 (-LON)/RPM20-CC PRESSURA ROOM PRESSURE MONITOR

MODEL RPM10/RPM20 (-LON)/RPM20-CC PRESSURA ROOM PRESSURE MONITOR MODEL RPM10/RPM20 (-LON)/RPM20-CC PRESSURA ROOM PRESSURE MONITOR INSTALLATION INSTRUCTIONS WARNING The Model RPM10, RPM20 (-LON) and RPM20-CC Room Pressure Monitors must be wired to 24 VAC only. Wiring

More information

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3 SA/6/1/EN/3 Fire Dampers Type FDF Compliant to SABS (193:2004) TROX (South Africa) (Pty) Ltd. 10 Wigford Road Masons Mill Pietermaritzburg Tel. +27 (0)33 398 1006 Fax. +27 (0)33 398 1100 email : pmb@troxsa.co.za

More information

Self Contained Electro-Hydraulic Power Packs For Valve Actuators

Self Contained Electro-Hydraulic Power Packs For Valve Actuators Global Presence for Peace of Mind Self Contained Electro-Hydraulic Power Packs For Valve Actuators Superior Performance Throughout the Full Operational Range Continuous Power from.1w Lowest Cost Solution

More information

Differential Temperature Controller

Differential Temperature Controller 3 337 Synco 100 Differential emperature Controller R27 Differential temperature controller for solar storage systems. Compact design with two 2-position control output AC 24 230 V. Use Plant types: Solar

More information

2. Use Extraction Tool (contact extraction tool). Insert releasing tip into the REAR of the. cavity between the spring and center wall of the

2. Use Extraction Tool (contact extraction tool). Insert releasing tip into the REAR of the. cavity between the spring and center wall of the Twin Leaf PC Board Edge Connectors are designed for wire to pc board applications. To meet specific circuit requirements, housings are supplied (1) to be assembled using contacts, retaining springs, and

More information

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42) Paddle Style [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /4B to B. Wide range of

More information

DOMINO Series surface mounting IP55

DOMINO Series surface mounting IP55 Series surface mounting IP55 SERIES CONSUMER UNITS SURFACE MOUNTING VERSION - IP55 REFERENCE STANDARDS International standard IEC 60670 (989) and the Modification (994) Part : General requirements for

More information

ASSEMBLING THE 15 INCH FLUSH MOUNT TOUCH SCREEN DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN

ASSEMBLING THE 15 INCH FLUSH MOUNT TOUCH SCREEN DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN 18 (457 mm) 12 39/64 (320 mm) 3 1/2 (89 mm) 1 13/32 (36 mm) 19 (483 mm) 3 5/8 (92 mm) 7/64 3 mm) 1 13/32 (36 mm) 23 53/64 (605 mm) 20 3/4 (527 mm) 12

More information

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions Solar Thermal Grant Solar Pump Station Installation & Servicing Instructions Part No. DOC 96. Rev 02. October 2012 Important Note Important Note for Installers The Pump Station supplied with your Grant

More information

Hydro-Wiper A. Data Logger Controlled Anti-Fouling Wiper for the Seapoint Turbidity Meter. Installation and Operation Manual

Hydro-Wiper A. Data Logger Controlled Anti-Fouling Wiper for the Seapoint Turbidity Meter. Installation and Operation Manual Hydro-Wiper A Data Logger Controlled Anti-Fouling Wiper for the Seapoint Turbidity Meter Installation and Operation Manual Contents 1. Hydro-Wiper at a glance... 1 Features... 2 2. Hydro-Wiper specifications...

