Power Units. H-Pak & V-Pak. V-Pak Low Profile. Performance Data

Similar documents
Power Units. Page. (M) = Mobile (I) = Industrial (B) = Mobile & Industrial

Hydraulic Power Units D, H, V-Pak and V-Pak Low Profile Series

Hydraulic Power Units D, H, V-Pak and V-Pak Low Profile Series. HY CD/US Effective: July 01,

Hydraulic Power Units D, H, V-Pak and V-Pak Low Profile Series. HY CD/US Effective: Mar 31,

Hydraulic Power Units

Hydraulic Power Units

Motors & Pumps- Hydraulic Pumps, Motors & Power Units

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. Features. Application. Operation

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

D03, D05 & D08 SERIES

ZE3 & ZE4 Electric 1 & 1 1/2 HP Pump Series

Directional Control Valves. Application. Features. Operation

Directional Control Valves. Application. Features. Operation

Directional Control Valves. Application. Features. Operation.

Proportional Directional Valve System

Directional Control Valves. General Description. Operation. Features

550 Series Hydraulic Power Units. Pressures to 207 bar (3000 psi) Flows to 11.4 lpm (3 gpm)

Directional Control Valves. General Description. Operation. Features

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

MF100BH (BASIC HYDRAULICS TRAINER) PARTS LIST CATALOG APRIL 2013

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

03 SERIES. General Information Mounting Surface : ISO 4401-AC-05-4-A, CETOP-5, NFPA-DO2 Up to 25 MPa (3630 PSI), 70 L /min (18.5 U.S.

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Monobloc and Sectional Directional Control Valves

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

Direct Operated Proportional DC Valves

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Functional Symbols and Application Notes

Monobloc and Sectional Directional Control Valves

Bankable Control Valves

Directional Control Valves. Features. Application. Operation

Filtration Contamination class 10, according to NAS 1638 can be realized with filter ß = 75

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

5 Port Solenoid Valve

Directional Control Valves. Features. Application. Operation

SECTION TITLE HEC2003/2004 SERIES SERVO VALVE SYSTEM ACCESSORIES KEY FEATURES

5 Port Solenoid Valve

Operation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Control Valves

5 Port Solenoid Valve

Monobloc and Sectional Directional Control Valves

4/5 Port Solenoid Valve

2/2 ^ % ) Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

4/5 Port Solenoid Valve

Directional Control Valves

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

CMF2 Series Applicable cylinder bore size: Max. ø160

Monobloc and Sectional Directional Control Valves

385 & 962 Series The lectroaire valve is a compact, air operated, electrically lectroaire valves can be remotely mounted for control of double acting

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

Proportional Valves. Proportional Two-Stage Directional Valves

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Power units. Hydraulic power units. hydraulic hydraulic hydraulic. hydraulic hydraulic

Directional control valves catalogue NVD2 - NVS3

Monobloc and Sectional Directional Control Valves

Catalog Power Unit Accessories

APV Load Sensing Valve

VQ1000. How to Order Manifold. Kit type

Series VQZ1000/2000/3000 Single Unit

Air Valve AIR-PILOTED VALVES

Performance Information Series PVP 100/140 Pressure Compensated, Variable Volume, Piston Pumps

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

Temperature Sensors. How to Order Consult factory for pricing and lead time. Normally Open (Closed on temperature rise)

BST / BSG-03 / 06 / 10 Threaded Connections / Sub-plate Mounting. Specifications / Model Number Designation. Max. Flow L/min (U.S.GPM) Double Sol.

Filter/Cooler Module. Advantages: RA 50127/ /12 Replaces: Model MFC3, MFN3, MNC3

High Pressure, Subplate Mounted Directional Control Valves

250 bar P max. Technical Features. Functional Description

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Catalog Power Unit Accessories

Modular valves DO5 (NG 10) 315 bar

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

Eaton PVM Variable Displacement Piston Pumps Vickers Product Line cc 3 ( in 3 )

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

S21 Series. - 1" NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

5 Port Solenoid Valve

Functional Description HU /2012. Compact Hydraulic Power Packs USMA 05. Replaces HA /2008. p max 3600 PSI (250 bar) 4.

