TECHNICAL GUIDE LISTED

Size: px
Start display at page:

Download "TECHNICAL GUIDE LISTED"

Transcription

1 E T I I I R P I T G TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: H*BC-F018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH)H*BC- (T,W)036 THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at for the most up-to-date technical information. Additional rating information can be found at U R A C T MA N U F R C E UN I R T I C ER T A R I A RY F F I E D E Q U I C A T T S A T ON O T M E N S A R I AI E CT N D A R R - C D AS ONDI ON S 2 O I C 1 0 OM P NI N G OF L Y N I W IT H Rev. C (0505) DESCRIPTION The 12 SEER Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be custom-matched with one of UPG s complete line of evaporator sections, each designed to serve a specific function. Matching Air Handlers are available for upflow, downflow or horizontal applications to provide a complete system. Electric Heaters are available if required. Add-On coils are available for use with upflow, downflow or horizontal furnaces and air handlers. WARRANTY Single Phase Units: 5-year limited parts warranty. 10-year limited compressor warranty. Three Phase Units: 1-year limited parts warranty. 5-year limited compressor warranty. FEATURES QUALITY CONDENSER COILS - The coil is constructed of enhanced copper tube and aluminum fins. COIL PROTECTION - Coils are protected from damage by a polymer mesh applied between the coil face, and a PVC coated steel coil guard. PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor. DURABLE FINISH - The cabinet is made of pre-painted steel. The pre-treated galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and matted textured champagne finish insure less fading when exposed to sunlight. LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. Discharge line heat exchanger knockouts are provided, if required. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof. TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. LOW MAINTENANCE - Long life permanently lubricated motor-bearings need no annual servicing. EASY SERVICE ACCESS - Fully exposed refrigerant connections, a single panel covering the electrical controls and the molex plug in the control box connecting the condenser fan, make for easy servicing of the unit. SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging. U.L. and C.U.L. listed - approved for outdoor application. Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

2 Physical and Electrical Data - 1 Phase MODEL HBBC-F018S HBBC-F024S HBBC-F030S HBBC-F036S HBBC-F042S HBBC-F048S HDBC-F060S Unit Supply Voltage 208/ Normal Voltage Range 187 to 252 Minimum Circuit Ampacity Max. Overcurrent Device Amps Compressor Type 3 Recip Inertia Recip Recip Scroll B Recip Scroll B Rated Load Compressor Amps Locked Rotor Crankcase Heater No No No Yes No No No Fan Motor Amps Rated Load Fan Diameter Inches Fan Motor Rated HP 1/12 1/12 1/15 1/4 1/4 1/4 1/4 Nominal RPM 1,100 1, Nominal CFM 2,000 2,000 2,300 3,300 3,300 3,300 3,450 Face Area Sq. Ft Coil Rows Deep Fin / Inches Liquid Line OD 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line OD 3/4 3/4 3/4 3/4 7/8 7/8 1-1/8 Unit Charge (Lbs. - Oz.) Charge Per Foot, Oz Operating Weight Lbs PHYSICAL AND ELECTRICAL DATA - 3 Phase MODEL HABC-T036S HABC-T048S HABC-T060S HABC-W036S HABC-W048S HABC-W060S Unit Supply Voltage 208/ Normal Voltage Range to to 504 Minimum Circuit Ampacity Max. Overcurrent Device Amps Compressor Type Inertia Inertia Scroll Inertia Inertia Scroll Rated Load Compressor Amps Locked Rotor Crankcase Heater No No No No No No Fan Motor Amps Rated Load Fan Diameter Inches Fan Motor Rated HP 1/4 1/4 1/4 1/4 1/4 1/4 Nominal RPM Nominal CFM 3,300 3,300 3,400 3,300 3,300 3,400 Face Area Sq. Ft Coil Rows Deep Fin / Inches Liquid Line OD 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line OD 3/4 7/8 1-1/8 3/4 7/8 1-1/8 Unit Charge (Lbs. - Oz.) Charge Per Foot, Oz Operating Weight Lbs Rated in accordance with ARI Standard 110, utilization range A. 2. Dual element fuses or HACR circuit breaker. 3. All scrolls listed with a superscript B are Bristol scrolls. All scrolls listed with a superscript C are Copeland scrolls. 4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. 2 Unitary Products Group

3 Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase Outdoor Unit HBBC-F018S HBBC-F024S HBBC-F030S HBBC-F036S HBBC-F042S HBBC-F048S HCBC-F060S Unit Orifice (s) Factory R-22 Charge, lbs-oz Indoor Coil 5 Coil Orifice 4 Orifice or TXV Kit 2 - Additional Charge, Oz. 3 G2FD024(S,H)14, G2FD030(S,H) G2FD035(S,H) G2FD036(S,H) G2FD036(S,H) G2FD042(S,H) G2FD046(S,H) G2FD048(S,H)21, G2FD060(S,H) G2FD061H G1HA024H G1HA024H14(T) TXV G1HA036H G1HA036H14(T) TXV G1HA036H G1HA036H17(T) TXV G1HA048H G1HA048H21(T) TXV G1HA060H G1HA060H24(T) TXV G1HD G1HD G1HD G1HD G1FA/G1UA024S14,17(T) G1FA/G1UA030S14(T) G1FA/G1UA036S14(T) G1FA/G1UA036S17,21(T) G1FA/G1UA048S17(T) G1FA/G1UA048S21(T) G1FA/G1UA060S21,24(T) G1NA030S17K G1NA030S21M See notes on Page 4. Unitary Products Group 3

4 Additional R-22 Charge / Orifice Size for Various Matched Systems (Continued)- 1 Phase Outdoor Unit HBBC-F018S HBBC-F024S HBBC-F030S HBBC-F036S HBBC-F042S HBBC-F048S HCBC-F060S Unit Orifice (s) Factory R-22 Charge, lbs-oz Indoor Coil 5 Coil Orifice 4 Orifice or TXV Kit 2 - Additional Charge, Oz. 3 G1NA036S17L 63 G1NA048S21D 78 G1NA048S24P 63 G1NA060S24T 78 G1NF024SOF 63 G1NF036SOF 67 G1NF048SOF 78 G1NF060SOF 87 F(2,3)RP024N,H06(T) 61 F(2,3)RP030N06(T) 65 F(2,3)RP036N06(T) 75 F(2,3)RP042N06(T) 78 F(2,3)FP048N06(T) 84 F(2,3)FP060N06(T) 90 F(2,3)FV060N06(T) 90 FOOTNOTES: PROCEDURES: These orifices are factory mounted in the flow control device of each indoor coil and must be removed for TXV installation. 2. A TXV kit must be used with these coils to obtain system performance. (701,702,703 indicates 1TV07...series). 3. Systems matched with furnaces or air handlers not equipped with blower-off delays, may require blower Time Delay Kit #6918A These orifices are factory mounted in the flow control device of each indoor coil. A TXV is factory mounted if the model number has a (T) suffix. 5. This TXV is factory mounted in indoor coils, if the model number has a (T) suffix. 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and for 15 feet of interconnecting line tubing. 2. Verify the orifice size and additional charge required for specific evaporator coil in the system using the above table. 3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set. 5. If the orifice in the evaporator was changed, verify the evaporator nameplate has been marked with the correct orifice size. 4 Unitary Products Group