More information

TotalPac 3 Deluge system Pneumatic release

TotalPac 3 Deluge system Pneumatic release (Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a deluge system trim totally preassembled, pre-wired and factory tested. All electrical and

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO.: C3100L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3100L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200

More information

MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER

MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER INSTALLATION INSTRUCTIONS WARNING The Model RPC30 (-LON) Room Pressure Controller must be wired to 24 VAC only. Wiring the unit to 110 VAC will cause

More information

Flex Amplifiers Installation Instructions

Flex Amplifiers Installation Instructions Flex Amplifiers Installation Instructions Introduction This publication describes the installation procedure for the 4100U and 4100ES Flex Amplifiers. This product is compatible with both 4100U and 4100ES

More information

RollBeam. telescopic linear actuator

RollBeam. telescopic linear actuator RollBeam telescopic linear actuator purely mechanical long stroke: 1m, 5m, 10m high loads: up to 160 kn and more options for high-cycle operation and harsh environments Our RollBeam series presents a broad

More information

2011 Cadillac CTS Coupe EGX Exhaust Tip & Rear Valance Mesh Accent Kit Part #: Complete E

2011 Cadillac CTS Coupe EGX Exhaust Tip & Rear Valance Mesh Accent Kit Part #: Complete E BILLET GRILLS IMPORTANT: PLEASE KEEP THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE! 2011 Cadillac CTS Coupe EGX Exhaust Tip & Rear Valance Mesh Accent Kit Part #: Complete 5122-1900-11E TOOLS REQUIRED Automotive

More information

Dry Contact Closure Interface

Dry Contact Closure Interface Dry Contact Closure Interface Overview LuXout Shades Dry Contact Closure Contact closure interfaces allows integration of the Automation systems throughout the house. The contact closure interface communicates

More information

New Plexo 3, all the space you need

New Plexo 3, all the space you need New Plexo 3, all the space you need IP 65 WEATHERPROOF ENCLOSURES No constraints on your wiring: plenty of space inside the box 2 PLEXO 3 - PLENTY OF SPACE FOR YOUR CONVENIENCE A wide range of enclosures

More information

Melody 1 Platform Lift

Melody 1 Platform Lift USER MANUAL Melody 1 Platform Lift Original instructions CONTENTS PAGE Introduction 4 Description 4 General Do s and Don ts 6 Controls 7 Operating the Lift 8 Emergency Procedures 9 Platform Gate Lock

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics

More information

Expansion Signal (XSIG) Card Installation Instructions

Expansion Signal (XSIG) Card Installation Instructions Expansion Signal (XSIG) Card Installation Instructions Introduction This publication describes the installation procedure for the Expansion Signal (XSIG) Card (4100-5116). This product is compatible with

More information

How to Implement xdrive Designs

How to Implement xdrive Designs How to Implement xdrive Designs The xdrive is a unique all-in-one LED driver and dimmer combination designed to fit into a standard recessed electrical box for use with constant-voltage dimmable lighting

More information

ACCESS SOLUTIONS NEW PRODUCTS BROCHURE.

ACCESS SOLUTIONS NEW PRODUCTS BROCHURE. ACCESS SOLUTIONS NEW PRODUCTS BROCHURE www.essentraaccesssolutions.com ESSENTIAL SOLUTIONS DELIVERED NEW PRODUCTS Locks Hinges Gaskets Handles Stainless Steel Products Electronic p3-6 p13 14 p17-18 p7-8

More information

Introducing Our Stud Contactor Series

Introducing Our Stud Contactor Series Stud or Series SW ors Stud Series 80 80 SW60 00 25 SW80 25 25 SW20 50 200 SW80 250 400 SW200 SU ors Stud Series 00 00 SU60 50 200 SU80 Introducing Our Stud or Series 250 350 SU280 Our stud contactor series

More information

Engineering data sheet

Engineering data sheet Chapter: Actuators Page: of Sheet No.: Ci ISB Solenoid Actuator Ci ISB Solenoid actuator Item numbers covered by his datasheet 00 Ci ISB Solenoid only 0 Ci ISB Solenoid & Manual General The Solenoid actuator

More information

Build your own THUNDERBIRD 2

Build your own THUNDERBIRD 2 PACK 04 PAGE 19 Pod 3 base 66 20 Pod 3 details and Firefly 69 21 Pod 3 laboratory and Firefly 72 22 Pod 3 floor details and Firefly 75 23 Pod 3 inspection walkways 78 24 Pod 3 right inner wall 81 25 Pod

More information

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1 INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: Dec., 2015 Version: 1.1 2 3 What s in the Box CONTENT 2 Screws & Anchors 2 Screwdriver 4 Diode Contents What s in the Box...2 Optional accessories...4

More information

Self-contained. BX-LED has a simple practical design suitable for general interior or exterior use.

