2

3

4

5

6 国家级仪器仪表防爆安全监督检验站 National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation (GYJ X) (Attachment I) AttachmentⅠ (Translation) Solenoid type 11A52, 11C52, 11E52 and 11F52 series, manufactured by Eugen Seitz AG, have been approved by National Supervision and Inspection Center for Explosion Protection and Safety of Instrumentation (NEPSI) in accordance with the following standards: GB Explosive atmospheres Part 1: Equipment General requirements GB Explosive atmospheres Part 3: Equipment protection by increased safety e GB Electrical apparatus for explosive gas atmospheres Part 9: Encapsulation m GB Electrical apparatus for use in the presence of combustible dust Part 1-1:Electrical apparatus protected by enclosures and surface temperature limitation Specification for apparatus The solenoid is approved with explosion marking of Ex embⅡt5/t6 Gb or DIP A21 T A,T5/T6, IP code is IP65, the certificate number is GYJ X. The correlations between type, marking, permissible maximum ambient temperature range and rated value are as below: Type 11A52 Temperatue class T5 T6 T5 Tamb. -20 ~ ~ ~+40 Rated voltage 6 V~400 V d.c. Rated current 6mA~430mA 6mA~430mA 12mA~900mA Maximum rated power 2.5W 2.5W 5.0W Type 11C52 Temperatue class T5 T6 Tamb. -20 ~ ~+50 Rated voltage 6 V~400 V a.c. / 48 Hz~62 Hz Rated current 10mA~700mA Maximum rated power 4.0VA Page 1 of 3

7 (GYJ X) (Attachment I) Type 11E52 Temperatue class T5 T6 Tamb. -20 ~ ~+50 Rated voltage 6 V~400 V d.c. Rated current 6mA~430mA Maximum rated power 2.5W Type 11F52 Temperatue class T5 T6 T5 Tamb. -20 ~ ~ ~+40 Rated voltage 6 V~400 V d.c. 或 6 V~400 V a.c. / 48 Hz~62 Hz Rated current 6mA~430mA 6mA~430mA 12mA~900mA Maximum rated power 2.5W/VA 2.5W/VA 5.0W/VA 1. SPECIAL CONDITIONS FOR SAFE USE 1.1 A fuse corresponding to the rated current of the magnet (max.3 I B ) or a motor protecting switch with short-circuit or thermal instantaneous tripping (adjusted to rated current) must be connected in series to each magnet. The rated voltage of the protecting component shall be the same as or higher than the rated voltage specified for the magnet. The breaking capacity of the fuse link shall be the same as or higher than 1500A. 1.2 The way of installation has to guarantee the maximum surface temperature of solenoid could not exceed the requirements of the temperature classification. 1.3 During installation, use and maintenance the solenoid, any friction, cleaned with dry cloth or solvent should be prevented in order to avoid the risk of electrostatic. 2. SPECIAL REQUIREMENTS 2.1 The internal and external earthing terminal should be connected to the ground reliably at site. 2.2 The temperature of media, measured by the valve, which includes the solenoids to this certificate, could not exceed the requirements of the ambient temperature. 2.3 The enclosure of the solenoid shall be kept from the dust, but the dust shall not be blown by compressed air. 2.4 The cable entry holes have to be connected by means of suitable cable entry device, the way of being installed shall be ensure that the solenoid satisfies degree of protection IP Forbid user to change the configuration to ensure the equipment s explosion protection performance. Whatever should be done only by experts from the manufacturer. Page 2 of 3

8 (GYJ X) (Attachment I) 2.6 During installation, operation and maintenance, users shall comply with the relevant requirements of the product instruction manual, GB "Electrical apparatus for explosive gas atmospheres Part 13: Repair and overhaul for apparatus used in explosive gas atmospheres", GB "Electrical apparatus for explosive gas atmospheres Part 15: Electrical installations in hazardous areas (other than mines)", GB "Electrical apparatus for explosive gas atmospheres Part 16: Inspection and maintenance of electrical installation (other than mines)", GB "Safety regulations for the protection of dust explosion", GB "Electrical apparatus for use in the presence of combustible dust - Part 2: Selection and installation" and GB "Code for construction and acceptance of electric device for explosion atmospheres and fire hazard electrical equipment installation engineering". 3. MANUFACTURER S RESPONSIBILITY 3.1 The instruction manual should include all the items mentioned above. 3.2 The manufacturer must strictly produce according to the documents approved by NEPSI. 3.3 The following contents are added to the nameplate of the solenoid: Identification of NEPSI Certificate No. GYJ X National Supervision and Inspection Center For Explosion Protection and Safety of Instrumentation Sep. 16, 2012 Page 3 of 3

国家级仪器仪表防爆安全监督检验站 National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation (GYJ12.1232X) (Attachment I) AttachmentⅠ (Translation) Solenoid type 2A52W and 2C52W series,

More information

Solenoid Operator 0516 / 1216

Solenoid Operator 0516 / 1216 nass magnet GmbH Edition no. 2 Eckenerstraße 4-6 2007-01-10 D-30179 Hannover Rev.2 070110 Solenoid Operator 0516 / 1216 Operating Instructions NN 8220 126 and EC Declaration of Conformity Dear Customer!

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

Solenoid Operator 0513 / 1213

Solenoid Operator 0513 / 1213 nass magnet GmbH Run Nr. 5 Eckenerstraße 4-6 24.10.2006 D-30179 Hannover Rev. 5 061024 Solenoid Operator 0513 / 1213 Operating Instructions NN 8220 112 and EC Declaration of Conformity Dear Customer! In

More information

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5). EVI 7 S9 Solenoid System The EVI7 S9 system by AMISCO includes a wide range of solenoids, coils and operators, designed for pneumatic valves. All solenoids of this system have the guide tube with a diameter

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Explosion proof electric motor For Fuel dispensing application. Main characteristic Ad-pe ed.2018/0 1 Explosion proof electric motor For Fuel dispensing application RAEL motori elettrici, since its inception in the late 60s, has assembled more than a million of explosion proof electric

More information

EX-REPAIR AND MAINTENANCE RECEPTACLES

EX-REPAIR AND MAINTENANCE RECEPTACLES EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS RTECK terminal boxes RTKB series IEC Ex EX010 TECHNICAL FILES CONTENTS: 1) Contents 2) General information 3) Safety information 4) Conformity to standards 5) Function 6) Technical

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

Clarius EP PLUS LED FLOODLIGHT Installation Guide

Clarius EP PLUS LED FLOODLIGHT Installation Guide Clarius Clarius EP PLUS LED FLOODLIGHT Installation Guide CERTIFICATION: SIRA09ATEX5159X AND IECEx SIR 09.0064X AND ABS 11-LD801943-PDA II 2 G D Ex emb IIC T4 Gb Ex t IIIC T103oC Db IP66/67 T4-20 oc to

More information

VALIADIS S.A. HELLENIC MOTORS

VALIADIS S.A. HELLENIC MOTORS Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe

More information

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

EVZ Series (Small body) Explosion protected luminaire Operating Instructions EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East

More information

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked

More information

Solenoid coil for control in potentially explosive areas Type BZ

Solenoid coil for control in potentially explosive areas Type BZ Data sheet Solenoid coil for control in potentially explosive areas Type BZ BZ is a solenoid coil with ATEX / IECEx approval, applicable for zone 1 and 2 Ex environments. The coils are designed to be used

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

-V- New. Valve series VOFC. 2009/08 Subject to change Internet: Valve series VOFC 2009/08 Subject to change Internet: www.festo.com/catalogue/... 159 Solenoid valves VOFC Key features General information The valves in the VOFC series are special 3/2-way and 5/2-way

More information

Sicherheit, auf die Sie sich verlassen können

Sicherheit, auf die Sie sich verlassen können Explosion protected switchgear CROUSE-HINDS SERIES Sicherheit, auf die Sie sich verlassen können GHG 981 Ex-Safety switch for zone 22 GRP, Stainless steel, and painted steel enclosures for harsh environments

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE

More information

Explosion and flame-proof single phase electric motors

Explosion and flame-proof single phase electric motors Explosion and flame-proof single phase electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 112 Single phase Voltage 230 50Hz Voltage 265 60Hz Types of mounting

More information

ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion EX-PROTECTION ADVANTAGES Valves for fluid technology for use in explosion hazard areas Explosion protection for gas, dust and mining Flameproof enclosures and intrinsic safety Solutions for all zones The

More information

Explosion and flame-proof cast iron electric motors

Explosion and flame-proof cast iron electric motors Explosion and flame-proof cast iron electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 160 3 phases Voltage 230/400 V 50Hz Voltage 265/460V 60Hz Types of mounting

More information

II 2GD. xxxx. Westlock 2200 Series Quantum - ATEX certified Installation & Operating Instructions

II 2GD. xxxx. Westlock 2200 Series Quantum - ATEX certified Installation & Operating Instructions Installation and operating instructions for Westlock 00 series Quantum valve control monitor with mechanical switches, inductive proximity sensors or Magnum proximity switches xxxx II GD EPSILON 08 ATEX

More information

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd 0CV2 0CV2 series dust explosion-proof three-phase asynchronous motor INSTRUCTIONS Siemens Standard Motors Ltd. 2017.02 1.0 Overview 0CV2 0CV2 series dust explosion-proof three-phase asynchronous motor

More information

EX-D ENCLOSURES AND DISTRIBUTIONS

EX-D ENCLOSURES AND DISTRIBUTIONS EX-D ENCLOSURES AND DISTRIBUTIONS Series GHG made of metal for gases of explosion group IIC To use MCBs, fuses, contactors etc. which give off arcs in potentially hazardous areas, they must be integrated

More information

Explosion protected terminal boxes type, GHG 72.

Explosion protected terminal boxes type, GHG 72. 1 Technical data 1.1 Plastic terminal boxes GHG 721... ATX type examination certificate BVS 13 ATX 013 X Marking acc. to 94/9/G and standard ATX x (d e mb) II T5* -55 T amb +55 Gb x (d e mb) II T6* -55

More information

Solenoid coils VACF Type codes

Solenoid coils VACF Type codes Solenoid coils VACF Type codes VACF B B2 1A Type VACF Solenoid coil, F series Solenoid coil type A B Width 30 mm, for 8 mm armature tube Width 22 mm, for 8 mm armature tube A1 Connection pattern type A,

More information

ADVANCE GRP Series 125A Switched Interlocked socket outlets

ADVANCE GRP Series 125A Switched Interlocked socket outlets DVNCE GRP Series 125 Switched Interlocked socket outlets DVNCE GRP Series 125 > SWITCHED INTERLOCKED SOCKET OUTLETS > REFERENCE STNDRDS EN 60309-1 Plugs, socket outlets and couples for industrial purposes.

More information

TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22

TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22 Hazardous Area Electrical Equipment TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBKS/CBKS Information Page Ask

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked in position 0 and 1 > Clear

More information

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 Equipment: Manufacturer: Type: ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION

More information

Flameproof Alternators

Flameproof Alternators Overview Standard automotive type alternators are a continuous potential source of ignition when operated in hazardous atmospheres where combustible concentrations of gas, vapor or dusts may exist. To

More information

10 Load and Motor Switchgear

10 Load and Motor Switchgear 0 Load and Motor Switchgear Motor Protection ircuitbreakers For use in Zone and Zone Zone and Zone For protection of Ex e and Ex d motors Protects cables and plant equipment Adjustable thermal overcurrent

More information

The filling level sensors are designed in accordance to the following standards

The filling level sensors are designed in accordance to the following standards Instructions according to Portaria N 179/2010 UL-BR 17.0706 Filling Level Sensors type VISY-Stick and type TORRIX Ex Version: 09.2017 I Range of application The filling level sensors are designed for continuous

More information

Zone 1 Linear Range - Installation Guide

Zone 1 Linear Range - Installation Guide Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text

More information

IS OL ATORS-EX S ERIES

IS OL ATORS-EX S ERIES IS OL ATORS-EX S ERIES Switch disconnectors for applications in potentially explosive atmospheres - DUST [ ] II 2D [ II 2D] SWITCHES DISCONNECTORS REFERENCE STANDARDS EN 60079-0 Electrical apparatus for

More information

EEX Line Spring-applied single-disc brake for potentially explosion hazardous areas

EEX Line Spring-applied single-disc brake for potentially explosion hazardous areas EEX Line Spring-applied single-disc brake for potentially explosion hazardous areas EEX Line Standard EEX Line (+50 C) / EEX Line (+60 C) EEX Line / IEC Ex EEX Line / U.S. (NEC 500/505) CSA EEX Line Industrial

More information

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content EX-AZM 161 1. About this document Operating instructions.............pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information

More information

LIST OF PUBLISHED STANDARDS

LIST OF PUBLISHED STANDARDS Report : 0-0- Page o : Of LIST OF PUBLISHED STDRDS umber SS umber pproved mendment 77 SS 96:006 Batch sampling and acceptance criteria for explosion-protected apparatus (EP) 006-0-09 0-0-09 SS 808:967

More information

Table of contents. Technical informations > ATEX Page Technical informations Page Mechanically operated valves Page 13-06

Table of contents. Technical informations > ATEX Page Technical informations Page Mechanically operated valves Page 13-06 Technical informations > Table of contents ATEX Page 13-02 Technical General informations information Page 13-02 Mechanically operated valves Page 13-06 Pneumatically operated valves Page 13-06 Electrically

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in

More information

Operating Instructions

Operating Instructions Operating Instructions Repair Light > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage and Disposal...6

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity Certificate No.: IECEx TUN 04.0006X Date of Issue: 2012-06-12 Issue No.: 3 Page 2 of 4 Manufacturer: FAFNIR GmbH Bahrenfelder Straße 19 22765 Hamburg Germany Manufacturing

More information

2/2 Solenoid Cartridge Valve, Size 6

2/2 Solenoid Cartridge Valve, Size 6 / Solenoid Cartridge Valve, Size 6 Q max = l/min (.3 gpm), p max = 3 bar (4 psi) Bidirectional leak-proof shutoff, direct acting, with EX-safty solenoid coil Description Valve: Bidirectional leak-proof

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Certificate of Conformity: IECEx BAS 07.0033X http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/9e9052... Page 1 of 4 18/06/2008 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL

More information

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX ) LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX ) Publication# 03revA Table of Contents Publication# 03revA Table Of Contents...

More information

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity Certificate No.: IECEx TUN 04.0006X Date of Issue: 2014-04-01 Issue No.: 4 Page 2 of 4 Manufacturer: FAFNIR GmbH Bahrenfelder Straße 19 22765 Hamburg Additional Manufacturing

More information

Technical Data. Dimensions

Technical Data. Dimensions Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush

More information

PY, SPY; FSQC, FP; EPC; AP

PY, SPY; FSQC, FP; EPC; AP Ex d PY, SPY; FSQC, FP; EPC; AP Sockets and plugs Aluminium alloy with low copper - Group IIC content - Zone 1, 2, 21, 22 - Aluminium alloy - Ergonomic - Plugs can be used with industrial sockets Polyester

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning

More information

ILED Dorado. User Manual

ILED Dorado. User Manual 10NM U-code Medium Intensity Obstruction Light Helideck Status Light 15NM U-code Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description...

More information

M-0. M-0... series control, monitoring and signalling devices. Ex e

M-0. M-0... series control, monitoring and signalling devices. Ex e M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere

More information

Attachments. Explosion-proof actuators. For opening and closing multileaf dampers installed in potentially explosive atmospheres (ATEX) 09/2017 DE/en

Attachments. Explosion-proof actuators. For opening and closing multileaf dampers installed in potentially explosive atmospheres (ATEX) 09/2017 DE/en X X testregistrierung Attachments Limit switch Solenoid valve Pneumatic actuator Electric actuator For opening and closing multileaf dampers installed in potentially explosive atmospheres (ATEX) for Type

More information

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion Ex-protection Explosion protection Valves for fluid technology for use in explosion hazard areas Explosion protection for gas, dust and mining Flameproof enclosures and intrinsic safety Solutions for all

More information

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13 Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact

More information

Hazardous Area Electrical Equipment. TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22. Index

Hazardous Area Electrical Equipment. TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22. Index Hazardous Area Electrical Equipment Made TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBKF/CBKF Information Page

More information

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4 SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4 U 2 1 3 3/2 Series 327 FEATURES The valves are certified according to IEC 61508 Functional Safety data and have SIL-3 capability

More information

YFC. Limit switch. Ex d. 24 operating head types

YFC. Limit switch. Ex d. 24 operating head types Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735

More information

Unused flameproof threads for cable glands have to be closed with certified plugs.

Unused flameproof threads for cable glands have to be closed with certified plugs. E X - P L U G A N D R E C E P T A C L E 1 A Metallic Design for Zone 1 The explosion-protected light metal plug and receptacle devices can be used in the areas of Zone 1 and Zone 2 at no risk of explosion.

More information

ILED Aquarius Illuminated Windsock. User Manual

ILED Aquarius Illuminated Windsock. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 3.1 The light fitting has a type plate:... 4 3.2 The junction box has a type plate:... 5 4. Product Description...

More information

International approvals.

International approvals. E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for

More information

Floodlight Range Installation Guide

Floodlight Range Installation Guide SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected

More information

B Temperature Switches

B Temperature Switches B Temperature Switches General Instructions These instructions provide information for installation n and field calibration of B Temperature Switches. Process temperature changes cause proportional vapor

More information

Modular Explosion Proof Brakes. IECLine rev 0

Modular Explosion Proof Brakes. IECLine rev 0 Modular Explosion Proof Brakes IECLine 2013 rev 0 Application example Standard B5 motor + VIS brake Standard B5 motor + VIS brake + gearbox unit Main Characteristics -PATENT pending design and concept

More information

Flameproof Enclosures

Flameproof Enclosures Flameproof Enclosures The range comprises many standard sizes of enclosures manufactured in stainless steel 316L and/or in painted carbon steel. The enclosures allow for utilization of standard electrical

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated

More information

MT/T Translated English of Chinese Standard: MT/T COAL INDUSTRY STANDARD

MT/T Translated English of Chinese Standard: MT/T COAL INDUSTRY STANDARD Translated English of Chinese Standard: MT/T249-1997 www.chinesestandard.net Sales@ChineseStandard.net COAL INDUSTRY STANDARD MT OF THE PEOPLE S REPUBLIC OF CHINA ICS 29.160.30 K 25 MT/T 249-1997 Flameproof

More information

Control and Terminal Box Type A21-**-*****

Control and Terminal Box Type A21-**-***** e pd Control and Terminal Box Exepd GmbH i_park TAUBERFRANKEN Building 23 Becksteinerstrasse 100 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control

More information

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours MIE TALK - July 2016 Compiled by Pieter H. Coetzee Introduction Far too many fires and burn injuries result from the careless or inappropriate use of petrol. Because petrol is so common in our environment,

More information

SATRON VVFe Pressure Transmitter

SATRON VVFe Pressure Transmitter SATRON VVFe pressure transmitter belongs to Vtransmitter family. SATRON VVFe is used for 0 4 kpa...0500 kpa ranges. It is a 2wire transmitter with HART standard communication. SATRON VVFe pressure transmitter

More information

EX Series User Manual

EX Series User Manual MODELS: EX90L T4 IIB 720 DS, EX90L T4 IIB 1440 SS, EX90L T4 IIC 720 SS EXIN LIGHT EX & INDUSTRIAL LIGHTING EX Series EX90L T4 IIB 720 DS, EX90L T4 IIB 1440 SS, EX90L T4 IIC 720 SS Contents 0. Introduction

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

Automatic concealed bollards 275 H600 and 275 H800 Control station

Automatic concealed bollards 275 H600 and 275 H800 Control station Automatic concealed bollards 275 H600 and 275 H800 Control station Technical installation manual CE Declaration Warnings for the installer Bollard electrical connection Technical specifications for control

More information

ATEX LABELLING FOR MOTORS AND GEAR UNITS

ATEX LABELLING FOR MOTORS AND GEAR UNITS ATEX LABELLING FOR MOTORS AND GEAR UNITS EN ATEX INFORMATION GAS AND DUST COMPLETE DRIVE SOLUTIONS FROM A SINGLE SOURCE RELIABLE n Reliable products n Coordinated components n NORD's own development and

More information

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /.. d.o.o. tel. 049 222 900, fax 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE 0403.24/.. No: TEPEx.RS.077 Rev : 0 Date: 02.2016. CONTENT 1. Manufacturer

More information

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo Explosion-proof Solenoids II 2 G / II 2 D EEx dm IIC T4, T5, T6 Catalogue Maximum photo ATEX Explosionproof solenoids with flameproof enclosure/encapsulation "dm" According to ATEX directive 94/9/EC and

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals ABB MEASUREMENT & ANALYTICS DATA SHEET TEIP11 I/P signal converter for standard signals 2 TEIP11 I/P SIGNAL CONVERTER FOR STANDARD SIGNALS DS/TEIP11-EN REV. D Flow in air pressure Proven and reliable concept

More information

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Reg No: 1999/027771/07 (Pty) Ltd 7 Spanner Rd / PO Box 467 Olifantsfontein 1665 Tel: +27 (11) 316 4601 Fax: +27 (11) 316 5670 E-mail: admin-mgr@explolabs.co.za GOVERNMENT APPROVED TEST LABORATORY IN TERMS

More information

Operating instructions According to Directive 2014/34/EU (ATEX) Annex II p group II, equipment category 1/2D

Operating instructions According to Directive 2014/34/EU (ATEX) Annex II p group II, equipment category 1/2D 1. Introduction Fig.1 MAX. ( Process ) MIN. ( Ambient ) The Rotative Level Control RL-A AD1/2* are used to detect the level of materials such as dust or granules in containers. They are supplied with plastic

More information

Solenoid coils. Festo core product range Covers 80% of your automation tasks

Solenoid coils. Festo core product range Covers 80% of your automation tasks Solenoid coils q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

CCAI, CCAIF, CCAIF..H

CCAI, CCAIF, CCAIF..H CCAI, CCAIF, CCAIF..H - Zone 1, 2, 21, 22 - Group IIC - Stainless steel junction boxes - Choice of 4 sizes - IP66 AISI 316L stainless steel Grub screws for opening lid Lid opening system Detail of inside

More information

Floodlight LED Series 6125

Floodlight LED Series 6125 www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated

More information

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518 3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

2-way pilot operated solenoid valves for water, hot water and steam. Catalogue 8658/GB December 1999

2-way pilot operated solenoid valves for water, hot water and steam. Catalogue 8658/GB December 1999 -way pilot operated solenoid valves for water, hot water and steam Catalogue 88/GB December 999 88/GB Technical specifications General description The Water Valves are diaphragm operated valves and require

More information

MAKING MODERN LIVING POSSIBLE. Coils for solenoid valves. Technical brochure

MAKING MODERN LIVING POSSIBLE. Coils for solenoid valves. Technical brochure MAKING MODERN LIVING POSSIBLE Technical brochure 2 DKRCC.PD.BS0.A4.02-520H1701 Danfoss A/S (AC-AKC/ frz), 10-2009 Introduction The coils are specially designed to operate in the aggressive environment

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive Switches in conformity with ATX directive 2/3 General Catalog 3-4 Technical concepts page 2/39 Position switches FD series page 2/4 Category Zone PL Approvals 2G Gb Mb II 2G x ia IIC T6 Gb I x ia I Mb

More information

Low voltage Motors for explosive atmospheres Installation, operation, maintenance and safety manual

Low voltage Motors for explosive atmospheres Installation, operation, maintenance and safety manual Low voltage Motors for explosive atmospheres Installation, operation, maintenance and safety manual Installation, operation, maintenance and safety manual... EN 3 Montage-, Betriebs-, Wartungs- und Sicherheitsanleitung...

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive Switches in conformity with ATX directive 2/3 General Catalog -2 Technical concepts page 2/39 Position switches FD series page 2/4 Category Zone PL Approvals 2G Gb Mb II 2G x ia IIC T6 Gb I x ia I Mb Article

More information

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C) Parker Lucifer Data Sheet 22062004 General information Lucifer ref.: 341N31 Global ref.: 7341NAKBJNM0 Housing ref.: 2995 Coil ref.: 481865 Protection class: Assembly wt. (g): 510 Body: Seat disc: Anod.

More information

Miretti Flameproof 1MIRETTI. Technology Jan. 1st, 2014 Editor: Max Huang Mp:

Miretti Flameproof 1MIRETTI. Technology Jan. 1st, 2014 Editor: Max Huang   Mp: Miretti Flameproof 1 Technology Jan. 1st, 2014 Editor: Max Huang Email: Max.huang@miretti.net Mp: +86-158 2100 7175 1 MARKETS Miretti products: 2 flameproof conversions of: Electric & diesel forklift trucks

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx UL 13.0077U issue No.:1

More information

Short form catalogue ATEX certified products

Short form catalogue ATEX certified products Short form catalogue certified products Products classified for the use in potentially esplosive atmospheres (Directive Atex 94/9/CE) As from the first of July 2003, all products which are commercialised

More information

For mounting on subbase or footprint in accordance with CNOMO recommendation E 06620N Part numbers (and voltages) Voltage max. power consumption U nom

For mounting on subbase or footprint in accordance with CNOMO recommendation E 06620N Part numbers (and voltages) Voltage max. power consumption U nom Intrinsically Safe Miniature Solenoid Valves Order/Technical Support Tel: (800) 6775 / FAX: (800) 677865 / www.crouzetusa.com 5/6 5 For mounting on subbase or footprint in accordance with CNOMO recommendation

More information

Intrinsically Safe Miniature Solenoid Valves

Intrinsically Safe Miniature Solenoid Valves Intrinsically Safe Miniature Solenoid Valves 5 Order/Technical Support Tel: (800) 6775 / FAX: (800) 677865 / www.crouzetusa.com 5/6 Intrinsically safe miniature solenoid valves EEx ia T6 approval no. 9

More information

MAGNETIC MOTOR STARTERS

MAGNETIC MOTOR STARTERS Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors

More information

Operating Instructions

Operating Instructions Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety

More information