5 Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase Outdoor Unit HABC-T,W036S HABC-T,W048S HABC-T,W060S Unit Orifice (s) 1 Factory R-22 Charge, lbs-oz Indoor Coil Coil Orifice TVX Kit 2 = Additional Charge, Oz 3 G2FD035(S,H) G2FD036(S,H)17, G2FD042(S,H) G2FD046(S,H) G2FD048(S,H)21, G2FD060(S,H) G2FD061H G1FA/G1UA036S G1FA/G1UA036S17, G1FA/G1UA048S G1FA/G1UA048S G1FA/G1UA060S21, G1NA036S17L G1NA048S21D G1NA048S24P G1NA060S24T G1NF036SOF G1NF048SOF G1NF060SOF G1HD G1HD G1HD FOOTNOTES: 1. These orifices are factory mounted in the flow control device of each indoor coil and must be removed for TXV installation. 2. A TXV kit must be used with these coils to obtain system performance. (701,702,703 indicates 1TV07...series). 3. Systems matched with furnaces or air handlers not equipped with blower-off delays, may require blower Time Delay Kit #6918A5011. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and for 15 feet of interconnecting line tubing. 2. Verify the orifice size and additional charge required for specific evaporator coil in the system using the above table. 3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set. 5. If the orifice in the evaporator was changed, verify the evaporator nameplate has been marked with the correct orifice size. Unitary Products Group 5

6 COOLING CAPACITY - With Air Handler Coils AIR HANDLER UNIT MODEL COIL 1 COOLING MODEL ELECTRIC 2 RATED NET MBH W MODEL HEAT KW CFM TOTAL SENS. 1 PH 12 SEER AC WITH N1AH / G2FD SEER W/O TXV 4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC. models. All ratings remain the same. 5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard. - = Not applicable. SEER WITH TXV 3 HBBC-F018S N1AHB0806 2,5,8,10 17 G2FD024(S,H) HBBC-F024S N1AHB0806 2,5,8,10 17 G2FD024(S,H) N1AHB0806 2,5,8,10 17 G2FD030(S,H) HBBC-F030S N1AHB1206 2,5,8,10 17 G2FD030(S,H) N1AHB1206 2,5,8,10 17 G2FD036(S,H) HBBC-F036S N1AHB1206 5,8,10,15,19 17 G2FD036(S,H) N1AHB1206 5,8,10,15,19 17 G2FD046(S,H) HBBC-F042S N1AHC1606 5,8,10,15,20 21 G2FD042(S,H) N1AHC1606 5,8,10,15,20 21 G2FD048(S,H) N1AHC1606 5,8,10,15,20 21 G2FD048(S,H) HBBC-F048S N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H) N1AHD2006 8,10,15,20,25,30 24 G2FD061H HCBC-F060S N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H) N1AHD2006 8,10,15,20,25,30 24 G2FD061H PH 12 SEER AC WITH N1AH / G2FD N1AHB1246 5,8,10,15,18 17 G2FD036(S,H) HABC-(T,W)036S N1AHB1246 5,8,10,15,18 17 G2FD046(S,H) N1AHC1646 5,8,10,15,18 21 G2FD048(S,H) HABC-(T,W)048S N1AHD2046 8,10,15,20,25,30 24 G2FD060(S,H) N1AHD2046 8,10,15,20,25,30 24 G2FD061H HABC-(T,W)060S N1AHD2046 8,10,15,20,25,30 24 G2FD060(S,H)24(T) N1AHD2046 8,10,15,20,25,30 24 G2FD061H PH 12 SEER / N1VS - VARIABLE SPEED HBBC-F018S N1VSB12 10,15,18 17 G2FD024(S,H) HBBC-F024S N1VSB12 10,15,18 17 G2FD024(S,H) N1VSB12 10,15,18 17 G2FD036(S,H) N1VSB12 10,15,18 17 G2FD036(S,H) HBBC-F030S N1VSB12 10,15,18 17 G2FD046(S,H) N1VSB12 10,15,18 17 G2FD046(S,H) N1VSB12 10,15,18 17 G2FD036(S,H) HBBC-F036S N1VSB12 10,15,18 17 G2FD046(S,H) N1VSC16 10,15,18 21 G2FD048(S,H) HBBC-F042S N1VSC16 10,15,18 21 G2FD048(S,H) N1VSC16 10,15,18 21 G2FD048(S,H) N1VSC16 10,15,18 21 G2FD048(S,H) HBBC-F048S N1VSD20 10,15,18,30 24 G2FD060(S,H) N1VSD20 10,15,18,30 24 G2FD061H HCBC-F060S N1VSD20 10,15,18,30 24 G2FD060(S,H) N1VSD20 10,15,18,30 24 G2FD061H PH 12 SEER AC / F2RP / RC / FC 4, 5 HBBC-F018S F2RC/F2FC024 5,8, F2RP/F2FP024 5,8, F2RC/F2FC024 5,8, HBBC-F024S F2RC/F2FC030 5,8,10, F2RP/F2FP024 5,8, F2RP/F2FP030 5,8,10, F2RC/F2FC030 5,8,10, HBBC-F030S F2RC/F2FC036 5,8,10, F2RP/F2FP030 5,8,10, F2RP/F2FP036 5,8,10,15, F2RC/F2FC036 5,8,10, HBBC-F036S F2RP/F2FP036 5,8,10,15, F2RP/F2FP042 5,8,10, F2FP048 5,8,10,15,20, HBBC-F042S F2RP/F2FP042 5,8,10, F2FP048 5,8,10,15,20, F2FP048 5,8,10,15,20, HBBC-F048S F2FP060 5,8,10,15,20, F2FV060 8,10,15,20, HCBC-F060S F2FP060 5,8,10,15,20, F2FV060 8,10,15,20, Rated in accordance with DOE test procedures (Federal Register and ) and ARI Standards 210. Cooling MBH based on 80 F entering air temperature, 50% RH, and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTU s at a 95 F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2. Single phase units require single phase 2HK heaters. Three phase units require three phase 2HK heaters. 3. TXV = Thermal Expansion Valve kit required. Use 1TV700 series kit. 6 Unitary Products Group EER

