Flygt /181. Parts List

Size: px
Start display at page:

Download "Flygt /181. Parts List"

Transcription

1 Flygt /8 Parts List

2 Table of Contents Table of Contents Introduction... Purpose of this manual... Disclaimer... Data for ordering spare parts... Specially approved products... Qualification of personnel... Dimensional accuracy inspection... Product Description... The data plate... Approvals...4 Product approvals for hazardous locations...4 EN approval plate...4 IEC approval plate...4 FM approval plate...5 Product denomination...5 Drive and Hydraulic Units...7 CP...7 CS...9 CF... DP... DS...5 DF...9 List of parts, drive unit... List of parts, hydraulic unit...8 Installation Components...0 CP/DP...0 CP/DP... CP/DP... CF/CS/DF/DS... CF/CS/DF/DS...4 List of parts...5 Service Parts...7 List of parts...7 Flygt /8 Parts List

3 Introduction Introduction Purpose of this manual The purpose of this manual is to provide necessary information on spare parts and accessories order. Disclaimer Always use genuine Flygt parts. The use of other spare parts or accessories can invalidate any claims for warranty or compensation. Xylem does not take any responsibility for damages that are caused by the use of non-original parts. For more information, contact your local sales and service representative. Data for ordering spare parts The following information is needed for spare part orders: Serial number of the product Part number Quantity of bulk material, see * in tables Specially approved products Qualification of personnel Dimensional accuracy inspection Only Xylem or Xylem-authorized service personnel may undertake repair work on Exapproved products. Spare parts marked with (Ex) after the part number are subject to dimensional accuracy inspection. Flygt /8 Parts List

4 Product Description Product Description The data plate The data plate is a metal label that is located on the main body of the products. The data plate lists key product specifications. Specially approved products also have an approval plate Curve code or Propeller code. Serial number, see Product denomination (page 5). Product number 4. Country of origin 5. Additional information 6. Phase; type of current; frequency 7. Rated voltage Thermal protection 0. Thermal class. Rated shaft power. International standard. Degree of protection 4. Rated current 5. Rated speed 6. Maximum submergence 7. Direction of rotation: L=left, R=right 8. Duty class 9. Duty factor 0. Product weight. Locked rotor code letter. Power factor. Maximum ambient temperature 4. Read installation manual 5. Notified body, only for EN-approved Ex products Figure : The data plate WS00657A Flygt /8 Parts List

5 Product Description Approvals Product approvals for hazardous locations Pump Approval European Norm (EN) ATEX Directive EN , EN , EN 7- II G Ex d IIB T4 EN approval for cable entry: Certificate number: INERIS 0ATEX9008 U II G Ex d IIC or I M Ex d I FM (FM Approvals) Explosionproof for use in Class I, Div., Group C and D Dust ignition proof for use in Class II, Div., Group E, F and G Suitable for use in Class III, Div., Hazardous Locations EN approval plate This illustration describes the EN approval plate and the information that is contained in its fields WS0097A. Approval. Approval authority and Approval number. Approval for Class I 4. Approved for drive unit 5. Stall time 6. Starting current or Rated current 7. Duty class 8. Duty factor 9. Input power 0. Rated speed. Controller. Additional information. Maximum ambient temperature 4. Serial number 5. ATEX marking IEC approval plate This illustration describes the IEC approval plate and the information that is contained in its fields. International Norm; not for EU member countries. 4 Flygt /8 Parts List

6 Product Description WS0079B. Approval. Approval authority and Approval number. Approved for drive unit 4. Stall time 5. Starting current or Rated current 6. Duty class 7. Duty factor 8. Input power 9. Rated speed 0. Controller. Additional information. Maximum ambient temperature. Serial number FM approval plate This illustration describes the FM approval plate and the information that is contained in its fields.. Temperature class. Maximum ambient temperature WS0097A Product denomination Reading instruction Codes and parameters In this section, code characters are illustrated accordingly: X = letter Y = digit The different types of codes are marked up with a, b and c. Code parameters are marked up with numbers. XXYYYY. YYY YYY YYYY a b c WS00665B Flygt /8 Parts List 5

7 Product Description Type of Callout Number Indication Type of code a Sales denomination b Product code c Serial number Parameter Hydraulic end Type of installation Sales code 4 Version 5 Production year 6 Production cycle 7 Running number 6 Flygt /8 Parts List

8 Drive and Hydraulic Units CP CP Flygt /8 Parts List 7

9 CP Flygt /8 Parts List

10 CS CS Flygt /8 Parts List 9

11 CS Flygt /8 Parts List

12 CF CF Flygt /8 Parts List

13 CF Flygt /8 Parts List

14 DP DP Flygt /8 Parts List

15 DP Flygt /8 Parts List

16 DS DS Flygt /8 Parts List 5

17 DS ARV Flygt /8 Parts List

18 DS Flygt /8 Parts List 7

19 DS ARV Flygt /8 Parts List

20 DF DF Flygt /8 Parts List 9

21 DF ARV Flygt /8 Parts List

22 DF Flygt /8 Parts List

23 DF ARV Flygt /8 Parts List

24 List of parts, drive unit Pos. No Part. No Denomination Qty/Version Lifting handle VA 8 00 Hex.socket hd screw M6X6-A Data plate USE AS SPARE PART Instruction plate Canada Instruction plate Sticker Name plate Hex.socket hd screw M6X-A Drive screw 4X5-A/A Stator housing Stator housing Motor -08-BB (Ex) Stator housing Motor -0-BZ Hex.socket hd screw M8X5-A4-80, Cap 5X0 MM PVC, Closed end splice (AWG -8) L=8, Insulating hose pvc Diameter = mm *, Insulating hose pvc Diameter = 8 mm *, Tape *, Closed end splice -6(AWG -0) L= Plate HOT WATER PRODUCT Certificate plate EX (Ex) Certificate plate IECEX PLATE Certificate plate FM Marking tape 89 HIGH TACK/ Connection plate O-ring 56X FPM 7 8 Ball bearing 604-Z/CWT 0X5X (Ex) Shaft unit -POL -PHASE 80 MM Stator -phase 50Hz -poles 80V-400V Y 0V-0V D P=,7kW Max ambient temp=40 DC Thermal contact 5 DC. Stator -phase 50Hz -poles 80V-400V Y 0V-0V D P=,7KW Max ambient temp=70 DC Thermal contact 5 DC. Stator -phase 60Hz -poles 460V-480V Y P=kW/,7hp Max ambient temp=40 DC Thermal contact 5 DC Flygt /8 Parts List

