Filled System Thermometers
|
|
- Rebecca Chase
- 6 years ago
- Views:
Transcription
1 illed System Thermometers Model N & NR Mechanical Thermometers ata sheet : ST/2012 The Rototherm range of filled system thermometers offer tough yet accurate instruments with rigid stems for direct mounting or with flexible capillary for remote reading. Most models in the range may be specified with electrical contact heads to provide alarm or control functions. Rototherm non toxic filled system thermometers are designed to give guaranteed reliability over a wide range of ambient temperature conditions and are compensated for ambient temperature changes from - to +50º. N1 & N2 Thermometers Where display is required some distance from the sensing point, for example on an instrument panel, capillary thermometers should be used. The dial can be located up to metres from the sensing point and isolated from dirt and vibration. The sensing bulb is connected by stainless steel microbore capillary, protected by stainless steel tubing. or severe conditions, flexible armour can extend the entire length of the capillary. lternative protections can be specified if required. Specifications - N1 & N2 Thermometers ase & ezel N1 iecast luminium. N2 4 stainless steel. 316 stainless steel option. ial learly marked black characters on white background lass as standard. Options - acrylic and toughened glass. ulb / Stem 316 stainless steel Microbore stainless steel tube with 3mm O stainless steel protection. Maximum capillary Length metres (for as filled instruments) 12 metres (for ylene filled instruments) See table for standard temperature ranges ccuracy lass 1.0 (±1.0% S) (±2% when electrical contact heads are fitted) mbient Temperature Head compensated for variation in ambient temperature from - to +50º. Models N1 eneral Purpose capillary Thermometers Tough accurate thermometers housed in a gasket sealed diescast aluminium case. N2 Stainless Steel ased Thermometers Reliable, accurate industrial thermometers housed in a stainless steel case with the option of 100mm or 160mm diameter dial N1 42 N1 46 N2 42 N2 48 N2 62 N2 66 N mm ial, Surface Mounted ottom ntry 100mm ial, Panel Mounted ack ntry 100mm ial, Surface Mounted ottom ntry 100mm ial, Panel Mounted ack ntry 100mm ial, racket Mounted ottom ntry 160mm ial, Surface Mounted ottom ntry 160mm ial, ial Panel Mounted ack ntry 160mm ial, racket Mounted ottom ntry NR1 eneral Purpose Thermometers Tough accurate thermometers housed in a gasket sealed glass filled polyester resin case with adjustable zero. Instruments can be configured as vertical or horizontal mounting. NR2 Stainless Steel ased Thermometers Reliable, accurate industrial thermometers housed in a stainless steel case with the option of 100mm or 160mm diameter dial. NR1 42 NR1 46 NR2 46 NR2 62 NR mm ial, ottom ntry 100mm ial, Lower ack ntry 100mm ial, ottom ntry 100mm ial, Lower ack ntry 160mm ial, ottom ntry 160mm ial, Lower ack ntry xcellence the World can Measure TM
2 Specifications - NR1 & NR2 ase & ezel NR1 lass filled polyester resin, non toxic, fire retardant, black. NR2 4 stainless steel. 316 stainless steel option. ial learly marked black characters on white background lass as standard. Options - acrylic and toughened glass. Stem 316 stainless steel See table for standard temperature ranges Stem imensions 12.7mm diameter (other non standard diameters are available on request) Standard stem lengths 200mm, 0mm, 400mm and 500mm. Sensitive length depends on temperature range and filling medium and is indicated by shallow waisting. ccuracy ±1.0% S (±2% when electrical contact heads are fitted) mbient Temperature Head compensated for variation in ambient temperature from - to +50º. Movement irect acting bourdon tube with bimetallic compensator. Option silicone damped Standard s - N1, N2, NR1 & NR2 pproximate Sensitive Length - imension 12.7 mm bulb / stem diameter egree egree ylene Non Toxic illing Nitrogen Non Toxic illing - to +70 º -20 to 160 º mm Not available 0 to 60 º to 140 º 40 mm Not available 0 to 100 º to 220 º mm Not available 0 to 120 º to 250 º mm Not available 0 to 160 º to 0 º 25 mm Not available 0 to 200 º 50 to 400 º 25 mm 125 mm 0 to 0 º 0 to 550 º Not available 125 mm 0 to 400 º 0 to 700 º Not available 125 mm Other non standard ranges may be available - please check with Rototherm sales ulb Types - Models N1 & N2 This bulb type is used when no compression fitting is required. This bulb may be held in place by a bracket or clip (not supplied by Rototherm) or may inserted directly into the process. This bulb has a compression gland fitting that slides along the capillary and is tightened into the required position. This bulb type is only available with plain stainless steel capillary (type 1) - armoured capillaries are not available as it is not possible to move the fitting along the armoured capillary. ulb length cannot be specified. ompression gland fittings tighten on the bulb to provide liquid and gas tight seal. Once fitted the position of the gland fitting can only be altered by cutting off the olive and replacing it with a new one. If required this bulb type may be specified with a compression gland fitting - in this instance please confirm the required overall length of the bulb. this length is adjustable sensitive portion this length is adjustable
3 imensions NR imensions NR2 º º imensions N2 º Length in Metres 3 holes K diameter on p.c.d. L = Stem Length = ulb/stem sensitive length Length in Metres ll dimensions are in mm. rawings are for illustration purposes only. imensions ack lange Panel Mounting racket Mounting irect Mounting 100mm 160mm 100mm 160mm 100mm 160mm 100mm 160mm Panel ut Out Weight 1.2 kg 1.8 kg 1.2 kg 1.8 kg 1.2 kg 1.8 kg 1.2 kg 1.8 kg K L lectrical ontact Heads (Model N2 & NR2 only) To provide alarm or control functions, filled system thermometers can be specified with electrical contact heads mounted in a clear plastic hood which replaces the standard window. The set point can be adjusted to any position on the scale with a removable key. Single and dual contacts systems are available. lectrical contact heads provide a repeatable switching point, but the absolute accuracy tolerance of the instrument is approximately doubled by the contacts. ontact Rating Standard contact head assemblies: 250V, switching capacity 10W, 18V, maximum current 0.7. Service Indoor use, ambient temperature -10/70º, free from vibration. System Operation reak on rise Make on rise 2 ontacts to break on rise in temperature 2 ontacts to make on rise in temperature reak on rise and make on rise in temperature Typical pplication Temperature control Over temperature alarm Temperature control plus alarm or 2 step pressure control larm and trip ll dimensions are in mm Temperature control plus alarm
4 Order ode - illed System Thermometers N1 iecast luminium ase 100 mm dial, back entry N1 42 N1 46 N2 Stainless steel ase 100 mm dial, back flange, bottom entry 100 mm dial, panel clamp, rear entry 100 mm dial, bracket mounting, bottom entry 160 mm dial, back flange, bottom entry 160 mm dial, panel clamp, rear entry 160 mm dial, bracket mounting, bottom entry N2 42 N2 48 N2 62 N2 66 N2 68 lass (Standard) crylic ulb Type Protection Stainless steel tube, 3.0 mm diameter Stainless steel flexible armour, 6.3 mm diameter Stainless steel flexible armour over stainless steel, 6.3 mm diameter Other (state requirement) Length Insert length in metres (3 metres is standard) Insert temperature range and units from table ompression land itting (type 2 & 3 bulbs only) Not required 1/2 SP male, stainless steel 3/4 SP male, stainless steel 1/2 NPT male, stainless steel Other (State Requirement) Pointer Options & lectrical ontact Heads lectric contact type (N2 models only) lectric contact type (N2 models only) lectric contact type (N2 models only) lectric contact type (N2 models only) lectric contact type (N2 models only) Maximum pointer Minimum pointer Index pointer No electric contact or additional pointer H xample Order ode - Thermometer º Model, 100mm capillary thermometer, panel clamp mounting, glass window. bulb with 3 metres of type 1 stainless steel capillary. Temperature range 0 to 60º, 1/2 SP male stainless steel gland. No additional pointer or options.
5 Order ode - Rigid Stem illed System Thermometers N1 lass illed Polyester Resin ase 100 mm dial, back entry NR1 42 NR1 46 N2 Stainless steel ase 100 mm dial, ear entry 160 mm dial, bottom entry 160 mm dial, rear entry NR2 46 NR2 48 NR2 62 lass (Standard) crylic Stem length Insert stem length in mm Insert temperature range and units from table ompression land itting Not required 1/2 SP male, stainless steel 3/4 SP male, stainless steel 1/2 NPT male, stainless steel Other (State Requirement) Pointer Options & lectrical ontact Heads lectric contact type (N2 models only) lectric contact type (N2 models only) lectric contact type (N2 models only) lectric contact type (N2 models only) lectric contact type (N2 models only) Maximum pointer Minimum pointer Index pointer No electric contact or additional pointer H xample Order ode - Rigid Stem Thermometer 150mm 0-60ºc Model, rigid stem thermometer 100mm dial bottom entry, glass window. Stem length 150 mm. Temperature range 0 to 60º, 1/2 SP male stainless steel gland. Single electric contact - type, make on rise in temperature. TM ISO9001:2008 ritish Rototherm ompany Limited Kenfig Industrial state, Margam, Port Talbot S13 2PW United Kingdom xcellence the World can Measure TM T: +44 (0) : +44 (0) : sales@rototherm.co.uk W: In keeping with ritish Rototherm s policy for continual product development and improvement, we reserve the right to amend specifications without notice Rototherm roup. ll rights reserved. ompany registered in Wales : Registered office as above.
Clearscan C105 & M105 Pressure & Temperature Recorders
Clearscan C05 & M05 Pressure & Temperature Recorders Choice of Cases This range of temperature and pressure recorders can be built into either of two types of tough steel case. oth have a lockable fronthinged
More informationCLEARSCAN MECHANICAL RECORDER
Data Sheet CLEARSCAN MECHANICAL RECRDER Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Process Recorders Clearscan Mechanical Recorder Flow, Pressure & Temperature Model CLEARSCAN
More informationGT All SS Industrial Dial Thermometer Gas Filled system
TM ll SS Industrial Dial Thermometer Gas Filled system Special Features approved electrical contacts. Inert gas filled expansion system. Stainless steel case & stem With or without thermowell Silicon oil
More informationMineral Insulated Resistance Thermometers (RTD)
Mineral Insulated Resistance Thermometers (RTD) Electronic Temperature Measurement Data sheet : MIRTD/2012 Contents Page RTD Element Type 2 Conductors & Number of Wires 2 Probe Diameter 3 Length Types
More informationDigiTemp. Digital Thermometer
DigiTemp R Digital Thermometer (Standard Version) Page 1 The DigiTemp battery-powered digital thermometer is designed to suit a wide range of industrial applications which demand accurate measurement of
More informationClass 1 as per EN o C to 65o C 15 kg/cm2 ( without thermowell ) 120 % of Full Scale 8 mm ½ BSP (M) Adjustable
Special Features & tex approved electrical contacts. Inert gas filled expansion system. Stainless steel case & stem With or without thermowell Silicon oil filled (optional) Standard followed EN 90. pplication
More informationTHERMOMETERS FOR TRANSFORMERS
THERMOMETERS FOR TRANSFORMERS GENERAL DESCRIPTION This instrument measures the insulating oil in the transformer. They are studied for withstanding to the most adverse process conditions due to the aggressiveness
More informationTSS Gas filled thermometer
Main Features For corrosive gasses and liquids Class 1 according to EN 13190 Wetted parts and case material stainless steel Option: case material 1.4404 (316L) for aggressive atmosphere pplications Food
More informationWP4 All SS (SS 304) Pressure Gauge Bourdon type
pecial Features xternal zero adjustment (optional) tainless steel case & measuring system ocket directly welded to case Dry and liquid filled version tandard followed N 837- (for N 00, & 0 mm) C marking
More informationGas Actuated Thermometers Stainless Steel Series, Model 73
Mechanical Temperature Measurement Gas Actuated Thermometers Stainless Steel Series, Model 73 WIKA Data Sheet TM 73.01 Applications For aggressive media in the chemical, petrochemical and process engineering
More informationWP6 All SS (SS 316 Wetted Parts ) Pressure Gauge Bourdon type
pecial Features xternal zero adjustment (optional) tainless steel case & measuring system ocket directly welded to case Dry and liquid filled version tandard followed N 837- (for N 00, & 0 mm) C marking
More informationSAMPLE PRODUCT SPECIFICATIONS
SAMPLE PRODUCT SPECIFICATIONS Thermometers & Gauges Product Guide Specification THERMOMETERS & GAUGES Specifier Notes: This section covers Miljoco Corporation thermometers and pressure gauges suitable
More informationDial thermometers. Gas filled system and Bi-metal. dial thermometers
JJ Dial thermometers JJ Diesel engine thermometers JJ Low temperature dial thermometers JJ Remote reading dial thermometers JJ Remote reading diesel engine thermometers JJ Remote reading low temperature
More informationCALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function
Mixing valves and actuators 610-611 - 612-63 series RIT ISO 01 M 214 LI 01169/17 replaces dp 01169/09 unction The mixing valves allow the centralisation heating system to be regulated by mixing the boiler
More information300/400/ /900 SERIES
Dial Indicating Thermometers Vapor Actuated Remote 300/400/600 700/900 SERIES Indicates media temperature using a temperature-actuated liquid in the sensing element and a highly accurate, high quality
More informationLiquid filled Thermometers
Liquid filled Thermometers Description and general specifications Liquid filled contact thermometers Operating instructions and maintenance Finished product quality control tests 02 02 05 06 1 Description
More informationBimetal Thermometers Process Industry Series, Model 55
Mechanical Temperature Measurement Bimetal Thermometers Process Industry Series, Model 55 WIKA Data Sheet TM 55.01 Applications Chemical industry, petrochemical industry, process technology and food industry
More informationMODEL RTO FILLED SYSTEM TEMPERATURE RECORDERS, RPO PRESSURE RECORDERS & RECORDERS CONTROLLERS (ELECTRICAL CONTROL) Instruction Manual
MODEL RTO FILLED SYSTEM TEMPERATURE RECORDERS, RPO PRESSURE RECORDERS & RECORDERS CONTROLLERS (ELECTRICAL CONTROL) Instruction Manual Introduction 1 Specification 1 Description of Operation 1 Receipt of
More informationBimetal Thermometers Model 54, Heavy Duty Series
Mechanical Temperature Measurement Bimetal Thermometers Model 54, Heavy Duty Series WIKA Data Sheet TM 54.01 Applications T Universally suitable for plant, machinery, tank and apparatus construction T
More informationTBM. Bi-Metal Thermometer
Description & Features: A general purpose, versatile 1" (25mm) to 6" (150mm) dial, 304 stainless steel thermometer Bi-metallic sensing element for reliable readings Back, bottom or adjustable angle connection
More informationGas-actuated thermometer Model 73, stainless steel version
www.materm.si tel: 02 608 90 10 Mechanical temperature measurement Gas-actuated thermometer Model 73, stainless steel version WIKA data sheet TM 73.01 Applications For aggressive media in the chemical,
More informationEGT SS Case Internal Brass Pressure Gauge Bourdon type (Two Part Connection System)
GT Case Internal rass Pressure Gauge ourdon type (Two Part Connection ystem) pecial Features tainless steel case & rass measuring system Rugged construction Dry or liquid filled tandard followed in general
More informationRemote reading dial thermometers, version for industry
Remote reading dial thermometers, version for industry Type 313 WH, 323 TA, 333 TE and 334 KL Measuring system Nitrogen filled Type 313 WH Accuracy (EN 13190) Class 1 Case Crimped-on ring, stainless steel
More informationINDUSTRIAL THERMOMETER
INDUSTRIAL THERMOMETER The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies. Trafag Industrial Components complement the genuine
More informationINDUSTRIAL THERMOMETER
INDUSTRIAL THERMOMETER The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies. Trafag Industrial Components complement the genuine
More informationTBM. Bi-Metal Thermometer
Description & Features: A general purpose, versatile 1 (25mm) to 6 (150mm) dial, 304 stainless steel thermometer Bi-metallic sensing element for reliable readings Back, bottom or adjustable angle connection
More informationGas-actuated thermometer with switch contacts Model 73, stainless steel version
Mechatronic temperature measurement Gas-actuated thermometer with switch contacts Model 73, stainless steel version WIKA data sheet TV 27.01 for further approvals see page 12 Applications Control and regulation
More informationBimetal thermometers Index
Inex eneral information Prouct information With brass pocket page Inex 685 Brass pocket; Aluminium case 686 Brass pocket; 687 With brass probe page Brass probe; Aluminium case; Air uct thermometer 688
More informationLevel Measurement Point level measurement - Vibrating switches
Siemens G 2018 SITRNS LVS200 Overview SITRNS LVS200 is a vibrating point level switch for high, low, or demand level detection of bulk solids. enefits High resistance to mechanical forces Strong vibration
More informationSteam & Hot Water INSTRUMENTS. Adjustable Angle Industrial Thermometer. Econo Thermometer. ] Aluminum Stem. ] Air-Duct Stem
Adjustable Angle Industrial Thermometer Recognized globally as the Trerice BX Industrial Thermometer, this is an instrument of extreme accuracy and rugged dependability. Available in scale lengths of 7"(AX),
More informationRD Standard differential pressure switches
R Standard differential pressure switches Pneumatics or hydraulic fluid control Power generation safety equipments Pressurized chambers control Level measurement onforms to These instruments compare a
More informationPart Number Code of Pressure Gauge
Part Number ode of Pressure auge x x x - x x x asic Instrument Type 0=pecial 1=ourdon Tube/tandard =ourdon Tube/Industry 3=ourdon Tube/Test 4=iaphragm 5=larm ontacts 9=Mechanical ccessories etted parts
More informationLevel Measurement Point level measurement - Rotation paddle switches
Siemens 017 SITRNS LPS00 Overview SITRNS LPS00 is a rotary paddle switch for point level and material detection in bulk solids. enefits Proven paddle switch technology for bulk solids High integrity mechanical
More informationZEAL The Gauge of Quality PRECISION BIMETAL DIAL THERMOMETERS
ZEAL The Gauge of Quality PRECISION BIMETAL DIAL THERMOMETERS TRADE CATALOGUE 2005 ZEAL The genuine article since 1888 Distributer : ANSARI AGENCIES SDN.BHD. 18-A, 1st Floor, Jalan MJ/ 7, Medan Maju Jaya,
More informationHEPA terminal filter units Ceiling diffusers: F640, F650, F654, F655, F656, F659, F660 Wall grilles: F670
HPA terminal filter units eiling diffusers: 60, 650, 65, 655, 656, 659, 660 Wall grilles: 670 or critical air purity and hygiene requirements Used in medicine, biology, pharmaceuticals, and sensitive technical
More informationEEA & EEB Series. UL Recognized CSA Certified VDE Approved EEA2 / EEB2
atalog: 16541 Issue ate: 6.11 Including the S/S and H/H Models ost-effective MI Power Inlet Filter UL Recognized S ertified V pproved 2 / 2 1 / 1 P / P Series ompact single stage MI filter with I 63-1
More informationPresentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508
Presentation, pplication Severe uty Limit Switches 0 onforming to NEM 600 and UL508 escription 9007T Mill Switches Use the 9007T Mill switches instead of other limit switches in the following applications:
More information1 (25mm): Acrylic Others: Glass standard, hermetically sealed
Description & Features: A general purpose, versatile 1" (25mm) to 6" (150mm) dial, 304 stainless steel thermometer Bi-metallic sensing element for reliable readings Back, bottom or adjustable angle connection
More informationISO Standard Hydraulic Cylinder
ISO Standard ydraulic ylinder Series S/SG Series S Q N Nominal pressure: S Pa ore size :,,,, Related quipment Series SG Nominal pressure: - Pa ore size : 3,,,,, 51 ISO Standard ydraulic ylinder Series
More informationTC-200 Series. Application. Features. Applicable Literature. Single Bulb Thermostats General Instructions
T-200 Series Single ulb Thermostats General Instructions Application These units are used for on-off control of media temperature in ducts, tanks, etc. Features Mechanism enclosed in rugged die cast case
More informationWhen ordering, please state type and code number. Suitable sensor length. Max. Cap. range. tube adjust- see also Accessories. sensor. temp.
Thermostats Description KPS thermostats are temperature-controlled switches. The position of the contacts depends on the temperature of the sensor and the set value. In this series, special attention has
More informationTSSE Gas filled thermometer with contacts
Main Features For corrosive gasses and liquids Class 1 according to EN 13190 Wetted parts and case material stainless steel Mechanical or inductive contacts Option: case material 14404 (316L) for aggressive
More informationGas-actuated thermometer with switch contacts Stainless steel version Model 73
Temperature Gas-actuated thermometer with switch contacts Stainless steel version Model 73 WIKA data sheet TV 27.01 for further approvals see page 12 Applications Control and regulation of industrial processes
More informationPHENOLIC MOTOR PROTECTORS
PHNOI MOTOR PROTTORS WHY PROTT MOTORS? Overheating of motor insulation causes reduction in dielectric strength which can result in motor insulation damage or failure. The following are causes of motor
More informationRotary actuator Rack & pinion type. Size: 8, 32, 63 Oscillating angle: 90, 180,
G V* H FH HP S2 H/ LH LHG HL/ HLG/ G HL HM G S *H H2 L2 N/ S/F Specifications escriptions Size ffective torque Note 1 N m ctuation Working fluid Max. working pressure MPa Min. working pressure Note 2 MPa
More informationPowers Controls TT 184 Temperature Transmitters
Powers Controls Document No. 155-077P25 TT 184-1 Room Transmitter Remote Bulb Average Bulb Rigid Bulb Description The are direct acting, one-pipe instruments that sense temperature and transmit a proportional
More informationProduct Information / Order Code
Product Information / Order ode Order odes eries and Type low onitoring ystem G - 0.04 - - 1 - V - X G Version 0,002... 2 l/min / 0.0005... 0.53 U GP 0.02 0,004... 4 l/min / 0.0011... 1.06 U GP 0.04 0,01...
More informationProduct Catalog. Our Products. DCI Dynamic Instruments Website: dcidynamic.com
1 Product Catalog Our Products We at Dynamic are proud to present out new technical catalogue detailing our extensive range of Pressure Gauges, Thermometers, diaphragm seal, transmitter and accessories.
More informationMid-West Instrument. Bellows Type Differential Pressure Gauges & Switches Model s 105 & 106
Bellows Type Differential Pressure Gauges & Switches Model s 105 & 106 Dry Gauge Design with No Internal Liquid Fill BULLETIN NO. 105-106/12 (SUPERSEDES 105-106/11) Industrial ontrol Over Range Protection
More informationPressure controls and thermostats, type KPS
KPS pressure controls are fitted with a 3 mm steel mounting plate. The units should not be allowed to hang from the pressure connection. Pressure connection When fitting or removing pressure lines, the
More informationPNEUMATIC RACK AND PINION ACTUATORS. Advanced torque to size ratio
PNUMTI RK N PINION TUTORS dvanced torque to size ratio eatures: Pneumatic Rack and Pinion ctuators 90 ctuation for -way valves (Straight & ngle) 180 ctuation for -way (T-type) valves ctuators comply with
More informationSelf-Acting Temperature Control Valve
GLOE & NEELE Northeast ontrols Inc. Tel: 8454183435 Fax: 8455952471 www.dwyerstore.com Selfcting Temperature ontrol Valve Require No External Power Selfcting Temperature ontrol Valves require no external
More informationNEMA Contactors & Starters A200
March 007 NM ontactors & Starters 00 ontactors Non-reversing and Reversing -7 ontents escription Page ontactors Non-reversing and Reversing............ -7 Product escription Sizes 00 4............ -7 Product
More informationDimensions / Technical Data / Order Codes
Fluid Level / Temperature Indicators / / rder odes Level Gauge SN D Design of Scale Plates Thermometer ptions apillary Tube Thermometer with a dual elsius / Fahrenheit scale up to +80 / +80 F L3 YUR LG
More informationTBM. Bi-Metal Thermometer
Description & Features: A general purpose, versatile 1 (25mm) to 6 (150mm) dial, 304 stainless steel thermometer Bi-metallic sensing element for reliable readings Back, bottom or adjustable angle connection
More informationMSRT 150. Oil Temperature Indicator for Power Transformer type :
Oil Temperature Indicator for Power Transformer type : MSRT 150 Introduction Description and general specifications Options Operating instructions and maintenance Finished product quality control tests
More informationFlowmeter F I Gardex. Connection and installation instructions. Application. Benefits. Design and mode of operation
The baffle plate (b) causes a back-pressure in the medium, and the balance beam (c) is deflected. This movement is transmitted via the beam to the indicator mechanism (e) using a bellows bushing (d). gear
More informationGas-actuated thermometer Highly vibration resistant Model 75, stainless steel version
Mechanical temperature measurement Gas-actuated thermometer Highly vibration resistant Model 75, stainless steel version WIKA data sheet TM 75.01 for further approvals see page 5 Applications For the local
More information,, WY VLVS Way Valves - Side ntry Product index... p. - Way Valves - ottom ntry Product index... p. Way Valves - ottom ntry Product index...p. ontents
MTRI,, WY VLVS 6P/6P SRIS ,, WY VLVS Way Valves - Side ntry Product index... p. - Way Valves - ottom ntry Product index... p. Way Valves - ottom ntry Product index...p. ontents Introduction... Page - Product
More informationAir Actuated Ball Valves 3-Way T-Port Stainless Steel, Full Bore 1/4 to 2 NPT
ir ctuated all Valves 3-Way T-Port Stainless Steel, ull ore 1/4 to 2 SRIS eatures ull Port 3-way T flow path irect mount valve with standard ISO5211 mount 316 stainless steel body, ball and stem ctuators
More informationGauges and Thermometers
Technical Guide Gauges and Thermometers Pressure Gauges Thermometers Altitude Gauges Sprinkler Gauges Industrial Gauges Logo Gauges Ancillary Equipment Pressure Gauges Pressure gauges in this catalogue
More informationRPPN3 - RPPN7 Industrial pressure switch
Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Applications Energy safety equipment Power generation safety equipment Pressurized chambers
More informationISO Standard Hydraulic Cylinder
IO tandard ydraulic ylinder eries / eries eries Nominal pressure: a ore size :,,,, Q N Related quipment - Nominal pressure: a ore size : 3,,,,, 4 IO tandard ydraulic ylinder eries Nominal pressure a/ a
More informationBourdon Tube Type Differential Pressure Gauge & Switches Model 109
BULLETIN NO. 109/11 (SUPERSEDES BULLETIN NO. 109/05) Bourdon Tube Type Differential Pressure Gauge & Switches Model 109 LOKED LOGI LRM ONTROLS (vailable with 1 or 2 switches for alarm & control) Over Range
More informationOdor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange
fficiently can remove odor in compressed air with an activated carbon element. The unit is designed for use in the area such as a clean room where odors must be avoided. an remove odor and gas ingredients
More informationUnimotor. Control Techniques Dynamics. Brushless.. AC Servo. Motors...
Unimotor rochure ontrol Techniques ynamics rushless Servo Motors UNIMOTOR haracteristics Introducing Unimotor Unimotor is a range of brushless servo motors from T ynamics They are three phase, 6 or 8 pole,
More informationMESSKO COMPACT SERIES OIL TEMPERATURE ORDERING SPECIFICATIONS.
MESSKO COMPACT SERIES OIL TEMPERATURE ORDERING SPECIFICATIONS. M ES SKO INS TR U ME NTS MESSKO Compact Series - North America Version Type MT-ST160SK(TT) Oil Temperature Project/Reference: US probe 7RM
More informationCZ-200P PG500 PCT-300. General Description. Features. Resin Pressure Measuring System CZ-200P. Resin Pressure Sensor CZ-200P
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 P5 P5 5 Resin Pressure Measuring System Z-2P Z-2P P5 PT-3 eneral escription Resin pressure indicator P5 Resin pressure sensor : Z-2P Output converter : PT-3 RK's resin pressure
More informationBimetal thermometer with Pt100 electrical output signal Model 54, stainless steel version
Mechatronic temperature measurement Bimetal thermometer with Pt100 electrical output signal Model 54, stainless steel version WIKA data sheet TV 15.01 Applications Twin-Temp Machine building, plant and
More informationRDN4 - RDN8 Differential pressure switch
Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Applications Power generation safety equipment Pressurized chambers control Liquid level control
More informationBronze Gate Valves. SECTION 2a. Tel: +44 (0) Fax: +44 (0)
SETION 2a ronze Gate Valves Tel: +44 (0)1695 712800 Fax: +44 (0)1695 712820 Email: sales@hattersley.com export@hattersley.com www.hattersley.com ontents ronze Gate Valves ontents Page Figure Number Index
More informationRPPN6 - RPPN8 Industrial pressure switch with high overpressure resistance
Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Overpressure up to 100 bar Applications Energy safety equipment Power generation safety equipment
More informationAir Actuated Stainless Ball Valves 2-Piece Stainless Steel, Full Port 1/4 to 2 NPT
ir ctuated Stainless all Valves 2-Piece Stainless Steel, ull Port 1/4 to 2 SRIS eatures Spring Return or ouble cting ctuators ull Port direct mount ISO5211 valve 316 stainless steel body, ball and stem
More informationGas-actuated temperature switch Stainless steel switch enclosure Model TWG
Mechatronic Electrical temperature measurement Gas-actuated temperature switch Stainless steel switch enclosure Model TWG WIKA data sheet TV 31.60 Process Performance Series Applications Temperature monitoring
More informationTemperature Switch Gauges
Temperature Switch Gauges I MODEL DESCRIPTION MOUNTING TSG60B Bracket Mount (Standard) Surface TSG60K Back Flange Surface TSG60S Front Flange Panel TSG60X Explosion Proof (3 Switch Max.) Surface WINDOW
More informationYour Global Source for Today s Most Popular Solenoid Valves
lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves, a division of International
More informationTel-Tru Manufacturing Company World-Class Thermometers
Tel-Tru Manufacturing Company World-Class Thermometers We manufacture thermometers - but we sell service, reliability, product quality and performance. QUALITY AND PERFORMANCE FEATURES: CASE AND BEZEL
More informationHigh Performance Butterfly Valves 2 Way Way 2-20 Bray MK Series High Performance Butterfly Valves ANSI Class 150 and 300
ray MK Series High Performance utterfly Valves NSI lass 10 and 00 High Performance utterfly Valves 2 Way 2 20 Way 2 20 /2/1 The ray Mcannalok MK Series high performance butterfly valves set the quality
More informationSECTION METERS AND GAGES FOR PLUMBING PIPING
PART 1 GENERAL 1.01 SECTION INCLUDES A. Positive displacement meters. B. Flow meters. SECTION 22 0519 METERS AND GAGES FOR C. Pressure gages and pressure gage taps. D. Thermometers and thermometer wells.
More informationCLEARSCAN I2 12 INCH CHART RECORDER INSTALLATION & OPERATION MANUAL
CLEARSCAN I2 12 INCH CHART RECORDER INSTALLATION & OPERATION MANUAL Rototherm Group Kenfig Industrial Estate Margam Port Talbot SA13 2PW Tel: + 44 (0) 1656 740551 Fax: +44 (0) 1656 745915 Email: sales@rototherm.co.uk
More informationDIFFERENTIAL PRESSURE GAUGE DIAPHRAGM OPERATED
DIRNTIL PRSSUR U DIPRM OPRTD OST - R SPCIL TURS M PPROVD NCLOSUR I OPRTIN PRSSUR UP TO 100 bar SIMPL ND COMPCT DSIN COST CTIV RLIL PPLICTIONS ILTRS, YDRULIC SYSTMS, WTR TRTMNT PLNTS, CMICL PLNTS, NTURL
More informationPressure Gauge. Bourdon Tube Pressure Gauges with Switch Contacts Models MBSA, Stainless Steel Version. Applications. Special Features.
Bourdon Tube Pressure Gauges with Switch Contacts Models MBSA, Stainless Steel Version Pressure Gauge Applications Control and regulation of industrial processes Monitoring of plant and switching of electric
More informationISO Standard Hydraulic Cylinder
IO tandard ydraulic ylinder eries / eries eries Nominal pressure: a ore size :,,,, Q N Related quipment - Nominal pressure: a ore size : 3,,,,, ourtesy of teven ngineering, Inc.- Ryan Way, outh an rancisco,
More informationAir Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 NPT
ir ctuated all Valves 3-Piece Stainless Steel, ull Port 1/4 to 3 SERIES eatures Spring Return or ouble cting ctuators ull Port direct mount ISO5211 valve Swing-out bolted body design for easy maintenance
More informationTWM 7284 & TWM Microswitches equipped Thermostats type :
Microswitches equipped Thermostats type : TWM 7284 & TWM 7287 Introduction Description and general specifications Options Operating instructions and maintenance Finished product quality control tests 02
More informationCALEFFI. Motorised ball valve for central heating systems. 638 series 01196/18 GB. replaces dp 01196/12 GB
Motorised ball valve for central heating systems 638 series M 21654 003 LI 01196/18 G replaces dp 01196/12 G unction Motorised ball valves allows both automatic shut-off and diversion of the thermal medium
More informationOpen, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts
0.- Motor Starters & ontactors Low Voltage Lighting ontactors lectrically eld N January 00 Sheet 18 0 1 7 8 0 1 7 8 0 N-Open (L0-nclosed) 0 mpere 0 mpere Product escription Lighting ontactors are designed
More informationTel-Tru Manufacturing Company World-Class Thermometers
Tel-Tru Manufacturing Company World-Class Thermometers We manufacture thermometers - but we sell service, reliability, product quality and performance. QUALITY AND PERFORMANCE FEATURES: CASE AND BEZEL
More informationW94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection
Temperature Model W91 (No Indicating Dial) W94 (Temperature Indicating Dial) Service Water, Steam, Other Liquids Sizes 1/2 4 onnections Threaded, Union Ends, 125# FLG 250# FLG (optional) ody Material 1/2
More informationElectronic Temperature Control & Bulb Well Assembly (AC)
Electronic Temperature ontrol & ulb Well ssembly () 0916 86816 This is a line voltage single-stage electronic temperature control with singlepole, double-throw relay output and LED indication. It is designed
More informationDURATEMP THERMOMETERS REMOTE READING THERMOMETERS
215 DURATEMP THERMOMETER REMOTE READING THERMOMETER Product election Information... 217 Duratemp Thermometer, Remote Mount, 600A-01 eries... 218 Duratemp Thermometer, Remote Mount, 600A-02 eries... 219
More informationSelf-Operating Temperature Regulators
Self-Operating Temperature Regulators Remote Bulb for Heating, Cooling, Mixing and By-Pass Applications Powers # Regulators With Powers # Self-Operating Temperature Regulators, you no longer need external
More informationBimetal thermometer Model 52, industrial series
Mechanical temperature measurement Bimetal thermometer Model 52, industrial series WIKA data sheet TM 52.01 for further approvals see page 6 Applications A wide range of applications in machine building,
More informationCipriani Harrison Valves Corp.
pplication Sanitary ball valves are used in stainless steel piping systems for isolation, either manually or automatically operated. The full port design with zero flow restriction makes it an optimum
More informationMODEL PC-252 Transformer Temperature Indicator Oil & Winding Temperature Indicator (with Micro Switches)
1. Description: PC 252 is a Liquid-in-Metal expansion type Self powered Oil/ Winding Temperature Indicator for Power & Distribution transformers. PC 252 is Approved & Used by all reputed customers in India
More informationOIL LEVEL GAUGES FOR DISTRIBUTION TRANSFORMERS
(Model Year 2014) OIL LEVEL GAUGES FOR DISTRIBUTION TRANSFORMERS MAGNETIC OIL LEVEL GAUGES (without contacts) Page 5.26. Type IML 80 and IML 99. They are the two cheapest gauges of our range, with aluminium
More informationGas Actuated Thermometers
Gas Actuated Thermometers 401 Gas Actuated Thermometers Operating & Installation Gas actuated thermometers fall within Class IV, gas-filled with absorbent definition. They use a thermal system filled with
More informationVanessa Series 30,000 Triple Offset Valves* Cryogenic Configuration
* ryogenic onfiguration virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations Features General applications
More informationTemperature Indicating Controller
\ KF Series Temperature Indicating Controller Model KFT OVERVIEW The KF Series instruments are field-installed type of pneumatic indicating controllers which are used to measure and control the various
More informationNorth. Asia. America. Africa. South. America. Australia. Double Block and Bleed Dual Expanding Plug Valve
North merica Netherlands Europe sia frica South merica ustralia ouble lock and leed ual Expanding Plug Valve CERTIFICTES E X E CUT IO NS V Standard Execution 35 33 7 13 11 6 21 56 12 30 2 7 32 17 23 5
More information