1 PRODUCT 21FL/26FL/38FL/42FL PD-CLFL-03A FILTRATION EQUIPMENT SERIES 21FL/26FL/38FL/42FL FILTER LOCK HOUSINGS Filter Lock The BLC Filter Lock Housing sets the industry standard for ASHRAE filtration Anywhere that minimal air bypass or leakage is especially sensitive is an application where BLC s Filter Lock should be applied Developed exclusively for medium to high efficiency filtration in general ventilation requirements, our custom designed unit depths provide a vehicle for which standard 65% - 95% ASHRAE filters may be applied or utilized This allows our customers enormous flexibility, versatility and reliability when choosing a housing for a particular specification Each Filter Lock Housing is equipped standard with a 2" or 4" prefilter track Downstream from the prefilter is BLC s special Locking Mechanism This mechanism incorporates a series of high pressure springs and clamps to lock or secure a 1" header type or a 4" panel type final filter to an EPDM gasketed tracking member, hence establishing a facial seal eliminating bypass This design enables the BLC Filter Lock to be utilized in any number of special applications Completely factory assembled, the Filter Lock is engineered to provide a rugged one piece housing that is ready for immediate installation when received at the job site These housings are offered standard in sizes ranging from 1 foot wide x 2 feet high through 10 feet wide x 7 feet high Additionally, larger special sizes are also available All models and depths of the BLC Filter Lock Housing require only 2 sizes of filters, 12 x 24 and 24 x 24 (nominal) in 2, 4 and 1 inch depths, thereby reducing stocking requirements and eliminating confusion when change-out of the filters are required CONSTRUCTION BLC s aluminized steel provides superior corrosion and heat resistance, resulting in longer product life and appearance Aluminized steel also offers an improved overall product appearance when compared to galvanized material In addition, aluminized steel conforms to ASTM Specification A463 and is used for such applications as space heaters, mufflers and incinerators which are subjected to extremely corrosive conditions Each Filter Lock Housing is supplied with 2 lift-off access doors hinged at the rear of the housing for easy access to filters The door is fully gasketed at its perimeter and at filter tracks by use of an EPDM gasket Quick acting, over-center, positive lock latches are used to secure doors without bypass This standard design will withstand positive or negative pressure up to 3" WG CONSTRUCTION FEATURES 16 GAUGE ALUMINIZED STEEL CONSTRUCTION FACTORY ASSEMBLED LIFT-OFF ACCESS DOORS GASKETED ACCESS DOORS FILTER LOCK MECHANISM 1 1/2" MOUNTING FLANGES Corporate Headquarters PO Box 14187, Louisville, Kentucky Phone: (502) Fax: (502) askus@blcindcom BLC-WEST Phone: (480) Fax: (480) wwwblcindcom We reserve the right to make changes in product design and product specifications without prior notice or obligation Breathe Easy, We Have The Line On Air Filtration

2 Series 21FL, 26FL, 38FL and 42FL: Options FILTER INFORMATION 21" FILTER LOCK HOUSING 2" or 4" Prefilter/4" Panel Final Filter Maximum depth of Final Filter - 4" 26" FILTER LOCK HOUSING 2" or 4" Prefilter/1" Header Final Filter Maximum depth of Final Filter with: 2" Prefilter - 15", 4" Prefilter - 15" 38" FILTER LOCK HOUSING 2" or 4" Prefilter/1" Header Final Filter Maximum depth of Final Filter with: 2" Prefilter - 28", 4" Prefilter - 26" 42" FILTER LOCK HOUSING 2" or 4" Prefilter/1" Header Final Filter Maximum depth of Final Filter with: 2" Prefilter - 32", 4" Prefilter - 30" BLC offers weatherproofing of units for outside installations Weatherproofing consists of a pitched roof mounted to the top of the housing with rain guards over the doors and a permanent (non silicon) sealer at all seams Insulation is also available A 1 inch thick insulation of 1 1/2 pound density can be applied to all exposed surfaces as specified BLC s Double Wall Insulation combats vibration, noise and condensation -- protecting the quality of the filtered air With this application, the insulation is enclosed and captured with 24 gauge aluminized panels ensuring the insulation s integrity for the life of the unit Adapter flanges for all commercial air handling units and adapter flanges to meet any ductwork requirements are available as needed In addition, Stainless Steel, Epoxy Coating or High Pressure construction can also be readily provided EQUIPMENT OPTIONS INSULATION DOUBLE WALL INSULATION WEATHERPROOFING HIGH PRESSURE FLANGE ADAPTERS SUPPORT LEGS HANGER BRACKETS STATIC TAPS STAINLESS STEEL These and other specialty options are available, please contact factory for further information Dimensional Data HEIGHT ACTUAL CODE HEIGHT (Nominal) MODEL EXT /4" MODEL EXT 500 FPM FILTER QTY MODEL EXT /16" 500 FPM FILTER QTY MODEL EXT /16" 500 FPM FILTER QTY MODEL EXT /8" 500 FPM FILTER QTY MODEL EXT /8" 500 FPM FILTER QTY MODEL EXT /16" 500 FPM /16" FILTER QTY MODEL EXT 500 FPM FILTER QTY WIDTH CODE (Nominal) ACTUAL WIDTH 11 1/2" 23 1/2" 35" 47" 58 1/2" 70 1/2" 82" 94" 105 1/2" 117 1/2" 01X06 3H 01X H 01X H 02X07 1H 3F 02X06 3F 02X H 2F 02X04 2F 02X03 1H 1F 02X F 02X H 03X07 4H 3F 03X H 3F 03X05 3H 2F 03X04 2H 2F 03X03 2H 1F 03X02 1H 1F 04X07 1 2H 6F 04X06 6F 04X05 2H 4F 04X F 04X03 2H 2F 04X02 2F 04X H 05X07 1 5H 6F 05X H 6F 05X05 4H 4F 05X04 2H 4F 05X03 3H 2F 05X H 2F 06X H 9F 06X F 06X H 6F 06X04 6F 06X H 3F 06X02 3F 06X01 3H 07X07 2 6H 9F 07X H 9F 07X05 1 5H 6F 07X04 1 2H 6F 07X03 4H 3F 07X02 1H 3F 08X H 12F 08X F 08X H 8F 08X04 1 8F 08X03 4H 4F 08X F 08X01 4H 09X H 12F 09X06 2 3H 12F 09X H 8F 09X H 8F 09X03 1 5H 4F 09X H 4F 10X H 15F 10X F 10X H 10F 10X F 10X H 5F 10X02 5F 10X H 1 H denotes half size filter /8 x 23 3/8 2 F denotes full size filter /8 x 23 3/8 3 denotes unit requires an 11 3/8 x 11 3/8 blank off panel, which is supplied 4 Unit depth is 21", 26", 38" or 42" Insert model number extension to complete model number MODEL NUMBER KEY *26 FL10X05 *Insert 21FL, 26FL, 38FL or 42FL for unit depth 26- FL " Depth Filter Lock Unit Width Unit Height

3 SPECIFICATION 21FL/26FL/38FL/42FL SPD-CLFL-03A FILTRATION EQUIPMENT FILTER LOCK HOUSING 21"/26"/38"/42" FILTER LOCK HOUSINGS SPECIFICATIONS:! Completely Factory Assembled! 16 Gauge Aluminized Steel! Lift-Off Access Doors! 2" or 4" Prefilter Track! Locking Mechanism With High Tension Springs and Clamps! Fully Gasketed Tracks and Doors OPTIONS: Insulation Double Wall Insulation Weatherproofing High Pressure Flange Adapters Support Legs Hanger Brackets Static Taps Stainless Steel FLOW 2" Prefilter 1" Final Bag Filter Locking Mechanism C L E A N A I R CUT SIDE VIEW WITHOUT THE DOOR Corporate Headquarters PO Box 14187, Louisville, Kentucky Phone: (502) Fax: (502) askus@blcindcom BLC-WEST Phone: (480) Fax: (480) wwwblcindcom We reserve the right to make changes in product design and product specifications without prior notice or obligation Breathe Easy, We Have The Line On Air Filtration

4 MECHANICAL SPECIFICATIONS - CLEAN-LINE FILTER LOCK HOUSINGS Filter housings shall be CLEAN-LINE 21, 26, 38 or 42 Filter Lock Housings as manufactured by BLC Industries, Inc Units shall be completely factory assembled with 1 1/2" mounting flanges provided for field installation Standard design for 3" WG positive or negative pressure Units shall include the following equipment features and options: STANDARD UNIT CONSTRUCTION Material of Construction Filter Lock Housing(s) shall be manufactured of 16 gauge aluminized steel All fasteners are to be corrosion resistant finish Track System Filter Lock Housing(s) filter tracks shall provide for either a 2" or a 4" prefilter and a 1" header type final filter Each filter track is sealed at its end by use of EPDM gasket Filter Locking Mechanism Filter Lock Housing(s) shall be provided with a final filter locking mechanism The locking mechanism is operated by over-center type clamps which force the filter against a sealing channel gasketed with EPDM gasket, sealing the filter at its top/bottom on the downstream side of the filter header Spring loading of the locking mechanism clamps maintain a positive pressure of 600 ft lbs per filter Standard location of locking mechanism is at right hand door Housing(s) 09 or 10 wide require access on both ends of the unit for dual set of locks Access Doors Filter Lock Housing(s) shall be provided with two hinged access doors Doors to be sealed with over-center draw latches Door perimeters are sealed with EPDM gasket UNIT OPTIONS Insulation Filter Lock Housing(s) shall be provided with 1 inch thick insulation Insulation is applied to the interior of the access doors and to the exterior of the top and bottom panels Insulation may be 15 pound or 30 pound density Double Wall Insulation Filter Lock Housing(s) shall be provided with 1 inch thick double wall insulation Insulation shall be enclosed in 24 gauge aluminized steel panels located on the interior of the access doors and the exterior of the top and bottom panels Insulation may be 15 or 30 pound density Weatherproofing Filter Lock Housing(s) shall be provided with a 16 gauge aluminized steel pitched rain roof All seams shall be sealed using a high viscosity permanent sealer (non-silicon) High Pressure Filter Lock Housing(s) shall be provided to meet operating static pressure of 10 IN WG (Positive/Negative) Access doors are provided with full length piano hinges welded in place (Doors not lift off) Consult factory for all other high pressure applications Mounting Flange Adapters Filter Lock Housing(s) shall be provided with 16 gauge aluminized steel flat adapter flange to match customer equipment/ specifications Flanges may be single-air entering, single-air leaving or double-air entering and air leaving per customer requirements Support Legs Filter Lock Housing(s) shall be provided with 12 gauge aluminized steel support legs Maximum height of 6 inches from bottom of flange to floorline Quantity of support legs are as follows: 01 ft - 04 ft wide units/2 support legs, 05 ft - 07 ft wide units/3 support legs, 08 ft - 10 ft wide units/4 support legs For other applications, consult factory Hanger Brackets Filter Lock Housing(s) shall be provided with 12 gauge aluminized steel hanger brackets welded to the top panel Location may be one (1) pair of brackets - air entering/top corners, one (1) pair of brackets - air leaving/top corners or (2) pair of brackets on all four corners Brackets are supplied with a 5/8" diameter hole for hanger rod Hanger brackets are for support of the filter housing only Any other equipment or duct connections must be supported independently Static Taps Filter Lock Housing(s) shall be supplied with static pressure fittings for 1/4" metal tube connection Tap Location No 1: Before filter Tap Location No 2: Between prefilter and final filter Tap Location No 3: After final filter Alternate Material of Construction Filter Lock Housings shall be manufactured of 304 or 316 stainless steel Standard aluminized units shall be supplied with an air dried epoxy coating Epoxy coating can be interior-only, exterior-only or interior and exterior

5 SUBMITTAL CLEAN-LINE FI AN-LINE FILTER L TER LOCK HOUSING SD-CLFL-03A BLC Order Number Customer Project Name Tag Purchase Order Ship Date BLC Model Number Qty Width Notes Door Location 2 Doors - (STANDARD) 1 Door - Right 1 Door - Left MODEL WIDTH /2 1" Header Height Prefilter Information: 2" Panel 4" Panel Final Filter Information: / " Panel Unit Depth 21" - 2" Pre / 4" Final Filter 26" -2" or 4" Pre / 1" Final Filter Weatherproofing Double Wall Insulation 15# 30# Stainless Steel Alloy High Pressure POS NEG WG /2 Support Legs Hanger Brackets Adapters / Air Entering Air Leaving Both / /2 38" - 2" or 4" Pre / 1" Final Filter 42" - 2" or 4" Pre / 1" Final Filter Air Filter Monitoring Information Static Taps Air Filter Gage Locations - (See Note 4) Model FILTER INFORMATION (For each unit shown at left) By Others* Initial Supply Spare Set *BLC provides no warranty as to the fit or performance of air filters supplied by others Number Required - 12 x24 Number Required - 24 x24 Field Mount Custom Factory Mount By Others MODEL HEIGHT 85 3/4 74 1/ / /8 Plan Air Flow Unit Width Lift-Off Hinged Access Doors 3"-0" Recommended For Service Unit Depth Unit 500 FPM Prefilter Type 12x24 Model Number 24x24 Model Number ASHRAE Efficiency Initial Pressure Drop NOTES: 38 3/ / /16 1 MATERIAL OF CONSTRUCTION: 16 GAUGE ALUMINIZED STEEL 2 UNITS ACCOMMODATE 11 3/8 X 23 3/8 OR 23 3/8 X 23 3/8 INCH FILTERS 3 OPTIONAL HIGH PRESSURE UNIT: DOORS HINGED BY USE OF PIANO HINGE WELDED IN PLACE NOT LIFT-OFF 4 OPTIONAL STATIC TAP LOCATION: 1- BEFORE PREFILTER 2- BETWEEN PRE AND FINAL FILTER 3- AFTER FINAL FILTER 5 LOCKING MECHANISM ACTIVATED FROM SIDE OF SINGLE DOOR UNITS TWO (2) DOOR UNITS, LOCKING MECHANISM RIGHT HAND DOOR UNIT WIDTHS OF 09 AND 10 REQUIRE TWO (2) DOORS AND ACCESS BOTH ENDS TO ACITVATE LOCKING MECHANISMS BLC INDUSTRIES, INC 1 1/2" Perimeter Flange, Undrilled Front Elevation Unit Height LOUISVILLE, KENTUCKY PHONE: (502) FAX: (502) Air Flow End Elevation wwwblcindcom Recommended Final Final Filter Type 12x24 Model Number 24x24 Model Number ASHRAE Efficiency Initial Pressure Drop Recommended Final Approved/Date Breathe Easy, We Have The Line On Air Filtration

6 TECHNICAL SERIES FL TD-CLFLI0I-A FILTRATION EQUIPMENT SERIES FL INSTALLATION AND OPERATION INSTRUCTIONS INSTALLATION AND OPERATION INSTRUCTIONS FILTER LOCK HOUSINGS ORDER NUMBER: SERIAL NUMBER: Corporate Headquarters PO Box 14187, Louisville, Kentucky Phone: (502) Fax: (502) wwwblcindcom BLC-WEST Phone: (480) Fax: (480) We reserve the right to make changes in product design and product specifications without prior notice or obligation Breathe Easy, We Have The Line On Air Filtration

7

SERIES ARH INSTALLATION AND OPERATION INSTRUCTIONS FOR THE HORIZONTAL AUTOROLL & MANUROLL

SERIES ARH INSTALLATION AND OPERATION INSTRUCTIONS FOR THE HORIZONTAL AUTOROLL & MANUROLL TECHNICAL DATA AUTO-LINE TM SERIES ARH FEBRUARY 2004 AUTOMATIC AIR FILTRATION EQUIPMENT AUTO-LINE TM SERIES ARH INSTALLATION AND OPERATION INSTRUCTIONS FOR THE HORIZONTAL AUTOROLL & MANUROLL INSTALLATION

More information

GRAVITY VENTILATORS SIZING

GRAVITY VENTILATORS SIZING GRAVITY VENTILATORS SIZING RCXII (sizes 6-20) RCXII (sizes 24-36) RCXII-SF BGH RLX Sizing The tables shown offer quick selections at common static pressure points. Selection choices vary widely due to

More information

SECTION HVAC AIR CLEANING DEVICES

SECTION HVAC AIR CLEANING DEVICES SECTION 23 40 00 HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes activated carbon filters, automatic renewable media filters, disposable, extended area panel filters, disposable

More information

Issue 4 (Record Only) Job #: Innovent Submittal Date: October 30, 2012 Project: Location: Columbus, OH Innovent Job #: Submittal Issue: 4 (Record Only) Engineer: Contractor: Tag Innovent Model # AHU-BG-01

More information

Rigid-Air Spun Glass or Synthetic Media Rigid Filter PB

Rigid-Air Spun Glass or Synthetic Media Rigid Filter PB Rigid-Air Spun Glass or Synthetic Media Rigid Filter PB1001-112304 General Rigid-Air extended media surface rigid filters are designed for use in most commercial or industrial HVAC systems where medium

More information

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction. Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

BioMAX. Koch Filter Corporation. A Complete Line of HEPA Filters for Hospital, Commercial and Industrial Applications

BioMAX. Koch Filter Corporation. A Complete Line of HEPA Filters for Hospital, Commercial and Industrial Applications Koch Filter Corporation Filtration Products Crafted with Pride BioMAX A Complete Line of HEPA Filters for Hospital, Commercial and Industrial Applications Available in three efficiencies on 0.3 micron

More information

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System V-Series (rev. 08/17/10) Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System Note: Optional items and/or items requiring a choice, are shown between brackets and/or parentheses

More information

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES SECTION - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this

More information

Hi-Flo ES. Energy saving pocket filter with guaranteed lifetime efficiency. Energy Saving, Extended Surface Area, High Efficiency Air Filter

Hi-Flo ES. Energy saving pocket filter with guaranteed lifetime efficiency. Energy Saving, Extended Surface Area, High Efficiency Air Filter Hi-Flo ES Energy Saving, Extended Surface Area, High Efficiency Air Filter Air filters are the first line of defense to protect people and processes in buildings. The Camfil Hi-Flo ES can remove contaminants

More information

P&G MANUFACTURING INC.

P&G MANUFACTURING INC. P&G MANUFACTURING INC. Bag-In/Bag-Out Operation and Maintenance Manual Table of Contents SECTION PAGE Manufacture s Message 3 Introduction 4 Handling and Storage of Filter Elements 9 Installation of New

More information

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

HORD HOSPITAL OPERATING ROOM AIR CURTAIN HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain

More information

HCD-230 Industrial Control Damper

HCD-230 Industrial Control Damper Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

EGG CRATE RETURN GRILLE

EGG CRATE RETURN GRILLE 80 EGG CRATE RETURN GRILLE 80 The 80 Series is available in various mounting styles and features sturdy construction, consisting of a heavy gauge aluminum grid core, optional extruded aluminum borders

More information

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410. PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

HORD HOSPITAL OPERATING ROOM AIR CURTAIN HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain

More information

Maxi-Grid. A Complete Line of Internally-Supported Panel Filters. Koch Filter Corporation

Maxi-Grid. A Complete Line of Internally-Supported Panel Filters. Koch Filter Corporation Koch Filter Corporation Filtration Products Crafted with Pride Maxi-Grid A Complete Line of Internally-Supported Panel Filters Self sealing design Progressive density media Durable steel internal support

More information

ACCESS DOORS GENERAL PRODUCT OVERVIEW

ACCESS DOORS GENERAL PRODUCT OVERVIEW GENERAL PRODUCT OVERVEW Fire dampers need inspecting and testing, coils need cleaning and controls need adjusting. Nailor ndustries offers a range of duct and plenum access doors that have been designed

More information

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS MODEL FEATURES Supply air to over 56,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Filtered models available

More information

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias SUBMITTAL Project Palm Beach Gardens Fire Station Date February 5, 2018 Fausto Frias Prepared For TLC Attention- Steve Job Name Palm Beach Gardens Fire Station Mark for AHU-1 Date February 5, 2018 Unit

More information

Filtered Kitchen Supply Packaged Ventilator

Filtered Kitchen Supply Packaged Ventilator Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

Climas y Proyectos Leyco, S.A. de C.V.

Climas y Proyectos Leyco, S.A. de C.V. GENERAL DESCRIPTION : FURNISH AND INSTALL MULTI COMPONENT ROOF MOUNTED LEYCO, MODEL CAH CUSTOM AIR HANDLER MADE SELF-CONTAINED, WEATHER RESISTANT, AIR HANDLING UNITS PER MODEL NUMBER, AND PERFORMANCE DATA

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Tube Axial Inline Fans

Tube Axial Inline Fans Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the

More information

ARROW INDUSTRIAL PRODUCTS

ARROW INDUSTRIAL PRODUCTS IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products

More information

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS MODEL FEATURES Exhaust air to over 40,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Reversible blades

More information

FRP Fans: CLUB Series Performance and Technical Information

FRP Fans: CLUB Series Performance and Technical Information FRP Fans: CLUB Series 1500-7300 Performance and Technical Information Verantis Environmental Solutions Group provides solutions for most common and complex situations including repair, rebuilding, field

More information

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems Medium Pressure Axial Fans Model TBI-FS Levels 3, 4 & 5 with Fabricated Steel Propeller Belt Drive Inline or Roof Mounted Upblast Clean Air or Fume Exhaust High Temperature Process Exhaust Emergency Smoke

More information

GRAVITY VENTILATORS SIZING

GRAVITY VENTILATORS SIZING GRAVITY VENTILATORS SIZING BGH RLX Sizing The tables shown offer quick selections at common static pressure points. Selection choices vary widely due to field conditions and size choices. The following

More information

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI Bulletin 8510-4 May 2000 Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI Description Index Series 8500 Centrifugal Swingout Fans The Series 8500 Centrifugal

More information

2520- EC Motor Speed Controller

2520- EC Motor Speed Controller 2520- EC Motor Speed Controller T1 AC Line Voltage From Contactor T2 or Neutral 760-ECM ECM Motor BLACK ORANGE BLACK RED (+) Signal 24VAC (-) GND Features Motor Types: ECM (dc brushless) Motors Motor Speed:

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MEL FEATURES Exhaust air up to 28,000 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Belt drives permit easy performance adjustments when needed Non-overloading

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

Model ND-2 Specification

Model ND-2 Specification Model ND-2 Specification The model ND-2 is an exhaust only canopy hood rated for all types of cooking equipment. The hood shall have the size, shape and performance specified on drawings. Construction

More information

XeteX, Inc. All Rights Reserved.

XeteX, Inc. All Rights Reserved. Model XC Indoor or outdoor mounted, simple, in-case aluminum flat plate exchanger with options for frost control. Ideal for inline installations: in duct-work systems, in built-up units, or in modular

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD MEL FEATURES Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Inline and Roof Mounted Fans

Inline and Roof Mounted Fans CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive

More information

Low Silhouette Power Roof Ventilator Propeller

Low Silhouette Power Roof Ventilator Propeller LOW SILHOUETTE Models LT, LG and LF Power Roof Ventilator Propeller Contemporary Styling Carnes line of low silhouette power roof ventilators are ideal for installations requiring high performance and

More information

Horizontal. AutoRoll.

Horizontal. AutoRoll. PROUCT ATA SRIS ARH P-ALARH-03A JANUARY 2003 AUTOMATIC FILTRATION QUIPMNT SRIS ARH AUTOROLL - HORIZONTAL ngineered by dedicated personnel with years of experience and hands-on application expertise, the

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

Thirteen (13) UL listed fluorescent fixtures per booth will supply illumination.

Thirteen (13) UL listed fluorescent fixtures per booth will supply illumination. Quoted as per your request: two (2) Non-Pressurized, Drive-Thru, Full Down Draft, Paint Booth model: TDD-16-16-20-DT with interior working dimensions of 16-0 wide X 16-0 tall X 20-0 long. Overall dimensions

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST ROOF VENTILATORS LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) CATALOG 4870 April 17 ROOF VENTILATORS Overview Propeller Roof

More information

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES

More information

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume PennBarry Fan Guide Specification Laboratory Exhaust System: Model vplume This document 2018 PennBarry vplume is a commercial lab exhaust fan that ensures a greater margin of safety by effectively dispersing

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing

More information

PC-125x Counter-Balanced Backdraft Damper

PC-125x Counter-Balanced Backdraft Damper PC-15x Counter-Balanced Backdraft Damper Product Bulletin Code No. LIT-101180 Issued April 7, 015 Refer to the QuickLIT Web site for the most up-to-date version of this document. Since 1885, Johnson Controls

More information

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS Air Zoë Centrifugal Inline Duct fans have been developed to efficiently handle the

More information

SECTION HVAC POWER VENTILATORS

SECTION HVAC POWER VENTILATORS SECTION 233423 HVAC POWER VENTILATORS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP CATALOG 4135 February 2017 PENTHOUSE ROOF VENTILATORS Overview DCLH I BCLH I DCLP I BCLP Model

More information

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG BULLETIN 671 AUGUST, 2016 VANEAXIAL FANS DUCT FANS Capacities to 60,000 Static pressures to 2 WG TUBEAXIAL FANS Capacities to 86,000 Static pressures to 3 WG Capacities to 0,000 Static pressures to 5 WG

More information

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42V Air Measuring Station with VCD-42V Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) 14 ga. (2mm) Frame Type 5 in. x 1 in. hat channel - Blade

More information

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper Application and Design W x H Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness External Minimum Size 16 ga. (1.5mm) Internal Single Section Maximum Size Multiple

More information

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc. ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.

More information

WELCOME. Give us a call.

WELCOME. Give us a call. Filter Catalog WELCOME The Facility Maintenance Solutions Company Welcome to Tri-Chem Corporation. For over 40 years we have been helping organizations, just like yours, with their toughest facility maintenance

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

A Division of Nailor International Inc. ECONOMY AIR HANDLERS A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical

More information

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION HVAC AIR CLEANING DEVICES

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION HVAC AIR CLEANING DEVICES ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT ZONE INTERNATIONAL MIXED- COLUMN UNIT 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM ZONE INTERNATIONAL MIXED- COLUMN UNIT T DUCT COLLAR INLET (A x B) PRIMARY RETURN

More information

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information

More information

SECTION CENTRIFUGAL HVAC FANS

SECTION CENTRIFUGAL HVAC FANS SECTION 233416 - CENTRIFUGAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty Submittal Data Model PELV-100 Penthouse Elevator Vented Hood Application and Design The PELV-100 Penthouse Elevator Vented Hood is a gravity ventilator penthouse with an 18" x 18" gasketed access door

More information

FSD60/MFSD60 Multi-blade Fire Damper

FSD60/MFSD60 Multi-blade Fire Damper DAMPER FSD60/MFSD60 Multi-blade Fire Damper Tested and conform to Tested and conform to BS476:Part20:1987 The ASLI Multi-Blade Fire Dampers have been developed to provide the versatility required for today

More information

Installation Instructions

Installation Instructions CAHZCOIL8A00 CAHZCOIL412A00 CAHZCOIL208A00 CAHZCOIL212A00 CAVTCOIL8A00 CAVTCOIL412A00 CAVTCOIL208A00 CAVTCOIL212A00 Installation Instructions DIRECT --- EXPANSION HORIZONTAL AND VERTICAL EVAPORATOR COILS

More information

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG CATALOG 4720 MAY 2014

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG   CATALOG 4720 MAY 2014 Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG CATALOG 4720 MAY 2014 WWW.TCF.COM GRAVITY VENTILATORS Overview Gravity Ventilators Models

More information

Introduction to Johnson Controls Dampers

Introduction to Johnson Controls Dampers Damper and Actuator Product Guide 268.1 Damper Engineering Section Product Bulletin Issue Date 1297 Introduction to Johnson Controls Dampers For over 100 years, Johnson Controls has been the industry leader

More information

Ford Fabricated Steel Products

Ford Fabricated Steel Products Ford Fabricated Steel Products Section N2 12/2000 The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 219/563-3171 FAX: 1-800-826-3487 Overseas

More information

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES OSU PROJECT NO. 30-04-15 PAGE 1 PART 1 GENERAL 1.1 WORK INCLUDED A. Medium and low pressure duct accessories, sealants and tapes, flexible connectors, fire dampers, smoke dampers, combination smoke and

More information

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section SECTION 15910 DUCT ACCESSORIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division-1 Specification Sections,

More information

Bulletin VX05 VANEAXIAL FANS

Bulletin VX05 VANEAXIAL FANS Bulletin VX05 VANEAXIAL FANS Models: VXD, VXB Direct Drive and Belt Drive s VXD/VXB Introduction CERTIFIED RATINGS AMCA Certification UL Certification PennBarry certifi es that the Vaneaxial fans shown

More information

SECTION DUCTWORK ACCESSORIES

SECTION DUCTWORK ACCESSORIES SECTION 15910 DUCTWORK ACCESSORIES PART 1- GENERAL SCOPE This sections includes accessories used in the installation of duct systems. Included are the following topics: PART 1- GENERAL Related Work Reference

More information

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators Version: Dec. 01, 2004 RERV & RERVX Rotary Energy Recovery Ventilators Indoor and Outdoor Installations 250 20,000 CFM Capacities RERVLP Low Profile Indoor Rotary Energy Recovery Ventilators Ideal for

More information

Airpocket Select Ultrasonically-sealed

Airpocket Select Ultrasonically-sealed Airpocket Select Ultrasonically-sealed Product Range KEY FACTS Ultrasonically sealed for strength and performance Resists microbial growth Longitudinal separators for an even air distribution DESIGN Applications

More information

INSULATED CANTED ROOF CURB NON-PROPELLER PRODUCTS

INSULATED CANTED ROOF CURB NON-PROPELLER PRODUCTS INSULATED ANTED ROOF URB NON-PROPELLER PRODUTS Wood Nailer A 3" 3/4" 3" 1" Semi-Rigid Insulation Damper Shelf (Optional) (1) B OPTIONS: 1. Damper Shelf. 2. Metal Liner - solid or screen type. 3. Burglar

More information

INSULATED CANTED ROOF CURB NON-PROPELLER PRODUCTS

INSULATED CANTED ROOF CURB NON-PROPELLER PRODUCTS INSULATED ANTED ROOF URB NON-PROPELLER PRODUTS Wood Nailer A OPTIONS: 1. Damper Shelf. 2. Metal Liner - solid or screen type. 3. Burglar bars - 1/2" dia. on 6" centers. 4. Finishes - baked or air-dried

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS COMMERCIAL KITCHEN APPLICATIONS Belt Driven Model VRBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

SINGLE DUCT TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product

More information

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent Technical and Dimensional Data Saf-T Vent EZ Seal Single Wall AL 29-4C Stainless Steel Special Gas Vent 130 Industrial Boulevard Turners Falls, MA 01376 Copyright 2001 Heat-fab, Incorporated Saf-T Vent

More information

Gravity Ventilators. Models FGI and FGR. Fabra Hood Intake and Relief

Gravity Ventilators. Models FGI and FGR. Fabra Hood Intake and Relief Gravity Ventilators Models FGI and FGR Fabra Hood Intake and Relief July 008 Page Fabra Header Hood Greenheck Fabra Hoods are designed for intake (Model FGI) or relief (Model FGR) applications with either

More information

VANEAXIAL & TUBEAXIAL FANS

VANEAXIAL & TUBEAXIAL FANS BULLETIN 482 July 2008 VANEAXIAL & TUBEAXIAL FANS Type "S" Belt Driven Featuring Welded Steel Propellers Models VSBD & TSBD Model TSBD Belt Driven Tubeaxial Type "S" Vaneaxial & Tubeaxial Fans For applications

More information

ARROW UNITED INDUSTRIES

ARROW UNITED INDUSTRIES IP-3R ARROW UNITED INDUSTRIES Building Tomorrow s Ventilation Today Heavy Duty Dampers Industrial, Power Plant & Commercial Applications ARROW UNITED INDUSTRIES has specialized in the design and manufacturing

More information

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN MODEL BCRFS CATALOG 4310 JUNE 2012 FILTERED SUPPLY VENTILATORS Model BCRFS Twin City

More information

University of Delaware

University of Delaware SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section

More information

The Worldwide Leader in Concrete Paving Technology

The Worldwide Leader in Concrete Paving Technology The Worldwide Leader in Concrete Paving Technology 4400 Barrier Paver: True Right-Side and Left-Side Slipforming GOMACO U-shaped operator s platform, with vibration isolation, puts the operator comfortably

More information

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Positive Seal Damper Blades with Vinyl Gaskets 2.5 SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS BACKDRAFT DAMPERS BLADE OPTION: SR: 0.016-0.020 roll formed aluminum with vinyl gasket - used with fan motors under 1 HP SE: 0.05 extruded aluminum with vinyl gasket - used with fan motors over 1 HP Positive

More information

ID-141x 12-Gauge Hat Channel Industrial Damper

ID-141x 12-Gauge Hat Channel Industrial Damper ID-141x 12-Gauge Hat Channel Industrial Damper Product Bulletin Code No. LIT-12011355 Issued June 12, 2013 Supersedes March 13, 2012 Since 1905, Johnson Controls has developed and refined air control products

More information

Automatic Roof Door Vents

Automatic Roof Door Vents DATA SHEET Automatic Roof Door Vents Features n UL Listed for use as an automatic smoke vent n FM Approved as an automatic door vent for use in high expansion foam systems n Available in multiple sizes

More information

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

CONTROL DAMPERS. Models 1810 & Model Model Model 1370 CONTROL DAMPERS CONTROL DAMPERS MODELS 1810 & 1820 MANUAL ALANCING DAMPERS STEEL Models 1810 and 1820 have been engineering and designed for manual balancing applications in low to medium pressure and

More information

Square Inline Fans with Multi-Directional Discharge

Square Inline Fans with Multi-Directional Discharge SQN Square Inline Fans with Multi-Directional Discharge Page Introduction............................................2 Standard Construction Features............................ 3 Specifications and Dimension

More information

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD The Industrial Choice. Model VB Direct Drive Model VBBD Belt Driven VANEAXIAL FANS Direct Drive & Belt Driven Model VB / VBBD BULLETIN 466 November 2000 Contents Construction Features Belt Driven... 3

More information

A X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S

A X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S A X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S Australia s leading fan company PRODUCT OVERVIEW COMMERCIAL INDUSTRIAL POWER & ENERGY MINING FOOD PROCESSING

More information

MICRO SEAL-SERIES HEPA Holding Frames and Housings

MICRO SEAL-SERIES HEPA Holding Frames and Housings MICRO SEAL-SERIES HEPA Holding Frames and Housings Three reliable retaining systems for absolute air filters Applications The AES Environmental HEPA filter retaining systems are used to accommodate Email

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4050 November 2009 DOWNBLAST ROOF EXHAUSTERS TYPE DCRD / BCRD (Spun Aluminum Housing) TYPE BCRD-E (Endurex Polymeric Housing) Downblast Roof Exhausters Twin City Fan & Blower

More information

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED ROOF VENTILATORS Models BSHD / BSHB CATALOG 632 November 12 Hooded Roof Ventilators Models BSHD BSHB Aerovent Low Profile Hooded Roof Ventilators

More information

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE BELT AND DIRECT DRIVE MODEL FEATURES Exhaust air up to 78,000 CFM in static pressure applications up to 1/2 w.g. Straight-through air flow design results in maximum exhaust efficiency Belt drives permit

More information

Fixed Pitch Vane Axial Fan

Fixed Pitch Vane Axial Fan Fixed Pitch Vane Axial Fan Page Introduction...........................................2 Construction Features...................................3 Mounting Options.......................................3

More information

TORIN by: AIRDEX Index Page No.

TORIN by: AIRDEX Index Page No. Index Page No. N Series Fans 2 Bladed, Heavy Duty...1 N Series Fans 3 Bladed, Free Air...2-3 N Series Fans 4 Bladed, Heavy Duty...4-5 Universal Hubs...6 One Piece Fan O Series 4 & 5 Bladed...7 One Piece

More information