LISTED TECHNICAL GUIDE
|
|
- Everett Floyd
- 6 years ago
- Views:
Transcription
1 TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 13 SEER R-22 MODELS: E*RD018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) E*RD030 THRU 060 (2.5 THRU 5 NOMINAL TONS, 3 PHASE) LISTED ISO 9001 Certified Quality Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at Additional rating information can be found at DESCRIPTION The 13 SEER series heat pumps are designed for use with a variety of UPG evaporator sections to suit any application need. A full line of matching Add-On Coils are available for use with upflow, downflow or horizontal furnaces. Matching Air Handlers are also available for upflow, downflow or horizontal installation to provide a complete system. Electric heat may be installed in air handlers. All units are factory charged to assure easy installation. WARRANTY Single Phase Units: 5-year limited parts warranty. 5-year limited compressor warranty. Three Phase Units: 1-year limited parts warranty. 5-year limited compressor warranty. FEATURES DURABLE CONSTRUCTION - The outdoor unit is constructed of pre-painted steel that offers tough protection against corrosion and resists fading when exposed to sunlight. Drain holes are incorporated into the base pan to permit free drainage of moisture. QUALITY COILS - The coil is constructed of enhanced copper tube and aluminum fins. COIL PROTECTION - Coils are protected from damage by a polymer mesh applied between the coil face, and a PVC coated steel coil guard. PROTECTED COMPRESSOR - The hermetic compressor is internally protected against high pressure and temperature by the simultaneous operation of a high pressure relief valve and temperature sensors which stop the compressor if operating temperatures go too high. Both protectors reset automatically. A discharge line solid core filter drier further protects the compressor. Complete System Control These heat pumps utilize the unique microprocessor defrost control system to provide optimal comfort and to monitor the overall system for reliable operation. The defrost control system continuously monitors the space environment to maintain optimum efficiency. It initiates defrost only when necessary to further reduce heating costs and improve reliability. In the event improper operating conditions occur, the control will automatically shut the system down to extend the life of the heat pump. Rapid cycling is prevented by use of an internal anti-recycle timer. LOW OPERATING SOUND LEVEL - The compressor is mounted on rubber isolators to reduce operating sounds. The slow moving condenser fan keeps air turbulence and sound to a low level. EASY ACCESS - Removable panel affords accessibility to the electrical box. FULLY CHARGED AND FACTORY WIRED - to simply installation and reduce labor costs. Only power supply and control wiring and refrigerant lines must be connected. All models are sweat connect with reusable service valves. Factory tested - to verify system operation and control functioning before shipment. U.L. and C.U.L. listed - approved for outdoor application. Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
2 Physical and Electrical Data - 1 Phase MODEL E1RD018S06 E1RD024S06 E1RD030S06 E1RD036S06 E1RD042S06 E1RD048S06 E1RD060S06 Unit Supply Voltage V, 1φ, 60Hz Normal Voltage Range to 252 Minimum Circuit Ampacity Max. Overcurrent Device Amps Min. Overcurrent Device Amps Compressor Type 4 Recip Recip Recip Recip Recip Scroll D Scroll D Compressor Rated Load Amps Locked Rotor Crankcase Heater Yes Yes Yes Yes Yes No No Fan Motor Amps Rated Load Fan Diameter Inches Rated HP 1/15 1/4 1/4 1/4 1/4 1/4 1/4 Fan Motor Nominal RPM Nominal CFM 2,000 3,250 3,450 3,500 3,500 3,400 3,500 Face Area Sq. Ft Coil Rows Deep Fin / Inches Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed) 3/4 3/4 7/8 7/8 7/8 7/8 1-1/8 Unit Charge (Lbs. - Oz.) Charge Per Foot, Oz Operating Weight Lbs Rated in accordance with ARI Standard 110, utilization range A. 2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection. 4. All scrolls listed with a superscript D are Danfoss scrolls. All scrolls listed with a superscript C are Copeland scrolls. 5. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. A B C Unit Model Dimensions (Inches) Refrigerant Connection Service Valve Size A 1 B C Liquid Vapor / / / /8 * 1. Including Fan Guard. * Adapter fitting required for 1-1/8 line set. 2 Unitary Products Group
3 Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase Outdoor Unit E1RD018S06 E1RD024S06 E1RD030S06 E1RD036S06 E1RD042S06 E1RD048S06 E1RD060S06 Required TXV 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1 Factory Charge, lbs-oz Indoor Coil 1,2 Additional Charge, Oz FC/MC/PC/UC18A2A 0 FC/MC/PC/UC18B2A 0 FC/MC/PC/UC24A2A 0 FC/MC/PC/UC24B2A 0 FC/MC/PC/UC30A2A 0 FC/MC/PC/UC30B2A 0 FC/MC/PC35B2A 0 9 FC/MC/PC35C2C 0 9 FC/MC/PC/UC42B2C 0 9 FC/MC/PC/UC42C2C 0 9 FC/MC/PC/UC48C2C 9 14 FC/MC/PC/UC48D2C 9 14 FC/PC/UC60C2C 7 7 FC/MC/PC/UC60D2C 7 7 MC61D2C 7 7 HC18A2A 0 HC30A2A 0 HC36B2A 0 HC42C2C 9 HC60C2C 7 7 HD24A2A 0 HD36B2A 0 9 HD48C2C 14 HD60D2C 7 7 AHP18B2A 0 AHP24B2A 0 AHP30B2A 0 AHP36C2A 9 AHP42C2C 9 AHP/SHP48D2C 14 7 AHP/SHP60D2C 7 7 AV24B2A 0 0 AV36C2A 0 9 AV/SV48D2C 14 7 AV/SV60D2C 7 FC/MC/PC/UC18A3X 0 FC/MC/PC/UC18B3X 0 FC/MC/PC/UC24A3X 0 FC/MC/PC/UC24B3X 0 FC/MC/PC/UC30A3X 0 FC/MC/PC/UC30B3X 0 FC/MC/PC35B3X 0 9 FC/MC/PC35X3X 0 9 FC/MC/PC/UC42B3X 0 9 FC/MC/PC/UC42X3X 0 9 FC/MC/PC/UC48C3X 9 14 FC/MC/PC/UC48D3X 9 14 FC/PC/UC60C3X 7 7 FC/MC/PC/UC60D3X 7 7 MC61D3X 7 7 HC18A3X 0 HC30A3X 0 HC36B3X 0 HC42C3X 9 HC60C3X 7 7 For Notes See Page 4. Unitary Products Group 3
4 Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase (Continued) Outdoor Unit E1RD018S06 E1RD024S06 E1RD030S06 E1RD036S06 E1RD042S06 E1RD048S06 E1RD060S06 Required TXV 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1 Factory Charge, lbs-oz Indoor Coil 1,2 Additional Charge, Oz HD24A3X 0 HD36B3X 0 9 HD48C3X 14 HD60D3X 7 7 AHP18B3X 0 AHP24B3X 0 AHP30B3X 0 AHP36C3X 9 AHP42C3X 9 AHP/SHP48D3X 14 7 AHP/SHP60D3X 7 7 AV24B3X 0 0 AV36C3X 0 9 AV/SV48D3X 14 7 AV/SV60D3X F*FP024H06T2A 0 F*FP030H06T2A 0 F*FP040H06T2A 0 9 F*FP042H06T2A 9 F*FV060H06T2C 7 7 FOOTNOTES: 1. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications. * This loose coil match does not achieve 13 SEER. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting line tubing. 2. Verify the orifice size and the additional charge required for the specific evaporator coil in the system using the above table. 3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base charge (as shipped) + adder for evaporator + adder for line set. 5. If the orifice in the evaporator was changed, verify the evaporator nameplate has been marked with the correct orifice/txv size. 4 Unitary Products Group
5 Physical and Electrical Data - 3 Phase MODEL E1RD E1RD E1RD E1RD E1RD E1RD E1RD E1RD E1RD E1RD 030S25 036S25 042S25 048S25 060S25 030S46 036S46 042S46 048S46 060S46 Unit Supply Voltage V, 3φ, 60Hz 460V, 3φ, 60Hz Normal Voltage Range to to 532 Minimum Circuit Ampacity Max. Overcurrent Device Amps Min. Overcurrent Device Amps Compressor Type Recip Recip Recip Scroll Scroll Recip Recip Recip Scroll Scroll Compressor Amps Rated Load Locked Rotor Crankcase Heater Yes Yes Yes No No Yes Yes Yes No No Fan Motor Amps Rated Load Fan Diameter Inches Rated HP 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 Fan Motor Nominal RPM Nominal CFM Face Area Sq. Ft Coil Rows Deep Fin / Inches Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed) 7/8 7/8 7/8 7/8 1-1/8 7/8 7/8 7/8 7/8 1-1/8 Unit Charge (Lbs. - Oz.) Charge Per Foot, Oz Operating Weight Lbs Rated in accordance with ARI Standard 110, utilization range A. 2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection. 4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. If line exceeds 25 feet, you may refer to publications software for proper line sizing. A C All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. DIMENSIONS Unit Model Dimensions (Inches) A 1 Refrigerant Connection Service Valve Size B C Liquid Vapor /8 7/ /8 * B 1. Including Fan Guard. * Adapter fitting required for 1-1/8 line set. Unitary Products Group 5
6 Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase Outdoor Unit E1RD030S(25,46) E1RD036S(25,46) E1RD042S(25,46) E1RD048S(25,46) E1RD060S(25,46) Required TXV 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1 Factory Charge, lbs-oz Indoor Coil 1 Additional Charge, Oz FC/MC/PC/UC35B2C 0 9 FC/MC/PC/UC35C2C 0 9 FC/MC/PC/UC42B2C 0 9 FC/MC/PC/UC42C2C 0 9 FC/MC/PC/UC48C2C 9 14 FC/MC/PC/UC48D2C 9 14 FC/PC/UC60C2C 7 5 FC/MC/PC/UC60D2C 7 5 MC61D2C 7 5 HC36B2A 0 HC42C2C 9 HC60C2C 7 5 HD36B2A 0 9 HD48C2C 14 HD60D2C 7 5 AHP30B2A 0 AHP36C2A 9 AHP42C2C 9 AHP/SHP48D2C 14 7 AHP/SHP60D2C 7 5 FC/MC/PC/UC42B3X 0 9 FC/MC/PC/UC42X3X 0 9 FC/MC/PC/UC48C3X 9 14 FC/MC/PC/UC48D3X 9 14 FC/PC/UC60C3X 7 5 FC/MC/PC/UC60D3X 7 5 MC61D3X 7 5 HC36B3X 0 HC42C3X 9 HC60C3X 7 5 HD36B3X 0 9 HD48C3X 14 HD60D3X 7 5 AHP30B3X 0 AHP36C3X 9 AHP42C3X 9 AHP/SHP48D3X 14 7 AHP/SHP60D3X 7 5 F*FP040H06T2A 0 9 F*FP042H06T2A 9 FOOTNOTES: 1. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of inter-connecting line tubing. 2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table. 3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set. 6 Unitary Products Group
7 COOLING CAPACITY - With Air Handler Coils UNIT MODEL AIR HANDLER MODEL W COIL MODEL 1 RATED CFM 1 & 3 PH 13 SEER HP WITH MA TOTAL NET MBH COOLING SENS YTG-H-0208 E1RD018S06 MA08B 17 FC/MC18B E1RD024S06 E1RD030S06 E1RD030S(25,46) E1RD036S06 E1RD036S(25,46) E1RD042S06 E1RD042S(25,46) E1RD048S06 E1RD048S(25,46) E1RD060S06 E1RD060S(25,46) SEER MA08B 17 FC/MC24B MA08B 17 FC/MC30B MA12B 17 FC/MC35B MA12B 17 FC/MC42B MA12B 17 FC/MC35B MA12B 17 FC/MC42B MA12B 17 FC/MC35B MA12B 17 FC/MC42B MA14D 24 FC/MC48D MA12B 17 FC/MC35B MA12B 17 FC/MC42B MA14D 24 FC/MC48D MA16C 21 FC/MC48C MA14D 24 FC/MC48D MA16C 21 FC/MC48C MA14D 24 FC/MC48D MA16C 21 FC60C MA20D 21 FC/MC60D MA20D 24 MC61D MA16C 21 FC60C MA20D 21 FC/MC60D MA20D 24 MC61D MA20D 24 FC/MC60D MA20D 24 MC61D MA20D 24 FC/MC60D MA20D 24 MC61D PH 13 SEER HP WITH MV - VARIABLE SPEED E1RD018S06 MV12B 17 FC/MC18B E1RD024S06 E1RD030S06 E1RD036S06 MV12B 17 FC/MC24B MV12B 17 FC/MC30B MV12B 17 FC/MC35B MV16C 21 FC/MC35C MV12B 17 FC/MC42B MV16C 21 FC/MC42C MV12B 21 FC/MC35C MV16C 21 FC/MC35C MV16C 21 FC/MC42C MV16C 21 FC/MC48C MV20D 24 FC/MC48D E1RD042S06 MV16C 21 FC/MC48C E1RD048S06 E1RD060S06 For Notes See Page 8 MV20D 24 FC/MC60D MV20D 24 MC61D MV20D 24 FC/MC60D MV20D 24 MC61D EER Unitary Products Group 7
