DIRECT FIRED ABSORPTION CHILLER & HEATER

Size: px
Start display at page:

Download "DIRECT FIRED ABSORPTION CHILLER & HEATER"

Transcription

1 DIRECT FIRED ABSORPTION CHILLER & HEATER MODEL : SAB-DF012~070E1 SAB-DF012~100G1. CHP Solution Inc

2 Excellent Performance with More Energy Savings, Excellent Efficiency iency at Much Lower Cost. At Cention, basing ourselves on cooling technology and know-how acquired over many years, we put into practice our latest proprietary technology. Through the use of large chilled /cooling temperature differential adaptability and provision of a high-functionality microcomputer as a standard control panel, superior reliability and durability are realized, while achieving running efficiency. As an item of new-age cooling equipment Cention s one step advanced chiller contributes to the realization of total energy-saving and low cost in air-conditioning system. Low Energy and Low Cost -By means of the new cooling flow system (ACA flow), a standard frame size accommodating large chilled /cooling temperature differential is realized. By improvement of control of solution circulating quantity, a 10% improvement in average load factor is achieved in partial load characteristics. High Reliability -A high functionality microcomputer control panel with a complete set of preventive maintenance and abnormality forecast functions is a standard feature. Standard cooling capability realizing up to 4,000 hrs/yr operation. Superior Operability and Easy Maintenance -Operating condition or abnormalities are quickly shown on easy-to-see liquid crystal digital and LED displays. Full automation of purging operation is realized by use of ejector purging device which does not use electricity and can purge out any non-condensed gases. Compatible with air conditioning system interfaces and supports introduction of remote supervision system. Large-Temperature Temperature-Differential System. -By using the large-temperature-differential system, the circulating volumes of chilled and cooling can be reduced. The large-temperature-differential system reduces needed for circulating air and, because of reduced volumes of the draught from the air conditioner fan and of the circulating from the chilled and cooling pumps. In addition, it makes such facilities as air ducts and chilled/cooling pipes smaller, and also reduces the initial cost for them.

3 Efficiency Operation. -In addition to the parallel flow system, Cention's new proprietary flow technology (ACA flow technology) is employed in the cooling system. Without increasing the chiller frame size, the adaptation to large chilled/cooling temperature differentials has been made possible. Accordingly, energy-saving and low operating cost (by reduction of start-up and other operating costs) are achieved not only for the chiller but for airconditioning as well. High Performance Microcomputer. -Electric saving with large-temperature differential chilled/cooling system. Stable and reliable operation with crystallization free In the parallel flow system, the diluted solution coming out of the absorber is divided into two flows. These two flows of solution are sent to the high-temperature and low-temperature generators separately. The system holds the flow of the high-temperature generator lower than the series flow(indicated by in the figure), while keeping an enough margin for crystallization in a low-temperature condition (indicated by in the figure). In addition, the performance of absorption cycle is increased because the rate of solution flow into the high-temperature generator is made lower than that of series flow.

4 Specifications 1) High Efficiency Specifications (COP 1.32~1.35 MODEL) Item Chilled Cooling Standard condition(12-7 / )(COP 1.32) SAB-DF 012E1 015E1 018E1 021E1 024E1 028E1 032E1 USRT kw ,125 Mcal/h kw ,000 Temperature Inlet 12 Outlet 7 Flow rate /h PD kpa Connection A PASS - Odd Odd Odd Even Even Odd Odd Temperature Inlet 32 Outlet 37 Flow rate /h PD kpa Connection A PASS - Odd Odd Odd Even Even Odd Odd Inlet temp Outlet temp Flow rate /h PD kpa Connection A Electric capacity Electric motor Gas consumption PASS - Odd Odd Odd Even Even Odd Odd 50Hz kva Hz kva Sol. Pump kw (2.2) (2.2) Ref. Pump kw Burner fan kw Cooling N /h Heating N /h Input supply mmaq 200~4000 Exhaust gas connection mm 266X X X364 dimensions Length(L) mm 3,353 3,408 3,791 4,591 Width(W) mm 1,955 1,955 1,955 1,955 Height(H) mm 2,419 2,419 2,419 2,419 Operating weight Ton Rigging weight Ton Insulation area Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM

5 Item Chilled Cooling Electric capacity Gas consumption Standard condition(12-7 / )(COP 1.32) Cooling tower type SCTM NOTES 1.(1 USRT) is 3,516 kw(3,024 kcal/h) 7. Inlet of chilled/hot/cooling are all A side 2. Fouling factor (chilled/hot/cooling ) is Outlet is B side for Odd PASS and A side for Even PASS K/W( h /kcal) 8. If supply of 13A is 98kpa, Combustion system should be changed 3. Maximum permissible for chilled/hot/cooling 9. Dimension of gas pipe is changed by gas supply is 780 kpa G(8 kg/ G). or operation of remote on/off 4. control range for Standard specification (Capacity, chilled/cooling ) in cooling mode is 100~25%. 5. Caloric value of 13A gas is 46 MJ/ N(11,000 kcal/ N). 6. Exhaust gas of NO X is 45 ppm(o 2=5%) SAB-DF 036E1 040E1 045E1 050E1 056E1 063E1 070E1 USRT kw 1,266 1,407 1,582 1,758 1,969 2,215 2,461 Mcal/h 1,001 1,110 1,252 1,387 1,490 1,665 1,947 kw 1,164 1,291 1,456 1,613 1,733 1,936 2,264 Temperature Inlet 12 Outlet 7 Flow rate /h PD kpa Connection A PASS - Odd Odd Odd Odd Even Even Even Temperature Inlet 32 Outlet 37 Flow rate /h PD kpa Connection A PASS - Odd Even Odd Odd Even Even Even Temperature Inlet 55.4 Outlet / / 60 Flow rate /h PD kpa Connection A PASS - Odd Odd Odd Odd Even Even Even 50Hz kva Hz kva Sol. Pump kw Ref. Pump kw Burner fan kw Input Cooling N /h Heating N /h supply mmaq 200 ~ 4,000 Exhaust gas connection mm 440X X X X788 Length(L) mm 5, X656 5,807 7,183 7,883 dimensions Width(W) mm 2,131 2,395 2,468 2,468 Height(H) mm 3,102 3,102 3,102 3,102 Insulation area Operating weight Ton Rigging weight Ton Hot Surface Cold Surface Chilled Cooling

6 Large temperature differentials condition(15-7 / ) (COP 1.35) Item SAB-DF 012EA 015EA 018EA 021EA 024EA 028EA 032EA USRT kw ,125 Mcal/h kw ,000 Temperature Inlet 15 Outlet 7 Flow rate /h Chilled PD kpa Connection A PASS - Odd Odd Odd Even Even Even Even Temperature Inlet 32 Outlet 37 Flow rate /h Cooling PD kpa Connection A PASS - Odd Odd Odd Even Even Odd Odd Inlet Temp Outlet Temp Flow rate /h PD kpa Connection A PASS - Odd Odd Odd Even Even Even Even Electric capacity Gas consumption 50Hz kva Hz kva Sol. Pump kw (2.2) (2.2) Ref. Pump kw Burner fan kw Cooling N /h Heating N /h Input supply mmaq 200~4,000 Exhaust gas connection mm 266X X X364 dimensions Length(L) mm 3,353 3,408 3,791 4,591 Width(W) mm 1,955 1,955 1,955 1,955 Height(H) mm 2,419 2,419 2,419 2,419 Operating weight Ton Rigging weight Ton Insulation area Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM

7 Large temperature differentials condition(15-7 / ) (COP 1.35) SAB-DF Item 036EA 040EA 045EA 050EA 056EA 063EA 070EA USRT kw 1,266 1,407 1,582 1,758 1,969 2,215 2,461 Mcal/h 1,001 1,110 1,252 1,387 1,490 1,665 1,947 kw 1,164 1,291 1,456 1,613 1,733 1,936 2,264 Temperature Inlet 15 Outlet 7 Flow rate /h Chilled PD kpa Connection A PASS - Even Even Even Even Odd Odd Odd Temperature Inlet 32 Outlet 37 Flow rate /h Cooling PD kpa Connection A PASS - Odd Even Odd Odd Even Even Even Temperature / / / / / / / 60 Flow rate /h Electric capacity PD kpa Connection A PASS - Even Even Even Even Odd Odd Odd 50Hz kva Hz kva Sol. Pump kw Ref. Pump kw Burner fan kw Cooling N /h Gas consumption Heating N /h Input supply mmaq 200 ~ 4,000 Exhaust gas connection mm 440X X X X788 Length(L) mm 5,034 5,807 7,183 7,883 Width(W) mm 2,131 2,395 2,468 2,468 Height(H) mm 3,102 3,102 3,102 3,102 Operating weight Ton Rigging weight Ton Insulation area Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM NOTES 1.(1 USRT) is 3,516 kw(3,024 kcal/h) 7. Inlet of chilled/hot/cooling are all A side 2. Fouling factor (chilled/hot/cooling ) is Outlet is B side for Odd PASS and A side for Even PASS K/W( h /kcal) 8. If supply of 13A is 98kpa, Combustion system should be changed 3. Maximum permissible for chilled/hot/cooling 9. Dimension of gas pipe is changed by gas supply is 780 kpa G(8 kg/ G). or operation of remote on/off 4. control range for Standard specification (Capacity, 10. If you use the oil fuel(light oil), combustion system should be changed chilled/cooling ) in cooling mode is 100~25%. from over 360RT. 5. Caloric value of 13A gas is 46 MJ/ N(11,000 kcal/ N). 6. Exhaust gas of NO X is 45 ppm(o 2=5%)

8 2) Standard Efficiency Specifications (COP 1.2 MODEL) Standard condition (12-7 /32-37 ) Item SAB-DF 012G1 015G1 018G1 021G1 024G1 028G1 032G1 USRT kw ,125 Mcal/h kw ,000 Temperature Inlet 12 Outlet 7 Flow rate /h Chilled Pressure kpa Connection A PASS - Even Even Odd Even Even Odd Odd Temperature Inlet 32 Outlet 37 Flow rate /h Cooling Pressure kpa Connection A PASS - Odd Even Odd Even Even Odd Odd Temperature Inlet 55.4 Outlet 60 Inlet 55.6, Outlet 60 Flow rate /h Pressure kpa Connection A PASS - Even Even Odd Even Even Odd Odd Electric capacity 50Hz kva Hz kva Sol. Pump kw Ref. Pump kw Burner fan kw Cooling N /h Gas Heating consumption N /h Input supply mmaq 200~4,000 Exhaust gas connection mm 440X X X436 Length(L) mm 3,350 3,590 3,790 4,150 4,410 4,950 4,950 Width(W) mm 1,925 1,925 1,925 1,925 1,925 1,988 1,988 Height(H) mm 2,170 2,170 2,170 2,170 2,170 2,248 2,248 Operating weight Ton Rigging weight Ton Insulation area Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM

9 Item Chilled Cooling Electric capacity SAB-DF Standard condition (12-7 / ) 036G1 040G1 045G1 050G1 056G1 060G1 070G1 USRT kw 1,266 1,407 1,582 1,758 1,969 2,110 2,461 Mcal/h 1,110 1,110 1,387 1,387 1,665 1,665 1,947 kw 1,291 1,291 1,613 1,613 1,936 1,936 2,264 Temperature Inlet 12 Outlet 7 Flow rate /h PD kpa Connection A PASS - Odd Odd Odd Odd Even Even Even Temperature Inlet 32 Outlet 37.3 Flow rate /h Pressure kpa Connection A PASS - Odd Odd Odd Odd Odd Odd Odd Temperature 54.9/ / / / / / /60 Flow rate /h PD kpa Connection A PASS - Odd Odd Odd Odd Even Even Even 50Hz kva Hz kva Sol. Pump kw Ref. Pump kw Burner fan kw Cooling N /h Gas Heating consumption N /h (13A Input supply mmaq 200~10,000 Exhaust gas connection mm 440X436 10, X X788 Insulation area Length(L) mm 5,150 5,150 5,920 6,100 Width(W) mm 2,440 2,480 2,550 3,350 Height(H) mm 2,650 2,940 3,040 3,480 Operating weight Ton Rigging weight Ton Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM NOTES 1.(1 USRT) is 3,516 kw(3,024 kcal/h) 7. Inlet of chilled/hot/cooling are all A side 2. Fouling factor (chilled/hot/cooling ) is Outlet is B side for Odd PASS and A side for Even PASS K/W( h /kcal) 8. If supply of 13A is 98kpa, Combustion system should be changed 3. Maximum permissible for chilled/hot/cooling 9. Dimension of gas pipe is changed by gas supply is 780 kpa G(8 kg/ G). or operation of remote on/off control 4. control range for Standard specification (Capacity, chilled/cooling ) in cooling mode is 100~25%. 5. Caloric value of 13A gas is 46 MJ/ N(11,000 kcal/ N). 6. Exhaust gas of NO X is 45 ppm(o 2=5%)

10 Standard condition (12-7 / ) Item 080G1 090G1 100G1 SAB-DF USRT ,000 kw 2,813 3,165 3,516 Mcal/h 2,318 2,318 2,800 kw 2,695 2,695 3,256 Temperature Inlet 12 Outlet 7 Flow rate /h Chilled PD kpa Connection A PASS - Even Even Even Temperature 32 / / 37.9 Flow rate /h Cooling PD kpa Connection A PASS - Odd Odd Odd Temperature 55.2/ / /60 Flow rate /h PD kpa Connection A PASS - Even Even Even Electric capacity Gas consumption 50Hz kva Hz kva Sol. Pump kw Ref. Pump kw Burner fan kw Cooling N /h Heating N /h Input supply mmaq 200~10,000 Exhaust gas connection mm 440x x1096 Length(L) mm 6,400 7,250 Width(W) mm 3,350 3,350 Height(H) mm 3,480 3,480 Operating weight Ton Rigging weight Ton Insulation area Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM 1,200 1,400 1,600

11 Large temperature differentials condition(15-7 / ) Item SAB-DF 012GA 015GA 018GA 021GA 024GA 028GA 032GA USRT kw ,125 Mcal/h kw ,000 Temperature Inlet 15 Outlet 7 Flow rate /h Chilled PD kpa Connection A PASS - Even Even Odd Odd Odd Even Even Temperature Inlet 32 Outlet 37 Flow rate /h Cooling PD kpa Connection A PASS - Odd Even Odd Even Even Odd Odd Temperature 52.7 / / / / / / / 60 Flow rate /h PD kpa Connection A PASS - Even Even Odd Odd Odd Even Even Electric capacity Gas consumption 50Hz kva Hz kva Sol. Pump kw Ref. Pump kw Burner fan kw Cooling N /h Heating N /h Input supply mmaq 200~4,000 Exhaust gas connection mm 440X X X436 Length(L) mm 3,350 3,590 3,790 4,150 4,410 4,950 4,950 Width(W) mm 1,925 1,925 1,925 1,925 1,925 1,988 1,988 Height(H) mm 2,170 2,170 2,170 2,170 2,170 2,248 2,248 Operating weight Ton Rigging weight Ton Insulation area Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM

12 Item Chilled Cooling Electric capacity Large temperature differentials condition(15-7 / ) SAB-DF 036GA 040GA 045GA 050GA 056GA 060GA 070GA USRT kw 1,266 1,407 1,582 1,758 1,969 2,110 2,461 Mcal/h 1,110 1,110 1,387 1,387 1,665 1,665 1,947 kw 1,291 1,291 1,613 1,613 1,936 1,936 2,264 Temperature Inlet 15 Outlet 7 Flow rate /h PD kpa Connection A PASS - Even Even Even Even Odd Odd Odd Temperature Inlet 32 Outlet 37.3 Flow rate /h PD kpa Connection A PASS - Odd Odd Odd Odd Odd Odd Odd Temperature 51.8/ / / / / / /60 Flow rate /h PD kpa Connection A PASS - Even Even Even Even Odd Odd Odd 50Hz kva Hz kva Sol. Pump kw Ref. Pump kw Burner fan kw Cooling N /h Gas Heating consumption N /h Input supply mmaq 200~10,000 Exhaust gas connection mm 440X436 10, X X788 Insulation area Length(L) mm 5,150 5,150 5,920 6,100 Width(W) mm 2,440 2,480 2,550 3,350 Height(H) mm 2,650 2,940 3,040 3,480 Operating weight Ton Rigging weight Ton Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM NOTES 1.(1 USRT) is 3,516 kw(3,024 kcal/h) 7. Inlet of chilled/hot/cooling are all A side 2. Fouling factor (chilled/hot/cooling ) is Outlet is B side for Odd PASS and A side for Even PASS K/W( h /kcal) 8. If supply of 13A is 98kpa, Combustion system should be changed 3. Maximum permissible for chilled/hot/cooling 9. Dimension of gas pipe is changed by gas supply is 780 kpa G(8 kg/ G). or operation of remote on/off 4. control range for Standard specification (Capacity, chilled/cooling ) in cooling mode is 100~25%. 5. Caloric value of 13A gas is 46 MJ/ N(11,000 kcal/ N). 6. Exhaust gas of NO X is 45 ppm(o 2=5%)

13 Large temperature differentials condition(15-7 / ) Item 080GA 090GA 100GA SAB-DF USRT kw Mcal/h kw Temperature Inlet 15 Outlet 7 Flow rate /h Chilled PD kpa Connection A PASS - Odd Odd Odd Temperature 32 / / 37.9 Flow rate /h Cooling PD kpa Connection A PASS - Odd Odd Odd Temperature 55.2/ / /60 Flow rate /h PD kpa Connection A PASS - Odd Odd Odd Electric capacity Gas consumption 50Hz kva Hz kva Sol. Pump kw Ref. Pump kw Burner fan kw Cooling N /h Heating N /h Input supply mmaq 200~10,000 Exhaust gas connection mm 440x x1096 Length(L) mm 6,400 7,250 Width(W) mm 3,350 3,350 Height(H) mm 3,480 3,480 Operating weight Ton Rigging weight Ton Insulation area Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM 1,200 1,400 1,600

14 3) Heating Increase Specifications(120~900RT COP 1.2 MODEL) Heating increase Standard condition(12-7 /32-37 ) SAB-DH Item 012G0 015G0 018G0 021G0 024G0 028G0 032G0 USRT kw ,125 Mcal/h ,110 1,110 kw ,000 1,291 1,291 Temperature Inlet 12 Outlet 7 Flow rate /h Chilled PD kpa Connection A PASS - Even Even Odd Even Even Odd Odd Temperature Inlet 32 Outlet 37 Flow rate /h Cooling PD kpa Connection A PASS - Odd Even Odd Even Even Odd Odd Temperature 54.1/ / / / / / /60 Flow rate /h PD kpa Connection A PASS - Even Even Odd Even Even Odd Odd Electric capacity 50Hz kva Hz kva Sol. Pump kw Ref. Pump kw Burner fan kw Gas Cooling N /h consumption Heating N /h Input supply mmaq 200~4,000 Exhaust gas connection mm 440X X X436 Length(L) mm 3,350 3,590 3,790 4,150 4,410 4,950 4,950 Width(W) mm 1,925 1,925 1,925 1,925 1,925 1,988 1,988 Height(H) mm 2,170 2,170 2,170 2,170 2,170 2,248 2,248 Operating weight Ton Rigging weight Ton Insulation area Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM

15 Item Chilled Cooling Electric capacity Gas consumption Heating increase Standard condition (12-7 /32 / ) SAB-DH 036G0 040G0 045G0 050G0 056G0 060G0 070G0 USRT kw 1,266 1,407 1,582 1,758 1,969 2,110 2,461 Mcal/h 1,387 1,387 1,665 1,665 1,947 1,947 2,318 kw 1,613 1,613 1,936 1,936 2,264 2,264 2,695 Temperature Inlet 12 Outlet 7 Flow rate /h PD kpa Connection A PASS - Odd Odd Odd Odd Even Even Even Temperature Inlet 32 Outlet 37.3 Flow rate /h PD kpa Connection A PASS - Odd Odd Odd Odd Odd Odd Odd Temperature 53.6/ / / / / / /60 Flow rate /h PD kpa Connection A PASS - Odd Odd Odd Odd Even Even Even 50Hz kva Hz kva Sol. Pump kw Ref. Pump kw Burner fan kw Input Cooling N /h Heating N /h supply mmaq 200 ~ 10,000 Exhaust gas connection mm 440X X X788 Insulation area Length(L) mm 5,150 5,150 5,920 6,100 Width(W) mm 2,440 2,480 2,550 3,350 Height(H) mm 2,650 2,940 3,040 3,480 Operating weight Ton Rigging weight Ton Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM NOTES 1.(1 USRT) is 3,516 kw(3,024 kcal/h) 7. Inlet of chilled/hot/cooling are all A side 2. Fouling factor (chilled/hot/cooling ) is Outlet is B side for Odd PASS and A side for Even PASS K/W( h /kcal) 8. If supply of 13A is 98kpa, Combustion system should be changed 3. Maximum permissible for chilled/hot/cooling 9. Heating increase standard condition is just raising the heating calorie. is 780 kpa G(8 kg/ G). 10. Hot generator is changed for heating increase standard condition therefore 4. control range for Standard specification (Capacity, should check connection between the burner and the combustion system. chilled/cooling ) in cooling mode is 100~25%. 5. Caloric value of 13A gas is 46 MJ/ N(11,000 kcal/ N). 6. Exhaust gas of NO X is 45 ppm(o 2=5%)

16 Heating increase Standard condition (12-7 / ) Item 080G0 090G0 SAB-DH USRT kw Mcal/h kw Temperature Inlet 12 Outlet 7 Flow rate /h Chilled PD kpa Connection A PASS - Even Even Temperature 32 / / 37.9 Flow rate /h Cooling PD kpa Connection A PASS - Odd Odd Temperature 54.2 / / 60 Flow rate /h PD kpa Connection A PASS - Even Even Electric capacity 50Hz kva Hz kva Sol. Pump kw Ref. Pump kw Burner fan kw Cooling N /h Gas consumption Heating N /h Input supply mmaq 10,000 Exhaust gas connection mm 440x x1096 Length(L) mm 6,400 7,250 Width(W) mm 3,350 3,350 Height(H) mm 3,480 3,480 Operating weight Ton Rigging weight Ton Insulating area Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM 1,200 1,400

