TECHNICAL GUIDE LISTED

Size: px
Start display at page:

Download "TECHNICAL GUIDE LISTED"

Transcription

1 P G TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 10 SEER MODELS: HP018X10* THRU 060X10* (1.5 THRU 5 NOMINAL TONS) HP036X10* THRU 060X10* (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at for the most up-to-date technical information. Additional rating information can be found at U R MA N U F A CT R E C E CE R T I F R T I UN I TA RY A R I F I I E D C A T E QU I S T A I O T O R P ME N A R S N N D A R T I AS E CT D H E AT C P U M I ON S OM P O F L Y N I Rev. A (0106) DESCRIPTION The 10 SEER Series heat pumps is the outdoor part of a versatile system of heat pumps. It is designed to be custommatched with one of UPG s complete line of evaporator sections, with each serving a specific function. Matching Air Handlers are available for upflow, downflow, or horizontal applications to provide a complete system. Electric Heaters are available, if required. Add-On coils are available for use with upflow, downflow, or horizontal furnaces and air handlers. WARRANTY 5-year limited parts warranty. 5-year limited compressor warranty. FEATURES QUALITY COILS - The coil is constructed of copper tube and aluminum fins. COIL PROTECTION - Coils are protected from damage by a polymer mesh applied between the coil face, and a PVC coated steel coil guard. PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor. DURABLE FINISH - Cabinet is made of pre-painted steel. The pre-treated flat galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and matted-textured finish insure less fading when exposed to sunlight. LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. Discharge line heat exchanger knockouts are provided, if required. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof. TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. LOW MAINTENANCE - Long life permanently lubricated motor-bearings need no annual servicing. EASY SERVICE ACCESS - Fully exposed refrigerant connections, a single panel covering the electrical controls, and the molex plug in the control box connecting the condenser fan make for easy servicing of the unit. SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging. U.L. and C.U.L. listed - approved for outdoor application. Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

2 Physical and Electrical Data - 1 Phase MODEL HP018X1021 HP024X1021 HP030X1021 HP036X1021 HP042X1021 HP048X1022 HP060X1021 Unit Supply Voltage 208/ Normal Voltage Range to 252 Minimum Circuit Ampacity Max. Overcurrent Device Amps Compressor Type 3 Recip Recip Recip Recip Recip Scroll B Scroll C Compressor Rated Load Amps Locked Rotor Crankcase Heater Yes Yes Yes Yes Yes No No Fan Motor Amps Rated Load Fan Diameter Inches Fan Motor Rated HP 1/12 1/12 1/4 1/4 1/4 1/4 1/4 Nominal RPM 1,100 1,100 1,100 1, Nominal CFM 1,850 1,850 2,750 2,750 3,150 3,350 3,350 Face Area Sq. Ft Coil Rows Deep Fin / Inches Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed) 3/4 3/4 3/4 3/4 3/4 7/8 7/8 Unit Charge (Lbs. - Oz.) Charge Per Foot, Oz Operating Weight Lbs Physical and Electrical Data - 3 Phase MODEL HP036X1031 HP048X1032 HP060X1031 HP036X1041 HP048X1042 HP060X1041 Unit Supply Voltage 208/ Normal Voltage Range to to 504 Minimum Circuit Ampacity Max. Qvercurrent Device Amps Compressor Type 3 Inertia Scroll B Scroll C Inertia Scroll B Scroll C Compressor Rated Load Amps Locked Rotor Crankcase Heater Yes No No Yes No No Fan Motor Amps Rated Load Fan Diameter Inches Fan Motor Rated HP 1/4 1/4 1/4 1/4 1/5 1/4 Nominal RPM 1, , Nominal CFM 2,750 3,500 3,100 2,750 3,500 3,100 Coil Face Area Sq. Ft Rows Deep Fin / Inches Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed) 3/4 7/8 7/8 3/4 7/8 7/8 Unit Charge (Lbs. - Oz.) Charge Per Foot, Oz Operating Weight Lbs Rated in accordance with ARI Standard 110, utilization range A. 2. Dual element fuses or HACR circuit breaker. 3. All scrolls listed with a superscript B are Bristol scrolls. All scrolls listed with a superscript C are Copeland scrolls. 4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. 2 Unitary Products Group

3 Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase Outdoor Unit HP018X1021 HP024X1021 HP030X1021 HP036X1021 HP042X1021 HP048X1022 HP060X1021 Unit Orifice (s) 1 51, 53 59, 61 67, , 78, 81 81, 84, Factory R-22 Charge, lbs-oz Indoor Coil Coil Orifice 2 System Orifice - Additional Charge, Oz G2FD024S(H) G2FD030S(H) G2FD035S(H) G2FD036S(H)17/ G2FD042S(H) G2FD046S(H) G2FD048S(H)21/ G2FD060S(H) G1HD G1HD G1HD G1HD G1FA/G1UA024S14/ G1FA/G1UA030S G1FA/G1UA036S G1FA/G1UA03617/ G1FA/G1UA048S21/ G1FA/G1UA060S G1NA030S17H G1NA030S21B G1NA036S17L G1NA048S21D G1NA048S24P G1NA060S24T G1NF024SOF G1NF036SOF G1NF048SOF G1NF060SOF F2RP/F2FP F2RP/F2FP F2RP/F2FP F2RP/F2FP F2RP/F2FP F2FP F2FP FOOTNOTES: 1. These orifices are packed in the customer packet of each outdoor unit. 2. These orifices are factory mounted in the flow control device of each indoor coil. 3. TXV kit must be used with these coils to obtain system performance. (701,702,703 indicates 1TV07...series). 4. Systems matched with furnaces or air handlers not equipped with blower-off delays, may require blower Time Delay Kit #6918A50112FD PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaportor and for 15 feet of interconnecting line tubing. 2. Verify the orifice size and additional charge required for specific evaportor coil in the system using the above table. 3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaportor + adder for line set. 5. If the orifice in the evaportor was changed, verify the evaportor nameplate has been marked with the correct orifice size. Unitary Products Group 3

4 Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase Outdoor Unit HP036X HP048X HP060X Unit Orifice (s) 1 71, 75 81, 84, Factory R-22 Charge, lbs-oz Indoor Coil Coil Orifice 2 System Orifice = Additional Charge, Oz G1NA036S17L G1NA048S21D G1NA048S24P G1UA048S G1UA060S G1FA048S G1FA060S G2FD042(S,H) G2FD048(S,H)21/ G2FD060(S,H) FOOTNOTES: 1. These orifices are packed in the instruction/warranty packet of each outdoor unit. 2. These orifices are factory mounted in the flow control device of each indoor coil. 3. A TXV kit must be used with these coils to obtain system performance. (701,702,703 indicates 1TV Series). PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaportor and for 15 feet of interconnecting line tubing. 2. Verify the orifice size and additional charge required for specific evaportor coil in the system using the above table. 3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaportor + adder for line set. 5. If the orifice in the evaportor was changed, verify the evaportor nameplate has been marked with the correct orifice size. 4 Unitary Products Group

5 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING UNIT MODEL COIL 1 MODEL ELECTRIC 2 RATED NET MBH SEER SEER W MODEL HEAT KW CFM TOTAL SENS. W/O TXV WITH TXV 3 EER 1 PH 10 SEER HP WITH N1AH / G2FD HP018X1021 N1AHB0806 2,5,8,10 17 G2FD024(S,H) HP024X1021 N1AHB0806 2,5,8,10 17 G2FD030(S,H) HP030X1021 N1AHB1206 5,8,10,15,19 17 G2FD030(S,H) HP036X1021 N1AHB1206 5,8,10,15,19 17 G2FD036(S,H) HP042X1021 N1AHC1606 5,8,10,15,20 21 G2FD048(S,H) N1AHC1606 5,8,10,15,20 21 G2FD048(S,H) HP048X1022 N1AHD2006 8,10,15,20,25,30 24 G2FD048(S,H) N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H) HP060X1021 N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H) PH 10 SEER HP WITH N1AH / G2FD HP036X10(31,41) N1AHC ,15 21 G2FD042(S,H) N1AHC ,15 21 G2FD048(S,H) HP048X10(32,42) N1AHD ,15,29 24 G2FD048(S,H) HP060X10(31,41) N1AHD ,15,29 24 G2FD060(S,H) PH 10 SEER HP / F2RP / RC / FP / FC HP018X1021 HP024X1021 HP030X1021 HP036X1021 HP042X1021 F2RP/FP018 2,5, F2RP/FP024 5,8, F2RP/FP024 5,8, F2RP/FP030 5,8,10, F2RP/FP030 5,8,10, F2RP/FP036 5,8,10,15, F2RP/FP036 5,8,10,15, F2RP/FP042 5,8,10, F2RP/FP042 5,8,10, F2FP048 5,8,10,15,20, F2FP048 5,8,10,15,20, HP048X1022 F2FP060 5,8,10,15,20, HP060X1021 F2FP060 5,8,10,15,20, PH 10 SEER HP / F2RP / RC / FP / FC 4,5 HP036X10(31,41) F2RP/FP036 5,8,10,15, F2RP/FP042 5,8,10, F2FP048 5,8,10,15,20, HP048X10(32,42) F2FP060 5,8,10,15,20, HP060X10(31,41) F2FP060 5,8,10,15,20, Rated in accordance with DOE test procedures (Federal Register and ) and ARI Standards 210. Cooling MBH based on 80 F entering air temperature, 50% RH, and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTU s at a 95 F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2. Single phase units require single phase 2HK heaters. 3. TXV = Use 1TV700 Series Kit. 4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC. models. All ratings remain the same. 5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D. standard. - = Not applicable Unitary Products Group 5

6 COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils FURNACE** COIL UNIT MODEL NET MBH W MODEL HP018X1021 HP024X1021 HP030X1021 HP036X1021 HP036X10(31,41) For Notes see Page 5. CFM RANGE (MIN.-MAX.) RATED CFM TOTAL SENS. COOLING SEER\\ W/O TXV SEER + TXV 1 14,17 G1FA024S14, G1FA030S G1HA024H G1HD G1NA030S17H G1NA030S21B ,17 G1UA024S14, G1UA030S ,17 G2FD024(S,H)14, G1FA030S ,21 G1FA036S17, G1HA024H G1HA036H G1HD G1NA030S17H G1NA030S21B G1UA030S ,21 G1UA036S17, ,17 G2FD024(S,H)14, G2FD030(S,H) G2FD035(S,H) G1FA036S ,21 G1FA036S17, G1HA036H G1HA036H G1HD G1NA030S17H G1NA030S21B G1UA036S ,21 G1UA036S17, G2FD030(S,H) G2FD035(S,H) G2FD036(S,H) G2FD036(S,H) ,24 G1FA048S G1HA036H G1HA036H G1HA048H G1HD G1HD G1NA036S17L G1NA048S21D ,24 G1UA048S G2FD036(S,H) G2FD036(S,H) G2FD042(S,H) G2FD046(S,H) ,24 G1FA048S G1NA036S17L G1NA048S21D ,24 G1UA048S G2FD042(S,H) EER 6 Unitary Products Group