Self-contained. BX-LED has a simple practical design suitable for general interior or exterior use. Self Contained BX-LED BX-LED has a simple practical design suitable for general interior or exterior use. Energy saving LED control technology Available in non-maintained or maintained operation Ingress

More information

TotalPac 3 Non interlock Preaction system Pneumatic release

TotalPac 3 Non interlock Preaction system Pneumatic release (Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a preaction system trim totally preassembled, pre-wired and factory tested. All electrical

More information

Fitting our replacement door lock springs Land Rover Discovery 1 Range Rover Classic FRONT DOORS

Fitting our replacement door lock springs Land Rover Discovery 1 Range Rover Classic FRONT DOORS Fitting our replacement door lock springs Land Rover Discovery 1 Range Rover Classic FRONT DOORS by x8rltd on May 23, 2014 Intro: Fitting our replacement door lock springs Land Rover Discovery 1 Range

More information

DMR 3005 WM ONE ZONE WIRELESS DIMMER RECEIVER

DMR 3005 WM ONE ZONE WIRELESS DIMMER RECEIVER E363518 DMR 3005 WM ONE ZONE WIRELESS DIMMER RECEIVER 20725 NE. 16 AVE. #A-33 MIAMI, FLORIDA 33179 Tel: (305) 652-2599 Fax: (305) 650-8812 www.lumiron.com Email: sales@lumiron.com 1 Benefits and Features

More information

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years

More information

Part Number: TTU-BGB14-DRL TTU-BGP14-DRL

Part Number: TTU-BGB14-DRL TTU-BGP14-DRL 11/15/16 TOYOTA TUNDRA 2014-17 Billet Grille w/led DRL Part Number: TTU-BGB14-DRL TTU-BGP14-DRL Kit Contents Item # Quantity Reqd. Description 1 2 LED DRL 2 1 Driver Box 3 1 Switch 4 1 User Card 5 2 Hardware

More information

212, 312 & 412 Vista Series Analog Panel Meter

212, 312 & 412 Vista Series Analog Panel Meter 212, 312 & 412 Vista Series Analog Panel Meter Application The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as

More information

APEM. LPI series. Tactile pushbutton switches with large actuator. Ø 35 mm actuator

APEM. LPI series. Tactile pushbutton switches with large actuator. Ø 35 mm actuator APEM LPI series Front or rear mounting Illuminated or non-illuminated Flexibility of marking Meeting the requirements of EN81-70 Ø 35 mm actuator Distinctive features and applications Common features

More information

QUICK START INSTALLATION GUIDE ANALOG - INTELLIGENT POWER CENTER (IPC)

QUICK START INSTALLATION GUIDE ANALOG - INTELLIGENT POWER CENTER (IPC) Intelligent LED Lighting Systems TM QUICK START INSTALLATION GUIDE ANALOG - INTELLIGENT POWER CENTER (IPC) LIGHTS & POWER: (Note all lights fixtures to be wired in series) 1) Identify dry, non-plenum location

More information

Emergency stops Award winning design

Emergency stops Award winning design Emergency stops Award winning design Emergency stops Choosing the right emergency stop device is vital in order to increase the safety for your personnel and equipment. ABB has a very wide range of emergency

More information

LED/Switch Modules Installation Instructions

LED/Switch Modules Installation Instructions LED/Switch Modules Installation Instructions Introduction This publication describes the installation procedure for the 4100-1288 LED/Switch Controller Card and the associated 4100-1275 to 1278, 4100-1280

More information

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers This brochure provides a comprehensive overview of the applications and associated functions available with Rotork Q actuators - comprising Q Standard and Q Pak actuators. The watertight Q Range actuators

More information

THERMOSTATIC CONCENTRIC DUAL CONTROL SHOWER VALVES Installation & aftercare instructions

