Level Measurement Point level measurement - Rotation paddle switches

Size: px
Start display at page:

Download "Level Measurement Point level measurement - Rotation paddle switches"

Transcription

1 Siemens 017 SITRNS LPS00 Overview SITRNS LPS00 is a rotary paddle switch for point level and material detection in bulk solids. enefits Proven paddle switch technology for bulk solids High integrity mechanical seal Universal power supply options available Unique friction clutch mechanism prevents damage from falling material Rotatable enclosure for convenient wiring Optional paddles for use with low density materials Small paddle makes for simple installation through existing process connection High temperature model and optional extension kit available Optional fail-safe configuration detects loss of rotation unctional Safety (SIL ). evice suitable for use in accordance with I and I pplication The paddle switch technology detects full, empty, or demand conditions on materials such as grain, feed, cement, plastic granulate, and wood chips. The paddle switch can handle bulk densities as low as g/l (0.9 lb/ft 3 ) with the optional rectangular vane or 100 g/l (6.5 lb/ft 3 ) with the standard measuring vane. low revolution geared motor with slip clutch drives a rotating measuring vane which senses the presence of material at the mounted level of the LPS00. s material comes into contact with the rotating paddle, rotation stops, which changes the microswitch state. When the paddle is no longer covered by material, rotation resumes and the relay reverts to its normal condition. The LPS00 has a rugged design for use in harsh conditions in the solids industry. The sensitivity of the paddle can be adjusted for varying material properties like buildup on the vane. The LPS00 comes in a variety of configurations including compact, extended and cable extension. It is equipped with a standard vane which is effective in most applications, but can be configured with a hinged or rectangular vane for increased sensitivity for light materials. Key pplications: bulk solids such as grain, feed, cement, plastic granulate, wood chips Technical specifications Mode of operation Measuring principle Input Measured variable Output Output signal larm output Pickup delay Sensitivity Rotating point level switch High and low and demand Microswitch 5 at 50 V, non-inductive Microswitch SPT contact at 30 V, non-inductive Standard (1 rpm model): approx. 1.3 seconds Optional process applications (5 rpm model): approx. 0.6 seconds djustable via reset force of spring or geometry of measuring vane Rated operating conditions Installation conditions Location Indoor/outdoor mbient conditions mbient temperature ( ) Installation category III Pollution degree Medium conditions ulk solids Temperature - Standard ( ) - Optional ( ) Higher temperature version is available. onsult a local sales person for details. or more information, please visit aspa_app. Pressure (vessel) - Standard Max. 0.5 bar g (7.5 psi g) - Optional Max. 10 bar g (15 psi g) Minimum material density - Standard measuring vane an detect down to 100 g/l (6.5 lb/ft 3 ) - Optional measuring vane an detect down to 15 g/l (0.9 lb/ft 3 ) esign Material nclosure poxy coated aluminum Process connection, measuring Stainless steel or aluminum shaft and vane Process connection Thread NPT, SP, and flange options egree of protection IP65/Type /NM onduit entry x M0 x 1.5 or x ½" NPT Power supply Jumper selectable 115 V, ± 15 %, Hz, V or 30 V, ± 15 %, 50 Hz, 6 V, or 8 V, or V, or V, ± 15 %,.5 W Universal voltage (PT replay) V ± 15 % Hz, V, ± 10 %, max. 10 V ertificates and approvals S/M eneral Purpose S/M ust Ignition Proof TX II 1/ RM Iex Siemens I 01 Update 11/017 /101

2 Siemens 017 SITRNS LPS00 rticle No. Ord. code SITRNS LPS00, compact 7ML575- Rotary paddle switch for level and material detection in bulk solids. ompact design for side or top mounted applications. lick on the rticle No. for the online configuration in the PI Life ycle Portal. Process temperature Up to 80 (176 ) 1 Up to 150 (30 ) Up to 50 (8 ) 3 Up to 600 (1 11 ) 1)) Up to 80 (176 ) basic version aluminum 1)3) 5 Up to 80 (176 ) basic version stainless steel 1)) 6 Power supply 30 V, 1 rev/min. 30 V, 5 rev/min. 115 V, 1 rev/min. 115 V, 5 rev/min. 8 V, 1 rev/min. J V, 1 rev/min. K V, 1 rev/min. L V, 5 rev/min. N 8 V, 5 rev/min. Z J 1 V, 5 rev/min. Z J 1 Universal Voltage, 1 rev/min. Z J Universal Voltage, 1 rev/min., fail-safe Z J Universal Voltage, 5 rev/min. Z J Universal Voltage, 5 rev/min, fail-safe Z J Process connection Threaded 1¼" [(SPP), N ISO 8-1] 1" [(SPP), N ISO 8-1] 1½" [(SPP), N ISO 8-1] 1" NPT [(Taper), NSI/SM 1.0.1] 1¼" NPT [(Taper), NSI/SM 1.0.1] 1½" NPT [(Taper), NSI/SM 1.0.1] langed N 3 PN 6, N ) N 100 PN 6, N ) H N 100 PN 16, N J " SM 150 lb 16.5 K 3" SM 150 lb 16.5 L " SM 150 lb 16.5 M " Tri-clamp (N 50) ISO 85 6) N rticle No. Ord. code SITRNS LPS00, compact 7ML575- Rotary paddle switch for level and material detection in bulk solids. ompact design for side or top mounted applications Process pressure Up to 0.5 bar (7.5 psi) 1 Up to 5 bar (7.5 psi) Up to 10 bar (15 psi) 3 Process connection material luminum 7) 1 Stainless steel, threads 303 (1.305), flanges 31 (1.51), Tri-clamp 30 (1.301) Stainless steel 316L (1.0) 8) 3 xtension length 100 mm (3.9 inch) 9) mm (5.91 inch) 00 mm (7.87 inch) 3 50 mm (9.8 inch) 300 mm (11.81 inch) 5 Measuring vane oot shaped, 35 x 106 mm (1.38 x.17 inch) 10) Hinged vane, 65 x 00 mm (.56 x 7.87 inch) 10)11) oot shaped, 8 x 98 mm (1.10 x 3.86 inch) Rectangular, 50 x 150 mm (1.97 x 5.91 inch) 1) Rectangular, 50 x 50 mm (1.97 x 9.8 inch) 1) Rectangular, 98 x 150 mm (3.86 x 5.91 inch) 11)1) Rectangular, 98 x 50 mm (3.86 x 9.8 inch) 11)1) Rectangular, 50 x 98 mm (1.97 x 3.86 inch) 1) H pprovals S/M ust Ignition Proof, RM TX II 1/, RM S/M eneral Purpose, RM,, RM I x ta/tb III x ta/tb III a/b /10 Siemens I 01 Update 11/017