25 Pos. No Part. No Denomination (Ex) Shaft unit -POL -PHASE 00 MM Stator -phase 60Hz -poles 0V-40V P=,7kW/,hp Max ambient temp=40 DC Thermal contact 5 DC (Ex) Shaft unit -PHASE -POL 00 MM Stator -phase 50Hz -poles 80V-400V Y 0V-0V D P=,4kW Max ambient temp=40 DC Thermal contact 5 DC. Stator -phase 60Hz -poles 460V-480V Y P=,8KW Max ambient temp=70 DC Thermal contact 5 DC. Stator -phase 50Hz -poles 80V-400V Y 0V-0V D P=,4KW Max ambient temp=70 DC Thermal contact 5 DC. Stator -phase 60Hz -poles 460V-480V Y P=,8kW/,8hp Max ambient temp=40 DC Thermal contact 5 DC Shaft unit -PHASE -POL 00 MM Stator -phase 50Hz -poles 80V-400V Y 0V-0V D P=,4kW Max ambient temp=40 DC Thermal contact 5 DC. Stator -phase 60Hz -poles 460V-480V Y P=,8KW Max ambient temp=70 DC Thermal contact 5 DC. Stator -phase 50Hz -poles 80V-400V Y 0V-0V D P=,4KW Max ambient temp=70 DC Thermal contact 5 DC. Stator -phase 60Hz -poles 460V-480V Y P=,8kW/,8hp Max ambient temp=40 DC Thermal contact 5 DC Qty/Version (Ex) Shaft unit -POL -PHASE 80 MM Motor -08-BB (Ex) Shaft unit -POL -PHASE 00 MM Motor -0-BZ (Ex) Shaft unit -PHASE -POL 00 MM Motor -0-BB Shaft unit -PHASE -POL 00 MM Motor -0-BBARV (Abrasion resistant version) Stator -08-b -phase 50Hz -poles 80V-400V Y 0V-0V D P=,7kW Max ambient temp=40 DC Thermal contact 5 DC. -phase 50Hz -poles 80V-400V Y 0V-0V D P=,7KW Max ambient temp=70 DC Thermal contact 5 DC. -phase 60Hz -poles 460V-480V Y P=kW/,7hp Max ambient temp=40 DC Thermal contact 5 DC Stator -08-b -phase 50Hz -poles 80V-400V Y P=,7kW Max ambient temp=40 DC Thermal contact 5 DC *** -stator leads ***. -phase 60Hz -poles 440V-480V Y P=kW/,7hp Max ambient temp=40 DC Thermal contact 5 DC *** -stator leads *** Stator -08-b -phase 50Hz -poles 45V-440V Y P=,7kW Max ambient temp=40 DC Thermal contact 5 DC 4 Flygt /8 Parts List

26 Pos. No Part. No Denomination Stator -08-b -phase 50Hz -poles 500V-550V Y P=,7kW Max ambient temp=40 DC Thermal contact 5 DC. -phase 60Hz -poles 575V-600V Y P=kW/,7hp Max ambient temp=40 DC Thermal contact 5 DC Stator -08-b -phase 50Hz -poles 690V Y 400V D P=,7kW Max ambient temp=40 DC Thermal contact 5 DC Stator -08-b -phase 60Hz -poles 460V YSER 0V Y// P=kW/,7hp Max ambient temp=40 DC Thermal contact 5 DC Stator -08-b -phase 50Hz -poles 90V-00V Y P=,7kW Max ambient temp=40 DC Thermal contact 5 DC. -phase 60Hz -poles 00V-0V Y P=kW/,7hp Max ambient temp=40 DC Thermal contact 5 DC Stator -08-b -phase 60Hz -poles 80V Y 0V D P=kW/,7hp Max ambient temp=40 DC Thermal contact 5 DC (Ex) Stator -0-b -phase 60Hz -poles 0V-40V P=,7kW/,hp Max ambient temp=40 DC Thermal contact 5 DC Stator -0-b -phase 50Hz -poles 80V-400V Y 0V-0V D P=,4kW Max ambient temp=40 DC Thermal contact 5 DC. -phase 60Hz -poles 460V-480V Y P=,8KW Max ambient temp=70 DC Thermal contact 5 DC. -phase 50Hz -poles 80V-400V Y 0V-0V D P=,4KW Max ambient temp=70 DC Thermal contact 5 DC. -phase 60Hz -poles 460V-480V Y P=,8kW/,8hp Max ambient temp=40 DC Thermal contact 5 DC (Ex) Stator -0-b -phase 50Hz -poles 80V-45V Y P=,4kW Max ambient temp=40 DC Thermal contact 5 DC *** -stator leads ***. -phase 60Hz -poles 440V-480V Y P=KW Max ambient temp=70 DC Thermal contact 5 DC *** -stator leads ***. -phase 50Hz -poles 80V-45V Y P=,KW Max ambient temp=70 DC Thermal contact 5 DC *** -stator leads ***. - phase 60Hz -poles 440V-480V Y P=,8kW/,8hp Max ambient temp=40 DC Thermal contact 5 DC *** -stator leads *** Stator -0-b -phase 50Hz -poles 45V-440V Y P=,4kW Max ambient temp=40 DC Thermal contact 5 DC. -phase 50Hz -poles 45V-440V Y P=,4KW Max ambient temp=70 DC Thermal contact 5 DC Qty/Version 098 Flygt /8 Parts List 5

