1 ABS submersible mixer RW ABS submersible recirculation pumps RCP RCP SB-KA RW GB Installation and Operating Instructions
2 2 Installation and Operating Instructions Installation and Operating Instructions RW 300 RW 400 RW 650 RW 900 RW 400 LW RW 550 DM RW 650 LW RCP 250 RCP 400 RCP 500 RCP 800 SB 1236 KA SB 1237 KA
3 Installation and Operating Instructions 3 1 General Safety Transport and storage Product description RW 300/400/ RW 900/SB-KA RCP 400/ RCP Installation... 23
4 4 Installation and Operating Instructions Brackets RW/SB-KA Commisioning Maintenance
5 Installation and Operating Instructions 5
6 6 Installation and Operating Instructions 1 General 1.1 Introduction These Installation and Operating Instructions Safety Hints - m c g ATTENTION Appears at safety hints, the non-observance of which could damage the unit or affect its functioning. NOTE Used for important pieces of information. 1.2 Correct usage of the products - - of the installation and operating instructions and the safety hints 1.3 Application restrictions of RW/RCP/SB-KA Limitations: ATTENTION If cable length is less than 20 m/65 ft the max. immersion depth reduces accordingly. In special cases an immersion depth greater than 20 m/65 ft is possible. In order to do this you need the written approval from the manufacturer ABS.
7 g g For the operation of units as explosion-proof execution the following applies: Installation and Operating Instructions 7 ATTENTION RW/RCP with Ex d IIB T4 approval are not equipped with a DI in the oil chamber. ATTENTION RW 400/650 and RCP 400/500 with FM approval (NEC 500) can be equipped (as an option) with a special DI in the oil chamber. Due to the design this is not possible in RW 900 and RCP 800. For the operation of ex-rw/rcp applies: - For the operation of EX-RW/RCP with frequency inverter applies: 1.4 Application areas Application areas RW Application areas RCP -
8 8 Installation and Operating Instructions Application areas SB-KA - Hydraulics Motor AAA BB C D U VVV / W-XY.Z Ex EC; CR Material used Ex-version Gearbox ratio (only RW 900, RCP 800 and SB-KA) Motor size Number of poles in motor Motor power (P 2 [kw] x 10) Motor designation (e.g. A) Identity number Propeller type* Discharge size DN [cm] for RCP PropellerØ [cm] for RW/SB-KA Series 1.6 Technical data merged unit.
9 Installation and Operating Instructions Technical data RW 50 Hz Propeller Motor (50 Hz/400 V) Installation Mixer type Propeller diameter Speed Motor type Rated power input P 1 Rated power output P 2 Starting: Direct Starting: Star/Delta Rated current at 400 V Starting current at 400 V Cable type** Temperature monitoring Seal monitoring Ex d IIB T4 Total weight Total weight RW A 15/ RW A 15/ RW A 15/ RW A 28/ RW A 28/ RW A 28/ RW A 30/ RW A 30/ RW A 30/ RW A 30/ RW A 40/ RW A 40/ RW A 40/ RW A 50/ RW A 50/ RW A 50/ RW A 50/ RW A 50/ RW A 75/ RW A 75/ RW A 100/ RW A 110/ RW A 110/ RW A 110/ RW A 150/ RW A 150/ RW A 220/ RW A 220/ P 1 2 Other voltages available on request.
10 10 Installation and Operating Instructions Technical data RW 60 Hz Propeller Motor (60 Hz/460 V) Installation Mixer type Propeller diameter Speed Motor type Rated power input P 1 Rated power output P 2 Starting: Direct Starting: Star/Delta Rated current at 460 V Starting current at 460 V Cable type** Temperature monitoring Seal monitoring FM (NEC 500) Total weight Total weight RW A 17/ RW A 17/ RW A 32/ RW A 32/ RW A 35/ RW A 35/ RW A 35/ RW A 46/ RW A 46/ RW A 60/ RW A 60/ RW A 90/ RW A 90/ RW A 90/ RW A 120/ RW A 120/ RW A 130/ RW A 130/ RW A 130/ RW A 170/ RW A 170/ RW A 250/ RW A 250/ P 1 2
11 Installation and Operating Instructions Technical data RW- special executions Mixer type Propeller diameter Speed Motor type Rated power input P 1 Rated power output P 2 Starting: Direct Starting: Star/Delta Rated current Starting current Cable type** Temperature monitoring Seal monitoring Ex d IIB T4 Frequency Total weight RW 4033 LW A 40/ RW 6532 LW A 75/ RW 6533 LW A 100/ RW 5531 DM A 100/ RW 5531 DM A 120/ RW 5531 DM A 120/ P Technical data RCP 50 Hz Propeller Motor (50 Hz/400 V) RCP hydraulics type Propeller diameter Propeller speed H max Q max Motor type Rated input power P 1 Rated motor power P 2 Starting: Direct Starting: Star/Delta Rated current at 400 V Starting current at 400 V Cable type** Temperature monitoring Seal monitoring Ex d IIB T4 Total weight RCP A 15/ RCP A 28/ RCP A 28/ RCP A 40/ RCP A 40/ RCP A 40/ RCP A 40/ RCP A 40/ RCP A 40/ RCP A 50/ RCP A 75/ RCP A 75/ RCP A 75/ RCP A 100/ RCP A 100/ RCP A 150/ RCP A 220/ RCP A 220/ RCP A 220/ P 1 2
12 12 Installation and Operating Instructions Technical data RCP 60 Hz Propeller Motor (60 Hz/460 V) RCP hydraulics type Propeller diameter Propeller speed H max Q max Motor type Rated input power P 1 Rated motor power P 2 Starting: Direct Starting: Star/Delta Rated current at 460 V Starting current at 460 V Cable type** Temperature monitoring Seal monitoring FM (NEC 500) Total weight RCP A 17/ RCP A 32/ RCP A 32/ RCP A 46/ RCP A 46/ RCP A 46/ RCP A 46/ RCP A 90/ RCP A 120/ RCP A 120/ RCP A 120/ RCP A 130/ RCP A 250/ RCP A 250/ RCP A 250/ P Technical data SB-KA Propeller Motor Weight Flow booster type Propellerdurchdiameter Speed Motor type Rated input power P 1 Rated motor power P 2 Starting: Direct Starting: Star/ Delta Rated current at 400 V / 460 V Starting current 400 V / 460 V Cable type** Temperature monitoring Seal monitoring EEx dii BT4 Total weight SB 1236 KA A 30/ SB 1237 KA A 40/ SB 1236 KA A 35/ SB 1237 KA A 46/ P 1 2 NOTE Other voltages available on request.