3 Siemens 017 SITRNS LPS00 1 Order code هى مء مو ء Please add "-Z" to rticle No. and specify Order code(s). Heating of enclosure 13)1) 35 Signal bulb inserted in M0 cable gland 13) 0 ood grade materials (in contact with process), K01 according to 1935/00/, with conform shaft sealing 15) Stainless steel tag [100 x 5 mm (3.9 x 1.77 inch)]: Y1 Measuring-point number/identification (max. 7 characters); specify in plain text unctional Safety (SIL ). evice suitable for use in 0 accordance with I and I )18) ى ك ة ه ى ف م د rticle No. Multi-language Note: The Operating Instructions should be ordered as a separate line on the order. ll literature is available to download for free, in a range of languages, at processinstrumentation/documentation فذ م ف س Replacement vane, boot shape, 35 x 106 mm 7ML1830-1KH (1.38 x.17 inch) Hinged vane, 65 x 00 mm (.56 x 7.87 inch) 7ML1830-1KJ ى ى م م لىهىز (Includes spring coupling, rigid tube extension, and required pins) xtension: 500, 00, 300 mm (19.7, 15.8, 7ML inch) 16) xtension: 1 000, 900, 800, 700, 600 mm 7ML (39., 35., 31.5, 7.6, 3.6 inch) 16) xtension: 1 500, 1 00, 1 300, 1 00, mm 7ML5711- (59.1, 55.1, 51., 7., 3.3 inch) 16) Rope extension kit, m (6.56 ft) 7ML1830-1KK ك م م قف ىف ء or details see page 10/11 in the appendix. SITRNS LPS00, compact for up to 80 (176 ), aluminum, with power supply, process connection, process pressure 1, process connection material 1, extension length, measuring vane, and approval SITRNS LPS00, compact for up to 80 (176 ), stainless steel, with power supply Z (J), process connection, process pressure 1, process connection material, extension length, measuring vane, and approval SITRNS LPS00, compact for up to 80 (176 ), stainless steel, with power supply Z (J), process connection, process pressure 1, process connection material, extension length, measuring vane, and approval 1) vailable with approval options and only, up to 0.5 bar. ) Not available with process connections,,,, and. rticle No. 7ML ML575-6Z1-0 J 7ML575-6Z1-0 J 3) Only available with the following configurations 7ML or 7ML ) Only available with the following configurations 7ML575-6Z1-0 J or 7ML575-6Z1-0 J. 5) vailable with process pressure options 1 and only. 6) vailable with process temperature option 1 only. 7) vailable with process connection options... only, process pressure option 1 and process temperature options 1 and 5 only. 8) vailable with process connection options,, H N and Measuring vane options and. 9) vailable with measuring vane options,,,, H only. 10) dd 16 mm (0.63 inch) to extension length. 11) vailable with extension lengths, 3,, 5. 1) vailable with process connection options H M only. 13) vailable with approval option only. 1) vailable with power supply options,,,, J, K, L, N, J1, J1, J1, J, J only. 15) vailable up to 50 (8 ). This option does not automatically implement a food conform design. 16) Pendulum shaft 500 mm/1 000 mm/1 500 mm should be selected with 150 mm standard length and vane (35 x 106) to get to the desired lengths. 17) vailable with Power supply options J and J only. 18) vailable with pproval options,,,, and only. pprovals and with M only. Siemens I 01 Update 11/017 /103

4 Siemens 017 SITRNS LPS00 rticle No. Ord. code SITRNS LPS00, shaft protected 7ML576- Rotary paddle switch for level and material detection in bulk solids; ideal for heavy, sticky, or high impact applications. esigned with added protection tube for enhanced shaft protection and protection against buildup on shaft (sidewall buildup). lick on the rticle No. for the online configuration in the PI Life ycle Portal. Process temperature Up to 80 (176 ) 1 Up to 150 (30 ) Up to 50 (8 ) 3 Up to 600 (1 11 ) 1)) Up to 80 (176 ) basic version 3) 5 Power supply 30 V, 1 rev/min. 30 V, 5 rev/min. 115 V, 1 rev/min. 115 V, 5 rev/min. 8 V, 1 rev/min. J V, 1 rev/min. K V, 1 rev/min. L V, 5 rev/min. N 8 V, 5 rev/min. Z J 1 V, 5 rev/min. Z J 1 Universal Voltage, 1 rev/min. Z J Universal Voltage, 1 rev/min., fail-safe Z J Universal Voltage, 5 rev/min. Z J Universal Voltage, 5 rev/min., fail-safe Z J Process connection Threaded 1¼" [(SPP), N ISO 8-1] 1½" [(SPP), N ISO 8-1] 1¼" NPT [(Taper), NSI/SM 1.0.1] 1½" NPT [(Taper), NSI/SM 1.0.1] langed N 3 PN 6, N ) N 100 PN 6, N ) N 100 PN 16, N " SM 150 lb 16.5 H 3" SM 150 lb 16.5 J " SM 150 lb 16.5 K " Tri-clamp (N 50) ISO 85 5) L rticle No. Ord. code SITRNS LPS00, shaft protected 7ML576- Rotary paddle switch for level and material detection in bulk solids; ideal for heavy, sticky, or high impact applications. esigned with added protection tube for enhanced shaft protection and protection against buildup on shaft (sidewall buildup). Process pressure Up to 0.5 bar (7.5 psi) 1 Up to 5 bar (7.5 psi) Up to 10 bar (15 psi) 3 Process connection material luminum 6) 1 Stainless steel, threads 303 (1.305), flanges 31 (1.51), Tri-clamp 30 (1.301) 18) Stainless steel 316L (1.0) 7) 3 xtension length 150 mm (5.91 inch) 8) 1 00 mm (7.87 inch) 50 mm (9.8 inch) mm (11.81 inch) xtension material (protection tube) luminum 9) Stainless steel 303 (1.305) Stainless steel 316L (1.0) 10) Measuring vane oot shaped, 35 x 106 mm (1.38x.17inch) 11) Hinged vane, 65 x 00 mm (.56 x 7.87 inch) 11)1) Rectangular, 50 x 150 mm (1.97x5.91inch) 13) Rectangular, 50 x 50 mm (1.97x9.8inch) 13) Rectangular, 98 x 150 mm (3.86x5.91inch) 1)13) Rectangular, 98 x 50 mm (3.86x9.8inch) 1)13) Rectangular, 50 x 98 mm H (1.97 x 3.86 inch) 13) pprovals S/M ust Ignition Proof, RM 1 TX II 1/, RM S/M eneral Purpose, RM, 3, RM I x ta/tb III 5 x ta/tb III a/b 6 /10 Siemens I 01 Update 11/017

5 Siemens 017 SITRNS LPS00 هى مء مو ء Please add "-Z" to rticle No. and specify Order code(s). Heating of enclosure 1)15) Signal bulb inserted in M0 cable gland 1) ood grade materials (in contact with process), according to 1935/00/, with conform shaft sealing 16) Stainless steel tag [100 x 5 mm (3.9 x 1.77 inch)]: Measuring-point number/identification (max. 7 characters); specify in plain text unctional Safety (SIL ). evice suitable for use in accordance with I and I )19) ى ك ة ه ى ف م د Multi-language Note: The Operating Instructions should be ordered as a separate line on the order. ll literature is available to download for free, in a range of languages, at processinstrumentation/documentation فذ م ف س Replacement vane, boot shape, 35 x 106 mm (1.38 x.17 inch) Hinged vane, 65 x 00 mm (.56 x 7.87 inch) ك م م قف ىف ء or details see page 10/11 in the appendix. SITRNS LPS00, extended for up to 80 (176 ), power supply Z (J), process connection, process pressure 1, process connection material, extension length, extension material, measuring vane, and approval SITRNS LPS00, extended for up to 80 (176 ), power supply Z (J), process connection, process pressure 1, process connection material, extension length, extension material, measuring vane, and approval 1 Order code 35 0 K01 Y1 0 1) vailable with approval options 3 and only and up to max 0.5 bar. ) Not available with process connection options,,. 3) Only available with the following configurations 7ML576-5Z1- J or 7ML576-5Z1-1 J. ) vailable with process pressure options 1 and only. 5) vailable with process temperature option 1 only. 6) vailable with process connection options... only, available with process pressure option 1 only, and process temperature option 1 only. 7) xtension and vane will also change to 316L, only for process connection options,, L and vane. 8) vailable with measuring vane options,,, H only. 9) vailable with process pressure option 1 and process temperature option 1 only. 10) vailable with process connection options,, L and vane. 11) dd 16 mm (0.63 inch) to extension length. 1) vailable with extension length options only. 13) vailable with process connection options,, H, J, K only. 1) vailable with approval option only. 15) vailable with power supply options,,,, J, K, L, N, J1, J1, J1, J, J only. 16) vailable up to 50 (8 ). This option does not automatically implement a food conform design. 17) vailable with Power supply options J and J only. 18) vailable with xtension material Stainless steel, threads 303 option only. 19) vailable with pproval options 1,, 3,, and 5 only. pprovals 1 and 3 with M only. rticle No ML1830-1KH 7ML1830-1KJ 7ML576-5Z1- J 7ML576-5Z1-1 J Siemens I 01 Update 11/017 /105