Load-Sensing Control Block SB12

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN>

Open center control block in mono block design MO-16, 22, 32

Servo directional valve of 4-way design Type 4WS.2E

S21 Series. - 2" NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight

Axial Piston Variable Pump A15VSO

MC HYDRAULIC POWER PACK

Portable Filter Carts Models 5MF and 10MF

RELIEF VALVES Remote Control / Direct Type Pilot Operated / Solenoid Controlled

Directional servo-valve in 4-way design

5.2 to 79 gpm 3000, 3600, 5000 psi

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

LMP screw pumps for delivery pressures up to 120 bar

2/2- or 3/2-way- Rocker Solenoid Valve

CS-SCB Sander Control Block Manual

ENGINEERING DATA. Quick Reference Chart. Variable Volume Vane Pumps Models SV-20 & SV-25 Flange & Subplate Mounted. Industrial Hydraulics

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

Series PHP10 Variable Volume, Piston Pumps

Transcription:

ower Units H-ak & V-ak H-ak and V-ak style power units are ideal for many industrial applications. These space saving vertical style units are available with gear or piston pumps and are designed for quiet and leak-free operation. Standard arker filtration on each unit will help ensure a long service life. lso available in V-ak Low rofile. V-ak Low rofile erformance Data Model Series Tank (Gal) ump, GM (LM) @ 1725 RM Electric Motor H (KW) Max. ressure SI (R) H-ak 10, 20, 30, 40 0.9-9.6 (2.2-36.3) 0.5-20 (0.37-14.9) 3000 (210) V-ak 10, 20, 30, 40 2.0-15.6 (7.6-59.1) 2-20 (1.4-14.9) 3000 (210) V-ak Low rofile 80 36.1 (136.7) 7.5-40 (5.6-30) 3000 (210) Markets Industrial resses, Shears, Test Equipment, Simulators pplications * Stainless units & other options available on request 145

T SFETY RELIEF D NT DJUST ower Units H-ak and V-ak E F Low rofile V-ak T VIEW G G UM CMENSTR CNTRL F UM RIME T 22.9 (.9) D FRNT VIEW * -D03 -D05 -D03 -D05 V-K C C D E Dimensions, inch (mm) Series H1/V1 H2/V2 H3/V3 H4/V4 V8 10.5 (267) to 16.3 (414) * 0.8 (19) 2.6 (67) 10.5 (267) to 19.3 (492) 0.8 (19) to 3.4 (85) 11.8 (298) to 19.3 (492) 0.8 (19) to 3.4 (85) 11.8 (298) to 19.3 (492) 0.8 (19) to 3.4 (85) 16.6 (451) to 24.7 (627) 1.88 (48) to 5.7 (144) C 15.4 (390) 19.4 (492) 23.6 (600) 28.9 (733) 28.6 (725) D 16.1 (410) 19.5 (495) 19.5 (495) 19.5 (495) 36.0 (914) E 19.0 (483) 22.5 (572) 22.5 (572) 22.5 (572) 39.0 (991) F 16.6 (422) 20.0 (508) 20.0 (508) 20.0 (508) 32.3 (819) G 16.6 (422) 20.0 (508) 20.0 (508) 20.0 (508) 34.6 (879) * Depending on motor option Reference dimensions consult factory if critical to application 146