8 COOLING CAPACITY - With Air Handler Coils (Continued) UNIT MODEL 1 PH 13 SEER AC WITH AV / SV - VARIABLE SPEED E1RD018S06 AV E1RD024S06 AV E1RD030S06 AV E1RD036S06 AV E1RD042S06 AV/SV E1RD048S06 AV/SV E1RD060S06 AV/SV E1RD018S06 E1RD024S06 E1RD030S06 E1RD030S(25,46) E1RD036S06 E1RD036S(25,46) 1 & 3 PH 13 SEER HP WITH AHP / F*FP / F*FV F*FP AHP F*FP AHP F*FP AHP F*FP AHP AHP F*FP F*FP AHP AHP F*FP F*FP AHP AHP E1RD042S06 AHP/SHP E1RD042S(25,46) AHP/SHP E1RD048S06 E1RD048S(25,46) E1RD060S06 E1RD060S(25,46) AIR HANDLER MODEL W COIL MODEL 1 RATED CFM TOTAL NET MBH COOLING SENS. F*FV AHP/SHP AHP/SHP F*FV AHP/SHP AHP/SHP F*FV AHP/SHP F*FV AHP/SHP Rated in accordance with DOE test procedures (Federal Register and ) and ARI Standards 210/240. Cooling MBH based on 80 F entering air temperature, 50% RH, and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTU s at a 95 F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number. = Not Applicable. Go to for the latest additional matches. SEER EER 8 Unitary Products Group
9 COOLING CAPACITY - Upflow, Downflow, and Horizontal Furnaces and Coils FURNACE** COIL UNIT MODEL W MODEL E1RD018S06 E1RD024S06 E1RD030S06 E1RD030S(25,46) E1RD036S06 E1RD036S(25,46) E1RD042S06 E1RD042S(25,46) E1RD048S06 E1RD048S(25,46) E1RD060S06 E1RD060S(25,46) CFM RANGE (MIN.-MAX.) COOLING YTG-H-0208 RATED NET MBH CFM TOTAL SENS. SEER 1 EER 14,17 FC/MC/PC/UC HC ,17 FC/MC/PC/UC ,17 FC/MC/PC/UC HC HD ,21 FC/MC/PC ,21 FC/MC/PC/UC HC HD ,21 FC/MC/PC ,21 FC/MC/PC/UC HC HD ,21 FC/MC/PC ,21 FC/MC/PC/UC ,24 FC/MC/PC/UC HC HD ,21 FC/MC/PC ,21 FC/MC/PC/UC ,24 FC/MC/PC/UC HC HD ,24 FC/MC/PC/UC HD ,24 FC/MC/PC/UC HD ,24 FC/MC/PC/UC MC HC HD ,24 FC/MC/PC/UC MC HC HD ,24 FC/MC/PC/UC MC HC HD ,24 FC/MC/PC/UC MC HC HD Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. Unitary Products Group 9
10 COOLING CAPACITY - With Variable Speed Furnaces UNIT MODEL E1RD018S06 E1RD024S06 E1RD030S06 E1RD036S06 E1RD042S06 For Notes See Page 11 VARIABLE SPEED FURNACE MODEL COIL MODEL 1 W RATED CFM TOTAL 1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES 2 NET MBH COOLING SENS. SEER PV8*A12 FC/MC/PC18A PV9*A12 FC/MC/PC18A P(C,V)9*B12 FC/MC/PC18B PV8*A12 HC PV9*A12 HC PV8*A12 FC/MC/PC24A PV9*A12 FC/MC/PC24A P(C,V)9*B12 FC/MC/PC24B PV8*A12 FC/MC/PC30A PV9*A12 FC/MC/PC30A P(C,V)9*B12 FC/MC/PC30B PV8*A12 HC PV9*A12 HC PV8*A12 HD PV9*A12 HD PV8*B16 FC/MC/PC35B P(C,V)9*B12 FC/MC/PC35B PV8*C16 FC/MC/PC35C P(C,V)9*C16 FC/MC/PC35C PV8*B16 FC/MC/PC42B P(C,V)9*B12 FC/MC/PC42B PV8*C16 FC/MC/PC42C P(C,V)9*C16 FC/MC/PC42C PV8*B16 HC P(C,V)9*B12 HC PV8*B16 HD P(C,V)9*B12 HD PV8*B16 FC/MC/PC42B P(C,V)9*B12 FC/MC/PC42B PV8*C16 FC/MC/PC42C PV8*C20 FC/MC/PC42C P(C,V)9*C16 FC/MC/PC42C P(C,V)9*C20 FC/MC/PC42C PV8*C20 FC/MC/PC48C P(C,V)9*C16 FC/MC/PC48C P(C,V)9*C20 FC/MC/PC48C P(C,V)9*D20 FC/MC/PC48D PV8*C20 HC P(C,V)9*C16 HC P(C,V)9*C20 HC PV8*C20 HD P(C,V)9*C16 HD P(C,V)9*C20 HD PV8*C20 FC/MC/PC48C P(C,V)9*C16 FC/MC/PC48C P(C,V)9*C20 FC/MC/PC48C P(C,V)9*D20 FC/MC/PC48D PV8*C20 HD P(C,V)9*C16 HD P(C,V)9*C20 HD EER 10 Unitary Products Group
11 COOLING CAPACITY - With Variable Speed Furnaces (Continued) COOLING VARIABLE SPEED COIL UNIT MODEL FURNACE MODEL MODEL 1 W RATED NET MBH CFM TOTAL SENS. 1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES 2 E1RD048S06 E1RD060S YTG-H-0208 P(C,V)9*D20 FC/MC/PC60D PV8*C16 FC/PC60C PV8*C20 FC/PC60C P(C,V)9*C16 FC/PC60C P(C,V)9*C20 FC/PC60C P(C,V)9*D20 HC PV8*C20 HD P(C,V)9*C20 HD P(C,V)9*D20 MC61D P(C,V)9*D20 FC/MC/PC60D PV8*C20 FC/PC60C P(C,V)9*C20 FC/PC60C P(C,V)9*D20 HC PV8*C20 HD P(C,V)9*D20 HD P(C,V)9*D20 MC61D MC coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2. Variable speed furnaces have B.O.D (Blower on Delay) standard. SEER EER Unitary Products Group 11
12 HEATING PERFORMANCE - With Air Handler UNIT MODEL* AIR HANDLER COIL 1 MODEL 1 & 3 PH 13 SEER HP WITH MA ARI HEATING 2 47 F 17 F HSPF MBH COP KW MBH COP KW STD E1RD018S06 MA08B FC/MC18B E1RD024S06 MA08B FC/MC24B MA08B FC/MC30B E1RD030S06 MA12B FC/MC35B MA12B FC/MC42B E1RD030S(25,46) MA12B FC/MC35B MA12B FC/MC42B MA12B FC/MC35B E1RD036S06 MA12B FC/MC42B MA14D FC/MC48D MA12B FC/MC35B E1RD036S(25,46) MA12B FC/MC42B MA14D FC/MC48D E1RD042S06 MA14D FC/MC48D MA16C FC/MC48C E1RD042S(25,46) MA14D FC/MC48D MA16C FC/MC48C MA16C FC60C E1RD048S06 MA20D FC/MC60D MA20D MC61D MA16C FC60C E1RD048S(25,46) MA20D FC/MC60D MA20D MC61D E1RD060S06 MA20D FC/MC60D MA20D MC61D E1RD060S(25,46) MA20D FC/MC60D MA20D MC61D PH 13 SEER HP WITH MV - VARIABLE SPEED E1RD018S06 MV12B FC/MC18B E1RD024S06 MV12B FC/MC24B MV12B FC/MC30B MV12B FC/MC35B E1RD030S06 MV16C FC/MC35C MV12B FC/MC42B MV16C FC/MC42C MV16C FC/MC35C E1RD036S06 MV16C FC/MC42C MV16C FC/MC48C MV20D FC/MC48D E1RD042S06 MV16C FC/MC48C MV20D FC/MC48D E1RD048S06 MV20D FC/MC60D MV20D MC61D E1RD060S06 MV20D FC/MC60D MV20D MC61D For Notes See Page Unitary Products Group
13 HEATING PERFORMANCE - With Air Handler (Continued) UNIT AIR COIL 1 ARI HEATING 2 47 F 17 F HSPF MODEL* HANDLER MODEL MBH COP KW MBH COP KW STD 1 PH 13 SEER HP WITH AV - VARIABLE SPEED E1RD018S06 AV E1RD024S06 AV E1RD030S06 AV E1RD036S06 AV E1RD042S06 AV/SV E1RD048S06 AV/SV E1RD060S06 AV/SV & 3 PH HP SEER AC WITH AHP / F*FP / F*FV E1RD018S06 AHP F*FP E1RD024S06 AHP F*FP E1RD030S06 AHP F*FP E1RD030S(25,46) AHP F*FP AHP E1RD036S06 AHP F*FP F*FP AHP E1RD036S(25,46) AHP F*FP F*FP E1RD042S06 AHP E1RD042S(25,46) AHP F*FV E1RD048S06 AHP AHP F*FV E1RD048S(25,46) AHP AHP E1RD060S06 F*FV AHP E1RD060S(25,46) F*FV AHP Rated CFM same as for cooling. 2. Heating MBH based on ARI standards of 70 DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation. CP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. = Not Applicable. Unitary Products Group 13
14 HEATING PERFORMANCE - Upflow Furnace Coils UNIT MODEL* E1RD018S06 E1RD024S06 E1RD030S06 E1RD030S(25,46) E1RD036S06 E1RD036S(25,46) E1RD042S06 E1RD042S(25,46) E1RD048S06 E1RD048S(25,46) E1RD060S06 E1RD060S(25,46) COIL 1 ARI HEATING 2 47 F 17 F HSPF MODEL MBH COP KW MBH COP KW STD FC/MC/PC/UC HC FC/MC/PC/UC FC/MC/PC/UC HC HD FC/MC/PC FC/MC/PC/UC/ HC HD FC/MC/PC FC/MC/PC/UC/ HC HD FC/MC/PC FC/MC/PC/UC/ FC/MC/PC/UC/ HC HD FC/MC/PC FC/MC/PC/UC/ FC/MC/PC/UC/ HC HD FC/MC/PC/UC HD FC/MC/PC/UC HD FC/MC/PC/UC HC HD MC FC/MC/PC/UC HC HD MC FC/MC/PC/UC HC HD MC FC/MC/PC/UC HC HD MC Rated CFM same as for cooling. 2. Heating MBH based on ARI standards of 70 DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation. CP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. = Not Applicable. 14 Unitary Products Group
15 HEATING CAPACITY - With Variable Speed Furnaces YTG-H-0208 UNIT MODEL E1RD018S06 E1RD024S06 E1RD030S06 E1RD036S06 For Notes See Page 16. VARIABLE SPEED FURNACE COIL 1 MODEL ARI HEATING 2 47 F 17 F HSPF MBH COP KW MBH COP KW STD PV8*A12 FC/MC/PC18A PV9*A12 FC/MC/PC18A P(C,V)9*B12 FC/MC/PC18B PV9*A12 HC PV8*A12 HC PV8*A12 FC/MC/PC24A PV9*A12 FC/MC/PC24A P(C,V)9*B12 FC/MC/PC24B PV8*A12 FC/MC/PC30A PV9*A12 FC/MC/PC30A P(C,V)9*B12 FC/MC/PC30B PV9*A12 HC PV8*A12 HC PV8*B16 FC/MC/PC35B P(C,V)9*B12 FC/MC/PC35B PV8*C20 FC/MC/PC35C P(C,V)9*C16 FC/MC/PC35C PV8*B16 FC/MC/PC42B P(C,V)9*B12 FC/MC/PC42B PV8*C20 FC/MC/PC42C P(C,V)9*C16 FC/MC/PC42C PV8*B16 HC PV8*C16 HC PV8*C16 HD P(C,V)9*C16 HD PV8*B16 FC/MC/PC35B P(C,V)9*B12 FC/MC/PC35B PV8*C16 FC/MC/PC35C PV8*C20 FC/MC/PC35C P(C,V)9*C16 FC/MC/PC35C P(C,V)9*C20 FC/MC/PC35C PV8*B16 FC/MC/PC42B P(C,V)9*B12 FC/MC/PC42B PV8*C16 FC/MC/PC42C PV8*C20 FC/MC/PC42C P(C,V)9*C16 FC/MC/PC42C P(C,V)9*C20 FC/MC/PC42C PV8*C20 FC/MC/PC48C P(C,V)9*C16 FC/MC/PC48C P(C,V)9*C20 FC/MC/PC48C P(C,V)9*D20 FC/MC/PC48D PV8*C20 HC P(C,V)9*C16 HC P(C,V)9*C20 HC PV8*C20 HD P(C,V)9*C16 HD P(C,V)9*C20 HD Unitary Products Group 15
16 HEATING CAPACITY - With Variable Speed Furnaces (Continued) UNIT MODEL E1RD042S06 E1RD048S06 E1RD060S06 VARIABLE SPEED COIL 1 ARI HEATING 2 47 F 17 F HSPF FURNACE MODEL MBH COP KW MBH COP KW STD PV8*C20 FC/MC/PC48C P(C,V)9*C16 FC/MC/PC48C P(C,V)9*C20 FC/MC/PC48C P(C,V)9*D20 FC/MC/PC48D PV8*C20 HD P(C,V)9*C16 HD P(C,V)9*C20 HD P(C,V)9*D20 FC/MC/PC60D PV8*C16 FC/PC60C PV8*C20 FC/PC60C P(C,V)9*C16 FC/PC60C P(C,V)9*C20 FC/PC60C P(C,V)9*C20 HC PV8*C20 HD P(C,V)9*C20 HD P(C,V)9*D20 MC61D P(C,V)9*D20 FC/MC/PC60D PV8*C20 FC/PC60C P(C,V)9*C20 FC/PC60C P(C,V)9*D20 HC PV8*C20 HD P(C,V)9*D20 HD P(C,V)9*D20 MC61D Rated CFM same as for cooling. 2. Heating MBH based on ARI standards of 70 DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation. CP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. = Not Applicable. 16 Unitary Products Group
17 ACCESSORIES Refer to Price Manual for specific model numbers. Start Assist Kit (2SA067*) Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied. Hard Start Kits - Provides required starting torque for use with Thermal Expansion Valve Kit. Low Temperature Cutout (2LT ) - Prevents heat pump operation below -10 F ambient temperature. Compressor Blanket - Designed to further reduce the normal operating sound. Add-on Fossil Fuel Control - Interface controls for use with gas, oil furnaces and the heat pump system are available. Thermal Expansion Valve Kit - 1TVM700 Series TXV kit used to improve system performance. Outdoor Thermostat (2TD ) - Provides additional staging of supplemental electric heat. INSTALLATION CLEARANCES Room Thermostats - A wide selection of matching thermostats is available to provide features required for any installation. 2H/1C, manual changeover electronic non-programmable thermostat. 3H/2C, non-programmable digital thermostat. 3H/2C, auto/manual changeover, electronic programmable, 7-day, hardwire thermostat. * For the most current accessory information, refer to the price book or consult factory. SOUND POWER RATINGS UNIT MODEL (dba)* Cooling Heating * Rated in accordance with ARI Standards. 60 OVERHEAD CLEARANCE 10 CLEARANCE COIL AREA MINIMUM 18 SERVICE ACCESS CLEARANCE ON ONE SIDE WEATHERPROOF DISCONNECT SWITCH THERMOSTAT TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING NEC CLASS 2 WIRING TO INDOOR COIL NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF. SEAL OPENING(S) WITH PERMAGUM OR EQUIVALENT CONTROL ACCESS PANEL TYPICAL FIELD WIRING ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES THERMOSTAT INDOOR UNIT DEFROST CONTROL R B or C Y O W L or X G T 2 E 2 1 FIELD INSTALLED JUMPER R C Y O W2 G W1 BK RED R BLK C YEL Y ORG O BRN W PUR X/L WHT W1/66 5GRY CC CONTACTOR T2 T1 M L2 L1 GND. SCREW JUMPER TERMINALS E AND W TOHEAT ON FIRST STAGE DURING EMERGENCY HEAT. TERMINAL NOT USED ON ALL THERMOSTATS. POWER WIRING 24V CONTROL WIRING (NEC CLASS 2) DEHUMIDIFICATION CONTROL CONNECTION (Humidistat* Jumper must be removed) GND. LUG CIRCUIT BREAKER*** POWER WIRING 208/ CHECK THE LOW VOLTAGE TERMINAL BLOCK ON THE INDOOR UNIT FOR THE ACTUAL ARRANGEMENT OF THE TERMINALS. 4 CONNECT POWER WIRING TO TERMINAL BLOCK 3TB ON UNITS WITHOUT ELECTRIC HEAT OR CIRCUIT BREAKER. 5 GRAY FOR USE WITH OPTIONAL OUTDOOR THERMOSTAT KITS. Unitary Products Group 17
18 COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. E1RD018S06 INDOOR COIL MODEL NO. FC/MC/PC/UC18 CONDENSER ID CFM ENTERING AIR ID DB ( F) TEMPERATURE ID WB ( F) T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature. Air Handler Coil T.C. S.C. KW MA08B FC/MC18B AHP F*FP MV12B FC/MC18B AV HC Variable Speed Furnace Coil T.C. S.C. KW PV8*A12 FC/MC/PC18A PV9*A12 FC/MC/PC18A P(C,V)9*B12 FC/MC/PC18B PV8*A12 HC PV9*A12 HC Unitary Products Group
19 COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. E1RD024S06 INDOOR COIL MODEL NO. FC/MC/PC/UC24 CONDENSER ID CFM ENTERING AIR ID DB ( F) TEMPERATURE ID WB ( F) T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature. Air Handler Coil T.C. S.C. KW MA08B FC/MC24B MA08B FC/MC30B AHP F*FP MV12B FC/MC24B MV12B FC/MC30B AV FC/MC/PC/UC HC HD Variable Speed Furnace Coil T.C. S.C. KW PV8*A12 FC/MC/PC24A PV9*A12 FC/MC/PC24A P(C,V)9*B12 FC/MC/PC24B PV8*A12 FC/MC/PC30A PV9*A12 FC/MC/PC30A P(C,V)9*B12 FC/MC/PC30B PV8*A12 HC PV9*A12 HC PV8*A12 HD PV9*A12 HD Unitary Products Group 19
20 COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. E1RD030S06, E1RD030S(25,46)** INDOOR COIL MODEL NO. FC/MC/PC35 CONDENSER ID CFM ENTERING AIR ID DB ( F) TEMPERATURE ID WB ( F) T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. ** For three-phase, decrease T.C. by 1.0 and S.C. by 0.7. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature. Air Handler Coil T.C. S.C. KW MA12B FC/MC35B MA12B FC/MC42B AHP F*FP MV12B* FC/MC35B MV12B* FC/MC42B MV16C* FC/MC35C MV16C* FC/MC42C AV36* FC/MC/PC/UC HC HD Variable Speed Furnace * Coil T.C. S.C. KW PV8*B16 FC/MC/PC35B P(C,V)9*B12 FC/MC/PC35B PV8*C16 FC/MC/PC35C P(C,V)9*C16 FC/MC/PC35C PV8*B16 FC/MC/PC42B P(C,V)9*B12 FC/MC/PC42B PV8*C16 FC/MC/PC42C P(C,V)9*C16 FC/MC/PC42C PV8*B16 HC P(C,V)9*B12 HC PV8*B16 HD P(C,V)9*B12 HD Unitary Products Group
21 COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. E1RD036S06, E1RD036S(25,46)** INDOOR COIL MODEL NO. FC/MC/PC/UC48 CONDENSER ID CFM ENTERING AIR ID DB ( F) TEMPERATURE ID WB ( F) T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. ** For three-phase, decrease T.C. by 1.0 and S.C. by 0.7. Multipliers for determining the performance with other indoor sections NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature. Air Handler Coil T.C. S.C. KW MA12B FC/MC35B MA12B FC/MC42B MA16C FC/MC35C MA16C FC/MC42C MA14D FC/MC48D AHP F*FP F*FP MV16C* FC/MC35C MV16C* FC/MC42C MV16C* FC/MC48C MV20D* FC/MC48D AV36* FC/MC/PC/ FC/MC/PC/UC HC HD Variable Speed Furnace * Coil T.C. S.C. KW PV8*B16 FC/MC/PC35B P(C,V)9*B12 FC/MC/PC35B PV8*C16 FC/MC/PC35C PV8*C20 FC/MC/PC35C P(C,V)9*C16 FC/MC/PC35C P(C,V)9*C20 FC/MC/PC35C PV8*B16 FC/MC/PC42B P(C,V)9*B12 FC/MC/PC42B PV8*C16 FC/MC/PC42C PV8*C20 FC/MC/PC42C P(C,V)9*C16 FC/MC/PC42C P(C,V)9*C20 FC/MC/PC42C PV8*C20 FC/MC/PC48C P(C,V)9*C16 FC/MC/PC48C P(C,V)9*C20 FC/MC/PC48C P(C,V)9*D20 FC/MC/PC48D PV8*C20 HC P(C,V)9*C16 HC P(C,V)9*C20 HC PV8*C20 HD P(C,V)9*C16 HD P(C,V)9*C20 HD Unitary Products Group 21
TECHNICAL GUIDE LISTED
TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 MODELS: H*BD-F018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) H*BD-(T,W)036 THRU 060 (2.5 THRU 5 NOMINAL TONS, 3 PHASE) LISTED Due to continuous
More informationTECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)
TECHNICAL GUIDE TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE S: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS) LISTED Due to continuous product improvement, specifications are subject
More informationTECHNICAL GUIDE LISTED SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE)
TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE) LISTED ISO 9001 Certified Quality Management System Due to continuous product improvement,
More informationLISTED TECHNICAL GUIDE HORIZONTAL DISCHARGE AIR CONDITIONERS 13 SEER R-410A MODELS: YCHD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE)
TECHNICAL GUIDE HORIZONTAL DISCHARGE AIR CONDITIONERS 13 SEER R-410A MODELS: YCHD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) LISTED ISO 9001 Certified Quality Management System Due to continuous product
More informationTECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 MODELS: GCGD12 THRU 60 (1 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES
TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 S: GCGD12 THRU 60 (1 THRU 5 NOMINAL TONS, 1 PHASE) LISTED Due to continuous product improvement, specifications are subject to change without
More informationLISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE MODELS: YCJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES
DESCRIPTION 364834-YTG-H-0509 The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available
More informationLISTED TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A MODELS: THJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES
DESCRIPTION 560550-CTG-A-0310 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available
More informationTECHNICAL GUIDE MODELS: RHP14J18 THRU 60 RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES
TECHNICAL GUIDE RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RHP14J18 THRU 60 Due to continuous product improvement, specifications are subject to change without
More informationTECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A Single Phase MODELS: YHJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY
DESCRIPTION 561923-YTG-C-1211 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available
More informationTECHNICAL GUIDE MODELS: RHP13J30 THRU 60 (3 ) RHP SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS.
TECHNICAL GUIDE RHP SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS S: RHP13J30 THRU 60 (3 ) Due to continuous product improvement, specifications are subject to change without
More informationTECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A Single Phase MODELS: YHJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY
DESCRIPTION 571209-YTG-B-1211 The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available
More informationLISTED TECHNICAL GUIDE AFFINITY SPLIT-SYSTEM AIR CONDITIONERS 16 SEER R-410A MODELS: CZF024 THRU 060 (2 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES
DESCRIPTION 567175-YTG-C-1010 The 16 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available
More informationLISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER AY012MA THRU 030 (1 THRU 2.5 NOMINAL TONS, 1 PH)
T R P T O N G 259800-YTG-B-0607 SPLT-SYSTEM AR CONDTONERS 13 SEER AY012MA THRU 030 (1 THRU 2.5 NOMNAL TONS, 1 PH) U R A C T MA N U F R E C E UN R T C ER T A R A RY F F E D E Q U C A T T S A T ON O M E
More informationTECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS
TECHNICAL GUIDE RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RAC13J18 THRU 60 Due to continuous product improvement, specifications are subject to change without
More informationTECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS
TECHNICAL GUIDE RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RAC13J18 THRU 60 Due to continuous product improvement, specifications are subject to change without
More informationLISTED TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: YHJR18-60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES
TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A S: YHJR18-60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) LISTED Due to continuous product improvement, specifications are subject to change without
More informationTECHNICAL GUIDE LISTED
P G TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 10 SEER MODELS: HP018X10* THRU 060X10* (1.5 THRU 5 NOMINAL TONS) HP036X10* THRU 060X10* (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management
More informationTECHNICAL GUIDE MODELS: THJD30 THRU 60 (3 ) LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS.
TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS S: THJD30 THRU 60 (3 ) Due to continuous product improvement, specifications are subject to change without
More informationTECHNICAL GUIDE MODELS: RAC14J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION
TECHNICAL GUIDE RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RAC14J18 THRU 60 Due to continuous product improvement, specifications are subject to change
More informationTECHNICAL GUIDE MODELS: TCJD30 THRU 76 LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.3 NOMINAL TONS
DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical
More informationUARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60
TECHNICAL GUIDE GUARDIAN SERIES DRY SHIP AIR CONDITIONER CONDENSING UNITS SHIPPED WITH NITROGEN CHARGE ONLY 13 SEER R-22 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: GCGD18 THRU 60 UARDIAN Due to continuous
More informationTECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.
DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical
More informationTECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE (1.5 THRU 5 NOMINAL TONS)
DESCRIPTION 840621-LTG-A-0612 The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available
More informationTechnical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS DESCRIPTION
571209-YTG-F-0615 DESCRIPTION The 14 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available
More informationTECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A MODELS: TCJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES
DESCRIPTION 700696-CTG-A-0312 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available
More informationTECHNICAL GUIDE MODELS: THJD18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES
DESCRIPTION 571471-LTG-C-1012 The 13 SEER Series unit is the outdoor part of a versatile climate system. It i76s designed with a matching indoor coil component from Johnson Controls Unitary Products. Available
More informationAdvance Information SPLIT SYSTEM HEAT PUMP 10 SEER. ERA 018 thru thru 5 NOMINAL TONS DESCRIPTION FEATURES
515.16-TG1Y (1095) Advance Information SPLIT SYSTEM HEAT PUMP 10 S ERA 018 thru 060 1.5 thru 5 NOMINAL TONS DESCRIPTION The ERA series heat pumps are designed for use with a variety of YORK evaporator
More informationTECHNICAL GUIDE MODELS: YHJR18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES
DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical
More informationTECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.
DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical
More informationSPLIT SYSTEM HEAT PUMP 12 SEER
515.18-TG1C (600) SPLIT SYSTEM HEAT PUMP 12 SEER 018 thru 060 1.5 thru 5 NOMINAL TONS GENERAL DESCRIPTION The series heat pumps are designed for use with a variety of UPG evaporator sections to suit any
More informationSPLIT SYSTEM HEAT PUMPS. ERA Series 10 SEER Single and Three Phase TECHNICAL SPECIFICATIONS
515.16-TG1Y (499) TECHNICAL SPECIFICATIONS SPLIT SYSTEM HEAT PUMPS Models 018-060 1Ø 036, 048 3Ø ERA Series 10 SEER Single and Three Phase Models ERA 018 thru ERA090 Nominal Capacity: 18 thru 90 MBH Models
More informationTECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS
TECHNICAL GUIDE AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: YZF024 THRU 060 Due to continuous product improvement, specifications are subject to change without
More informationTECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS
TECHNICAL GUIDE AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: YZF024 THRU 060 Due to continuous product improvement, specifications are subject to change without
More informationTECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS
DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical
More informationTechnical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER - R-410A - 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: THJD18 THRU 60
Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER - R-410A - 1 PHASE 1.5 THRU 5 NOMINAL TONS S: THJD18 THRU 60 Due to continuous product improvement, specifications are subject to change without
More informationTECHNICAL GUIDE MODELS: YCJF18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES
DESCRIPTION 700695-YTG-C-0714 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available
More informationTECHNICAL GUIDE DESCRIPTION
TECHNICAL GUE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER S: BRCS018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) H*BA-(T,W)036 THRU 090 (3 THRU 7.5 NOMINAL TONS, 3 PH) S: 018-060 (1 PH & 3 PH) S: 076-090 (3 PH)
More informationTECHNICAL GUIDE HORIZONTAL DISCHARGE SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: TCHD18 THRU 60
TECHNICAL GUIDE HORIZONTAL DISCHARGE SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: TCHD18 THRU 60 Due to continuous product improvement, specifications are subject to
More informationTECHNICAL GUIDE LISTED
T I I I T G TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER MODELS: H*BA018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) H*BA036(25,46) THRU 090 (3 THRU 7.5 NOMINAL TONS, 3 PH) This product was manufactured
More informationTECHNICAL GUIDE MODELS: CZH024 THRU 060* SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS AFFINITYTM SERIES DESCRIPTION
1109217-YTG-B-0515 DESCRIPTION The 18 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from. Available for typical applications this
More informationTECHNICAL GUIDE MODELS: AC8B024 THRU 060* ECHELONTM SERIES SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS DESCRIPTION
1109218-CTG-B-0515 DESCRIPTION The 18 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from. Available for typical applications this
More informationTECHNICAL GUIDE LISTED
E T I I I R P I T G TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: H*BC-F018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH)H*BC- (T,W)036 THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001
More informationLISTED TECHNICAL GUIDE STELLAR 2000 TM
E T I I I R P I T I O I N G TECHNICAL GUIDE STELLAR 2000 TM SPLIT-SYSTEM AIR CONDITIONERS 10 SEER S: H*DB018 THRU 060 (1 THRU 5 NOMINAL TONS, 1 PH) H*DB036 THRU 076 (3 THRU 6-1/3 NOMINAL TONS, 3 PH) This
More informationTECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: AC018X12* THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH)
E T I I I R P I T G TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: AC018X12* THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) LISTED ISO 9001 Certified Quality Management System CERTIFICATION APPLIES
More informationTECHNICAL GUIDE AFFINITY TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: CZF024 THRU 060
TECHNICAL GUIDE AFFINITY TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: CZF024 THRU 060 Due to continuous product improvement, specifications are subject to change
More informationLISTED TECHNICAL GUIDE AFFINITY R-410A SPLIT-SYSTEM AIR CONDITIONERS UP TO 18 SEER MODELS: CZE024 THRU 060 (2 THRU 5 NOMINAL TONS)
E T I I I R P I T G 036-21592-002 Rev. A (1204) TECHNICAL GUIDE AFFINITY R-410A SPLIT-SYSTEM AIR CONDITIONERS UP TO 18 SEER MODELS: CZE024 THRU 060 (2 THRU 5 NOMINAL TONS) U R A C T MA N U F R C E UN I
More informationLISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES
P G 036-21342-002 Rev. C (0902) TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) U R MA N U F A CT R E C E CE R T I F R T I UN I TA RY A R I F I
More informationSTELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES SEER. MODELS E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES
(1295) STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES - 12.00 SEER S E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION These high efficiency EFH Series heat pump units are the outdoor
More informationTECHNICAL GUIDE 16 SEER 2-5 TON AIR CONDITIONING SPLIT-SYSTEM COOLING H4TS024 H4TS030 H4TS036 H4TS048 H4TS060 DESCRIPTION FEATURES MODELS:
036-21023-002 Rev A (5/00) TECHNICAL GUIDE 16 SEER 2-5 TON CONDITIONING SPLIT-SYSTEM COOLING DESCRIPTION The HTS Stealth series condensing units use Twin Single compressor technology to provide cooling
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806
TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS HEAT PUMP MODELS: F2RP/F2FP018 THRU 060 F3RP/F3FP018 THRU 060(T) FXRP024 THRU 060 COOLING MODELS F2RC/F2FC024 THRU
More informationTECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE
TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More informationTECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION
TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationR-22, 13 SEER 60 Hertz
TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY
TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable
More informationHCH6. Product Specifications
HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland
More informationR4H4. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationZHA/ZHB SERIES WARNING
Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationFSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities
TECHNICAL SPECIFICATIONS FSH1BG Series Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities The iq Drive heat pump system features modulating compressor technology and variable
More informationET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity
TECHNICAL SPECIFICATIONS ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity ET4BE Series now offers the choice of a heat pump that uses a more efficient and environmentally
More information10+ SEER - AIR CONDITIONER
10+ SEER AIR CONDITIONER 1 1 / 2 THRU 5 TONS SPLIT SYSTEM FEATURES Service valves on all models with 3 1 / 2 stubs External refrigerant connections Copper tube / aluminum fin coil Prepainted condenser
More informationQ5RD Series Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The Q5 Series single packaged
More informationEFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER
ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230
More informationQ7RE Series Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged
More informationR4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT
EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors
More informationFORM NO. PTZ-806 REV. 1 HEAT PUMPS
FORM NO. PTZ-806 REV. 1 TZPLS-14 SERIES Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured for Thermal
More information14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum
FORM NO. PTZ-803 Supersedes Form No. PTZ-781 Featuring Industry Standard R-410A Refrigerant TZPL SERIES Efficiencies up to 14.5 SEER/12.00 EER/8.50 HSPF Nominal Sizes 1.5 to 5 Tons [5.28 kw] to [17.6 kw]
More informationWCA4**4. Product Specifications
WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationProduct Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS
DUCTED HEAT PUMP Sizes 018 To 060 1.5 To 5 Nominal Tons Product Data A08379 INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency S Sound S Levels as low as 71 dba Design Features S New aesthetics S Small
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSA4BG Series M1200 Product Line Ultra High Efficiency Air Conditioner 20 SEER Residential System 2-5 Ton Capacities 2 The iq Drive air conditioner system features modulating
More informationJT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY
TECHNICAL SPECIFICATIONS JT4BD Series R-410A High Efficiency Heat Pump 13 SEER Residential System 1.5 5 Ton Capacity The JT4BD Series now offers the choice of a heat pump that uses a more efficient and
More informationJT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1.
TECHNICAL SPECIFICATIONS JT4BE Series High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The JT4BE Series of heat pumps offers exceptional performance. The unit, when combined with
More informationQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS
TECHNICAL SPECIFICATIONS Q3RD Series Single Packaged Heat Pump, Single Phase Q3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The Q3 Series single packaged
More informationProduct Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:
PH13PA 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory
More information14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES
FORM NO. PTZ-781 Supersedes Form No. PTZ-781 Featuring New Industry Standard R-410A Refrigerant TZPL SERIES Manufactured for Thermal Zone Philadelphia, PA (IN CERTAIN MATCHED SYSTEMS) 14.5 SEER HEAT PUMPS
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS
550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION
More information10+ SEER - AIR CONDITIONER
10+ SEER AIR CONDITIONER 1 1 / 2 THRU 5 TONS SPLIT SYSTEM FEATURES Service valves on all models with 3 1 / 2 stubs External refrigerant connections Copper tube / aluminum fin coil Prepainted condenser
More information13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum
FORM NO. P66-774 Supersedes Form No. P66-765 Rev. 4 Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES earth friendly refrigerant 13 SEER HEAT PUMPS Features Coils constructed with copper tubing
More informationSPLIT SYSTEM COOLING 2, 3, 4 & 5 TON ALLEGIANCE 16 MODELS 4A7A6024,036,048 & 060B American Standard Inc. All Rights Reserved
SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON ALLEGIANCE 16 MODELS 4A7A6024,036,048 & 060B 2005 American Standard Inc. All Rights Reserved PUB. NO. 12-1200-02 March 2005 Features and Benefits Duration staged scroll
More informationSPLIT SYSTEM COOLING 2½, 3, 4 & 5 TON ALLEGIANCE 18 MODELS 2A7A8030, 036, 048 & 060B American Standard Inc. All Rights Reserved
SPLIT SYSTEM COOLING 2½, 3, 4 & 5 TON ALLEGIANCE 18 MODELS 2A7A8030, 036, 048 & 060B 2005 American Standard Inc. All Rights Reserved PUB. NO. 12-1194-02 February 2005 Features and Benefits Two Duration
More informationAFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton.
AFAIR12B Air Conditioners Features Top discharge directs hot air and noise away from the living area Durable Copeland scroll compressor with internal pressure relief valves and inherent thermal protection
More informationGQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY
TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged
More informationN4A6. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,
More informationGQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS GQ3RD Series Single Packaged Heat Pump, Single Phase GQ3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The GQ3 Series single packaged
More informationProduct Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )
13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation
More informationS6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.
TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed
More informationCSA6. Product Specifications. SoftSound SXC 2600
16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models
More informationQ7RE Series Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged
More informationSTELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING
(598) STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING HEAT PUMP S: F2RP / F2FP018 THRU 060 COOLING S: F2RC / F2FC018 THRU 036 VARIABLE SPEED : F2FV060 DESCRIPTION This fan coil
More informationBosch BOVA Split System Heat Pump
Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 03.2018 Bosch Thermotechnology
More informationNXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER
ENVIRONMENTALLY SOUND REFRIGERANT NXA6 Performance Series Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More informationDESCRIPTION FEATURES
SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at
More informationHEAT PUMPS UPKB- SERIES. Seven Models
FORM NO. P22-754 REV. 1 Supersedes Form No. P11-729 Rev. 8 HEAT PUMPS UPKB- SERIES Seven Models 10 SEER with efficiencies ranging up to 10.30 SEER in certain matched systems. Nominal Sizes 1 1 /2 to 5
More informationCOMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER
ENVIRONMENTALLY SOUND REFRIGERANT COMMERCIAL H4A3 DX 1300 Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More information10AC DIPLOMAT SERIES RFC SYSTEMS
10AC DIPLOMAT SERIES CONDENSING UNITS RFC SYSTEMS 10.05 to 10.55 SEER *11,100 to 60,000 Btuh (3.3 to 17.6 ) 1 thru 5 Tons (3.5 to 17.6 ) *ARI and DOE Certified Ratings CONDENSING ENGINEERING UNITS DATA
More informationProduct Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:
15SEERSplitHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial
More informationPHR5. Product Specifications
PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R
More informationTSA6. Product Specifications. SmartComfort TXC 5600
ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230
More information