VX-6V. Smoke Control Damper SMOKE CONTROL FUNCTION APPLICATION DESCRIPTION. in libraries of

Size: px
Start display at page:

Download "VX-6V. Smoke Control Damper SMOKE CONTROL FUNCTION APPLICATION DESCRIPTION. in libraries of"

Transcription

1 SMOKE CONTRO in libraries of EI 1 (v o) S 1500a ed i AA multi EN :11 EN :11 Certificate of Constancy of erformance 1812-CR-.../ FUNCTION The smoke control dampers are designed for smoke control systems in buildings outfitted with a one-stage evacuation scenario based on the fire-affected zone separation principle. The dampers meet the requirements for buildings where in the event of a fire the affected zone should be isolated from the other zones, and the escape routes should be protected by means of mechanical smoke control system. The performance criteria are satisfied in case of fire from inside to outside of damper as well as outside to inside or both, respectively. The dampers can be used in multi compartment smoke control systems and should be activated automatically. s installation is allowed within vertical ducts. The dampers are designed for use in systems over the range from the negative pressure of 1500 a up to a positive pressure of 500 a. DESCRITION The consists of: - rectangular casing made of galvanized steel sheet and fire resistant board - movable damper wing made of fire resistant board - combination of smoke and fire proof seals of damper wing - control mechanism. 11 SMOKE CONTRO AICATION

2 EXAME OF AICATION Corridor Corridor NEO-T s location and fire resistance according to local regulations and smoke control system design. s can manufactured with the following options: EI 60 (v i-o) S 1500a AA multi: ed -, EI60S, 1V - wing opens to the right -, EI60S, 1V + DG - wing opens to the right with actuator -, EI60S, 1V-SY - wing opens to the left -, EI60S, 2V - two wings EI 1 (v i-o) S 1500a AA multi: ed -, EI1S, 1V - wing opens to the right -, EI1S, 1V + DG - wing opens to the right with actuator -, EI1S, 1V-SY - wing opens to the left -, EI1S, 2V - damper two wings 12

3 EI 60S 1V GV GV-AG EI60S, 1V l = - 8 l = - 54 = + 65 ht = + 5 ht = + 9 ge = + 81 ge = + 84 ge = + 71 ge = + 72 with mounting frame 105 l x l GV, GV-AG or TRA r x r without mounting frame ower supply

4 EI 60S 2V GV GV-AG EI60S, 2V l = - 4 l = - 54 = / ht = + 48 ht = + 9 ge = + 76 ge = + 84 ge = + 66 ge = + 72 with mounting frame 105 l x l GV, GV-AG or TRA r x r without mounting frame ower supply

5 EI 1S 1V GV GV-AG EI1S, 1V l = - 4 l = - 64 = + 70 ht = + 48 ht = + 29 ge = + 76 ge = + 74 ge = + 66 ge = + 62 with mounting frame 115 l l GV, GV-AG or TRA r x r without mounting frame ower supply

6 EI 1S 2V GV GV-AG EI1S, 2V l = - 4 l = - 64 = /2 + 1 ht = + 48 ht = + 29 ge = + 76 ge = + 74 ge = + 66 ge = + 62 with mounting frame 115 l x l GV, GV-AG or TRA r x r without mounting frame ower supply

7 EI 60S 1V+DG GV-M EI60S, 1V DG24 l = - 66 l = - 56 = + 60 ht = + 48 ht = + 5 ge = + 69 ge = + 79 with mounting frame 105 l x l GV, GV-AG or TRA r x r without mounting frame ower supply

8 EI 1S 1V+DG GV-M EI1S, 1V DG24 l = - 66 l = - 66 = + 70 ht = + 48 ht = + 4 ge = + 69 ge = + 69 with mounting frame 115 l x l GV, GV-AG or TRA r x r without mounting frame ower supply

9 EECTRICA WIRING DIAGRAMS SMOKE CONTRO DAMER WIT EECTRO-MAGNET AND MICROSWITCES MICROSWITCES MICROSWITCES EI 24V / V C F O C F O C F O C F O SMOKE CONTRO DAMER WIT DG ACTUATOR MICROSWITCES M 24V MICROSWITCES EI 24V / V C F O C F O ower voltage Supply input EECTRO-MAGNET CARACTERISTICS 24/48 V DC impulse,5 W V AC impulse 5,5 VA ACTUATOR CARACTERISTICS Actuator type Supply voltage Maximum current Running time Motor Required time between cycles rotection class Ambient temperature normal operation DG-24 V 24/48 V DC impulse 0,8 A up s minimum 10 s I 42 o o -5 C +50 C 19

10 INSTAATION RECOMENDED INSTAATION RUES X Smoke control duct Corridor r x r l x l Smoke control duct EI60S EI1S EI60S, 1V + DG EI1S, 1V + DG 1 max 1000 mm max 1000 mm max 1000 mm 2 max 107 mm max 1041 mm max 105 mm min 176 mm min 1758 mm min 1758 mm 4 min 1800 mm min 1800 mm min 1800 mm X min 7 mm min 7 mm min 7 mm MAXIMUM EIGT OF DAMER IN FUNCTION OF CORRIDOR EIGT Corridor EI1S EI1S 2250 mm 48 mm 448 mm 0 mm 465 mm 475 mm 250 mm 5 mm 50 mm 2400 mm 575 mm 585 mm 2450 mm 60 mm 640 mm 2500 mm 685 mm 668 mm Design changes reserved. All rights reserved. GRYFIT air handling intelligence - -C ENG. Note! 1. s location and fire resistance should respect local regulations and smoke control system design requirements. 2. The maximum height of the damper max is determined assuming 4 = 1800 [mm] min and X = 2 [mm] min. 10

The VX-6 smoke control dampers are designed for smoke control systems in buildings outfitted with a one-stage

The VX-6 smoke control dampers are designed for smoke control systems in buildings outfitted with a one-stage OE CONTROL in libraries of EI 1 (v ew h owi o) 1 C 0 multi EN 66: EN 1218: Certificate of Constancy of Performance 1CPR03/ Damper tightness class: 4 Casing tightness class: C EN51:2 FUNCTION The smoke

More information

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of FIRE SAFETY Fire Valve in libraries of EI 60 (v e -o i) S EN 131-3+A1:10 EN 156:10 Certificate of Conformity 1488-CPD-02 82/W FUNCTION The fire valves are designed for buildings where in the event of a

More information

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION air handling intelligence FIRE SFETY Fire Damper in libraries of EI 10 (v e -i o) S EN 13501-3+1:01 EN 15650:0 Certificate of Conformity 1488-CPD-081/W EUROPEN PTENT PPLICTION EP 01158318 GOLD MEDL MTP

More information

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

7/S1 FIRE DAMPER PPZEN. v 2.5 (en) 7/S1 v.5 (en) FIRE DAMPER PPZEN www.klimaoprema.hr 39 TABLE OF CONTENTS Product description... Range... Fire classification according to EN 13501-3... Operating mechanisms and dimensions... Operating manual...

More information

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België Control Equipment 01616E00 Position switches are used to monitor the position of moving parts of machines and plant. Can be used in safety circuits, as the device satisfies EN 60 947-5-1/DIN VDE 0660 part

More information

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive Technical data sheet NFU Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations Torque: 10Nm Nominal voltage: AC 4... 40V DC 4...15V

More information

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410. PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

vw-wi://rl/a.en-gb.a wi:: xml?xsl=3

vw-wi://rl/a.en-gb.a wi:: xml?xsl=3 Page 1 of 13 Removing and instaing turbocharger 1 contro unit -J724- - vehices with 3.0 tr. engine Specia toos and workshop equipment required t Tester -VAS 6395/1- t Connection ead -VAS 6395/4-2- t Open-end

More information

Rectangular smoke damper (remote controlled)

Rectangular smoke damper (remote controlled) Clapets coupe-feu et Volets de désenfumage D.A.S. Organisme Certificateur AFNOR Certification - www.marque-nf.com VU10 Rectangular smoke damper (remote controlled) Rf-Technologies nv - Lange Ambachtstraat

More information

Bevent Rasch BSK Fire /04/2017

Bevent Rasch BSK Fire /04/2017 Bevent Rasch - Fire - BSK120 10/04/2017 Rectangular Fire resistance class /S Sizes from 200 x 200 mm to 1200 x 1000 mm Prefitted safety actuator 24V or 230V Available in MagiCAD CE-marked building product

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage AC/DC

More information

Fire Safety Products. Product Overview

Fire Safety Products. Product Overview Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Fire Safety Products Product Overview SAFETY PRODUCTS prevent the spread of

More information

Bevent Rasch BSK6. - Fire /04/2017

Bevent Rasch BSK6. - Fire /04/2017 Bevent Rasch - Fire - BSK6 11/04/2017 Fire resistance class EI60 / EI60S Sizes from 200 x 200 mm to 800 x 800 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product

More information

7/S5 FIRE DAMPER FD40. v 2.9 (en)

7/S5 FIRE DAMPER FD40. v 2.9 (en) 7/S v.9 (en) FIRE DAMPER FD0 www.klimaoprema.hr 69 FIRE DAMPER - FDC TABLE OF CONTENTS FIRE DAMPER FD0 7 FIRE CLASSIFICATION 7 SELECTION DIAGRAM 7 ORDERING KEY 7 DAMPER MODELS 7 FD0-M rectangular fire

More information

Combustion gas damper EKO-JB

Combustion gas damper EKO-JB EKO-JB Description The EKO-JB combustion is a Class E6 type-approved damper intended to prevent the spread of combustion gases in ventilation ducting that penetrates fire rated compartment wall or floor

More information

5/2 and 5/3 Way Valves

5/2 and 5/3 Way Valves Caracteristics to VDI 9 Pressures quoted as gauge pressure Characteristics Symbol Unit Description General Features Ceramic Spool Valve Mounting On base plate, Tube connection Base plate Port size G1/

More information

Systemair Fire Dampers

Systemair Fire Dampers Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S www.systemair.com As standard, all fire dampers are designed and certified to comply with EI-S performance attributes. fire dampers

More information

series CEVH Smoke Evacuation Damper

series CEVH Smoke Evacuation Damper series CEVH Smoke Evacuation Damper www.koolair.com Series CEVH 1 CONTENTS Description 2 Dimensions 4 Installation 5 Assembly 6 Electrical connections 7 Technical data 8 Coding 10 2 Series CEVH Description

More information

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3 SA/6/1/EN/3 Fire Dampers Type FDF Compliant to SABS (193:2004) TROX (South Africa) (Pty) Ltd. 10 Wigford Road Masons Mill Pietermaritzburg Tel. +27 (0)33 398 1006 Fax. +27 (0)33 398 1100 email : pmb@troxsa.co.za

More information

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS Rectangular fire dampers FIRE DAMPERS PL-12 PL-15 PL-18-1, PL-18-2 Fire dampers are installed in rectangular or circular ventilation ducts, at passages

More information

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

7/S6 FIRE DAMPER FDC40. v 2.9 (en) 7/S6 v.9 (en) FIRE DAMPER FDC0 www.klimaoprema.hr 8 TABLE OF CONTENTS FIRE DAMPER FDC0 87 FIRE CLASSIFICATION 87 SELECTION DIAGRAM 88 ORDERING KEY 88 DAMPER MODELS 89 FDC0-M cylindrical fire damper with

More information

Position Switches Series 8070/2

Position Switches Series 8070/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet LHK24A-SZ Modulating SuperCap linear actuator with emergency setting function and extended functionalities for adjusting air dampers and sliders in ventilation and air-conditioning

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet FA actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage

More information

Fire Dampers Catalogue

Fire Dampers Catalogue Fire s Catalogue DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) CRFD - Type A, B, CR & CO Rectangular, Round & Flat Oval UL 555 Classified 2013 For Use in Static & Dynamic Systems 3 Hour Rating Made in

More information

ESAS Smoke control damper

ESAS Smoke control damper ESAS Smoke control damper 1 Rectangular smoke control damper ESAS is specially designed to use in single fire compartment applications as a closing or as an opening damper for smoke extract purposes. ESAS

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts Halton FDR Fire Damper for Rectangular and Circular Ducts Type-approved and compliant with the EN 1366-2 and EN 13501-3 standards. Design for installation in separating concrete and masonry walls and ceilings

More information

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of spring return actuator Description Spring-return actuator for adjusting and regulating dampers and valves in air conditioning and ventilation. Torque

More information

VU120. Rectangular smoke evacuation damper. V22-EN-G 08/2017

VU120. Rectangular smoke evacuation damper.  V22-EN-G 08/2017 Organisme Certificateur AFNOR Certification - www.marque-nf.com VU120 Rectangular smoke evacuation damper. en 0749 Clapets coupe-feu et Volets de désenfumage D.A.S. Rf-Technologies nv Lange Ambachtstraat

More information

Overview of types. Technical data. Safety notes

Overview of types. Technical data. Safety notes echnical data sheet LH4A-S-P.. Linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air dampers up to approx.

More information

RVP-R- VAV controller. In explosion-proof version

RVP-R- VAV controller. In explosion-proof version VAV controller In explosion-proof version RVP-R- SMAY LLC / 29 Ciep³ownicza St. / 31-587 Cracow / Poland tel. +48 12 378 18 00 / fax. +48 12 378 18 88 / e-mail: info@smay.eu Intended use VAV control units

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V echnical data sheet SH24A-SR.. Modulating linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m 2 Actuating

More information

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3 SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage

More information

DIAL DAMPER REGULATOR SET (1/4 ) Product Data Sheet

DIAL DAMPER REGULATOR SET (1/4 ) Product Data Sheet DIAL DAMPER REGULATOR SET (/4 ) Elgen s Dial Damper Regulator Set is used for controlling the damper inside the ductwork. /4 regulator sets for dampers up to 0. Quick and easy installation Kit Components

More information

RVP-R VAV REGULATORS. Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems.

RVP-R VAV REGULATORS. Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems. RVP-R VAV REGUATORS Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems. Intended use VAV regulators are used for automatic airflow regulation

More information

Powers TM Controls SW 141 Differential Static Airflow Switches

Powers TM Controls SW 141 Differential Static Airflow Switches Powers TM Controls SW 141 Differential Static Airflow Switches Document No. 155-052P25 SW 1 0518 Description The SW 141 Airflow Switch senses static differential pressure and the diaphragm operated snap

More information

Variable Air Volume Dampers

Variable Air Volume Dampers OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control

More information

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content Solenoid interlock AZM 415-../.. 7 Appendix 7.1 Comparison of the old and new contact configurations...6 8 EU Declaration of conformity Operating instructions.............pages 1 to 8 Original 1. About

More information

SMOKE CONTROL DAMPERS

SMOKE CONTROL DAMPERS SMOKE CONTROL DAMPERS 96 - CPD - 0058 Round DKIR and Rectangular DKIS ORIGINAL INSTALLATION, OPERATION AND MAINTENANCE MANUAL EVERY SMOKE DAMPER NEEDS TO BE INSTALLED IN ACCORDANCE WITH THIS MANUAL! /

More information

Position Switches Series 8074/2

Position Switches Series 8074/2 www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,

More information

PKIR3G, PKIS, PKIS3G and PKIS3GA

PKIR3G, PKIS, PKIS3G and PKIS3GA PKIR3G, PKIS, PKIS3G and PKIS3GA Fire Dampers Fire resistance EI60S, EI90S and EI120S 1396 - CPR - 0076 1396 - CPR - 0077 1396 - CPD - 0062 Ordering codes Dimensions Type of activation PKIR3G 1) - ødn

More information

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx 4 m 2 orque 20 m ominal voltage AC/DC

More information

Systemair Fire Dampers

Systemair Fire Dampers Fire safety products 1 / 7 Systemair Fire Dampers Fire resistance class EI60S; EI90S and EI120S 1396 - CPD - 0061 1396 - CPD - 0062 Ordering codes Ordering Codes for Circular FD: Fire resistance class

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing echnical data sheet LH4A.. Linear actuators for operating air control dampers and slide valves in ventilation and air-conditioning systems For air control dampers up to approx. m Actuating force 5 ominal

More information

Minimum 18 in-lb Torque

Minimum 18 in-lb Torque CM Series Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM CMB Series - At A Glance CMB24-3 (p. 311) CMB24-3-T (p. 311) CMB120-3 (p. 313) CMB24-SR-R

More information

Rectangular smoke damper (remote controlled)

Rectangular smoke damper (remote controlled) NF-Clapets coupe-feu et Volets de désenfumage D.A.. NF 264 www.marque-nf.com VU120 Rectangular smoke damper (remote controlled) Rf-Technologies nv - Lange Ambachtstraat 40-9860 Oosterzele - Belgique -

More information

Position Switches Series 8060/2

Position Switches Series 8060/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

Technical data. Safety notes

Technical data. Safety notes echnical data sheet SM4A-S-P Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque Nm Nominal

More information

VU120. Rectangular smoke evacuation damper. V22-F 07/2015

VU120. Rectangular smoke evacuation damper.   V22-F 07/2015 Organisme Certificateur AFNOR Certification - www.marque-nf.com VU120 Rectangular smoke evacuation damper. en Clapets coupe-feu et Volets de désenfumage D.A.S. Rf-Technologies nv Lange Ambachtstraat 40

More information

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of

More information

R.A.D. Remote Activated Diffuser WIRELESS DIFFUSER CONTROL. 448 South Main Street / Verona, WI / (608)

R.A.D. Remote Activated Diffuser WIRELESS DIFFUSER CONTROL. 448 South Main Street / Verona, WI / (608) U S E R M A N U A L R.A.D. Remote Activated Diffuser WIRELESS DIFFUSER CONTROL 448 South Main Street / Verona, WI 53593-1499 / (608) 845-6411 2 Introduction The R.A.D. consists of the Actuator on the bottom

More information

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures Enclosures for hazardous areas clamped enclosures Clamped NEMA 7 classifi ed enclosures Clamped : NEMA 7 classified enclosures Safer. Faster. