Company profile 4 Technical features 6 Standard specifications 7 The OLI vibrator range 8 Certifications 9 How to choose a motovibrator 10
|
|
- Stephanie Fitzgerald
- 6 years ago
- Views:
Transcription
1 NTR VRTORS Jamieson quipmen
2
3 ompany profile 4 Technical features 6 Standard specifications 7 The O vibrator range 8 ertifications 9 ow to choose a motovibrator 10 2 poles 12 4 poles 14 6 poles 16 8 poles 18 2 poles single phase 20 RO 22 V irect urrent 24 2 poles 26 4 poles 28 6 poles 30 8 poles 32 2 and 4 poles 34 6 and 8 poles 36 8 and 10 poles 38 ounting 40 ow to change vibration intensity 42
4 O is the world s top selling manufacturer of lectric and Pneumatic Vibrators. high level of customer service is guaranteed through 19 O Trading Subsidiaries, 36 local warehouses and 5 manufacturing plants worldwide. OUR 3 VSONS PROV TORS WT OPT SOUTONS OR RQURNTS NTR VRTORS OW S ONRT ONSOTON lectric motovibrators for vibrating equipments omprehensive range of electric and pneumatic vibrators to solve any problem of flowability nternal concrete vibrators and converters for reliable and efficient concrete compaction Jamieson quipmen
5 Originally specialising in immersion vibrators for concrete consolidation, O is now the worldwide leader in vibration technology, with a complete range of electric and pneumatic internal and external vibrators. y supplying competitive, high quality products for wide-ranging applications, O combines performance and reliability by adapting to the ever-changing market. strong believer in innovation, O is constantly striving to be ahead of the opposition. s a global player in industrial vibration technology, the key focus of O s business strategy is rapid stock delivery, any time, anywhere in the world. xcellent customer service is of pivotal importance: the company guarantees quick order processing and customers worldwide can enjoy access to the same high quality product and services. O has access to credible expertise when it comes to finding suitable solutions to customers requests. team of engineers specialised in designing efficient, reliable and safe solutions backed by a globally certified management. O provide their customers with state-ofthe-art equipment and the blueprint for the next generation of products is already in progress. Jamieson quipmen
6 World class materials lass insulation urable sealing Premium bearings Strong body design - designed Vacuum insulation analysis 3 quality check Optimised power/weight ratio S1 continuous duty service Optimized electric design PT thermistor 130 Specific grease retaining device Tropicalised standard P66 protection lass insulation asy mass adjustment Various voltages and frequencies available asy access to the terminal box ultiple eye-bolts Jamieson quipmen
7 RNG Specification Standard ncreased Safety xplosion-proof i-stroke illing Power supply Three-phase from 12V to 690V, 50z or 60z; Single phase 110V 60z and 220V 50z. Three-phase motors are designed for inverter application Three-phase from 230V to 460V, 50z or 60z Three-phase from 230V to 690V, 50z or 60z. ll motors are designed for inverter application from 20z to base frequency Time rating ontinuous duty (S1) Protection structure echanical protection P66 according to N earings all bearings from size RO to 50, roller bearings from size 60 to 110 all bearings from size 10 to 50, roller bearings from size 60 to 90 Roller bearings oating colour Polyester powder coating. Standard colour R 2009 nstallation and operating environment mbient temperature: -20 to +40. Up to +55 available on request mbient temperature: -20 to +40 or indoor and outdoor use mbient temperature: -20 to +40. Up to +55 available on request mbient temperature: -20 to +40 Standards supported onformity with uropean irective ow voltage 2006/95/ 2004/108/ achine directive 2006/42/ TX 94/9/ ass covers luminium. Steel for motors from size 60 to size 90. S 304 Stainless Steel for direct current motovibrators luminium. Steel for motors from size 60 to size 90 S 304 Stainless Steel Steel Windings 2, 4, 6 and 8 poles threephase asynchronous motor from size 10 to 110; 2 poles single phase from size 10 to 30 2, 4, 6 and 8 poles three-phase asynchronous motor 8 and 10 poles three-phase asynchronous motor lass insulating materials (155 ). Vacuum impregnated windings; PT thermistor 130 standard from size 60 langes Grey cast iron up to size 80, ductile cast iron from size 100 rame luminium up to size 50, ductile cast iron from size 60 Shaft ccentric masses Steel alloy highly resistant ompletely adjustable Jamieson quipmen
8 frame shaft rotor flange bearing fixed mass adjustable mass mass cover Providing centrifugal force up to 26,000 kgs and with multiple voltage options O s range of electric motovibrators covers several fields of application in every country as well as many different industrial sectors: from food to mining, from foundry to recycling and more. O s electric motovibrators are designed and manufactured using the latest technologies and premium quality materials and components. otor bodies, bearing flanges and shafts are designed and manufactured using first grade luminium alloy, cast iron and steel alloy to withstand heavy duty applications and guarantee safe operation in any condition. Vacuum impregnated windings and class insulating materials enhance reliability and durability. Top quality bearings and an efficient grease retaining system assure long lasting performance and low noise generation. djustable eccentric masses allow easy fine tuning of the ax centrifugal force provided by the motor. Several certifications for use in hazardous environments are available in the O range to match the most demanding specification worldwide. Range odel Poles Vibrating orce ,375 Standard ncreased Safety xplosionproof i-stroke illing 2-8 poles V Voltage lass (V) Speed at 50z/ 60z (rpm) 3,000/3, , ,532 Three-phase from 220V to 690V, 50z or 60z. 1,500/1800 1,000/1, , /900 nput Power (kw) icro RO Three-phase from 230V to 460V, 50z or 60z. 3,000/3, Single-phase 115V 60z and 230V 50z. Single-phase V V 60z and 230V 50z. 3,000/3, irect urrent V V and 24V. 3, ,052 3,000/3, ,153 1,500/1, poles V ,009 1,000/1, , /900 Three-phase ,052 from 220V 3,000/3, poles V ,495 to 690V, 50z or 60z. 1,500/1, ,697 1,000/1, , / , / poles V-NG , /720 Jamieson quipmen
9 Range ertifications ategory Type of protection Temperature rating irective Standard Range S T ntertek x 3 lass iv.2 Groups, G N4 nclosure x t 22 Tx P66 icro and up to size 50 = T100 rom size 60 up = T135 onformity with uropean irective ow voltage 2006/95/ 2004/108/ achine irective 2006/42/ TX 94/9/ Standard Range (zone 21) x 2 lass iv.2 Groups, G N4 nclosure x tb 21 Tx b P66 icro and up to size 50 = T100 rom size 60 up = T110 U 1836, U S22,2 NO 25, 100, 145 ncreased Safety x 2G ncreased safety x e T3 x t 21 T150 P66 T3 T150 onformity with uropean irective ow voltage 2006/95/ 2004/108/ achine irective 2006/42/ TX 94/9/ xplosion-proof S T ntertek x 2G lass iv.1 Groups, lass iv.1 Groups,, G P66 lame-proof x d T4 x t 21 P66 T135 x db T4, x tb T135 T4 T135 onformity with uropean irective ow voltage 2006/95/ 2004/108/ achine irective 2006/42/ TX 94/9/ xplosion-proof 5 x 2G lass iv.1 Groups, P66 lame-proof x d T3 P66 x db T3 T3 U 1836, U , U 674 S22,2 NO 25, 100, 145 i-stroke illing x 3 nclosure x t 22 Tx P66 T135 onformity with uropean irective ow voltage 2006/95/ 2004/108/ achine irective 2006/42/ TX 94/9/ Jamieson quipmen