7 COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils (Continued) FURNACE** COOLING COIL UNIT MODEL NET MBH W MODEL EER HP042X1021 HP048X1022 HP048X10(32,42) HP060X1021 HP060X10(31,41) CFM RANGE (MIN.-MAX.) RATED CFM 21,24 G1FA048S G1HA036H * G1HA036H17T * G1HA048H G1HD G1NA048S21D ,24 G1UA048S G2FD042(S,H) G2FD046(S,H) ,24 G2FD048(S,H)21, G2FD060(S,H) ,24 G1FA048S ,24 G1FA060S21, G1HA048H G1HA060H G1HD G1HD G1NA048S21D ,24 G1UA048S ,24 G1UA060S21, ,24 G2FD048(S,H)21, G2FD060(S,H) ,24 G1FA048S G1NA048S21D ,24 G1UA048S ,24 G2FD048(S,H)21, ,24 G1FA060S21, G1HA060H24T * G1HD G1NA060S24T ,24 G1UA060S21, G2FD060(S,H) ,24 G1FA060S21, ,24 G1UA060S21, G2FD060(S,H) TXV = Use 1TV700 Series Kit. * Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. TOTAL SENS. SEER\\ W/O TXV SEER + TXV 1 Unitary Products Group 7

8 HEATING PERFORMANCE - With Air Handler UNIT MODEL* HP018X1021 HP024X1021 HP030X1021 COIL 1 MODEL ARI HEATING 2 OUTDOOR TEMP 3 47 F 17 F HSPF -3 F 7 F 17 F 27 F 37 F 47 F 57 F MBH COP MBH COP STD MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW F2RP/F2FP F2RP/F2FP F2RP/F2FP F2RP/F2FP F2RP/F2FP F2RP/F2FP F2RP/F2FP HP036X1021 F2RP/F2FP HP036X10(31,41) F2RP/F2FP HP042X1021 F2RP/F2FP F2FP HP048X1022 F2FP F2FP HP048X10(32,42) F2FP HP060X1021 F2FP HP060X10(31,41) F2FP Rated CFM same as for cooling. 2. Heating MBH based on ARI standards of 70 DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation. 3. Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur. COP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. = Not Applicable. HEATING PERFORMANCE - With Furnace Coils UNIT MODEL* HP018X1021 HP024X1021 HP030X1021 COIL 1 MODEL ARI HEATING 2 OUTDOOR TEMP 3 47 F 17 F HSPF -3 F 7 F 17 F 27 F 37 F 47 F 57 F MBH COP MBH COP STD MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW G2FD024(S,H)14, G1HD G1NA030S17H G1NA030S21B G1UA024S14, G1FA024S14, G2FD035(S,H) G2FD030(S,H) G2FD024(S,H)14, G1HD G1NA030S17H G1NA030S21B G1UA030S G1UA036S17, G1FA030S G1FA036S17, G2FD030(S,H)14, G2FD035(S,H) G2FD036(S,H) G2FD036(S,H) G1HD G1NA030S17H G1NA030S21B G1UA G1UA036S17, Unitary Products Group

9 HEATING PERFORMANCE - With Furnace Coils (Continued) UNIT MODEL* HP036X1021 HP036X10(31, 41) HP042X1021 HP048X1022 HP048X10(32, 42) G2FD036(S,H) G2FD036(S,H) G2FD042(S,H) G2FD046(S,H) G1HD G1HD G1NA036S17L G1NA048S21D G1UA048S G1FA048S G2FD042(S,H) G1NA036S17L G1NA048S21D G1UA048S G1FA048S G2FD042(S,H) G2FD046(S,H) G2FD048(S,H)21, G1HD G1NA048S21D G1NA048S24P G1UA048S G1FA048S G2FD048(S,H)21, G2FD060(S,H) G1HD G1HD G1NA048S21D G1NA048S24P G1UA048S G1UA060S21, G1FA048S G1FA060S21, G2FD048(S,H)21, G1NA048S21D G1UA048S G1FA048S For Notes see Page 7. G2FD060(S,H) G1HD HP060X1021 G1NA060S24T G1UA060S21, G1FA060S21, HP060X10(31, 41) COIL 1 MODEL ARI HEATING 2 OUTDOOR TEMP 3 47 F 17 F HSPF -3 F 7 F 17 F 27 F 37 F 47 F 57 F MBH COP MBH COP STD MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW G2FD060(S,H) G1UA060S G1FA060S Rated CFM same as for cooling. 2. Heating MBH based on ARI standards of 70 DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation. 3. Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur. COP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. = Not Applicable. Unitary Products Group 9

10 ACCESSORIES Refer to Price Manual for specific model numbers. Start Assist Kit (2SA067*) Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied. Hard Start Kits - Provides required starting torque for use with Thermal Expansion Valve Kit. Low Temperature Cutout (2LT ) - Prevents heat pump operation below -10 F ambient temperature. Compressor Blanket - Designed to further reduce the normal operating sound. Add-on Fossil Fuel Control - Interface controls for use with gas, oil furnaces and the heat pump system are available. Thermal Expansion Valve Kit - 1TV0700 Series TXV kit used to improve system performance. Outdoor Thermostat (2TD ) - Provides additional staging of supplemental electric heat. Room Thermostats - A wide selection of matching thermostats is available to provide features required for any installation. 2H/1C, manual change-over electronic non-programmable thermostat. 3H/2C, non-programmable digital thermostat. 3H/2C, auto/manual changeover, electronic programmable, 7-day, hardwire thermostat. * For the most current accessory information, refer to the price book or consult factroy. SOUND RATINGS* UNIT MODEL SOUND RATINGS DECIBELS *Rated in accordance with ARI Standard 270. A All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request DIMENSIONS - 1 PHASE Unit Model Dimensions (Inches) Refrigerant Connection Service Valve Size A 1 B C Liquid Vapor / / /8 1. Including fan guard. DIMENSIONS - 3 PHASE Unit Model Dimensions (Inches) Refrigerant Connection Service Valve Size A 1 B C Liquid Vapor / /8 7/ /8 1. Including fan guard. B C TYPICAL INSTALLATION 60 OVERHEAD CLEARANCE 10 CLEARANCE COIL AREA MINIMUM 18 SERVICE ACCESS CLEARANCE ON ONE SIDE WEATHERPROOF DISCONNECT SWITCH THERMOSTAT TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING NEC CLASS 2 WIRING TO INDOOR COIL NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF. SEAL OPENING(S) WITH PERMAGUM OR EQUIVALENT CONTROL ACCESS PANEL 10 Unitary Products Group

11 TYPICAL FIELD WIRING - 1 PH ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES R BorC Y O W LorX G T 2 E 2 THERMOSTAT INDOOR UNIT OUTDOOR UNIT 1 FIELD INSTALLED JUMPER 1 JUMPER TERMINALS E AND W TOHEAT ON FIRST STAGE DURING EMERGENCY HEAT. 2 TERMINAL NOT USED ON ALL THERMOSTATS. POWER WIRING 24V CONTROL WIRING (NEC CLASS 2) LOW VOLTAGE TERMINAL BLOCK 3,4 DEFROST IN AIR HANDLER WITH ELECTRIC HEAT CONTROL R RED R C BLK C Y YEL Y O ORG O W2 BRN W PUR X/L G WHT W1/66 W1 5GRY CC BK DEHUMIDIFICATION CONTROL CONNECTION (Humidistat* Jumper must be removed) GND. LUG CIRCUIT BREAKER*** CONTACTOR T2 L2 M T1 L1 POWER WIRING 208/ GND. SCREW 3 CHECK THE LOW VOLTAGE TERMINAL BLOCK ON THE INDOOR UNIT FOR THE ACTUAL ARRANGEMENT OF THE TERMINALS. 4 CONNECT POWER WIRING TO TERMINAL BLOCK 3TB ON UNITS WITHOUT ELECTRIC HEAT OR CIRCUIT BREAKER. 5 GRAY FOR USE WITH OPTIONAL OUTDOOR THERMOSTAT KITS. TYPICAL FIELD WIRING - 3 PH ( ) ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES R BorC Y O W X G T 2 E 2 THERMOSTAT INDOOR UNIT OUTDOOR UNIT 1 FIELD INSTALLED JUMPER 1 JUMPER TERMINALS E AND W TOHEAT ON FIRST STAGE DURING EMERGENCY HEAT. 2 TERMINAL NOT USED ON ALL THERMOSTATS. 3 TERMINAL NOT USED ON ALL THERMOSTATS. POWER WIRING 24V CONTROL WIRING (NEC CLASS 2) GND. LUG 3,4 LOW VOLTAGE TERMINAL BLOCK IN AIR HANDLER WITH ELECTRIC HEAT R C Y O W X 53 G DEFROST CONTROL RED R BLK C YEL Y ORG O BRN W PUR X WHT W1/66 POWER SUPPLY 208/ CONTACTOR T2 M L2 T1 L1 POWER WIRING 208/ GND. SCREW 3 CHECK THE LOW VOLTAGE TERMINAL BLOCK ON THE INDOOR UNIT FOR THE ACTUAL ARRANGEMENT OF THE TERMINALS. 4 CONNECT POWER WIRING TO TERMINAL BLOCK 3TB ON UNITS WITHOUT ELECTRIC HEAT OR CIRCUIT BREAKER. 5 REQUIRED ON ALL ELECTRIC HEAT 5 FIELD INSTALLED JUMPER T3 L3 Unitary Products Group 11

12 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. HP018X1021 INDOOR COIL MODEL NO. F2RP/F2FP018 CONDENSER ID CFM AIR ID DB ( F) TEMPERATURE ID WB ( F) T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW Multipliers for determining the perfomrance with other indoor sections. Air Handler Coil T.C. S.C. KW N1AHB0806 G2FD024S F2RP/F2FP G1FA024S14, G1FA030S G1HD G1NA030S17H G1NA030S21B G1UA024S14, G1UA030S G2FD024S14, Unitary Products Group

13 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. HP024X1021 INDOOR COIL MODEL NO. F2RP/F2FP030 CONDENSER ID CFM AIR ID DB ( F) TEMPERATUR ID WB ( F) T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW Multipliers for determining the perfomrance with other indoor sections. Air Handler Coil T.C. S.C. KW N1AHB0806 G2FD030S F2RP/F2FP G1FA030S G1FA036S17, G1HD G1NA030S17H G1NA030S21B G1UA030S G1UA036S17, G2FD024S14, G2FD030S G2FD035S Unitary Products Group 13

14 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. HP030X1021 INDOOR COIL MODEL NO. F2RP/F2FP036 CONDENSER ID CFM AIR ID DB ( F) TEMPERATURE ID WB ( F) T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW Multipliers for determining the perfomrance with other indoor sections. Air Handler Coil T.C. S.C. KW N1AHB1206 G2FD030S F2RP/F2FP G1FA036S G1FA036S17, G1HD G1NA030S17H G1NA030S21B G1UA036S G1UA036S17, G2FD030S G2FD035S G2FD036S G2FD036S Unitary Products Group

15 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. HP036X1021, HP036X10(31,41) INDOOR COIL MODEL NO. F2RP/F2FP036 CONDENSER ID CFM AIR ID DB ( F) TEMPERATURE ID WB ( F) T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW Multipliers for determining the perfomrance with other indoor sections. 1 Phase 3 Phase Air Handler Coil T.C. S.C. KW Air Handler Coil T.C. S.C. KW N1AHB1206 G2FD036S N1AHC1646 G2FD042S F2RP/F2FP F2RP/F2FP G1FA048S G1FA048S G1HD G1NA036S17L G1HD G1NA048S21D G1NA036S17L G1UA048S G1NA048S21D G2FD042S G1UA048S G2FD036S G2FD036S G2FD042S G2FD046S Unitary Products Group 15

16 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. HP042X1021 INDOOR COIL MODEL NO. F2RP/F2FP042 CONDENSER ID CFM AIR ID DB ( F) TEMPERATURE ID WB ( F) T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW Multipliers for determining the perfomrance with other indoor sections. Air Handler Coil T.C. S.C. KW N1AHC1606 G2FD048S F2FP G1FA048S G1HD G1NA048S21D G1UA048S G2FD042S G2FD046S G2FD048S21, G2FD060S Unitary Products Group

17 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. HP048X1022, HP048X10(32,42) INDOOR COIL MODEL NO. F2FP048 CONDENSER ID CFM AIR ID DB ( F) TEMPERATURE ID WB ( F) T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW Multipliers for determining the perfomrance with other indoor sections. 1 Phase 3 Phase Air Handler Coil T.C. S.C. KW Air Handler Coil T.C. S.C. KW N1AHC1606 G2FD048S N1AHC1646 G2FD048S N1AHD2006 G2FD048S N1AHD2046 G2FD048S N1AHD2006 G2FD060S F2FP F2FP G1FA048S G1FA048S G1NA048S21D G1FA060S21, G1UA048S G1HD G2FD048S21, G1HD G1NA048S21D G1UA048S G1UA060S21, G2FD048S21, G2FD060S Unitary Products Group 17

18 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. HP060X1021 INDOOR COIL MODEL NO. F2FP060 CONDENSER ID CFM AIR ID DB ( F) TEMPERATURE ID WB ( F) T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW Multipliers for determining the perfomrance with other indoor sections. Air Handler Coil T.C. S.C. KW N1AHD2006 G2FD060S G1FA060S21, G1HD G1NA060S24T G1UA060S21, G2FD060S Unitary Products Group

19 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. HP060X10(31,41) INDOOR COIL MODEL NO. G2FD060S24 CONDENSER ID CFM AIR ID DB ( F) TEMPERATURE ID WB ( F) T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW T.C S.C KW Multipliers for determining the performance with other indoor sections. Air Handler Coil T.C. S.C. KW N1AHD2046 G2FD060S F2FP060 G1FA060S21, G1FA060S21, G1UA060S21, Unitary Products Group 19

20 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO. EVAPORATOR COIL MODEL NO. OUTDOOR UNIT INDOOR COIL HP018X1021 F2RP/F2FP018 Multipliers for determining the performance with other indoor sections. ID CFM MBTUH K.W C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P Air Handler Coil MBH KW COP N1AHB0806 G2FD024S14, F2RP/F2FP G2FD024S14, G1HD G1NA030S17H G1NA030S21B G1UA024S14, G1FA024S14, G1UA030S G1FA030S Unitary Products Group

21 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO. EVAPORATOR COIL MODEL NO. OUTDOOR UNIT INDOOR COIL HP024X1021 F2RP/F2FP030 Multipliers for determining the performance with other indoor sections. ID CFM MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P Air Handler Coil MBH KW COP N1AHB0806 G2FD030S F2FP G2FD035S G2FD030S G2FD024S14, G1HD G1NA030S17H G1NA030S21B G1UA030S G1UA036S17, G1FA030S G1FA036S17, Unitary Products Group 21

TECHNICAL GUIDE DESCRIPTION

TECHNICAL GUIDE DESCRIPTION TECHNICAL GUE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER S: BRCS018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) H*BA-(T,W)036 THRU 090 (3 THRU 7.5 NOMINAL TONS, 3 PH) S: 018-060 (1 PH & 3 PH) S: 076-090 (3 PH)

More information

TECHNICAL GUIDE LISTED

TECHNICAL GUIDE LISTED T I I I T G TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER MODELS: H*BA018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) H*BA036(25,46) THRU 090 (3 THRU 7.5 NOMINAL TONS, 3 PH) This product was manufactured

More information

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: AC018X12* THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH)

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: AC018X12* THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) E T I I I R P I T G TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: AC018X12* THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) LISTED ISO 9001 Certified Quality Management System CERTIFICATION APPLIES

More information

TECHNICAL GUIDE LISTED

TECHNICAL GUIDE LISTED E T I I I R P I T G TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: H*BC-F018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH)H*BC- (T,W)036 THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001

More information

LISTED TECHNICAL GUIDE STELLAR 2000 TM

LISTED TECHNICAL GUIDE STELLAR 2000 TM E T I I I R P I T I O I N G TECHNICAL GUIDE STELLAR 2000 TM SPLIT-SYSTEM AIR CONDITIONERS 10 SEER S: H*DB018 THRU 060 (1 THRU 5 NOMINAL TONS, 1 PH) H*DB036 THRU 076 (3 THRU 6-1/3 NOMINAL TONS, 3 PH) This

More information

SPLIT SYSTEM HEAT PUMPS. ERA Series 10 SEER Single and Three Phase TECHNICAL SPECIFICATIONS

SPLIT SYSTEM HEAT PUMPS. ERA Series 10 SEER Single and Three Phase TECHNICAL SPECIFICATIONS 515.16-TG1Y (499) TECHNICAL SPECIFICATIONS SPLIT SYSTEM HEAT PUMPS Models 018-060 1Ø 036, 048 3Ø ERA Series 10 SEER Single and Three Phase Models ERA 018 thru ERA090 Nominal Capacity: 18 thru 90 MBH Models

More information

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS) TECHNICAL GUIDE TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE S: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS) LISTED Due to continuous product improvement, specifications are subject

More information

TECHNICAL GUIDE LISTED SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE)

TECHNICAL GUIDE LISTED SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE) TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE) LISTED ISO 9001 Certified Quality Management System Due to continuous product improvement,

More information

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60 TECHNICAL GUIDE GUARDIAN SERIES DRY SHIP AIR CONDITIONER CONDENSING UNITS SHIPPED WITH NITROGEN CHARGE ONLY 13 SEER R-22 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: GCGD18 THRU 60 UARDIAN Due to continuous

More information

LISTED TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A MODELS: THJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A MODELS: THJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES DESCRIPTION 560550-CTG-A-0310 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES P G 036-21342-002 Rev. C (0902) TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) U R MA N U F A CT R E C E CE R T I F R T I UN I TA RY A R I F I

More information

TECHNICAL GUIDE MODELS: RHP14J18 THRU 60 RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: RHP14J18 THRU 60 RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES TECHNICAL GUIDE RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RHP14J18 THRU 60 Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE MODELS: RHP13J30 THRU 60 (3 ) RHP SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS.

TECHNICAL GUIDE MODELS: RHP13J30 THRU 60 (3 ) RHP SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS. TECHNICAL GUIDE RHP SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS S: RHP13J30 THRU 60 (3 ) Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE 16 SEER 2-5 TON AIR CONDITIONING SPLIT-SYSTEM COOLING H4TS024 H4TS030 H4TS036 H4TS048 H4TS060 DESCRIPTION FEATURES MODELS:

TECHNICAL GUIDE 16 SEER 2-5 TON AIR CONDITIONING SPLIT-SYSTEM COOLING H4TS024 H4TS030 H4TS036 H4TS048 H4TS060 DESCRIPTION FEATURES MODELS: 036-21023-002 Rev A (5/00) TECHNICAL GUIDE 16 SEER 2-5 TON CONDITIONING SPLIT-SYSTEM COOLING DESCRIPTION The HTS Stealth series condensing units use Twin Single compressor technology to provide cooling

More information

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 MODELS: GCGD12 THRU 60 (1 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 MODELS: GCGD12 THRU 60 (1 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 S: GCGD12 THRU 60 (1 THRU 5 NOMINAL TONS, 1 PHASE) LISTED Due to continuous product improvement, specifications are subject to change without

More information

Advance Information SPLIT SYSTEM HEAT PUMP 10 SEER. ERA 018 thru thru 5 NOMINAL TONS DESCRIPTION FEATURES

Advance Information SPLIT SYSTEM HEAT PUMP 10 SEER. ERA 018 thru thru 5 NOMINAL TONS DESCRIPTION FEATURES 515.16-TG1Y (1095) Advance Information SPLIT SYSTEM HEAT PUMP 10 S ERA 018 thru 060 1.5 thru 5 NOMINAL TONS DESCRIPTION The ERA series heat pumps are designed for use with a variety of YORK evaporator

More information

LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE MODELS: YCJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE MODELS: YCJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES DESCRIPTION 364834-YTG-H-0509 The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS TECHNICAL GUIDE RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RAC13J18 THRU 60 Due to continuous product improvement, specifications are subject to change without

More information

LISTED TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: YHJR18-60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: YHJR18-60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A S: YHJR18-60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) LISTED Due to continuous product improvement, specifications are subject to change without

More information

LISTED TECHNICAL GUIDE AFFINITY R-410A SPLIT-SYSTEM AIR CONDITIONERS UP TO 18 SEER MODELS: CZE024 THRU 060 (2 THRU 5 NOMINAL TONS)

LISTED TECHNICAL GUIDE AFFINITY R-410A SPLIT-SYSTEM AIR CONDITIONERS UP TO 18 SEER MODELS: CZE024 THRU 060 (2 THRU 5 NOMINAL TONS) E T I I I R P I T G 036-21592-002 Rev. A (1204) TECHNICAL GUIDE AFFINITY R-410A SPLIT-SYSTEM AIR CONDITIONERS UP TO 18 SEER MODELS: CZE024 THRU 060 (2 THRU 5 NOMINAL TONS) U R A C T MA N U F R C E UN I

More information

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A Single Phase MODELS: YHJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A Single Phase MODELS: YHJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY DESCRIPTION 561923-YTG-C-1211 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES SEER. MODELS E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES SEER. MODELS E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES (1295) STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES - 12.00 SEER S E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION These high efficiency EFH Series heat pump units are the outdoor

More information

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A Single Phase MODELS: YHJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A Single Phase MODELS: YHJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY DESCRIPTION 571209-YTG-B-1211 The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

LISTED TECHNICAL GUIDE HORIZONTAL DISCHARGE AIR CONDITIONERS 13 SEER R-410A MODELS: YCHD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE)

LISTED TECHNICAL GUIDE HORIZONTAL DISCHARGE AIR CONDITIONERS 13 SEER R-410A MODELS: YCHD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) TECHNICAL GUIDE HORIZONTAL DISCHARGE AIR CONDITIONERS 13 SEER R-410A MODELS: YCHD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS TECHNICAL GUIDE RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RAC13J18 THRU 60 Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE MODELS: RAC14J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION

TECHNICAL GUIDE MODELS: RAC14J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION TECHNICAL GUIDE RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RAC14J18 THRU 60 Due to continuous product improvement, specifications are subject to change

More information

SPLIT SYSTEM HEAT PUMP 12 SEER

SPLIT SYSTEM HEAT PUMP 12 SEER 515.18-TG1C (600) SPLIT SYSTEM HEAT PUMP 12 SEER 018 thru 060 1.5 thru 5 NOMINAL TONS GENERAL DESCRIPTION The series heat pumps are designed for use with a variety of UPG evaporator sections to suit any

More information

LISTED TECHNICAL GUIDE

LISTED TECHNICAL GUIDE TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 13 SEER R-22 MODELS: E*RD018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) E*RD030 THRU 060 (2.5 THRU 5 NOMINAL TONS, 3 PHASE) LISTED ISO 9001 Certified Quality Management

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A MODELS: TCJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A MODELS: TCJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES DESCRIPTION 700696-CTG-A-0312 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS DESCRIPTION

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS DESCRIPTION 571209-YTG-F-0615 DESCRIPTION The 14 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE MODELS: THJD30 THRU 60 (3 ) LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS.