7 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils FURNACE** COOLING UNIT MODEL COIL CFM RANGE NET MBH W MODEL RATED CFM SEER (Min.-max.) W/O TXV SEER + TXV 1 EER TOTAL SENS. HBBC-F018S HBBC-F024S HBBC-F030S For Notes See Page ,17 G1FA024S14, * G1HA024H * G1HA024H14T * G1HD * G1NA030S17K * G1NA030S21M * ,17 G1UA024S14, * ,17 G2FD024(S,H)14, * G2FD030(S,H) * G2FD035(S,H) * ,17 G1FA024S14, * G1FA030S * G1FA036S * ,21 G1FA036S17, * G1HA024H * G1HA024H14T * G1HA036H G1HD * G1HD * G1NA030S17K * G1NA030S21M * ,17 G1UA024S14, * G1UA030S * G1UA036S * ,21 G1UA036S17, * ,17 G2FD024(S,H)14, * G2FD030(S,H) * G2FD035(S,H) * G2FD036(S,H) * G1FA030S * G1FA036S * ,21 G1FA036S17, * G1FA048S * G1FA048S * G1HA036H * G1HA036H * G1HA036H * G1HA036H17T * G1HD * G1NA030S17K * G1NA030S21M * G1NA036S17L * G1UA030S * G1UA036S * ,21 G1UA036S17, * G1UA048S * G1UA048S * G2FD030(S,H) * G2FD035(S,H) * G2FD036(S,H) * G2FD036(S,H) * G2FD042(S,H) * G2FD046(S,H) * Unitary Products Group 7

8 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Continued) FURNACE** COOLING COIL UNIT MODEL CFM RANGE NET MBH W MODEL SEER RATED CFM (Min.-max.) W/O TXV SEER + TXV 1 EER TOTAL SENS. HBBC-F036S HABC-(T,W)036S HBBC-F042S For Notes See Page G1FA036S * ,21 G1FA036S17, * G1FA048S * G1FA048S * G1HA036H * G1HA036H * G1HA036H * G1HA036H17T * G1HA048H * G1HA048H21T G1HD * G1HD * G1NA036S17L * G1NA048S21D * G1UA036S * ,21 G1UA036S17, * G1UA048S * G1UA048S * G1NA048S21D * G2FD035(S,H) * G2FD036(S,H) * G2FD036(S,H) * G2FD042(S,H) * G2FD046(S,H) * ,24 G2FD048(S,H)21, * G1FA036S ,21 G1FA036S17, G1FA048S G1HD G1HD G1NA036S17L G1NA048S21D G1UA036S ,21 G1UA036S17, G1UA048S G2FD035(S,H) G2FD036(S,H) G2FD036(S,H) G2FD042(S,H) G2FD046(S,H) ,24 G2FD048(S,H)21, G1FA048S * G1FA048S ,24 G1FA060S21, G1HA048H * G1HA048H21T G1HD G1NA048S21D * G1UA048S * G1UA048S ,24 G1UA060S21, * G2FD042(S,H) * G2FD046(S,H) * ,24 G2FD048(S,H)21, Unitary Products Group

9 HBBC-F048S HABC-(T,W)048S HDBC-F060S HABC-(T,W)060S TXV = Use 1TV700 Series Kit. *Requires 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up Rev. C (0505) COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Continued) FURNACE** COOLING COIL UNIT MODEL CFM RANGE NET MBH W MODEL SEER RATED CFM (Min.-max.) W/O TXV SEER + TXV 1 EER TOTAL SENS. 17 G1FA048S * G1FA048S * ,24 G1FA060S21, * G1HA048H * G1HA048H21T * G1HA060H * G1HA060H24T * G1HD * G1HD * G1NA048S21D * G1UA048S * G1UA048S * ,24 G1UA060S21, * G2FD046(S,H) * ,24 G2FD048(S,H)21, * G2FD060(S,H) * G2FD061H * G1FA048S G1FA048S ,24 G1FA060S21, G1HD G1HD G1NA048S21D G1UA048S G1UA048S ,24 G1UA060S21, G2FD046(S,H) ,24 G2FD048(S,H)21, G2FD060(S,H) G2FD061H G1FA060S21(T) G1HD G1NA060S24T G1UA060S21(T) G2FD060(S,H)24(T) G2FD061H G1HA60S24(T) ,24 G1FA060S21, G1HA060H24T * G1HD G1NA060S24T * ,24 G1UA060S21, G2FD060(S,H) G2FD061H Unitary Products Group 9

10 COOLING CAPACITY - With Variable Speed Furnaces UNIT MODEL COOLING VARIABLE SPEED FURNACE MODEL COIL MODEL 1 W RATED NET MBH SEER SEER CFM TOTAL SENS. W/O TXV + TXV 2 EER 1 PH 12 SEER AC - VARIABLE SPEED 3 G8V***12UHA/(F,L)L8V***A12UH G1FA024S G8V***12UHA/(F,L)L8V***A12UH G2FD024(S,H) HBBC-F018S G9V***12DHB G2FD024(S,H) G9V***12UPB G1FA024S G9V***12UPB G2FD024(S,H) G8V***12UHA/(F,L)L8V***A12UH G1FA024S G8V***12UHA/(F,L)L8V***A12UH G2FD024(S,H) HBBC-F024S G9V***12DHB G2FD024(S,H) G9V***12UPB G1FA024S G9V***12UPB G2FD024(S,H) G8V***12UHA/(F,L)L8V***A12UH G1FA030S G8V***12UHA/(F,L)L8V***A12UH G2FD035(S,H) G8V***16UHB/(F,L)L8V***B16UH G1FA036S G8V***16UHB/(F,L)L8V***B16UH G2FD030(S,H) HBBC-F030S G9V***12DHB G2FD030(S,H) G9V***12UPB G1FA036S G9V***12UPB G2FD030(S,H) G9V***16UPC G1FA036S G9V***16UPC G2FD036(S,H) G8V***12UHA/(F,L)L8V***A12UH G1FA036S G8V***12UHA/(F,L)L8V***A12UH G2FD035(S,H) G8V***16UHB/(F,L)L8V***B16UH G1FA036S G8V***16UHB/(F,L)L8V***B16UH G2FD036(S,H) G8V***20UHC/(F,L)L8V***C20UH G1FA036S G8V***20UHC/(F,L)L8V***C20UH G2FD036(S,H) HBBC-F036S G9V***12DHB G2FD036(S,H) G9V***12UPB G1FA036S G9V***12UPB G2FD036(S,H) G9V***16UPC G1FA036S G9V***16UPC G2FD036(S,H) G9V***20UPC G1FA048S G9V***20UPC G2FD042(S,H) G9V***20UPD G2FD048(S,H) G8V***12UHA/(F,L)L8V***A12UH G1FA036S G8V***12UHA/(F,L)L8V***A12UH G2FD035(S,H) G8V***16UHB/(F,L)L8V***B16UH G1FA036S G8V***16UHB/(F,L)L8V***B16UH G2FD036(S,H) G8V***20UHC/(F,L)L8V***C20UH G1FA036S G8V***20UHC/(F,L)L8V***C20UH G2FD036(S,H) HABC-(T,W)036S G9V***12UPB G1FA036S G9V***12UPB G2FD036(S,H) G9V***16UPC G1FA036S G9V***16UPC G2FD036(S,H) G9V***20UPC G1FA048S G9V***20UPC G2FD042(S,H) G9V***20UPD G2FD048(S,H) G8V***16UHB/(F,L)L8V***B16UH G1FA048S G8V***20UHC/(F,L)L8V***C20UH G1FA048S HBBC-F042S G9V***20DHD G2FD048(S,H) G9V***16UPC G1FA048S G9V***20UPD G1FA060S G9V***20UPD G2FD048(S,H) For Notes See Page Unitary Products Group

11 COOLING CAPACITY - With Variable Speed Furnaces UNIT MODEL HBBC-F048S HABC-(T,W)048S HDBC-F060S HABC-(T,W)060S VARIABLE SPEED FURNACE MODEL COIL MODEL 1 W Rev. C (0505) TOTAL SENS. G8V***20UHC/(F,L)L8V***C20UH G1FA048S G8V***20UHC/(F,L)L8V***C20UH G2FD048(S,H) G9V***20DHD G2FD048(S,H) G9V***16UPC G1FA048S G9V***16UPC G2FD048(S,H) G9V***20UPC G1FA048S G9V***20UPC G2FD048(S,H) G9V***20UPD G1FA060S G9V***20UPD G2FD048(S,H) G9V***20UPD G2FD060(S,H) G8V***20UHC/(F,L)L8V***C20UH G1FA048S G8V***20UHC/(F,L)L8V***C20UH G2FD048(S,H) G9V***16UPC G1FA048S G9V***16UPC G2FD048(S,H) G9V***20UPC G1FA048S G9V***20UPC G2FD048(S,H) G9V***20UPD G1FA060S G9V***20UPD G2FD048(S,H) G9V***20UPD G2FD060(S,H) (G,L)8V***20UHD G1FA/G1UA060S21(T) (G,L)8V***20UHD G2FD060(S,H)24(T) (G,L)8V***20UHD G2FD061H G9V***20UPC G1FA/G1UA060S21(T) G9V***20UPC G2FD060(S,H)24(T) G9V***20UPC G2FD061H G9V***20UPD G1FA/G1UA060S24(T) G9V***20UPD G2FD060(S,H)24(T) G9V***20UPD G2FD061H G9V***20DHC G2FD060(S,H)24(T) G9V***20DHC G2FD061H G9V***20DHC G1HA60H24(T) G9V***20DHC G1HD G9V***20DHD G2FD060(S,H)24(T) G9V***20DHD G2FD061H G9V***20UHD G1HA60H24(T) G9V***20UHD G1HD (F,L)L8V***C20UH G1FA/G1UA060S21(T) (F,L)L8V***C20UH G2FD060(S,H)24(T) (F,L)L8V***C20UH G2FD061H G9V***20DHD G2FD060(S,H) G9V***20UPC G1FA060S G9V***20UPD G1FA060S G9V***20UPD G2FD060(S,H) G9V***20UPD G2FD061H G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2. TXV = Use 1TV700 Series Kit. 3. Variable speed furnaces have B.O.D (Blower on Delay) standard. RATED CFM COOLING NET MBH SEER W/O TXV SEER + TXV 2 EER Unitary Products Group 11

12 ACCESSORIES* All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. DIMENSIONS - 1 Phase Unit Model Dimensions (Inches) A 1 1. Including Fan Guard. * Expander fitting required for 1-1/8 line set. Refrigerant Connection Line Size B C Liquid Vapor / / / /8 * DIMENSIONS - 3 Phase Unit Model A Dimensions (Inches) Refrigerant Connection Line Size A 1 B C Liquid Vapor /8 3/ /8 7/ /8 1-1/8 * B C Refer to Price Manual for specific model numbers. Hard Start Kit - Provides increased starting torque for areas with low voltage. Compressor Blanket - Designed to further reduce the normal compressor operating sound. Refer to price pages for specific match-ups. Off Cycle Timer Delay - Provides a 5-minute off cycle to prevent rapid recycling of the compressor. Room Thermostats - A wide selection of compatible thermosets are available to provide optimum performance and features for any installation. 1 Heat Stage only, manual, mechanical thermostat. Add subbase for 1H/1C. 1H/1C, manual change-over electronic non-programmable thermostat. 1H/1C, auto/manual changeover, electronic programmable, deluxe 7-day, thermostat. 1H/1C, auto/manual changeover, electronic programmable. * For the most current accessory information, refer to the price book or consult factory. SOUND POWER RATINGS UNIT MODEL (dba)* * Rated in accordance with ARI Standards. 1. Including Fan Guard. * Reducer Required 12 Unitary Products Group

13 TYPICAL INSTALLATION 60 OVERHEAD CLEARANCE MINIMUM 18 SERVICE ACCESS CLEARANCE ON ONE SIDE WEATHERPROOF DISCONNECT SWITCH THERMOSTAT TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING NEC CLASS 2 WIRING 10 CLEARANCE COIL AREA TO INDOOR COIL NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF. SEAL OPENING(S) WITH PERMAGUM OR EQUIVALENT CONTROL ACCESS PANEL TYPICAL FIELD WIRING - 1 Phase Application ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 208/ VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2) C Y R G W POWER WIRING CONTROL WIRING FACTORY WIRING FURNACE OR AIR HANDLER TERMINAL BLOCK GND. LUG CONTACTOR TERMINALS COIL Y R G W * * TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT. CONDENSING UNIT ALL OUTDOOR WIRING MUST BE WEATHERPROOF. ROOM THERMOSTAT USE COPPER CONDUCTORS ONLY. TYPICAL FIELD WIRING - 3 Phase Application ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 208/ VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2) POWER WIRING CONTROL WIRING FACTORY WIRING FURNACE OR AIR HANDLER TERMINAL BLOCK GND. LUG CONTACTOR TERMINALS COIL * TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT. C Y R G W * Y R G W CONDENSING UNIT ROOM THERMOSTAT ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY. Unitary Products Group 13

14 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSING ENTERING AIR TEMPERATURE HBBC-F018S G1FA024S14,17 IDCFM ID DB ( F) ID WB ( F) T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW F2RC/F2FC F2RP/F2FP N1AHB0806 G2FD024(S,H)14, N1VSB12 G2FD024(S,H) G1HD G1NA030S17K G1NA030S21M G1UA024S14, G2FD024(S,H)14, G2FD030(S,H) G2FD035(S,H) Variable Speed Furnace Coil T.C. S.C. KW G8V***12UHA G1FA024S G8V***12UHA G2FD024(S,H) G9V***12DHB G2FD024(S,H) G9V***12UPB G1FA024S G9V***12UPB G2FD024(S,H) Unitary Products Group

15 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSING ENTERING AIR TEMPERATURE HBBC-F024S G1FA036S17,21 IDCFM ID DB ( F) ID WB ( F) T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW F2RP/F2FP F2RP/F2FP F2RC/F2FC F2RC/F2FC N1AHB0806 G2FD024(S,H) N1AHB0806 G2FD030(S,H) N1VSB12 G2FD024(S,H) N1VSB12 G2FD036(S,H) G1FA024S14, G1FA030S G1FA036S G1HD G1HD G1NA030S17K G1NA030S21M G1UA024S14, G1UA030S G1UA036S G1UA036S17, G2FD024(S,H)14, G2FD030(S,H) G2FD035(S,H) G2FD036(S,H) Variable Speed Furnace Coil T.C. S.C. KW G8V***12UHA G1FA024S G8V***12UHA G2FD024(S,H) G9V***12DHB G2FD024(S,H) G9V***12UPB G1FA024S G9V***12UPB G2FD024(S,H) Unitary Products Group 15

16 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSING ENTERING AIR TEMPERATURE HBBC-F030S G1FA036S17,21 IDCFM ID DB ( F) ID WB ( F) T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW F2RP/F2FP F2RP/F2FP F2RC/F2FC F2RC/F2FC N1AHB1206 G2FD030(S,H) N1AHB1206 G2FD036(S,H) N1VSB12 G2FD036(S,H) N1VSB12 G2FD046(S,H) G1FA030S G1FA036S G1FA048S G1FA048S G1HD G1NA036S17L G1NA030S17K G1NA030S21M G1UA030S G1UA036S G1UA036S17, G1UA048S G1UA048S G2FD030(S,H) G2FD035(S,H) G2FD036(S,H) G2FD036(S,H) G2FD042(S,H) G2FD046(S,H) Variable Speed Furnace Coil T.C. S.C. KW G8V***12UHA G1FA030S G8V***12UHA G2FD035(S,H) G8V***16UHB G1FA036S G8V***16UHB G2FD030(S,H) G9V***12DHB G2FD030(S,H) G9V***12UPB G1FA036S G9V***12UPB G2FD030(S,H) G9V***16UPC G1FA036S G9V***16UPC G2FD036(S,H) Unitary Products Group

17 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSING ENTERING AIR TEMPERATURE HBBC-F036S G1FA048S21 IDCFM ID DB ( F) ID WB ( F) T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW F2RC/F2FC F2RP/F2FP F2RP/F2FP F2FP N1VSB12 G2FD036(S,H) N1VSB12 G2FD046(S,H) N1VSC16 G2FD048(S,H) N1AHB1206 G2FD036(S,H) N1AHB1206 G2FD046(S,H) G1FA036S17, G1FA036S G1FA048S G1HD G1HD G1NA048S21D G1NA036S17L G1UA036S17, G1UA036S G1UA048S G1UA048S G2FD035(S,H) G2FD036(S,H) G2FD036(S,H) G2FD042(S,H) G2FD046(S,H) G2FD048(S,H)21, Variable Speed Furnace Coil T.C. S.C. KW G8V***12UHA G1FA036S G8V***12UHA G2FD035(S,H) G8V***16UHB G1FA036S G8V***16UHB G2FD036(S,H) G8V***20UHC G1FA036S G8V***20UHC G2FD036(S,H) G9V***12DHB G2FD036(S,H) G9V***12UPB G1FA036S G9V***12UPB G2FD036(S,H) G9V***16UPC G1FA036S G9V***16UPC G2FD036(S,H) G9V***20UPC G1FA048S G9V***20UPC G2FD042(S,H) G9V***20UPD G2FD048(S,H) Unitary Products Group 17

18 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSING ENTERING AIR TEMPERATURE HABC-(T,W)036S G1FA048S21 IDCFM ID DB ( F) ID WB ( F) T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHB1246 G2FD036(S,H) N1AHB1246 G2FD046(S,H) G1FA036S G1FA036S17, G2FD035(S,H) G2FD036(S,H) G2FD036(S,H) G2FD042(S,H) G2FD046(S,H) G2FD048(S,H)21, G1HD G1HD G1NA036S17L G1NA048S21D G1UA036S G1UA036S17, G1UA048S Variable Speed Furnace Coil T.C. S.C. KW G8V***12UHA G1FA036S G8V***12UHA G2FD035(S,H) G8V***16UHB G1FA036S G8V***16UHB G2FD036(S,H) G8V***20UHC G1FA036S G8V***20UHC G2FD036(S,H) G9V***12UPB G1FA036S G9V***12UPB G2FD036(S,H) G9V***16UPC G1FA036S G9V***16UPC G2FD036(S,H) G9V***20UPC G1FA048S G9V***20UPC G2FD042(S,H) G9V***20UPD G2FD048(S,H) Unitary Products Group

19 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSING ENTERING AIR TEMPERATURE HBBC-F042S G1FA048S21 IDCFM ID DB ( F) ID WB ( F) T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW F2RP/F2FP F2FP N1AHC1606 G2FD042(S,H) N1AHC1606 G2FD048(S,H) N1VSC16 G2FD048(S,H) G1FA048S G1FA060S21, G1HD G1NA048S21D G1UA048S G1UA048S G1UA060S21, G2FD042(S,H) G2FD046(S,H) G2FD048(S,H)21, Variable Speed Furnace Coil T.C. S.C. KW G8V***16UHB G1FA048S G8V***20UHC G1FA048S G9V***20DHD G2FD048(S,H) G9V***16UPC G1FA048S G9V***20UPD G1FA060S G9V***20UPD G2FD048(S,H) Unitary Products Group 19

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: AC018X12* THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH)

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: AC018X12* THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) E T I I I R P I T G TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: AC018X12* THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) LISTED ISO 9001 Certified Quality Management System CERTIFICATION APPLIES

More information

TECHNICAL GUIDE DESCRIPTION

TECHNICAL GUIDE DESCRIPTION TECHNICAL GUE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER S: BRCS018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) H*BA-(T,W)036 THRU 090 (3 THRU 7.5 NOMINAL TONS, 3 PH) S: 018-060 (1 PH & 3 PH) S: 076-090 (3 PH)

More information

TECHNICAL GUIDE LISTED

TECHNICAL GUIDE LISTED T I I I T G TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER MODELS: H*BA018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) H*BA036(25,46) THRU 090 (3 THRU 7.5 NOMINAL TONS, 3 PH) This product was manufactured

More information

LISTED TECHNICAL GUIDE STELLAR 2000 TM

LISTED TECHNICAL GUIDE STELLAR 2000 TM E T I I I R P I T I O I N G TECHNICAL GUIDE STELLAR 2000 TM SPLIT-SYSTEM AIR CONDITIONERS 10 SEER S: H*DB018 THRU 060 (1 THRU 5 NOMINAL TONS, 1 PH) H*DB036 THRU 076 (3 THRU 6-1/3 NOMINAL TONS, 3 PH) This

More information

TECHNICAL GUIDE LISTED

TECHNICAL GUIDE LISTED P G TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 10 SEER MODELS: HP018X10* THRU 060X10* (1.5 THRU 5 NOMINAL TONS) HP036X10* THRU 060X10* (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management

More information

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS) TECHNICAL GUIDE TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE S: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS) LISTED Due to continuous product improvement, specifications are subject

More information

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60 TECHNICAL GUIDE GUARDIAN SERIES DRY SHIP AIR CONDITIONER CONDENSING UNITS SHIPPED WITH NITROGEN CHARGE ONLY 13 SEER R-22 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: GCGD18 THRU 60 UARDIAN Due to continuous

More information

LISTED TECHNICAL GUIDE AFFINITY R-410A SPLIT-SYSTEM AIR CONDITIONERS UP TO 18 SEER MODELS: CZE024 THRU 060 (2 THRU 5 NOMINAL TONS)

LISTED TECHNICAL GUIDE AFFINITY R-410A SPLIT-SYSTEM AIR CONDITIONERS UP TO 18 SEER MODELS: CZE024 THRU 060 (2 THRU 5 NOMINAL TONS) E T I I I R P I T G 036-21592-002 Rev. A (1204) TECHNICAL GUIDE AFFINITY R-410A SPLIT-SYSTEM AIR CONDITIONERS UP TO 18 SEER MODELS: CZE024 THRU 060 (2 THRU 5 NOMINAL TONS) U R A C T MA N U F R C E UN I

More information

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 MODELS: GCGD12 THRU 60 (1 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 MODELS: GCGD12 THRU 60 (1 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 S: GCGD12 THRU 60 (1 THRU 5 NOMINAL TONS, 1 PHASE) LISTED Due to continuous product improvement, specifications are subject to change without

More information

SPLIT SYSTEM HEAT PUMPS. ERA Series 10 SEER Single and Three Phase TECHNICAL SPECIFICATIONS

SPLIT SYSTEM HEAT PUMPS. ERA Series 10 SEER Single and Three Phase TECHNICAL SPECIFICATIONS 515.16-TG1Y (499) TECHNICAL SPECIFICATIONS SPLIT SYSTEM HEAT PUMPS Models 018-060 1Ø 036, 048 3Ø ERA Series 10 SEER Single and Three Phase Models ERA 018 thru ERA090 Nominal Capacity: 18 thru 90 MBH Models

More information

TECHNICAL GUIDE 16 SEER 2-5 TON AIR CONDITIONING SPLIT-SYSTEM COOLING H4TS024 H4TS030 H4TS036 H4TS048 H4TS060 DESCRIPTION FEATURES MODELS:

TECHNICAL GUIDE 16 SEER 2-5 TON AIR CONDITIONING SPLIT-SYSTEM COOLING H4TS024 H4TS030 H4TS036 H4TS048 H4TS060 DESCRIPTION FEATURES MODELS: 036-21023-002 Rev A (5/00) TECHNICAL GUIDE 16 SEER 2-5 TON CONDITIONING SPLIT-SYSTEM COOLING DESCRIPTION The HTS Stealth series condensing units use Twin Single compressor technology to provide cooling

More information

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES P G 036-21342-002 Rev. C (0902) TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) U R MA N U F A CT R E C E CE R T I F R T I UN I TA RY A R I F I

More information

LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE MODELS: YCJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE MODELS: YCJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES DESCRIPTION 364834-YTG-H-0509 The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS TECHNICAL GUIDE RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RAC13J18 THRU 60 Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE MODELS: RHP14J18 THRU 60 RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: RHP14J18 THRU 60 RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES TECHNICAL GUIDE RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RHP14J18 THRU 60 Due to continuous product improvement, specifications are subject to change without

More information

LISTED TECHNICAL GUIDE HORIZONTAL DISCHARGE AIR CONDITIONERS 13 SEER R-410A MODELS: YCHD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE)

LISTED TECHNICAL GUIDE HORIZONTAL DISCHARGE AIR CONDITIONERS 13 SEER R-410A MODELS: YCHD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) TECHNICAL GUIDE HORIZONTAL DISCHARGE AIR CONDITIONERS 13 SEER R-410A MODELS: YCHD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

TECHNICAL GUIDE LISTED SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE)

TECHNICAL GUIDE LISTED SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE) TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE) LISTED ISO 9001 Certified Quality Management System Due to continuous product improvement,

More information

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS TECHNICAL GUIDE RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RAC13J18 THRU 60 Due to continuous product improvement, specifications are subject to change without

More information

LISTED TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A MODELS: THJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A MODELS: THJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES DESCRIPTION 560550-CTG-A-0310 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE MODELS: RHP13J30 THRU 60 (3 ) RHP SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS.