10 hoose rpm and the amplitude e (0 - peak) suitable for your application: ircular vibration inear vibration pplication processes Revolutions Per inute Vibration 50z ircular inear 60z rpm e (mm) in. ax. onveying Separation / Screening / Sizing Positioning / eeding ilter cleaning Silo/hopper emptying luid beds in activators ompacting oncrete consolidation 3, , , , , , , hoose an V from the tables of the following pages and use its Wm into this formula: e = 5 n Wm n mot vm e n Wm mot vm = amplitude of vibration 0-peak (mm) = number of vibrating motors = working moment (kgcm) = motor weight = vibrating machine weight (without material and motors) Jamieson quipmen
11 heck the obtained value e : f it is similar to the required one (step 1) the V model is correct. f it is not similar to the required one (step 1) repeat the process (step 2) with a different V model. or tips on installation see section page 40 VOTG elta / Star requency (z) Standard / / 60 Several voltages are available to match local electric specifications worldwide both at 50z and 60z. ll O motors can be operated with double voltage by simply changing the connections inside the terminal box from Star to elta or vice-versa. Three-phase Vs with double rated voltage: (Star) igh Voltage - actory preset (elta) ow Voltage Vs with (elta) : (elta) ow Voltage - actory preset (Star) igh Voltage 220 (Single-phase) / / 460 * (Single-phase) / 575 * / (elta) / (elta) (elta) * (elta) (elta) * (Three-phase) 50 / (Single-phase) 60 or details about Star and elta connections see page (Single-phase) / / 60 * Voltage Tolerance: % Jamieson quipmen
12 » 3 x t 22 Tx P66» TÜV NOR Statement onformity Number TÜV 05 TX 2768X» quipment and protective system intended for use in potentially explosive atmospheres (Zone 22) - irective 94/9/» ompliance with ssential ealth and Safety Requirements» S T ntertek * NØ * mage referred to size 50 TR SPTONS RTT Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max. (Y) a / n able Gland lass iv z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (400V) 60z (460V) 50z 60z etric Temp. lass Temp. lass 1 1 V 60/3 V 60/ T V 100/3 V 100/ T V 200/3 V 200/ T V 202/3 V 202/ T V 300/3 V 300/ T V 400/3 V 400/ T V 500/3 V 500/ T V 700/3 V 700/ T V 800/3 V 800/ T V 1200/3 V 1200/36 1,005 1, T V 1300/3 V 1300/36 1,355 1, T V 1301/3 V 1301/36 1,355 1, T V 1310/3 V 1310/36 1,123 1, T V 1600/3 V 1600/36 1,601 1, T V 2000/3 V 2000/36 2,027 1, T V 2300/3 V 2300/36 2,302 2, T V 3200/3 V 3200/36 3,252 3, T V 4000/3 V 4000/36 4,033 4, T V 5000/3 V 5000/36 5,009 5, T4 135 max. (Δ) V 6500/3 V 6500/36 6,510 6, T V 9000/3 V 9000/36 9,025 9, T4 135 Jamieson quipmen
13 » eclaration of conformity type according to: 2006/95/ /108/ /42/ - N S T ntertek» lass iv.2 Group, G - T4 - N 4» onform to U 1836, U ert. S 22.2 N. 25, 100, 145» ntertek T - SO ile Number odel rawing Size NSON SPTONS (mm) Ø G oles N 50z 60z 50z 60z 50z 60z N V 60/3 V 60/ ultiple ootprint V 100/3 V 100/ V 200/3 V 200/ V 202/3 V 202/36 G V 300/3 V 300/ ultiple ootprint ultiple ootprint V 400/3 V 400/ V 500/3 V 500/ V 700/3 V 700/ V 800/3 V 800/ V 1200/3 V 1200/ V 1300/3 V 1300/ V 1301/3 V 1301/ V 1310/3 V 1310/ V 1600/3 V 1600/ V 2000/3 V 2000/ V 2300/3 V 2300/ V 3200/3 V 3200/ V 4000/3 V 4000/ V 5000/3 V 5000/ NØ V 6500/3 V 6500/ V 9000/3 V 9000/ NOT: imensions with coarse degree of accuracy related to UN 22768/1 This information is provided without warranty, representation, inducement or licence of any kind. t is accurate to the best O knowledge or is obtained from sources believed to be accurate. O therefore assumes no legal responsibility. Jamieson quipmen
14 » 3 x t 22 Tx P66» TÜV NOR Statement onformity Number TÜV 05 TX 2768X» quipment and protective system intended for use in potentially explosive atmospheres (Zone 22) - irective 94/9/» ompliance with ssential ealth and Safety Requirements» S T ntertek * NØ * mage referred to size 90 TR SPTONS RTT Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max. (Y) a / n able Gland lass iv z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (400V) 60z (460V) 50z 60z etric Temp. lass Temp. lass 2 2 V 40/15 V 40/ T V 90/15 V 90/ T V 200/15 V 200/ T V 400/15 V 400/ T V 500/15 V 500/ T V 300/15 V 300/ T V 700/15 V 700/ T V 1100/15 V 1100/ T V 1400/15 V 1400/ T V 1700/15 V 1700/ T V 2400/15 V 2400/ T V 2500/15 V 2500/ T V 3000/15 V 3000/ T V 3800/15 V 3800/ T V 4300/15 V 4300/ T V 5500/15 V 5500/ T4 135 max. (Δ) V 7200/15 V 7200/ T V 9000/15 V 9000/ T V 10000/15 V 10000/ T V 11500/15 V 11500/ V 14500/15 V 14500/ UP TO SZ 60 (NOT NU) 60z masses = 50z masses adjusted at 70% xcept for model V 1100/ /18 OV SZ 60 (NU) Specific masses for 60z To convert kg into Newton: N = 9.81 kg Jamieson quipmen
15 » eclaration of conformity type according to: 2006/95/ /108/ /42/ - N S T ntertek» lass iv.2 Group, G - T4 - N 4» onform to U 1836, U ert. S 22.2 N. 25, 100, 145» ntertek T - SO ile Number odel rawing 50z 60z 50z 60z 50z 60z N ultiple ootprint V 40/15 V 40/ V 90/15 V 90/ ultiple ootprint V 200/15 V 200/ V 400/15 V 400/ V 500/15 V 500/ V 300/15 V 300/ V 700/15 V 700/ V 1100/15 V 1100/ V 1400/15 V 1400/ V 1700/15 V 1700/ V 2400/15 V 2400/ V 2500/15 V 2500/ V 3000/15 V 3000/ V 3800/15 V 3800/ V 4300/15 V 4300/ V 5500/15 V 5500/ NSON SPTONS (mm) Ø G oles N Size V 7200/15 V 7200/ V 9000/15 V 9000/ V 10000/15 V 10000/ V 11500/15 V 11500/ V 14500/15 V 14500/ NOT: imensions with coarse degree of accuracy related to UN 22768/1 This information is provided without warranty, representation, inducement or licence of any kind. t is accurate to the best O knowledge or is obtained from sources believed to be accurate. O therefore assumes no legal responsibility. Jamieson quipmen
16 » 3 x t 22 Tx P66» TÜV NOR Statement onformity Number TÜV 05 TX 2768X» quipment and protective system intended for use in potentially explosive atmospheres (Zone 22) - irective 94/9/» ompliance with ssential ealth and Safety Requirements» S T ntertek * 1 * 2 * 1 mage referred to size 105 * 2 mage referred to size 30 TR SPTONS RTT Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max. (Y) a / n able Gland lass iv z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (400V) 60z (460V) 50z 60z etric Temp. lass Temp. lass 9 7 V 50/1 V 50/ T V 100/1 V 100/ T V 200/1 V 200/ T V 300/1 V 300/ T V 500/1 V 500/ T V 510/1 V 510/ T V 800/1 V 800/ T V 1100/1 V 1100/12 1,048 1, T V 1500/1 V 1500/12 1,590 1, T V 1600/1 V 1600/12 1,673 1, T V 2100/1 V 2100/12 2,083 2, T V 2600/1 V 2600/12 2,610 2, T V 3000/1 V 3000/12 3,017 3, T V 5210/1 V 5210/12 5,237 5, T V 3800/1 V 3800/12 3,799 3, T V 4700/1 V 4700/12 4,681 4, T V 5200/1 V 5200/12 5,192 5, T V 6500/1 V 6500/12 6,506 6, T4 135 max. (Δ) 1, V 8000/1 V 8000/12 8,018 7, T ,165 V 9000/1 V 9000/12 8,936 9, T ,788 1,240 V 10000/1 V 10000/12 9,986 9, T ,330 1,647 V 13000/1 V 13000/12 13,009 13, T ,253 1,550 V 12000/1 V 12000/12 12,580 12, ,634 1,856 V 15000/1 V 15000/12 14,706 14, ,220 2,147 V 17500/1 V 17500/12 17,980 17, ,632 2,525 V 19500/1 V 19500/12 20,285 20, ,067 2,622 V 22000/1 V 22000/12 22,711 21, ,572 3,163 V 25000/1 V 25000/12 25,532 25, UP TO SZ 60 (NOT NU) 60z masses = 50z masses adjusted at 70% OV SZ 60 (NU) Specific masses for 60z To convert kg into Newton: N = 9.81 kg Jamieson quipmen
17 » eclaration of conformity type according to: 2006/95/ /108/ /42/ - N S T ntertek» lass iv.2 Group, G - T4 - N 4» onform to U 1836, U ert. S 22.2 N. 25, 100, 145» ntertek T - SO ile Number odel rawing NSON SPTONS (mm) Ø G oles N Size 50z 60z 50z 60z 50z 60z N ultiple ootprint V 50/1 V 50/ V 100/1 V 100/ V 200/1 V 200/ V 300/1 V 300/ V 500/1 V 500/ V 510/1 V 510/ V 800/1 V 800/ V 1100/1 V 1100/ V 1500/1 V 1500/ V 1600/1 V 1600/ V 2100/1 V 2100/ V 2600/1 V 2600/ V 3000/1 V 3000/ V 5210/1 V 5210/ V 3800/1 V 3800/ V 4700/1 V 4700/ V 5200/1 V 5200/ V 6500/1 V 6500/ V 8000/1 V 8000/ V 9000/1 V 9000/ V 10000/1 V 10000/ V 13000/1 V 13000/ V 12000/1 V 12000/ , V 15000/1 V 15000/ V 17500/1 V 17500/ , V 19500/1 V 19500/ , V 22000/1 V 22000/ , V 25000/1 V 25000/ , Jamieson quipmen
18 » 3 x t 22 Tx P66» TÜV NOR Statement onformity Number TÜV 05 TX 2768X» quipment and protective system intended for use in potentially explosive atmospheres (Zone 22) - irective 94/9/» ompliance with ssential ealth and Safety Requirements» S T ntertek * 1 * 2 * 1 mage referred to size 110 * 2 mage referred to size 40 TR SPTONS RTT Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max. (Y) a / n able Gland lass iv z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (400V) 60z (460V) 50z 60z etric 33 V 150/075 V 150/ T V 250/075 V 250/ T V 400/075 V 400/ T V 650/075 V 650/ T V 900/075 V 900/ T V 1300/075 V 1300/ , T V 2100/075 V 2100/090 1,468 2, T V 3100/075 V 3100/090 2,137 3, T V 3800/075 V 3800/090 2,633 3, T V 4200/075 V 4200/090 2,920 4, T ,165 V 5300/075 V 5300/090 3,660 5, T ,436 V 6500/075 V 6500/090 4,510 6, T4 135 max. (Δ) 2,200 V 10000/075 V 10000/090 6,911 9, T ,835 2,553 V 12000/075 V 12000/090 8,904 11, ,713 3,220 V 14000/075 V 14000/090 11,661 14, ,401 3,920 V 17000/075 V 17000/090 13,822 17, ,857 4,999 V 22000/075 V 22000/090 18,395 22, ,857 N V 26000/090-26, Temp. lass Temp. lass UP TO SZ (NU) (NOT NU) 60z masses = 50z masses adjusted at 100% 70% OV SZ (NOT (NU) NU) Specific masses for 60z To convert kg into Newton: N = 9.81 kg Jamieson quipmen
19 » eclaration of conformity type according to: 2006/95/ /108/ /42/ - N S T ntertek» lass iv.2 Group, G - T4 - N 4» onform to U 1836, U ert. S 22.2 N. 25, 100, 145» ntertek T - SO ile Number odel rawing NSON SPTONS (mm) Ø G oles N Size 50z 60z 50z 60z 50z 60z N V 150/075 V 150/ V 250/075 V 250/ V 400/075 V 400/ V 650/075 V 650/ V 900/075 V 900/ V 1300/075 V 1300/ V 2100/075 V 2100/ V 3100/075 V 3100/ V 3800/075 V 3800/ V 4200/075 V 4200/ V 5300/075 V 5300/ V 6500/075 V 6500/ V 10000/075 V 10000/ V 12000/075 V 12000/ , V 14000/075 V 14000/ , V 17000/075 V 17000/ , V 22000/075 V 22000/ , N V 26000/ , NOT: imensions with coarse degree of accuracy related to UN 22768/1 This information is provided without warranty, representation, inducement or licence of any kind. t is accurate to the best O knowledge or is obtained from sources believed to be accurate. O therefore assumes no legal responsibility. Jamieson quipmen
20 » 3 x t 22 Tx P66» TÜV NOR Statement onformity Number TÜV 05 TX 2768X» quipment and protective system intended for use in potentially explosive atmospheres (Zone 22) - irective 94/9/» ompliance with ssential ealth and Safety Requirements» S T ntertek * 1 * 1 mage referred to size 20 TR SPTONS RTT Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max a / n able Gland apacitor * lass iv z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (230V ) 60z (115V) 50z 60z etric 50z (230V) 60z (115V) Temp. lass Temp. lass 1 1 V 60/ μ 6,3 μ T V 100/ μ 8 μ T V 200/ μ 16 μ T V 202/ μ 16 μ T V 300/ ,5 μ 25 μ T4 100 * NOT: apacitor not supplied with vibrator (to be ordered separately) Jamieson quipmen
21 » eclaration of conformity type according to: 2006/95/ /108/ /42/ - N S T ntertek» lass iv.2 Group, G - T4 - N 4» onform to U 1836, U ert. S 22.2 N. 25, 100, 145» ntertek T - SO ile Number NØ odel rawing Size NSON SPTONS (mm) Ø G oles N 50z 60z 50z 60z 50z 60z N V 60/ ultiple ootprint V 100/ V 200/ V 202/3 G V 300/ ultiple ootprint ultiple ootprint NØ NOT: imensions with coarse degree of accuracy related to UN 22768/1 This information is provided without warranty, representation, inducement or licence of any kind. t is accurate to the best O knowledge or is obtained from sources believed to be accurate. O therefore assumes no legal responsibility. Jamieson quipmen
22 » 3 x t 22 Tx P66» TÜV NOR Statement onformity Number TÜV 05 TX 2768X» quipment and protective system intended for use in potentially explosive atmospheres (Zone 22) - irective 94/9/» ompliance with ssential ealth and Safety Requirements» S T ntertek TR SPTONS RTT Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max able Gland or 60z lass iv.2 or 50z 3 50z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (230V) 50z (400V) 60z (460V) etric Temp. lass Temp. lass RO T RO T4 100 TR SPTONS RTT Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max able Gland * or 60z lass iv.2 or 50z 3 50z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (230V) 60z (115V) etric Temp. lass Temp. lass RO T RO T RO T RO T4 100 NOT: apacitor integrated in the cable Jamieson quipmen
23 » eclaration of conformity type according to: 2006/95/ /108/ /42/ - N S T ntertek» lass iv.2 Group, G - T4 - N 4» onform to U 1836, U ert. S 22.2 N. 25, 100, 145» ntertek T - SO ile Number odel rawing NSON SPTONS (mm) Ø G oles N 50z 60z 50z 50z N ultiple ootprint RO 21/ ultiple ootprint RO 41/ NSON SPTONS (mm) otor Name rawing Ø G oles N 50z 60z 50z 50z N ultiple ootprint RO 3/ RO 6/ RO 21/ RO 41/ ultiple ootprint ultiple ootprint ultiple ootprint NOT: imensions with coarse degree of accuracy related to UN 22768/1 This information is provided without warranty, representation, inducement or licence of any kind. t is accurate to the best O knowledge or is obtained from sources believed to be accurate. O therefore assumes no legal responsibility. Jamieson quipmen
24 » 3 x t 22 Tx P66» TÜV NOR Statement onformity Number TÜV 05 TX 2768X» quipment and protective system intended for use in potentially explosive atmospheres (Zone 22) - irective 94/9/» ompliance with ssential ealth and Safety Requirements» S T ntertek * * mage referred to size 23 TR SPTONS RTT Wm (kgcm) odel rpm entrifugal orce Weight nput Power (kw) Nominal urrent max able Gland 3 1 V V V V V V V V Jamieson quipmen
25 » eclaration of conformity type according to: 2006/95/ /108/ /42/ - N S T ntertek» lass iv.2 Group, G - T4 - N 4» onform to U 1836, U ert. S 22.2 N. 25, 100, 145» ntertek T - SO ile Number NØ NØ odel rawing Size Ø G V ultiple ootprint NSON SPTONS (mm) oles N N V V G ultiple ootprint V G V G V G V V NOT: imensions with coarse degree of accuracy related to UN 22768/1 This information is provided without warranty, representation, inducement or licence of any kind. t is accurate to the best O knowledge or is obtained from sources believed to be accurate. O therefore assumes no legal responsibility. Jamieson quipmen
26 » 2G x e T3 x t 21 T150 P66» quipment and protective system intended for use in potentially explosive atmospheres (Zone 21 - Zone 1) - irective 94/9/» ompliance with ssential ealth and Safety Requirements» * NØ * mage referred to size 60 TR SPTONS RTT Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max. (Y) a / n able Gland Temp. lass 50z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (400V) 60z (460V) 50z 60z etric GS T 4 3 V 200/3 V 200/ T V 202/3 V 202/ T V 300/3 V 300/ T V 400/3 V 400/ T V 500/3 V 500/ T V 700/3 V 700/ T V 800/3 V 800/ T V 1200/3 V 1200/36 1,005 1, T V 1300/3 V 1300/36 1,355 1, T V 1301/3 V 1301/36 1,355 1, T V 1310/3 V 1310/36 1,123 1, T V 1600/3 V 1600/36 1,601 1, T V 2000/3 V 2000/36 2,027 1, T V 2300/3 V 2300/36 2,302 2, T V 3200/3 V 3200/36 3,252 3, T V 4000/3 V 4000/36 4,033 4, T3 150 Jamieson quipmen
27 » eclaration of conformity type according to: 2006/95/ /108/ /42/ - N » x S X/2» ert. n. aseefa 06TX0281X/2 odel rawing Size NSON SPTONS (mm) Ø G oles N 50z 60z 50z 60z 50z 60z N V 200/3 V 200/ V 202/3 V 202/36 G V 300/3 V 300/ ultiple ootprint ultiple ootprint V 400/3 V 400/ V 500/3 V 500/ V 700/3 V 700/ V 800/3 V 800/ V 1200/3 V 1200/ V 1300/3 V 1300/ V 1301/3 V 1301/ V 1310/3 V 1310/ V 1600/3 V 1600/ V 2000/3 V 2000/ V 2300/3 V 2300/ V 3200/3 V 3200/ V 4000/3 V 4000/ NØ Jamieson quipmen
28 » 2G x e T3 x t 21 T150 P66» quipment and protective system intended for use in potentially explosive atmospheres (Zone 21 - Zone 1) - irective 94/9/» ompliance with ssential ealth and Safety Requirements» * NØ * mage referred to size 78 TR SPTONS RTT Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max. (Y) a / n able Gland Temp. lass 50z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (400V) 60z (460V) 50z 60z etric GS T V 200/15 V 200/ T V 400/15 V 400/ T V 500/15 V 500/ T V 300/15 V 300/ T V 700/15 V 700/ T V 1100/15 V 1100/18 1,114 1, T V 1400/15 V 1400/18 1,364 1, T V 1700/15 V 1700/18 1,725 1, T V 2400/15 V 2400/18 2,358 2, T V 2500/15 V 2500/18 2,557 2, T V 3000/15 V 3000/18 3,124 3, T V 3800/15 V 3800/18 3,853 3, T V 4300/15 V 4300/18 4,312 4, T V 5500/15 V 5500/18 5,495 5, T3 150 max. (Δ) V 7200/15 V 7200/18 7,246 7, T V 9000/15 V 9000/18 9,020 9, T V 10000/15 V 10000/18 10,052 10, T V 11500/15 V 11500/18 11,779 11, , V 14500/15 V 14500/18 14,352 15, Jamieson quipmen
29 » eclaration of conformity type according to: 2006/95/ /108/ /42/ - N » x S X/2» ert. n. aseefa 06TX0281X/2 odel rawing 50z 60z 50z 60z 50z 60z N ultiple ootprint V 200/15 V 200/ V 400/15 V 400/ V 500/15 V 500/ V 300/15 V 300/ V 700/15 V 700/ V 1100/15 V 1100/ V 1400/15 V 1400/ V 1700/15 V 1700/ V 2400/15 V 2400/ V 2500/15 V 2500/ V 3000/15 V 3000/ V 3800/15 V 3800/ V 4300/15 V 4300/ V 5500/15 V 5500/ NSON SPTONS (mm) Ø G oles N Size V 7200/15 V 7200/ V 9000/15 V 9000/ V 10000/15 V 10000/ V 11500/15 V 11500/ V 14500/15 V 14500/ Jamieson quipmen
30 » 2G x e T3 x t 21 T150 P66» quipment and protective system intended for use in potentially explosive atmospheres (Zone 21 - Zone 1) - irective 94/9/» ompliance with ssential ealth and Safety Requirements» * 1 *2 * 1 mage referred to size 75 * 2 mage referred to size 85 TR SPTONS RTT Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max. (Y) a / n able Gland Temp. lass 50z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (400V) 60z (460V) 50z 60z etric GS T 9 7 V 50/1 V 50/ T V 100/1 V 100/ T V 200/1 V 200/ T V 300/1 V 300/ T V 500/1 V 500/ T V 510/1 V 510/ T V 800/1 V 800/ T V 1100/1 V 1100/12 1,048 1, T V 1500/1 V 1500/12 1,590 1, T V 1600/1 V 1600/12 1,673 1, T V 2100/1 V 2100/12 2,083 2, T V 2600/1 V 2600/12 2,610 2, T V 3000/1 V 3000/12 3,017 3, T V 5210/1 V 5210/12 5,237 5, T V 3800/1 V 3800/12 3,799 3, T V 4700/1 V 4700/ , T V 5200/1 V 5200/12 5,192 5, T , V 6500/1 V 6500/12 6,506 6, T3 150 max. (Δ) 1, V 8000/1 V 8000/12 8,018 7, T ,600 1,165 V 9000/1 V 9000/12 8,936 9, T ,788 1,240 V 10000/1 V 10000/12 9,986 9, T ,330 - V 13000/1 N 13, T3 150 Jamieson quipmen
31 » eclaration of conformity type according to: 2006/95/ /108/ /42/ - N » x S X/2» ert. n. aseefa 06TX0281X/2 odel rawing NSON SPTONS (mm) Ø G oles N Size 50z 60z 50z 60z 50z 60z N ultiple ootprint V 50/1 V 50/ V 100/1 V 100/ V 200/1 V 200/ V 300/1 V 300/ V 500/1 V 500/ V 510/1 V 510/ V 800/1 V 800/ V 1100/1 V 1100/ V 1500/1 V 1500/ V 1600/1 V 1600/ V 2100/1 V 2100/ V 2600/1 V 2600/ V 3000/1 V 3000/ V 5210/1 V 5210/ V 3800/1 V 3800/ V 4700/1 V 4700/ V 5200/1 V 5200/ V 6500/1 V 6500/ V 8000/1 V 8000/ V 9000/1 V 9000/ V 10000/1 V 10000/ V 13000/1 N Jamieson quipmen
32 » 2G x e T3 x t 21 T150 P66» quipment and protective system intended for use in potentially explosive atmospheres (Zone 21 - Zone 1) - irective 94/9/» ompliance with ssential ealth and Safety Requirements» * * mage referred to size 90 TR SPTONS RTT Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max. (Y) a / n able Gland Temp. lass 50z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (400V) 60z (460V) 50z 60z etric GS T 33 V 150/075 V 150/ T V 250/075 V 250/ T V 400/075 V 400/ T V 650/075 V 650/ T V 900/075 V 900/ T V 1300/075 V 1300/ , T V 2100/075 V 2100/090 1,468 2, T V 3100/075 V 3100/090 2,137 3, T V 3800/075 V 3800/090 2,633 3, T V 4200/075 V 4200/090 2,920 4, T ,165 V 5300/075 V 5300/090 3,660 5, T ,436 V 6500/075 V 6500/090 4,510 6, T ,200 V 10000/075 V 10000/090 max. (Δ) 6,911 9, T3 150 Jamieson quipmen
33 » eclaration of conformity type according to: 2006/95/ /108/ /42/ - N » x S X/2» ert. n. aseefa 06TX0281X/2 odel rawing NSON SPTONS (mm) Ø G oles N Size 50z 60z 50z 60z 50z 60z N V 150/075 V 150/ V 250/075 V 250/ V 400/075 V 400/ V 650/075 V 650/ V 900/075 V 900/ V 1300/075 V 1300/ V 2100/075 V 2100/ V 3100/075 V 3100/ V 3800/075 V 3800/ V 4200/075 V 4200/ V 5300/075 V 5300/ V 6500/075 V 6500/ V 10000/075 V 10000/ Jamieson quipmen
34 S T S T ntertek» 2G x d T4 x t 21 P66 T135» x d T4 Gb» x t 21 T135 b P66» lass iv.1 groups, lass iv.1 groups,, G T4 P66 ntertek» 2G x d T3» x d T3 Gb» lass iv.1 groups, T3 S T ntertek * * mage referred to size 78 TR SPTONS Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max. (Y) a / n able Gland 50z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (400V) 60z (460V) 50z 60z etric V 800/3 V 800/ V 1300/3 V 1300/36 1,355 1, V 1600/3 V 1600/36 1,601 1, V 2000/3 V 2000/36 2,027 1, V 2300/3 V 2300/36 2,302 2, V 3200/3 V 3200/36 3,252 3, V 4000/3 V 4000/36 4,033 4, TR SPTONS Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max. (Y) a / n able Gland 50z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (400V) 60z (460V) 50z 60z etric V 700/15 V 700/ V 1100/15 V 1100/18 1,114 1, V 1400/15 V 1400/18 1,364 1, V 1700/15 V 1700/18 1,725 1, V 2400/15 V 2400/18 2,358 2, V 2500/15 V 2500/18 2,557 2, V 3000/15 V 3000/18 3,124 3, V 3800/15 V 3800/18 3,853 3, V 3810/15 V 3810/18 3,853 3, V 3811/15 V 3811/18 2,425 3, V 4300/15 V 4300/18 4,312 4, V 5500/15 V 5500/18 5,495 5, /4 NPT Jamieson quipmen
35 » eclaration of conformity type according to: 2006/95/ /108/ /42/ - N » ; ; » x TUN X S T ntertek» onform to U 1836, U1004-1, U674» ert. S 22.2 N. 25, 100, 145 odel rawing Size NSON SPTONS (mm) Ø G oles N 50z 60z 50z 60z 50z 60z N V 800/3 V 800/ V 1300/3 V 1300/ V 1600/3 V 1600/ V 2000/3 V 2000/ V 2300/3 V 2300/ V 3200/3 V 3200/ V 4000/3 V 4000/ odel rawing Size NSON SPTONS (mm) Ø G oles N 50z 60z 50z 60z 50z 60z N V 700/15 V 700/ V 1100/15 V 1100/ V 1400/15 V 1400/ V 1700/15 V 1700/ V 2400/15 V 2400/ V 2500/15 V 2500/ V 3000/15 V 3000/ V 3800/15 V 3800/ V 3810/15 V 3810/ V 3811/15 V 3811/ V 4300/15 V 4300/ V 5500/15 V 5500/ Jamieson quipmen
36 S T S T ntertek» 2G x d T4 x t 21 P66 T135» x d T4 Gb» x t 21 T135 b P66» lass iv.1 groups, lass iv.1 groups,, G T4 P66 ntertek» 2G x d T3» x d T3 Gb» lass iv.1 groups, T3 S T ntertek * * mage referred to size 60 TR SPTONS Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max. (Y) a / n able Gland 50z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (400V) 60z (460V) 50z 60z etric 92 V 500/1 V 500/ V 800/1 V 800/ V 1100/1 V 1100/12 1,048 1, V 1500/1 V 1500/12 1,590 1, V 1600/1 V 1600/12 1,673 1, V 2100/1 V 2100/12 2,083 2, V 2600/1 V 2600/12 2,610 2, V 3000/1 V 3000/12 3,017 3, V 3800/1 V 3800/12 3,799 3, V 4700/1 V 4700/12 4,681 4, /4 NPT UP TO SZ 60 (NU) 60z masses = 50z masses adjusted at 70% OV SZ 60 (NOT NU) Specific masses for 60z xcept for model V 1500/1-1500/12 TR SPTONS Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max. (Y) a / n able Gland 50z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (400V) 60z (460V) 50z 60z etric 57 V 250/075 V 250/ V 400/075 V 400/ V 650/075 V 650/ V 900/075 V 900/ V 1300/075 V 1300/ , V 2100/075 V 2100/090 1,468 2, V 3100/075 V 3100/090 2,137 3, V 3800/075 V 3800/090 2,633 3, /4 NPT Jamieson quipmen
37 » eclaration of conformity type according to: 2006/95/ /108/ /42/ - N » ; ; » x TUN X S T ntertek» onform to U 1836, U1004-1, U674» ert. S 22.2 N. 25, 100, 145 odel rawing NSON SPTONS (mm) Ø G oles N Size 50z 60z 50z 60z 50z 60z N V 500/1 V 500/ V 800/1 V 800/ V 1100/1 V 1100/ V 1500/1 V 1500/ V 1600/1 V 1600/ V 2100/1 V 2100/ V 2600/1 V 2600/ V 3000/1 V 3000/ V 3800/1 V 3800/ V 4700/1 V 4700/ NSON SPTONS (mm) odel rawing Ø G oles N Size 50z 60z 50z 60z 50z 60z N V 250/075 V 250/ V 400/075 V 400/ V 650/075 V 650/ V 900/075 V 900/ V 1300/075 V 1300/ V 2100/075 V 2100/ V 3100/075 V 3100/ V 3800/075 V 3800/ Jamieson quipmen
38 » 3 x t 22 Tx P66» TÜV NOR Statement onformity Number TÜV 05 TX 2768X» quipment and protective system intended for use in potentially explosive atmospheres (Zone 22) - irective 94/9/» ompliance with ssential ealth and Safety Requirements» TR SPTONS RTT Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max. (Y) a / n able Gland 3 50z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (400V) 60z (460V) 50z 60z etric Temp. lass V 1200/075 N 1, V 1400/075 N 1, TR SPTONS RTT Wm (kgcm) odel entrifugal orce Weight nput Power (kw) Nominal urrent max. (Δ) a / n able Gland 3 50z 60z 50z 60z 50z 60z 50z 60z 50z 60z 50z (400V) 60z (460V) 50z 60z etric Temp. lass 383 V 1200/060 V 1200/ , V 1400/060 V 1400/ , Jamieson quipmen
39 » eclaration of conformity type according to: 2006/95/ /108/ /42/ - N odel rawing NSON SPTONS (mm) Ø G oles 1 1 N Size 50z 60z 50z 60z 50z 60z N V 1200/075 N V 1400/075 N NSON SPTONS (mm) odel rawing Ø G oles 1 1 N Size 50z 60z 50z 60z 50z 60z N V 1200/060 V 1200/ V 1400/060 V 1400/ Jamieson quipmen
40 The base plate surface where the vibrator motor is mounted has an allowable tolerance of 0.25mm (0.01in), so that the surfaces rest uniformly against each other to avoid internal tension that may cause breakage of the foot of the vibrator motor. Use 8.8 type bolts, 8.0 type nuts and flat washers belonging to category N SO 7089 / The graph below show the correct torque settings for the different bolt sizes used on the motor vibrators. Screw Washer lamping torque etric mperial etric mperial UN 6592 lat washer (Nm) (ftlb) 6 1/4" 6.4 x 12 1/4" /16" 8.4 x 16 5/16" /8" 10.5 x 20 3/8" /2" 13 x 24 1/2" /8" 17 x 30 5/8" /16" 21 x 37 13/16" /8" 23 x 39 7/8" /16" 25 x 44 15/16" " 28 x 50 1" /8" 37 x /8" 1,864 1, /8 37 x /8 2,850 2,102 XNG Smooth through borehole + screw + flat washer + nut and counternut SUR TNSS TORN Plate thickness recommended: ØS ØS Tapped threaded borehole + screw + flat washer ax 0.25mm (0.01in) N & NOT PNT SUPPORT PT Jamieson quipmen
41 ake sure the voltage and frequency supply match the ones indicated on the rating plate of the electric vibrator. f the motor is operated via a variable frequency drive do not run it under 20 z and not over the rated frequency. nsert the power cable through the cable gland. The lead-in wires have to be of the eyelet-type, pre-insulated, with a bore that suits the terminals of the junction box in order to prevent overheating of the wire. Use only conductors that have a suitable cross-section. onnect the lead wires to the pins (as shown in the diagram below) and tighten them with the specified torque: o not forget to fix the earthing cable to the provided studs ompulsory connection! efore closing the junction box make sure the cover gasket is properly fitted in order to keep the specified P protection. or more details on motor installation refer to product manuals. Junction box nuts tightening torque Screw Nm ftlb Y TRN ONNTONS G VOTG ptc P2 P1 OW VOTG W2 U2 V2 W2 U2 V2 ptc P2 P U1 V1 W1 U1 V1 W heck Nominal urrent column label to know the factory preset connection of each motor. ll electric vibrators T be connected to a suitable external overload protection. When using two electric vibrators in sync, each of them has to be connected to an external overload protection that must be interlocked to make sure both motors are stopped if one fails. lways use a thermal-magnetic type motor protection, with delayed cut-off, to avoid stopping the motor during start-up when the current draw is higher than the rated running current for a few seconds. ut-off of the overload protection should be set at a maximum of +10% of the rated current. Jamieson quipmen
42 SSS T 100% JT SSS NORRTY JT SSS 2 TPS TO ORRTY JT SSS: Rotate the mass following the design on the plate: from the thicker tip towards the thin tip S z 50z Rotate the masses in the opposite direction to the cable gland. left side of the motor, for sizes up to 60 left side right side The fissure in the mass indicates the degree of adjustment. Rotate the mass following the design on the plate: from the thicker tip towards the thin tip. 0% S z 50z 100% SSS T 100% JT SSS Jamieson quipmen
43 SSS T 100% JT SSS or technical information on the regulation of blade masses refer to the Use and aintenance anual. Warning: O NOT grease new motors before installation. O motors with roller bearings leave the factory filled with the right quantity of grease while those with ball bearing do not need any lubrication. Jamieson quipmen
INDUSTRIAL VIBRATORS
NTR VRTORS T WORW R N VRTON TNOOGY 2 ntro ompany profile 4 Technical features 6 Standard specifications 7 The O vibrator range 8 ertifications 9 ow to choose a motovibrator 10 V standard range 2 poles
More informationINDUSTRIAL VIBRATORS
NTR VRTORS T WORW R N VRTON TNOOGY 2 ntro ompany profile 4 Technical features 6 Standard specifications 7 The O vibrator range 8 ertifications 9 ow to choose a motovibrator 10 V standard range 2 poles
More informationINDUSTRIAL VIBRATORS THE WORLDWIDE LEADER IN VIBRATION TECHNOLOGY
NTR VRTORS T WORW R N VRTON TNOOGY 2 ntro ompany profile 4 Technical features 6 Standard specifications 7 The O vibrator range 8 ertifications 9 ow to choose a motovibrator 10 V standard range 2 poles
More informationINDUSTRIAL VIBRATORS
INDTRIA VIBRATORS TH WORDWID ADR IN VIBRATION THNOOGY Intro ompany profile 4 Technical features 6 Standard specifications 7 The OI vibrator range 8 ertifications 9 How to choose a motovibrator 10 V standard
More informationVISAM MOTOVIBRATORS DESIGNED TO MEET YOUR NEEDS
VISAM MOTOVIBRATORS DESIGNED TO MEET YOUR NEEDS 2 Intro Company profile 4 Technical features 6 Standard specifications 7 The VISAM vibrator range 8 Certifications 9 How to choose a motovibrator 10 SP range
More informationCONCRETE CONSOLIDATION
Distributor for CONCRETE CONSOLIDATION THE WORLDWIDE LEADER IN VIBRATION TECHNOLOGY 2 Intro Company profile 4 Vibration of concrete 5 In situ concrete consolidation High frequency internal vibrators 6
More informationCKMS Low Voltage Three-Phase Squirrel-cage Induction Motor TOSHIBA Top Runner Motor. Premium Gold Motor
S-1001 ow Three-Phase Squirrel-cage Induction otor TOSI Top unner otor Premium old otor Premium fficiency for the reen arth igh efficiency technology of TOSI otor for over 120-year-old brings more value
More informationAC Single & Three-Phase Direct Drive Fans
Single & Three-Phase irect rive ans 96 899 99s or over a century... istory Originally formed over years ago as part of the US based Torin orporation, and then established as a U subsidiary in 96; Torin-Sifan
More informationProtection against mechanical impacts IK 08 according to IEC 68, EN Insulation class Class F (155 C), class H (180 C) on request.
MVSI The MVSI series represents the line of reference products for manufacturer s of vibrating machines and plants operating in many industrial sectors and is made up of the largest range on the market,
More informationTechnical features Certifications
The MVSI series represents the line of reference products for manufacturer s of vibrating machines and plants operating in many industrial sectors and is made up of the largest range on the market, with
More informationINDEX MVSI MVSI-TS MVSI-ACC MVSI-E MVSS CDX MVTX MICRO M3 MVCC MTF MTF-E MVB MVB-E-FLC VB-E ITV-VR ITVAF VIBRAVAR CFV MULTIVAR
IDEX Certifications page 3 Foot mounted electric vibrators MVSI MVSI-TS MVSI-CC MVSI-E MVSS CDX MVTX MICRO M3 M3-E MVCC Electric vibrators page 6 Electric vibrators with split covers page 16 xial coupling
More informationAESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY
AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY AESV2S / AESU2S / AESV2S-LA (IE2) HIGH EFFICIENCY AESV3S / AESU3S / AESV3S-LA (IE3) PREMIUM
More informationVDS Series Small Variable Volume Vane Pump
VS SRS SA VARA VU VA PUP VS Series Small Variable Volume Vane Pump eatures q igh efficiency operation with minimal power loss All the performance of the original new VR series mechanisms combines with
More informationPetroleum Hose Reels
Petroleum ose Reels ome uel elivery In-plant Refueling Marine Refueling Off-road Vehicle/quipment Refueling ou an t uy etter Reel. amily owned and operated since 1933 MNUL OR POWR RWIN RLS Series 6000
More informationMOTORING THE WHEELS OF SUCCESS
VIBRATING MOTOR High Efficiency Vibrating Motor MOTORING THE WHEELS OF SUCCESS nqa T E S T E D ISO 9001-2000 CO 1. Foot Base Mounted Motor: Sonal has a wide range of FOOT BASE VIBRATORS MOTORS to meet
More informationExplosion protection. Guaranteed long lifetime
xplosion protection Using the correct and suitable equipment in a hazardous environments is very important. We have the knowledge in advising you the conversions from standard manual hoisting equipment
More information^ % 3/2 5/2 SERIES 362/562. Features. Construction. Nominal Ambient Temp. Ranges. Electrical
Pilot Operated Stainless Steel Spool Valves xplosionproof Solenoid Valves 6 Stainless Steel odies /4" NPT / / SRIS 6/6 eatures Ideal for valve automation for the oil and gas market Reliable, robust design
More informationCustomised drive solutions
Customised drive solutions Electric motors & systems Drive components Services Introduction 03 Halm quality drive technology Over 50 years of experience in developing electric motors with asynchronous
More informationMTF-E. Technical features
Technical features Power supply Threephase voltage from 220V to 690V, 50Hz or 60Hz; suitable for use with a PM inverter from 20Hz to the base frequency with constant torque load profile. Polarity 2 and
More informationVDR13 Design Series Variable Volume Vane Pump
VR SRS VARA VU VA PUP VR13 esign Series Variable Volume Vane Pump to 4l/min 6Pa The new design number 13 was created by modifying some of the components of old design numbers 11 and 1, and the new design
More informationMVSI-TS. Split covers. Technical features
MVSI-TS Split covers The MVSI-TS series, obtained directly from the MVSI series, is characterized by the split weight covers. The weight cover is divided into two halves that can be removed in a radial
More informationLevel Measurement Point level measurement - Vibrating switches
Siemens G 2018 SITRNS LVS200 Overview SITRNS LVS200 is a vibrating point level switch for high, low, or demand level detection of bulk solids. enefits High resistance to mechanical forces Strong vibration
More informationMVSI. Technical features
MVSI The MVSI series represents the line of reference products for manufacturer s of vibrating machines and plants operating in many industrial sectors and is made up of the largest range on the market,
More informationExpand your business with new EXPLOSION PROOF WORK LIGHTS
Expand your business with new EXPLOSION PROOF WORK LIGHTS EXPAND YOUR BUSINESS POTENTIAL SCANGRIP is first-mover when it comes to development of new and innovative LED work lights. Now, we are proud to
More informationHigh Efficiency Centrifugal Motorised Impellers and Fans
igh fficiency entrifugal Motorised mpellers and ans 96 899 99s or over a century... istory Originally formed over years ago within the US based Torin orporation, and established as its subsidiary in 96.
More informationCHMT Series, F Rated Fans
CNTRIFUGAL SINGL INLT FANS CT Series, F400 120 Rated Fans Officially approved to N12101-3 standard (certificate number 0370-CPD-0348) Range of single inlet direct drive centrifugal fans designed for smoke
More informationLinear luminaire with LED Series EXLUX 6002
> latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationMVSS. Technical features
Technical features Power supply Three-phase voltage from 24V to 690V, 50Hz or 60Hz or 100-130V 60Hz and 200-240V, 50Hz; suitable for use with an inverter from 20Hz to the base frequency with constant torque
More informationELECTRIC VIBRATORS SPV & SPC
ELECTRIC VIBRATORS FOR INDUSTRY SPV & SPC SERIES 1 THE PRODUCT The Newest Design in the World: a range of Electric Vibrator Motors designed and built by vibration engineers and specialists, incorporating
More informationFilled System Thermometers
illed System Thermometers Model N & NR Mechanical Thermometers ata sheet : ST/2012 The Rototherm range of filled system thermometers offer tough yet accurate instruments with rigid stems for direct mounting
More informationKeeping Industry Turning
Keeping Industry Turning W high voltage, high output 0154E issue Specification, standards & introduction Specification W high voltage, high output Standards Specification The W high voltage,high output
More informationSYSTEM COMPONENTS ELECTRIC MOTORS
SYSTM COMPONNTS LCTRIC MOTORS 2 lectric Motors POWR JACKS CAN SUPPLY LCTRIC MOTORS OR ALL APPLICATIONS WHTHR AC OR C MOTORS AR RQUIR. C & -Series Screw Jacks Company Overview Capability 1 3 OUR XPRTIS
More informationQuality in vibrators. Pneumatic vibrators for industries. Conveying Filling Compacting Separating. Detailed technical data:
Quality in vibrators Pneumatic vibrators for industries Detailed technical data: www.findeva.com Conveying Filling Compacting Separating Findeva AG Loostrasse 2 CH-8461 Oerlingen Switzerland www.findeva.com
More informationLinear Luminaire with LED Series EXLUX 6002
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationKeeping Industry Turning
Keeping Industry Turning W low voltage, high output 0153E issue 3 Specification, standards & introduction Specification W low voltage, high output Standards Specification The W low voltage,high output
More informationNM, NMS 60 Hz NM, NMS. Close Coupled Centrifugal Pumps with flanged connections. Construction. Applications. Operating conditions.
, S z lose oupled entrifugal ups Materials oponents, S, S up casing ast iron ronze Lantern bracket asing cover for S GJL N Gu Sn N Lantern bracket S ast iron GJL N Ipeller ast iron ronze GJL N Gu Sn N
More informationSpherical Roller Bearings Units: Rexnord PT Select Series
Spherical Roller earings Units: Rexnord PT Select Series Contents Page eatures and enefits 192 Nomenclature 193 Engineering 194 Dimensions Pillow locks 198 lange locks 202 Industries Served Aggregates
More informationISO Standard Hydraulic Cylinder
ISO Standard ydraulic ylinder Series S/SG Series S Q N Nominal pressure: S Pa ore size :,,,, Related quipment Series SG Nominal pressure: - Pa ore size : 3,,,,, 51 ISO Standard ydraulic ylinder Series
More informationQuality in vibrators. Pneumatic vibrators for industries. Conveying Filling Compacting Separating. data
Quality in vibrators Pneumatic vibrators for industries a.com l chnica e T d e l Detai indev f. w w :w data Conveying Filling Compacting Separating Findeva AG Loostrasse 2 CH-8461 Oerlingen Switzerland
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationN N O V A T I O N E F F I C I E N C Y Q U A L I T Y
N N O V A T I O N E F F I C I E N C Y Q U A L I T Y PS For more than 60 years the name Ruhrpumpen has been synonymous worldwide with innovation and reliability for pumping technology Ruhrpumpen is an innovative
More informationPARALLEL SHAFT DRIVES
ARALLEL SAT RIVES Introductory Information.................................................-2 re-selection Information................................................-3 Quick Selection Tables....................................................-4
More informationNEMA Premium Efficiency T-Frame Motors. Three-Phase, TEFC Enclosures RELIABILITY MATTERS
NEMA Premium Efficiency T-Frame Motors Three-Phase, TEFC Enclosures RELIABILITY MATTERS RELIABILITY MATTERS Aurora Motors a leading global supplier of NEMA premium vertical pump motors and T-frame motors
More informationMAC / MAD series MAC SHOCK ABSORBERS. Order example. TUBE O.D. (mm) STROKE (mm) Select damping constant from graph
M / MD series SHOK SORRS Order example M 0806 1 TU O.D. MD: djustable M: Non-adjustable MD: Double cushion STROK Select damping constant from graph 1: Hight : Medium 3: Low S: -S series K: -K series lank:
More informationTAL TAL TAL 049
TL 046 - TL 047 - TL 049 Low Voltage lternators - 4 pole 180 to 0 kv - 50 Hz / 225 to 1250 kv - 60 Hz lectrical and mechanical data TL 046 - TL 047 - TL 049 dapted to needs The TL alternator range is designed
More informationHigh Efficiency Direct Drive Fans
igh Efficiency Direct Drive ans 96 899 99s or over a century... istory Originally formed over years ago within the US based Torin orporation, and established as its U subsidiary in 96. Torin-Sifan has
More informationPresentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508
Presentation, pplication Severe uty Limit Switches 0 onforming to NEM 600 and UL508 escription 9007T Mill Switches Use the 9007T Mill switches instead of other limit switches in the following applications:
More informationSelection of Gear Box
orm Speed educers Selection of ear ox or ood performance of ear ox, The right selection is very important. The ear Unit Selection is made by comparing actual transmitted loads with catalogue ratings are
More informationHusky 1050e Pumps Electric Double Diaphragm
usky 15e Pumps lectric ouble iaphragm Selector Tool To order a usky 15e, use the online selector tool at www.graco.com/pumpselectors or contact your distributor. NOT: heck the identification plate (I)
More informationWork supports - Collet-Lok design
ork supports - ollet-ok design Shown: PS-1, PTS-1 Hydraulically locked, mechanically maintained work support ollet-ok products ollet-ok design allows the work support to maintain support position after
More informationCAplus Totally Enclosed Fan Cooled Motor
plus Totally nclosed Fan ooled Motor www.nidec-industrial.com industrial solutions Introduction fact or fiction? Total cost of ownership adds value. FT. nergy consumption and maintenance expenses are important
More informationMODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC
MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC ... 3... 4 3000 rpm 50 Hz / 3600 rpm 60 Hz... 4... 5... 7 Modular pump / motor systems... 7 Materials...........................................................
More informationWaterPumps QH QV QVK
WaterPumps Q QV QV Introduction IRON Pump /S was founded in 10 and since then the company has manufactured a great variety of pumps covering both the marine and industrial markets. Through the years the
More informationMTF. Technical features
Technical features Power supply Three-phase voltage from 24V to 690V, 50Hz or 60Hz or 100-130V, 60Hz and 200-240V, 50Hz ( types are supplied without capacitor); suitable for use with an inverter from 20Hz
More informationAC motors. 3/2 Overview
/ Overview / synchronous (induction) motors / forced-ventilated, degree of protection IP / PL motors forced-ventilated, degree of protection IP /4 Selection guides /4 dditional data for PH7 and PL motors
More informationExplosion proof electric motor For Fuel dispensing application. Main characteristic
Ad-pe ed.2018/0 1 Explosion proof electric motor For Fuel dispensing application RAEL motori elettrici, since its inception in the late 60s, has assembled more than a million of explosion proof electric
More informationX=ATEX BUTTERFLY VALVES + SA & NA ACTUATOR
B. V. E page 9 0409 AD E page 13 Ambient temperature -15 C / +70 C NBR 1147 316 SS NBR carboxyle 1149 1150 1151 316 SS GS cast iron 316 SS EPDM CH. EPDM NBR 1152 1153 GS cast iron 316 SS NBR EPDM 1154
More informationSpecialty Bearing Interchange Guide
pecialty earing Interchange uide Only one name is synonymous with the finest-quality mounted tapered and spherical roller bearings, aldor odge. We are the standard against which all other bearings are
More informationMotorized Pulley 400L, 400M & 400H, Ø 400 mm
otorized Pulley 400, 400 & 400, Ø 400 mm To match your requirements in diameter 400 mm, our product range offers three different loading performances for your BU applications: - for ight-duty - for edium-duty
More informationHigh-Performance Vibrators
esignation Power Supply K Three-phase S Single-phase Type Standard model igh-frequency model Stainless steel S surface Version Previous ew K - 1-2 ounting method Blank Standard lange-type V (Vertical model)
More informationHeliFlow Industrial Series. Positive Displacement Blowers & Vacuum Pumps
HeliFlow Industrial Series Positive Displacement lowers & Vacuum Pumps 2 GD HeliFlow uilt y the Industry Leaders GD HeliFlow HeliFlow integrates proven experience with blower design and manufacturing techniques
More information09/2012 Submersible Pumps
GM Subersible Pups 3 24 GM Subersible Pups GMV with vortex ipeller in cast iron N-GJL-2 pag. 2 GMVS with vortex ipeller in cast iron with polyurethane coating pag. 2 GM GMN with single channel ipeller
More informationROOF SPECIALIZED WORK LIGHTS FOR EXPLOSIVE AREAS
X ROOF SPECIALIZED WORK LIGHTS FOR EXPLOSIVE AREAS 01 INNOVATIVE EXPLOSION PROOF LED WORK LIGHTS SCANGRIP is first-mover when it comes to development of new and innovative LED work lights. Now, we are
More informationNon-Standard Motors Overview. Low-Voltage. IEC Squirrel-Cage Motors Frame sizes 315 to 450 Power range 160 kw to 1250 kw
Non-Standard Motors Overview MOTORS Low-Voltage IEC Squirrel-Cage Motors Frame sizes 15 to 450 Power range 160 kw to 1250 kw Non-standard motors frame size 15 and above Overview N compact three-phase asynchronous
More informationModel ZW204 Non-Modulating Float Valve
Model Z04 Non-Modulating loat Valve pplication The Zurn ilkins Model Z04 Non-Modulating loat Operated ontrol Valve is designed to be either fully open or fully closed in response to the position of the
More informationIE4. NEMA Super Premium Efficiency Motor AEHH4E SERIES
4 Super remium fficiency otor HH4 SS Super remium (4) efficency ow ibration ow oise SF S F Kind of otors esign Standards oltages Frequency utput ange... (Syn.) ime uty Frame Size rotection nclosure ooling
More informationLow Center Motors Catalogue
ow Center otors Catalogue E dynamic, strong and ambitious roup: Orange1 olding is an international renown roup, one of the most important European manufacturers of single-phase and three-phase asynchronous
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview.
Level Measurement Pointek LS200 Standard Siemens A 20 Overview onfiguration Installation Pointek LS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable
More informationSOLENOID VALVES direct operated, basic flow balanced poppet 1/4
SONOI VVS direct operated, basic flow balanced poppet /4 U / Series 7 TURS The valves are certified according to I 6508 unctional Safety data and have SI- capability (TÜV & xida certification) The solenoid
More informationCALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function
Mixing valves and actuators 610-611 - 612-63 series RIT ISO 01 M 214 LI 01169/17 replaces dp 01169/09 unction The mixing valves allow the centralisation heating system to be regulated by mixing the boiler
More informationSD SERVO MOTOR. General Data
General Data S series of rare earth 3 phase permanent magnet servo motors was conceived and designed as an advanced and homogeneous range of high performance servo actuators, in line with the evolving
More informationQuick and Easy Voltage Flexibility for NEMA and Metric IEC Motors Motors are re-rated from stock models to 575V in as little as (1) business day
Elektrim 7V s Quick and Easy Voltage Flexibility for NEMA and Metric IEC s s are re-rated from stock models to 7V in as little as () business day Available 7V s: -0 HP NEMA Premium Performance Series s
More informationHypra and P 17 industrial sockets
[ INUSTRIL SOKTS ] Products and systems ypra and P 17 industrial sockets 2 ranges cover 3 levels of weatherproofing: IP 44, IP 66/67 and IP 66/67-55: ypra is recommended for harsh environments (dust, water
More informationStationary Portable Compressors. MOBILAIR M 57 Utility / M 58 Utility With the world-renowned SIGMA PROFILE Flow rate 4.35 to 5.
Stationary Portable Compressors MOBILAIR M 57 Utility / M 58 Utility With the world-renowned SIGMA PROFILE Flow rate 4.35 to 5.4 m³/min www.kaeser.com M 57/58 Utility In many cases, ready-access to a permanent
More informationGeneral Characteristics
from 63 to 31 lbs_037_b he solution for > ain switchboard > Distribution panel > mergency switching > us tie unction he L ensures making and breaking on load and security breaking of any low voltage electrical
More informationMOBILAIR M 350. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 24.0 to 34.0 m³/min (850 to 1200 cfm)
MOBILAIR M 350 Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 24.0 to 34.0 m³/min (850 to 1200 cfm) www.kaeser.com MOBILAIR M 350 The powerful combination of the highly efficient
More informationSOLENOID VALVES direct operated, basic flow balanced poppet 1/4
SONOI VVS direct operated, basic flow balanced poppet /4 U / Series 7 TURS The valves are certified according to I 6508 unctional Safety data and have SI- capability (xida approval) The solenoid valves
More informationSpiraflo Steam flowmeters
Spiraflo Steam flowmeters Using a Spiraflo steam meter from Spirax Sarco will enable you to measure steam use accurately under all load conditions. It will provide vital information on usage and associated
More informationCOMPRESSORS MOBILAIR M 115. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 7.5 to 11.5 m³/min ( cfm)
COMPRESSORS MOBILAIR M 115 Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 7.5 to 11.5 m³/min (265 405 cfm) www.kaeser.com MOBILAIR M 115 The powerful combination of the highly efficient
More informationISO Standard Hydraulic Cylinder
IO tandard ydraulic ylinder eries / eries eries Nominal pressure: a ore size :,,,, Q N Related quipment - Nominal pressure: a ore size : 3,,,,, 4 IO tandard ydraulic ylinder eries Nominal pressure a/ a
More informationBareshaft Blowers S2H Two Lobe Series
Bareshaft s S2H Two Lobe Series S2H Series s Range Range of positive displacement blowers featuring two lobes for use in compression and vacuum for air or neutral gases. Pressure up to 1 bar (14.5 psig)
More informationElectronic Temperature Control & Bulb Well Assembly (AC)
Electronic Temperature ontrol & ulb Well ssembly () 0916 86816 This is a line voltage single-stage electronic temperature control with singlepole, double-throw relay output and LED indication. It is designed
More informationWorldwide, our pumps get the job done. Corporate Headquarters North America, South America, Asia and Australia Sales
Mining 3/4-10 Tapped Hole D Hole C Pioneer pumps built with heavy-duty drag skids handle the extreme pressures required in the mining industry, with capabilities up to 700+ feet (210m) and flows to 18,000
More information3.6 to 125.9cm 3 /rev 30MPa
P SRS P PUP P Series P Pump 3.6 to 1.9cm 3 /rev 3Pa This is a new design series in which all pump types are installation compatible with previous designs. ote, however, that there is no longer compatibility
More information3/2 ^ % Features. Construction. Electrical
4 Pilot Operated Spool Valves xplosionproof Solenoid Valves 316L odies 1/4" NPT 3/2 SRIS 364 eatures Ideal for oil and gas control panel applications rop-in replacement design - compatible with most existing
More informationThree-PhaseVacuumCONTACTORS RP173. Features
Three-PhaseVacuumOTTORS RP173 easuring 18" x 18"W x 8" and weighing less than 67 lbs., the ennings RP173 Three-Phase Vacuum ontactor is built tough to work in a variety of heavy-duty applications. ble
More informationHigh Pressure Valves, Fittings and Tubing Pressures to 65,000 psi
igh Pressure Valves, ittings and Tubing MXMTOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed
More informationUnimotor. Control Techniques Dynamics. Brushless.. AC Servo. Motors...
Unimotor rochure ontrol Techniques ynamics rushless Servo Motors UNIMOTOR haracteristics Introducing Unimotor Unimotor is a range of brushless servo motors from T ynamics They are three phase, 6 or 8 pole,
More informationRPP Medium range pressure switches
RPP Medium range pressure switches ll industrial environments ll fluids One or two thresholds ll stainless steel version for aggressive environments French lectricity Generating Board (F) electronuclear
More informationOdor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange
fficiently can remove odor in compressed air with an activated carbon element. The unit is designed for use in the area such as a clean room where odors must be avoided. an remove odor and gas ingredients
More informationK E E Model Designation. Ambient Environment. Safety Precautions
esignation Power Supply Type Version K - 1-2 ounting method force ote 4 of poles Additional code Special Specifications Ambient nvironment otes: 1. This table shows how to read the model numbers of standard
More informationGear Drive Solutions a Dedicated and Reliable Partner
Gear Drive Solutions a Dedicated and Reliable Partner /// Gears, spindle gears, actuators, motors etc. /// Flange bearing and pillow block bearing units /// Standard or customized products /// Complete
More informationOpen, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts
0.- Motor Starters & ontactors Low Voltage Lighting ontactors lectrically eld N January 00 Sheet 18 0 1 7 8 0 1 7 8 0 N-Open (L0-nclosed) 0 mpere 0 mpere Product escription Lighting ontactors are designed
More informationWorm Gear Hand Winches Up to 4000 lb capacity
IO 900 ertified Worm Gear and Winches Up to 4000 lb capacity achine ut Worm Gears provide accurate operation and long lasting service. nclosed Oil ath provides continuous lubrication of gears to minimize
More informationA robust, pilot operated solenoid valve for direct mounting to pneumatic actuators Figure 79E/79U and PremiAir.
VI F79N Namur Solenoid Valve robust, pilot operated solenoid valve for direct mounting to pneumatic actuators Figure 79E/79 and Premiir. Features ompact design with standardized market proven NMR mounting
More informationSuperior electrical performance benefits, unsurpassed reliability :
series : ombining over 100 years experience with innovative new technology makes the series the right choice for the demanding needs of today's industry. uperior electrical performance benefits, unsurpassed
More informationLinear Valve Electric Actuator
Linear Valve Electric Actuator www.powervalves.nl Company Profile Company Profile Sun Yeh Electrical Ind. Co., Ltd. was founded in 1986. We always strive for technical excellence, innovation and the highest
More informationP2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets
P2 : About Us P3 : Elsewedy Transformers P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers P7 : Technical Data Sheets P8 : Transformer s Outline Drawing P9 : Accessories About Us
More informationGeneral Purpose Energy Efficient Induction Motors series 2SIE
General Purpose Energy Efficient Induction Motors series 2SIE Comply with the new efficiency classes for low-voltage three-phase motors IEC 60034-30 standard and EU Regulation 640/2009 Product Catalogue
More information2/2. Air or Water Pilot Operated Angle Body Multi-Purpose Valves. Bronze or 316L Stainless Steel Bodies 3/8" to 2 1/2" NPT.
4 Air or Water Pilot Operated Angle ody Multi-Purpose Valves ronze or 36L Stainless Steel odies 3/8" to 2 /2" NPT 2/2 SRIS 82 The 82 Series consists of 2-way direct acting valves available in normally
More information