THERMOSTATIC CONCENTRIC DUAL CONTROL SHOWER VALVES Installation & aftercare instructions THERMOSTATIC CONCENTRIC DUAL CONTROL SHOWER VALVES Installation & aftercare instructions Please retain for future reference EXPOSED CONCENTRIC VALVE SV2201 / SV4401 / SV5501 / SV6601 SV7701 / SV8801 /

More information

ROMpak Series. Keeping the World Flowing. Installation Manual. Valve Actuators

ROMpak Series. Keeping the World Flowing. Installation Manual. Valve Actuators ROMpak Series Installation Manual Valve Actuators Keeping the World Flowing Contents Section Page Introduction Health and safety X 3 Section Operating Title by hand Electrical Content operation 4 X5 Indication

More information

Milano AUTOMATIC FAUCET

Milano AUTOMATIC FAUCET Milano AUTOMATIC FAUCET with Surround Sensor Technology Installation & Maintenance IMPORTANT: PLEASE READ ENTIRE INSTRUCTION BOOKLET BEFORE YOU BEGIN INSTALLATION! Looks Clean - Is Clean. AutoFaucet Parts

More information

THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions

THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions Please retain for future reference DUAL INLINE CONCEALED VALVE SV2204 / SV4404 / SV5504 / SV6604 SV7704 / SV8804 / SV9904

More information

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS Instructions for: Digital Multimeter - 6 Function MOdel No: MM19.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions

More information

Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS Prestige Series Edge-Lit LED Sign AC, AC/DC and Self-Powered models Prestige Series Edge-Lit LED Sign WARNING: Risk of Shock. Disconnect Power before Installation. IMPORTANT SAFEGUARDS When using electrical

More information

Model WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise

Model WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise Data Sheet DS/WEP-EN Rev. C Model WEP Electro-pneumatic positioner WEP positioner A valve control without compromise Standard - ma input Single acting, force-balance operating principle Excellent dynamic

More information

Sondes USER GUIDE 90/NUG012ENG/07 ISSUE 7 03/2016

Sondes USER GUIDE 90/NUG012ENG/07 ISSUE 7 03/2016 Sondes USER GUIDE 90/NUG012ENG/07 ISSUE 7 03/2016 This user guide covers Radiodetection s range of sondes and associated accessories, including Flexrods and FlexiTraces, which can be used in tracing the

More information

(RNW) Power Resistor Chamber. Token Electronics Industry Co., Ltd. Version: January 13, Web:

(RNW) Power Resistor Chamber. Token Electronics Industry Co., Ltd. Version: January 13, Web: Version: January 13, 2017 (RNW) Power Resistor Chamber Token Electronics Industry Co., Ltd. Web: www.token.com.tw Email: rfq@token.com.tw Taiwan: No.137, Sec. 1, Zhongxing Rd., Wugu District, New Taipei

More information

Flush mounting enclosures. Pragma UP

Flush mounting enclosures. Pragma UP Flush mounting enclosures Presentation Flush mounting enclosures The appearance of this enclosure, its mechanical strength and its level of electrical safety make it a product fully suitable for residential

More information

BFF Motorised Trim Wheel - Set-up

BFF Motorised Trim Wheel - Set-up BFF Motorised Trim Wheel - Set-up Table of Contents Summary of Set-up Steps...1 BFF Motorised Trim Wheel - Setup Details...2 Final Set-Up For Direct Connection To FSUIPC/XPUIPC...5 Final Set-Up For Direct

More information

EC Type-Approval Certificate UK2853 Revision 4

EC Type-Approval Certificate UK2853 Revision 4 UK 2853 V(0)a EC Type-Approval Certificate UK2853 Revision 4 issued by: The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Non-automatic Weighing Instruments

More information

ov-lifting_bolts_divider - Updated Lifting Bolts

ov-lifting_bolts_divider - Updated Lifting Bolts ov-lifting_bolts_divider - Updated - 09-01-2017 Lifting Bolts Technical Information roduct information Lifting Bolts roduct marking Compliant with 2006/42/EC, and with individual date of manufacture and

More information

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use HM-08 OPERATING MANUAL Stepping motor and driver package High-efficiency AR Series DC power input Built-in Controller Type (RS-8 communication function) Driver Introduction Before use Only qualified personnel

More information