27 Pos. No Part. No Denomination Stator -0-b -phase 50Hz -poles 500V-550V Y P=,4kW Max ambient temp=40 DC Thermal contact 5 DC. -phase 60Hz -poles 575V-600V Y P=,8KW Max ambient temp=70 DC Thermal contact 5 DC. -phase 50Hz -poles 500V-550V Y P=,4KW Max ambient temp=70 DC Thermal contact 5 DC. -phase 60Hz -poles 575V-600V Y P=,8kW/,8hp Max ambient temp=40 DC Thermal contact 5 DC Stator -0-b -phase 50Hz -poles 690V Y 400V D P=,4kW Max ambient temp=40 DC Thermal contact 5 DC. -phase 50Hz -poles 690V Y 400V D P=,4KW Max ambient temp=70 DC Thermal contact 5 DC Stator -0-b -phase 60Hz -poles 460V YSER 0V Y// P=,8KW Max ambient temp=70 DC Thermal contact 5 DC. -phase 60Hz -poles 460V YSER 0V Y// P=,8kW/,8hp Max ambient temp=40 DC Thermal contact 5 DC Stator -0-b -phase 50Hz -poles 90V-00V Y P=,4kW Max ambient temp=40 DC Thermal contact 5 DC. -phase 60Hz -poles 00V-0V Y Max P=,9KW Max ambient temp=70 DC Thermal contact 5 DC. -phase 50Hz -poles 90V-00V Y P=,4KW Max ambient temp=70 DC Thermal contact 5 DC. -phase 60Hz -poles 00V-0V Y P=,8kW/,8hp Max ambient temp=40 DC Thermal contact 5 DC Stator -0-b -phase 60Hz -poles 80V Y 0V D P=,8KW Max ambient temp=70 DC Thermal contact 5 DC. -phase 60Hz -poles 80V Y 0V D P=,8kW/,8hp Max ambient temp=40 DC Thermal contact 5 DC Stator -0-b -phase 60Hz -poles 08V Y P=,8KW Max ambient temp=70 DC Thermal contact 5 DC. -phase 60Hz -poles 08V Y P=,8kW/,8hp Max ambient temp=40 DC Thermal contact 5 DC (Ex) Stator -0-b -phase 50Hz -poles 0V-40V P=,5kW Max ambient temp=40 DC Thermal contact 5 DC Qty/Version Insulating hose DIAM=0, L=90 MM Cable tie 00X.4 PA 6/ Motor cable subcab 4G.5+X.5 OD= Motor cable subcab 7G.5+X.5 MM OD=0- * * * * 6 Flygt /8 Parts List

28 Pos. No Part. No Denomination Motor cable subcab SX,5+X,5/+S(4X0.5) Motor cable subcab 4G.5+X.5 OD = 7-8 MM Motor cable subcab 4G4+X.5 OD=0- MM Motor cable subcab 4G.5 OD = MM Motor cable subcab 4G.5 OD=.5-.5 MM Motor cable subcab 4G.5+X.5 OD = 7-8 MM Motor cable silicone 4G.5 OD = MM Qty/Version 098 4, Cutting screw TAPTITE-M6X 4, Cable lug INSUL.UL/CSA MM 4, Terminal block conductors 8 4 4, Terminal block conductors 5 5 4, Closed end splice ;(AWG 8-8) L=8 4, Closed end splice -6(AWG -0) L=8 4, (Ex) Gland screw FOR CABLE ENTRY 4, Cable lug mm; M6 4, Cable lug.5-6 MM;M6 * * * * * * * 4, (Ex) Gland screw FOR CABLE ENTRY Plain washer 6-A Cable unit Leakage detect.unit (FLS) (Ex) Bearing holder GG Bearing holder GG Ball bearing 05A-Z/CVT O-ring 59.5X FPM (Ex) Bearing cover Mechanical seal ALO/CARBON Mechanical seal WCCR/WCCR Oil housing bottom COATED NBR M8 THREADED Drive and Hydraulic Units O-ring.X.4 FPM Hex.socket hd screw Mechanical seal WCCR/ALO Mechanical seal WCCR/WCCR Flygt /8 Parts List 7

29 Pos. No Part. No Denomination Qty/Version Mechanical seal WCCR/WCCR Gland screw Plain washer 0-A Ring 9 84 Level switch Clip DIAM Hexagon nut M4-A Protective cap Slotted head screw M4X0-A Retaining ring SGH Sealing washer DUBO NR Connection plate Sticker Plain washer (0)- MM Plain washer (0)- MM Seal sleeve (4)-6 MM Seal sleeve (6)-8 MM Seal sleeve (8)-0 MM Seal sleeve (0)- MM Seal sleeve (0)- MM Seal sleeve (0)- MM Seal sleeve ()-4 MM Seal sleeve (0)- MM (Ex) Cable clip (4)-6 MM (Ex) Cable clip (6)-8 MM (Ex) Cable clip (8)-0 MM (Ex) Cable clip (0)- MM (Ex) Cable clip (0)- MM (Ex) Cable clip ()-4 MM (Ex) Cable clip (0)- MM List of parts, hydraulic unit Pos. No Part. No Denomination Qty/Version Hex.socket hd screw M6X5-A Sleeve Torque flow impeller Medium head "D-MT", Curve no: 0, 50 Hz, -phase 8 Flygt /8 Parts List

30 Pos. No Part. No Denomination Torque flow impeller Medium head "D-MT", Curve no:, 50/60 Hz, -phase Torque flow impeller Medium head "D-MT", Curve no: 4, 50/60 Hz, -phase / -phase Torque flow impeller Medium head "D-MT", Curve no: 6, 60 Hz, -phase / -phase Impeller compl. High head "C-HT", Curve no: 60, 50 Hz, -phase, Stainless steel Impeller High head "C-HT", Curve no: 6, 50 Hz, -phase, Stainless steel Impeller High head "C-HT", Curve no: 64, 60 Hz, -phase, Stainless steel Impeller compl. High head "C-HT", Curve no: 66, 50/60 Hz, -phase / -phase, Stainless steel Torque flow impeller Medium head "D-MT", Curve no: 70, 50 Hz, -phase, Abrasion resistant Torque flow impeller Medium head "D-MT", Curve no: 7, 50/60 Hz, -phase, Abrasion resistant Torque flow impeller Medium head "D-MT", Curve no: 74, 60 Hz, -phase, Abrasion resistant Torque flow impeller Medium head "D-MT", Curve no: 8, 50 Hz, -phase Pump housing HT MT C D DN 50 ISO G Mtrl: Grey cast iron Installation: F. Pump housing C D DN 50 ISO G Installation: F Qty/Version Pump housing C D DN 50 -/ NPT Installation: F Pump housing HT MT C D DN 50 Sliding bracket Installation: P. C D DN 50 Sliding bracket Installation: P 67, Seal ring PERBUNAN, GREY Pump housing MT D DN 50 ISO G Mtrl: Hardened cast iron for heavily contaminated water Installation: F Hex.socket hd screw M8X0-A Slotted head screw M6X0-A Strainer bottom POLYETHYL. PEHD Suction cover D-impeller MT 50Hz -phase Max ambient temp=40 DC Mtrl. Grey cast iron. D-impeller MT 50Hz -phase Max ambient temp=40 DC Mtrl. Grey cast iron Suction cover C-impeller HT 50Hz -phase Max ambient temp=40 DC Mtrl. stainless steel (ASTM 04) Drive and Hydraulic Units O-ring 54.X5.7 NBR Flygt /8 Parts List 9