17 Item Heating increase Large temperature differentials condition (15-7 /32-37 ) SAB-DH 012GA 015GA 018GA 021GA 024GA 028GA 032GA USRT kw ,125 Mcal/h ,110 1,110 kw ,000 1,291 1,291 Temperature Inlet 15 Outlet 7 Flow rate /h Chilled PD kpa Connection A PASS - Even Even Odd Odd Odd Even Even Temperature Inlet 32 Outlet 37 Flow rate /h Cooling PD kpa Connection A PASS - Odd Even Odd Even Even Odd Odd Temperature 50.5/ / / / / / /60 Flow rate /h PD kpa Connection A PASS - Even Even Odd Odd Odd Even Even Electric capacity 50Hz kva Hz kva Sol. Pump kw Ref. Pump kw Burner fan kw Cooling N /h Gas consumption Heating N /h Input supply mmaq 200~4,000 Exhaust gas connection mm 440X X X436 Length(L) mm 3,350 3,590 3,790 4,150 4,410 4,950 4,950 Width(W) mm 1,925 1,925 1,925 1,925 1,925 1,988 1,988 Height(H) mm 2,170 2,170 2,170 2,170 2,170 2,248 2,248 Operating weight Ton Rigging weight Ton Insulating area Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM

18 Item Chilled Cooling Electric capacity Gas consumption Heating increase Large temperature differentials condition (15-7 /32 / ) SAB-DH 036GA 040GA 045GA 050GA 056GA 060GA 070GA USRT kw 1,266 1,407 1,582 1,758 1,969 2,110 2,461 Mcal/h 1,387 1,387 1,665 1,665 1,947 1,947 2,318 kw 1,613 1,613 1,936 1,936 2,264 2,264 2,695 Temperature Inlet 15 Outlet 7 Flow rate /h PD kpa Connection A PASS - Even Even Even Even Odd Odd Odd Temperature Inlet 32 Outlet 37.3 Flow rate /h PD kpa Connection A PASS - Odd Odd Odd Odd Odd Odd Odd Temperature 49.8/ / / / / / /60 Flow rate /h PD kpa Connection A PASS - Even Even Even Even Odd Odd Odd 50Hz kva Hz kva Sol. Pump kw Ref. Pump kw Burner fan kw Input Cooling N /h Heating N /h supply mmaq 200~10,000 Exhaust gas connection mm 440X X X788 Insulating area Length(L) mm 5,150 5,150 5,920 6,100 Width(W) mm 2,440 2,480 2,550 3,350 Height(H) mm 2,650 2,940 3,040 3,480 Operating weight Ton Rigging weight Ton Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM NOTES 1.(1 USRT) is 3,516 kw(3,024 kcal/h) 7. Inlet of chilled/hot/cooling are all A side 2. Fouling factor (chilled/hot/cooling ) is Outlet is B side for Odd PASS and A side for Even PASS K/W( h /kcal) 8. If supply of 13A is 98kpa, Combustion system should be changed 3. Maximum permissible for chilled/hot/cooling 9. Heating increase standard condition is just raising the heating calorie. is 780 kpa G(8 kg/ G). 10. Hot generator is changed for heating increase standard condition therefore 4. control range for Standard specification (Capacity, should check connection between the burner and the combustion system. chilled/cooling ) in cooling mode is 100~25%. 5. Caloric value of 13A gas is 46 MJ/ N(11,000 kcal/ N). 6. Exhaust gas of NO X is 45 ppm(o 2=5%)

19 Heating increase Large temperature differentials condition (15-7 / ) Item 080GA 090GA SAB-DH USRT kw 2,813 3,165 Mcal/h 2,800 2,800 kw 3,256 3,256 Temperature Inlet 15 Outlet 7 Flow rate /h Chilled PD kpa Connection A PASS - Even Even Temperature 32 / / 37.9 Flow rate /h Cooling PD kpa Connection A PASS - Odd Odd Temperature 50.7 / / 60 Flow rate /h PD kpa Connection A PASS - Even Even Electric capacity 50Hz kva Hz kva Sol. Pump kw Ref. Pump kw Burner fan kw Cooling N /h Gas consumption Heating N /h Input supply mmaq 200~10,000 Exhaust gas connection mm 440x x1096 Length(L) mm 6,400 7,250 Width(W) mm 3,350 3,350 Height(H) mm 3,480 3,480 Operating weight Ton Rigging weight Ton Insulating area Hot Surface Cold Surface Chilled Cooling Cooling tower type SCTM 1,200 1,400

20 External dimensions Please refer to the specifications in p.4-7 for actual dimensions values of each model. Directions of outlet nozzle is on side B when the number of passes is odd number and on side A when it is even number above drawings. High efficiency E-series E MODEL 012E1/ 015E1 018E1 021E1/ 024E1 028E1/ 032E1 036E1/ 040E1 045E1/ 050E1 056E1/ 063E1 070E1 L 3,353 3,408 3,791 4,591 5,034 5,807 6,807 7,807 W 1,955 1,955 1,955 1,955 2,068 2,131 2,391 2,464 H 2,419 2,419 2,419 2,419 3,102 3,102 3,222 3,260 HIgh efficiency G-series G MODEL 012G1/ 015G1 018G1 021G1/ 024G1 028G1/ 032G1 036G1/ 040G1 045G1/ 050G1 056G1/ 063G1 070G1/ 080G1 090G1/ 100G1 L 3,350/3,590 3,790 4,150/4,410 4,950 5,150 5,150 5,920 6,100/6,400 7,250 W 1,925 1,925 1,925 1,988 2,440 2,480 2,550 3,350 3,350 H 2,170 2,170 2,170 2,248 2,650 2,940 3,040 3,480 3,480

21 Foundation & Maintenance space dimensions G-Series High efficiency G-series (A~K) A B C D E F G H I J K 012E , ,065 2, E , ,065 2, E , ,065 3, E , , ,065 3, E , , ,065 3, E1 1,060 2, , ,128 4, E1 1,060 2, , ,128 4, High efficiency G-series (A ~F ~F ) A B C D E F 012E1 2,400 1,410 2,200 1,412 2,065 2, E1 2,400 1,410 2,200 1,412 2,065 2, E1 3,000 1,960 2,800 1,412 2,065 3, E1 3,600 2,100 3,910 1,412 2,065 3, E1 3,600 2,100 3,910 1,412 2,065 3, E1 4,720 2,834 4,460 1,412 2,128 4, E1 4,720 2,834 4,460 1,412 2,128 4,200

22 High efficiency E-series E (A~K) A B C D E F G I J K 036E , , ,431 2,231 4,790 4, E , , ,431 2,231 4,790 4, E , ,470 1,170 2,695 2,495 5,790 5, E , ,470 1,170 2,695 2,495 5,790 5, E , ,677 2,653 1,540 2,768 2,568 7,090 7, E , ,677 2,653 1,540 2,768 2,568 7,090 7, E , ,677 2,953 1,940 2,768 2,568 7,790 7,990 High efficiency E-series E (A ~I ~I ) A B C D E F G H I 036E1 4,500 3,570 4, , ,231 4, E1 4,500 3,570 4, , ,231 4, E1 5,500 4,570 5, , ,495 5, E1 5,500 4,570 5, , ,495 5, E1 6,900 5,870 6, , ,568 7, E1 6,900 5,870 6, , ,568 7, E1 7,600 6,570 7, , ,568 7,790 Distributed by CHP Solution Inc. located at 333 Sylvan Avenue Suite 211, Englewood Cliffs, NJ USA ; info@centioncorp.com

Kawasaki turbo chiller using water as a refrigerant. Feb. 4 th 2015 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

Kawasaki turbo chiller using water as a refrigerant. Feb. 4 th 2015 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto Kawasaki turbo chiller using water as a refrigerant Feb. 4 th 2015 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto Contents 1. Background 2. Introduction of Kawasaki turbo chiller using

More information

CONTINUOUS CAPACITY CONTROL MODELS

CONTINUOUS CAPACITY CONTROL MODELS This series of air-cooled water chillers up to 400HP has been developed for various requirements of air conditioning systems and industrial chilled water systems, where these equipments are operated under

More information

Air Cooled Single Screw Chiller/ Heat Pump

Air Cooled Single Screw Chiller/ Heat Pump Technical Manual MHS - F - 2014 Air Cooled Single Screw Chiller/ Heat Pump Models: MCS050.1-380.2F MHS050.1-380.2F Cooling Capacity: 169kW-1370kW Heating Capacity: 179kW-1439kW Refrigerant: R22/R407C Engineered

More information

Introducing the TM /

Introducing the TM / Introducing the TM2500+ 8 / What s New? LM2500 PLUS gas turbine Up to 30% more power! Two-trailer design 75% reduction in footprint Improved interconnection design Faster installation and set-up 9 / 31%

More information

APPENDIX A. Mechanical Equipment Sheets: York Chiller Marley Cooling Towers Calmac IceBank Storage Tanks Low Temp Air Cooling Coils

APPENDIX A. Mechanical Equipment Sheets: York Chiller Marley Cooling Towers Calmac IceBank Storage Tanks Low Temp Air Cooling Coils APPENDIX A Mechanical Equipment Sheets: York Chiller Marley Cooling Towers Calmac IceBank Storage Tanks Low Temp Air Cooling Coils FORM 201.24-EG3 (1201) YCWS WATER COOLED LIQUID CHILLER HFC-407C 89 TONS

More information

Twin Screw Compressor Type HITACHI Water Cooled Water Chillers [H] SERIES

Twin Screw Compressor Type HITACHI Water Cooled Water Chillers [H] SERIES Twin Screw Compressor Type HITACHI Water Cooled Water Chillers [H] SERIES Nominal Cooling Capacity Range R22: 139.5 kw 1825 kw 119,970kcal/h 1,569,500kcal/h 39.7 RT 519.1 RT R407C: 130 kw 1755 kw 111,800kcal/h

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan Driving and Connecting Globally Fan Coil Unit : PHW-K Size : 510CMH~2720CMH Made in Taiwan Features Superior low-height design. Stainless steel drain pan for condensate and corrosion protection. Flexibe-reverse

More information

First Domestic High-Efficiency Centrifugal Chiller with Magnetic Bearings: The ETI-MB Series

First Domestic High-Efficiency Centrifugal Chiller with Magnetic Bearings: The ETI-MB Series 82 First Domestic High-Efficiency Centrifugal Chiller with Magnetic Bearings: The ETI-MB Series KENJI UEDA *1 YASUSHI HASEGAWA *2 NAOKI YAWATA *2 AKIMASA YOKOYAMA *2 YOSUKE MUKAI *3 The efficiency and

More information

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw TWA 212-1102 S/K/P Incorporating R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw The complete solution to all your cooling needs TWA 212-1102 S/K/P Index

More information

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low

More information

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS Air/water chillers and heat pumps LSE Outdoor packaged unit LSE 60-00 kw Multi-scroll solutions for reliability and high efficiency at partial loads Scroll compressor PLUS R-0A R-0A refrigerant Cooling

More information

Air cooled chillers With axial fans and power ratings from 238 to 1600 kw with two-screw compressor

Air cooled chillers With axial fans and power ratings from 238 to 1600 kw with two-screw compressor NS Air cooled chillers With axial fans and power ratings from 238 to 1600 kw with two-screw compressor R134a Aermec adhere to the EUROVENT Certification program up to 600 kw. The products concerned appear

More information

Product Catalog TSE Series Scroll Central Chillers

Product Catalog TSE Series Scroll Central Chillers Product Catalog TSE Series Scroll Central Chillers Contents Features...1 Available Options...3 Hot Gas Bypass Valve... 3 Rotary Non-Fused Disconnect Switch... 3 Integral Reservoir and Pumping System...

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

Calculation of external available Pressure. 1. Criterion flow velocity (Ref. 20 C) Do not design units in conditions acc. to white areas!

Calculation of external available Pressure. 1. Criterion flow velocity (Ref. 20 C) Do not design units in conditions acc. to white areas! Page 1 Standard Series Size: 3 Air flow volume Calculation of external available Pressure [m³/h] 3 4 5 55 6 65 7 75 8 9 1 11 12 1. Criterion flow velocity (Ref. 2 C) Do not design units in conditions acc.

More information

Module 4: Climate Control

Module 4: Climate Control ÂÂ ÂÂ Air-Conditioning Electronic Control Unit (ECU) Â Controlling Cabin Air Temperature Servo Motors Electric Servo Motors ÂÂ Air-Conditioning Electronic Control Unit (ECU) Automatic Climate Control Sensors

More information

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser The ZC 107 Zone Control System was designed to provide the perfect comfort control within the home. At the same time it was designed to make an airconditioning system work more efficiently and thereby

More information

CENTRIFUGAL CHILLER TECHNICAL DATA SHEET Job Name: Mt Healthy Junior Senior HS Date: 6/25/2009 Version: 06.12 Submitted By: Mary Wilking Unit Description: McQuay Model Number: WSC100MBJ72R/E4212-CE-3**/C3612-BLYY-2*****/R134-BAABM

More information

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw LOW NOx T The RL/M BLU burners series covers a firing range from 360 to 1023 kw, and it has been designed for use in hot or superheated water boilers, hot air or steam generators and diathermic oil boilers.

More information

technical catalogue tetris KW Chiller and heat pumps air/water

technical catalogue tetris KW Chiller and heat pumps air/water technical catalogue tetris 110 930 KW Chiller and heat pumps air/water > TETRIS Water chiller > TETRIS /HP Reversible heat pump > TETRIS /ST Water chiller with storage tank and pumps > TETRIS /DC Unit

More information

CHP SERIES FEATURES. High Pressure Control Three Phase Models. Low Ambient Fan Cycle Control Three Phase Models

CHP SERIES FEATURES. High Pressure Control Three Phase Models. Low Ambient Fan Cycle Control Three Phase Models CHP SERIES FEATURES HEAT PUMP CONDENSING UNIT 220V-1-50 380/420V-3-50 High Efficiency Scroll Compressors Proven Reliability in Harsh Environments Prepainted Galvanized Steel Triple Step Paint Process One

More information

Product Data. Features/Benefits. 30GUN,GUR Air-Cooled Reciprocating Liquid Chillers (HFC-134a) with ComfortLink Controls 50/60 Hz

Product Data. Features/Benefits. 30GUN,GUR Air-Cooled Reciprocating Liquid Chillers (HFC-134a) with ComfortLink Controls 50/60 Hz Product Data 30GUN,GUR Air-Cooled Reciprocating Liquid Chillers (HFC-134a) with ComfortLink Controls 50/60 Hz Nominal Capacities: 25 to 280 Tons 88 to 985 kw Features/Benefits ComfortLink control Your

More information

ENR Incorporating

ENR Incorporating ENR 002-480 Incorporating R410A Refrigerant Air cooled water chillers with scroll compressors and axial fans, 2.2-480kW ENR 002-100 models inc. self-cleaning coaxial evaporators ENR 130-480 models inc.

More information

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series 6. HUMIDIFIER SECTIONS Liquid Chiller nowlc And noalc Series C Member 1 Features and Benefits OMRAN cold generator reciprocating Liquid chiller are designed and built to provide reliable,efficient performance

More information

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C) Simple, reliable efficient heat pump! Equipped with µconnect controller HFC R410A CERTITA CERTIFIED * Cooling capacity: 5 to 16.5 kw Heating capacity: 6 to 19 kw *except 75HT OPTION HEAT PUMP HEATING (30/35

More information

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7 Calculation of external available Pressure Page 1 Size: 1 Air flow volume [m³/h] 4 6 8 1 12 14 16 18 2 24 28 32 36 1. Criterion flow velocity (Ref. 2 C) Do not design units in conditions acc. to white

More information

Bottle type configuration on counterflow design maximizes heat-exchanging efficiency, while minimizes acquisition cost as well as installation cost.

Bottle type configuration on counterflow design maximizes heat-exchanging efficiency, while minimizes acquisition cost as well as installation cost. KING UN INDUTRY MAIN BENEFIT Bottle type configuration on counterflow design maximizes heat-exchanging efficiency, while minimizes acquisition cost as well as installation cost. FEATURE FRP Casing & sin

More information

Product Catalog TSE Series Scroll Central Chillers

Product Catalog TSE Series Scroll Central Chillers Product Catalog TSE Series Scroll Central Chillers Contents Features...1 Hot Gas Bypass Valve... 2 Rotary Non-Fused Disconnect Switch... 2 Integral Reservoir and Pumping System... 3 Remote Condenser Coil

More information

Service Manual. Contents. Names of components. 3. Specifications Wiring Diagam Sequence Time Chart

Service Manual. Contents. Names of components. 3. Specifications Wiring Diagam Sequence Time Chart Service Manual Contents 1. Names of components 2 2. Safety Devices 3 3. Specifications 4 4. Wiring Diagam 4 5. Sequence Time Chart 5 6. 7. 8. Troubleshooting 6 Standard resistance & Voltage 13 Check &

More information

Unit Report For CH-1 30RB070 Project: UNF Soccer Stadium 04/21/2017

Unit Report For CH-1 30RB070 Project: UNF Soccer Stadium 04/21/2017 Unit Report For CH-1 30RB070 Unit Information Tag Name: CH-1 30RB070 Model Number: 30RB070 Condenser Type: Air Cooled Compressor Type: Scroll Nameplate Voltage: 460-3-60 V-Ph-Hz Quantity: 1 Manufacturing

More information

2. Discuss the effects of the following operating variables on detonation

2. Discuss the effects of the following operating variables on detonation Code No: RR220303 Set No. 1 II B.Tech II Semester Regular Examinations, Apr/May 2006 THERMAL ENGINEERING-I ( Common to Mechanical Engineering and Automobile Engineering) Time: 3 hours Max Marks: 80 Answer

More information

ËÕߪ Õ» ç åé. 50BY/BL Series. Single-Package Cooling Units 90, ,500 BTUH. World's No.1 Air Conditioning Expert

ËÕߪ Õ» ç åé. 50BY/BL Series. Single-Package Cooling Units 90, ,500 BTUH. World's No.1 Air Conditioning Expert ËÕߪ Õ» ç åé BY/BL Series Single-Package Cooling Units 90,000-895,0 BTUH World's No.1 Air Conditioning Expert www.carrier.co.th BY/BL Series Features Commercial or Industrial Applications Single- or Multiple-Unit

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

LAUDA Variocool. Numerous options, compact design, easy operation

LAUDA Variocool. Numerous options, compact design, easy operation LAUDA Variocool Circulation chillers for variable use in laboratory, mini-plant and production for temperatures from -20 up to 40 C (optional up to 80 C) Numerous options, compact design, easy operation

More information

PRICED BILL OF QUANTITIES Package : Air conditionning. Manhours (h) Unit (tariff) Discount Total Unit. Total. Material cost

PRICED BILL OF QUANTITIES Package : Air conditionning. Manhours (h) Unit (tariff) Discount Total Unit. Total. Material cost Spend study of price carries out by Margins ratios (rate on selling price) Mark up (coef. on cost price) - Overheads 15,00% Mark up (N1) 1,25 - Profits 2,00% - Mark up N 1 1,20 1 - Consulting firm fees

More information

Product Data. Features/Benefits. 30GTN,GTR Air-Cooled Reciprocating Liquid Chillers with ComfortLink controls 50/60 Hz

Product Data. Features/Benefits. 30GTN,GTR Air-Cooled Reciprocating Liquid Chillers with ComfortLink controls 50/60 Hz Product Data Air-Cooled Reciprocating Liquid Chillers with ComfortLink controls 50/60 Hz Nominal Capacities: 36 to 410 Tons 127 to 1445 Features/Benefits ComfortLink control Your link to a world of simple

More information

Benefits of an air preheater replacement. Benefits of an air preheater replacement unit in a large CDU furnace

Benefits of an air preheater replacement. Benefits of an air preheater replacement unit in a large CDU furnace Benefits of an air preheater replacement unit in a large CDU furnace Content 1) Existing situation 2) Design criteria 3) Replacement 4) Results Content 1) Existing situation 2) Design criteria 3) Replacement

More information

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

HYDROCIAT LW R134a. Water cooled chillers USE RANGE Screw compressors CIAT direct expansion shell and tubes evaporator equipment (High Power System) Cooling or heating Heat recovery ENVIRONMENTALLY HFC R134a PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling

More information

C32 ACERT Generator Set Electric Power

C32 ACERT Generator Set Electric Power Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Generator Set Specifications

More information

HWT 1402/9603. free cooling

HWT 1402/9603. free cooling irwater chillers for outdoor installation with free cooling Screw compressors, shell and tube heat exchangers and axial fans NSM Cooling capacity 306-2001kW HWT 14029603 free cooling HIGH EFFICIENCY LSO

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

CWP-CO / CWP-RC / CWP-HP 02 to 35

CWP-CO / CWP-RC / CWP-HP 02 to 35 Water Cooled Water Chillers Cooling Only, Condenserless and Heat Pump Versions - / - / - 02 to 35 8 to 136 9 to 164 Technical Brochure TM -N.4GB Date : March 2006 Supersedes : TM -N.3GB/05.04 Technical

More information

CHILLED WATER FAN-COIL UNITS

CHILLED WATER FAN-COIL UNITS 40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in

More information

Product Data. Features/Benefits

Product Data. Features/Benefits Product Data 30,,HW Reciprocating Liquid Chillers with COMFORTLINK Controls 50/60 Hz Nominal acities: 30HW 15 to 40 Tons (53 to 141 ) 30 40 to 60 Tons (141 to 210 ) 30 50 and 60 Tons (176 and 210 ) 30,S

More information

DF / DFB / DFC DOUBLE WIDTH DOUBLE INLET FORWARD CURVED FANS

DF / DFB / DFC DOUBLE WIDTH DOUBLE INLET FORWARD CURVED FANS Catalog 6131 DF / DFB / DFC DOUBLE WIDTH DOUBLE INLET FORWARD CURVED FANS FOR ORIGINAL EQUIPMENT MANUFACTURES SERIES 1600 1/98 APPLICATIONS AND AVAILABLE TYPES DF - DFB - DFC DOUBLE INLET FANS DOUBLE INLET

More information

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105 TECHNICAL CATALOGUE WPHA Cooling only WPHBA Heat pump Models 091, 121, 141, 171, 201, 251, 351, 401, 501, 701, 751, 1001, 1201 Cooling capacities from 2,4 kw to 41 kw Heating capacities from 2,8 kw to

More information

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual. Chiller SWS/SWR 1602 to 4802 Water Cooled Chillers Only and Condenserless Versions Engineering Data Manual 272 to 1118 kw Specifications General The SWS water cooled screw chillers are equipped with high

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h Engineering Data Manual New : available with EC motor VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 800 to 4650 m 3 /h General Characteristics Presentation On model VH 07, coils have 4

More information

TECHNICAL INFORMATION F25 AS LT3 12/2011 / B 1

TECHNICAL INFORMATION F25 AS LT3 12/2011 / B 1 F25 AS LT3 1 WORKING MACHINE WITH SOLVENT HYDROCARBON MACHINE CAPACITY 25 Kg 55 60 Lbs BASKET Diameter 1000 mm 39.4 inches Depth 640 mm 25.2 inches Volume 500 Lt 14.1 cu.ft Wash speed 20 50 rpm Extract

More information

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP Space Heaters This Parts Listing has been compiled for your benefit. You can be assured your space heater was constructed and designed with quality and performance

More information

Providing a constant temperature control and high cooling efficiency.

Providing a constant temperature control and high cooling efficiency. Recirculating Coolers (General) Providing a constant temperature control and high cooling efficiency. Performance Temperature range from 3 to 40. High cooling capacity up to 7.1kW at 20. Powerful circulating

More information

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls SPRING CHECK LIST ABSORPTION CHILLERS Check starter and control panel. Leak test. Check hand valve diaphragms and replace as required. Check operation of purge unit. Change oil in the purge pump. Lubricate

More information

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers Engineering Data Manual Water Cooled Water Chillers Cooling Only Version () Condenserless Version () Heat Pump Version () Models 02 to 35 8 to 136 9 to 164 N IRWELL GROUP MPNY Specifications General The

More information

TECHNICAL INFORMATION HXL 8015 S 11/2011 / 730-C 1

TECHNICAL INFORMATION HXL 8015 S 11/2011 / 730-C 1 1 WORKING MACHINE WITH SOLVENT HYDROCARBON MACHINE CAPACITY 15 Kg 35 Lbs BASKET Diameter 800 mm 31.5 inches Depth 560 mm 22 inches Volume 285 Lt 10.1 cu.ft Wash speed 20 55 rpm Extract speed 300 500 rpm

More information

Installation- and maintenance instruction B45A2.2

Installation- and maintenance instruction B45A2.2 Installation- and maintenance instruction B45A2.2 160 012 85 DESCRIPTION Components 1. Flame cone 2. Fan housing 3. Fan wheel 4. Damper motor 5. Motor 6. Pump 7. Shrouded disc 8. Nozzle 9. Ignition transformer

More information

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 1 and CTM 2 Liquid Ejector

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 1 and CTM 2 Liquid Ejector Data sheet Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 1 and CTM 2 Liquid Ejector Liquid Ejector is a part of the CO2 Adaptive Liquid Management (CALM), ' solution to handle liquid in

More information

SOAPP-CT.25 WorkStation 11/1/00. Equipment List Project: Sample Outputs Conceptual Design: Cogen, 1 x 27 MW, NG, Quarterly

SOAPP-CT.25 WorkStation 11/1/00. Equipment List Project: Sample Outputs Conceptual Design: Cogen, 1 x 27 MW, NG, Quarterly GENERAL PROJECT DATA Ambient Conditions Maximum Site Ambient Dry Bulb Temp 85.00 F Maximum Site Ambient Wet Bulb Temp 74.00 F Minimum Site Ambient Dry Bulb Temp -20.00 F Site Average Annual Rainfall 31.00

More information

Semi Hermetic. Refrigeration Technologies RECIPROCATING COMPRESSORS. R134a, R404A, R507A, R407C, R22, R410A* R508b

Semi Hermetic. Refrigeration Technologies RECIPROCATING COMPRESSORS. R134a, R404A, R507A, R407C, R22, R410A* R508b A n I S O 9 0 0 : 0 0 0 O r g a n i z a t i o n Refrigeration Technologies Semi Hermetic RECIROCATING COMRESSORS R34a, R4A, R7A, R7C, R, R40A* R8b Approved by European standards ENVIRONMENT FRIENDLY LESS

More information

POWERBLOCK GENERATION SYSTEMS

POWERBLOCK GENERATION SYSTEMS Product Specifications POWERBLOCK GENERATION SYSTEMS EPA Tier 2/Tier 4 Final Certified PowerBlock Systems Ratings: 600 kw/750 kva to 3125 kw/3910 kva 208V to 480V at 60 Hz 2 Patented Design The PowerBlock

More information

Emerging Oil Free Technologies. Ray Good Global Director of Application Engineering Danfoss Turbocor Compressors, Inc.

Emerging Oil Free Technologies. Ray Good Global Director of Application Engineering Danfoss Turbocor Compressors, Inc. Emerging Oil Free Technologies Ray Good Global Director of Application Engineering Danfoss Turbocor Compressors, Inc. rgood@danfoss.com 1 Agenda Chiller Overview Benefits of Oil Free Oil Free Compressors

More information

Unit Report For CH-1 Replacement Project: Marlboro County High School Chiller Replacement 10/22/2018

Unit Report For CH-1 Replacement Project: Marlboro County High School Chiller Replacement 10/22/2018 Unit Report For CH-1 Replacement Unit Information Tag Name: CH-1 Replacement Model Number: 30RAP050 Condenser Type: Air Cooled Compressor Type: Scroll Nameplate Voltage: 460-3-60 V-Ph-Hz Quantity: 1 Manufacturing

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information

REX/REX F/REX K/REX K F REX DUAL/REX DUAL F

REX/REX F/REX K/REX K F REX DUAL/REX DUAL F TECHNICAL MANUAL REX/REX F/REX K/REX K F REX DUAL/REX DUAL F PRESSURISED STEEL BOILERS INDEX 1 GENERAL WARNINGS... 4 2 TECHNICAL SPECIFICATIONS... 5 2.1 REX/REX K/REX F/REX K F 7-130 BOILER... 5 2.2 REX/REX

More information

Installation- and maintenance instruction BENTOFLEX ST 108 PL

Installation- and maintenance instruction BENTOFLEX ST 108 PL Installation- and maintenance instruction BENTOFLEX ST 108 PL 1 171 625 30 03-01 178 001 13 DESCRIPTION COMPONENTS 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION 1 WORKING MACHINE WITH SOLVENT: HYDROCARBON MACHINE CAPACITY Lbs 60 BASKET Diameter Depth Volume Wash speed Extract speed Door opening inches 39.4 inches 25.2 gal 132 rpm 12 50 rpm 300 540 inches 20 SOLVENT

More information

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 330 to 500 kw Heating capacity: 340 to 500 kw Cooling

More information

Four Way Reversing Valve

Four Way Reversing Valve Four Way Reversing Valve RANCO series four-way reversal valve are applicable for hot pump systems such as central, unit and room air conditioners. The switch between cooling mode to heating mode can be

More information

TEAMTEC INCINERATORS Market leaders since More than units sold worldwide

TEAMTEC INCINERATORS Market leaders since More than units sold worldwide TEAMTEC INCINERATORS Market leaders since 1972 - More than 11 000 units sold worldwide OG120C. Capacity: 190.000 kcal/h (220 kw). TEAMTEC Incinerator model OG120C The smallest incinerator in our range.

More information

Air-cooled Chiller R-22

Air-cooled Chiller R-22 Air-cooled Scroll type:5rt ~ 60RT Screw type:50rt ~ 240RT 50 Hz Technology-Rooted Service-Oriented MADE IN TAIWAN The information provided in this catalog may vary as a result of further development of

More information

Y-Flow TCHEY-THHEY

Y-Flow TCHEY-THHEY Y-Flow TCHEY-THHEY 245-4450 Cooling capacity: 41.2 448.8 kw - Heating capacity: 50.23 515.49 kw Applications with well water, water mains or geothermal probes Integrated MASTER/SLAVE control HT65 version

More information

Installation- and maintenance instruction B80-2/3

Installation- and maintenance instruction B80-2/3 Installation- and maintenance instruction B80-2/3 1 171 625 22 05-01 178 002 64 DESCRIPTION COMPONENTS 1. Flame cone 2. Shrouded disc 3. Nozzle 4. Nozzle assembly 5. Ignition electrodes 6. Ignition cable

More information

HYDROVANE ROTARY VANE COMPRESSOR WITH REGULATED SPEED - THE 'RS' RANGE (7kW - 75kW)

HYDROVANE ROTARY VANE COMPRESSOR WITH REGULATED SPEED - THE 'RS' RANGE (7kW - 75kW) HYDROVANE ROTARY VANE COMPRESSOR WITH REGULATED SPEED - THE 'RS' RANGE (7kW - 75kW) Performance and Technical Data. Please refer to the final 2 pages of this document. Hydrovane are pleased to announce

More information

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION 03/2004 648-A 1 WORKING MACHINE WITH SOLVENT: PERCLORETHILENE MACHINE CAPACITY (RATIO 1:20) Lbs 55 60 BASKET Diameter Depth Volume Wash speed without Inverter Extract speed without Inverter Wash speed

More information

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC Product Introduction INTRODUCTION Johnson Controls YORK YECFC fan coil units are high efficiency, low profile,

More information

Installation- and maintenance instruction BENTOFLEX ST120KAV

Installation- and maintenance instruction BENTOFLEX ST120KAV Installation- and maintenance instruction BENTOFLEX ST120KAV 1 171 625 61 05-01 178 001 16 DESCRIPTION COMPONENTS 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly

More information

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and

More information

Start-up Instructions

Start-up Instructions RadMax Burners Page 400-S- Start-up Instructions Read complete instructions before proceeding and familiarize yourself with all the system s equipment and components. Verify that all equipment has been

More information

Total comfort control

Total comfort control Total comfort control YORK ACTIVE CHILLED BEAM WITH PERFORATED RETURN DIFFUSER Table of contents Concept & Technology Air Distribution & Facade Orientation Product Features Dimensions Performance Data

More information

CATERPILLAR 3516B DP2 System

CATERPILLAR 3516B DP2 System CATERPILLAR 3516B DP2 System CONTENTS System Overview 3 Offshore Rig or Ship DP2 Package 3 Main Generator Diesel Skid 3 Main Generator Diesel Engines 3 Instrument, Alarms and Automatic Start/Stop System

More information

Powered by Dongfeng Cummins 4B Series Engine. Genset Prime Power Range: 27kw-80kw. Basic Characteristics of Diesel Generator Set

Powered by Dongfeng Cummins 4B Series Engine. Genset Prime Power Range: 27kw-80kw. Basic Characteristics of Diesel Generator Set Powered by Dongfeng Cummins 4B Series Genset Prime Power Range: 27kw-80kw Basic Characteristics of Diesel Generator Set All series powered by Dongfeng Cummins engine, modern technique, dependable performance,high

More information

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS 1 to 40 Nominal Tons Rev-01 TABLE OF CONTENTS Page: Description 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Product Nomenclature Air Cooled Chiller

More information

Address: VTS Clima L.L.C.

Address: VTS Clima L.L.C. Address: VTS Clima L.L.C. Business Bay, Churchill Tower, Office 2409, P.O.Box#76849 Dubai, UAE phone: +971 (4) 443 91 20 fax: +971 (4) 443 96 20 e-mail: dubai@vtsgroup.com www.uae.vtsgroup.com Index VTS

More information

PowerWave 33, kw

PowerWave 33, kw PowerWave 33, 60 500 kw Unmatched power performance Standalone three-phase UPS system continuous power protection availability Newave A member of ABB Group PowerWave 33 the powerhouse Newave has always

More information

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

CLOSE CONTROL UNITS WITH CHILLED WATER COIL CLOSE CONTROL UNITS WITH CHILLED WATER COIL COOLING CAPACITY FROM 5 TO 154 kw 230 D 56 The range of chilled water close control units, series, is particularly indicated for use in technological centres,

More information

Installation- and maintenance instruction BENTOFLEX ST133KA/K

Installation- and maintenance instruction BENTOFLEX ST133KA/K Installation- and maintenance instruction BENTOFLEX ST133KA/K 178 007 17 DESCRIPTION Components 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly 6. Nozzle 7.

More information

Legat-65. Voltage Stabilizer Technical Certificate. NOVATEK-ELECTRO LTD Research-and-Manufacture Company

Legat-65. Voltage Stabilizer Technical Certificate.   NOVATEK-ELECTRO LTD Research-and-Manufacture Company NOVATEK-ELECTRO LTD Research-and-Manufacture Company Legat-65 Voltage Stabilizer Technical Certificate www.novatek-electro.com 1. Application Legat-65 single-phase voltage stabilizer, hereinafter referred

More information

High Static Pressure Duct Fan Coil Unit

High Static Pressure Duct Fan Coil Unit MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4

More information

BC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat)

BC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat) BCAHSG-2 3-Jun BC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat) 5 YEAR WARRANTY see warranty form for details Contents: Page Number Product Features 2

More information

LAUDA Variocool. Numerous options, compact design, easy operation

LAUDA Variocool. Numerous options, compact design, easy operation LAUDA Variocool Circulation chillers for variable use in laboratory, mini-plant and production for temperatures from -20 up to 40 C (optional up to 80 C) Numerous options, compact design, easy operation

More information

(UK) Date : January 2014

(UK)   Date : January 2014 Sentinel Door Curtain - Model 270 Installation, Operation & Maintenance Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD Tel. 023 9247 7700 Fax. 023 9245 3601 (Global) www.dunham-bush.com Document

More information

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING 199 RE ER RS SO AIR COOLED HEAT PUMP LIQUID CHILLERS 19,1 261,0 kw COOLING 23,7 333,0 kw HEATING R410A PLATE RCGROUP SpA 19632013 fiftycoolyears 200 VERSIONS: (R410A) Cooling capacity 19,2 261,0 kw Heating

More information

TECHNICAL INFORMATION HXL8018S-K 11/2012 / 733-B 1

TECHNICAL INFORMATION HXL8018S-K 11/2012 / 733-B 1 HXL8018S-K 1 WORKING MACHINE WITH SOLVENT HYDROCARBON / GREEN EARTH / SOLVON K4 MACHINE CAPACITY 18 Kg 40 Lbs BASKET Diameter 900 mm 35.4 inches Depth 535 mm 21 inches Volume 340 Lt 12 cu.ft Wash speed

More information

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts DIESEL GENERATOR SET PRIME 808 ekw 1010 kva Caterpillar is leading the power generation market place with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

Wärtsilä Auxpac PRODUCT GUIDE

Wärtsilä Auxpac PRODUCT GUIDE Wärtsilä Auxpac PRODUCT GUIDE Copyright by WÄRTSILÄ FINLAND OY All rights reserved. No part of this booklet may be reproduced or copied in any form or by any means (electronic, mechanical, graphic, photocopying,

More information

Butterfly valves PN 16

Butterfly valves PN 16 s 4 119 ACVATIX TM Butterfly valves PN 16 VKF42.. Gray cast iron or nodular cast iron valve body DN 50...600 k vs 65...37,000 m 3 /h For fitting with PN 16 counter-flanges to ISO 7005 Tight-closing in

More information

DAEIL AQUA CO., LTD.

DAEIL AQUA CO., LTD. MAIN CONTRACTOR: MANUFACTURER: Model No. DI-LXP-200RT 1 CELLS Relative Humidity (%) 80 Cooling Capacity (kal/hr) 780000 Water Flow Rate (m 3 /hr) 156 (2600lpm) Number of Cell 1 Total Fan Horse Power (hp)

More information