AC motors catalogue.

Size: px
Start display at page:

Download "AC motors catalogue."

Transcription

1 00 AC motors catalogue

2 :: geared motors :: legendary reliability :: totally customisable :: Product guide DC brushless (PBL) DC permanent magnet (PM) AC induction (SD) motors only Type Code Shaft Orientation Power (Watts)* Speed (rpm) Torque (Nm)** Power (Watts)* Speed (rpm) Torque (Nm)** Power (Watts)* Speed (rpm) Torque (Nm)** Max Max Min Max Min Max Min Max Min Max Min Max Min Max Min Max PBL/PM/SD Inline worm S M MB / MF L / LH LB / LF / LHB LS / LSH G / GH double worm SS 0 /Inline MM 0 /Inline MBM 0 /Inline inline double worm SIW Inline MIW Inline.. 0. LIW Inline inline spur SIS Inline MIS Inline 00 LIS Inline 0. worm spur SWS MWS LWS GWS planetary PG Inline PG Inline 0. PG Inline. 0. HP0 Inline * Continuous rated power ** Continuous output torque

3 Index General Information Maintenance Instructions Motors Induction Commutator Page Page Page Page Characteristics Connection/Wiring Diagrams Performance Dimensions Electro Magnetic Brakes and Wiring Diagrams Motor and Geared Units Optional Extras Blower Units Controllers & inverter Flange and Details and Final Shaft Positions Motor Rear End Mounting Details Tachometer / / / / for DC brushed permanent magnet and DC brushless motors and geared units, please refer to the appropriate dedicated catalogue Capacitors Gear Units Single Worm S type Page Performance Induction Dimensions Induction Performance Commutator Dimensions Commutator M Page 0 MB Page 0 L/LB/LH/LHB Page Double Worm SS type Page Performance Induction Dimensions Induction Performance Commutator 0 Dimensions Commutator MM MBM Page Page In Line Double Worm SIW type Page Performance Induction Dimensions Induction Performance Commutator Dimensions Commutator MIW LIW Page Page 0 In Line Multi Spur type Performance Induction Dimensions Induction Performance Commutator SIS Page Dimensions Commutator MIS Page / LIS Page Worm and Spur type SWS Page Performance Induction Dimensions Induction Performance Commutator Dimensions Commutator MWS Page LWS Page 0 0 GWS Page /

4 Terms and Conditions of Sale General Variation in price Quotations Acceptance Cancellation and variation Returns Terms Delivery Carriage Damage shortage and nondelivery Warranty Consequential damage Indemnity Drawings Tools Inspection and tests Legal construction Policy Contracts and orders are accepted subject to these conditions of sale. Unless expressly accepted in writing any qualification of these conditions contained in any document of the Buyer shall be deemed to be inapplicable. Unless otherwise stated all orders are accepted on condition any fluctuation in cost of materials and/or wages will entail a corresponding adjustment to the quoted price. We reserve the right to consider quotations invalid days after issue. All orders (which must be in writing) to be accompanied by sufficient information enabling us to proceed with the order forthwith, otherwise we shall be at liberty to amend the delivery and/or offer price. Once an order has been accepted by us it may not be cancelled or varied except with our consent, which at our discretion may be given only on terms which will indemnify us against any expense which shall include all our proper charges for work carried out and goods wholly or partly manufactured prior to the date of such cancellation or variation: If, owing to war, strikes, difficulty in obtaining materials or causes of any nature beyond our control we are unable to deliver any part of an order, we shall have the right (on giving notice in writing) to cancel the undelivered balance of the order and the customer shall not have any claim for or arising out of such inability, delay or cancellation. Goods supplied in accordance with customers orders cannot be accepted for return without our written consent; if approval is given a handling charge will be made. Returned goods must be consigned carriage paid. Subject to a minimum annual turnover our terms are strictly Nett Monthly Account, initial orders should be accompanied by a Bankers and two Trade References. Small value orders will be accepted on a cash with order basis or credit card details. The time given for delivery ex works is estimated only and not in any way guaranteed. Every endeavour will be made to meet the delivery given in good faith. We cannot however accept liability for failure to do so. When reduction in the scheduled rate of delivery is requested and agreed by us we reserve the right to make and shall be entitled to all additional charges incurred. Prices include delivery to U.K. mainland destinations, mode of transport at our discretion. When delivery is by a specific carrier at purchaser s request the carriage will be charged as an extra. We undertake to give separate postal notification on the day of despatch. Claims for nondelivery will not be entertained unless the carriers and ourselves are notified within days from despatch date or days in the case of postal or passenger train delivery services. Furthermore, we are unable to accept responsibility for damage, shortage or incorrect goods supplied, unless the carriers and ourselves are notified within days from receipt. Our products are guaranteed for a period of months from date of invoice against electrical breakdown or mechanical failure resulting from defective materials and/or workmanship providing the breakdown or failure is not due to misuse or operation under adverse conditions (including use with non Parvalux approved controllers). Any unit proving faulty and covered by the provisions of this guarantee must be returned to our works complete, carriage paid, for examination when it will be repaired or replaced at our option. Units that have been dismantled, carbon brushes, capacitors and flexible cables are excepted from this guarantee. Mutilation or removal of the nameplate will invalidate the guarantee. Every endeavour will be made to supply goods free from defects, we cannot accept any responsibility or entertain claims for consequential damages or expenses. The Buyer will indemnify us against damages, penalties, costs and expenses to which we may become liable as a result of work done in accordance with the Buyer s specification which involves an infringement of any letters, patents, or registered design. All drawings issued by us remain our property and must be returned on request. These must not be loaned, reproduced, copied or in any way altered wholly or in part without our written authority nor may information injurious to us be furnished from them. All tools, dies, moulds, jigs and fixtures, etc., will remain our property whether or not a charge is made towards their cost. Our products are carefully inspected and submitted to our standard tests at our works before despatch. If tests other than these are specified, or tests in the presence of you or your representative are required, these will be charged for. In the event of any delay on your part in attending such tests after days notice that we are ready, the tests will proceed in your absence and shall be deemed to have been made in your presence. Unless otherwise agreed in writing the contract shall in all respects be constructed and operate as an English contract and in conformity with English law. It is our policy to continuously develop and improve our products. We therefore reserve the right to modify or change our designs at our convenience and without prior notice. Whilst Parvalux takes all reasonably practicable steps to design and manufacture its products to comply with the requirements of the Health and Safety at Work Act, all products must be properly used and Purchasers are reminded that their obligations under the Act are to ensure that the installation and operation of such products at a place of work should be safe and without risk to health.

5

6 Some of your questions answered! Q A Q A Which motors/gearmotors are electrically reversible? All motors and gearmotors shown in this catalogue are reversible. (except shaded pole). Some require a full stop before reversing. Can continuous duty motors/gearmotors be used intermittently? All rated torques shown in this catalogue are for continuous operation. Continuous duty products can be used intermittently. Operation at loads higher than nameplate ratings is possible for short periods as long as there are rest periods for cooling. Loads must not exceed the mechanical rating for the gears (see page ) without consulting our sales engineers. The temperature of the motor should be monitored during testing to make sure it is not overheating. Q A Can more than one motor be operated from a single control? Operation of more than one motor from a single control is not normally recommended. However, when cost is a primary concern, a multiple motor/single control system with either permanent magnet motors and control, or phase motors and control may be successfully implemented. More than one permanent magnet motor may be operated with a single permanent magnet control as long as the sum of the motor currents does not exceed the rated output current of the controller. Comprehensive testing is recommended because this type of system may produce fluctuation or drifting speed output. More than one phase motor may be operated with a single phase control. Motor speeds should not fluctuate as long as the motors are not overloaded and the sum of the motor currents does not exceed the rated output current of the control. Q A Q A Q A Q A Q A Can single speed motors and gearmotors ever be operated as variable speed? Three phase and some Permanent Split Capacitor designs may be operated as variable speed with a frequency inverter. Commutator motors can be operated as variable speed using a thyristor controller. Is an adjustable speed system ever appropriate for a single speed application? Adjustable speed systems are sometimes appropriate for single speed applications. If the desired speed is not known or not offered in a single speed product, an adjustable speed system may be set to the desired speed. What is IP? The IP number is an international system for rating enclosures. An IP is for protection against dust and splashing liquids. What is meant by the term self locking? Self locking refers to the tendency of some gearing to resist movement when the gearmotor is at rest and the load is attempting to move. An example is a load on a conveyer belt trying to drive the system backwards. Which gearheads are self locking? Parallel shaft gearheads and right angle gearheads with low ratios are generally not considered to be Self locking. Right angle gearheads with ratios greater than are often considered to be Self locking. They will resist movement up to their torque rating. As the gearing nears the end of its useful life or if it is subjected to overload conditions, it may wear to the point where it is no longer Self locking. Self locking gearing is not a recommended method for preventing movement in applications where this movement may cause injury or damage. An external brake is recommended for those applications. (see pages, and ) Q A Q A Radial and Axial load parameters What is radial load? Radial load is a force pushing or pulling the side of the output shaft. It is shown as Fr above. Exceeding the allowable radial load for a motor or gearmotor will cause premature wear of output shaft bearings and gearing and could cause the shaft to break. Fr may be the result of a weight on the shaft, belt tension or torque transmitted through a belt, chain, gear, or certain flexible couplings. A permissible radial load, Fr, is shown for each motor and gearmotor. In calculating these values, the following assumptions were made: ) The radial load is in the worst case direction, i.e. pushing or pulling the shaft sideways. ) The motor or gearmotor is delivering rated torque. ) The radial load was applied at distance d from the hub or mounting surface. Higher radial loads may be applied closer in on the shaft. Lower radial loads are permitted further out on the shaft. Flexible couplings are often used to avoid radial load. Most flexible couplings are designed so that they do not transmit radial load, however this should be verified by the coupling manufacturer. What is axial load? Axial load is a force on the output shaft into or out of the motor or gearmotor. It is shown as Fa in the diagram above. Exceeding the allowable axial load for a motor or gearmotor will cause premature wear of output shaft bearings and gearing.

7 General Information and Maintenance Instructions Construction The frame comprises pressure diecastings accurately located together, alternatively on machined spigots of the hydraulically riveted stator packs, ensuring concentric air gap with correct bearing alignment. The armature laminations or diecast rotor are pressed onto a precision steel shaft. The armature after winding, impregnation and baking is then statically and dynamically balanced. All stators and armatures are wound with first class quality synthetic covered copper wire manufactured to B.S. ( IEC ) Class F and then impregnated and baked in our Automatic Plant, and accordingly can be considered to be tropically impregnated for all practical purposes. Motor Enclosures To IEC and EN 00:part and IEC and B.S. EN 00. Induction type motors: Our standard ventilated internal fan cooled frame conforms to IP 0. Commutator type motors SD ventilated internal fan cooled frame conforms to IP 0. SD, SD and PM, PM, PM, PM 0 Drip Proof enclosure, internal fan cooled, conforms to IP. Plain totally enclosed frame conforms to IP. TEFC frames with terminal box conforms to IP. PM, PM, PM, PM 0, PM, PM, PM, PM, PM also conforms to IP. Bearings Shielded ball bearings throughout, spring loaded for quiet running. Temperature parameters C to + C/ C. Brush Gear (Commutator motors). An adjustable rocker type for maximum brush life and good commutation with easily accessible brushes. To achieve maximum brush life a form factor on the supply voltage as near to as possible would be required. Testing To B.S. 000 Part II. ( IEC ). All our units are CE marked and comply to current regulations/directives at time of printing. Torque Ratings All gearbox torque figures have been reproduced to represent an accurate output figure. These figures may be affected by tolerances created during production techniques as well as application circumstances once the units have been installed. A margin of + or % should be taken into consideration on these figures during your selection of an appropriate unit. Temperature All motors are built with Class F insulation to B.S. ( IEC ) which allows a temperature rise of C based on an ambient of Type S M MB or MF L or LH LB or LFLHB SS MM MBM SIW MIW LIW SIS MIS LIS SWS MWS LWS GWS Ratios /: to 0: : to 0: : to 0: /: to 0: : to 0: : to : /: to 0: : to 0: : to : : to 0: 0: to 0: : to 0: 0: to 0: : to 0: 00: to 0: 0: to 00: : to 0: 00: to 0: 0: to : : to 0: 00: to 0: 0: to : All Ratios All Ratios All Ratios Worm/Pinion Spur Train : to : : to : : to.: : to : : to : : to : : to : : to : : to : 0: to : : to : : to : : to : : to : to : : to : : to 0: : to : : to : : to : : to : : to : : to : : to 0:.:.:.: : : :.:.:.:.:.:.: : : : : : : 0: COMPOSITE Approx Thermal Rating (W) = Final RPM Torque (Nm) (/n ) (η=gear efficiency). For intermittent duty the thermal rating for the gearbox is increased by multiplying the appropriate gearbox thermal rating by the factor X = 0 C. These figures are with the motor running in normal working conditions in free air and not in any form of enclosure. Under full load the heat of the motor casing will be such that it is NOT possible to handle for any length of time. Braking The problem of instantaneously stopping a motor or geared unit can be overcome by fitting an electromagnetic brake, details on pages, and. Gear units The motor is fitted with shielded spring loaded ball bearings absorbing worm thrust from the gear box. The output shaft with flats or keyways is carried in ball bearings pressed into gear wheels of composite or phosphor bronze with hardened and polished steel worms. and ball bearings packed with appropriate grade of grease. Worm and multispur gear units are fitted with case hardened steel spur gears with an oil bath lubrication. All units are suitable for running in any position. positions Alternative positions for the gearboxes can be arranged to suit customer s requirements (see page ) but unless specified, will be supplied in standard position as shown on the individual drawings. This also applies to the gearbox shaft extensions. Lubricants Single and double reduction worm gearboxes are charged with a suitable semifluid grease and sealed for life. Worm and multispur and inline spur gearboxes are filled with 0/0 multigrade oil and sealed for life, (in certain conditions semifluid grease may be used). Working temperature of lubricants: Grease C to C; Oil C to C. For units used in extreme temperature conditions i.e., below zero degrees centigrade please contact our sales department. Single and double worm reduction gearboxes Whilst worm gearing has lower efficiency than spur gearing it is true to say that generally the noise level of worm gear reduction is much lower and therefore, where noise is an important factor, this type of gearing should be considered. To prevent premature gear failure or excessive gear wear, the maximum gear loading and thermal rating of the particular gearbox must be taken into consideration otherwise there is a danger of stripping the gear wheel teeth or failure of the lubrication due to excessive gearbox temperature. If further information is required on this point please consult our sales engineers. The table below shows the recommended mechanical and thermal ratings for the various types of gearbox. Mechanical Rating (Nm) Thermal Rating (watts) *Radial Loading Axial Loading BRONZE COMPOSITE BRONZE LBS KG % Duty Cycle% *Based on midway point of standard shaft extension (Nm=.cm kp) (Nm=.lbs. ins) Maintenance Instructions All units are fitted with grease packed shielded ball bearings and sealed for life, this can vary depending on operating conditions, temperature, and duty cycle. We recommend replacing a noisy bearing, as regreasing is not possible. Prolonged storage can shorten the estimated life (in excess of 0,000 hours). In most cases dismantling of the motor or gearbox is straightforward. Carefully note the position of spring loaded washers, shims, etc. However the commutator type motors require a suitable extractor to remove the armature from the main frame. Commutator motors require more maintenance than induction type due to the accumulation of carbon dust in the brush gear area. This dust should be blown out periodically with a dry air supply observing Health & Safety. Directives regarding inhalation of carbon dust and only when the commutator surface is in a very blackened condition should it be lightly cleaned with flour paper or similar (note not emery paper). When replacing carbon brushes (which may have a life of some 000 hours depending on operating conditions) care should be taken to ensure these are a free fit in the brush holders. When dismantling, the brush gear should be marked to ensure it is replaced in the original position and the pigtails clear the motor casing. Magnetic brakes require little maintenance since wear of the bonded lining is automatically compensated for LBS KG

8 Connection Diagrams for Induction Motors Reverse Rotation Reverse Rotation Two Speed Phase High Speed Join and Insulate Join and Insulate L L L } L L L Low Speed Isolate and Insulate Leads Individually Two Speed Phase High Speed N L } Red Yellow N Red Yellow Capacitor L Red Yellow Red Yellow Black Blue Brown Low Speed Black Brown Blue L L Black N Blue Capacitor L Brown } } Reverse Rotation Isolate and Insulate Leads Individually Reverse Rotation Lead Capacitor Reverse Rotation Lead Capacitor Reverse Rotation Parvalux Electro Magnetic (Fail Safe) Stop Brakes (PP) for Induction Motors L Black Blue Brown L L L N L Capacitor Capacitor Black Capacitor Capacitor Black Red Red Capacitor Capacitor Red Red Capacitor L N L N L N L N A.C. Supply A.C. Supply A.C. Supply A.C. Supply A Phase Dual Voltage High Range Join and Insulate } *Capacitor start induction run units, capacitor must be connected in series with red lead as shown. A Red B Red C Red Low Range *Capacitor Start Induction Run Red Red L L L L L L Reverse Rotation Red Red B C A A B C A B C L L L L L L L N L N Reverse Rotation Reverse Rotation A.C. Supply A.C. Supply core cable 0cm long minimum. Note: Brakes cannot be fitted to T.E.F.C. units. For frequent stop/starts (more than per minute) please contact our sales engineers. B C Brake Size PPP Recommended Motor Frames SD, SD, SD and SD Weight g Brake Size PPP Recommended Motor Frames SD, SD and SD TYPE Input Power Input Volts Rated Torque P P P DIMENSIONS APPROVALS TYPE P P P VA (w) 0v A.C. 0. Nm VA (w) v A.C. 0. Nm VA (w) v D.C. 0. Nm A B C All dimensions in (mm) A: inc. adaptor plate C.S.A.CUS C.E. Rec. Class F ENCLOSURE IP Input Power Input Volts Rated Torque VA (w) 0v A.C. Nm VA (w) v A.C. Nm VA (w) v D.C. Nm DIMENSIONS A B C All dimensions in (mm) A: inc. adaptor plate These singledisc electro magnetic brakes are spring applied electrically released units which provide fail to safe operating characteristics, such that on interruption, or failure of power supply, the brake will engage and arrest the load. These brakes operate from single phase a.c. supply (not P or P) and incorporate a built in rectifier. This offers the brake a vibration free characteristic through a lower operating voltage spectrum. ElectroMagnetic Brake Wiring Diagrams 00V Three Phase Induction 0 Three Phase ( lead) Induction BRAKE L L L L L L Reverse Rotation B B B B Three Lead Capacitor Three Phase Dual Voltage A B C BRAKE A B C L L L L L L Reverse Rotation CAPACITOR Black Reverse Rotation Black BRAKE BRAKE L N L N A.C. Supply A.C. Supply HIGH RANGE A A B B C C BRAKE LOW RANGE B C A C A B BRAKE L L L L L L L L L L L L Reverse Rotation Reverse Rotation