31 Installation Components Installation Components CP/DP Twin guide bars CP/DP Flygt /8 Parts List

32 Installation Components CP/DP Coupling CP/DP Flygt /8 Parts List

33 Installation Components CP/DP TOP CP/DP 045/057 TOP 50/ Flygt /8 Parts List

34 Installation Components CF/CS/DF/DS Hose CF/CS/DF/DS 045/ Flygt /8 Parts List

35 Installation Components CF/CS/DF/DS Quick coupling CF/CS/DF/DS 045/ Flygt /8 Parts List

36 Installation Components List of parts Pos. No Part. No Denomination Discharge connection IN/OUT 50/50 MM Discharge connection IN/OUT 50/50 MM Installation P Hydraulic: C D Thread : ISO G Inner DN 50 Ordered separately Installation P Hydraulic: C D Thread : NPT -/ Inner DN 50 Ordered separately Discharge con.stat. IN/OUT 50/50 MM TOP 50 TOP 65 Installation P Thread : ISO G Inner DN 50 Ordered separately Discharge con.stat. IN/OUT 50/50 MM TOP 50 TOP 65 Installation P Thread : NPT -/ Inner DN 50 Ordered separately Discharge con.stat. IN/OUT 50/R" Installation P Hydraulic: C D Thread : ISO G Inner DN 80 Ordered separately Discharge connection NPT -8 Installation P Hydraulic: C D Thread : -8 NPT Inner DN 50 Ordered separately Qty/Version Guide bracket unit SS Discharge connection 08, 8 4 Hexagon head screw M0X0-A-70 08, 8 4 Hexagon head screw M0X0-A-70 08, 8 Hexagon nut M0-A ,4 8 5 Shackle 08, O-ring 08, Muff 08, Bush 08, Clamping piece Nipple pipe CONN. 80 GALV Flange DN Coupling Discharge connection polyamid Installation: S, F for hose Hydraulic: C D DN 50 Thread : NPT -/ Coupling POLYPROPYLENE PP R Discharge connection Installation F For hose DN 50 DN Discharge connection THREAD "FOR HOSE INTERNA Nipple pipe CONN. 50, L=80 MM Coupling part DN5 INNER GB STORZ 8 9 Coupling part DN5 FOR HOSE " STORZ Clip Clip Hexagon head screw M8X65-A4-70 Flygt /8 Parts List 5

37 Installation Components Pos. No Part. No Denomination Qty/Version Hexagon nut M8-A Plain washer 8-A Starter B Starter B-56-6, Starter B Starter B-5-6, Starter.5 KW 0 V/50 HZ Starter. KW 0 V/60 HZ Plug contact V PH 6A CEE 5P 6 Flygt /8 Parts List

38 Service Parts Service Parts List of parts Pos. No Part. No Denomination Qty/Version O-ring kits /.890 GR Basic repair kit With mechanical seal: ALO/CSB-TYPE O Basic repair kit With mechanical seal: WCCR/CERAMIC Oil * * Flygt /8 Parts List 7

Flygt /181. Parts List

Flygt /181. Parts List Flygt 045.091/181 Parts List Table of Contents Table of Contents Introduction... Purpose of this manual... Disclaimer... Data for ordering spare parts... Specially approved products... Qualification of

More information

Parts List _2.0. Concertor /180

Parts List _2.0. Concertor /180 Parts List 88624_2.0 Concertor 6020.090/80 Table of Contents Table of Contents Introduction... 2. Specially approved products... 2 2 Product Description...3 2. The data plate...3 2.2 Approvals...4 2.3

More information

Flygt Parts List

Flygt Parts List Flygt 2870.80 Parts List Table of Contents Table of Contents Introduction... 2. Specially approved products... 2 2 Product Description...3 2. Products included... 3 2.2 The data plate...3 2.3 Product

More information

Flygt /180/280/290. Parts List

Flygt /180/280/290. Parts List Flygt 3201.091/180/280/290 Parts List Table of Contents Table of Contents Introduction...2 Purpose of this manual...2 Disclaimer...2 Data for ordering spare parts...2 Specially approved products...2 Qualification

More information

Flygt Parts List

Flygt Parts List Flygt 260.7 Parts List Table of Contents Table of Contents Introduction...2 Purpose of this manual...2 Disclaimer...2 Data for ordering spare parts...2 Specially approved products...2 Qualification of

More information

Flygt Parts List

Flygt Parts List Flygt 2670.80 Parts List Table of Contents Table of Contents Introduction...2 Purpose of this manual...2 Disclaimer...2 Data for ordering spare parts...2 Specially approved products...2 Qualification

More information

Flygt /095/181/185. Parts List

Flygt /095/181/185. Parts List Flygt 3171.091/095/181/185 Parts List Table of Contents Table of Contents Introduction...2 Purpose of this manual...2 Disclaimer...2 Data for ordering spare parts...2 Specially approved products...2 Qualification

More information

Revision 1.0 Parts List Master

Revision 1.0 Parts List Master Revision.0 www.grindex.com Parts List 805.8 Master Table of Contents Table of Contents Introduction... Specially products... Product Description...3 The data plate...3 Parts... 4 Exploded view... 4 List

More information

Revision 1.0 Parts List Maxi Lite

Revision 1.0 Parts List Maxi Lite Revision.0 www.grindex.com Parts List 807.300 Maxi Lite Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data plate...3

More information

Revision 2.0 Parts List Master

Revision 2.0 Parts List Master Revision.0 www.grindex.com Parts List 805.8 Master Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data plate...3

More information

No: En Revision Parts List. MINEX O-RING KIT BASIC REPAIR KIT E_8101_171_expl_view

No: En Revision Parts List.  MINEX O-RING KIT BASIC REPAIR KIT E_8101_171_expl_view No: 89850 En Revision 6.0 0 0 Parts List MINEX 80.7 www.grindex.com O-RING KIT BASIC REPAIR KIT 0008E_80_7_expl_view Parts List MINEX 80.7 Overview Table of Contents This publication contains the following

More information

No: En Revision Parts List. MINETTE O-RING KIT BASIC REPAIR KIT F_8102_171_expl_view

No: En Revision Parts List.  MINETTE O-RING KIT BASIC REPAIR KIT F_8102_171_expl_view No: 89837 En Revision 6.0 202 0 Parts List MINETTE 802.7 www.grindex.com O-RING KIT BASIC REPAIR KIT 2002F_802_7_expl_view Parts List MINETTE 802.7 Overview Table of Contents This publication contains

More information

Parts List. MINOR

Parts List.  MINOR No: 88600 En Revision 3.0 0 Parts List MINOR 803.80 www.grindex.com 5 8 8 6 7 8 O-RING KIT 80 BASIC REPAIR KIT 90 6-68 5 6 7 9 0 50-5 3 5 6 7 8 9 30 300 39-35 85 303 86 3 33 3 35 36 37 38 83 39 0 8 N 68

More information

No: En Revision Parts List. Matador O-RING KIT BASIC REPAIR KIT B_8106_180_expl_view

No: En Revision Parts List.  Matador O-RING KIT BASIC REPAIR KIT B_8106_180_expl_view No: 897386 En Revision 9.0 0 0 Parts List Matador 806.80 www.grindex.com O-RING KIT 80 BASIC REPAIR KIT 90 90 0086B_806_80_expl_view Parts List Matador 806.80 Overview Table of Contents This publication

More information

Parts List. MAJOR

Parts List.  MAJOR No: 8860 En Revision.0 0.0 Parts List MAJOR 80.80 www.grindex.com 5 8 8 6 7 8 O-RING KIT 80 BASIC REPAIR KIT 90 6-68 5 6 7 9 0 50-5 3 5 6 7 8 9 30 300 39-35 85 303 86 3 33 3 35 36 37 38 83 39 0 8 N 68

More information

No: En Revision Parts List. MAJOR MSHA A_8103_8104_081_expl_view

No: En Revision Parts List.  MAJOR MSHA A_8103_8104_081_expl_view No: 882089 En Revision 2.0 202.0 Parts List MAJOR MSHA 80.08 www.grindex.com 2 3 5 6 7 8 9 0 7 8 9 2 3 5 6 2 3 5 6 7 8 9 50 5 52 53 20 2 22 23 2 25 26 27 28 29 30 5 55 56 57 58 59 60 6 62 63 500 3 32 33

More information

No: En Revision Parts List. Bravo

No: En Revision Parts List.   Bravo No: 899370 En Revision.0 200 05 Parts List Bravo 800 852.020 www.grindex.com Parts List Bravo 800 852.020 Overview Table of Contents This publication contains the following topics: Topic Preface... 4

More information

Flygt 3153, 50Hz. Technical Specification

Flygt 3153, 50Hz. Technical Specification Flygt 3153, 5Hz Technical Specification Table of Contents Table of Contents F-pump, Standard Motor... Product description... Motor rating and performance curves...4 F-pump, Premium Efficiency Motor (IE3)...

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning

More information

MZ, MA. Liquid ring pumps. 3 Design. 1 Fields of application. 4 Designation. 5 Materials. 2 Operating Data

MZ, MA. Liquid ring pumps. 3 Design. 1 Fields of application. 4 Designation. 5 Materials. 2 Operating Data Type series booklet CTI-1700/00 [12-2008] MZ, MA Liquid ring pumps 1 Fields of application Multi-stage, horizontal liquid ring pumps, with self-priming capacity. MZ and MA pumps are used for pumping of

More information

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 204 GAMMA 205 CURVE SPECIFICATIONS 206 PERFORMANCE CURVE 1X 207 PERFORMANCE CURVE 2X 208 PERFORMANCE CURVE 3X 53.7 209 PERFORMANCE CURVE

More information

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page - SPECIFICATIONS 0 SELECTION CHART 1 TYPE KEY 3 PERFORMANCE CURVE SPECIFICATIONS 4 PERFORMANCE CURVE 32-125 5 PERFORMANCE CURVE 32-6 PERFORMANCE CURVE 32-0 7 PERFORMANCE CURVE 40-125 8 PERFORMANCE

More information

Selection Chart Project: Model: Chk d: Date: C C V V V A CAPACITY

Selection Chart Project: Model: Chk d: Date: C C V V V A CAPACITY Selection Chart Project: Model: Chk d: Date: 45 (Ft) (m) 15.0 HZ (Synchronous Speed - 1800 RPM) 35 C2905-7 25.0 8.0 C1125-17 C15-1170 C2185-885 7.0 TOTAL HEAD 15 6.0 5.0 C1455-1170 V0494-1170 V0554-1170

More information

Level limit switch Series RF 3000 Selection list

Level limit switch Series RF 3000 Selection list Table of content Page Overview P2 Applications P4 ------------------------------------------------------------------------------------------------------------- RF 3100 Standard version P6 -------------------------------------------------------------------------------------------------------------

More information

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page SPECIFICATIONS 0 SELECTION CHART 1 TYPE KEY 3 PERFORMANCE CURVE SPECIFICATIONS 4 MEI INDEX SPECIFICATIONS 5 PERFORMANCE CURVE 32 6 PERFORMANCE CURVE 32 7 PERFORMANCE CURVE 320 8 PERFORMANCE

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control

More information

Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART BEST ONE 202 PERFORMANCE CHART BEST ONE VOX 203

Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART BEST ONE 202 PERFORMANCE CHART BEST ONE VOX 203 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART 202 PERFORMANCE CHART VOX 203 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 DIAGRAM AND ELECTRIC CONNECTIONS 302 DIAGRAM

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual 3126.290 Installation, Operation, and Maintenance Manual Table of Contents Table of Contents Introduction and Safety...3 Introduction...3 Safety...3 Safety terminology and symbols...3 Environmental safety...4

More information

INVCP, INVCN. Vertical pumps for tanks. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data

INVCP, INVCN. Vertical pumps for tanks. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data Type series booklet CTI-0300/03 [05-2012] INVCP, INVCN Vertical pumps for tanks 1. Fields of Application INVCP pumps are used for organic and inorganic liquids in water services and different industries.

More information

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 204 GAMMA 205 CURVE SPECIFICATIONS 206 PERFORMANCE CURVE 1X 207 PERFORMANCE CURVE 2X 208 PERFORMANCE CURVE 3X 53.7 209 PERFORMANCE CURVE

More information

YFC. Limit switch. Ex d. 24 operating head types

YFC. Limit switch. Ex d. 24 operating head types Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735

More information

DRS. EBARA PUMPS EUROPE S.p.A. SUBMERSIBLE PUMPS

DRS. EBARA PUMPS EUROPE S.p.A. SUBMERSIBLE PUMPS CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATION 202 PERFORMANCE CURVE /A40-115-1.1M, /A40-140-1.1M, /A40-136-1.1M, /A40-150-1.8M 203 PERFORMANCE CURVE /A40-136-1.4,

More information

DUMPER. Data Book 50 Hz

DUMPER. Data Book 50 Hz Data Book 50 Hz CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 CURVE SPECIFICATIONS 203 1X 51-S 204 1X 51.5-S 205 2X 51.5-S 206 2X 52.2-S 207 2X 53-S 208 3X

More information

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page SPECIFICATIONS 0 PERFORMANCE RANGE and SELECTION CHART 1 TYPE KEY 3 PERFORMANCE CURVE SPECIFICATIONS 4 MEI INDEX SPECIFICATIONS 5 PERFORMANCE CURVE 32 6 PERFORMANCE CURVE 32 7 PERFORMANCE

More information

DUMPER. Data Book 50 Hz

DUMPER. Data Book 50 Hz Data Book 50 Hz CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 CURVE SPECIFICATIONS 203 1X 51-S 204 1X 51.5-S 205 2X 51.5-S 206 2X 52.2-S 207 2X 53-S 208 3X

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact

More information

DUMPER. Data Book 50 Hz

DUMPER. Data Book 50 Hz Data Book 50 Hz CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 GAMMA 203 CURVE SPECIFICATIONS 204 1X 51-S 205 1X 51.5-S 206 2X 51.5-S 207 2X 52.2-S 208 2X 53-S 209 3X 53.7-S 210 3X

More information

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 14/03/2017

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 14/03/2017 Position Qty. Description 1 CR 32-3-2 A-F-A-E-HQQE Phone: 8 61 Date: 1/3/217 Product No.: 961221 Note! Product picture may differ from actual product Liquid: Pumped liquid: Water Liquid temperature range:

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked in position 0 and 1 > Clear

More information

Company name: GRUNDFOS (Singapore) Pte. Ltd. Created by: Angie Ang Phone: Date: 23/03/2017

Company name: GRUNDFOS (Singapore) Pte. Ltd. Created by: Angie Ang Phone: Date: 23/03/2017 Position Qty. Description 1 CR 15-7 A-F-A-E-HQQE Date: 3/3/17 Product No.: On request Note! Product picture may differ from actual product Liquid: Pumped liquid: Water Liquid temperature range: -.. 1 C

More information

BEV. Deep well vertical pumps. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data

BEV. Deep well vertical pumps. 3. Design. 1. Fields of Application. 4. Designation. 2. Operating Data Type series booklet CTI-2000/00 [09-2010] BEV Deep well vertical pumps 1. Fields of Application BEV are vertical multistage centrifugal pumps designed for deep well, ditches and tanks to pump clean liquids

More information

SE M.C.N.51D

SE M.C.N.51D GRUNDFOS DATA BOOKLET SE1.110.200.200.4.52M.C.N.51D Grundfos pump 98179813 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/98179813/se1-110-200-200-4-52m-c-n-51d.html

More information

KRS-819. parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet. Tsurumi Europe GmbH

KRS-819. parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet. Tsurumi Europe GmbH KRS-89 parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429 Heltorfer

More information

Continuous level measuring system NB 4000 Selection list

Continuous level measuring system NB 4000 Selection list Table of contents Page Overview P2 Specification / application P3 P4 Options / Accessories P6 Dimensions / materials P7 Spare parts P9 Electrical installation P11 Subject to change. All dimensions in mm

More information

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked

More information

VERTICAL IN-LINE PUMP

VERTICAL IN-LINE PUMP VERTICAL IN-LINE PUMP TECHNICAL FEATURES ELINE: Vertical centrifugal pumps, single impeller, volute casing, non-self priming pump, in-line executive, with mechanical seal. Hydraulically designed in line

More information

- CONTENTS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO

- CONTENTS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART 40 202 PERFORMANCE CHART 80 203 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL VIEW 301 MECHANICAL SEAL 302 DIAGRAM

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 CONSTRUCTIONS 301 CONSTRUCTIONS 302 MECHANICAL SEAL 303 COUNTERFLANGE 304

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 CONSTRUCTIONS 301 CONSTRUCTIONS 302 MECHANICAL SEAL 303 COUNTERFLANGE 304 CONTENTS Page - SPECIFICATIONS 200 PUMP SPECIFICATION 200 TYPE KEY 201 SELECTION CHART 202 SELECTION CHART 203 PERFORMANCE CURVE 3 ( 3-4-5-6 impellers ) 204 PERFORMANCE CURVE 3 ( 7-8-9 impellers ) 205

More information

Xylem Water Solutions AB (the Company) was previously named ITT Water & Wastewater AB. The name change took place in November 2011.

Xylem Water Solutions AB (the Company) was previously named ITT Water & Wastewater AB. The name change took place in November 2011. Xylem Water Solutions AB (the Company) was previously named ITT Water & Wastewater AB. The name change took place in November 2011. This is document is (i) a document that relates to a product of the Company

More information

- CONTENTS SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 2CDX PERFORMANCE CHART 2CDX PERFORMANCE CHART 2CDX

- CONTENTS SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 2CDX PERFORMANCE CHART 2CDX PERFORMANCE CHART 2CDX CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 120 203 PERFORMANCE CHART 200 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL

More information

ITT FLYGT ORIGINAL O-RING/INTERMEDIATE SERVICE KITS

ITT FLYGT ORIGINAL O-RING/INTERMEDIATE SERVICE KITS ITT FLYGT ORIGINAL O-RING/INTERMEDIATE SERVICE KITS O-RING KITS / INTERMEDIATE SERVICE KITS Quality products deserve genuine spare parts. ITT Flygt pumps and mixers work best with genuine ITT Flygt spare

More information

EN. 850 Filtrate Pumps. Technical Specification Pages

EN. 850 Filtrate Pumps. Technical Specification Pages 850 17.01.EN 850 Filtrate Pumps Technical Specification Pages 850 Series Filtrate Pump 850 17.01.EN This page left intentionally blank. 1.0 Overview. The 850 is Carver s filtrate pump line designed for

More information

DP A.2.50B. Grundfos pump GRUNDFOS DATA BOOKLET

DP A.2.50B. Grundfos pump GRUNDFOS DATA BOOKLET GRUNDFOS DATA BOOKLET DP10.65.26.A.2.50B Grundfos pump 96106544 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/dpfam/96106544/dp10-65-26-a-2-50b.html

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 203 PERFORMANCE CURVE 120 204 PERFORMANCE CURVE 200 205 - CONSTRUCTIONS 300 SECTIONAL VIEW

More information

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V)

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V) Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V) Pump curves Wilo-Drain TP 65 F - 50 Hz - 2900 rpm Unit Max. delivery head H max 9.5 m Max. volume flow Q max 36 m 3 /h Optimal delivery head H opt 6.0 m Optimum

More information

Position Switches Series 8070/2

Position Switches Series 8070/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

DML - DMLF. SUBMERSIBLE SEWAGE PUMPS (SINGLE-CHANNEL) in cast iron. Your Life, our Quality. Worldwide. 67 Wastewater APPLICATIONS TECHNICAL DETAILS

DML - DMLF. SUBMERSIBLE SEWAGE PUMPS (SINGLE-CHANNEL) in cast iron. Your Life, our Quality. Worldwide. 67 Wastewater APPLICATIONS TECHNICAL DETAILS APPLICATIONS TECHNICAL DETAILS TECHNICAL DATA 40 mm (DMLF) DN50, DN55, DN65 (DMLF) MATERIALS ACCESSORIES (ON REQUEST) PUMP IDENTIFICATION CODE 80 DML DMLF 5 2,2 50 HZ 2,2 3,7 5,5 7,5 11 15 22 MODEL OUTPUT

More information

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C Series CMIT in inline design Series CMAT with axial inlet ATEX 0 a Series CMAT Series

More information

Spare parts list ( ) Spare parts list B60 W Bp UL

Spare parts list ( ) Spare parts list B60 W Bp UL Spare parts list (5.971-886.0) Spare parts list B60 W Bp UL 14.12.2012 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list B60 W Bp UL (5.971-886.0)... 6 10 Tank (0.166-284.0)...

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

Features. Suitable for use in SIL 2 applications. Available in LP low power version with less than 1.65 A current consumption. General application

Features. Suitable for use in SIL 2 applications. Available in LP low power version with less than 1.65 A current consumption. General application The ICON 2000 v4 series are electronically-configurable quarter and multi-turn actuators with advanced operation, control, setting and maintenance characteristics Features General application The ICON

More information

DM 06 MAGNETIC DRIVE CENTRIFUGAL PUMPS

DM 06 MAGNETIC DRIVE CENTRIFUGAL PUMPS DM 6 Product of Italian origin Available in PP-PVDF Below head use No welded seams Max. flow rate from 7 m 3 /h Max head 8, m Extremely easy maintenance Low cost of spare parts No fluid leaks Viscosity

More information

- SPECIFICATIONS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART MULTIGO PERFORMANCE CHART MULTIGO

- SPECIFICATIONS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART MULTIGO PERFORMANCE CHART MULTIGO CONTENTS Page - CONTENTS CONTENTS 100 - SPECIFICATIONS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART 40 202 PERFORMANCE CHART 80 203 - CONSTRUCTIONS CONSTRUCTIONS 300 CONSTRUCTIONS 301 CONSTRUCTIONS

More information

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 201 CURVE SPECIFICATIONS 202 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 201 CURVE SPECIFICATIONS 202 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 201 CURVE SPECIFICATIONS 202 PERFORMANCE CHART 40 203 PERFORMANCE CHART 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL VIEW 301

More information

SL B. Grundfos pump GRUNDFOS DATA BOOKLET

SL B. Grundfos pump GRUNDFOS DATA BOOKLET GRUNDFOS DATA BOOKLET SL1.50.65.09.2.50B Grundfos pump 96106566 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1000/96106566/sl1-50-65-09-2-50b.html

More information

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet KTZ4-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Data Sheet KTZ4-5 Total Head m Efficiency % Output kw C.W.L. C.W.L. =

More information

NP 3153 MT 3~ 430 Te chnical specification

NP 3153 MT 3~ 430 Te chnical specification Te chnical specification 29. 2. 27. 2. 25. 2. 23. 22. 21.. 19. 1. 17. 1. 15. 1. 13.. 11.. 9.. 7.. 5. -. 3. 2. 1.. Water, pure Note: Picture might not correspond to the current configuration. General Patented

More information

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC ... 3... 4 3000 rpm 50 Hz / 3600 rpm 60 Hz... 4... 5... 7 Modular pump / motor systems... 7 Materials...........................................................

More information

RWCP, RWCN. Vertical pumps for tanks for loaded liquids. 1. Fields of Application. 3. Design. 4. Designation. 2. Operating Data

RWCP, RWCN. Vertical pumps for tanks for loaded liquids. 1. Fields of Application. 3. Design. 4. Designation. 2. Operating Data Type series booklet CTI-4900/01 [04-2012] RWCP, RWCN Vertical pumps for tanks for loaded liquids 1. Fields of Application RWCP and RWCN are vertical, centrifugal pumps designed for wells, ditches and tanks.

More information

LH311W-50. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

LH311W-50. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet LH3W-50 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 4047 Düsseldorf Germany Tel.: +49--479373 Fax: +49--47949

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 FITTINGS 305

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 FITTINGS 305 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART TABLE 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 3 ( 3-4-5-6 IMPELLERS ) 205 PERFORMANCE CURVE 3 ( 7-8-9 IMPELLERS

More information

ARBO. Pompen en Filters b.v.