ower Units H-ak Model rdering W Reservoir ressure ump No Motor (See Note) ** Electric Motor Manifold Reservoir Size Gallons (Liters) H1* 10 (37.9) H2 20 (75.7) H3 30 (113.6) H4 40 (151.4) *vailable up to 7.5 KW (10 H) motor only. J ressure * System ressure nly System ressure with Unloading Valve (2-Way 120VC) N.. (Energize coil to close) System ressure with Unloading Valve (2-Way 24VDC) N.. (Energize coil to close) 0.9 331-9110-267 1.3 331-9110-011 1.8 331-9110-010 2.7 331-9110-101 3.2 334-9111-069 4.5 334-9111-068 5.1 334-9111-067 6.3 334-9111-048 9.6 334-9111-065 ump Used U1*.5 (.37) - 1725-56C - 1 T1 1 (.75) - 1725-56C - 1 T3 1 (.75) - 1725-56C - 3 G 2 (1.5) - 1725-56C - 3 K 3 (2.2) - 1725-56C - 3 L 5 (37.5) - 1725-184TC - 3 M 7.5 (5.6) - 1725-213TC - 3 N 10 (7.5) - 1725-215TC - 3 15 (11.2) - 1725-254TC - 3 S 20 (14.9) - 1725-256TC - 3 Electric Motor Description H (KW) - RM - Frame - hase * U1 leadtime is 2 weeks Single phase electric motors are rated as follows: 115/230V, 1H, TEFC - 60 Hertz 1800 RM Three phase electric motors are rated as follows: 208-230/460V, 3H, TEFC - 60 Hertz 1800 RM Consult factory for other motor speeds (RM) and voltages. vailable with H2, H3 and H4 tanks only. ** Use W prefix when no motor is required on unit. When ordering, W must be followed by motor model code equivalent to frame size of motor to be used. S3 S5 M33 M35 M53 M55 orting lock/subplate or Manifold Type ressure and Return ort lock with Safety D03 Single Station Subplate with Safety D05 Single Station Subplate with Safety D03 Multistation arallel Circuit Manifold with Safety D05 Multistation arallel Circuit Manifold with Safety Supply/Return ort or ctuator ort Size & T orts SE-10 Str. Thr'd SE-10 Str. Thr'd ther Convertible to S3 ption Spare & T SE-10 orts Spare & T SE-12 orts Spare G ort SE-6 Spare G ort SE-6 Manifolds are mounted vertically. ottom station is number 1. 147

ower Units H-ak Model rdering Valve *Manapak ptions and ccessories Function NF Nominal GM (LM) D1VW001CN*** D03 7 (26.5) C D1VW004CN*** D03 7 (26.5) F D3W1CN** D05 20 (75.7) G D3W4CN** D05 15 (56.8) T D1VW008CN*** D03 7 (26.5) W D3W8CN** D05 15 (56.8) NF Nominal GM (LM) 1 FM2DDKN D03 7 (26.5) 2 FM3DDKN D05 12 (45.4) 3 ilot perator CM2DDN D03 7 (26.5) 4 ilot perator CM3DDN D05 12 (45.4) *Manapak valves mounted in order of callout. First valve will be nearest DCV; last valve will be on manifold. Description Units less valves wil be supplied with station cover plates installed. Circuit Symbol Function Model Technical Data 1* 2* Return Heat Return Heat RM-08-1-2 RM 190-1-2 H ressure Filter 15110QXRS K L R1 R2 Valve ump utlet ypass (on Heat Exch) Return Filter N.. Float Up Float Up "DT" & "C" Series C1220S65 12T10C 12 GM (45 LM) 876782-01 876782-02 ir/il:.7 H (0.52 kw), Rej. @ 7 GM (26.5 LM) 0.37-3.7 kw Motors only ir/il: 1.5 H (1.1 kw), Rej. @ 7 GM (26.5 LM) 5.6-11.2 kw Motors only Microglass II Element, Vis. Ind. - 50 SI (3.49 bar) ypass - 4 SI (0.27 bar), Diff. @ 7 GM (26.5 LM) 5 SI (0.34 bar) Cracking ressure 25 SI (1.72 bar) Diff. @ 15 GM (56.8 LM) (65 SI) 4.5 bar Cracking ressure Cellulose Element, Ind. Gage - 15 SI (1.03 bar) ypass Close @ Low Level and/or 65 C (149 F) (N..) pen @ Low Level and/or 65 C (149 F) (N.C.) *Heat rejection based on flow given with a 40 F differential between transfer medium. 148