TECHNICAL GUIDE MODELS: RHP13J30 THRU 60 (3 ) RHP SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS. TECHNICAL GUIDE RHP SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS S: RHP13J30 THRU 60 (3 ) Due to continuous product improvement, specifications are subject to change without

More information

STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES SEER. MODELS E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES SEER. MODELS E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES (1295) STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES - 12.00 SEER S E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION These high efficiency EFH Series heat pump units are the outdoor

More information

TECHNICAL GUIDE MODELS: RAC14J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION

TECHNICAL GUIDE MODELS: RAC14J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION TECHNICAL GUIDE RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RAC14J18 THRU 60 Due to continuous product improvement, specifications are subject to change

More information

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A Single Phase MODELS: YHJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A Single Phase MODELS: YHJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY DESCRIPTION 571209-YTG-B-1211 The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: GHD, GFD, GFA, GNA, GUA & GHA CFM 2-5 TON COILS

TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: GHD, GFD, GFA, GNA, GUA & GHA CFM 2-5 TON COILS Heating TECHNICAL GUIDE Air Conditioning ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: GHD, GFD, GFA, GNA, GUA & GHA 600-2000 CFM 2-5 TON COILS R DESCRIPTION These cooling and heat

More information

Advance Information SPLIT SYSTEM HEAT PUMP 10 SEER. ERA 018 thru thru 5 NOMINAL TONS DESCRIPTION FEATURES

Advance Information SPLIT SYSTEM HEAT PUMP 10 SEER. ERA 018 thru thru 5 NOMINAL TONS DESCRIPTION FEATURES 515.16-TG1Y (1095) Advance Information SPLIT SYSTEM HEAT PUMP 10 S ERA 018 thru 060 1.5 thru 5 NOMINAL TONS DESCRIPTION The ERA series heat pumps are designed for use with a variety of YORK evaporator

More information

TECHNICAL GUIDE LISTED

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 MODELS: H*BD-F018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) H*BD-(T,W)036 THRU 060 (2.5 THRU 5 NOMINAL TONS, 3 PHASE) LISTED Due to continuous

More information

LISTED TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: YHJR18-60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: YHJR18-60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A S: YHJR18-60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) LISTED Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE MODELS: TCJD30 THRU 76 LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.3 NOMINAL TONS

TECHNICAL GUIDE MODELS: TCJD30 THRU 76 LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.3 NOMINAL TONS DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE (1.5 THRU 5 NOMINAL TONS)

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE (1.5 THRU 5 NOMINAL TONS) DESCRIPTION 840621-LTG-A-0612 The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A MODELS: TCJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A MODELS: TCJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES DESCRIPTION 700696-CTG-A-0312 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A Single Phase MODELS: YHJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A Single Phase MODELS: YHJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY DESCRIPTION 561923-YTG-C-1211 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6. DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

LISTED TECHNICAL GUIDE AFFINITY SPLIT-SYSTEM AIR CONDITIONERS 16 SEER R-410A MODELS: CZF024 THRU 060 (2 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE AFFINITY SPLIT-SYSTEM AIR CONDITIONERS 16 SEER R-410A MODELS: CZF024 THRU 060 (2 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES DESCRIPTION 567175-YTG-C-1010 The 16 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS DESCRIPTION

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS DESCRIPTION 571209-YTG-F-0615 DESCRIPTION The 14 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

SPLIT SYSTEM HEAT PUMP 12 SEER

SPLIT SYSTEM HEAT PUMP 12 SEER 515.18-TG1C (600) SPLIT SYSTEM HEAT PUMP 12 SEER 018 thru 060 1.5 thru 5 NOMINAL TONS GENERAL DESCRIPTION The series heat pumps are designed for use with a variety of UPG evaporator sections to suit any

More information

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6. DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

TECHNICAL GUIDE MODELS: THJD18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: THJD18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES DESCRIPTION 571471-LTG-C-1012 The 13 SEER Series unit is the outdoor part of a versatile climate system. It i76s designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

LISTED TECHNICAL GUIDE

LISTED TECHNICAL GUIDE TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 13 SEER R-22 MODELS: E*RD018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) E*RD030 THRU 060 (2.5 THRU 5 NOMINAL TONS, 3 PHASE) LISTED ISO 9001 Certified Quality Management

More information

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER - R-410A - 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: THJD18 THRU 60

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER - R-410A - 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: THJD18 THRU 60 Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER - R-410A - 1 PHASE 1.5 THRU 5 NOMINAL TONS S: THJD18 THRU 60 Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE MODELS: YCJF18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: YCJF18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES DESCRIPTION 700695-YTG-C-0714 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE MODELS: THJD30 THRU 60 (3 ) LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS.

TECHNICAL GUIDE MODELS: THJD30 THRU 60 (3 ) LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS. TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS S: THJD30 THRU 60 (3 ) Due to continuous product improvement, specifications are subject to change without

More information

LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER AY012MA THRU 030 (1 THRU 2.5 NOMINAL TONS, 1 PH)

LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER AY012MA THRU 030 (1 THRU 2.5 NOMINAL TONS, 1 PH) T R P T O N G 259800-YTG-B-0607 SPLT-SYSTEM AR CONDTONERS 13 SEER AY012MA THRU 030 (1 THRU 2.5 NOMNAL TONS, 1 PH) U R A C T MA N U F R E C E UN R T C ER T A R A RY F F E D E Q U C A T T S A T ON O M E

More information

TECHNICAL GUIDE MODELS: YHJR18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: YHJR18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS.     DESCRIPTION TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS.   DESCRIPTION FEATURE TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES TECHNICAL GUIDE MODELS: N*AH Modular Air Handlers For use w / Split System Cooling & Heat Pump 600-2000 CFM Blowers 2-5 Ton Coils Optional 1 & 3 Electric Heaters DESCRIPTION This unique modular system

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806 TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS HEAT PUMP MODELS: F2RP/F2FP018 THRU 060 F3RP/F3FP018 THRU 060(T) FXRP024 THRU 060 COOLING MODELS F2RC/F2FC024 THRU

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

TECHNICAL GUIDE HORIZONTAL DISCHARGE SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: TCHD18 THRU 60

TECHNICAL GUIDE HORIZONTAL DISCHARGE SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: TCHD18 THRU 60 TECHNICAL GUIDE HORIZONTAL DISCHARGE SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: TCHD18 THRU 60 Due to continuous product improvement, specifications are subject to

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING (598) STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING HEAT PUMP S: F2RP / F2FP018 THRU 060 COOLING S: F2RC / F2FC018 THRU 036 VARIABLE SPEED : F2FV060 DESCRIPTION This fan coil

More information

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton.