TECHNICAL GUIDE MODELS: THJD30 THRU 60 (3 ) LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS. TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS S: THJD30 THRU 60 (3 ) Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE MODELS: THJD18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: THJD18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES DESCRIPTION 571471-LTG-C-1012 The 13 SEER Series unit is the outdoor part of a versatile climate system. It i76s designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806 TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS HEAT PUMP MODELS: F2RP/F2FP018 THRU 060 F3RP/F3FP018 THRU 060(T) FXRP024 THRU 060 COOLING MODELS F2RC/F2FC024 THRU

More information

TECHNICAL GUIDE MODELS: TCJD30 THRU 76 LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.3 NOMINAL TONS

TECHNICAL GUIDE MODELS: TCJD30 THRU 76 LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.3 NOMINAL TONS DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

TECHNICAL GUIDE LISTED

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 MODELS: H*BD-F018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) H*BD-(T,W)036 THRU 060 (2.5 THRU 5 NOMINAL TONS, 3 PHASE) LISTED Due to continuous

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE (1.5 THRU 5 NOMINAL TONS)

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE (1.5 THRU 5 NOMINAL TONS) DESCRIPTION 840621-LTG-A-0612 The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: GHD, GFD, GFA, GNA, GUA & GHA CFM 2-5 TON COILS

TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: GHD, GFD, GFA, GNA, GUA & GHA CFM 2-5 TON COILS Heating TECHNICAL GUIDE Air Conditioning ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: GHD, GFD, GFA, GNA, GUA & GHA 600-2000 CFM 2-5 TON COILS R DESCRIPTION These cooling and heat

More information

LISTED TECHNICAL GUIDE AFFINITY SPLIT-SYSTEM AIR CONDITIONERS 16 SEER R-410A MODELS: CZF024 THRU 060 (2 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE AFFINITY SPLIT-SYSTEM AIR CONDITIONERS 16 SEER R-410A MODELS: CZF024 THRU 060 (2 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES DESCRIPTION 567175-YTG-C-1010 The 16 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6. DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6. DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

TECHNICAL GUIDE MODELS: YHJR18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: YHJR18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER - R-410A - 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: THJD18 THRU 60

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER - R-410A - 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: THJD18 THRU 60 Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER - R-410A - 1 PHASE 1.5 THRU 5 NOMINAL TONS S: THJD18 THRU 60 Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE MODELS: YCJF18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: YCJF18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES DESCRIPTION 700695-YTG-C-0714 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections

More information

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING (598) STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING HEAT PUMP S: F2RP / F2FP018 THRU 060 COOLING S: F2RC / F2FC018 THRU 036 VARIABLE SPEED : F2FV060 DESCRIPTION This fan coil

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS.   DESCRIPTION FEATURE TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS.     DESCRIPTION TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER AY012MA THRU 030 (1 THRU 2.5 NOMINAL TONS, 1 PH)

LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER AY012MA THRU 030 (1 THRU 2.5 NOMINAL TONS, 1 PH) T R P T O N G 259800-YTG-B-0607 SPLT-SYSTEM AR CONDTONERS 13 SEER AY012MA THRU 030 (1 THRU 2.5 NOMNAL TONS, 1 PH) U R A C T MA N U F R E C E UN R T C ER T A R A RY F F E D E Q U C A T T S A T ON O M E

More information

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS TECHNICAL GUIDE AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: YZF024 THRU 060 Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS TECHNICAL GUIDE AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: YZF024 THRU 060 Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable

More information

TECHNICAL GUIDE HORIZONTAL DISCHARGE SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: TCHD18 THRU 60

TECHNICAL GUIDE HORIZONTAL DISCHARGE SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: TCHD18 THRU 60 TECHNICAL GUIDE HORIZONTAL DISCHARGE SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: TCHD18 THRU 60 Due to continuous product improvement, specifications are subject to

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES TECHNICAL GUIDE MODELS: N*AH Modular Air Handlers For use w / Split System Cooling & Heat Pump 600-2000 CFM Blowers 2-5 Ton Coils Optional 1 & 3 Electric Heaters DESCRIPTION This unique modular system

More information

TECHNICAL GUIDE MODELS: AC8B024 THRU 060* ECHELONTM SERIES SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS DESCRIPTION

TECHNICAL GUIDE MODELS: AC8B024 THRU 060* ECHELONTM SERIES SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS DESCRIPTION 1109218-CTG-B-0515 DESCRIPTION The 18 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from. Available for typical applications this

More information

TECHNICAL GUIDE MODELS: CZH024 THRU 060* SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS AFFINITYTM SERIES DESCRIPTION

TECHNICAL GUIDE MODELS: CZH024 THRU 060* SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS AFFINITYTM SERIES DESCRIPTION 1109217-YTG-B-0515 DESCRIPTION The 18 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from. Available for typical applications this

More information

10+ SEER - AIR CONDITIONER

10+ SEER - AIR CONDITIONER 10+ SEER AIR CONDITIONER 1 1 / 2 THRU 5 TONS SPLIT SYSTEM FEATURES Service valves on all models with 3 1 / 2 stubs External refrigerant connections Copper tube / aluminum fin coil Prepainted condenser

More information

10+ SEER - AIR CONDITIONER

10+ SEER - AIR CONDITIONER 10+ SEER AIR CONDITIONER 1 1 / 2 THRU 5 TONS SPLIT SYSTEM FEATURES Service valves on all models with 3 1 / 2 stubs External refrigerant connections Copper tube / aluminum fin coil Prepainted condenser

More information

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum FORM NO. P66-774 Supersedes Form No. P66-765 Rev. 4 Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES earth friendly refrigerant 13 SEER HEAT PUMPS Features Coils constructed with copper tubing

More information

TECHNICAL GUIDE AFFINITY TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: CZF024 THRU 060

TECHNICAL GUIDE AFFINITY TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: CZF024 THRU 060 TECHNICAL GUIDE AFFINITY TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: CZF024 THRU 060 Due to continuous product improvement, specifications are subject to change

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES TEHNIAL GUIDE SINGLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLING & HEAT PUMPS MODELS: AHP18 THRU 60 AND SHP48 THRU 60 DESRIPTION This fan coil line offers the ultimate in application flexibility.