13 Installation and Operating Instructions Dimensions and weights NOTE The weights of the units can be obtained from the nameplate of the unit or from the Dimensions RW Dimension RW 300 A15/28 A17/32 RW 400 A30/40 A35/46 RW 650 A50 A60 RW 650 A75 A90 RW 650 A100 A120 RW 900 A110/150 A130/170 RW 900 A220 A250 D 1 ø 300 ø 400 ø 650 ø 650 ø 650 ø 900 ø 900 D 2 ø 462 ø 560 ø 810 ø 810 ø 810 ø 1150 ø ø 158 ø ø ø ø ø ø h L L L L l l l
14 14 Installation and Operating Instructions Dimensions RCP 210,5 125, DN 250 Ø 52 Ø 267 X , min. 400 DN 400 min. 800 X 683
15 Installation and Operating Instructions DN500 min. 600 min X 865 (A50/12) 1005 (A75/12, A90/12, A100/12, A120/12) min. 700 DN 800 min X 1174 (A130/4, A150/4) 1274 (A220/4, A250/4)
16 16 Installation and Operating Instructions Dimensions SB-KA D C A C = 15 A B D SB 1236 KA SB 1237 KA D B C = 22 A B D SB 1236 KA SB 1237 KA C = 30 A B D SB 1236 KA SB 1237 KA Nameplate Figure File no Use with approved motor control that matches motor input in full load amperes. To reduce the risk of injury or electrical shock, disconnect the power be- fore raising or lowering and servicing this device Utiliser un Demarreur approuve covenant au courant a pleine charge du moteur This plate was supplied originally with certified pump FM APPROVED EXPLOSIONPROOF G k Ex d B T4 Do not open while energized Nicht unter Spannung öffnen Legend
17 Installation and Operating Instructions 17 NOTE In all communication please state type of the unit, item and serial number. 2 Safety Safety Hints 3 Transport and storage 3.1 Transport c m. - - m m m m 3.2 Transport securing devices Motor connection cable moisture protection ATTENTION These protective covers should only be removed immediately prior to connecting the pumps electrically. - ATTENTION NOTE These protective covers only provide protection against water spray or similar and are not a water tight seal. The ends of the cables should not be immersed in water, otherwise moisture could enter the connection chamber of the motor. If there is a possibility of water ingress then the cables should be secured so that the
18 18 Installation and Operating Instructions ATTENTION Take care not to damage the cable or its insulation when doing this! 3.3 Storage of the units sunlight, high humidity, aggressive dust emissions, mechanical damage, frost etc. The ABS original packaging with the relevant transport securing devices (where used) ensures optimum protection of the unit. If the units are exposed to tempera- tem, or other spaces. In the case of heavy frosts, the units and cable should not be moved if possible. When storing under extreme conditions, e.g. in tropical or desert conditions suitable additional protective steps should be taken. We would be glad to advise you further. NOTE 4 Product description 4.1 General description ABS units do not generally require any particular maintenance during storage. After long storage periods (after approx. one year), the transportation locking device on the motor shaft (not with all versions) should be disassembled. By rotating the shaft several times by hand, new lubricating oil or, depending on the version, a small amount of coolant (which also serves to cool or lubricate the mechanical seals) is applied to the sealing surfaces, thus ensuring perfect operation of the mechanical seals. The bearings supporting the motor shaft are maintenance-free. Motor Motor monitoring - Seal monitoring Operation with frequency inverters suitably selected Observe the EMC-Directive and the installation and operating instructions of the inverter manufacturer!
19 Installation and Operating Instructions Structural design RW/SB-KA RW 300/400/ RW 900/SB-KA
20 20 Installation and Operating Instructions Legend 1 Bracket 5 Stator 10 Propeller 13 Gear 4.3 Rinsing system for mechanical seal (Option) Z Z
21 Y Installation and Operating Instructions Structural design RCP RCP 400/ RCP
22 22 Installation and Operating Instructions Legend 6 Stator 9 Propeller 13 Gear 4.5 Operation with frequency inverters
23 Installation and Operating Instructions 23 U N [V] critical area non critical area 5 Installation m L[m] L = total length (from frequency inverter to motor) 5.1 Installation RW/SB-KA c c NOTE. We recommend that ABS installation accessories be used for the installation of the 5.2 Propeller assembly (only for RW 900 and SB-KA) position of the securing washers) and that the prescribed tightening torque is used!