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton. AFAIR12B Air Conditioners Features Top discharge directs hot air and noise away from the living area Durable Copeland scroll compressor with internal pressure relief valves and inherent thermal protection

More information

WCA4**4. Product Specifications

WCA4**4. Product Specifications WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

TECHNICAL GUIDE MODELS: AC8B024 THRU 060* ECHELONTM SERIES SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS DESCRIPTION

TECHNICAL GUIDE MODELS: AC8B024 THRU 060* ECHELONTM SERIES SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS DESCRIPTION 1109218-CTG-B-0515 DESCRIPTION The 18 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from. Available for typical applications this

More information

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12. TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,

More information

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS TECHNICAL GUIDE AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: YZF024 THRU 060 Due to continuous product improvement, specifications are subject to change without

More information

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from

More information

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS TECHNICAL GUIDE AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: YZF024 THRU 060 Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE MODELS: CZH024 THRU 060* SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS AFFINITYTM SERIES DESCRIPTION

TECHNICAL GUIDE MODELS: CZH024 THRU 060* SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS AFFINITYTM SERIES DESCRIPTION 1109217-YTG-B-0515 DESCRIPTION The 18 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from. Available for typical applications this

More information

P5RF Series Single Packaged Air Conditioner Single Phase

P5RF Series Single Packaged Air Conditioner Single Phase TECHNICAL SPECIFICATIONS P5RF Series Single Packaged Air Conditioner Single Phase 15 SEER, 12 EER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P5 Series single packaged air conditioners

More information

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230

More information

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

10+ SEER - AIR CONDITIONER

10+ SEER - AIR CONDITIONER 10+ SEER AIR CONDITIONER 1 1 / 2 THRU 5 TONS SPLIT SYSTEM FEATURES Service valves on all models with 3 1 / 2 stubs External refrigerant connections Copper tube / aluminum fin coil Prepainted condenser

More information

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS TECHNICAL GUIDE CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL York s Champion package units are designed to

More information

TECHNICAL GUIDE AFFINITY TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: CZF024 THRU 060

TECHNICAL GUIDE AFFINITY TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: CZF024 THRU 060 TECHNICAL GUIDE AFFINITY TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: CZF024 THRU 060 Due to continuous product improvement, specifications are subject to change

More information

CAC SERIES 12-1/2 Thru 20 Ton

CAC SERIES 12-1/2 Thru 20 Ton CAC SERIES 12-1/2 Thru 20 Ton SPLIT SYSTEM COMMERCIAL AIR CONDITIONER CONSTRUCTION Triple step pre--painted galvanized steal pre--coated inside and out -- using a polyester top coat, over a urethane primer

More information

CSA6. Product Specifications. SoftSound SXC 2600

CSA6. Product Specifications. SoftSound SXC 2600 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS 550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION

More information

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01 PAB SERIES 3thru6-1/3Ton Belt Drive CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT 10 SEER SINGLE PACKAGE Electric cooling, self contained for year-round comfort. Systems can be installed on roof top

More information

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on

More information

10+ SEER - AIR CONDITIONER

10+ SEER - AIR CONDITIONER 10+ SEER AIR CONDITIONER 1 1 / 2 THRU 5 TONS SPLIT SYSTEM FEATURES Service valves on all models with 3 1 / 2 stubs External refrigerant connections Copper tube / aluminum fin coil Prepainted condenser

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information

PHB SERIES 7-1/2 and 10 TON

PHB SERIES 7-1/2 and 10 TON PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner P7RE 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency self

More information

TECHNICAL GUIDE R-410A AFFINITY SERIES DEZ MODELS 2-5 TON 60 Hertz

TECHNICAL GUIDE R-410A AFFINITY SERIES DEZ MODELS 2-5 TON 60 Hertz TECHNICAL GUIDE R-410A AFFINITY SERIES MODELS 2-5 TON 60 Hertz Description These York Affinity packaged air conditioners are designed for outdoor installation. Only utility and duct connections are required

More information

COMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

COMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT COMMERCIAL H4A3 DX 1300 Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT NXA6 Performance Series Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BG Series M1200 Product Line Ultra High Efficiency Air Conditioner 20 SEER Residential System 2-5 Ton Capacities 2 The iq Drive air conditioner system features modulating

More information

Q5RD Series Single Packaged Heat Pump, Single Phase

Q5RD Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The Q5 Series single packaged

More information

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON ALLEGIANCE 16 MODELS 4A7A6024,036,048 & 060B American Standard Inc. All Rights Reserved

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON ALLEGIANCE 16 MODELS 4A7A6024,036,048 & 060B American Standard Inc. All Rights Reserved SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON ALLEGIANCE 16 MODELS 4A7A6024,036,048 & 060B 2005 American Standard Inc. All Rights Reserved PUB. NO. 12-1200-02 March 2005 Features and Benefits Duration staged scroll

More information

SPLIT SYSTEM COOLING 2½, 3, 4 & 5 TON ALLEGIANCE 18 MODELS 2A7A8030, 036, 048 & 060B American Standard Inc. All Rights Reserved

SPLIT SYSTEM COOLING 2½, 3, 4 & 5 TON ALLEGIANCE 18 MODELS 2A7A8030, 036, 048 & 060B American Standard Inc. All Rights Reserved SPLIT SYSTEM COOLING 2½, 3, 4 & 5 TON ALLEGIANCE 18 MODELS 2A7A8030, 036, 048 & 060B 2005 American Standard Inc. All Rights Reserved PUB. NO. 12-1194-02 February 2005 Features and Benefits Two Duration

More information

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS GQ3RD Series Single Packaged Heat Pump, Single Phase GQ3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The GQ3 Series single packaged

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

TSA6. Product Specifications. SmartComfort TXC 5600

TSA6. Product Specifications. SmartComfort TXC 5600 ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230

More information

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS GP5RD Series Single Packaged Air Conditioner, Single Phase GP5RD-13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 60,000 Btuh The GP5 Series single packaged air conditioners

More information

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHA D SERIES UNITARY AIRCONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CONVERTIBLE SINGLE PACKAGE HEAT PUMP FEATURE SINGLE PACKAGE, 2 THRU 5 TON COOLING Single

More information

10AC DIPLOMAT SERIES RFC SYSTEMS

10AC DIPLOMAT SERIES RFC SYSTEMS 10AC DIPLOMAT SERIES CONDENSING UNITS RFC SYSTEMS 10.05 to 10.55 SEER *11,100 to 60,000 Btuh (3.3 to 17.6 ) 1 thru 5 Tons (3.5 to 17.6 ) *ARI and DOE Certified Ratings CONDENSING ENGINEERING UNITS DATA

More information

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS Q3RD Series Single Packaged Heat Pump, Single Phase Q3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The Q3 Series single packaged

More information

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES: PH13PA 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory

More information