6 Siemens 017 SITRNS LPS00 rticle No. Ord. code SITRNS LPS00, cable extension 7ML577- Rotary paddle switch for level and material detection in bulk solids able extension for increased length in top-mounted applications lick on the rticle No. for the online configuration in the PI Life ycle Portal. Process temperature Up to 80 (176 ) 1 Up to 150 (30 ) Up to 50 (8 ) 3 Up to 600 (1 11 ) 1)) Up to 80 (176 ) basic version 3) 5 Power supply 30 V, 1 rev/min. 30 V, 5 rev/min. 115 V, 1 rev/min. 115 V, 5 rev/min. 8 V, 1 rev/min. J V, 1 rev/min. K V, 1 rev/min. L V, 5 rev/min. N 8 V, 5 rev/min. Z J 1 V, 5 rev/min. Z J 1 Universal Voltage, 1 rev/min. Z J Universal Voltage, 1 rev/min., fail-safe Z J Universal Voltage, 5 rev/min. Z J Universal Voltage, 5 rev/min., fail-safe Z J Process connection Threaded 1¼" [(SPP), N ISO 8-1] 1½" [(SPP), N ISO 8-1] 1¼" NPT [(Taper), NSI/SM 1.0.1] 1½" NPT [(Taper), NSI/SM 1.0.1] langed N 3 PN 6, N ) N 100 PN 6, N ) N 100 PN 16, N " SM 150 lb 16.5 H 3" SM 150 lb 16.5 J " SM 150 lb 16.5 K rticle No. Ord. code SITRNS LPS00, cable extension 7ML577- Rotary paddle switch for level and material detection in bulk solids able extension for increased length in top-mounted applications Process pressure Up to 0.5 bar (7.5 psi) 1 Up to 5 bar (7.5 psi) Up to 10 bar (15 psi) 3 Process connection material luminum 5) 1 Stainless steel, threads 303 (1.305), flanges 31 (1.51) able extension length Standard cable length, 000 mm 0 (78.7 inch) dd Order code Y01 and plain text: "Insertion length... mm" mm ( inch) 1 able length mm ( inch) able length mm 3 ( inch) able length mm ( inch) able length mm 5 ( inch) able length mm 6 ( inch) able length mm 7 ( inch) able length mm 8 ( inch) Without extension 1) 9 N 1 Measuring vane oot shaped, 35 x 106 mm (1.38x.17inch) 6) Hinged vane, 65 x 00 mm (.56 x 7.87 inch) 6) oot shaped, 8 x 98 mm (1.10 x 3.86 inch) 7) Rectangular, 50 x 150 mm (1.97 x 5.91 inch) 7) Rectangular, 50 x 50 mm (1.97 x 9.8 inch) 7) Rectangular, 98 x 150 mm (3.86 x 5.91 inch) 7) Rectangular, 50 x 98 mm (1.97 x 3.86 inch) 7) pprovals S/M ust Ignition Proof, RM TX II 1/, RM S/M eneral Purpose, RM,, RM I x ta/tb III x ta/tb III a/b /106 Siemens I 01 Update 11/017

7 Siemens 017 SITRNS LPS00 هى مء مو ء Order code Please add "-Z" to rticle No. and specify Order code(s). Total insertion length: nter the total insertion length in plain text description, max mm ( inch) Stainless steel tag [100 x 5 mm (3.9 x 1.77 inch)]: Measuring-point number/identification (max. 7 characters); specify in plain text Reinforced cable (max. 8 kn pulling force) 8) Heating of enclosure 9)10) Signal bulb inserted in M0 cable gland 9) ood grade materials (in contact with process), according to 1935/00/, with conform shaft sealing 11) unctional Safety (SIL ). evice suitable for use in accordance with I and I )1) ى ك ة ه ى ف م د Multi-language Note: The Operating Instructions should be ordered as a separate line on the order. ll literature is available to download for free, in a range of languages, at processinstrumentation/documentation فذ م ف س Replacement vane, boot shape, 35 x 106 mm (1.38 x.17 inch) Hinged vane, 65 x 00 mm (.56 x 7.87 inch) ك م م قف ىف ء or details see page 10/11 in the appendix. SITRNS LPS00, cable extension for up to 80 (176 ), power supply Z (J), process connection, process pressure 1, process connection material, extension length 0, measuring vane, and approval SITRNS LPS00, cable extension for up to 80 (176 ), power supply Z (J), process connection, process pressure 1, process connection material, extension length 0, measuring vane, and approval Y01 Y1 P K01 0 rticle No ML1830-1KH 7ML1830-1KJ 7ML577-5Z1-00 J 7ML577-5Z1-00 J 1) vailable with approval options and up to max. 0.5 bar ) Not available with process connections,, 3) Only available with the following configurations 7ML577-5Z1-00 J or 7ML577-5Z1-00 J ) vailable with process pressure options 1 and only 5) vailable with process connections... only, process pressure option 1 only and process temperature options 1 and 5 only 6) dd 16 mm (0.63 inch) to extension length 7) vailable with process connections K only 8) vailable only for process temperature up to 80 (176 ) and process connection material 9) vailable with approval option 10) vailable with power supply options,,,, J, K, L, N, J1, J1, J1, J, J only 11) vailable up to 50 (8 ). This option does not automatically implement a food conform design (food conform gaps and radius) 1) Not available with P01 and available with pproval, mounting kit for rope extension included 13) vailable with Power supply options J and J only 1) vailable with pproval options,,,, and only. pprovals and with M only. Siemens I 01 Update 11/017 /107

8 Siemens 017 SITRNS LPS00 rticle No. Ord. code SITRNS LPS00, angled extension 7ML578- Rotary paddle switch with robust design for level and material detection in bulk solids; ideal for heavy or sticky applications. ngled extension is designed to avoid falling material and rotates horizontally in side mount applications to continue working even with heavy buildup. lick on the rticle No. for the online configuration in the PI Life ycle Portal. Process temperature Up to 80 (176 ) 1 Up to 150 (30 ) Up to 50 (8 ) 3 Power supply 30 V, 1 rev/min. 30 V, 5 rev/min. 115 V, 1 rev/min. 115 V, 5 rev/min. 8 V, 1 rev/min. J V, 1 rev/min. K V, 1 rev/min. L V, 5 rev/min. N 8 V, 5 rev/min. Z J 1 V, 5 rev/min. Z J 1 Universal Voltage, 1 rev/min. Z J Universal Voltage, 1 rev/min., fail-safe Z J Universal Voltage, 5 rev/min. Z J Universal Voltage, 5 rev/min., fail-safe Z J Process connection langed N 100 PN 6, N ) N 100 PN 16, N " SM 150 lb 16.5 Process pressure Up to 0.5 bar (7.5 psi) 1 Up to 5 bar (7.5 psi) Up to 10 bar (15 psi) 3 Process connection material Stainless steel 303/31 (1.305/1.51) 1 xtension length 15 mm (.9 inch) mm (5.91 inch) 00 mm (7.87 inch) 3 50 mm (9.8 inch) 300 mm (11.81 inch) 5 Measuring vane Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch) Rectangular vane, 50 x 150 mm (1.97x5.91inch) Rectangular vane, 50 x 50 mm (1.97x9.8inch) Rectangular vane, 98 x 150 mm (3.86x5.91inch) Rectangular vane, 98 x 50 mm (3.86x9.8inch) Hinged vane, 65 x 00 mm (.56 x 7.87 inch) pprovals S/M ust Ignition Proof, RM TX II 1/, RM S/M eneral Purpose, RM,, RM I x ta/tb III x ta/tb III a/b هى مء مو ء Please add "-Z" to rticle No. and specify Order code(s). Heating of enclosure )3) Signal bulb inserted in M0 cable gland ) ood grade materials (in contact with process), according to 1935/00/, with conform shaft sealing ) Stainless steel tag [100 x 5 mm (3.9 x 1.77 inch)]: Measuring-point number/identification (max. 7 characters); specify in plain text unctional Safety (SIL ). evice suitable for use in accordance with I and I )6) ى ك ة ه ى ف م د Multi-language Note: The Operating Instructions should be ordered as a separate line on the order. ll literature is available to download for free, in a range of languages, at processinstrumentation/documentation فذ م ف س Replacement vane, boot shape, 35 x 106 mm (1.38 x.17 inch) Hinged vane, 65 x 00 mm (.56 x 7.87 inch) Order code 35 0 K01 Y1 0 rticle No ML1830-1KH 7ML1830-1KJ 1) vailable with process pressure options 1 and only. ) vailable with approval option only. 3) vailable with power supply options,,,, J, K, L, N, J1, J1, J1, J, J only. ) This option does not automatically implement a food conform design. 5) vailable with Power supply options J and J only. 6) vailable with pproval options,,,, and only. pprovals and with M only. /108 Siemens I 01 Update 11/017

9 Siemens 017 SITRNS LPS00 rticle No. Ord. code SITRNS LPS00, rigid extension 7ML5730- Rotary paddle switch for top mount point level and material detection in bulk solids lick on the rticle No. for the online configuration in the PI Life ycle Portal. Process temperature Up to 80 (176 ) 1 Up to 150 (30 ) Up to 50 (8 ) 3 Up to 600 (1 11 ) 1)) Power supply 30 V, 1 rev/min. 30 V, 5 rev/min. 115 V, 1 rev/min. 115 V, 5 rev/min. 8 V, 1 rev/min. J V, 1 rev/min. K V, 1 rev/min. L V, 5 rev/min. N 8 V, 5 rev/min. Z J 1 V, 5 rev/min. Z J 1 Universal Voltage, 1 rev/min. Z J Universal Voltage, 1 rev/min., fail-safe Z J Universal Voltage, 5 rev/min. Z J Universal Voltage, 5 rev/min., fail-safe Z J Process connection Threaded 1¼" [(SPP), N ISO 8-1] 1½" [(SPP), N ISO 8-1] 1¼" NPT [(Taper), NSI/SM 1.0.1] 1½" NPT [(Taper), NSI/SM 1.0.1] langed N 3 PN 6, N ) N 100 PN 6, N ) N 100 PN 16, N " SM 150 lb 16.5 H 3" SM 150 lb 16.5 J " SM 150 lb 16.5 K " Tri-clamp (N 50) ISO 85 ) L rticle No. Ord. code SITRNS LPS00, rigid extension 7ML5730- Rotary paddle switch for top mount point level and material detection in bulk solids Process pressure Up to 0.5 bar (7.5 psi) 1 Up to 5 bar (7.5 psi) Up to 10 bar (15 psi) 3 Process connection material luminum 5) 1 Stainless steel, threads 303 (1.305), flanges 31 (1.51), Tri-clamp 30 (1.301) Stainless steel 316L (1.0) 6) 3 xtension material (protection tube) luminum 7)8) 0 Stainless steel 303 (1.305) 9) 1 Stainless steel 316L (1.0) 10)11)) xtension length luminum mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) mm ( inch) H mm ( inch) J mm ( inch) K mm ( inch) L mm ( inch) M mm ( inch) N mm ( inch) P mm ( inch) Q Stainless steel 303 (1.305) mm ( inch) R mm ( inch) S mm ( inch) T mm ( inch) U mm ( inch) V mm ( inch) W mm ( inch) X mm ( inch) Y Stainless steel 316L (1.0) mm ( inch) Z P mm ( inch) Z P mm ( inch) Z P mm ( inch) Z P mm ( inch) Z P mm ( inch) Z P mm ( inch) Z P mm ( inch) Z P 1 H Siemens I 01 Update 11/017 /109

10 Siemens 017 SITRNS LPS00 rticle No. Ord. code SITRNS LPS00, rigid extension 7ML5730- Rotary paddle switch for top mount point level and material detection in bulk solids Measuring vane oot shaped, 35 x 106 mm (1.3 x.17 inch) 1) Hinged vane, 65 x 00 mm (.56 x 7.87 inch) 1) Rectangular, 50 x 150 mm (1.97 x 5.91 inch) 13) Rectangular, 50 x 50 mm (1.97 x 9.8 inch) 13) Rectangular, 98 x 150 mm (3.86 x 5.91 inch) 13) Rectangular, 98 x 50 mm (3.86 x 9.8 inch) 13) Rectangular, 50 x 98 mm (1.97 x 3.86 inch) 13) pprovals S/M ust Ignition Proof, RM 1 TX II 1/, RM S/M eneral Purpose, RM, 3, RM I x ta/tb III 5 x ta/tb III a/b 6 1) vailable with approval options 3 and, up to max 0.5 bar ) Not available with process connections,,. 3) vailable with process pressure options 1 and only. ) vailable with process temperature 1 only. 5) vailable with process connections... only, with process pressure option 1 and process temperature option 1 only. 6) vailable with process connection options,, L and measuring vane option. 7) vailable with process pressure 1 and process temperature 1 only. 8) vailable with extension length options Q only. 9) vailable with extension length options R Y only. 10) vailable with process connection options,, L and measuring vane, process connection material 3. vailable only with extension length options P1 P1H only. 11) Only available with seal at tube end options P06 P09. 1) dd 16 mm (0.63 inch) to extension length. 13) vailable with process connections,, H, J, K only. 1) vailable with approval option only. 15) vailable with power supply options,,,, J, K, L, N, J1, J1, J1, J, J only. 16) vailable when ordered with ingress protection seal options P06 P09 only. 17) vailable up to 50 (8 ). This option does not automatically implement a food conform design. 18) vailable with process pressure option 1 only. هى مء مو ء Please add "-Z" to rticle No. and specify Order code(s). Total insertion length: nter the total insertion length in plain text description, max. 000 mm (157.8 inch) Stainless steel tag [100 x 5 mm (3.9 x 1.77 inch)]: Measuring-point number/identification (max. 7 characters); specify in plain text unctional Safety (SIL ). evice suitable for use in accordance with I and I )1) Heating of enclosure 1)15) Signal bulb inserted in M0 cable gland 1) ood grade materials (in contact with process), according to 1935/00/, with conform shaft sealing 16)17) Optional end of shaft seal for stability and ingress protection Max. temperature 80 (176 ) Max. temperature 150 (30 ) Max. temperature 50 (8 ) Max. temperature 600 (1 11 ) Sliding sleeve (standard, max. pressure 0.5 bar) 1)18) Sliding sleeve (pressure tight, for over-pressure application starting from 1 bar max., dependent on pressure option ordered) 19) ى ك ة ه ى ف م د Multi-language Note: The Operating Instructions should be ordered as a separate line on the order. ll literature is available to download for free, in a range of languages, at processinstrumentation/documentation فذ م ف س Replacement vane, boot shape, 35 x 106 mm (1.38 x.17 inch) Hinged vane, 65 x 00 mm (.56 x 7.87 inch) Order code Y01 Y K01 P06 P07 P08 P09 P1 P ML1830-1KH 7ML1830-1KJ 19) vailable up to 50 (8 ). 0) vailable with Power supply options J and J only. 1) vailable with pproval options 1,, 3,, and 5 only. pprovals 1 and 3 with M only. ) Internal probe construction is 1.305, add seal option P09 to prevent ingress. /110 Siemens I 01 Update 11/017

11 Siemens 017 SITRNS LPS00 imensional drawings Standard model: compact version onduit connection M0 or ½" NPT mbient temperature ( ) Zone 1 (at. ) Zone 0 (at. 1) Process temperature ( ) Measuring vanes 35 (1.38) Thread length SP: 0.5 (0.81) NPT: (0.9) Standard 106 (.17) Rectangular 60 (.36) Hinged old together to lead into mounting hole 10 (.7) Measuring vane Rectangular vane options 50 (1.97) 50 (1.97) 50 (1.97) 98 (3.86) 98 (3.86) 60 (.36) 75 (.95) 13 (.8) Optional process flange 1. or 35 x 106 mm boot shaped and 98 x 00 mm hinged measuring vanes, add 16 mm to extension length.. or use with all approval options except S class II. See manual for more details. Notes or heavy material, only top mounting of paddle switch is recommended. ompact LPS00 is recommended for side mounting on bins for low or intermediate material levels. 1) L 98 (3.86) 150 (5.90) 50 (9.8) 150 (5.90) 50 (9.8) Min. 37 (1.6) High temperature model: compact version Shaft protected option Vane oot shaped 35 x 106 mm oot shaped 8 x 98 mm Rectangular 50 x 98 mm Rectangular 50 x 150 mm Rectangular 50 x 50 mm Rectangular 98 x 150 mm Rectangular 98 x 50 mm Hinged 98 x 00 mm Thread length SP: 0.5 (0.81) NPT: (0.9) mbient temperature ( ) Zone 1 (at. ) Zone 0 (at. 1) Process temperature ) ( ) 1) L 00 (7.87) ngle option 98 (3.86) ( ) ompletely covered with material 80 g/l (5.0 lb/ft³) 30 g/l (1.9 lb/ft³) 30 g/l (1.9 lb/ft³) 0 g/l (1. lb/ft³) 70 g/l (. lb/ft³) (7.5 lb/ft³) 50 g/l (3.1 lb/ft³) 50 g/l (3.1 lb/ft³) 30 g/l (1.9 lb/ft³) Rope fixing Spring adjustment Light entral (factory setting) 00 g/l 300 g/l (1.5 lb/ft³) (18.7 lb/ft³) 300 g/l (18.7 lb/ft³) 300 g/l (18.7 lb/ft³) 500 g/l (31. lb/ft³) 500 g/l (31. lb/ft³) 10 g/l 100 g/l (6. lb/ft³) 1) L Process temperature L= Length Rope option 000 (78.7) standard; an be shortened by the customer; total length available (393.7) overed up to 10 cm (3.93 inch) with material Spring adjustment Light entral (factory setting) 100 g/l 150 g/l (6. lb/ft³) (9. lb/ft³) 150 g/l 150 g/l (9. lb/ft³) (9. lb/ft³) 150 g/l 50 g/l (9. lb/ft³) (15.6 lb/ft³) 0 g/l 60 g/l (.5 lb/ft³) (3.7 lb/ft³) 15 g/l (0.9 lb/ft³) 15 g/l (0.9 lb/ft³) 15 g/l (0.9 lb/ft³) 35 g/l (. lb/ft³) 150/50 (30/8 º) 600 (1 11 º) 100 (3.9) 150 (5.91) 00 (7.87) 50 (9.8) 300 (11.81) 00 (7.87) 00 (15.7) 5 g/l (1.6 lb/ft³) 5 g/l (1.6 lb/ft³) 15 g/l (0.9 lb/ft³) 50 g/l (3.1 lb/ft³) SITRNS LPS00, dimensions in mm (inch) Siemens I 01 Update 11/017 /111

12 S 3 S Siemens 017 SITRNS LPS00 Schematics or version Max. mm (W1) Universal voltage (PT relay)* Max. mm (W1) * See manual for universal voltage with SIL. ** With option ail safe alarm (rotation control). ontact open when de-energised. ail safe alarm switching and timing behaviour: If the vane is not covered, the rotating vane shaft will send pulses at 0 second intervals. In case of fault, the pulses are missed. fter 30 seconds, the alarm relay will open. L N P Signal output + - Power Supply Power supply: Signal output PT Signal output: delay larm output ** L N P + - Power Supply version: V or 8 V or 115 V or 30 V 50/60 Hz max. V ll voltages ± 10 % 1) Supply voltage as selected. xternal fuse: max 10, fast or slow, H, 50 V version: V ± 15 % 1) max..5 W xternal fuse: not required 1) Including ±10% of N Signal output: Micro switch, SPT contact max. 50 V, 5, non inductive max. 30 V,, non inductive xternal fuse: max 10, fast or slow, H, 50 V Sensor covered -> free actory setting = 3 sec S S Sensor covered -> covered actory setting = 1 sec SITRNS LPS00 connections /11 Siemens I 01 Update 11/017

Level Measurement Point level measurement - Vibrating switches

Level Measurement Point level measurement - Vibrating switches Siemens G 2018 SITRNS LVS200 Overview SITRNS LVS200 is a vibrating point level switch for high, low, or demand level detection of bulk solids. enefits High resistance to mechanical forces Strong vibration

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview. Level Measurement Pointek LS200 Standard Siemens A 20 Overview onfiguration Installation Pointek LS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable

More information

Solids Flowmeters LVDT flowmeters

Solids Flowmeters LVDT flowmeters Siemens 2017 STRNS W200 series Overview pplication Operating with a microprocessor based integrator package, the W200 series flowmeters display flow rate, totalized flow, and rate alarms. Outputs are 0/4

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters Overview Configuration Installation Note: Beam angle is the width of the cone where the energy density is half of the peak energy density Emission The peak energy density cone is directly in front of and

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Siemens G 2014 SITRNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals, acids, alkalis

More information

Level Measurement Point level measurement - Vibrating switches

Level Measurement Point level measurement - Vibrating switches Overview Configuration Horizontal mounting (recommended mounting position, particularly for adhesive applications) Vertical mounting is a compact vibrating level switch for material detection in liquid

More information

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview. Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS300 - Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level and material detection switch with optional rod/cable choices

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Soliswitch FTE20. Technical Information. Point level switch for granular solids

Soliswitch FTE20. Technical Information. Point level switch for granular solids Technical Information Point level switch for granular solids Applications The is a paddle switch for granular solids. Its robust and compact design makes the point level switch an ideal sensor for detecting

More information

Soliswitch FTE30. Technical Information

Soliswitch FTE30. Technical Information Technical Information Soliswitch FTE30 Level limit switch Economical paddle limit switch with type-examination certificate to ATEX dust Ex-approval zone 20 Application The universal paddle level limit

More information

ROTARY Point Level Measurement for Inventory Control

ROTARY Point Level Measurement for Inventory Control Measure. Detect. Alert. ROTARY Point Level Measurement for Inventory Control Detect high and low levels while protecting valuable inventory with tried-and-true rotary level indicators from BinMaster. Made

More information

Level limit switch Series RN 3000 / 6000 Selection list

Level limit switch Series RN 3000 / 6000 Selection list Table of contents Overview 2 Specifications 4 Applications 6 Page -------------------------------------------------------------------------------------------------------- RN..001 8 Short extension length

More information

Process Protection Motion sensors

Process Protection Motion sensors Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Design Benefits Up to 100 mm (4 inch) gap between target and

More information

Process Protection Motion sensors

Process Protection Motion sensors Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Application The MFA 4p detects changes in the motion and speed

More information

Level Measurement Continuous level measurement Ultrasonic transmitters

Level Measurement Continuous level measurement Ultrasonic transmitters Siemens AG 2018 Overview Configuration ultrasonic level transmitter, ideal for level, volume, and volume flow measurements. It works with liquids, slurries, and bulk materials up to 12 m (0 ft). Benefits

More information

Level limit switch Series RF 3000 Selection list

Level limit switch Series RF 3000 Selection list Table of content Page Overview P2 Applications P4 ------------------------------------------------------------------------------------------------------------- RF 3100 Standard version P6 -------------------------------------------------------------------------------------------------------------

More information

SITRANS L Level instruments

SITRANS L Level instruments Overview Configuration is a compact vibrating level switch for use in liquid applications such as overflow, high, low and demand applications, as well as pump protection. It is ideal for use in confined

More information

Point level measurement Capacitance switches

Point level measurement Capacitance switches Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.

More information

Level instruments. Point level measurement - Vibrating switches SITRANS LVL100. 5/78 Siemens FI Horizontal mounting.

Level instruments. Point level measurement - Vibrating switches SITRANS LVL100. 5/78 Siemens FI Horizontal mounting. evel instruments Siemens AG 2009 Overview Configuration Horizontal mounting (recommended mounting position, particularly for adhesive applications) Vertical mounting with lower density is a compact vibrating

More information

Level limit switch Series RN 3000 / 6000 Selection list. Overview. Specifications. Applications

Level limit switch Series RN 3000 / 6000 Selection list. Overview. Specifications. Applications Table of contents Page Overview Specifications Applications P2 P4 P6 --------------------------------------------------------------------------------------------------------- RN..001 Short extension length

More information

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview Siemens G 2009 SITRNS flowmeters SITRNS C SITRNS C MC2 Overview SITRNS C MC2 is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG-certified version (DN 20 to DN (¾ to 3

More information

Level limit switch Series RN 3000 / 6000 Selection list

Level limit switch Series RN 3000 / 6000 Selection list Table of contents Page Overview Specifications Applications P2 P4 P6 -------------------------------------------------------------------------------------------------------- RN..001 Short extension length

More information

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4 Table of contents Page Specifications 2 Applications 4 ------------------------------------------------------------------------------------------------------------ CN 4020 5 Short extension length ------------------------------------------------------------------------------------------------------------

More information

SITRANS F C. Flow sensor MC2 4/193. Overview

SITRANS F C. Flow sensor MC2 4/193. Overview Siemens G 2011 low Measurement SITNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals,

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Overview Configuration Installation is an inverse frequency shift capacitance level and material detection switch ideal for detecting interfaces, solids, liquids, toxic, and aggressive chemicals in critical

More information

Level limit switch Series RN 3000 / 6000 Selection list. Overview

Level limit switch Series RN 3000 / 6000 Selection list. Overview Rotonivo Table of contents Page Overview Specifications Applications P2 P4 P6 -------------------------------------------------------------------------------------------------------- RN..00 Short extension

More information

STOCKTROL-H VIBRATING LEVEL SWITCH. Instruction Manual June 2002

STOCKTROL-H VIBRATING LEVEL SWITCH. Instruction Manual June 2002 STOCKTROL-H VIBRATING LEVEL SWITCH Instruction Manual June 2002 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the

More information

Pressure Measurement Fittings

Pressure Measurement Fittings Siemens G 2018 Overview ll shut-off fittings can be secured onto walls, racks (72 mm grid) and vertical and horizontal pipes. This offers the advantage when assembling a plant that the shutoff fittings

More information

Level limit switch Series RN 4000 Selection list. Overview / Specification / Applications

Level limit switch Series RN 4000 Selection list. Overview / Specification / Applications Table of contents Page Overview / Specification / Applications P2 ----------------------------------------------------------------------------------------------------------- Selection P3 -----------------------------------------------------------------------------------------------------------

More information

Operating instructions According to Directive 2014/34/EU (ATEX) Annex II p group II, equipment category 1/2D

Operating instructions According to Directive 2014/34/EU (ATEX) Annex II p group II, equipment category 1/2D 1. Introduction Fig.1 MAX. ( Process ) MIN. ( Ambient ) The Rotative Level Control RL-A AD1/2* are used to detect the level of materials such as dust or granules in containers. They are supplied with plastic

More information

ISO-9001:2000 certified Aplus Finetek Sensor, Inc.

ISO-9001:2000 certified Aplus Finetek Sensor, Inc. SE3 Series Compact Rotary Paddle Point Level Sensor ISO-9001:2000 certified Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION PRINCIPLE The SE3 series is a compact rotary paddle point level sensor that uses

More information

Process Protection Motion sensors

Process Protection Motion sensors Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Application The MFA 4p detects changes in the motion and speed

More information

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on Siemens G 2017 SITRS US lamp-on Overview SITRS U1010 clamp-on non-intrusive ultrasonic flow transmitter offers maximum versatility plus battery power for portable field use. It can operate in either Wideeam

More information

Rotary Paddle Bin Monitor MODEL KA & KAX

Rotary Paddle Bin Monitor MODEL KA & KAX Setting The Standard For Supplier Excellence Rotary Paddle Bin Monitor MODEL KA & KAX Hassle-Free Housing Design - No Bolts! Industry Leading Motor Shut-off Feature Economical, Versatile Point Level Bin

More information

Continuous level measuring system NB 3000 Selection list

Continuous level measuring system NB 3000 Selection list Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview. Level Measurement Pointek CLS300 Standard Siemens AG 20 Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable

More information

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

NIVOCONT R VIBRATING ROD LEVEL SWITCHES For solids NIVOCONT R VIBRATING ROD LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES O U R P R O F E S S NIVOCONT R VIBRATING ROD LEVEL SWITCHES MAIN FEATURES Extension up

More information

Level Devices. Rotary Level Indicators Roto-Bin-Dicator

Level Devices. Rotary Level Indicators Roto-Bin-Dicator 7901 NW 107th Terrace Level Devices We offer Rotary Level Indicators, Radio Frequency Level Indicators, and Turning Fork Level Sensors. For more information please contact your Schenck Process Aftermarket

More information

Super-Safe-Plus Roto-Bin-Dicator

Super-Safe-Plus Roto-Bin-Dicator Super-Safe-Plus Roto-Bin-Dicator for your most demanding applications... Offers both mechanical and electronic sensing in one reliable Point Level Sensor... Level control with added confidence Under normal

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,

More information

Motion sensors. Milltronics MFA 4p 6/17. Overview

Motion sensors. Milltronics MFA 4p 6/17. Overview Siemens AG 2013 Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Application The MFA 4p detects changes in the

More information

Level Measurement Continuous level measurement - Capacitance transmitters

Level Measurement Continuous level measurement - Capacitance transmitters Overview Probe Applications Rod version Rod version with stilling well Cable version PFA coated cable version Extended cable with rod version Conductive liquids, slurries or solids Conductive liquids or

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,

More information

DIAMOND POINT VIBRATING PROBES

DIAMOND POINT VIBRATING PROBES DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527

More information

Level Limit Switch soliphant FTM 930/931/932/ Z

Level Limit Switch soliphant FTM 930/931/932/ Z Technical Infmation TI 042F/00/e Level Limit Switch soliphant FTM 930/931/932/ Z F Universal Application with Bulk Materials and Dust Ex Area Application The Soliphant has a wide range of safe applications

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview Benefits It is compact and light, fitting neatly into dense piping arrangements Effective separation of measurement from plant vibration Reliable measurements due to high signal to noise ratio

More information

FF03. Rotary Blade Level Switch for bulk goods. Level Measurement and Monitoring

FF03. Rotary Blade Level Switch for bulk goods. Level Measurement and Monitoring Level Measurement and Monitoring FF03 Rotary Blade Level Switch for bulk goods For bulk good with grain size up to 150 mm and bulk weight from 0,01 up to more than 2,0 t/ m³ Robust aluminium diecast housing

More information

Level limit switch Series RN 3000 / 6000 Technical information / Instruction manual

Level limit switch Series RN 3000 / 6000 Technical information / Instruction manual Rotonivo 1 Series RN 000 / 000 Table of contents Page Safety notes/ Technical support --------------------------------------------------------------------------------------------------------- Introduction

More information

Belt Scales Speed sensors

Belt Scales Speed sensors Overview is a low- to high-resolution shaft-driven speed sensor. Benefits Compact and economical Easy, low-cost installation Accurate belt speed detection Optional resolutions for measurement over a range

More information

The Mobrey product range provides reliable point level detection in a variety of dry solid applications

The Mobrey product range provides reliable point level detection in a variety of dry solid applications Product Data Sheet June 2015 IP400, Rev DG Mobrey Dry Products Level Measurement and Control The Mobrey product range provides reliable point level detection in a variety of dry solid applications The

More information

Belt Scales Milltronics belt scales

Belt Scales Milltronics belt scales Overview pplication provides continuous, in-line weighing at minimal cost. The stainless steel load cells ensure long-term, consistent, reliable measurement. The modular construction and easy assembly

More information

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUP1010 (Portable) 4/318 Siemens FI Overview Flow Measurement SITRNS F US lamp-on Siemens G 2011 Overview SITRNS FUP1010 clamp-on non-intrusive ultrasonic flow transmitter offers maximum versatility plus battery power for portable field use. It can

More information

Continuous level measuring system NB 3000 Selection list. Overview

Continuous level measuring system NB 3000 Selection list. Overview Table of contents Page Overview P2 ------------------------------------------------------------------------------------------------------------------- Specifications P3 -------------------------------------------------------------------------------------------------------------------

More information

Product Data Sheet. Damper Interface. Features

Product Data Sheet. Damper Interface. Features Damper Interface Product Data Sheet Features Damper Motor drive and limit switch monitoring integrated into a single unit Dual limit switch inputs for confirmation of damper-fully-open and damperfully-closed

More information

SITRANS FX300 4/289. System Overview. Overview

SITRANS FX300 4/289. System Overview. Overview Siemens G 2008 SITRNS F flowmeters Overview System Overview Version Single transmitter Dual transmitter Options Standard Pressure sensor Flange Pressure sensor and isola- Standard tion valve Sandwich vortex

More information

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids Technical Information Soliphant T FTM260 Level limit switch Cost-effective vibration limit switch for fine-grained solids Application Soliphant is a rugged level limit switch for use in silos containing

More information

Continuous level measuring system NB 4000 Selection list

Continuous level measuring system NB 4000 Selection list Table of contents Page Overview P2 Specification / application P3 P4 Options / Accessories P6 Dimensions / materials P7 Spare parts P9 Electrical installation P11 Subject to change. All dimensions in mm

More information

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS The VRF II Series uses radio frequency to detect the presence or absence of material in a vessel. It compensates for the load of the probe

More information

Mobrey dry products level measurement and control

Mobrey dry products level measurement and control Product Data Sheet Mobrey offer a range of technologies for reliable point-level detection in a variety of dry solid applications The Mobrey Series PLS is a paddle rotating level switch that detects high

More information

Continuous level measuring system. LevelMax. Selection Guide. Overview 2

Continuous level measuring system. LevelMax. Selection Guide. Overview 2 Table of contents Page Overview 2 ------------------------------------------------------------------- Specification / application 3 ------------------------------------------------------------------- 4

More information

Resistance thermometer with digital indicator Model TR75, battery operation

Resistance thermometer with digital indicator Model TR75, battery operation Electrical temperature measurement Resistance thermometer with digital indicator Model TR75, battery operation WIKA data sheet TE 60.75 Applications DiwiTherm Machine building, plant and vessel construction

More information

Filled System Thermometers

Filled System Thermometers illed System Thermometers Model N & NR Mechanical Thermometers ata sheet : ST/2012 The Rototherm range of filled system thermometers offer tough yet accurate instruments with rigid stems for direct mounting

More information

Bin Activators. Bin Activators. Bin Unloaders PLBB (LVT) Posibin MLB Live Bin Self Standing Static Bin/Hopper

Bin Activators. Bin Activators. Bin Unloaders PLBB (LVT) Posibin MLB Live Bin Self Standing Static Bin/Hopper in ctivators Standard in ctivator Sanitary in ctivator Pre-Steamer in ctivator LVT in ctivator in ctivators Posibins & ins Portable (IC) P Posibin in Unloaders PL (LVT) Posibin ML Live in Self Standing

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Flow sensor SITRNS FCS200 Overview Function The flow measuring principle is based on the Coriolis effect. See "System information ". Integration The complete flowmeter consists of the sensor (SITRNS FCS200)

More information

ROTARY PADDLE LEVEL SWITCHES

ROTARY PADDLE LEVEL SWITCHES Paddle switch catalogue YC-PSC01 Iss. 03 ROTARY PADDLE LEVEL SWITCES LEVEL SWITCES FOR SOLIDS YCONTROL ROTARY PADDLE LEVEL SWITC YEAR WARRANTY on the motor assembly due to unique design features:- motor

More information

Food & beverage. Oil & gas. Water & waste water

Food & beverage. Oil & gas. Water & waste water Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) are suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down

More information

SITRANS F M. Flow sensor MAG 1100 F 3/59

SITRANS F M. Flow sensor MAG 1100 F 3/59 Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to

More information

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview. SITRANS LC00 Overview Configuration Installation Build up of material or condensation in active shield area does not affect switch operation. SITRANS LC00 is an inverse frequency shift capacitance level

More information

Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508

Presentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508 Presentation, pplication Severe uty Limit Switches 0 onforming to NEM 600 and UL508 escription 9007T Mill Switches Use the 9007T Mill switches instead of other limit switches in the following applications:

More information

Model R7 Rotating Paddle Level Sensor Ideal for powders, solids, and granular material

Model R7 Rotating Paddle Level Sensor Ideal for powders, solids, and granular material NOHKEN INC Rotating Paddle Level Sensor Model R7 Rotating Paddle Level Sensor Ideal for powders, solids, and granular material Product Overview R7 is a solid level measurement sensor that is ideal to incorporate

More information

Belt Scales Speed sensors

Belt Scales Speed sensors Overview is a low- to high-resolution shaft-driven speed sensor. Benefits Compact and economical Easy, low-cost installation Accurate belt speed detection Optional resolutions for measurement over a range

More information

Weighfeeders SITRANS WW200

Weighfeeders SITRANS WW200 Introduction Overview is a low- to medium-capacity weighfeeder used for minor ingredient additives. Benefits High accuracy Ideal for low- to medium-capacity loads Fast installation, easy to clean and maintain

More information

Load Cells SIWAREX WL280 RN-S SA

Load Cells SIWAREX WL280 RN-S SA Siemens G 2015 SIWREX WL280 RN-S S Load cell Overview Design The measurement element is a ring torsion spring made of stainless steel. Two strain-gage spirals (DMS) are applied to the upper and lower faces

More information

PROCAP Capacitance Level Sensors

PROCAP Capacitance Level Sensors PROCAP Capacitance Simple. Rugged. Reliable. Triple thread screw on/off cover - No more bolts! Unsurpassed sensitivity and stability No interference from RF signals Switch selectable high/low fail-safe

More information

SITRANS F flowmeters SITRANS F C

SITRANS F flowmeters SITRANS F C SITRNS F flowmeters Siemens G 2008 Overview is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG certified version (DN 20 to DN 80 (¾ to 3 )). MC2 and MC2 hygienic are suitable

More information

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57 Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to

More information

Pressure Measurement Remote seals for transmitters and pressure gauges

Pressure Measurement Remote seals for transmitters and pressure gauges Siemens pplication The remote seals MF.. can be fitted to SITRNS P transmitters for pressure (SITRNS P, P, DSIII and P), absolute pressure (SITRNS P and DSIII) and differential pressure and flow (SITRNS

More information

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit > Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation Guided-wave

More information

Electronic Temperature Control & Bulb Well Assembly (AC)

Electronic Temperature Control & Bulb Well Assembly (AC) Electronic Temperature ontrol & ulb Well ssembly () 0916 86816 This is a line voltage single-stage electronic temperature control with singlepole, double-throw relay output and LED indication. It is designed

More information

Continuous level measurement Capacitance transmitters

Continuous level measurement Capacitance transmitters Siemens AG 2011 Level Measurement SITRANS LC00 Overview Configuration Installation Build up of material or condensation in active shield area does not affect switch operation. SITRANS LC00 is an inverse

More information

Class 1 as per EN o C to 65o C 15 kg/cm2 ( without thermowell ) 120 % of Full Scale 8 mm ½ BSP (M) Adjustable

Class 1 as per EN o C to 65o C 15 kg/cm2 ( without thermowell ) 120 % of Full Scale 8 mm ½ BSP (M) Adjustable Special Features & tex approved electrical contacts. Inert gas filled expansion system. Stainless steel case & stem With or without thermowell Silicon oil filled (optional) Standard followed EN 90. pplication

More information

Mobrey Squitch 2 Ultrasonic Liquid Level Switch

Mobrey Squitch 2 Ultrasonic Liquid Level Switch Product Data Sheet Mobrey Squitch 2 Mobrey Squitch 2 Ultrasonic Liquid Level Switch A compact, self-contained, ultrasonic gap sensor, designed for switching in clean liquids Mounting options including

More information

Resistance thermometer with digital display Model TR75, battery operation

Resistance thermometer with digital display Model TR75, battery operation Electrical temperature measurement Resistance thermometer with digital display Model TR75, battery operation WIKA data sheet TE 60.75 Applications DiwiTherm Machine building, plant and vessel construction

More information

PROCAP Capacitance Level Sensors

PROCAP Capacitance Level Sensors PROCAP Capacitance Level Sensors Simple. Rugged. Reliable. Triple thread screw on/off cover - No more bolts! Unsurpassed sensitivity and stability No interference from RF signals Switch selectable high/low

More information

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction K Pressure Controller Cataloge Code Characteristics Index K00-2 Pressure Controller Brief Introduction KC32 Screw Tube Differential Pressure Controller K01 KY10 Bellows Type Differential Pressure Controller

More information

OPTISWITCH 4000/5000. Vibration level switches for liquids

OPTISWITCH 4000/5000. Vibration level switches for liquids OPTISWITCH 4000/5000 Technical Datasheet Vibration level switches for liquids Operates up to 250 C / 480 F and 64 bar / 925 psi Pump dry-run detection High reliability due to permanent fault monitoring

More information

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) is suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down

More information

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free

More information

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,

More information

IOM. LP-100 & LP-200 Pulse Point TM Installation & Operation Manual

IOM. LP-100 & LP-200 Pulse Point TM Installation & Operation Manual IOM LP-100 & LP-200 Pulse Point TM Installation & Operation Manual CAUTION It is essential that all instructions in this manual be followed precisely to ensure proper operation of the equipment. SAFETY

More information

RIM20 Rotor Insertion Flowmeter

RIM20 Rotor Insertion Flowmeter Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

CVR-625. Compact Vibrating Rod Instruction Manual

CVR-625. Compact Vibrating Rod Instruction Manual CVR-625 Compact Vibrating Rod Instruction Manual BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS

More information

GP Rev a ( ) DCN0533

GP Rev a ( ) DCN0533 TABLE OF CONTENTS 1.0 INTRODUCTION.....3 Function Range of Application Typical Installations 2.0 TECHNICAL DATA.....5 General Dimensions Mechanical Data Electrical Data Operating Conditions 3.0 MOUNTING......8

More information

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs) Introduction Overview Devices Page Application Standards Used in / Personnel, material and fire protection, as well as protection against direct contact. SIGRES with active condensation protection for

More information

Vibrating Level Switches for Liquids & Solids HYC-VLS02 Elect. Iss. 02 SIL 2 APPROVED VIBRATING LEVEL SWITCHES FOR LIQUIDS AND SOLIDS

Vibrating Level Switches for Liquids & Solids HYC-VLS02 Elect. Iss. 02 SIL 2 APPROVED VIBRATING LEVEL SWITCHES FOR LIQUIDS AND SOLIDS Vibrating Level Switches for Liquids & Solids HYC-VLS02 Elect. Iss. 02 SIL 2 APPROVED VIBRATING LEVEL SWITCHES FOR LIQUIDS AND SOLIDS VIBRATING PROBE LEVEL SWITCHES FOR LIQUIDS AND SOLIDS PRINCIPLE OF

More information

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit > A Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview The complete flowmeter system SITRANS FC40 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according to OIML R 117 (Liquids other than water)

More information