ower Units V-ak Model rdering R Reduced W Reservoir ressure ump ump No Motor (See Note) ** Electric Motor Manifold Reservoir Size Gallons (Liters) V1* 10 (37.9) V2 20 (75.7) V3 30 (113.6) V4 40 (151.4) *vailable up to 10 H (7.5 kw) motor only. J C CJ D DJ F ressure Single ressure Remote Compensator Single ressure Remote Compensator with Low ressure Standby Single ressure Remote Compensator with Low ressure Standby, 24 VDC i-ressure Remote Compensator i-ressure Remote Compensator, 24VDC i-ressure Remote Compensator with Low ressure Standby i-ressure Remote Compensator with Low ressure Standby, 24VDC rovision for Customer Supplied Remote H** Horsepower Limiting *_SE-6 sense port line will be supplied in topplate. ** Horsepower setting will be at max. flow & pressure obtainable with motor selected. Lead time is four weeks for shaded items. ump Rate @1800 RM ump Std. Remote Compensator Load Sense ump Used and Description 7 7 GM (29.5 LM) V16 - Std. Remote Compensator * Specify in GM Destroked Max. Volume 2 GM Min. 15 15.6 GM (59 LM) V33 - Std. Remote Compensator ** Specify in GM Destroked Max. Volume 8 GM Min. *Unless otherwise specified, units are shipped at max. flow rate 7.8 GM (29.5 LM) at 1800 RM. When reduced flow setting is required, specify pump setting in.5 GM (1.9 LM) increments. Example: 5, 5.5, 6, 6.5 with a 2 GM (7.6 LM) minimum flow. **Unless otherwise specified, units are shipped at max. flow rate 15.6 GM (59 LM) at 1800 RM. When reduced flow setting is required, specify pump setting in.5 GM (1.9 LM) increments. Example: 11, 11.5, 12, 12.5 with a 8 GM (30.3 LM) minimum flow. Electric Motor Description H (KW) - RM - Frame - hase G 2 (1.5) - 1725-56C - 3 K 3 (2.2) - 1725-56C - 3 L 5 (37.5) - 1725-184TC - 3 M 7.5 (5.6) - 1725-213TC - 3 N 10 (7.5) - 1725-215TC - 3 15 (11.2) - 1725-254TC - 3 S 20 (14.9) - 1725-256TC - 3 Electric motors are 208-230/460V, 60 Hz 3H 1800 RM TEFC. Consult factory for other motor speeds (RM) and voltages. vailable with V2, V3 and V4 tanks only. ** Use W prefix when no motor is required on unit. When ordering, W must be followed by motor model code equivalent to frame size of motor to be used. S3 S5 M33 M35 M53 M55 orting lock/subplate or Manifold Type ressure and Return ort lock with Safety D03 Single Station Subplate with Safety D05 Single Station Subplate with Safety D03 Multistation arallel Circuit Manifold with Safety D05 Multistation arallel Circuit Manifold with Safety Supply/Return ort or ctuator ort Size & T orts SE-10 Str. Thr'd SE-10 Str. Thr'd Manifolds are mounted vertically. ottom station is number 1. ther Convertible to S3 ption Spare & T SE-10 orts Spare & T SE-12 orts Spare G ort SE-6 Spare G ort SE-6 Example: V*12**-- = Std. ump Destroked to 12 GM (45.4 LM) V*11.5**-- = Load Sense ump Destroked to 11.5 GM (43.5 LM) 149