More information

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton.

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton. AFAIR12B Air Conditioners Features Top discharge directs hot air and noise away from the living area Durable Copeland scroll compressor with internal pressure relief valves and inherent thermal protection

More information

Product Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS DUCTED HEAT PUMP Sizes 018 To 060 1.5 To 5 Nominal Tons Product Data A08379 INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency S Sound S Levels as low as 71 dba Design Features S New aesthetics S Small

More information

14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES

14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES FORM NO. PTZ-781 Supersedes Form No. PTZ-781 Featuring New Industry Standard R-410A Refrigerant TZPL SERIES Manufactured for Thermal Zone Philadelphia, PA (IN CERTAIN MATCHED SYSTEMS) 14.5 SEER HEAT PUMPS

More information

Q5RD Series Single Packaged Heat Pump, Single Phase

Q5RD Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The Q5 Series single packaged

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities TECHNICAL SPECIFICATIONS FSH1BG Series Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities The iq Drive heat pump system features modulating compressor technology and variable

More information

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum FORM NO. PTZ-803 Supersedes Form No. PTZ-781 Featuring Industry Standard R-410A Refrigerant TZPL SERIES Efficiencies up to 14.5 SEER/12.00 EER/8.50 HSPF Nominal Sizes 1.5 to 5 Tons [5.28 kw] to [17.6 kw]

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information

HEAT PUMPS UPKB- SERIES. Seven Models

HEAT PUMPS UPKB- SERIES. Seven Models FORM NO. P22-754 REV. 1 Supersedes Form No. P11-729 Rev. 8 HEAT PUMPS UPKB- SERIES Seven Models 10 SEER with efficiencies ranging up to 10.30 SEER in certain matched systems. Nominal Sizes 1 1 /2 to 5

More information

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES: 15SEERSplitHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

FORM NO. PTZ-806 REV. 1 HEAT PUMPS

FORM NO. PTZ-806 REV. 1 HEAT PUMPS FORM NO. PTZ-806 REV. 1 TZPLS-14 SERIES Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured for Thermal

More information

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230

More information

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from

More information

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity TECHNICAL SPECIFICATIONS ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity ET4BE Series now offers the choice of a heat pump that uses a more efficient and environmentally

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

P5RF Series Single Packaged Air Conditioner Single Phase

P5RF Series Single Packaged Air Conditioner Single Phase TECHNICAL SPECIFICATIONS P5RF Series Single Packaged Air Conditioner Single Phase 15 SEER, 12 EER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P5 Series single packaged air conditioners

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON ALLEGIANCE 16 MODELS 4A7A6024,036,048 & 060B American Standard Inc. All Rights Reserved

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON ALLEGIANCE 16 MODELS 4A7A6024,036,048 & 060B American Standard Inc. All Rights Reserved SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON ALLEGIANCE 16 MODELS 4A7A6024,036,048 & 060B 2005 American Standard Inc. All Rights Reserved PUB. NO. 12-1200-02 March 2005 Features and Benefits Duration staged scroll

More information

SPLIT SYSTEM COOLING 2½, 3, 4 & 5 TON ALLEGIANCE 18 MODELS 2A7A8030, 036, 048 & 060B American Standard Inc. All Rights Reserved

SPLIT SYSTEM COOLING 2½, 3, 4 & 5 TON ALLEGIANCE 18 MODELS 2A7A8030, 036, 048 & 060B American Standard Inc. All Rights Reserved SPLIT SYSTEM COOLING 2½, 3, 4 & 5 TON ALLEGIANCE 18 MODELS 2A7A8030, 036, 048 & 060B 2005 American Standard Inc. All Rights Reserved PUB. NO. 12-1194-02 February 2005 Features and Benefits Two Duration

More information

ZHA/ZHB SERIES WARNING

ZHA/ZHB SERIES WARNING Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,

More information

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS GQ3RD Series Single Packaged Heat Pump, Single Phase GQ3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The GQ3 Series single packaged

More information

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS JT4BD Series R-410A High Efficiency Heat Pump 13 SEER Residential System 1.5 5 Ton Capacity The JT4BD Series now offers the choice of a heat pump that uses a more efficient and

More information

HP19 Bulletin No August 1994 Supersedes November 1993

HP19 Bulletin No August 1994 Supersedes November 1993 ENGINEERING DATA HP19 SERIES HEAT PUMP OUTDOOR UNITS 10.05 to 12.15 SEER *18,000 to 61,000 (5.3 to 17.9 ) *18,800 to 59,000 (5.5 to 17.3 ) *ARI Standard 210/240 certified Ratings HEAT PUMP OUTDOOR UNITS

More information

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS Q3RD Series Single Packaged Heat Pump, Single Phase Q3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The Q3 Series single packaged

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

10AC DIPLOMAT SERIES RFC SYSTEMS

10AC DIPLOMAT SERIES RFC SYSTEMS 10AC DIPLOMAT SERIES CONDENSING UNITS RFC SYSTEMS 10.05 to 10.55 SEER *11,100 to 60,000 Btuh (3.3 to 17.6 ) 1 thru 5 Tons (3.5 to 17.6 ) *ARI and DOE Certified Ratings CONDENSING ENGINEERING UNITS DATA

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

PHB SERIES 7-1/2 and 10 TON

PHB SERIES 7-1/2 and 10 TON PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

TECHNICAL GUIDE R-410A AFFINITY SERIES DEZ MODELS 2-5 TON 60 Hertz

TECHNICAL GUIDE R-410A AFFINITY SERIES DEZ MODELS 2-5 TON 60 Hertz TECHNICAL GUIDE R-410A AFFINITY SERIES MODELS 2-5 TON 60 Hertz Description These York Affinity packaged air conditioners are designed for outdoor installation. Only utility and duct connections are required

More information

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12. TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner P7RE 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency self