Operating instructions According to Directive 2014/34/EU (ATEX) Annex II p group II, equipment category 1/2D

Size: px
Start display at page:

Download "Operating instructions According to Directive 2014/34/EU (ATEX) Annex II p group II, equipment category 1/2D"

Transcription

1 1. Introduction Fig.1 MAX. ( Process ) MIN. ( Ambient ) The Rotative Level Control RL-A AD1/2* are used to detect the level of materials such as dust or granules in containers. They are supplied with plastic housing with a cable gland for assembly cabling whilst. The fixing part is plastic. This device must be mounted on the external wall of the container, laterally and from the top (see fig. 1). The measuring vane must not be struck by the material to be detected. In order to avoid this, if the weight on the measuring vane and shaft is high (this is the case of heavy weight material or subject to block movements) place above the measuring vane some protection deflectors. The Rotative Level Control RL-A AD1/2* can be used with kits Rope or Pendulum shaft (see fig.3). 108x90 Pendulum shaft Shaft extensions Rope extension M20x L = L = 2000 Fig All dimension in mm Fig.3 All dimension in mm 2. Mode of operation output signal Switching part motor A low revolution synchronous induction gearing motor drives a rotating measuring vane, which is for example mounted at a container (see fig. 4). Fig.4 output signal + SW2 Switching part SW1 - SENSITIVITY ADJUSMENT motor As soon as the material level, which is to be checked, reaches the measuring vane, it is handicaped in his rotation. The synchronous induction motor is freely suspended within the housing. The caused reaction torque is used to operate a micro switch giving a suitable electrical signal and to stop the motor (see fig.5). When the vane becomes free again due to the drop in material level, a spring draws the motor back into his operating position, the micro switch returns to his inital position and the motor is switched on. The electrical output signal is then switched over (see fig. 4). Adjustment of the sensitivity: The spring is adjustable in 3 positions(see fig.5) It should be changed only if necessary. Spring + SW2 SW1 - Light : for light material; Central : suitable for nearly every material; Strong : for strong cacking material; Factory setting is Central. The spring can be changed via a small plier. SENSITIVITY ADJUSMENT Fig.5 Light Central Strong DOC. FS007EX REV. B DATE: pag. 6/ 10

2 3. Electrical data Power supply Max power dissipation Output type Connection terminal Screwed cable gland Connection diagramm Protection class 24Vdc 24Vac (50-60Hz) 48Vac (50-60Hz) 110Vac (50-60Hz) 220Vac (50-60Hz) 2.5W 4VA Floating microswitch (see connection diagram fig. 6) Connection diagrams 1 x max 1.5mm 2 1 x M20x1.5 See connection diagram (fig. 6), inside cover and datasheet I AC DC Floating microswitch Imax Vmax 2A 250V Pmax 600VA (cosn=1) 2A 300V 60W Power supply PE DC AC L N Connect the terminal with the earth of the container. Fig.6 Note : All voltages +10% / -15% 4. Mechanical data Housing Process connection Material process-connection Material vane shaft Material measuring vane Tollerance length L Plastic PA6 grey with fiberglas Enclosure IP6X to EN Bearing 1½ GAS thread or flanges on request Plastic PA6 Stainless steel Plastic PP, black mm Slide bearing, high-grade Sealing Friction clutch Pickup delay Sensitivity Speed of measuring vane Radial rotary shaft sealing Protection of the gearing of impacts of the measuring vane Approx. 1.3sec Adjustable via reset force of spring or geometry of measuring vane 1 g/min DOC. FS007EX REV. B DATE: pag. 7/ 10

3 5. Operating conditions Container over-pressure Powderdensity Feature of bulk material Maintenance -0.2bar bar Min. 100g/l Dustlike, powdery, granulated, granular Not required Temperature inside container. : -20 upto +80 (see fig. 8) Ambient of the housing. : -20 upto +60 (see fig. 8) The following informations show the maximum surface at the warmest part of the Rotative Level Control RL-A AD1/2... which can happen in failure case (according to ATEX definition). Maximun surface Maximum surface Maximum ambient in to ZONA 21 Maximum ambient in to ZONA RotoStar by AECO Inzago-MI-Italy II 1/2D Ex t IIIC T120 Da/Db 0722 DATE OF PRODUCTION Tprocess (): Tamb (): IP6X --- MODEL--- LOT NUMBER Maximum operating 6. Safety items General The Level control should only be mounted, connected and set-up by qualified staff. The qualified staff must have knowledge of protection classes, regulations and provisions for aparatus in hazardous areas. Check whether the classification ( see Marking above and marking on the unit) is suitable for the application. Switch off the mains voltage before opening the housing. Dangerous voltage! Set into operation only with closed lid of the housing. Line-up only with closed device Use a fuse for the mains voltage (max. 4A) and the signal output (max. 4A). A voltage disconnecting switch must be provided near the switch. A FI protective switch is necessary. Compare the mains voltage applied with the specifications given on the label before switching the device on. For terminal connection of the device, the local regulations must be observed. In the case of inexpert handling or handling malpractice, the electric safety of the device cannot be guaranted. Isolating signal output - mains voltage: 3kV Provide protection for relay contacts to protect the device against spikes, if inductive loads are connected. The Control level must not be modified and/or repaired. In case of a fault please contact the manufacturer. DOC. FS007EX REV. B DATE: pag. 8/ 10

4 6. Safety items Ex relevant Safety instructions for electrical installation All field wirings must have insulation suitable for at least 250Vac. The rating must be at least 90(194 F). Before opening the lid take care, that no dust deposits or whirlings are present. Cable glands and blanking elements Installation according to the regulations of the country, where the product is installed. Not used entries have to be closed with blanking elements certified for this purpose. Where applicable the factory provided parts must be used. A strain relief must be provided for the field wiring cables, when the device is installed with the factory provided cable glands. The diameter of the field wiring cable must match to the clamping range of the cable clamp. If other than the factory provided parts are used, following must be ensured: - The parts must have an approval adequate to the approval of the level sensor ( certificate and type of protection) - The approved range must be from the min. ambient of the level sensor to the max. ambient of the level sensor increased by 10k. - The parts must be mounted according to the instructions of the supplier. 7. Mounting The Rotative Level Control RL-A AD1/2* must be mounted with the thread or the flange on the container. Mounting may be vertical, oblique or horizontal. Inside container (Category 1) Outside container (Category 2) RL-A AD1/2... The electrical connections are made in accordance with the connection diagram( see fig. 6). Make sure, that the cable in the screwed cable gland is seated tightly without fail. After mounting, turn the housing in the rigth direction. The screwed cable gland must show downwards (see fig. 7). This makes sure, that the unit works fine and protects, that water enters into the housing through the screwed cable gland. When the Rotative Level Control RL-A AD1/2* is used in the open, we recommend to use the weather-protection-cover. It protects the unit against moinsture, heat, cold and prevents the formation of condensation water in the interior of the housing. Adjusting the unit at site in not required. Cut one side of the measuring vane: - In case of empty or demand detector at any rate; - To lead the vane through the mounting hole; Fig.7 Right mounting: Screwed cable gland shows downwards 8. Zone classification and Marking The Rotative Level Control RL-A AD1/2* can be used in hazardous areas according to the classification II 1/2D: group II, category 1/2D (zone 20/21), apparatus for dust atmosphere. This device are specially markerd on the type plate (see fig. 9). The approval according to 2014/34/EU directive determines the following classification: Device category to 94/9/EC Usable in zone 1D 20, 21, 22 2D 21, 22 3D * 22 (*) In case of conductive dust additional demands for installation are possible. Equipment Protection Level (EPL) Da Db Dc Fig.8 Fig.9 RotoStar (Category 2) (Category 1) by AECO Inzago-MI-Italy II 1/2D Ex t IIIC T120 Da/Db 0722 DATE OF PRODUCTION Tprocess (): Tamb (): MODEL--- LOT NUMBER Outside container Inside container IP6X DOC. FS007EX REV. B DATE: pag. 9/ 10

5 8. Approvals EU Declaration of Conformity We AECO s.r.l. Via G. Leopardi 5, Inzago (MI), Italy declare under our sole responsability that the products Product s name: Models: Rotative Level Controls ROTOSTAR RL-A AD1/2 RL - A AD1/2 24Vdc (1) RL - A AD1/2 24Vac (1) RL - A AD1/2 48Vac RL - A AD1/2 110Vac RL - A AD1/2 220Vac ATEX Marking: EC-Type Examination Certificate: Notified body of the EC-Type examination: Monitoring body per appendix IV of the directive 20014/34/EU: II 1/2D Ex t* IIIC T120 Da/Db (*)= a or b DEKRA EXAM Dinnendahlstr 9 D Bochum n 0158 CESI spa Via R. Rubattino n Milano, Italia n 0722 Tprocesso= Tambiente= to which this declaration relates, meet the requirements of the european directives 2014/34/EU - ATEX directive 2014/30/UE - Electromagnetic directive 2014/35/EU - Low voltage directive and are comply with the following armonized standards EN : 2012+A11: 2013 EN : 2009 EN : 2010 EN : 2013 EN : 1991+A1:2000 (1)= The unit meet the requirements of the directive 2014/34/EU and 2014/30/EU only. Inzago: Maurizio Scaramuzza Legal representative CUE067EX REV. A DOC. FS007EX REV. B DATE: pag. 10/10

Capanivo Series CN 4000

Capanivo Series CN 4000 Capanivo Series CN 4000 Instruction manual 010516 1 UWT GmbH Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de Scope of this instruction

More information

Level limit switch Series RN 4000 Selection list. Overview / Specification / Applications

Level limit switch Series RN 4000 Selection list. Overview / Specification / Applications Table of contents Page Overview / Specification / Applications P2 ----------------------------------------------------------------------------------------------------------- Selection P3 -----------------------------------------------------------------------------------------------------------

More information

Kondunivo Table of contents

Kondunivo Table of contents Kondunivo Table of contents Page Introduction G Technical data G Mounting G Electrical connection G Adjustment G Switching logic G Maintenance G Error search G Subject to technical change and price change.

More information

Table of contents Page Safety notes/ Technical support Introduction Technical data Approvals Options/ accessories Mounting Electrical installation 1 Settings 1 Signal output logic 1 Maintenance 1 Notes

More information

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4 Table of contents Page Specifications 2 Applications 4 ------------------------------------------------------------------------------------------------------------ CN 4020 5 Short extension length ------------------------------------------------------------------------------------------------------------

More information

Table of contents Page Safety notes / Technical support Introduction Technical data Approvals Options Mounting Electrical installation 1 Signal output 1 Sensitivity setting 1 Maintenance 1 Notes for use

More information

Continuous level measuring system NB 3000 Selection list

Continuous level measuring system NB 3000 Selection list Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------

More information

Soliswitch FTE30. Technical Information

Soliswitch FTE30. Technical Information Technical Information Soliswitch FTE30 Level limit switch Economical paddle limit switch with type-examination certificate to ATEX dust Ex-approval zone 20 Application The universal paddle level limit

More information

BMRX Series ROTARY LEVEL CONTROL

BMRX Series ROTARY LEVEL CONTROL BMRX Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0292 Rev C TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY... 4 1.0 INTRODUCTION... 5 2.0 INSTALLATION...

More information

Level limit switch Series RF 3000 Selection list

Level limit switch Series RF 3000 Selection list Table of content Page Overview P2 Applications P4 ------------------------------------------------------------------------------------------------------------- RF 3100 Standard version P6 -------------------------------------------------------------------------------------------------------------

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE

More information

Level limit switch Series RN 3000 / 6000 Selection list

Level limit switch Series RN 3000 / 6000 Selection list Table of contents Overview 2 Specifications 4 Applications 6 Page -------------------------------------------------------------------------------------------------------- RN..001 8 Short extension length

More information

Level limit switch Series RN 3000 / 6000 Technical information / Instruction manual

Level limit switch Series RN 3000 / 6000 Technical information / Instruction manual Rotonivo 1 Series RN 000 / 000 Table of contents Page Safety notes/ Technical support --------------------------------------------------------------------------------------------------------- Introduction

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

Level limit switch Series RN 3000 / 6000 Selection list

Level limit switch Series RN 3000 / 6000 Selection list Table of contents Page Overview Specifications Applications P2 P4 P6 -------------------------------------------------------------------------------------------------------- RN..001 Short extension length

More information

Level limit switch Series RN 3000 / 6000 Selection list. Overview. Specifications. Applications

Level limit switch Series RN 3000 / 6000 Selection list. Overview. Specifications. Applications Table of contents Page Overview Specifications Applications P2 P4 P6 --------------------------------------------------------------------------------------------------------- RN..001 Short extension length

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

M-0. M-0... series control, monitoring and signalling devices. Ex e

M-0. M-0... series control, monitoring and signalling devices. Ex e M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere

More information

GP Rev a ( ) DCN0533

GP Rev a ( ) DCN0533 TABLE OF CONTENTS 1.0 INTRODUCTION.....3 Function Range of Application Typical Installations 2.0 TECHNICAL DATA.....5 General Dimensions Mechanical Data Electrical Data Operating Conditions 3.0 MOUNTING......8

More information

Level limit switch Series RN 3000 / 6000 Selection list. Overview

Level limit switch Series RN 3000 / 6000 Selection list. Overview Rotonivo Table of contents Page Overview Specifications Applications P2 P4 P6 -------------------------------------------------------------------------------------------------------- RN..00 Short extension

More information

Soliswitch FTE20. Technical Information. Point level switch for granular solids

Soliswitch FTE20. Technical Information. Point level switch for granular solids Technical Information Point level switch for granular solids Applications The is a paddle switch for granular solids. Its robust and compact design makes the point level switch an ideal sensor for detecting

More information

Continuous level measuring system NB 4000 Selection list

Continuous level measuring system NB 4000 Selection list Table of contents Page Overview P2 Specification / application P3 P4 Options / Accessories P6 Dimensions / materials P7 Spare parts P9 Electrical installation P11 Subject to change. All dimensions in mm

More information

Table of contents Series VN 00 / 000 / 000 / 000 Page Safety notes / Technical support G --------------------------------------------------------------------------------------------------------- Introduction

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

Operating Instructions

Operating Instructions Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

Junction boxes for control, monitoring and control panel Ex tb

Junction boxes for control, monitoring and control panel Ex tb Junction boxes for control, monitoring and control panel - Zone 21, 22 - Category 2D - Aluminium, reinforced polyester or stainless steel enclosures - Standard or custom products Inspection window Padlockable

More information

ILED Aquarius Illuminated Windsock. User Manual

ILED Aquarius Illuminated Windsock. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 3.1 The light fitting has a type plate:... 4 3.2 The junction box has a type plate:... 5 4. Product Description...

More information

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Explosion proof electric motor For Fuel dispensing application. Main characteristic Ad-pe ed.2018/0 1 Explosion proof electric motor For Fuel dispensing application RAEL motori elettrici, since its inception in the late 60s, has assembled more than a million of explosion proof electric

More information

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators Ex d GRD-4200 Electronic earthing system - Zone 1, 2, 21, 22 - High quality electronic components - High resistance to corrosion and extreme weather - Safe and reliable over time SIL certified Level 2

More information

manual addendum ROBUS Ex

manual addendum ROBUS Ex manual addendum ROBUS Ex II 2G c IIB T4 II 2D c IIIB T135 C (Tamb = -20 +40 C) Field of application The person authorized to do the work is responsible for the zones. Conformity declaration The conformity

More information

ATEX HAZARDOUS-AREA RATED CONTAINER HEATERS AND CONTROLLER PRODUCT LAUNCH BOOK

ATEX HAZARDOUS-AREA RATED CONTAINER HEATERS AND CONTROLLER PRODUCT LAUNCH BOOK ATEX HAZARDOUS-AREA RATED CONTAINER HEATERS AND CONTROLLER PRODUCT LAUNCH BOOK Hazardous-area rated for Gas And Suitable for use in outdoor and wet environments - IP 65 Drum Heaters IBC Tank Heaters Gas

More information

DIAMOND POINT VIBRATING PROBES

DIAMOND POINT VIBRATING PROBES DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527

More information

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - C O N T R O L S T A T I O N S Moulded plastic Version for Zone 1 and Zone 21 Even under the most adverse conditions, CEAG control stations can be used and operated reliably. The enclosures consist

More information

FF03. Rotary Blade Level Switch for bulk goods. Level Measurement and Monitoring

FF03. Rotary Blade Level Switch for bulk goods. Level Measurement and Monitoring Level Measurement and Monitoring FF03 Rotary Blade Level Switch for bulk goods For bulk good with grain size up to 150 mm and bulk weight from 0,01 up to more than 2,0 t/ m³ Robust aluminium diecast housing

More information

ILED Dorado. User Manual

ILED Dorado. User Manual 10NM U-code Medium Intensity Obstruction Light Helideck Status Light 15NM U-code Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description...

More information

Flameproof Level Sensor (Flameproof F/S FP)

Flameproof Level Sensor (Flameproof F/S FP) The Deeter F/S FP is magnetic float on a reed switch or Hall Effect sensor stem for control and indication of a liquid level while in a potentially explosive atmosphere. II 1/2G 2D Ex d IIC (*) Ga/Gb Ex

More information

GP50 Vibrating Fork Level Switch. Vibrating level switch for powders and granular solids K-TEK Products

GP50 Vibrating Fork Level Switch. Vibrating level switch for powders and granular solids K-TEK Products Operating instruction manual OI/GP50-EN Rev. B GP50 Vibrating Fork Level Switch Vibrating level switch for powders and granular solids K-TEK Products Introduction This operating instruction manual provides

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

Level Measurement Point level measurement - Rotation paddle switches

Level Measurement Point level measurement - Rotation paddle switches Siemens 017 SITRNS LPS00 Overview SITRNS LPS00 is a rotary paddle switch for point level and material detection in bulk solids. enefits Proven paddle switch technology for bulk solids High integrity mechanical

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in

More information

Floodlight Range Installation Guide

Floodlight Range Installation Guide SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected

More information

Continuous level measuring system NB 3000 Selection list. Overview

Continuous level measuring system NB 3000 Selection list. Overview Table of contents Page Overview P2 ------------------------------------------------------------------------------------------------------------------- Specifications P3 -------------------------------------------------------------------------------------------------------------------

More information

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.

More information

Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66

Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66 Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS 06.0001 Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application

More information

Operating Instructions

Operating Instructions Operating Instructions Repair Light > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage and Disposal...6

More information

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to General Notes Relating to Pepperl+Fuchs Product Information. Type Z & Ex pz purge and pressurization system Features 100% automatic purge and pressurization system including purging, temperature and leakage control, alarming and system power Third party approvals

More information

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ

More information

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250, Assembly Instructions for junction boxes type: Assembly Instructions for: S1 to S / SFI1 to SFI / SFE1 to SFE S1 to S Junction Boxes MS1 to MS Junction Boxes IMPORTANT: This document should be read carefully

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5). EVI 7 S9 Solenoid System The EVI7 S9 system by AMISCO includes a wide range of solenoids, coils and operators, designed for pneumatic valves. All solenoids of this system have the guide tube with a diameter

More information

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22. PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22 News 08 PROTECT SRB s Safety relay modules with intrinsically safe monitoring

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

NIVOCONT R VIBRATING ROD LEVEL SWITCHES For solids NIVOCONT R VIBRATING ROD LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES O U R P R O F E S S NIVOCONT R VIBRATING ROD LEVEL SWITCHES MAIN FEATURES Extension up

More information

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to General Notes Relating to Pepperl+Fuchs Product Information. Type Z & Ex pz purge and pressurization system Features 100% automatic purge and pressurization system including purging, temperature and leakage control, alarming and system power Third party approvals

More information

International approvals.

International approvals. E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for

More information

introduction function electrical connection signal describtion parameter adjustment commissioning, mounting, safety items error codes

introduction function electrical connection signal describtion parameter adjustment commissioning, mounting, safety items error codes list of contents page introduction G1 function G1 technical data G2 - G3 electrical connection G4 signal describtion G5 parameter adjustment G6 - G7 commissioning, mounting, safety items G8 error codes

More information

Unused flameproof threads for cable glands have to be closed with certified plugs.

Unused flameproof threads for cable glands have to be closed with certified plugs. E X - P L U G A N D R E C E P T A C L E 1 A Metallic Design for Zone 1 The explosion-protected light metal plug and receptacle devices can be used in the areas of Zone 1 and Zone 2 at no risk of explosion.

More information

Terminal Boxes in Stainless Steel SLS**.T

Terminal Boxes in Stainless Steel SLS**.T Features Variant options Stainless steel enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 6 enclosure size options Various terminal and cable gland configurations

More information

CCAI, CCAIF, CCAIF..H

CCAI, CCAIF, CCAIF..H CCAI, CCAIF, CCAIF..H - Zone 1, 2, 21, 22 - Group IIC - Stainless steel junction boxes - Choice of 4 sizes - IP66 AISI 316L stainless steel Grub screws for opening lid Lid opening system Detail of inside

More information

Type Z & Ex pz purge and pressurization system

Type Z & Ex pz purge and pressurization system Type Z & Ex pz purge and pressurization system Features 100% automatic purge and pressurization system including purging, temperature and leakage control, alarming and system power Third party approvals

More information

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /.. d.o.o. tel. 049 222 900, fax 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE 0403.24/.. No: TEPEx.RS.077 Rev : 0 Date: 02.2016. CONTENT 1. Manufacturer

More information

Operating Instructions

Operating Instructions Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD ATEX category II 3 G, Ex zone 2 ATEX category II 3 D, Ex zone 22 For T-groove cylinders without mounting accessories Optional accessories for mounting on other cylindrical housings. One-hand mounting possible

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX ATEX Type Certification marking for type L1X-EX, T1X-EX, T2X-EX Type of protection "d" explosion-proof enclosure Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

More information

Capacitive level sensors CLS 23

Capacitive level sensors CLS 23 For level detection of electrically conductive and non-conductive liquids Compact miniature performance for direct mounting to vessels, tanks, sumps and tubes Easy setting by means of magnetic pen SIL

More information

IECEx Certificate of Conformity CESI. Annex to certificate: IECEx CES X Issue No.0 of

IECEx Certificate of Conformity CESI. Annex to certificate: IECEx CES X Issue No.0 of Prot: B2036032 IECEx Certificate of Conformity CESI CESI Annex to certificate: IECEx CES 12.0007X Issue No.0 of 2012-10-29 Applicant: Electrical Apparatus: ATOS S.p.A. via alla Piana, 57; I - 21018 Sesto

More information

Zone 1 Linear Range - Installation Guide

Zone 1 Linear Range - Installation Guide Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Technical Data. Dimensions

Technical Data. Dimensions Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS RTECK terminal boxes RTKB series IEC Ex EX010 TECHNICAL FILES CONTENTS: 1) Contents 2) General information 3) Safety information 4) Conformity to standards 5) Function 6) Technical

More information

EX-REPAIR AND MAINTENANCE RECEPTACLES

EX-REPAIR AND MAINTENANCE RECEPTACLES EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand

More information

Thermocouple For additional thermowell Model TC10-B

Thermocouple For additional thermowell Model TC10-B Temperature Thermocouple For additional thermowell Model TC10-B WIKA data sheet TE 65.02 for further approvals see page 2 Applications Machine building, plant and vessel construction Energy and power plant

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Operation & Maintenance Manual Submersible cutter pumps type DSP22 WETTERFRETTER 2.0 Explosion proof version Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398 P. O. Box 199

More information

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4 1. Introduction: This instruction manual contains important information regarding the safety instructions, installation, operation, maintenance and storage of the Guardbox limit switch boxes. The limit

More information

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T** Assembly Instructions for: S1 Assembly to S Junction Instructions Boxes for: MS1 to MS Junction Boxes Boxes MS1 to MS Junction Boxes IMPORTANT: This document should be read carefully before commencing

More information

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/ Series DBOB-Continuous Level Measuring System Bulletin L-DBOB Specifications - Installation and Operating Instructions 7-9/32 [185.00] 5-45/64 [145.00] 8-21/32 [220.00] 5-45/64 [145.00] 10-1/32 [255.00]

More information

The Mobrey product range provides reliable point level detection in a variety of dry solid applications

The Mobrey product range provides reliable point level detection in a variety of dry solid applications Product Data Sheet June 2015 IP400, Rev DG Mobrey Dry Products Level Measurement and Control The Mobrey product range provides reliable point level detection in a variety of dry solid applications The

More information

Automatic concealed bollards 275 H600 and 275 H800 with pit

Automatic concealed bollards 275 H600 and 275 H800 with pit Automatic concealed bollards 275 H600 and 275 H800 with pit Technical installation manual CE Declaration of conformity Warnings for the installer Bollard technical data Preparing and installing the bollard

More information

Braking Devices BR 230/ Assembly- and Commissioning Instructions

Braking Devices BR 230/ Assembly- and Commissioning Instructions electronic Braking Devices BR 230/400-10...400 Assembly- and Commissioning Instructions Quality is our Drive. BR 230/400-10...400 1 as per 04/10 11600.10001 Table of Contents Page 1. Safety notes 3 2.

More information

10 Load and Motor Switchgear

10 Load and Motor Switchgear 10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,

More information

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A .1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility

More information

Explosion protected terminal boxes type, GHG 72.

Explosion protected terminal boxes type, GHG 72. 1 Technical data 1.1 Plastic terminal boxes GHG 721... ATX type examination certificate BVS 13 ATX 013 X Marking acc. to 94/9/G and standard ATX x (d e mb) II T5* -55 T amb +55 Gb x (d e mb) II T6* -55

More information

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AY1X/S1139

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AY1X/S1139 ATEX category II 1 G, Ex Zone 0 ATEX category II 1 D, Ex Zone 20 For T-groove cylinders without mounting accessories Optional accessories for mounting on other cylindrical housings. One-hand mounting possible

More information

POWER CONNECTOR TERMINATION / HOOK UP PROCEDURE

POWER CONNECTOR TERMINATION / HOOK UP PROCEDURE Power POWER CONNECTOR TERMINATION / HOOK UP PROCEDURE (AI365 Rev 7 15Nov16) Hawke International UK Office, Oxford Street West, Ashton-under-Lyne, Lancashire. OL7 0NA. UK Sales: +44 (0) 161 830 6698 Technical:

More information

Product Overview. Rotary Encoders for Potentially Explosive Atmospheres (ATEX)

Product Overview. Rotary Encoders for Potentially Explosive Atmospheres (ATEX) Product Overview Rotary Encoders for Potentially Explosive Atmospheres (ATEX) December 2013 Rotary encoders for use in potentially explosive areas Introduction There are many types of applications in industry

More information

Modular Explosion Proof Brakes. IECLine rev 0

Modular Explosion Proof Brakes. IECLine rev 0 Modular Explosion Proof Brakes IECLine 2013 rev 0 Application example Standard B5 motor + VIS brake Standard B5 motor + VIS brake + gearbox unit Main Characteristics -PATENT pending design and concept

More information

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L Temperature Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L WIKA data sheet TE 65.12 for further approvals see page 2 Applications Chemical industry Petrochemical industry

More information

SERIES 54 Inductive Proximity Sensor

SERIES 54 Inductive Proximity Sensor SENSOR FEATURES > 2-wire DC sensor with minimum off-state current > ATEX-approval for zone 2 and zone 22 > High temp, UV, salt water resistant > Rugged metal base > IP66/67/69K > High impact protection

More information

Room thermostats type series TRM

Room thermostats type series TRM TRM150 Technical data Body Mounting position Max. ambient 70 C temperature Max. temperature 70 C at sensor Contact arrangement Diecast aluminium GD Al Si 12 according to DIN 1725. Resistant to ammoniacal

More information

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No

More information

Instruction Manual. Q Series 2 Motor Control Modules - OEM

Instruction Manual. Q Series 2 Motor Control Modules - OEM A382-21-880 Issue B Instruction Manual Q Series 2 Motor Control Modules - OEM Pump/ Q Motor Control Module Item Number pumping system Electrical supply 24 V d.c. control 24 V a.c. control QDP40 200-230

More information

PY, SPY; FSQC, FP; EPC; AP

PY, SPY; FSQC, FP; EPC; AP Ex d PY, SPY; FSQC, FP; EPC; AP Sockets and plugs Aluminium alloy with low copper - Group IIC content - Zone 1, 2, 21, 22 - Aluminium alloy - Ergonomic - Plugs can be used with industrial sockets Polyester

More information

ExBin-P Pressure switches 5 Pa Pa

ExBin-P Pressure switches 5 Pa Pa ExBin-P Pressure switches 5 Pa... 5.000 Pa Electrical, explosion-proof binary pressure / differential pressure switches 5 Pa...100 Pa with adjustable switch activation delay 24 VAC/DC supply voltage, potential

More information

EStrong-series Emergency Stop

EStrong-series Emergency Stop Original instructions EStrong-series Emergency Stop ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand

More information

Leading the way in hazardous areas Features EATON

Leading the way in hazardous areas Features EATON .2 Ex-escape sign luminaires EXIT for Zone 1 and Zone 21 / Exit 2 for Zone 2 and Zone 22 Moulded plastic version with LED-technique Leading the way in hazardous areas The EXIT series of explosionprotected

More information