9 Characteristics of Induction Motors CAPACITOR START CAPACITOR RUN MOTORS SPEED SPEED TORQUE FULL LOAD FULL LOAD Shown is a typical torque/speed characteristic for this type of motor, these units are only suitable for operating from a single phase AC supply and incorporate a permanently connected capacitor. The speed is fairly constant but it should be borne in mind that the starting torque is lower than the full load output usually in the order of % of full load. The motor however has the advantage of low starting current and is particularly suited for frequent reversing. Capacitor motors cause no radio or T.V. interference. (See below for capacitor details). SHADED POLE MOTORS Shown is a typical torque/speed characteristic for this motor. The speed is reasonably constant but between no load and full load the speed variation is greater than the permanent capacitor type. Starting torque is between 0%0% full load torque with the advantage of low starting current. It is important to note rotation is set and cannot be electrically reversed. This type of motor does not cause radio or T.V. interference. Induction & Ph TORQUE SPEED FULL LOAD CAPACITOR START INDUCTION RUN (CENTRIFUGAL SWITCH) Shown is a typical torque/speed characteristic for this type of motor, the speed is fairly constant over the no load to full load range. This unit incorporates an internal centrifugal switch which connects the starting winding, together with an electrolytic type capacitor, in the circuit for a few seconds. This winding and capacitor is only short time rated, the unit is not suitable for driving high inertia loads or frequent start/stops maximum recommended 0 per hour. The starting current is in the order of x full load current. This type of motor can be electrically reversed, but must not be reversed whilst running, the motor must be allowed to come to rest. TORQUE SPEED FULL LOAD THREE PHASE MOTORS Shown is a typical torque/speed characteristic for this type of motor and where a phase supply is available this motor should be the logical choice. The speed is constant and starting torque is good, in some cases up to 00% full load. It is possible to instantaneously reverse this type of motor whilst running. This type of motor does not cause radio or T.V. interference. TORQUE Capacitors The photograph shows the type of capacitor we are currently stocking. But other types may be supplied depending upon availability. Plastic case with part number, capacity, working voltage and connection diagram printed thereon. When two or more capacitors are necessary for operation then connect the capacitors in parallel. DATA Fixing M x mm long plastic stud and nut, lead length cm MFD Max Dimension 00 Working Voltage Part Number +% A Diameter B Length

10 Motor Types: SD SD SD SD SD SD or Phase Induction Motors Constant Speed Shaded Pole, Permanent Capacitor or Synchronous Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD SD SD SD with brake Voltage Range: /v 0/0v A.C. single phase, 0Hz. /0 A.C. three phase, 0Hz. Special voltages and frequencies quoted on request. Motor Type: Single phase with separate capacitor or three phase induction, suitable for reversing. Shaded pole (not reversible) anticlockwise rotation as standard. Starting Currents: Capacitor or three phase induction: approx. times full load. Shaded pole: approx times full load. Construction: Motors Shielded ball bearings spring loaded for quiet running. Single Reduction es: Fitted with ball bearings, alloy gearbox with composite gear wheel, grease lubricated for life and suitable for mounting in any position. InLine Double Reduction es: Fitted with ball bearings, alloy gearbox with composite gear wheel, grease or oil bath lubricated for life and suitable for mounting in any position. Spur Reduction es: Fitted with ball bearings, alloy gearbox with composite pinion wheel and multispur type hardened steel gears, oil bath lubricated for life. Suitable for mounting in any position. Connections: cm P.V.C. flexible (SD and SD terminal box). Insulation: Class F (maximum temperature rise C at a maximum ambient of 0 C). s: B.S. 000 part. (I.E.C. ). (CSA CUS if required). Optional Extras: Double ended motor spindles. Double ended gear shafts, (not available on inline units). Non standard shafts (stainless steel, keyways, flats, etc). Terminal box (not available on SD ). Totally enclosed frame half hour rating. Totally enclosed fan cooled frame (T.E.F.C.), continuous rating. (SD /SD only). Enclosure IP on request. Thermal overload protection. ElectroMagnetic Brake: Page. Tachogenerator: Page. Additional Extras for Geared Units: Non standard catalogue reductions maybe available on request. Bronze Gears: (Single and double reduction final gears). Flange Mounting Details: Page. Shaft Positions: Page. SD FULL LOAD 00 SD OUTPUT WATTS. STARTING TORQUE FULL LOAD 0% 0% CURRENT (AMPS) 0V 0. Permanent Capacitor 0 % % Single Phase Shaded Pole 0V INPUT WATTS 0 0 Single Phase Permanent Capacitor RATING TOTALLY ENCLOSED CONTINUOUS VENTILATED CONTINUOUS TOTALLY ENCLOSED / HR M.F.D. 0V 0V.. SD SD FULL LOAD (syn) OUTPUT WATTS 0 0 STARTING TORQUE FULL LOAD Three Phase CURRENT (AMPS) 0V % 0. 00% 0. 00% 0. Two Speed % 0. % 0. Synchronous V INPUT WATTS % FULL LOAD OUTPUT WATTS STARTING TORQUE CURRENT (AMPS) FULL LOAD 0V 0V % % Three Phase 0V V % % INPUT WATTS 0 CAPACITOR (M.F.D.) 0V. 0V. SD SD FULL LOAD 00 OUTPUT WATTS Single Phase Permanent Capacitor STARTING TORQUE CURRENT (AMPS) INPUT FULL WATTS LOAD 0V 0V % % Three Phase CAPACITOR (M.F.D.) 0V 0V SD SD FULL LOAD OUTPUT WATTS 0 STARTING TORQUE FULL LOAD Single Phase Permanent Capacitor CURRENT (AMPS) INPUT WATTS 0V 0V % % % Two Speed Permanent Capacitor CAPACITOR (M.F.D.) 0V. 0V. 00 % % 0V V % % Synchronous Permanent Capacitor 0 (syn) % 0. 0.

11 holes on.mm P.C.D. Can be tapped M mm deep. Dimensions in mm. Scale : Ø Ø Ø M spigot, see note. Optional terminal box tapped 0mm conduit or PG. on request. Standard entry position R.H.S. (Not available on SD). SD SD.0 Ø.. x.. SD SD. 0 Leads out here cm..0 Ø.. x.. Leads out here cm Induction & Ph Spigot M can be machined to./.mm dia. concentric with shaft 0.0mm T.I.R. Optional shaft at lead end,.mm dia. mm long. Approx. weight: SD. Kg SD. Kg. (T.E.F.C.) holes on.mm P.C.D. Can be tapped M mm deep. Dimensions in mm. Scale : Ø Ø Ø Ø Ø holes on.mm P.C.D. Can be tapped M mm deep. M spigot, see note.. (T.E.F.C.) SD SD.0 Ø. SD..0 Ø SD.. x... Leads out here cm Spigot M can be machined to./.mm dia. concentric with shaft 0.0mm T.I.R. Optional shaft at lead end see separate drawing for details. Not applicable to T.E.F.C. units.. 0. x.. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD.0 Kg SD.0 Kg. Leads out here cm. holes on.mm P.C.D. Can be tapped M mm deep. Tapped 0mm conduit or PG. on request. Dimensions in mm. Scale : Ø Ø Ø Ø M spigot, see note.. SD SD Tapped 0mm conduit or PG. on request..0 Ø. SD holes on.mm P.C.D. Can be tapped M mm deep...0 Ø SD.. x.... x.. Spigot M can be machined to./.mm dia. concentric with shaft 0.0mm T.I.R. Optional shaft at terminal box end see separate drawing for details. Approx. weight: SD. Kg SD. Kg Nondrive end extension (optional) Ø mm Ø.mm SD SD SD SD mm mm

12 Motor Types: SD SD SD or Phase Induction Motors Constant Speed Permanent Capacitor, Capacitor Start Induction Run, or Synchronous Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD SD with brake SD (T.E.F.C.) SD Voltage Range: /v 0/0v A.C. single phase, 0Hz. /0 A.C. three phase, 0Hz. Special voltages and frequencies quoted on request. Motor Type: Single phase with separate capacitor or three phase induction, suitable for reversing. (Capacitor start induction run SD and SD, both reversible but must be allowed to come to rest). Starting Currents: Capacitor or three phase induction: approx. times full load. Capacitor start induction run: times full load. Construction: Motors Shielded ball bearings spring loaded for quiet running. Single Reduction es: Fitted with ball bearings, alloy gearbox with composite gear, grease lubricated for life and suitable for mounting in any position. InLine Double Reduction es: Fitted with ball bearings, alloy gearbox with composite gears, oil bath lubricated for life and suitable for mounting in any position. Spur Reduction es: Fitted with ball bearings, alloy gearbox with composite pinion gear and multispur type hardened steel gears, oil bath lubricated for life. Suitable for mounting in any position. Optional Extras: Double ended motor spindles. Double ended gear shafts, (not available on inline gearboxes). Non standard shafts (stainless steel, keyways, flats, etc). Terminal box. Totally enclosed frame half hour rating. Totally enclosed fan cooled frame (T.E.F.C.), continuous rating. (Not SD ). Enclosure IP on request. Thermal overload protection. ElectroMagnetic Brake: Page. Tachogenerator: Page. Additional Extras for Geared Units: Non standard catalogue reductions available on request. Bronze Gears: (Single and double reduction final gears). Flange Mounting Details: Page. Shaft Positions: Page. Connections: cm P.V.C. flexible (SD and SD terminal box). Insulation: Class F (maximum temperature rise C at a maximum ambient of 0 C). s: B.S. 000 part. (I.E.C. ). (CSA CUS if required). Single Phase Three Phase SD SD FULL LOAD OUTPUT WATTS STARTING TORQUE FULL LOAD Permanent Capacitor CURRENT (AMPS) 0V 0V INPUT WATTS CAPACITOR (M.F.D.) 0V 0V SD SD FULL LOAD OUTPUT WATTS STARTING TORQUE FULL LOAD CURRENT (AMPS) 0V V INPUT WATTS 00 % % % % % % Capacitor Start Induction Run (SD only) Two Speed 00 %.. %.. 0 Two Speed Permanent Capacitor 0/0 M.F.D. 0 V R.M.S. Electrolytic 00 0 % Synchronous % (Syn) % Synchronous Permanent Capacitor 0 (Syn) % Three Phase SD FULL LOAD OUTPUT WATTS Single Phase Capacitor Start Induction Run ENCLOSURE STARTING TORQUE FULL LOAD CURRENT AMPS 0/0V INPUT WATTS CAPACITOR (M.F.D.) 0/0V SD FULL LOAD 00 OUTPUT WATTS 0 STARTING TORQUE FULL LOAD % % CURRENT (AMPS) 0V V INPUT WATTS 0 00 Ventilated (IP 0) %. 0 0/0 M.F.D. T.E.F.C. (IP ) %. 0V R.M.S. 00 Vent or T.E.F.C. %. ELECTROLYTIC

13 Dimensions in mm. Scale : SD. (T.E.F.C.) holes on.mm P.C.D. Can be tapped M mm deep. Ø Ø Ø Ø Ø holes on.mm P.C.D. Can be tapped M mm deep. M spigot see note.. Ø.00 x Leads out here cm Spigot M can be machined to./.mm dia. concentric with shaft 0.0mm T.I.R. Optional shaft at lead end, mm dia. mm long. Not applicable to T.E.F.C. units.. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD.0 Kg Induction & Ph Dimensions in mm. Scale : SD. Ø.00.. holes on.mm P.C.D. Can be tapped M mm deep. Electrolytic capacitor when necessary. Tapped 0mm conduit or PG. on request.. Ø Ø Ø Ø M spigot see note. holes on.mm P.C.D. Can be tapped M mm deep. x Spigot M can be machined to./.mm dia. concentric with shaft 0.0mm T.I.R. Optional shaft at terminal box end, mm dia. mm long. Approx. weight: SD.0 Kg. Dimensions in mm. Scale : Ø 0 Ø holes on.mm P.C.D. Ø Can be tapped M mm deep. Ø Ø holes on.mm P.C.D. Can be tapped M mm deep. M spigot see note. SD (T.E.F.C.). Ø.00 Electrolytic capacitor when necessary. x Terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. Spigot M can be machined to./.mm dia. concentric with shaft 0.0mm T.I.R. Approx. weight: SD T.E.F.C..0 Kg Dimensions in mm. Scale : SD. Ø.00.. holes on.mm P.C.D. Can be tapped M mm deep. Electrolytic capacitor when necessary. Tapped 0mm conduit or PG. on request.. Ø Ø Ø Ø M spigot see note. holes on.mm P.C.D. Can be tapped M mm deep. x. 0.. Spigot M can be machined to./.mm dia. concentric with shaft 0.0mm T.I.R. Optional shaft at terminal box end, mm dia. mm long. Approx. weight: SD.0 Kg

14 Type: S Speed Range: 0 r.p.m. Single Reduction Worm Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD S SD S SD S (T.E.F.C.) SD S Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) r.p.m. SD S ( Phase Only) Shaded Pole (T.E.) Shaded Pole/Capacitor. watts watts SD S or Phase watts SD S SD S or Phase watts SD S SD S or Phase watts COMPOSITE COMPOSITE COMPOSITE COMPOSITE BRONZE COMPOSITE BRONZE : : 0: : : : 0: : : : : /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: r.p.m. SD S or Phase watts SDSSDS or Phase 0 watts SD S SD S Phase Phase watts watts 00 r.p.m. SD S SD S Phase Phase watts watts COMPOSITE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE COMPOSITE : : 0: : : : 0: : : : : /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: : : 0: : : : 0: : : : : /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /:

15 mm dia. h. Flat mm mm long. Dimensions in mm. Scale : Ø Optional terminal box tapped 0mm conduit or PG. on request. Standard entry position R.H.S. (Not available on SD). SD S SD S x... SD SD. 0 Leads out here cm.. x... Leads out here cm Induction & Ph Optional shaft at motor speed (lead end only).mm dia. mm long. Approx. weight: SD S. Kg SD S. Kg Dimensions in mm. Scale : Ø SD S SD S 0 (T.E.F.C.) mm dia. h. Flat mm mm long. Ø (T.E.F.C.) 0 SD.. SD. x.... Leads out here cm.. x... Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Optional shaft at motor speed (lead end only) see separate motor drawing for details (Page ). Not applicable to T.E.F.C. units.. Leads out here cm Approx. weight: SD S. Kg SD S. Kg Dimensions in mm. Scale : SD S SD S Tapped 0mm conduit or PG. on request. mm dia. h. Flat mm mm long. Ø 0 Tapped 0mm conduit or PG. on request. SD.. SD. x x.... Optional shaft at motor speed (terminal box end only) see separate motor drawing for details (Page ). Approx. weight: SD S. Kg SD S.00 Kg

16 Type: M Speed Range: 0 r.p.m. Single Reduction Worm Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD M SD M (T.E.F.C.) SD M SD M with brake Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages, and for full details. Hollow shaft available on request. Maximum internal diameter mm. ( Nm =. lbs. ins.) ( Nm =. cmkp) r.p.m. SDMSDM or Phase watts SD M SD M or Phase watts SD M SD M Phase Phase watts watts SD M Phase (Capacitor start induction run) watts COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE 0 0 : : 0: : : : 0: : : : : /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: r.p.m : : 0: : : : 0: : : : : /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SD M M or Phase 0 watts COMPOSITE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE COMPOSITE COMPOSITE BRONZE COMPOSITE BRONZE SD M M Phase Phase watts watts SD M M Phase Phase watts watts r.p.m. 0 0 : : 0: : : : 0: : : : : /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SDMM Phase Phase watts watts SD M M Phase Phase watts 0 watts

17 Dimensions in mm. Scale : mm dia. h.. (T.E.F.C.) Keyway mm mm long. Alternative, Ø hollow shaft mm Ø inside diameter. (T.E.F.C.) SD M SD M. x. 0. SD. Leads out here cm x. 0. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD M. Kg Optional shaft at motor speed (lead end only) see separate motor drawing for details (Page ). Not applicable to T.E.F.C. units. SD M. Kg SD. Leads out here cm Induction & Ph 0 mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. Dimensions in mm. Scale :. Ø SD M SD M. x. 0. SD. Tapped 0mm conduit or PG. on request..... x. 0. SD. Tapped 0mm conduit or PG. on request. Optional shaft at motor speed (terminal box end only) see separate motor drawing for details (Page ). Approx. weight: SD M. Kg SD M. Kg (T.E.F.C.) Dimensions in mm. Scale : mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter.. Ø Ø SD M.. x... Leads out here cm Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Optional shaft at motor speed (lead end only) mm dia. mm long. Not applicable to T.E.F.C. units. Approx. weight: SD M. Kg Dimensions in mm. Scale : mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. Electrolytic capacitor when necessary.. Ø SD M. Tapped 0mm conduit or PG. on request... x... Optional shaft at motor speed (terminal box end only) mm dia. mm long. Approx. weight: SD M. Kg

18 Type: MB Speed Range: 0 r.p.m. Single Reduction Worm Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD MB SD MB (T.E.F.C.) SD MF SD MB with brake Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages, and for full details. Hollow shaft available on request. Maximum internal diameter mm. ( Nm =. lbs. ins.) ( Nm =. cmkp) r.p.m. SD MB SD MB or Phase watts SD MB SD MB or Phase watts SD MB SD MB Phase Phase watts watts SD MB Phase (Capacitor start induction run) watts COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE 0 0 : : 0: : : : 0: : : : : /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: r.p.m : : 0: : : : 0: : : : : /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SD MB MB or Phase 0 watts COMPOSITE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE COMPOSITE COMPOSITE BRONZE COMPOSITE BRONZE SD MB MB Phase Phase watts watts SD MB MB Phase Phase watts watts r.p.m. 0 0 : : 0: : : : 0: : : : : /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SD MB MB Phase Phase watts watts SD MB MB Phase Phase watts 0 watts

19 0. Dimensions in mm. Scale : NB: Unit drawn is SD MB SD (T.E.F.C.) = SD MB (T.E.F.C.) = Ø SD MB = 0 Ø SD MB = 0 SD MB SD MB. x. Leads out here cm Optional shaft at motor speed (lead end only) see separate motor drawing for details (Page ). Not applicable to T.E.F.C. units. 0. mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter... Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD MB.0 Kg SD MB.0 Kg Induction & Ph Dimensions in mm. Scale : NB: Unit drawn is SD MB SD MB = 0 SD MB = Ø SD MB SD MB 0. Tapped 0mm conduit or PG. on request x. mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter.. Optional shaft at motor speed (terminal box end only) see separate motor drawing for details (Page ). Approx. weight: SD MB. Kg SD MB. Kg Dimensions in mm. Scale : SD MB (T.E.F.C.) Ø (T.E.F.C.) Ø 0.. x. Leads out here cm 0. mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter... Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Optional shaft at motor speed (lead end only) mm dia. mm long. Not applicable to T.E.F.C. units. Approx. weight: SD MB. Kg Dimensions in mm. Scale : SD MB Ø 0. Electrolytic capacitor when necessary.. Tapped 0mm conduit or PG. on request x. mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter.. Optional shaft at motor speed (terminal box end only) mm dia. mm long. Approx. weight: SD MB. Kg

20 Type: L/LB/LH/LHB Speed Range: r.p.m. Single Reduction Worm Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD L SD LB (T.E.F.C.) SD LF Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. LH/LHB, for hollow shaft details see page. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD L/LB/LH/LHB SD L/LB/LH/LHB SD L/LB/LH/LHB Phase Phase r.p.m. Capacitor Start Induction Run watts Permanent Capacitor watts watts Phase Capacitor Start Induction Run watts watts Ventilated T.E.F.C. SD L/LB/LH/LHB Phase COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE watts BRONZE 0: 0: 0: : 0 /: /: /: /: /: /: r.p.m. SD L/LB/LH/LHB SD L/LB/LH/LHB SD L/LB/LH/LHB Phase Phase Capacitor Start Induction Run watts Permanent Capacitor watts watts SD L/LB/LH/LHB Phase Phase Capacitor Start Induction Run watts COMPOSITE COMPOSITE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE 0 watts BRONZE 0 0: 0: 0: : 0 /: /: /: /: /: /:

21 mm dia. h. Keyway mm mm long. Alternative, LH gearbox with mm inside dia. hollow shaft (mm external dia.). Also available with solid shaft up to mm dia. Length as required. (T.E.F.C.) Dimensions in mm. Scale :. Ø Electrolytic capacitor when necessary (SD ). (T.E.F.C.) SD L SD L SD Ø. x. Optional terminal box Leads out tapped 0mm conduit or... here cm PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Optional shaft at motor speed (lead end only) mm dia. mm long. Not applicable to T.E.F.C. units. SD x. Ø Approx. weight: SD L. Kg SD L (T.E.F.C.).0 Kg Induction & Ph mm dia. h. Keyway mm mm long. Alternative, LH gearbox with mm inside dia. hollow shaft (mm external dia.). Also available with solid shaft up to mm dia. Length as required. (T.E.F.C.) Dimensions in mm. Scale : Electrolytic capacitor when necessary (SD ). Ø (T.E.F.C.) SD LB SD LB SD Ø SD. Ø 0 x. Leads out here cm Optional shaft at motor speed (lead end only) mm dia. mm long. Not applicable to T.E.F.C. units x. 0 Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD LB. Kg SD LB (T.E.F.C.). Kg mm dia. h. Keyway mm mm long. Alternative, LH gearbox with mm inside dia. hollow shaft (mm external dia.). Also available with solid shaft up to mm dia. Length as required. Dimensions in mm. Scale :. Ø Electrolytic capacitor when necessary. SD L SD L SD. SD.. x... Tapped 0mm conduit or PG. on request. Optional shaft at motor speed (terminal box end only) mm dia. mm long. x.. Tapped 0mm conduit or PG. on request. Approx. weight: SD L. Kg SD L. Kg Dimensions in mm. Scale : NB: Unit drawn is SD LB SD LB = SD LB = Ø SD LB SD LB Electrolytic capacitor when necessary.. Tapped 0mm conduit or PG. on request x. Optional shaft at motor speed (terminal box end only) mm dia. mm long. mm dia. h. Keyway mm mm long. Alternative, LHB gearbox with mm inside dia. hollow shaft (mm external dia.). Also available with solid shaft up to mm dia. Length as required. 0 0 Approx. weight: SD LB. Kg SD LB. Kg

22 Type: SS Speed Range: 0. 0 r.p.m. Double Reduction Worm Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD SS SD SS (T.E.F.C.) SD SS SD SS with brake Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp ) SD SS ( Phase Only) Shaded Pole Shaded Pole Capacitor Totally Enclosed Ventilated r.p.m.. watts watts watts r.p.m : : : 0: : : : : : : 0: 0: : : : : : : : : : : : : : 00: : : 0: : : : : : : 0: 0: : : : : : : : : : : : : : : : : COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE SD SS SD SS SD SS SD SS SD SS or Phase or Phase or Phase watts COMPOSITE COMPOSITE COMPOSITE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE SD SS SD SS SD SS SD SS SD SS or Phase watts or Phase 0 watts Phase watts Phase watts watts 00 r.p.m. 00: : : 0: : : : : : : 0: 0: : : : : : : : : : : : : : watts BRONZE SD SS SD SS Phase Phase watts watts BRONZE

23 mm dia. h. Flat mm mm long. Dimensions in mm. Scale : Ø. Optional terminal box tapped 0mm conduit or PG. on request. Standard entry position R.H.S. (Not available on SD ). SD SS SD SS. SD SD... x.. 0 Leads out here cm x. Leads out here cm Induction & Ph Optional shaft at motor speed (lead end only).mm dia. mm long. Approx. weight: SD SS. Kg SD SS. Kg Dimensions in mm. Scale : SD SS SD SS (T.E.F.C.) 0 mm dia. h. Flat mm mm long.. (T.E.F.C.) SD Ø Ø. SD Ø Ø.... x.. Leads out here cm. 0. x.. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Leads out here cm Optional shaft at motor speed (lead end only) see separate motor drawing for details (Page ). Not applicable to T.E.F.C. Approx. weight: SD SS. Kg SD SS. Kg Dimensions in mm. Scale : SD SS SD SS 0 Tapped 0mm conduit or PG. on request. mm dia. h. Flat mm mm long.. Tapped 0mm conduit or PG. on request. SD Ø. SD Ø.... x.... x.. Optional shaft at motor speed (terminal box end only) see separate motor drawing for details (Page ). Approx. weight: SD SS. Kg SD SS. Kg

24 Type: MM Speed Range: 0. r.p.m. Double Reduction Worm Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD MM SD MM (T.E.F.C.) SD MM with brake Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages, and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD MM ( Phase Only) SD MM SD MM SD MM SD MM Shaded Pole (Vent) Permanent Capacitor or Phase or Phase r.p.m : : : 0: : : 0: : : : 0: 0: : : : : : : : : : : : : 0: : : : COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE watts watts watts.... watts BRONZE.... r.p.m : : : 0: : : 0: : : : 0: 0: : : : : : : : : : : : : 0: : : : SD MM Phase Capacitor Start Induction Run watts SD MM SD MM Phase Phase Capacitor watts COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE watts BRONZE

25 mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. Dimensions in mm. Scale : Ø. SD MM (T.E.F.C.) mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. Dimensions in mm. Scale :. Ø Ø (T.E.F.C.) mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. SD MM SD MM. SD. SD.. x... Leads out here cm. Optional shaft at motor speed (lead end only) see separate motor drawing for details (Page ). Not applicable to T.E.F.C. units.. x... Leads out here cm Approx. weight: SD MM. Kg SD MM. Kg mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. Dimensions in mm. Scale :. Ø mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. SD MM SD MM. SD. SD. x... Optional shaft at motor speed (terminal box end only) see separate motor drawing for details (Page ).... x... Approx. weight: SD MM. Kg SD MM.00 Kg Tapped 0mm conduit or PG. on request. (T.E.F.C.) Dimensions in mm. Scale :. SD MM Ø Ø.. x. Leads out.. here cm Optional shaft at motor speed (lead end only) mm dia. mm long. Not applicable to T.E.F.C. units.. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD MM. Kg mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. Dimensions in mm. Scale : Tapped 0mm conduit or PG. on request. Electrolytic capacitor when necessary.. SD MM. Ø..... x.. 0 Leads out here cm Optional shaft at motor speed (lead end only).mm dia. mm long... Approx. weight: SD MM. Kg Induction & Ph Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Tapped 0mm conduit or PG. on request. mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. x... Optional shaft at motor speed (terminal box end only) mm dia. mm long. Approx. weight: SD MM. Kg

26 Type: MBM Speed Range: 0. r.p.m. Double Reduction Worm Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD MBM SD MBM Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages, and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) r.p.m : : : 0: : : 0: : : : 0: 0: : : : : : : : : : : : : 0: : : : SD MBM ( Phase Only) SD MBM SD MBM SD MBM SD MBM Shaded Pole (Vent) Permanent Capacitor or Phase or Phase watts watts watts COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE watts BRONZE.... r.p.m : : : 0: : : 0: : : : 0: 0: : : : : : : : : : : : : 0: : : : SD MBM Phase Capacitor Start Induction Run watts SD MBM SD MBM Phase Phase Capacitor watts COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE watts BRONZE

27 SD MBM = SD MBM = Dimensions in mm. Scale : mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. Ø. SD MBM SD MBM. x. Optional shaft at motor speed (lead end only).mm dia. mm long. SD MBM (T.E.F.C.) = SD MBM (TE.F.C.) = SD MBM = SD MBM = Leads out here cm Dimensions in mm. Scale : NB: Unit drawn is SD MBM mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. 0.. Ø Ø. 0. Approx. weight: SD MBM. Kg SD MBM. Kg SD MBM SD MBM. Induction & Ph. x. Leads out here cm Optional shaft at motor speed (lead end only) see separate motor drawing for details (Page ). Not applicable to T.E.F.C. units. 0.. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD MBM. Kg SD MBM. Kg SD MBM = SD MBM = Dimensions in mm. Scale : NB: Unit drawn is SD MBM mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. Ø. SD MBM SD MBM 0. Tapped 0mm conduit or PG. on request.. x.. Optional shaft at motor speed (terminal box end only) see separate motor drawing for details (Page ).. Approx. weight: SD MBM. Kg SD MBM.0 Kg (T.E.F.C) Dimensions in mm. Scale :. SD MBM mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter.. Ø Ø. x. Leads out here cm Optional shaft at motor speed (lead end only) mm dia. mm long. Not applicable to T.E.F.C. units. 0.. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD MBM. Kg Dimensions in mm. Scale : Electrolytic capacitor when necessary.. SD MBM. Ø Tapped 0mm conduit or PG. on request.. mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. 0. x.. Optional shaft at motor speed (terminal box end only) mm dia. mm long.. Approx. weight:. Kg

28 Type: SIW Speed Range: r.p.m. In Line Double Reduction Worm Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) SD SIW SD SIW SD SIW SD SIW Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. Minimum speed of 0, r.p.m. obtainable on request, using 00 r.p.m. motor. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD SIW SD SIW SD SIW Phase or Phase SD SIW Capacitor or Phase r.p.m. watts watts 0 0 INT : : /: /: /: /: /: /: /: /: /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: watts COMPOSITE COMPOSITE COMPOSITE BRONZE r.p.m. 0 INT : : /: /: /: /: /: /: /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SD SIW SD SIW SD SIW Phase or Phase SD SIW Capacitor or Phase 0 watts watts 0 watts COMPOSITE COMPOSITE BRONZE COMPOSITE BRONZE

29 Dimensions in mm. Scale : SD SIW mm dia. h. Flat mm mm long. holes on.mm P.C.D. Can be tapped M mm deep... Optional shaft at motor speed (lead end only).mm dia. mm long. Ø holes can be tapped M mm deep. Ø 0. Ø Leads out here cm. Approx. weight: SD SIW. Kg Induction & Ph Dimensions in mm. Scale : SD SIW mm dia. h. Flat mm mm long. Optional terminal box tapped 0mm conduit or PG. on request. Standard entry position. R.H.S... Ø Ø 0. Ø holes on.mm P.C.D. Can be tapped M mm holes can be tapped M mm deep. Leads out here cm. Optional shaft at motor speed (lead end only).mm dia. mm long. Approx. weight: SD SIW. Kg Dimensions in mm. Scale : SD SIW mm dia. h. Flat mm mm long.. (T.E.F.C.) holes on.mm P.C.D. Can be tapped M mm deep. 0 Ø Ø 0. Ø Ø Leads out here cm. holes can be tapped M mm deep. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Optional shaft at motor speed (lead end only) see separate motor drawing for details (Page ). Not applicable to T.E.F.C. units. Approx. weight: SD SIW:. Kg Dimensions in mm. Scale : SD SIW mm dia. h. Flat mm mm long.. holes on.mm P.C.D. Can be tapped M mm deep. Tapped 0mm conduit or PG. on request. Ø 0. Ø Ø. holes can be tapped M mm deep. Optional shaft at motor speed (terminal box end only) see separate motor drawing for details (Page ). Approx. weight: SD SIW. Kg

30 Type: MIW Speed Range: r.p.m. In Line Double Reduction Worm Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD MIW SD MIW SD MIW (T.E.F.C.) Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. Minimum speed 0. r.p.m. obtainable using 00 r.p.m. motor (SD ). ( Nm =. lbs. ins.) ( Nm =. cmkp) SD MIW Phase Capacitor r.p.m. watts 0 INT : : /: /: /: /: /: /: /: /: /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SD MIW or Phase watts SD MIW SD MIW or Phase watts COMPOSITE COMPOSITE COMPOSITE BRONZE COMPOSITE SD MIW SD MIW or Phase watts BRONZE r.p.m. 0 INT : : /: /: /: /: /: /: /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SD MIW Phase 0 watts SD MIW or Phase watts SD MIW SD MIW or Phase 0 watts SD MIW SD MIW Phase Phase watts watts COMPOSITE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE

31 Dimensions in mm. Scale : NB: Unit drawn is SD MIW SD MIW SD MIW Optional terminal box tapped 0mm conduit or PG. on request. Standard entry position R.H.S. (Not available on SD ). SD MIW = SD MIW =.. mm dia. h. Keyway mm mm long... holes tapped M mm deep. holes on.mm P.C.D. Can be tapped M mm deep. Leads out here cm Ø. Ø. Ø.. 0 Motor C L Induction & Ph Optional shaft at motor speed (lead end only).mm dia. mm long. Approx. weight: SD MIW. Kg SD MIW. Kg Dimensions in mm. Scale : NB: Unit drawn is SD MIW SD MIW SD MIW.. SD MIW (T.E.F.C.) = SD MIW (T.E.F.C.) = SD MIW = 0 SD MIW = Ø Ø. 0 holes on.mm P.C.D. Can be tapped M mm deep... SD MIW = 0 SD MIW = Ø.. Ø. Ø.. Ø. Ø. Motor C L mm dia. h. Keyway mm mm long.. holes tapped M mm deep. Leads out here cm Optional shaft at motor speed (lead end only) see separate motor drawing for details (Page ). Not applicable to T.E.F.C. units.. 0 Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD MIW. Kg SD MIW. Kg Dimensions in mm. Scale : NB: Unit drawn is SD MIW SD MIW SD MIW Tapped 0mm conduit or PG. on request. holes on.mm P.C.D. Can be tapped M mm deep. Motor C L mm dia. h. Keyway mm mm long.. holes tapped M mm deep. Optional shaft at motor speed (terminal box end only) see separate motor drawing for details (Page ).. 0 Approx. weight: SD MIW.0 Kg SD MIW. Kg

32 Type: LIW Speed Range:. r.p.m. In Line Double Reduction Worm Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD LIW SD LIW with brake SD LIW SD LIW (T.E.F.C.) Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages, and for full details. Minimum speed of 0. r.p.m. obtainable using 00 r.p.m. motor (SD ). ( Nm =. lbs. ins.) ( Nm =. cmkp) r.p.m GEAR INT 0: : : : 0 /: /: /: /: /: /: /: /: /: /: /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: : : : : : SD LIW SD LIW SD LIW SD LIW SD LIW SD LIW or Phase or Phase Phase Phase COMPOSITE watts BRONZE COMPOSITE. watts BRONZE COMPOSITE watts BRONZE COMPOSITE watts BRONZE 00 r.p.m... 0 GEAR INT 0: : : : 0 /: /: /: /: /: /: /: /: /: /: /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: : : : : : SD LIW SD LIW or Phase 0 watts SD LIW SD LIW Phase Phase watts watts SD LIW SD LIW Phase Phase watts COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE watts BRONZE

33 mm dia. h. Keyway mm mm long. 0 holes tapped M mm deep... 0 SD LIW (T.E.F.C.) = SD LIW (T.E.F.C.) = SD LIW = SD LIW = Dimensions in mm. Scale : NB: Unit drawn is SD LIW Optional shaft at motor speed (lead end only) see separate motor drawing for details. (Page ). Not applicable to T.E.F.C. units. Ø Ø Leads out here cm holes on.mm P.C.D. Can be tapped M mm deep. Ø. Ø Motor C L SD LIW SD LIW Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD LIW. Kg SD LIW.0 Kg Induction & Ph mm dia. h. Keyway mm mm long... SD LIW = SD LIW = Dimensions in mm. Scale : NB: Unit drawn is SD LIW holes on.mm P.C.D. Can be tapped M mm deep. Tapped 0mm conduit or PG. on request.. SD LIW SD LIW 0 Ø Ø. Ø.. holes tapped M mm deep. 0 Optional shaft at motor speed (terminal box end only) see separate motor drawing for details. (Page ) Approx. weight: SD LIW. Kg SD LIW.0 Kg mm dia. h. Keyway mm mm long... (T.E.F.C.) 0 Dimensions in mm. Scale : holes on.mm P.C.D. Can be tapped M mm deep.. SD LIW 0 holes tapped M mm deep. 0 Optional shaft at motor speed (lead end only) mm dia. m long. Not applicable to T.E.F.C. units. Ø Ø Leads out here cm Ø. Ø.. 0. Optional terminal box tapped 0mm conduit or PG. on request. Shown. standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD LIW. Kg. Motor C L mm dia. h. Keyway mm mm long... Electrolytic capacitor when necessary. Dimensions in mm. Scale : holes on.mm P.C.D. Can be tapped M mm deep. Tapped 0mm conduit or PG. on request.. SD LIW 0 Ø Ø. Ø.. Motor C L. Motor CL holes tapped M mm deep. 0 Optional shaft at motor speed (terminal box end only) mm dia. mm long Approx. weight: SD LIW. Kg

34 Type: SIS Speed Range: r.p.m. In Line Reduction MultiSpur Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD SISF SD SIS with brake SD SIS (T.E.F.C.) SD SIS Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) r.p.m. SD SIS Phase SD SIS or Phase SD SIS SD SIS or Phase watts watts watts. 0 : : : : : : : : : r.p.m. SD SIS SD SIS SD SIS SD SIS Phase or Phase or Phase 0 watts watts 0 watts.. : : : : : : : : : r.p.m. SD SIS SD SIS Phase Phase watts watts... : : : : : : : : :

35 Optional terminal box tapped 0mm conduit or PG. on request. Standard entry position R.H.S. (Not available on SD ). Dimensions in mm. Scale : NB: Unit drawn is SD SIS Ø SD SIS SD SIS SD SIS = SD SIS = Ø Ø Optional mounting flange. (See below).. mm dia. h. Flat mm mm long... Optional shaft at motor speed (lead end only).mm dia. mm long. holes tapped M mm deep. Leads out here cm 0 0 holes on.mm P.C.D. Can be tapped M mm deep. Approx. weight: SD SIS. Kg SD SIS.0 Kg Induction & Ph Dimensions in mm. Scale : Ø Ø SD SIS (T.E.F.C.) Optional mounting flange. (See below).. Ø Ø 0 mm dia. h. Flat mm mm long. 0.. holes tapped M mm deep. Leads out here cm 0 Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). holes on.mm P.C.D. Can be tapped M mm deep. Optional shaft at motor speed (lead end only) see separate motor drawing for detail (Page ). Not applicable to T.E.F.C. units. Approx. weight: SD SIS. Kg Dimensions in mm. Scale : Ø Ø SD SIS Optional mounting flange. (See below).. Tapped 0mm conduit or PG. on request. Ø mm dia. h. Flat mm mm long. 0.. holes tapped M mm deep. 0 holes on.mm P.C.D. Can be tapped M mm deep. Optional shaft at motor speed (terminal box end only) see separate motor drawing for details (Page ). Approx. weight: SD SIS. Kg.. Dimensions in mm. Scale : Ø Ø Optional Plastic Mounting Flange equally spaced holes on.mm P.C.D. cored.mm dia. SIS standard shaft extension Ø

36 Type: MIS Speed Range: r.p.m. In Line Reduction MultiSpur Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD MIS Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages, and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD MIS SD MIS or Phase r.p.m. watts 0 PINION SPUR SD MIS SD MIS or Phase watts SD MIS / SD MIS Phase Phase watts watts 00 r.p.m. 0 PINION SPUR SD MIS SD MIS or Phase 0 watts SD MIS SD MIS Phase Phase watts watts SD MIS / SD MIS Phase Phase watts watts mm dia. h. keyway mm mm long. SD (T.E.F.C.) = SD (T.E.F.C.) = SD MWS = SD MWS = Dimensions in mm. Scale : NB: Unit drawn is SD MIS. 0 SD MIS SD MIS.. 0 Motor C L Ø Ø Ø Leads out here cm. 0 holes on mm P.C.D. Can be tapped M mm deep. holes tapped M mm deep. Optional shaft at motor speed (lead end only) see separate motor drawing for details (Page ). Not applicable to T.E.F.C. units. Ø 0 = = = = Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD MIS. Kg SD MIS. Kg

37 Ø mm dia. h. Keyway mm mm long. SD MWS = SD MWS = Dimensions in mm. Scale : NB: Unit drawn is SD MIS Tapped 0mm conduit or PG. on request.. SD MIS SD MIS. 0 Ø holes on mm P.C.D. Can be tapped M mm deep. Ø 0. Motor C L Induction & Ph. 0 holes tapped M mm deep. = = = = Optional shaft at motor speed (terminal box end only) see separate motor drawing for details (Page ). Approx. weight: SD MIS. Kg SD MIS. Kg Dimensions in mm. Scale : SD MIS mm dia. h. Keyway mm mm long. SD MIS (T.E.F.C.) = SD MIS =.. 0 Dimensions in mm. Scale :. SD MIS.. Ø Ø.. Ø Ø Ø Leads out here cm. 0 holes on mm P.C.D. Can be tapped M mm deep. holes tapped M mm deep. Ø 0 = = = = Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Optional shaft at motor speed (lead end only) mm dia. mm long. Not applicable to T.E.F.C. units. Approx. weight: SD MIS. Kg mm dia. h. Keyway mm mm long. Electrolytic capacitor when necessary. Motor C L 0 Motor C L Tapped 0mm conduit or PG. on request. holes on mm P.C.D. Can be tapped M mm deep. Ø 0. 0 holes tapped M mm deep. = = = = Optional shaft at motor speed (terminal box end only) mm dia. mm long. Approx. weight: SD MIS. Kg

38 Type: LIS Speed Range:. r.p.m. In Line Reduction MultiSpur Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD LIS SD LIS (T.E.F.C.) SD LIS Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages, and for full details. On request gearbox available without feet, can be mounted off of gearbox spigot tappings. ( Nm =. lbs. ins.) ( Nm =. cmkp) r.p.m. PINION : : : : : : : : : : : SPUR : : : : : : : : SD LIS SD LIS SD LIS SD LIS SD LIS SD LIS SD LIS or Phase watts or Phase watts Phase Capacitor Start Induction Run watts Phase watts Phase watts 0 00 r.p.m. 0 PINION : : : : : : : : : : : SPUR : : : : : : : : SD LIS SD LIS SD LIS SD LIS SD LIS SD LIS SD LIS or Phase 0 watts Phase watts Phase watts Phase Capacitor Start Induction Run watts Phase watts Phase watts r.p.m.. 0 PINION : : : : : : : : : : : SPUR : : : : : : : : SD LIS SD LIS Phase Phase watts watts SD LIS SD LIS Phase Phase watts 0 watts

39 Dimensions in mm. Scale : NB: Unit drawn is SD LIS mm dia. h. SD LIS = SD LIS = (nts) (T.E.F.C.) Keyway mm mm long. SD LIS = SD LIS =... Ø. Alternative shaft position on request.. Ø Ø Leads out here cm. holes on 0mm P.C.D. Can be tapped M mm deep. Ø 0 Optional shaft at motor speed (lead end only) see separate motor drawing for details (Page ). Not applicable to T.E.F.C. units... x. SD LIS SD LIS Motor C L Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD LIS. Kg SD LIS. Kg Induction & Ph mm dia. h. Keyway mm mm long.. Ø. SD LIS = SD LIS = Dimensions in mm. Scale : NB: Unit drawn is SD LIS Tapped 0mm conduit or PG. on request. holes on 0mm P.C.D. Can be tapped M mm deep. Ø Motor C L SD LIS SD LIS... Ø. Alternative shaft position on request. Optional shaft at motor speed (terminal box end only) see separate motor drawing for details (Page )... x. Approx. weight: SD LIS.0 Kg SD LIS. Kg mm dia. h. Keyway mm mm long.... Ø. (T.E.F.C.) Dimensions in mm. Scale : Ø Ø holes on 0mm P.C.D. Can be tapped M mm deep. Ø. SD LIS Motor C L Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Alternative shaft position on request.. Leads out here cm.. x. Optional shaft at motor speed (lead end only) mm dia. mm long. Not applicable to T.E.F.C. units. Approx. weight: SD LIS.0 Kg mm dia. h. Keyway mm mm long. Dimensions in mm. Scale : Electrolytic capacitor when necessary. holes on0mm P.C.D. Can be tapped M mm deep. Ø SD LIS. Motor C L... Ø. Ø. Alternative shaft position on request.. Tapped 0mm conduit or PG. on request... x. Optional shaft at motor speed (terminal box end only) mm dia. mm long. Approx. weight: SD LIS.0 Kg

40 Type: SWS Speed Range: r.p.m. Worm and MultiSpur Reduction Gear Unit or Phase Induction Motor Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) (SD only) SD SWS SD SWS Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD SWS SD SWS r.p.m. Phase or Phase WORM : : : : : : : : : : : SPUR watts watts r.p.m WORM : : : : : : : : : : : SPUR SD SWS SD SWS Phase or Phase 0 watts watts..... Optional terminal box tapped 0mm conduit or PG. on request. Standard entry position R.H.S. (Not available on SD ). SD SWS = SD SWS = 0 Dimensions in mm. Scale : NB: Unit drawn is SD SWS. Ø SD SWS SD SWS mm dia. h. with mm flat. long. Available both sides. 0. Motor C L Ø Ø.. 0 holes tapped M mm deep. Leads out here cm. Optional shaft at motor speed (lead end only).mm dia. mm long. Approx. weight: SD SWS. Kg SD SWS. Kg

41 Worm and MultiSpur Reduction Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) Type: MWS Speed Range: 0. r.p.m. Voltage, Construction, Connections, Motor Performance and Optional Extras see pages and for full details. r.p.m WORM SPUR 0:.: :.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: watts SD MWS SD MWS SD MWS SD MWS watts SD MWS 00 r.p.m WORM SPUR 0:.: :.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: watts Minimum speed of 0. r.p.m. Obtainable using 00 r.p.m. SD/ ( Nm =. lbs. ins.) Nm =. cmkp SD MWS SD MWS SD MWS 0 watts Induction & Ph Ø 0 Ø 0 SD MWS = SD MWS (T.E.F.C.) = 0 SD MWS = Optional (either side): holes on mm P.C.D. Can be tapped M mm deep. Dimensions in mm. Scale : NB: Unit drawn is SD MWS SD MWS Ø SD MWS = Ø mm dia. h. Keyway mm mm long. Available both sides. Motor C L. holes tapped M mm deep. 0 SD MWS (T.E.F.C.) = Leads out here cm SD MWS Optional shaft at motor speed (lead end only) see separate motor drawing for details (Page ). Not applicable to T.E.F.C. units. SD MWS Optional shaft at motor speed (lead end only).mm dia. mm long. 0 Dimensions in mm. Scale : Tapped 0mm conduit or PG. on request. Ø mm dia. h. Keyway mm mm long. Available both sides. Ø.. SD MWS = Motor C Motor C L L SD MWS SD MWS Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD MWS. Kg SD MWS. Kg SD MWS Optional (either side): holes on mm P.C.D. Can be tapped M mm deep. holes tapped M mm deep. 0 Motor C L. 0 Optional shaft at motor speed (terminal box end only) see separate motor drawing for details (Page ). Approx weight: SD MWS.0 Kg

42 Type: LWS Speed Range: 0. 0 r.p.m. Worm and MultiSpur Reduction Gear Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) SD LWS SD LWS SD LWS (T.E.F.C.) SD LWS Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages, and for full details. Minimum speed of 0. r.p.m. obtainable using 00 r.p.m. motor (SD //). On request gearbox available without feet, can be mounted off of gearbox spigot tappings. Note: mm diameter shaft available with gear ratio s :, :. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD LWS Phase Capacitor r.p.m. watts WORM : : 0: : /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SPUR : : : : : : : : : : : : : : : : : SD LWS SD LWS SD LWS SD LWS or Phase or Phase watts watts. SD LWS Phase Capacitor Start Induction Run watts 0.. SD LWS SD LWS Phase Phase watts 0 watts 00 r.p.m WORM : 0: : /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SPUR : : : : : : : : : : : : : : SD LWS SD LWS SD LWS SD LWS SD LWS SD LWS SD LWS SD LWS Phase Capacitor 0 watts or Phase 0 watts Phase watts Phase watts Phase Capacitor Start Induction Run watts Phase watts Phase watts

43 holes on 0mm P.C.D. Can be tapped M mm deep. Ø Dimensions in mm. Scale : mm dia. h. Keyway mm mm long. Ø.. Motor C L SD LWS.. x. Optional shaft at motor speed (lead end only).mm dia. mm long. holes on 0mm P.C.D. Can be tapped M mm deep.. Ø Leads out here cm SD LWS = 0 SD LWS = (T.E.F.C.) SD LWS = 0 SD LWS = Ø. x... Alternative shaft position on request. Dimensions in mm. Scale : NB: Unit drawn is SD LWS Ø Ø Leads out here cm mm dia. h. Keyway mm mm long... Alternative shaft position on request. Ø... Optional shaft at motor speed (lead end only) see separate motor drawing for details (Page ). Not applicable to T.E.F.C. units... Approx. weight: SD LWS. Kg 0. SD LWS SD LWS Motor C L Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). SD LWS. Kg Approx. weight: SD LWS. Kg Induction & Ph holes on 0mm P.C.D. Can be tapped M mm deep. SD LWS = SD LWS = Ø Ø Dimensions in mm. Scale : NB: Unit drawn is SD LWS mm dia. h Keyway mm mm long. Ø.. Motor C L SD LWS SD LWS Tapped 0mm conduit or PG. on request x. Optional shaft at motor speed (terminal box end only) see separate motor drawing for details (Page ). Alternative shaft position on request.. SD LWS. Kg Approx. weight: SD LWS. Kg holes on 0mm P.C.D. Can be tapped M mm deep.. Ø. (T.E.F.C.) x. Leads out here cm Dimensions in mm. Scale : Ø Ø mm dia. h. Keyway mm mm long. Optional shaft at motor speed (lead end only) mm dia. mm long. Not applicable to T.E.F.C. units... Ø. Alternative shaft position on request.... SD LWS Motor C L Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD LWS. Kg holes on 0mm P.C.D. Can be tapped M mm deep. Ø Dimensions in mm. Scale : Electrolytic capacitor when necessary. mm dia. h. Keyway mm mm long. Ø.. SD LWS Motor C L Ø. Tapped 0mm conduit or PG. on request... x. Optional shaft at motor speed (terminal box end only) mm dia. mm long... Alternative shaft position on request Alternative shaft position on request... Approx. weight: SD LWS. Kg

44 Type: GWS Speed Range: 0. 0 r.p.m. Worm and MultiSpur Reduction Units or Phase Induction Motors Constant Speed Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box or T.E.F.C. (IP ) GWS gearbox with hollow shaft available on request (mm I/D with mm keyway). SD GWS SD GWS (T.E.F.C.) SD GWS (T.E.F.C.) with hollow shaft Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages, and for full details. Minimum speed of 0. r.p.m. obtainable with 00 r.p.m. motor (SD /). ( Nm =. lbs. ins.) ( Nm =. cmkp) r.p.m. SD GWS SD GWS SD GWS SD GWS SD GWS or Phase watts Phase w Phase w Phase Cap Start Induction Run w TEFC Phase w WORM SPUR : /: /: /: /: /: /: /: /: /: /: /: /: /: 0: 0: 0: 0: 0: : : : : : : r.p.m. SD GWS SD GWS SD GWS SD GWS SD GWS Phase w Phase w Phase w Phase w Phase Cap Start Induction Run w Phase 0 w WORM SPUR : /: /: /: /: /: /: /: /: /: /: /: /: /: 0: 0: 0: 0: 0: : : : : : : Dimensions in mm. Scale :. SD GWS Ø.. Ø Ø. Tapped 0mm conduit or PG. on request. Motor C L Optional (either side): holes on mm P.C.D. Can be tapped M mm deep. = = = = holes tapped M 0mm deep. mm dia. h Keyway mm mm long. Available both sides. Also available with hollow shaft (mm I/D with mm keyway). Motor C L Optional shaft at motor speed (terminal box end only) see separate motor drawing for details. (page ). Approx. weight: SD GWS. Kg

45 (T.E.F.C.) Dimensions in mm. Scale :. SD GWS Ø... = = Optional (either side): holes on mm P.C.D. Can be tapped M mm deep. holes tapped M 0mm deep. Optional shaft at motor speed (lead end only) see separate motor drawing for details (Page ). Not applicable to T.E.F.C. units. Ø Leads out here cm Ø Ø mm dia. h. Keyway mm mm long. Available both sides. Also available with hollow shaft (mm I/D with mm keyway). 0 Motor C L Motor C Optional terminal box L tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Approx. weight: SD GWS.0Kg Induction & Ph SD GWS = SD GWS = 0 Dimensions in mm. Scale : NB: Unit drawn is SD GWS Tapped 0mm conduit or PG. on request.. SD GWS SD GWS Ø. Electrolytic capacitor when necessary... Ø Ø. Optional (either side): holes on mm P.C.D. Can be tapped M mm deep. = = holes tapped M 0mm deep. Optional shaft at motor speed (terminal box end only) mm dia. mm long. mm dia. h. Keyway mm mm long. Available both sides. Also available with hollow shaft (mm I/D with mm keyway). Approx. weight:sd GWS.0 Kg SD GWS.0 Kg Dimensions in mm. Scale : NB: Unit drawn is SD GWS SD GWS (T.E.F.C.) = SD GWS (T.E.F.C.) = SD GWS =. SD GWS SD GWS Ø.. Ø Ø Ø Motor C L Motor C L. Leads out here cm Motor C L = = Optional (either side): holes on mm P.C.D. Can be tapped M mm deep. holes tapped M 0mm deep. mm dia. h. Keyway mm mm long. Available both sides. Also available with hollow shaft (mm I/D with mm keyway). Motor C L Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. (Standard on T.E.F.C. units). Optional shaft at motor speed (lead end only) mm dia. mm long. Not applicable to T.E.F.C. units. Approx. weight: SD GWS.0 Kg SD GWS (T.E.F.C.).0 Kg

46 Characteristics of Commutator Motors SPEED FULL LOAD TORQUE Series Wound Motors Shown is a typical torque/speed characteristic for series wound motors. Series wound motors can be wound for A.C. or D.C. supply. A.C. wound units when operated from a similar D.C. voltage will have approximately % increase in output. Suitable for reversing as standard i.e. leads brought out (two armature and two field). Series motors can be supplied as lead reversing (split field) (the motor runs on one field coil at a time with approximately % power loss), change of direction being affected by a single pole switch. As will be seen from the characteristic the speed varies inversely with the load, consequently series wound motors should not be oversized for their particular application as this will result in the motor running at much higher speeds than required. It is possible to control the speed of this type of motor by means of a variable resistance transformer in a ratio : although this can vary depending on the application. SPEED FULL LOAD TORQUE Shunt Wound Motors Shown is a typical torque/speed characteristic for D.C. shunt wound motors. This type of unit has constant speed characteristics, the difference between no load and full load speed being between % and 0% of rated speed. Suitable for reversing as standard i.e. leads brought out (two armature and two fields). The speed can be controlled by means of a variable resistance in series with the armature by a ratio of approximately :, however this can vary considerably depending on the application. Alternatively if an A.C. supply is available a speed range of up to can be obtained by means of a D.C. thyristor controller. IMPORTANT: It must be noted, in mind when reducing the motor speed the armature cooling fan efficiency drops and therefore it is wise to reduce the rating or load of the motor by 0% over a speed range of : and by 0% for a speed range of. Connection Diagrams for Wound Field Commutator Motors Series Wound Lead Series Wound Lead Reversing (SplitSeries) Field ARMATURE Field ARMATURE Field Supply Field Supply Supply If speed control required insert rheostat thus If speed control required insert rheostat thus Red Reverse rotation Series Wound Lead Reversing D.C. Shunt Wound Field Field Red ARMATURE Red If speed control required insert rheostat thus Red Supply ARMATURE If speed control required insert rheostat thus Red Supply Supply Field Join and insulate Reverse rotation Field Reverse rotation

47 Parvalux ElectroMagnetic (Fail Safe) Stop Brakes for Commutator Motors For frequent stop/starts (more than per minute) please contact our sales engineers. A B C Brake Size PPP TYPE Input Power Input Volts Rated Torque Recommended Motor Frames SD and SD Weight g Brake Size PPP Recommended Motor Frame SD P P P DIMENSIONS APPROVALS TYPE P P P VA (w) 0v A.C. 0. Nm VA (w) v A.C. 0. Nm VA (w) v D.C. 0. Nm A B C All dimensions in (mm) A: inc adaptor plate core cable 0cm long minimum. C.S.A CUS C.E. Rec. Class F ENCLOSURE IP Input Power Input Volts Rated Torque VA (w) 0v A.C. Nm VA (w) v A.C. Nm VA (w) v D.C. Nm DIMENSIONS A B C All dimensions in (mm) A: inc adaptor plate These singledisc electro magnetic brakes are spring applied electrically released units which provide fail safe operating characteristics, that on interruption, or failure of power supply, the brake will engage and arrest the load. These brakes operate from single phase A.C. supply (not P or P) and incorporate a built in rectifier. This offers the brake a vibration free characteristic through a lower operating voltage spectrum. Commutator series/shunt Motor and Brake Wiring Diagram D.C. or A.C. Series Wound D.C. Shunt Wound (A.C. Stop Brake) Field Field B Field B ARMATURE Double Pole Switch L BRAKE BRAKE ARMATURE Double Pole Switch N If speed control required insert rheostat thus Using this method of connection motor and brake must be suitable for the same supply D.C. Supply Separate A.C. Supply EMC Filter (unless declined in writing by customer, will be supplied) EMC FILTER mm dia. x mm long with mm fixing stud and nut. mm long. Lead length cm. For use with commutator and permanent magnet motor, to reduce the emissions the motor might make which could affect adjacent sensitive equipment. The filter is connected between the supply and the motor.

48 Motor Types: SD SD SD Commutator Type Motors Variable Speed A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard SD Ventilated Internal Fan Cooled (IP 0) SD SD Drip Proof Internal Fan Cooled (IP ) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) SD TV SD SD SD Voltage Range: v v, /v, 00/0v and /0v, A.C. Series D.C. Shunt or Series. Special voltages quoted for on request. See data column for minimum voltages. Starting Current: Approximately times full load. Rotation: Reversible four leads as standard. Construction: Motors Shielded ball bearings spring loaded for quiet running. Single Reduction es: Fitted with ball bearings, alloy gearbox with composite gear, grease lubricated for life and suitable for mounting in any position. InLine Double Reduction es: Fitted with ball bearings, alloy gearbox with composite gear, grease or oil bath lubricated for life and suitable for mounting in any position. Spur Reduction es: Fitted with ball bearings, alloy gearbox with composite pinion gear and multispur type hardened steel gears, oil bath lubricated for life. Suitable for mounting in any position. Connections: cm P.V.C. flexible (Terminal box on request). Optional Extras: Double ended motor spindles. Double ended gear shafts (not available on inline units). Non standard shafts (stainless steel, keyways, flats, etc). Terminal box. (not SD T.V.). Totally enclosed half hour rating. (SD T.V. reduced length). Holes tapped for spigot mounting. lead reversing (split series) % reduction in torque. Radio and T.V. suppression (class B insulation). ElectroMagnetic Brake: Page. Thyristor D.C. Controller: Contact Parvalux. Tachogenerator: Page. Additional Extras for Geared Units: Non standard catalogue reductions available on request. Bronze Gears: Single and double reduction final gears. Flange Mounting Details: Page. Shaft Positions: Page. Insulation: Class F (maximum temperature rise C at a maximum ambient of 0 C). s: B.S. 000 part. (I.E.C. ). (CSA CUS if required). SD FULL LOAD OUTPUT WATTS Series Wound INPUT CURRENT (AMPS) 0V A.C. 0V A.C. INPUT WATTS MINIMUM VOLTAGE AVAILABLE SD FULL LOAD OUTPUT WATTS Shunt Wound INPUT CURRENT (AMPS) 0V D.C. 0V D.C.. INPUT WATTS MINIMUM VOLTAGE AVAILABLE *000 V D.C. 0. 0V D.C *Maximum voltage for this output is v D.C. SD FULL LOAD OUTPUT WATTS Series Wound INPUT CURRENT (AMPS) 0V A.C. 0V A.C. INPUT WATTS MINIMUM VOLTAGE AVAILABLE SD FULL LOAD OUTPUT WATTS Shunt Wound INPUT CURRENT (AMPS) 0V D.C. 0V D.C.. INPUT WATTS MINIMUM VOLTAGE AVAILABLE SD FULL LOAD OUTPUT WATTS Series Wound INPUT CURRENT (AMPS) 0V A.C. 0V A.C. INPUT WATTS MINIMUM VOLTAGE AVAILABLE SD FULL LOAD OUTPUT WATTS Shunt Wound INPUT CURRENT (AMPS) 0V D.C. 0V D.C.. INPUT WATTS MINIMUM VOLTAGE AVAILABLE Shunt wound motor outputs are based on a pure D.C. supply (i.e. form factor ) with electronic control, outputs will be reduced, to what degree depends on the form factor (FF) and the matching of motor and controller. We recommend a controller range to give the best performance and brush life.

49 . (SD) (SD T.V.) Dimensions in mm. Scale : holes on.mm P.C.D. Can be tapped M mm deep. Ø 0. Ø Ø. M spigot, see note SD.0 Ø. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position entry R.H.S. (Not available on SD T.V.) (SD). (SD T.V.) Leads out here cm 0. Plan of base with plate removed.. holes can be tapped M mm deep... Spigot M can be machined to./.mm dia. concentric with shaft 0.0mm T.I.R. Optional shaft at lead end,.mm dia. mm long.. Ø.. Dimensions in mm. Scale : holes on.mm P.C.D. Can be tapped M mm deep. holes on.mm P.C.D. Can be tapped M mm deep. Ø Ø Ø Ø. Approx. weight: SD. Kg SD. M spigot, see note holes on.mm P.C.D. Can be tapped M mm deep. Commutator series/shunt Leads out here cm 0 Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down..... holes can be tapped M mm deep. Plan of base with plate removed. Spigot M can be machined to./.mm dia. concentric with shaft 0.0mm T.I.R. Optional shaft at lead end,.mm dia. mm long... Approx. weight: SD. Kg. Dimensions in mm. Scale : holes on.mm P.C.D. Can be tapped M mm deep. holes on.mm P.C.D. Can be tapped M mm deep. Ø Ø Ø Ø SD M spigot, see note. Ø.00.. Leads out here cm.. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down... holes can be tapped M.mm deep. Plan of base with plate removed.. Spigot M can be machined to./.mm dia. concentric with shaft 0.0mm T.I.R. Optional shaft at lead end, mm dia. mm long.. Approx. weight: SD. Kg

50 Type: S Speed Range: 0 r.p.m. Single Reduction Worm Gear Units Variable Speed A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) SD S SD S with terminal box SD S with brake Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD S Series 00 r.p.m. watts : : 0: : : : 0: : : : : /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: COMPOSITE SD S Shunt watts COMPOSITE r.p.m : : 0: : : : 0: : : : : /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SD S Series 0 watts COMPOSITE SD S Shunt 0 watts COMPOSITE

51 Dimensions in mm. Scale : SD S (SD S) (SD S T.V.) mm dia. h. Flat mm mm long. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position entry R.H.S. (Not available on SD T.V.) (SD S). (SD S T.V.). 0.. Leads out here cm.. holes can be tapped M mm deep. Plan of base with plate removed.. Optional shaft at motor speed (lead end only).mm dia. mm long.. Approx. weight: SD S.0 Kg Commutator series/shunt

52 Type: M or MB Speed Range: 0 r.p.m. Single Reduction Worm Gear Units Variable Speed A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard SD Ventilated Internal Fan Cooled (IP 0) SD SD Drip Proof Internal Fan Cooled (IP ) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) SD MF SD MB SD M SD MB Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. Hollow shaft. Available on request maximum internal diameter mm. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD M/MB Shunt 000 r.p.m. 0 watts : : 0: : : : 0: : : : : /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: COMPOSITE SD M/MB Shunt 0 watts COMPOSITE r.p.m : : 0: : : : 0: : : : : /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SD M/MB SD M/MB SD M/MB Series/Shunt Series Shunt Series Shunt watts COMPOSITE watts COMPOSITE COMPOSITE COMPOSITE watts watts watts COMPOSITE r.p.m : : 0: : : : 0: : : : : /: 0 /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SD M/MB SD M/MB SD M/MB Series/Shunt Series Shunt Series Series 0 watts watts watts watts watts Shunt watts COMPOSITE COMPOSITE COMPOSITE COMPOSITE COMPOSITE COMPOSITE

53 0. Dimensions in mm. Scale : 0 (SD MB) (SD MB T.V.) Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position entry R.H.S. (Not available on SD T.V.). SD MB SD M = SD M = Leads out here cm.. x. mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter.. Optional shaft at motor speed (lead end only).mm dia. mm long. Approx. weight: SD MB. Kg Dimensions in mm. Scale : NB: Unit drawn is SD M mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. SD = SD =. SD = 0 SD = SD M = Ø SD M = Ø. SD M = SD M = SD M SD M SD M = SD M = Commutator series/shunt SD M = SD M =. Leads out here cm Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down.. holes can be tapped M mm deep. SD =. SD = SD M SD M SD =. SD = SD M.. SD M... SDM SDM. SD M Optional shaft at motor speed (lead end only).mm dia. mm long. SD M Optional shaft at motor speed (lead end only) mm dia. mm long. Approx. weight: SD M. Kg SD M. Kg 0. SD MB = SD MB = Dimensions in mm. Scale : NB: Unit drawn is SD MB SD = MB Ø SD = MB Ø SD MB = SD MB = SD MB SD MB SD MB = SD MB = x. Leads out here cm mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter.. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. SD M Optional shaft at motor speed (lead end only).mm dia. mm long. SD M Optional shaft at motor speed (lead end only) mm dia. mm long. Approx. weight: SD MB.0 Kg SD MB. Kg

54 Type: L/LB/LH/LHB Speed Range: 0 r.p.m. Single Reduction Worm Gear Units Variable Speed A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard SD SD Drip Proof Internal Fan Cooled (IP ) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) SD L SD LB SD LF Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. LH/LHB for hollow shaft details see page. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD L/LB/LH/LHB 000 r.p.m. Series Shunt : 0: 0: : 0 /: /: /: : / /: /: 0 watts COMPOSITE watts COMPOSITE r.p.m : 0: 0: : 0 /: /: /: /: /: /: SD L/LB/LH/LHB Series Shunt watts COMPOSITE watts COMPOSITE r.p.m : 0: 0: : 0 /: /: /: /: /: /: SD L/LB/LH/LHB Series Shunt watts COMPOSITE BRONZE COMPOSITE BRONZE watts

55 Dimensions in mm. Scale : Ø SD L. 0 mm dia. h. Keyway mm mm long. Alternative, LH gearbox with mm inside dia. hollow shaft (mm external dia.) Also available with solid shaft up to mm dia. Length as required. Plan of base with plate removed... Optional shaft at motor speed (lead end only) mm dia. mm long. Leads out here cm. holes can be tapped M.mm deep..... Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. Approx. weight: SD L.0 Kg Commutator series/shunt Dimensions in mm. Scale : SD LB 0 Ø Leads out here cm 0 x. Optional shaft at motor speed (lead end only) mm dia. mm long. mm dia. h. Keyway mm mm long. Alternative, LHB gearbox with mm inside dia. hollow shaft (mm outside dia.) Also available with solid shaft up to mm dia. Length as required. 0 0 Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. Approx. weight: SD LB. Kg Dimensions in mm. Scale : holes on mm P.C.D. tapped M. LF Mounting Flange Details Ø Ø mm dia. h. Keyway mm mm long. Approx. weight: Mounting Flange 0. Kg

56 Type: SS Speed Range: 0 r.p.m. Double Reduction Worm Gear Units Variable Speed A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) SD SS SD SS with brake SD SS with terminal box Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) 00 r.p.m * : : : : 0: : 0: : : : : : Series watts SD SS Series watts COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE Shunt watts BRONZE r.p.m * 0: : : : : : : : : 0: Series watts SD SS Series 0 watts COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE.... *Ratios are for guidance only and may be varied Shunt 0 watts BRONZE..

57 00 (SD SS) (SD SS T.V.) Dimensions in mm. Scale : Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position entry R.H.S. (Not available on SD T.V.). SD SS mm dia. h. Flat mm mm long (SD SS) 0. (SD SS T.V.) Leads out here cm holes can be tapped M mm deep. Plan of base with plate removed.. Optional shaft at motor speed (lead end only).mm dia. mm long.. Approx. weight: SD SS.0 Kg Commutator series/shunt

58 Type: MM or MBM Speed Range: 0 r.p.m. Double Reduction Worm Gear Units Variable Speed A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard SD Ventilated Internal Fan Cooled (IP 0) SD SD Drip Proof Internal Fan Cooled (IP ) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) SD MBM SD MM SD MM Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) 000 r.p.m. * 0: : : : : Maximum voltage V D.C. Series watts SD MM/MBM Shunt watts Series watts SD MM/MBM COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE Shunt 0 watts BRONZE 00 r.p.m. 0 * : : : : : Series watts SD MM/MBM Shunt watts Series watts SD MM/MBM COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE Shunt watts BRONZE 000 r.p.m * : : : : : : Series watts *Ratios are for guidance only and may be varied. SD MM/MBM Shunt watts Series watts SD MM/MBM COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE Shunt watts BRONZE..

59 mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. (SD MBM) Dimensions in mm. Scale : (SD MBM T.V.) Optional terminal box tapped 0mm conduit or PG. on request. Shown standard entry position R.H.S. (Not available on SD T.V.).. SD MBM. 0 Leads out here cm 0.. x.. Optional shaft at motor speed (lead end only).mm dia. mm long.. SD MM = SD MM = mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. Leads out here cm Dimensions in mm. Scale : NB: Unit drawn is SD MM SD MM = SD MM = SD MM = SD MM =. SD MM = 0. SD MM = Approx. weight: SD MBM.0 Kg.. SD MM Ø SD MM Ø SD = SD =. SD MM SD MM. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. Commutator series/shunt holes can be tapped M mm deep. SD =. SD = SD SD SD = SD =. SD SD.. Plan of base with plate removed.. SD SD. SD MM Optional shaft at motor speed (lead end only).mm dia. mm long. SD MM Optional shaft at motor speed (lead end only) mm dia. mm long. Approx. weight: SD MM. Kg SD MM. Kg mm dia. h. Keyway mm mm long. Alternative, hollow shaft mm inside diameter. SD MBM = SD MBM = Dimensions in mm. Scale : NB: Unit drawn is SD MBM SD c = SD c =. SD MBM SD MBM 0. SD MBM Ø SD MBM Ø SD MBM = SD MBM =... x. Leads out here cm. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. SD MM Optional shaft at motor speed (lead end only).mm dia. mm long. SD MM Optional shaft at motor speed (lead end only) mm dia. mm long. Approx. weight: SD MBM.0 Kg SD MBM. Kg

60 Type: SIW Speed Range:. r.p.m. In Line Double Reduction Worm Gear Units A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) SD SIW Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) r.p.m. INT COMPOSITE : : /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SD SIW Series/Shunt watts BRONZE r.p.m. INT COMPOSITE : : /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SD SIW Series/Shunt watts BRONZE....

61 0 Dimensions in mm. Scale : SD SIW (SD SIW) (SD SIW T.V.) mm dia. h. Flat mm wide mm long.. holes on.mm P.C.D. Can be tapped M mm deep. holes can be tapped M mm deep. Leads out here cm Ø 0. Ø. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position entry R.H.S. (Not available on SD T.V.). Optional shaft at motor speed (lead end only).mm dia. mm long. Approx. weight: SD SIW. Kg Commutator series/shunt

62 Type: MIW Speed Range:. r.p.m. In Line Double Reduction Worm Gear Units A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard SD Ventilated Internal Fan Cooled (IP 0) SD Drip Proof Internal Fan Cooled (IP ) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) SD MIW SD MIW Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD MIW 000 r.p.m. Series Shunt.. 0 INT : : /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: watts watts SD MIW Series Shunt watts 0 watts COMPOSITE COMPOSITE COMPOSITE BRONZE COMPOSITE BRONZE r.p.m INT : : /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SD MIW Series Shunt watts watts SD MIW Series Shunt watts watts COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE

63 Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position entry R.H.S. (Not available on SD T.V.)... 0 (SD MIW) (SD MIW T.V.) Dimensions in mm. Scale : holes on.mm P.C.D. Can be tapped M mm deep.. SD MIW. Ø. Ø. 0 Leads out here cm mm dia. h. Keyway mm mm long.. holes tapped M mm deep.. Optional shaft at motor speed (lead end only).mm dia. mm long... Dimensions in mm. Scale : holes on.mm P.C.D. Can be tapped M mm deep. 0 Ø. Approx. weight: SD MIW. Kg SD MIW. Ø. Commutator series/shunt Ø. Motor C L Motor C L mm dia. h. Keyway mm mm long.. holes tapped M mm deep. Leads out here cm. 0 Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. Optional shaft at motor speed (lead end only).mm dia. mm long. Approx. weight: SD MIW. Kg

64 Type: LIW Speed Range:. r.p.m. In Line Double Reduction Worm Gear Units Variable Speed A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard SD SD Drip Proof Internal Fan Cooled (IP ) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) SD LIW SD LIW with brake SD LIW Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD LIW Series Shunt 000 r.p.m GEAR INT 0: : : : 0 /: /: /: /: /: /: /: /: /: /: /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: : : : : : watts 0 watts SD LIW Series Shunt 0 watts 0 watts COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE 00 r.p.m GEAR INT 0: : : : 0 /: /: /: /: /: /: /: /: /: /: /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: 0 /: : : : : : SD LIW Series Shunt watts watts SD LIW Series Shunt watts watts COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE COMPOSITE BRONZE 0 0

65 mm dia. h. Keyway mm mm long... Dimensions in mm. Scale : holes on.mm P.C.D. Can be tapped M mm deep.. SD LIW 0. Motor C L Ø Ø. Ø. 0.. Optional shaft at motor speed (lead end only).mm dia. mm long. mm dia. h. Keyway mm mm long. holes can be tapped M mm deep... Leads out here cm Dimensions in mm. Scale : holes on.mm P.C.D. Can be tapped M mm deep. 0.. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. Approx. weight: SD LIW. Kg SD LIW 0. Motor C L Ø. Commutator series/shunt Ø. holes can be tapped M mm deep. 0 Ø Leads out here cm. 0.. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. Optional shaft at motor speed (lead end only) mm dia. mm long. Approx. weight: SD LIW.0 Kg

66 Type: SIS Speed Range:. r.p.m. In Line Reduction MultiSpur Gear Units Variable Speed A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) SD SIS Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) *000 r.p.m. SD SIS Series/Shunt watts SD SIS with brake 00 r.p.m. SD SIS Series/Shunt watts SD SISF with brake 00 r.p.m. SD SIS Series/Shunt watts *Maximum voltage shunt wound for this output is V D.C Optional mounting flange (see below).. (SD SIS) (SD SIS T.V.) Dimensions in mm. Scale : Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position entry R.H.S. (Not available on SD T.V.). Ø Ø Ø SD SIS 0 mm dia. h. Flat mm mm long. 0.. holes tapped M mm deep. Optional shaft at motor speed (lead end only).mm dia. mm long. Leads out here cm 0 holes on.mm P.C.D. Can be tapped M mm deep. Approx. weight: SD SIS. Kg Dimensions in mm. Scale : S Optional Plastic Mounting Flange. Ø. Ø equally spaced holes on.mm P.C.D. cored.mm dia. SIS standard shaft extension Ø

67 In Line Reduction MultiSpur Gear Units Variable Speed A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard SD SD Drip Proof Internal Fan Cooled (IP ) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) Type: MIS Speed Range: 0 r.p.m. Voltage, Construction, Connections, Motor Performance s and Optional Extras see page for full details. 000 r.p.m. 0 0 PINION SPUR SD MIS Series Motor Rating watts. 0. Shunt Motor Rating 0 watts Series Motor Rating 0 watts.. SD MIS.. Shunt Motor Rating 0 watts. SD MIS 00 r.p.m. Dimensions in mm. Scale : PINION SPUR ( Nm =. cmkp) SD MIS SD MIS Series Motor Rating watts... Shunt Motor Rating watts Series Motor Rating watts Shunt Motor Rating watts 0.. SD MIS Commutator series/shunt mm dia. h. Keyway mm mm long.. Ø 0. Ø. Leads out here cm. holes on mm P.C.D. Can be tapped M mm deep. holes tapped M mm deep. Ø 0 = = Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. 0 = = Optional shaft at motor speed (lead end only).mm dia. mm long. Approx. weight: SD MIS. Kg Dimensions in mm. Scale : SD MIS. mm dia. h. Keyway mm mm long.. Ø 0. Motor CL Ø. Motor C L Leads out here cm. holes on mm P.C.D. Can be tapped M mm deep. holes tapped M mm deep. Ø 0 = = Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. 0 = = Optional shaft at motor speed (lead end only) mm dia. mm long. Approx. weight: SD MIS. Kg

68 Type: LIS Speed Range: 00 r.p.m. In Line Reduction MultiSpur Gear Units Variable Speed A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard SD SD Drip Proof Internal Fan Cooled (IP ) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) SD LIS SD LIS SD LIS with brake Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. On request gearbox available without feet, can be mounted off of gearbox spigot tappings. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD LIS 000 r.p.m. Series Shunt 0 0 PINION : : : : : : : : : : : SPUR : : : : : : : : watts 0 watts 0 SD LIS Series Shunt 0 watts 0 0 watts 00 r.p.m. 0 0 PINION : : : : : : : : : : : SPUR : : : : : : : : SD LIS Series Shunt watts watts 00 r.p.m PINION : : : : : : : : : : : SPUR : : : : : : : : SD LIS Series Shunt watts 0. watts SD LIS Series Shunt watts watts 0.

69 mm dia. h. Keyway mm mm long. Dimensions in mm. Scale : holes on 0mm P.C.D. Can be tapped M mm deep. SD LIS Ø.. Ø.. Ø. Motor C L Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. Alternative shaft position on request.. Optional shaft at motor speed (lead end only).mm dia. mm long. mm dia. h. Keyway mm mm long... Ø.. Leads out here cm Dimensions in mm. Scale : holes can be tapped M mm deep.. holes on 0mm P.C.D. Can be tapped M mm deep. Ø Ø x. Approx. weight: SD LIS. Kg. Motor C L SD LIS Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. Commutator series/shunt Alternative shaft position on request.. Leads out here cm.. x. Optional shaft at motor speed (lead end only) mm dia. mm long. Approx. weight: SD LIS. Kg

70 Type: SWS Speed Range:. r.p.m. Worm and MultiSpur Reduction Gear Unit Variable Speed A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard SD Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) SD SWS Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD SWS Series/shunt 00 r.p.m. watts WORM : : : : : : : : : : : SPUR.:.:.:.:.:.:.:.:.:.:.: OUTPUT TORQUE (Nm) r.p.m WORM : : : : : : : : : : : SPUR.:.:.:.:.:.:.:.:.:.:.: SD SWS Series/shunt watts OUTPUT TORQUE (Nm)..... (SD SWS) (SD SWS T.V.) Dimensions in mm. Scale : Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position entry R.H.S. (Not available on SD T.V.).. SD SWS mm dia. h. with mm flat.mm long. Available both sides. 0 Motor C L 0 Ø Ø Leads out here cm... 0 holes tapped M mm deep.. Optional shaft at motor speed (lead end only).mm dia. mm long. Approx. weight: SD SWS.0 Kg

71 Worm and MultiSpur Reduction Gear Units Variable Speed A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard SD Ventilated Internal Fan Cooled (IP 0) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) Type: MWS Speed Range:. r.p.m. SD MWS Voltage, Construction, Connections, Motor Performance s and Optional Extras see page for full details. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD MWS Series/shunt 000 r.p.m... 0 WORM SPUR 0:.: :.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: watts OUTPUT TORQUE (Nm) r.p.m WORM SPUR 0:.: :.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: SD MWS Series/shunt watts OUTPUT TORQUE (Nm) r.p.m... WORM SPUR 0:.: :.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: /:.: SD MWS Series/shunt 0 watts OUTPUT TORQUE (Nm) Commutator series/shunt Dimensions in mm. Scale : SD MWS (SD MWS) (SD MWS T.V.) Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position entry R.H.S. (Not available on SD T.V.).. 0. Ø 0 0 Ø 0 Leads out here cm. Motor C L Optional (either side): holes on mm P.C.D. Can be tapped M mm deep. Motor C L. holes tapped M mm deep. mm dia. h. Keyway mm mm long. Available both sides. 0 Optional shaft at motor speed (lead end only).mm dia. mm long. Approx. weight: SD MWS. Kg

72 Type: LWS Speed Range: 0. 0 r.p.m. Worm and MultiSpur Reduction Gear Units Variable Speed A.C. D.C. Series or D.C. Shunt Wound Enclosures: Standard SD Ventilated Internal Fan Cooled (IP 0) SD SD Drip Proof Internal Fan Cooled (IP ) Alternative Totally Enclosed (IP 0) with Terminal Box (IP ) SD LWS SD LWS SD LWS Voltage, Construction, Connections, Motor Performance s and Optional Extras see pages and for full details. On request gearbox available without feet, can be mounted off of gearbox spigot trapping. Note: mm diameter shaft available with gear ratio s :, :. ( Nm =. lbs. ins.) ( Nm =. cmkp) SD LWS Series/Shunt 00 r.p.m. watts WORM : /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: SPUR : : : : : : : : : : : : : : : 0... SD LWS Series Shunt watts 0.. watts SD LWS Series Shunt watts watts r.p.m. SD LWS Series/Shunt 0 watts SD LWS Series Shunt watts watts SD LWS Series Shunt watts watts WORM SPUR : /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: /: : : : : : : : : : : : : : : :

73 0 holes on 0mm P.C.D. Can be tapped M mm deep. Ø (SD LWS) (SD LWS T.V.) Dimensions in mm. Scale : Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position entry R.H.S. (Not available on SD T.V.). mm dia. h. Keyway mm mm long. Ø.. SD LWS Motor C L..... x. Optional shaft at motor speed (lead end only).mm dia. mm long. holes on 0mm P.C.D. Can be tapped M mm deep. Ø Leads out here cm Dimensions in mm. Scale : Alternative shaft position on request. mm dia. h. Keyway mm mm long. Ø... Approx. weight: SD LWS. Kg Ø SD LWS Motor C L Commutator series/shunt..... x. Leads out here cm Alternative shaft position on request.. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. Optional shaft at motor speed (lead end only).mm dia. mm long. Approx. weight: SD LWS. Kg Dimensions in mm. Scale : SD LWS holes on 0mm P.C.D. Can be tapped M mm deep. Ø. Ø mm dia. h. Keyway mm mm long. Ø. Motor C L..... x. Leads out here cm Alternative shaft position on request.. Optional terminal box tapped 0mm conduit or PG. on request. Shown standard position R.H.S. entry down. Optional shaft at motor speed (lead end only) mm dia. mm long. Approx. weight: SD LWS. Kg

74 Blower Units or Phase Induction Motors Constant Speed 0v DC Shunt and Permanent Magnet Blowers on request Enclosures: SD B Totally Enclosed (IP ) SD BM SD BL Totally Enclosed (IP ) SD B SD BM SD BL SD B SD BM SD BL Voltage Range: 0/v 0/0v. A.C. single phase, 0 Hz. SDB BM BL 0 /0 A.C., three phase, 0 Hz, SD BM SD BL frames only. Special voltages and frequencies, D.C. supply etc. quoted on request. Motor Type: Single phase SD B shaded pole SD BM SD BL capacitor. Suitable for directonline starting. Bearings: Shielded ball bearings, spring loaded for quiet running. Unit suitable for mounting in any position. Casing: Cast aluminium r.p.m. SD B INCHES/W.g. CU./FT./MIN. Cm/Ws CU./METRES/MIN. 0v A.C. phase 0 Hz 0. Amp 0 watts 0v A.C. phase 0 Hz 0. Amp watts Starting current approx. FL current SD BM 0v A.C. phase 0 Hz 0. Amp watts 0v A.C. phase 0 Hz 0. Amp 0 watts Starting current approx. FL current SD BL 0v A.C. phase 0 Hz. Amp 0 watts 0v A.C. phase 0 Hz.0 Amp watts Starting current approx. FL current SD B INCHES/W.g INCHES/W.g A CU./FT./MIN. CU./FT./MIN Cm/Ws Cm/Ws Capacitor for single phase units only CU./METRES/MIN CU./METRES/MIN A Impeller: Steel rustproofed. Connections: SD BM SD BL terminal box, SD B 0mm P.V.C. flexible. Weight: SD B. kg; SD BM. kg; SD BL kg. Note: 00/00 r.p.m. is standard and will be supplied unless otherwise specified. Important: Motor rotation must be set to give anticlockwise direction, as arrow on casting. SD B 0v A.C. phase 0 Hz 0. Amp watts 0v A.C. phase 0 Hz 0. Amp watts Starting current approx. FL current SD BM 0v A.C. phase 0 Hz 0. Amp watts 0v A.C. phase 0 Hz 0. Amp watts Starting current approx. FL current SD BL 0v A.C. phase 0 Hz 0. Amp watts 0v A.C. phase 0 Hz 0. Amp watts Starting current approx. FL current r.p.m. INCHES/W.g INCHES/W.g INCHES/W.g Tapped 0mm conduit or PG. on request. CU./FT./MIN. 0 CU./FT./MIN. 0 0 CU./FT./MIN. 0 0 Cm/Ws Cm/Ws Cm/Ws Capacitor for single phase units only. CU./METRES/MIN CU./METRES/MIN CU./METRES/MIN SD BM SD BL Blowers D U B T B T R M C L I G Leads out here cm D U C Dimples.mm dia. C U D E F H Dimples.mm dia. C U D E I F H G Removable plastic grill. N J P O Q K S Dimensions (mm) A B C D E F G H I J K L M N O P Q R S T U SD B N.T.S SD BM N.T.S SD BL N.T.S....

75 Shaft and Worm Gear Box Positions Single Shaft Y standard Z Shaft optional on request. Double Shaft extensions Y and Z available at extra cost. S, M and L Boxes Standard Position Y Single Reduction MB and LB Box Position only Y MB/MF and LB/LF Boxes Standard Position Y Y Y Z Y Z Z Z A Double Reduction SS and MM Boxes MBM Box Positions C, G, S and W only. MBM Box Standard Position AY Position I to X Single Shaft (Y) facing forward unless otherwise specified Standard Position GY Y B C Y D Y Z E Y F Z Y Z Z Z Y Z G Y H Y Z I J K L Z M N O P Q R S T U V W X All the above positions correspond to the end elevation drawing of the appropriate unit with feet at the base of drawing. Shaft Positions Worm and Multi Spur Gear Box Single Shaft Y standard Z Shaft optional on request. Double Shaft extensions Y and Z available at extra cost Standard position Y. Y Z Lower position Y. Y Z General Information

76 Dimensions of Mounting Flanges for M and L Boxes Details of small, medium and large Worm Gear Boxes Dimensions in mm. Scale : M Box Mounting Flange. holes on 0mm P.C.D. tapped M. Ø 0 Ø mm dia. h. Keyway mm mm long. Approx. weight: 0.0 Kg Dimensions in mm. Scale : L Box Mounting Flange holes on mm P.C.D. tapped M. Ø Ø mm dia. h. Keyway mm mm long. Approx. weight: 0. Kg Dimensions in mm. Scale : Gear Box details for S, M, MB, L, LB, LH LHB A B C D E F S Box holes each side in this position equispaced on.mm P.C.D. Cast.mm dia. suitable for taptite screws. Can be tapped M mm deep on request. M Box holes each side in this position equispaced on.mm P.C.D. Cast.mm dia. Suitable for taptite screws. Can be tapped M mm deep on request. L Box holes each side in this position equispaced on.mm P.C.D. Cast.mm dia. Suitable for taptite screws. Can be tapped M mm deep on request. Optional mm stud fixing (details on request). LH/LHB Box holes each side in this position equispaced on 0mm P.C.D. Cast.mm dia. Can be tapped M mm deep on request. Optional mm stud fixing (details on request). LH/LHB Box Shaft dimension mm O/D mm I/D.mm long with mm internal keyway. Alternatively mm Ø solid shaft available on request in Y, Z, or YZ format. NOMINAL AS CAST DIMENSIONS ± 0.mm Reducteur Gear Box Type type A B C D E F G Ø Ø Ø G G S M L.... LH....

77 Nondrive end Mounting Hole details for Commutator Motors holes Ø./..mm DP. Equally spaced on. P.C.D. SD SD holes Ø./. on. P.C.D. Used for attaching inspection cover and brake plate. holes Ø././0. on. P.C.D. Used for attaching inspection cover. holes Ø../.. DP (through) on. P.C.D.. holes Ø./. 0.. deep. Equally spaced on. P.C.D. Earth screw hole Ø./." through. Earth screw hole Ø./. through. holes Ø./.mm on. P.C.D. Used for attaching inspection cover. SD holes Ø./.. DP (through) on. P.C.D. Tacho and Brake Fixing Details holes (C) Ø./.. Equispaced on mm P.C.D. For tacho attachment on SD, SD, SD, PM and PM 0/0. holes (B) tapped M. Equispaced on mm P.C.D. For Binder brake attachment on SD, SD, SD. PM and PM 0/0. A C B S Brake Flange holes (A) tapped M. Equispaced on 0.mm P.C.D. For Warner brake attachment on SD, SD, SD, PM and PM 0/0.. Thickness mm B. C B A Earth screw hole./. through. mm Nondrive end Mounting Hole details for Permanent Magnet Motors Blind hole./. for earth screw if fitted internally...0 Earth tag attachment point. holes Ø./. on P.C.D. holes Ø./. on P.C.D. Used for attaching inspection cover. Holes Ø./. on. P.C.D. Used for attaching inspection cover and brake flange. " PM PM PM 00 " Earth tag attachment point. Holes Ø./. on P.C.D. General Information

78 Controllers mm 0mm mm mm mm mm CABLE ENTRIES mm (including fixing lip) CABLE ENTRIES 0mm (including fixing lip) CABLE ENTRIES mm (including fixing lip) Boxed Controllers Boxed Controller 00B Boxed Controller Controller Type B B 00B Volts Input } 00/0V A.C. 0/0Hz 00/0V A.C. 0/0Hz V or V via battery } /V A.C. 0/0Hz 0V A.C. via transformer/rectifier Volts Output V D.C. 0V D.C. or 0V D.C. Motor Volts/speed Output 000rpm 00V 000rpm V/V D.C. Motor Types Shunt/Permanent Magnet Motors Shunt/Permenent Magnet Motors All Permanent Magnet Motors/shunt Max (Arm) Current.A Continuous A Output Watts (max) W W 0W Enclosure IP (boxed) IP (boxed) IP (boxed) Form Factor.0 Soft Start Yes Yes Yes Integral Choke (boxed) Yes Yes Weight Boxed.Kg.Kg.Kg Connections Way terminal box way terminal block way connection block Speed Range 0: General Information for Commutator and Permanent Magnet Motor Controllers All wiring diagrams are supplied with the controllers. (for additional information contact our sales engineers). Supply, motor and enclosure must be earthed. All connections are live with respect to supply). Do not instantaneously reverse the motors. They must be allowed to come to rest. Maximum ambient temperature C. 0% Speed Control. % acceleration torque. Practical Information The controllers have a soft start and adjustable current (torque) limit combined with load compensation to give excellent speed/torque characteristics. When a choke is supplied separately it is imperative that it is incorporated into the motor and application to avoid unnecessary commutator damage and excessive brush wear. Where a choke is supplied and not used this may invalidate the warranty.

79 0 Inverter mounting holes mm diameter on mm CABLE ENTRY WATTS INVERTER VARIABLE FREQUENCY INDUCTION MOTOR DRIVE Input: V AC Phase, Output: w. amp Trip: switch off until trip light is off Trip Isolate from supply before removing cover PARVALUX ELECTRIC MOTOR LTD WALLISDOWN, BOURNEMOUTH ENGLAND 0 Induction Motor Variable Speed Drive Tachogenerator (T) A.C. Single Phase 0 The 0 series of phase Induction Motor Drives offers the latest technology for reliable control of squirrel cage induction motors. Operated from a singlephase supply the microprocessorcontrolled drive generates full phase PWM output from smooth speed and torque control at up to twice synchronous speed. Fast monitoring of both current and voltage protect the drive and motor against fault conditions. Speed is controlled from a single potentiometer or voltage source and directional control can be implemented with either push buttons or toggle switch depending on your application. 0 Panel 0 Box (IP) Motor up to 0.Kw Single phase input Three phase output Microprocessor controlled IGBT power stage Earth fault protected Reversing Dc braking on powerup 0 to 0/Hz output Based speed selector 0/0Hz Fan Law selector 00% overload for min EMC filtered Output filtered CE compliant Power rating Watts Input voltage V ac Input frequency Hz Input current.0a Output voltage 0 V ac nom Output frequency Hz Output current.a PWM frequency khz Ambient temp 0 Weight Boxed.Kg Technical Data VOLTS FREQUENCY A.C. (Hz) 0 Hz Dimensions in mm TACHOGENERATOR T Ø Nominal output A.C. Voltage: V per 0 r.p.m. 0 0 Hz ctrs Output frequency: 00Hz per 0 r.p.m. (approx.) 00 Hz Maximum speed: 000 r.p.m. 00 Hz Ø 0 Internal resistance: Hz Minimum external resistance: k per 0 r.p.m. Tacho cannot be fitted to TEFC or brake units. 00 Hz SPEED N.B.: Flange not required for PM, PM. Leads 00mm long. Generator Skeleton Controller for Brushless Motor BLI Boxed controll available on request. Volts input V dc Volts output V dc Amps A Speed variation Control voltage 0 V dc via Potentiometer or a dc input Adjustment available for high and low speed settings Torque limiter

contents about the range

contents about the range contents Overview 3 Motor data PBL42 4 PBL60 5 PBL86 6 Technical information 7 Controller data S controller 9 N and B controllers 10 50B controller 12 EMC Directive compliance 13 Geared motors PBL42 motor

More information

Product overview visit for more details

Product overview visit  for more details Product overview visit www.parvalux.com for more details DC brushless (PBL) DC permanent magnet (PM) AC induction (SD) motors only Type Code Shaft Orientation Power (Watts)* Speed (rpm) Torque (Nm)** Power

More information

SUB-FHP AC GEARMOTORS PARALLEL SHAFT GEARMOTORS

SUB-FHP AC GEARMOTORS PARALLEL SHAFT GEARMOTORS SUB-FHP AC GEARMOTORS PARALLEL SHAFT GEARMOTORS 12-100 In-Lbs Single phase gearmotors, totally enclosed for continuous duty, general purpose applications. Permanent TEFC split capacitor designs are rated

More information

SINGLE PHASE TEFC CAGE MOTORS

SINGLE PHASE TEFC CAGE MOTORS SINGLE PHASE TEFC CAGE MOTORS 2 SINGLE PHASE TEF CAGE MOTORS Mechanical protection: IP 54 Voltage: 220 V, 50 Hz Type Output power P N kw Rated speed n N min -1 Efficiency % Power factor cos Rated current

More information

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE   Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT TECHNOLOGIES ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT Enjoy the peace of mind ESS-ESD PRODUCT CATALOGUE CORE VALUES PEACE OF MIND EFFICIENCY FAIRNESS RESPONSIBILITY CUSTOMER ORIENTATION GROWING DEVELOPED

More information

CUSTOM DC MOTORS & GEARMOTORS

CUSTOM DC MOTORS & GEARMOTORS & GEARMOTORS Battery-powered, 24-volt motor with close coupled hydraulic pump mounting on one end and standard NEMA 56 C face and shaft on other end. Totally enclosed fan cooled, thyristor rated, partial

More information

SERIES 12 SUB-FHP RIGHT ANGLE DC GEARMOTORS

SERIES 12 SUB-FHP RIGHT ANGLE DC GEARMOTORS SERIES 12 SUB-FHP RIGHT ANGLE DC GEARMOTORS SERIES 12 SUB-FHP Electrical Specifications: Both SCR (90 volt) and Low Voltage (12 volt) right angle gearmotors. the 90 volt motors are performance matched

More information

Open continuous current (DC) motors MS 1 - MS 2. General information

Open continuous current (DC) motors MS 1 - MS 2. General information MS 1 - MS 2 General information Open continuous current (dc) motors conforming to the IEC specifications. MS 1 : - frame size 80 to 132 mm, - power 0.44 to 8.85 kw. MS 2 : - frame size 112 and 132 mm,

More information

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors 1. What are the two main parts of a three-phase motor? Stator and Rotor 2. Which part of a three-phase squirrel-cage induction motor is a

More information

QUICK REFERENCE Stock Sub-FHP Gearmotors

QUICK REFERENCE Stock Sub-FHP Gearmotors Parallel Shaft PZ Series QUICK REFERENCE Stock Sub-FHP P240 & P300 Series AC Single & Three Phase Single Phase 115V 12-100 In-Lbs Page 102 Single Phase 115/230V 43-391 In-Lbs Page 103 DC SCR & Low Voltage

More information

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES TABLE OF CONTENTS Motor Information Guide Definitions And Abbreviations... page 2 Motor Identification Without A Nameplate What To Look For... page 3 Direct Drive Blower Motors: Two Speed... page 4 Three

More information

Technical description... 1 Limit switch versions MR 6 Power tables... 6 Dimensions... 7 Spare part lists... 8

Technical description... 1 Limit switch versions MR 6 Power tables... 6 Dimensions... 7 Spare part lists... 8 Index Technical description... 1 Limit switch versions... 3 MR 6 Power tables... 6 Dimensions... 7 Spare part lists... 8 MS 12 Power tables... 10 Dimensions... 11 Spare part lists... 13 MR 30 Power tables...

More information

SECTION MOTOR REQUIREMENTS for HVAC

SECTION MOTOR REQUIREMENTS for HVAC PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life

More information

QUICK REFERENCE Stock Sub-FHP Gearmotors

QUICK REFERENCE Stock Sub-FHP Gearmotors QUICK REFERENCE Stock Sub-FHP Right-Angle Worm Type 10 & 13 Series AC Single & Three Phase Single Phase 115/230V 14-113 In-Lbs Page 155 DC SCR & Low Voltage DC SCR 90 & 180V 5-135 In-Lbs Low Voltage (12V)

More information

Series E4F E5F

Series E4F E5F Three Phase Induction Motors With Rotors Wound for Hoists Series E4F 160-315 E5F 355-400 ASI NT 003.1 I N D E X Use 2 Electrical Tolerances 9 Mechanical Tolerances 9 General Characteristics 2 Technical

More information

MT30R4 D.C. Servomotors

MT30R4 D.C. Servomotors MT30R4 D.C. Servomotors Technical Data Parameter Unit MT30R4-58 MT30R4-46 MT30R4-37 MT30R4-25 GENERAL Voltage Gradient No Load Volts/1000RPM* 58 46 37 25 Max. Terminal Voltage Volts 140 140 140 100 Max.

More information

Parvalux. DC Brushless Catalogue

Parvalux. DC Brushless Catalogue Parvalux DC Brushless Catalogue our technology Our motor technologies span from AC induction through to DC brushless and our gearbox know-how covers practically all types from spur/helical through to worm

More information

CUSTOM DC MOTORS & GEARMOTORS

CUSTOM DC MOTORS & GEARMOTORS & GEARMOTORS Battery-powered, 24-volt motor with close coupled hydraulic pump mounting on one end and standard NEMA 56 C face and shaft on other end. Totally enclosed fan cooled, SCR rated, partial motor

More information

Primary Brake Spline Drive Armature PB-825, PB-1000, PB-1225, PB-1525

Primary Brake Spline Drive Armature PB-825, PB-1000, PB-1225, PB-1525 Primary Brake Spline Drive Armature PB-825, PB-1000, PB-1225, PB-1525 P-209-WE 819-0517 Installation Instructions Contents Installation Instructions PB-825 PB-1000 PB-1225 PB-1525... 3 Coil Data... 5 Burnishing

More information

Application Information

Application Information Moog Components Group manufactures a comprehensive line of brush-type and brushless motors, as well as brushless controllers. The purpose of this document is to provide a guide for the selection and application

More information

Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors

Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors 1. What are the two main parts of a three-phase 2. Which part of a three-phase squirrel-cage induction motor is a hollow core? 3. What are

More information

Energy Saving Three Phase Motors

Energy Saving Three Phase Motors e-drive Energy Saving Three Phase Motors IEC frames 56 to 400 Outputs 0.09 to 630 IE2 MEPS2006 Type: AHE Aluminium Motors Type: HE Cast-Iron Motors 1 When you need all the features of a premium quality

More information

DC motors. G-motion. CTi Automation - Phone: Fax: Web:

DC motors. G-motion. CTi Automation - Phone: Fax: Web: G-motion No matter which drive solution you imagine, we make your dreams come true. True to our slogan (one stop shopping) we offer you a complete programme of electronic and mechanical drive systems which

More information

Preassembled Clutch/Brake Module

Preassembled Clutch/Brake Module Preassembled Clutch/Brake Module P-273-1-WE 819-0343 Installation Instructions An Altra Industrial Motion Company Contents MountingtoaMotor...3 Mounting to a Reducer.............3 Installing the Base Mount...........4

More information

MADE IN U.S.A. Inverter Grade Magnet Wire. Fan Cooled for High Output Power. Selectively hardened all steel gears

MADE IN U.S.A. Inverter Grade Magnet Wire. Fan Cooled for High Output Power. Selectively hardened all steel gears Bodine Electric s extensive line of stock 3-phase, inverter duty, induction motors and gearmotors was designed with your application needs in mind. Bodine offers the widest selection of inverter duty,

More information

Chapter 3.2: Electric Motors

Chapter 3.2: Electric Motors Part I: Objective type questions and answers Chapter 3.2: Electric Motors 1. The synchronous speed of a motor with 6 poles and operating at 50 Hz frequency is. a) 1500 b) 1000 c) 3000 d) 750 2. The efficiency

More information

IP66 GSW GEAR BOX MOTOR SERIES

IP66 GSW GEAR BOX MOTOR SERIES IP66 GSW GEAR BOX MOTOR SERIES Three Phase Aluminium Gear Box Motors Australian Version October 2013 CONTENTS INTRODUCTION Pg 3 MATERIALS AND CONSTRUCTION Pg 3-4 SERIES OVERVIEW Pg 5 PERFORMANCE DATA Pg

More information

ADI-125/750 ADI-125/1500 ADI-125/2500

ADI-125/750 ADI-125/1500 ADI-125/2500 Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121094B OWNERS

More information

TB Series Brakes Tension Control System

TB Series Brakes Tension Control System TB Series Brakes Tension Control System P-235-WE Service & Installation Instructions An Altra Industrial Motion Company Contents Installation Instructions...3 Coil Data...4 Maintenance...5 Control Connections...5

More information

Filtered PWM Speed Control for Permanent Magnet DC Motors

Filtered PWM Speed Control for Permanent Magnet DC Motors Instructions for Installation and Operation Filtered PWM Speed Control for Permanent Magnet DC Motors Model 0794 Speed and Direction Control up to 5/8 HP NEMA-1/IP-20 Specifications Product Type:... WPM-2148E1

More information

Hydraulic Fittings. Design, Manufacture, Distribution

Hydraulic Fittings. Design, Manufacture, Distribution Hydraulic Fittings Design, Manufacture, Distribution Hydraulic Fittings are exclusively distributed by Beaumanor Engineering Ltd of Leicester and manufactured by Balu Auto Components of Chennai India,

More information

MADE IN U.S.A. Inverter Grade Magnet Wire. Fan Cooled for High Output Power. Selectively hardened all steel gears

MADE IN U.S.A. Inverter Grade Magnet Wire. Fan Cooled for High Output Power. Selectively hardened all steel gears Variable speed, inverter duty, threephase motors and gearmotors with matched AC controls Permanent split capacitor motors are reliable, easy to install and ideal for fixed speed applications The best solution

More information

INTRODUCTION GENERAL GUIDELINES ATTACHING THE DRIVE PARTS

INTRODUCTION GENERAL GUIDELINES ATTACHING THE DRIVE PARTS INTRODUCTION Kretzschmar DC motors are of substantialy designed and manufactured to high standards. These motors will work satisfactorily for many years as long as they are maintained following the instructions.

More information

VEM motors Thurm GmbH

VEM motors Thurm GmbH VEM motors Thurm GmbH Installation, Operating and Maintenance Instructions Single-Phase Squirrel-Cage Induction Motors, Standard Version March 2005 1. General To avoid damage to the motors and equipment

More information

1LG0 Low-voltage Motors

1LG0 Low-voltage Motors Low-voltage motors up to 315kW Catalog D81.5.1 1LG Low-voltage Motors Answers for industry. 1 Table of Contents Overview 3 Motor standards 5 Mechanical design 6 Electrical design 1 Converter fed application

More information

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 1. APPLICATION A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 2. REFERENCE STANDARDS A. The transformers supplied shall

More information

Electro-Brake 375, 475, 650, 825, 1000, 1225

Electro-Brake 375, 475, 650, 825, 1000, 1225 Electro-Brake 375, 475, 650, 825, 1000, 1225 P-211-WE 819-0043 Installation Instructions An Altra Industrial Motion Company Contents Installation Instructions.... 2 Electrical Coil Data.... 5 Burnishing

More information

Proven technology for individual valve solutions worldwide. GWC Valve International

Proven technology for individual valve solutions worldwide. GWC Valve International Proven technology for individual valve solutions worldwide FORGED STEEL VALVES GATE, GLOBE & CHECK PRESSURE CLASS: ASME 150-2500 SIZE RANGE: 1/4-3 API STANDARD: 602 ASME B16.34 Catal og Nu mb er f SV-

More information

QUICK REFERENCE Stock Sub-FHP Gearmotors

QUICK REFERENCE Stock Sub-FHP Gearmotors QUICK REFERENCE Stock Sub-FHP AC Single & Three Phase DC SCR & Low Voltage Parallel Shaft PZ Series Single Phase 115V 12-100 In-Lbs Page 166 DC SCR 90 & 180V 10-100 In-Lbs 36-100 In-Lbs torque Page 156

More information

MINA-GEAR GEARMOTORS P-1. Mina-Gear Features... P-2 Application & Selection... P-3 Right-Angle Worm Gearmotors Series Parallel Shaft Gearmotors

MINA-GEAR GEARMOTORS P-1. Mina-Gear Features... P-2 Application & Selection... P-3 Right-Angle Worm Gearmotors Series Parallel Shaft Gearmotors MINA-GEAR GEARMOTORS Mina-Gear..................................................... -2 Application & Selection................................................... -3 Right-Angle Worm Gearmotors 2100 Series

More information

PAC TRAINING PUMP MOTORS

PAC TRAINING PUMP MOTORS PAC TRAINING PUMP MOTORS 1 Basics Magnet supported from above N S N S Since unlike poles repel each other, the magnet will rotate Stationary Magnet 2 Basics N S Stationary Magnet 3 Basics N N S S Stationary

More information

"Motors, Power, and Data Loggers Greg Jourdan-Wenatchee Valley College Carol Lewellen-NEEC and BOC Tuesday, May 8, Sessions Session

Motors, Power, and Data Loggers Greg Jourdan-Wenatchee Valley College Carol Lewellen-NEEC and BOC Tuesday, May 8, Sessions Session "Motors, Power, and Data Loggers Greg Jourdan-Wenatchee Valley College Carol Lewellen-EEC and BOC Tuesday, May 8, 2018 3 Sessions Session 1-8:30-9:25 a.m. Motors 101 Session 2-9:30-10:25 a.m. - Power Session

More information

OM DC Motors Series. Ⅱ. Item Define Example:

OM DC Motors Series. Ⅱ. Item Define Example: OM DC Motors Series Ⅰ.Features and Uses OM DC motors Series are new developed products. The products have found wide use for prime mover in various machinery, such as mill auxiliary in metallurgical industry,

More information

Watertight, Dust-Resistant. Motors. Standard AC Motors A-207. Standard AC Motors Intro duction. Motors. AC Speed Control Motors Inverter.

Watertight, Dust-Resistant. Motors. Standard AC Motors A-207. Standard AC Motors Intro duction. Motors. AC Speed Control Motors Inverter. Standard AC Standard AC Intro duction Induction Reversible Electromagnetic Brake Right-Angle Gearheads SB5W US ES2 FE1/FE2 AC Speed Control Inverter Torque Accessories Installation A-27 Standard AC RoHS-Compliant

More information

P-286 (WC-58/59) Wichita Clutch. Service & Installation Instructions

P-286 (WC-58/59) Wichita Clutch. Service & Installation Instructions P-286 (WC-58/59) Wichita Clutch Standard Ventilated Clutch Special Ventilated Clutch Service & Installation Instructions Contents Installation...2 W1 Shaft to Shaft Mounting...2 W2 Mid-Shaft Mounting...3

More information

Modifiable TITAN Horizontal Motors Accessories and Modifications

Modifiable TITAN Horizontal Motors Accessories and Modifications 36. Rotor, Standard And Optional Construction Standard rotor construction of 449, 5000 and 5800 frame TITAN products is typically die-cast aluminum. 720 RPM and slower is typically fabricated aluminum.

More information

Electromagnetic Toothed Clutch E330

Electromagnetic Toothed Clutch E330 P-2041-WE SM310-gb-11/04 Electromagnetic Toothed Clutch E330 Service Manual We: WARNER ELECTRIC EUROPE, 7, rue Champfleur, B.P. 20095, F-49182 St Barthélemy d Anjou Cedex declare that the clutches made

More information

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls P-269-89-0408 Installation Installation & Operating Instructions Contents Introduction........................... 2 Specifications.........................

More information

C-SERIES S-SERIES. Metric Machine Screw Jacks EMA LINEAR ACTUATORS

C-SERIES S-SERIES. Metric Machine Screw Jacks EMA LINEAR ACTUATORS C-SERIES S-SERIES Metric Machine Screw Jacks EMA LINEAR ACTUATORS Power Jacks has a proud engineering heritage dating from the earliest years of the 20th Century. A heritage that is about excellence: about

More information

F O R M. Installation and Maintenance Manual for FCR Equipped Motors and Gearmotors. 9055E Revised October 2015

F O R M. Installation and Maintenance Manual for FCR Equipped Motors and Gearmotors. 9055E Revised October 2015 Installation and Maintenance Manual for FCR Equipped Motors and Gearmotors Power Transmission Solutions Regal Beloit America, Inc. 7120 New Buffington Road Florence, KY 41042 Application Engineering: 800

More information

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1 AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1 STANDARD AND SPECIFICATION Performance: Meet the requirement of Singapore standard

More information

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev MORATTO S.R.L. Electrical Machinery I 31030 PERO DI BREDA (Treviso) Italy Via A Volta, 2 Tel. +390422904032 fax +39042290363 www. moratto.it - moratto@moratto.it THREE PHASE AND SINGLE PHASE ASYNCHRONOUS

More information

FCR asynchronous brake motors LS FCR. General information

FCR asynchronous brake motors LS FCR. General information General information LIFTING USE : U.L. Enclosed three-phase asynchronous brake motors, LS series with failsafe brake, according to IEC 34, 72, EN 50281. Single speed : 0.55 to 15, frame size from 80 to

More information

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 120015D OWNERS

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S Revised 04/14/2016 SPECIFICATIONS - DETAILED PROVISIONS Section 16151 - Vertical Hollowshaft Electric Motors C O N T E N T S PART 1 - GENERAL... 1 1.01 SCOPE... 1 1.02 SPECIFIC PROJECT REQUIREMENTS...

More information

50 Hz Mini/Micro Computer Regulator (MCR) Series Installation and Operation Manual

50 Hz Mini/Micro Computer Regulator (MCR) Series Installation and Operation Manual Operating & Service Instructions Sola Minicomputer Regulators UL White Card Listed Power Supply Classification CSA Certified Transformer Classification General Description and Specifications The Sola Micro/Minicomputer

More information

PROCESS ELECTRONICS CORPORATION

PROCESS ELECTRONICS CORPORATION MINIVERTER MANUAL PROCESS ELECTRONICS CORPORATION 100 BRICKYARD ROAD MOUNT HOLLY, NORTH CAROLINA 28120 TELEPHONE (800) 421-9107 FAX (704) 827-9595 SALES@PECRECTIFIER.COM WWW.PECRECTIFIER.COM SOLID STATE

More information

TYPE 2 poles 4 poles 6 poles 8 poles 2 / 4 poles 4 / 8 poles 2 / 8 poles 4 / 16 poles

TYPE 2 poles 4 poles 6 poles 8 poles 2 / 4 poles 4 / 8 poles 2 / 8 poles 4 / 16 poles BAH-BAHS series Overwiew MGM Electric Motors was established in 1950 as a brake motors manufacturer. MGM is today a world leading manufacturer of this line of products. MGM brake motors are designed and

More information

Electromagnetic Particle Brakes Model: PRB-H

Electromagnetic Particle Brakes Model: PRB-H P-223-3 819-0370 Electromagnetic Particle Brakes Model: PRB-H Installation Instructions Table of Contents Introduction............................2 Installation Instructions....................3 Start

More information

Lenze. Drives with worm gearboxes 52.

Lenze. Drives with worm gearboxes 52. 6 887 Lenze Drives with worm gearboxes 5. Lenze Drive Systems GmbH, Postfach 0 5, D-76 Hameln, Site: Groß Berkel, Hans-Lenze-Straße, D-855 Aerzen, Phone ++9 (0) 55 8-0, Telefax ++9 (0) 55 8- E-Mail: Lenze@Lenze.de

More information

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR ISSUED October 28, 2013 TYPE AETACF PERFORMANCE DATA 3-PHASE INDUCTION MOTOR ENCLOSURE TEFC CATALOG# GV0/74C NAMEPLATE INFORMATION OUTPUT FRAME RATED INS. POLE VOLTAGE HZ HP KW SIZE AMBIENT CLASS 3/4 0.56

More information

IronHorse MTG DC Gearmotors. IronHorse DC Gearmotors User Manual User Manual Number: IH-MTG-DC-USER-M-WO

IronHorse MTG DC Gearmotors. IronHorse DC Gearmotors User Manual User Manual Number: IH-MTG-DC-USER-M-WO IronHorse DC Gearmotors User Manual User Manual Number: IH-MTG-DC-USER-M-WO Page a BLANK PAGE Page b IronHorse DC Gearmotors User Manual Table of Contents Revision History of This User Manual ii WARNING

More information

GWC Valve International

GWC Valve International GWC Valve International PROVEN TECHNOLOGY FOR INDIVIDUAL VALVE SOLUTIONS WORLDWIDE API 6D SWING CHECK VALVES Pressure Class: ASME 150-2500 Size Range: 2-36 CATALOG NUMBER SC-1001 G W C V A L V E I N T

More information

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual Electronic Motor Brake Type G Instructions and Setup Manual Table of Contents Table of Contents Electronic Motor Brake Type G... 1 1. INTRODUCTION... 2 2. DESCRIPTION AND APPLICATIONS... 2 3. SAFETY NOTES...

More information

Installation Instructions

Installation Instructions Primary Brake Pin Drive Armature PB-825, PB-1000, PB-1225, PB-1525 Motor Brake and Spline Drive MB-825, MB-1000, MB-1225 Pin Drive P-208 819-036 Installation Instructions Contents Installation Instructions

More information

OWNERS MANUAL JANUARY 2007 ISO

OWNERS MANUAL JANUARY 2007 ISO Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121231B OWNERS

More information

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 3009/16 en Ed.02.2016 Read these Operating Instructions before performing any transportation, installation, commissioning, maintenance or

More information

IronHorse MTG DC Gearmotors. IronHorse DC Gearmotors User Manual User Manual Number: IH-MTG-DC_UMW

IronHorse MTG DC Gearmotors. IronHorse DC Gearmotors User Manual User Manual Number: IH-MTG-DC_UMW IronHorse DC Gearmotors User Manual User Manual Number: IH-MTG-DC_UMW Page a BLANK PAGE Page b IronHorse DC Gearmotors User Manual Table of Contents Revision History of This User Manual....................

More information

E180 DIAMETER FRAMES

E180 DIAMETER FRAMES E18 DIAMETER FRAMES MODEL NUMBER CODE...E18 FRAME To construct a motor listing, select the combination of features required and put all the coded information in the proper sequence. Please account for

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com ISO 9001:2000 Certified

More information

Motor Basics AGSM 325 Motors vs Engines

Motor Basics AGSM 325 Motors vs Engines Motor Basics AGSM 325 Motors vs Engines Motors convert electrical energy to mechanical energy. Engines convert chemical energy to mechanical energy. 1 Motors Advantages Low Initial Cost - $/Hp Simple &

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121114C OWNERS

More information

Electromagnetic clutch-brake combinations INTORQ

Electromagnetic clutch-brake combinations INTORQ Electromagnetic clutch-brake combinations INTORQ 14.800 14.867 7.5 120 Nm setting the standard 2 CBC en 5/2005 Contents Clutch-brake combinations Product information 4 Type code 6 Design selection 8 Overview

More information

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11 Please read and observe this Operating Instruction carefully! A possible malfunction or failure of the brake and any damage may be caused by not observing it. Table of contents: Page 1: Page 2: Page 3:

More information

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10 A6C A5C-B6C B5C B5H Model Power Voltages Model IP55 A6C A5C B6C B5C B5H Up to 2.400 kw Up to 11.000 V LV A6C - B6C - A5C - B5C MV B5H Frame 71 560 Pole 2, 4, 6, 8 and 10 Cooling IC 411 ( IC 416 optional)

More information

Ordering information. When placing an order, specify motor type, size and product code according to the following example.

Ordering information. When placing an order, specify motor type, size and product code according to the following example. Ordering information When placing an order, specify motor type, size and product code according to the following example. Example Motor type M3AA 112 MB Pole number 4 Mounting arrangement (IM-code) IM

More information

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual Graham TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual Vari Speed S1000 Instruction Manual TABLE OF CONTENTS Introduction 4 Unit Features 5 Operating Conditions 6 Specifications 7 Ratings

More information

HA/HAB Fiberglass Wall Mount Ventilators

HA/HAB Fiberglass Wall Mount Ventilators HA/HAB Fiberglass Wall Mount Ventilators INSTALLATION, OPERATION & MAINTENANCE MANUAL IM-3100 August 2015 Throughout this manual, there are a number of HAZARD S that must be read and adhered to in order

More information

TERMS AND CONDITIONS OF PARKING AT PALMERSTON NORTH AIRPORT

TERMS AND CONDITIONS OF PARKING AT PALMERSTON NORTH AIRPORT TERMS AND CONDITIONS OF PARKING AT PALMERSTON NORTH AIRPORT 14 December 2017 Palmerston North Airport Limited ( PNAL ) provides travellers and other members of the public with multiple car parking options

More information

12-1/4 x 3-1/2 Electric Wheel Brake

12-1/4 x 3-1/2 Electric Wheel Brake 12-1/4 x 3-1/2 Electric Wheel Brake A-216 819-0244 Installation Instructions An Altra Industrial Motion Company Contents Dimensions.... 2 Technical Specifications.... 3 Installation Instructions General....

More information

Operating Instructions

Operating Instructions Operating Instructions Table of contents Table of contents... 1 1. Declaration... 1 2. Warranty and liability... 2 3. Gear description... 2 4. Gear types... 2 5. Safety... 3 5.1 General safety information...

More information

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02 SELECT DIAGNOSTIC GUIDE INST028 Doc 3.02 CONTENTS General Information...2 Select Call-Outs...3 Wire Diagram and Legend...4 Diagnostics...6 Excessive Voltage Drop Diagnostics...6 Static Diagnostics...7

More information

MICRO SWITCH INSTALLATION SHEET

MICRO SWITCH INSTALLATION SHEET MICRO SWITCH INSTALLATION SHEET Micro Switch Cam Rest Position See Vertical or Horizontal Arm Installation Instructions for Micro Switch activation sequence. Micro Switch Cam Adjustment Screw SW 1 Micro

More information

K1013 K1013. Fitting Instructions for Basic Carrier. x 4 x 4 x 1 x 8. x 4 x 1 x 4 x 1. x 4 x 1 x 1 x 2. Revision No: 1A 1

K1013 K1013. Fitting Instructions for Basic Carrier. x 4 x 4 x 1 x 8. x 4 x 1 x 4 x 1. x 4 x 1 x 1 x 2. Revision No: 1A 1 Fitting Instructions for Basic Carrier x 4 x 4 x 1 x 8 x 4 x 1 x 4 x 1 x 4 x 1 x 1 x 2 Revision No: 1A 1 MAX kgs (lbs) W/P WHD Holden Spark, 5dr Hatch 16-+ AU 50 kgs (110 lbs) 50 kgs (110 lbs) Spark, 5dr

More information

Actol Electric Quarter-turn Valve Actuators

Actol Electric Quarter-turn Valve Actuators Actol Electric Quarter-turn Valve Actuators SMART VALVE CONTROLS MANUFACTURERS OF ELECTRIC ACTUATORS STEAM & CONTROL SYSTEM SPECIALISTS Made in the UK Smart Valve Controls Limited have applied over twenty

More information

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9 Please read the Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to clutch failure, resulting in damage to other parts. Contents:

More information

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company Manufacturer of Dimensions Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com OWNERS MANUAL April

More information

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1) 630-543-7867 Products & Services EQ7 1-1000 hp Intelligent Keypad with Extensive Diagnostics Select Any of 4 Control Methods - V/ Hz - Dynamic Torque - Sensorless Vector - Closed-loop Vector Quick Setup

More information

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls CBC-300 & CBC-300- Series Dual Channel Adjust Clutch/Brake Controls P-205-WE 89-0549 Installation & Operating Instructions An Altra Industrial Motion Company Contents Introduction... 2 Specifications...

More information

Pretest Module 21 Unit 4 Single-Phase Motors

Pretest Module 21 Unit 4 Single-Phase Motors Pretest Module 21 Unit 4 Single-Phase Motors 1. What are the four main components of a single-phase motor? Rotor, stator, centrifugal switch, end bells and bearings 2. How is a rotating field created in

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS. Frames 143T - 449T

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS. Frames 143T - 449T INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449T RECEIVING 1. Check nameplate data. 2. Check whether any damage has occurred during transportation. 3. After

More information

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB P-273-8 819-0531 Installation Instructions Vented Enclosed Version Optional An Altra Industrial Motion Company Warner Electric s

More information

Contents INTRODUCTION... 2 CHECK YOU HAVE RECEIVED... 4 WHAT YOU WILL NEED...4 TECHNICAL CHARACTERISTICS...5 WIRING DIAGRAMES...6 CABLES...

Contents INTRODUCTION... 2 CHECK YOU HAVE RECEIVED... 4 WHAT YOU WILL NEED...4 TECHNICAL CHARACTERISTICS...5 WIRING DIAGRAMES...6 CABLES... Contents Page INTRODUCTION... 2 CHECK YOU HAVE RECEIVED... 4 WHAT YOU WILL NEED...4 TECHNICAL CHARACTERISTICS...5 WIRING DIAGRAMES...6 CABLES...6 BATTERY...7 CHARGE CONTROLLER...8 FUSE...8 TOWERS...8 INSTALLATIONS...9

More information

MIL-24/2600Q MIL-24/3200DQ

MIL-24/2600Q MIL-24/3200DQ Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121473B OWNER'S

More information

RGZESDI Inverter Duty AC Induction Motors

RGZESDI Inverter Duty AC Induction Motors November 1999 RGZESDI Inverter Duty AC Induction Motors Installation Operation Maintenance Instructions Frames: 143T through S449SS/LS SIGNAL WORDS The signal words Danger, Warning and Caution used in

More information

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L. REDI-LINE ELECTRIC GENERATORS USER'S GUIDE Rugged, Reliable, DC to AC Power Conversion KARAM A.L. www.alternatorstarter.com 1-888-515-2726 REDI-LINE ELECTRIC GENERATOR MODEL INPUT ACTUAL OUTPUT ACTUAL

More information

Explosion and flame-proof cast iron electric motors

Explosion and flame-proof cast iron electric motors Explosion and flame-proof cast iron electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 160 3 phases Voltage 230/400 V 50Hz Voltage 265/460V 60Hz Types of mounting

More information

900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX

900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX 900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX Read and understand the pump and motor instructions before attempting to install, disassemble or repair the pump. Part # AF-03-326 2015 Pentair Ltd. 01/30/15

More information

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm 95 Nm to 2900 Nm Introduction The range of IP23 protection CPLS asynchronous motors was designed for fixed and variable speed applications when there is little space available or (and) there is a wide

More information

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand. Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors A Regal Brand www.regalbeloit.com Specifications Range Poles Voltage : Upto 3000 KW : Upto 14 Pole : Upto 11000 Volt Frame : 450 1000

More information