ower Units V-ak Model rdering continued on next page Valve *Manapak ptions and ccessories 1 2 3 4 Valve Model Manapak Function ilot perator ilot perator NF Nominal GM (LM) D1VW001CN*** D03 7 (26.5) C D1VW004CN*** D03 7 (26.5) F D3W1CN** D05 20 (75.7) G D3W4CN** D05 15 (56.8) Units less valves wil be supplied with station cover plates installed. NF Nominal GM (LM) FM2DDKN D03 7 (26.5) FM3DDKN D05 12 (45.4) CM2DDN D03 7 (26.5) CM3DDN D05 12 (45.4) *Manapak valves mounted in order of callout. First valve will be nearest DCV; last valve will be on manifold. Description 1* 2* ptions and ccessories Function Model Technical Data ump Case Heat Return Heat Return Heat RM-08-4-2 RM-08-1-2 RM 190-1-2 H ressure Filter 15110QXRS K L Valve ump utlet ypass (on Heat Exch) "DT" & "C" Series C1220S65 N Return Filter 40CN110 R1 R2 Return Filter N.. Float Up Float Up 12T10C 12 GM (45 LM) 876782-01 876782-02 ir/il: 0.7 H (0.52 kw), Rej. @.5 GM (1.9 LM) 2-15 H (1.5-11.2 kw) Motors ir/il: 0.7 H (0.52 kw), Rej. @ 7 GM (26.5 LM) 2-5 H (1.5-3.7 kw) Motors only ir/il: 1.5 H (1.1 kw), Rej. @ 7 GM (26.5 LM) 7.5-15 H (5.6-11.2 kw) Motors only Microglass II Element, Vis. Ind. - 50 SI (3.49 bar) ypass - 4 SI (0.27 bar), Diff. @ 7 GM (26.5 LM) 5 SI (0.34 bar) Cracking ressure 25 SI (1.72 bar) Diff. @ 15 GM (56.8 LM) (65 SI) 4.5 bar Cracking ressure Microglass II Element, Visual 25 SI (1.72 bar) Indicator 3 SI (0.21 bar) Diff. @ 7 GM (26.5 LM) Cellulose Element, Ind. Gage - 15 SI (1.03 bar) ypass Close @ Low Level and/or 65 C (149 F) (N..) pen @ Low Level and/or 65 C (149 F) (N.C.) *Heat rejection based on flow given with a 40 F differential between transfer medium. 150