ARBO. Pompen en Filters b.v. ARBO Pompen en Filters b.v. Product group 1.1 Chemical pumps SealPro Applications For all transport or circulation duties of corrosive liquids, even high viscosity, with maximum efficiency. This series

More information

Explosion and flame-proof single phase electric motors

Explosion and flame-proof single phase electric motors Explosion and flame-proof single phase electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 112 Single phase Voltage 230 50Hz Voltage 265 60Hz Types of mounting

More information

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4 Table of contents Page Specifications 2 Applications 4 ------------------------------------------------------------------------------------------------------------ CN 4020 5 Short extension length ------------------------------------------------------------------------------------------------------------

More information

KRS2-80. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

KRS2-80. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429

More information

Explosion and flame-proof cast iron electric motors

Explosion and flame-proof cast iron electric motors Explosion and flame-proof cast iron electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 160 3 phases Voltage 230/400 V 50Hz Voltage 265/460V 60Hz Types of mounting

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEALS 303 DIAGRAM AND ELECTRIC CONNECTIONS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEALS 303 DIAGRAM AND ELECTRIC CONNECTIONS 304 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 PERFORMANCE CHART A (up to 0.6 kw) 203 PERFORMANCE CHART A (from 0.75 kw up to 1.1 kw) 204 PERFORMANCE CHART A (1.3 kw) 205 PERFORMANCE

More information

Continuous level measuring system NB 3000 Selection list

Continuous level measuring system NB 3000 Selection list Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

LH parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet. Tsurumi Europe GmbH

LH parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet. Tsurumi Europe GmbH parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str. 6 40472 Düsseldorf Germany Control No. ILH-2-- 09.2.998 ITEM CODE No. DESCRIPTION

More information

Level limit switch Series RN 3000 / 6000 Selection list. Overview. Specifications. Applications

Level limit switch Series RN 3000 / 6000 Selection list. Overview. Specifications. Applications Table of contents Page Overview Specifications Applications P2 P4 P6 --------------------------------------------------------------------------------------------------------- RN..001 Short extension length

More information

Company name: Created by: Phone:

Company name: Created by: Phone: Qty. Description 1 CRE 1-5 A-FJ-A-E-HQQE Date: /3/17 Product No.: On request Note! Product picture may differ from actual product The pump is fitted with a 3-phase, fan-cooled asynchronous motor. The motor

More information

Technical Data BEST 2~5. Stainless Steel Submersible Sump Pumps EBARA PUMPS AUSTRALIA PTY. LTD. Best 2-5_Techdata_SS_V10

Technical Data BEST 2~5. Stainless Steel Submersible Sump Pumps EBARA PUMPS AUSTRALIA PTY. LTD. Best 2-5_Techdata_SS_V10 Technical Data BEST 2~5 Stainless Steel Submersible Sump Pumps EBARA PUMPS AUSTRALIA PTY. LTD. Best 2-5_Techdata_SS_ CONTENTS -SPECIFICATIONS Page Features & Applications 100 Exploded View 101 Pump & Motor

More information

SUBMERSIBLE PUMPS WITH SEMI-OPEN IMPELLER FOR CLEAN WATER AND RAINWATER in cast iron

SUBMERSIBLE PUMPS WITH SEMI-OPEN IMPELLER FOR CLEAN WATER AND RAINWATER in cast iron Submersible pumps with semi-open impeller for clean water and rainwater. APPLICATIONS Purification tank drainage Rain and spring water drainage Water supply TECHNICAL DETAILS Efficient semi-open impeller

More information

KTV2-22. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

KTV2-22. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 THERMAL INSULATION 301 MECHANICAL SEAL 302 BEARINGS DIMENSIONS and WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 THERMAL INSULATION 301 MECHANICAL SEAL 302 BEARINGS DIMENSIONS and WEIGHT 400 PUMP 400 PACKING 401 CONTENTS 1 Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY amd CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 203 PERFORMANCE CURVE 120 204 PERFORMANCE CURVE 200 205 - CONSTRUCTIONS

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

Position Qty. Description Single Price

Position Qty. Description Single Price Position Qty. Description Single Price 1 SEG.4.26.2.5B On request Product No.: 9675913 Note! Product picture may differ from actual product Grundfos SEG pumps are submersible pumps with horizontal discharge

More information

LH data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

LH data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Data Sheet o 50 mm JIS0K 448 mm 80 mm 530 mm Total Head m 027 mm Efficiency %

More information

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet KTZ35.5-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429

More information

Materials: Parts of the pump in contact with the liquid are manufactured from the following standard

Materials: Parts of the pump in contact with the liquid are manufactured from the following standard Plastic Centrifugal Pump For Chemical Process DIN EN 22858 (ISO 2858)Standard DESCRIPTION pumps are manufactured to DIN EN 22858 (ISO 2858) standards in respect of design, performance and dimensions. They

More information

Spring loaded resistance thermometer

Spring loaded resistance thermometer Spring loaded resistance thermometer THERMOWELL & REPLACEABLE INSERT C200-201-204-205-260-262 CONFIGURATIONS Ex ia RTD Product series PT100RI/WI C200 C201 C204 C205 C260 C262 2 Features assembly The industrial

More information

Floodlight Series 6121

Floodlight Series 6121 www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options

More information

MULTIGO. EBARA Pumps Europe S.p.A. CENTRIFUGAL PUMPS. Page

MULTIGO. EBARA Pumps Europe S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS 1 Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVES SPECIFICATIONS 202 PERFORMANCE CURVES 40 203 PERFORMANCE CURVES 80 204 - CONSTRUCTIONS SECTIONAL VIEW

More information

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECHNICAL DATA 500

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECHNICAL DATA 500 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE BEST 2 203 PERFORMANCE CURVE BEST 3 203 PERFORMANCE CURVE BEST 4 203 PERFORMANCE CURVE BEST

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 QUANTITY FOR MODEL 303 BEARINGS 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 QUANTITY FOR MODEL 303 BEARINGS 303 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATION 202 PERFORMANCE CURVE 40/86 203 PERFORMANCE CURVE 40/106 204 PERFORMANCE CURVE 40/126 205 PERFORMANCE CURVE 40/156

More information

Engineers Without Borders

Engineers Without Borders Engineers Without Borders Proposal No: JI12-02-07 04 Item No: ITEM 001 February 7, 2012 Attn: Adam MODEL:VIT-CATM Size:7CHC 10 Stage(s) QTY:1 Operating conditions SERVICE LIQUID LIQUID TYPE CAPACITY RATED

More information

KG(X)3. Grinder Pumps. 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Total Head (FT) Capacity (GPM)

KG(X)3. Grinder Pumps. 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Total Head (FT) Capacity (GPM) Grinder Pumps 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) The KEEN PUMP series centrifugal grinder pumps easily handle residential, commercial or industrial sanitary waste,

More information

POSEIDON 5 > I. Part List US-English

POSEIDON 5 > I. Part List US-English Model: POSEIDON 5-21 POSEIDON 5-28 POSEIDON 5-31 POSEIDON 5-32 POSEIDON 5-43 POSEIDON 5-51 POSEIDON 5-54 POSEIDON 5-58 POSEIDON 5-62 POSEIDON 5-63 POSEIDON FAVORITE Part List US-English Table of Contents

More information