24 24 Installation and Operating Instructions Legend 6 Propeller 5.3 Tightening torque Outer side of the 2 securing washers Inner side of the 2 securing washers Tightening torque for ABS stainless steel screws A4-70: Thread M6 M8 M10 M12 M16 M20 M24
25 Installation and Operating Instructions Installation examples RW/SB-KA Installation example with existing accessories Legend
26 26 Installation and Operating Instructions Legend
27 Installation and Operating Instructions Legend 8 9
28 28 Installation and Operating Instructions Installationsbeispiel SB-KA Fixed installation with vibration damper Vibration damper listing Mixer Part no. RW RW RW 650 RW 900/SB-KA RW 400/650 RW 900/SB-KA
29 Installation and Operating Instructions Brackets RW/SB-KA open closed Fitting of the open bracket with vertical swivelling (option) (2x) 9 (2x) 5 (2x) 4 (2x) 10 (2x) 2 (2x) 13 (2x) 10 (2x) 1 7 (2x) VKT (2x) 2 8 (2x) 9 (2x) 5 (2x) 4 (2x) 10 (2x) 10 (2x) 9 (2x) 10 (2x) 9 (2x) 6 (2x) 2 8 (2x) 5 (2x) 9 (2x) 4 (2x) 3 (2x) 11 (2x) 3 (2x) 1 VKT (2x) 10 (2x) 9 (2x) 10 (2x) 4 (2x) 9 (2x) 8 (2x) 5 (2x)
30 30 Installation and Operating Instructions Legend Fitting of the closed bracket with vertical swivelling (option) 2 (2x) (2x) 5 (2x) 9 (2x) 1 VKT (2x) 5 (2x) 3 (2x) 4 (2x) 9 (2x) 8 (2x) 6 (2x) (2x) 10 (2x) 11 (2x) 3 (2x) 1 VKT (2x) 9 (2x) Legend 6 Strap
31 Installation and Operating Instructions Guide tube lengths (square tube) RW/SB-KA - 3 Mixer/ Flow booster Maximum guide tube length (L) for an installation with square guide tube with push in type with separate guide tube with additional lifting unit lifting unit L L L RW 300 RW 400 RW 650
32 32 Installation and Operating Instructions 5.7 Installation RCP Installation example with ABS lifting unit
33 Installation and Operating Instructions Guide tube installation m
34 34 Installation and Operating Instructions Securing and positioning of the motor connection cables of the RCP m NOTE The cable holders described here are not supplied as part of the standard execution of the RCP c c.
35 Installation and Operating Instructions Lowering of the RCP along the guide tube m ATTENTION The power cable should be connected to the wire rope or chain in such a manner that it cannot become entangled in the propeller and that it is not subjected to any tension
36 36 Installation and Operating Instructions 5.8 Electrical connection m with regard to cross-sectional area and maximum voltage drop. The voltage stated on the nameplate of the pump must correspond to that of the mains c - on the nameplate. If you want to use other starting methods please consult the manufacturer. In the case a control panel is not supplied as standard the following applies: The unit must only be operated with a motor protection switch with overload relay and thermal sensors connected.
37 Installation and Operating Instructions Standard connection diagrams. mains voltage V at 50 Hz/460 V at 60 Hz U2 V2 U1 V1 PE U1 V Hz 60 Hz A 15/6 A 17/6 A 28/6 A 32/6 A 30/8 A 35/8 W2 M3 ~ W1 W1 F0 F1 DI U2 V2 W2 M3 ~ U1 V1 W1 PE U1 V1 W1 W2 U Hz 60 Hz A 40/8 A 46/8 A 50/12 A 60/12 A 75/12 A 90/12 A 110/4 A 120/12 A 130/4 A 170/4 V2 F0 F1 DI U2 V2 W2 M3 ~ U1 V1 W1 Cable 1 Di Di PE U1 V1 W Hz 60 Hz A 100/12 A 250/4 A 150/4 A 220/4 PE W2 U2 V2 F0 F1 Cable 2
38 38 Installation and Operating Instructions Lead designations Direct starting in star L1 L2 L W1 1 U1 4 U2 6 5 W2 V2 3 2 W1 V Direct starting in delta L1 L2 L W2 1 U W1 3 5 V2 U2 4 V12 c turer (See following table)....ac/...dc V ~/ V= AC 250 V AC cos = A AC cos = A I N 5.0 A Soft starter (Option) ATTENTION The units must be connected DOL when used with soft starters Legend PE U2 U1 U1 V2 V1 V1 W2 M3 ~ W1 W1 2 3 F0 F1 DI RW/RCP/SB-KA
39 Installation and Operating Instructions Testing and adjustment of soft starter: Test: Setting: Set to the lowest possible starting torqu Set to the longest possible starting time Checking direction of rotation m
40 40 Installation and Operating Instructions c m Start reaction NOTE If a number of units are connected to a single control panel then each unit must be individually checked. ATTENTION The mains supply in the control panel must have a clockwise sense of rotation. If the units are connected in accordance with the wiring diagram and the lead designations the direction of rotation will be correct Changing direction of rotation m c NOTE The direction of rotation measuring device monitors the direction of rotation of the mains supply or that of an emergency generator.
41 Installation and Operating Instructions Connection of the seal monitoring unit to the control panel ATTENTION If the DI-seal monitoring is activated the unit must be immediately taken out of service. Please contact your ABS service centre. MAINS MAINS 3 (DI) PE M2+ 3 (DI) PE M2+ M1- M Electrode X1 X2 Bulb 24V 2-5 W Electrode / MAINS 3 (DI) PE M2+ M1- Pump 2 Pump Electrode ATTENTION Maximum relay contact loading: 2 Ampere.
42 42 Installation and Operating Instructions 6 Commisioning m 6.1 Types of operation min. H min. 0,5 B ATTENTION ATTENTION The illustration is only an example. For the correct installation please contact ABS. Operation within the directly aerated area is not allowed! not vibrate heavily when in operation.
43 Installation and Operating Instructions 43 7 Maintenance m 7.1 General maintenance hints c NOTE g The maintenance hints given here are not designed for do-it-yourself repairs as special technical knowledge is required. - - ATTENTION The lifting tools like chains and shackles should be visually checked in regular inter- if required! NOTE ATTENTION The ABS warranty conditions are only valid provided that any repair work has been carried out in ABS approved workshops and where original ABS spare parts have been used. Regular checks are highly recommended and other checks are prescribed regula-
44 44 Installation and Operating Instructions 7.2 Maintenance RW/RCP and SB-KA m Faults - Possible causes: 7.3 Inspection and maintenance intervals for RW/RCP and SB-KA m PERIOD OF TIME: Regulation: once a month - -
45 Installation and Operating Instructions 45 PERIOD OF TIME: PERIOD OF TIME: PERIOD OF TIME: PERIOD OF TIME: Recommendation: once a month Regulation: every 3 months - Recommendation: every 6 months Recommendation: once a year
46 46 Installation and Operating Instructions Recurringchecks(at leastonceayear) Date Remarks Operating hours Signature Repaired on/by
47 Installation and Operating Instructions 47 Recurringchecks(at leastonceayear) Date Remarks Operating hours Signature Repaired on/by
48
Flow booster type ABS SB 900 to 2500
Flow booster type ABS SB 900 to 2500 6005583 EN 08.2018 en EN 0580-I Installation and operating instructions Translation from original instruction www.sulzer.com Installation and operating instructions
More informationIP 900 W/KS & IP 900 D/KS
B W/KS & D/KS Installation and operating instructions We reserve the right to make modifications in the interest of technical development (4) 15975178 GB 04/05 1 pplication reas The submersible waste-water
More informationABS submersible sewage pump AFP
BS submersible sewage pump FP - Robust, reliable submersible pumps from. to kw for pumping wastewater and sewage from buildings and sites in private, commercial, industrial and municipal areas in accordance
More informationABS lifting station Synconta
15975187GB (03/2006) 106800 GB Installation and Operating Instructions www.absgroup.com Installation and Operating Instructions 601 801 901 901L 902 902L Contents 1 General... 3 1.1 Application areas...
More informationSubmersible Sewage Pumps Type ABS XFP
Submersible Sewage Pumps Type ABS XFP Main Applications Submersible sewage pump type ABS XFP is designed for municipal and industrial wastewater equipped with Premium Efficiency (IE3 level) motor for:
More informationNo: En Revision Parts List. Matador O-RING KIT BASIC REPAIR KIT B_8106_180_expl_view
No: 897386 En Revision 9.0 0 0 Parts List Matador 806.80 www.grindex.com O-RING KIT 80 BASIC REPAIR KIT 90 90 0086B_806_80_expl_view Parts List Matador 806.80 Overview Table of Contents This publication
More informationSubmersible Mixer. Amamix. 60 Hz. Type Series Booklet
Amamix 60 Hz Type Series Booklet egal information/copyright Type Series Booklet Amamix All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed
More informationSubmersible Sewage Pumps Type ABS XFP
Submersible Sewage Pumps Type ABS XFP Main Applications Submersible sewage pump type ABS XFP is designed for municipal and industrial wastewater equipped with Premium Efficiency (IE3 level) motor for:
More informationMOUNTING & MAINTENANCE INSTRUCTIONS FOR
9 Pages / Page 1 MOUNTING & MAINTENANCE INSTRUCTIONS FOR THREEPHASE INDUCTION MOTORS - TYPES DM1 / DMA1 / DMA2 TABLE OF CONTENTS page 1 General information 2 2 Delivery 2 3 Mounting 2 4 Coupling 2 4.1.
More informationTECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION Star/delta starter Description: The electromagnetic starters LT 3 Dxx series are devices designed for remote control, direct control and protection of induction motors coiled and
More informationCooling Systems FLKS - 3S/1.0/W... FLKS - 3L/1.0/W DESCRIPTION
Cooling Systems FLKS - S/1.0/W... FLKS - L/1.0/W... 1. DESCRIPTION 1.1. APPLICATIONS Cooling circuits: Cooling of AC main drives Cooling of motor spindles on machining centres Cooling of transmission and
More informationCooling shrouds. Applications. Cooling shroud for submersible borehole pumps UPA and S100B 50 Hz. Operating data. Design.
Type series booklet 3440.52/2-10 G2 Applications A cooling shroud will typically reduce the temperature of a submersible borehole pump motor by 10 C. We recommend to use a cooling shroud for the following
More informationSeries description: Wilo-Drain MTC
H/m Series description: Wilo-Drain MTC Wilo-Drain MTC 50 40 30 20 10 0 Design Submersible sewage pump with external macerator for intermittent and permanent operation, made of grey cast iron for stationary
More informationVERTICAL MULTI-STAGES CENTRIFUGAL PUMPS
Installation and Operating Instructions VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90, 120, 150 1. Model numbering and nameplate format 1.1 Model numbering Example:
More informationCompact System NRGS 11-2 NRGS Original Installation Instructions English
Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive
More informationTechnical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.
Technical Data DML Submersible Sewage s with Single Channel Impeller AUSTRALIA PTY. LTD. DML_Techdata_SS_V Contents -SPECIFICATIONS FEATURES & APPLICATIONS TYPICAL EXPLODED VIEW SPECIFICATIONS SELECTION
More informationData sheet: Wilo-Drain TP 65 F 91/11 (1~230 V)
Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V) Pump curves Wilo-Drain TP 65 F - 50 Hz - 2900 rpm Unit Max. delivery head H max 9.5 m Max. volume flow Q max 36 m 3 /h Optimal delivery head H opt 6.0 m Optimum
More informationService instructions. Contents AMD Hz 3~
Service instructions AMD.07.18.1410.3 50 Hz 3~ Contents 1. Type identification... 2 1.1 Nameplate...2 1.2 Type key...2 2. Torques... 3 3. Service tools...4 3.1 Special tools...4 3.2 Standard tools...4
More informationOperation & Maintenance Manual
Operation & Maintenance Manual Submersible cutter pumps type DSP22 WETTERFRETTER 2.0 Explosion proof version Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398 P. O. Box 199
More informationECOMIX RW Compact, versatile submersible mixers with a wide range of applications including use in aggessive and abrasive liquids
ECOMIX RW 00 900 Compact, versatile submersible mixers with a wide range of applications including use in aggessive and abrasive liquids Can be used in every shape of tank Energy saving selfcleaning propeller
More informationSUBMERSIBLE PUMPS Lifting of wastewater containing little pollution 50 Hz
OPerating limits Flows rates up to : 1 m 3 /h Heads up to : m Temperature range : + 3 to 35 C Free passage : 10 mm ND of discharge orifice R1 1/ SBS--0 JETSON SUBMERSIBLE PUMPS Lifting of wastewater containing
More informationVERTICAL MULTI-STAGE CENTRIFUGAL PUMPS
Installation and Operating Instructions VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90 1. Model numbering and nameplate format 1.1 Model numbering Example: SBI / SBN
More informationSMD, SMG, SFG Mixers and flowmakers
GRUNDFOS INSTRUCTIONS SMD, SMG, SFG Mixers and flowmakers 50 Hz Installation and operating instructions Installation and operating instructions http://net.grundfos.com/qr/i/98826058 English (GB) English
More informationAGRICULTURE AGITATORS
AGITATORS Our service range Tractor-driven agitator GIANTMIX For open and closed tanks - GIANTMIX Z3 / Z4 / Z5 / Z6 Z3 GIANTMIX Z3 Tube Ø 100 x 3 mm, galvanized Tube length 3.5-5.5 m Propeller Ø 480-580
More informationOperating manual Separator
Operating manual Separator Sheet no. AS/4.1.141.1.1 issue 20.08.2014 Contents Section Title Page 0 Introduction... 1 1 Intended use......1 2 Marking of the fitting... 1 3 Safety instructions... 2 4 Transport
More informationOperation & Maintenance Manual
Operation & Maintenance Manual Submersible pumps type LANDY DTP Explosion proof version Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398 P. O. Box 199 info@landustrie.nl
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3
More informationOperation & Maintenance Manual
Operation & Maintenance Manual Submersible pumps type LANDY DWP & Submersible pumps type LANDY DNP Explosion proof version Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398
More informationFlygt /181. Parts List
Flygt 057.09/8 Parts List Table of Contents Table of Contents Introduction... Purpose of this manual... Disclaimer... Data for ordering spare parts... Specially approved products... Qualification of personnel...
More informationEbara Submersible Sewage Pumps (Single Channel Impeller)
Ebara Submersible Sewage Pumps (Single Channel Impeller) Features and Applications Model DML 50Hz + Features! Non-clog single channel impeller Non-clog single channel impeller has 3 spherical passage and
More informationHAZMAT PUMPS TUP, GUP, IN EX explosion proof up to 620 l/min, up to 2.0 bar
HAZMAT PUMPS TUP, UP, IN EX explosion proof up to 620 l/min, up to 2.0 bar Hazmat pumps TUP acc. to DIN 14 424, protection class EEx II 2 c IIB T3 for inflammable and non-aggressive liquids TUP 2-1 TUP
More informationSeries description: Wilo-Drain STS 40
Series description: Wilo-Drain STS H/m 12 Wilo-Drain STS 1 8 6 2 2 6 8 1 12 1 16 Q/m³/h Design Submersible sewage pump Application Pumping of heavily contaminated fluids for: Domestic and site drainage
More informationLinear Valve Electric Actuator
Linear Valve Electric Actuator www.powervalves.nl Company Profile Company Profile Sun Yeh Electrical Ind. Co., Ltd. was founded in 1986. We always strive for technical excellence, innovation and the highest
More informationHIB Enclosed Inverter User Guide
HIB Enclosed Inverter User Guide (0.75kW~22kW) V1.2.0 Contents 1 Safety information...1 2 Technical Data...2 3 Motor Connection...4 4 Operation...5 5 Single phase circuit diagram...7 6 Three phase circuit
More informationMixer Model GF-37 INSTALLATION OPERATION AND MAINTENANCE MANUAL
Mixer Model GF-37 INSTALLATION OPERATION AND MAINTENANCE MANUAL Document Ref M-004 Rev 0 June 2004 Contents 1 - General Instructions GF 37 Gear Drive Portable Mixer Drawing No H-3022-1 1.1 Inspection 1.2
More informationIndustrial air coolers for cooling & freezing applications Cu/Al
Goedhart VCI Industrial air coolers for cooling & freezing applications Cu/Al R404A - CO 2 engineering for a better world GEA Heat Exchangers Goedhart VCI The extensive range Goedhart VCI single discharge
More informationInstallation and Operating Instructions
Submersible Sewage Pump Type ABS XFP-PE4 to PE6 Submersible Mixed Flow Column Pump Type ABS AFLX-PE4 to PE6 Submersible Propeller Pump Type ABS VUPX-PE4 to PE6 2500-0001 1 597 2500 EN 03.2017 en Installation
More informationPAB Atex-certified centrifugal pumps
1 6036 EN PAB Atex-certified centrifugal pumps Technical data Delivery rate Q max = 305 l/min Delivery head H max = 20 m Temperature range 0 C to +60 C Quality Management DIN EN ISO 9001: 2008 Environmental
More informationVolute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M
Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive Series CNI-M Usage For pumping toxic, volatile, explosive or other fluids harmful to the environment which call for service of hermetically
More information- continuos running: max ±5%. - intermittent running: max ±10%. Voltage imbalance between phases: max 2%. Maximum number of starts per hour: 30.
Submersible Electric Pumps GLS Series MARKET SECTORS RESIDENTIAL AND COMMERCIAL BUILDINGS, INDUSTRIES. APPLICATIONS Submersible pump for pumping clean water, surface water and wastewater containing solids
More informationAU DU PONT DE LUTTRE BRUSSELS BELGIUM PHONE: FAX: OPERATING MANUAL. Electric Fully Automatic Floor Saw FS 1218 EX
AU DU PONT DE LUTTRE 74-1190 BRUSSELS BELGIUM PHONE: 322 34 83 162 FAX: 322 34 83 136 OPERATING MANUAL Electric Fully Automatic Floor Saw FS 1218 EX 2 Important information before you start! When the machine
More informationIndustrial air coolers for cooling & freezing applications StSt/Al
Goedhart VRB / VRZ Industrial air coolers for cooling & freezing applications StSt/Al NH 3 - CO 2 engineering for a better world GEA Heat Exchangers Goedhart VRB/VRZ The range Goedhart VRB/VRZ single discharge
More informationSUBMERSIBLE PUMPS EFFLUENT DISPOSAL RANGE 4 poles - 50 Hz
operating limits Flow rates up to: m 3 /h Head up to: m CL Range of temperature of the liquid: +3 to C* Density of the liquid:,5 max. ph of the liquid: 3- Maximum immersion: Maximum particle size: m Ø
More informationOverload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview
SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors.
More informationInstruction Manual. * We reserve the right to amend specification without prior notice.
An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP INDRA HYDR TECH PUMPS PVT. LTD. 16, 1st Floor, th Cross, 4th Phase, Peenya Industrial Area, Bengaluru
More informationDRAINAGE PUMPS Type RLV
DRAINAGE PUMPS Type RLV Owner s manual Identification Each pump has his code engraved on the nameplate. Type Serial V Pn-kW A Q l/1 O IP H mo µf RPM Hz kg Year fabriquant Type Code Serial Serial V nominal
More informationHOMA Product Range. Electric Submersible Sewage Pumps Ranges K, KX. The source for world wide pump technology. Discharge Size DN 200 up to DN 400
The source for world wide pump technology HOMA Product Range Electric Submersible Sewage Pumps Ranges K, KX Submersible drainage pumps Contractor pumps Drainage pumps for emergency application Deepwell
More informationRevision 1.0 Parts List Master
Revision.0 www.grindex.com Parts List 805.8 Master Table of Contents Table of Contents Introduction... Specially products... Product Description...3 The data plate...3 Parts... 4 Exploded view... 4 List
More informationDeepika Enterprises.
+91-8048572696 Deepika Enterprises https://www.deepikaenterprises.co.in/ We are prominent suppliers, traders, wholesalers and distributors of an extensive range of Electrical and Automation Products. Owing
More informationMounting & Maintenance Instructions OMT1 & OMT2 Motors
Mounting & Maintenance Instructions OMT1 & OMT2 Motors Seite 1 von 10 Inhalt Seite 1 General information 3 2 Delivery 3 3 Mounting 3 4 Coupling 3 4.1 Direct coupling 3 4.2 Indirect coupling 4 4.2.1 Flat
More informationGRUNDFOS PRICE LIST 2017 WASTEWATER. Effective date: January 1, 2017
GRUNDFOS PRICE LIST 2017 WASTEWATER 2017 Effective date: January 1, 2017 TABLE OF CONTENTS WASTEWATER SMALL AND LARGE PUMPS, CONTROLS & ACCESSORIES WASTEWATER LARGE SEG Type Key...4-1 SEG Submersible Grinder
More informationJUNG PUMPEN MULTICUT SEWAGE PUMPS
APPLICATION Centrifugal submersible sewage pumps fitted with the MultiCut cutting system are used as stationary appliances for backpressure protection of detached houses. They are suitable for pumping
More informationInstruction Manual. * We reserve the right to amend specification without prior notice.
An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP Declaration of Conformity Company Name Indra Hydro Tech Pumps Pvt. Ltd. Address 16, 4th Phase, th Cross,
More informationSeries description: Wilo-Drain TM/TMW/TMR 32
Series description: Wilo-Drain TM/TMW/TMR 32 H[m] 10 Wilo-Drain TM /TMR /TMW 32 8 6 TM 32/7 4 TM 32/8 TMW 32/8 2 TMW 32/11 TMR 32/8 TMR 32/11 0 0 2 4 6 8 10 12 Q[m³/h] Design Basement drainage pump, water-cooled
More informationASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS INSTRUCCIONES DE SERVICIO OPERATING INSTRUCTIONS 2016
ASYNCHRONOUS INSTRUCCIONES DE SERVICIO MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS OPERATING INSTRUCTIONS 2016 3006/16 en Ed.02.2016 Read these Operating Instructions before you transport,
More informationReg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 Equipment: Manufacturer: Type: ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION
More informationOperating Instructions
Operating Instructions Table of contents Table of contents... 1 1. Declaration... 1 2. Warranty and liability... 2 3. Gear description... 2 4. Gear types... 2 5. Safety... 3 5.1 General safety information...
More informationIndustrial air cooler VCI Cooling/Freezing
Industrial air cooler VCI Cooling/Freezing Cu/Al - R404A GEA Refrigeration Goedhart Goedhart VCI The extensive range Goedhart VCI single discharge ceiling mounted industrial air coolers are available with
More informationFlygt /181. Parts List
Flygt 045.091/181 Parts List Table of Contents Table of Contents Introduction... Purpose of this manual... Disclaimer... Data for ordering spare parts... Specially approved products... Qualification of
More informationOperation & Maintenance Manual
Operation & Maintenance Manual Submersible mixers type LANDY DWM & Submersible mixers type LANDY DNM Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398 P. O. Box 199 info@landustrie.nl
More informationROTAX Engine Type 914 F
AIRCRAFT ENGINES ation Manual for ROTAX Engine Type XXX WARNING Before starting with the engine installation, please, read the ation Manual completely as it contains important safety-relevant information.
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5
More informationG72x Series Direct Spark Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G72x Issue Date 1299 G72x Series Direct Spark Ignition Controls Figure 1: G72x Direct Spark Ignition
More informationQAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA
QAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA eltherm Canada Inc. 1440 Graham s Lane, Unit 5 Burlington Ontario L7S 1W3 Canada Phone: +1 (289) 812-6631 Fax: +1 (844) 325-6750 E-Mail:
More informationSIRIUS 3RU2 Thermal Overload Relays
Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to
More informationFlygt low-speed mixers OUTSTANDING EFFICIENCY
Flygt low-speed mixers OUTSTANDING EFFICIENCY INTRODUCTION Energy-efficient mixing Advantages of Flygt low-speed mixers Rising to the mixing challenge All mixing applications require varying degrees of
More informationCENTRIFUGAL IMMERSION PUMPS
CENTRIFUGAL IMMERSION PUMPS FLUX CENTRIFUGAL IMMERSION PUMPS QUALITY THAT SETS STANDARDS Manufactured at our main plant, these ranges of immersion pumps are the result of extensive product and process
More informationData sheet: Wilo-Drain TP 65 F 109/22 (3~400 V)
Data sheet: Wilo-Drain TP 65 F 109/22 (3~400 V) Pump curves Wilo-Drain TP 65 F - 50 Hz - No. of poles: 2 Unit Max. delivery head H max 14.5 m Max. volume flow Q max 52.0 m 3 /h Optimal delivery head H
More informationSL1, SLV kw, 50 Hz GRUNDFOS INSTRUCTIONS. Service instructions
GRUNDFOS INSTRUCTIONS SL1, SLV 1.1-11 kw, 50 Hz Service instructions Installation and operating instructions in English and other languages for 50 Hz http://net.grundfos.com/qr/i/96771279 English (GB)
More informationNo: En Revision Parts List. MINEX O-RING KIT BASIC REPAIR KIT E_8101_171_expl_view
No: 89850 En Revision 6.0 0 0 Parts List MINEX 80.7 www.grindex.com O-RING KIT BASIC REPAIR KIT 0008E_80_7_expl_view Parts List MINEX 80.7 Overview Table of Contents This publication contains the following
More informationFor Operation in the Control Cabinet 3RW Soft Starters
General Data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations
More informationNB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS
NB 0811 - NB 1511 NB 0831 - NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS LEN.MAN.UPS.069 Rev.2.00/2002 CONTENTS Safety Instructions 1 Introduction 3 2.1 FEATURE 3 2.2 UPS modules 4 How the UPS works 5 3.1
More informationParts List. MINOR
No: 88600 En Revision 3.0 0 Parts List MINOR 803.80 www.grindex.com 5 8 8 6 7 8 O-RING KIT 80 BASIC REPAIR KIT 90 6-68 5 6 7 9 0 50-5 3 5 6 7 8 9 30 300 39-35 85 303 86 3 33 3 35 36 37 38 83 39 0 8 N 68
More informationQuality wins through!
Components for biogas Quality wins through! Offer benefits Harvest profits with Eisele More than 25 years of experience with Biogas plants The robust and powerful pumps and submersible mixers of EISELE
More informationType Type 1001 Transducers. I/P & E/P Transducers
Type 1001 I/P & E/P Description The Type 1001 is a patented family of electropneumatic instruments that is used to reduce a supply pressure to a regulated output pressure which is directly proportional
More informationSERVICE MANUAL SECOH AIR PUMPS
SERVICE MANUAL SECOH AIR PUMPS (SHOWN AT EL SERIES) MODEL: SLL-20, 30, 40 & 50 EL-60, 80-15, 80-17 & 100 EL-120W, 150 & 200-0 - This manual is not meant to be included in the scope of delivery (for this
More informationSewage transport Submersible pumps
Series description Wilo-Rexa FIT Available from January 2012 Construction Submersible sewage pump with cast iron hydraulics and stainless steel motor Type key Example: Wilo Rexa FIT V06DA-110/EAD1-2-T0015-540-A
More informationAEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1
AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1 STANDARD AND SPECIFICATION Performance: Meet the requirement of Singapore standard
More informationOperating Instructions Flexdip CYA112
BA00432C/07/EN/13.13 71207066 Products Solutions Services Operating Instructions Wastewater assembly About this document Safety messages The structure, signal words and safety colors of the signs comply
More informationDP A.2.50B. Grundfos pump GRUNDFOS DATA BOOKLET
GRUNDFOS DATA BOOKLET DP10.65.26.A.2.50B Grundfos pump 96106544 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/dpfam/96106544/dp10-65-26-a-2-50b.html
More informationParts List. MAJOR
No: 8860 En Revision.0 0.0 Parts List MAJOR 80.80 www.grindex.com 5 8 8 6 7 8 O-RING KIT 80 BASIC REPAIR KIT 90 6-68 5 6 7 9 0 50-5 3 5 6 7 8 9 30 300 39-35 85 303 86 3 33 3 35 36 37 38 83 39 0 8 N 68
More informationFlygt low-speed mixers. outstanding efficiency
Flygt low-speed mixers outstanding efficiency Introduction Energy-efficient mixing Advantages of Flygt low-speed mixers Rising to the mixing challenge All mixing applications require varying degrees of
More informationNo: En Revision Parts List. MAJOR MSHA A_8103_8104_081_expl_view
No: 882089 En Revision 2.0 202.0 Parts List MAJOR MSHA 80.08 www.grindex.com 2 3 5 6 7 8 9 0 7 8 9 2 3 5 6 2 3 5 6 7 8 9 50 5 52 53 20 2 22 23 2 25 26 27 28 29 30 5 55 56 57 58 59 60 6 62 63 500 3 32 33
More informationGerotor pump, fixed displacement volume
Gerotor pump, fixed displacement volume RE 10545/12.11 1/12 Type GZ Component series 1X Maximum operating pressure 15 bar Maximum displacement 140 cm³ H7572_d Table of contents Contents age eatures 1 Ordering
More informationTechnical Data. Dimensions
Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush
More informationPHP-C Pressureless Expansion System Overview Description: The PHP-C balanced pressure expansion equipment is sized according to the total system volume and the boiler or chiller load. The PHP-C vessel
More informationInstallation, Maintenance and Operation manual 4 Submersible sand fighter pump. Type: SSFP - Series
Installation, Maintenance and Operation manual 4 Submersible sand fighter pump Type: SSFP - Series Prakash Pump Warranty We guarantee our products, for the period of 24 months from the date of purchase.
More informationSECTION ELECTRIC MOTOR ACTUATORS FOR VALVES
SECTION 40 92 10 - ELECTRIC MOTOR ACTUATORS FOR VALVES PART 1 - GENERAL A. Description This section includes materials and installation of electric motor actuators for valves. B. Submittals 1. Submit shop
More informationJUNG PUMPEN US SUBMERSIBLE DRAINAGE PUMPS
APPLICATION The centrifugal submersible drainage pumps US 62-251 can be used wherever sewage water with solids up to 10 mm particle size occurs, e.g. in collecting sumps for ground water, or in permanent
More informationSWE SERIES (IE3) WONDER ELECTRIC MOTOR (S) PTE LTD. Energy Saving Low Noise Environmental Friendly IEC Dimension Low Vibration European Design
RANGE OF PRODUCTS Three phase asynchronous squirrel-cage & slip ring induction motors Three phase asynchronous self-braking motors Hollow shaft rotor motors Cooling tower motors High motors, (IE2) (IE3)
More informationAmaline Submersible motor recirculation pump with ECB propeller 50 Hz Applications Designation Amaline P / 74 UM G Pump design
Type series booklet 1594.5/8--EN Amaline Submersible motor recirculation pump with ECB propeller Hz Applications Recirculation of activated sludge from nitrification stages into denitrification stages
More informationACCESSORIES CATALOGUE
ACCESSORIES CATALOGUE Spray technology Fluid handling Material extrusion Injection www.wiwa.com 1 WIWA ram presses and single post lifts 1.1 WIWA single and twin post ram presses WIWA holder for ram presses
More informationTPAK Series COOLANT PUMP
TPAK Series COOLANT PUMP Instruction Manual ISO 9001 Certified WALRUS PUMP CO., LTD. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No.83-14, Dapiantou, Sanzhi Dist., New Taipei
More informationSP A, SP. Submersible pumps Submersible motors Accessories. 50 Hz
SP A, SP Submersible motors Accessories For raw water supply, irrigation systems, groundwater lowering, pressure boosting and various industrial applications. 5 Hz TM 7318 2298 Contents General data Performance
More informationInstallation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps
Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps EI-700-008 Rev -- Table of Contents Safety Guidelines 3 Caution 4 Wiring 4 Maintenance 4 Nameplate format 4 Prior to Operation
More informationOrbipore CPS91 and CPS91D
Technical Information Orbipore CPS91 and CPS91D ph electrodes, analog or with digital Memosens technology With open aperture for heavily soiled media, optional built-in temperature sensor Application Chemical
More information3RW Soft Starters. General data. 6/4 Siemens LV
General data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of peaks Avoidance of mains voltage fluctuations during starting
More informationBorehole Submersible Pumps. Installation and Operating Instructions
Borehole Submersible Pumps Installation and Operating Instructions These instructions apply to STAIRS submersible pumps, type SP. Read these instructions carefully before beginning installation 1. Delivery
More informationNo: En Revision Parts List. MINETTE O-RING KIT BASIC REPAIR KIT F_8102_171_expl_view
No: 89837 En Revision 6.0 202 0 Parts List MINETTE 802.7 www.grindex.com O-RING KIT BASIC REPAIR KIT 2002F_802_7_expl_view Parts List MINETTE 802.7 Overview Table of Contents This publication contains
More informationOperating instructions for PXFLOW sewage pumps
Operating instructions for PXFLOW sewage pumps Standard units PAPANTONATOS S.A. Roumelis & Kapetan Zacharia (ex. Afon Ntouna) 1 13677 Acharnes Attiki - Greece Tel: (+30) 210 2431111, FAX: (+30) 210 2431601
More information