ower Units V-ak Model rdering V8 R Reduced W Reservoir Size 80 Gallons (302.8 Liters) ressure ump ump No Motor (See Note) ** Electric Motor Manifold J C CJ D DJ F ressure Single ressure Remote Compensator Single ressure Remote Compensator with Low ressure Standby Single ressure Remote Compensator with Low ressure Standby, 24 VDC i-ressure Remote Compensator i-ressure Remote Compensator, 24VDC i-ressure Remote Compensator with Low ressure Standby i-ressure Remote Compensator with Low ressure Standby, 24VDC rovision for Customer Supplied Remote Std. Remote Compensator Load Sense NTE: 1. Manifolds are mounted vertically. ottom station is number 1. 2. M5-3 and 5 station available. M8-2 station available. ump *Unless otherwise specified, a SE-6 37 flared port will be supplied for customer connection. **Consult factory for horsepower and hi-lo pump control options. Lead time is four weeks. ump Rate @1800 RM ump Used and Description 15 15.6 GM (59 LM) V33 - Std. Remote Compensator 23 23.0 GM (87 LM) V48 - Std. Remote Compensator 36 36.1 GM (137 LM) V76 - Std. Remote Compensator * Specify in GM Destroked (Reduced) *Unless otherwise specified, units are shipped at max. flow rate (GM) at 1800 RM. When reduced flow setting is required, Reduced flows from 22.5 to 8.0 GM (85.2 to 30.3 LM), specify in 0.5 GM increments. Reduced flows from 35.0 to 24.0 GM (132.5 to 90.8 LM), specify in 1.0 GM (3.8 LM) increments. Example: V*9.5**-- V*31**-- = V33 ump destroked to 9.5 GM (36.0 LM) = V76 Load Sense ump destroked to 31.0 GM (177.3 LM) M N S Q R V Electric Motor Description H (kw) - RM - Frame - Type 7.5 (5.6) - 1800-213TC - TEFC 10 (7.5) - 1800-215TC - TEFC 15 (11.2) - 1800-254TC - TEFC 20 (14.9) - 1800-256TC - TEFC 25 (18.6) - 1800-284TC - TEFC 30 (22.4) - 1800-286T - TEFC 40 (29.8) - 1800-324T - TEFC Electric motors are 230/460V, 60 Hz 3H. Consult factory for other motor speeds (RM) and voltages. **Use W prefix when no motor is required on unit. When ordering, W must be followed by motor model code equivalent to frame size of motor to be used. Example: V815WM*** = 302.8 L (80 gal) reservoir, std V33 unit to accept a 7.5 H (5.6KW)/213TC C-face frame motor. S5 orting lock/subplate or Manifold Type ressure and Return ort lock with Safety D05 Single Station Subplate with Safety D05 Multistation arallel Circuit Manifold with Safety M5* (2) Relief and ump Compensator M82 (3) D08 Two arallel Circuit Manifold with Safety Relief and ump Compensator Supply/Return ort or ctuator ort Size ort SE-16 T ort SE-20 SE-10 Str. Thr'd SE-16 Str. Thr'd ther None None None Y ort SE-8 Str. Thr'd *When ordering Multi-Station Manifolds, the number of stations must be specified. If valves are to be mounted, specify the valves and sequence, if the model code exceeds 25 digits, call factory. Example: V815QM53C1 Example: V815QM5511CC 3 Station D05 Manifold 5-Station D05 Manifold Station #1: Station #1: 1 Station #2: C Station #3: 1 Station #2: 1 Station #3: C Station #4: Station #5: C 151

ower Units V-ak Model rdering Valve *Manapak ptions and ccessories Valve NF Nominal GM (LM) D1VW001CN*** D03 7 (26.5) C D1VW004CN*** D03 7 (26.5) Description 1 3 Manapak Function ilot perator NF FM2DDKN D03 7 (26.5) CM2DDN D03 7 (26.5) *Manapak valves mounted in order of callout. First valve will be nearest DCV; last valve will be on manifold. Nominal GM (LM) * ptions and ccessories Function Model Technical Data Continuous ump Case Cooling Continuous ump Case Cooling C* Filter/Cooling Loop RM-08-2-2 RM-19-2-2 CC-22-2-1H 40CN205Q H ressure Filter 210QM250NN1 ir/il: Max. il 4.5 GM (17 LM), 0.8 H (0.6 kw) Heat Rejection ir/il: Max. il 4.5 GM (17 LM) 1.5 H (1.1 kw) Heat Rejection ir il w/1 H Motor: il 4.5 GM (17 LM), 4.5 H (3.3 kw) Heat Rejection 10 Micron Microglass II Dual Element, Mechanical Indicator K Valve ump utlet 493-16-D1-2 5 SI (0.3 bar) Cracking ressure L ypass C2020S65 65 SI (4.6 bar) Cracking ressure N Return Filter 40CN210Q 10 Micron Microglass II Dual Element, Mechanical Indicator** (8 SID) QS Return Filter 80CN110QE2GS24-4 10 Micron Microglass II Single Element Electrical Indicator (25 SI) R1 R2 N.. Float Up N.C. Float Up 877501 877502 Close @ Low Level and/or 65 C (149 F) (N..) pen @ Low Level and/or 65 C (149 F) (N.C.) *Heat rejection data is based on 100 SSU oil leaving the cooler 22 C (72 F) higher than the ambient air temperature used for cooling. ption available from 7.5 H (0.6 KW) thru 25 H (18.5 KW). ption C not available with option or. **ased on max. 36 GM (136 LM) w/150 SUS oil. 152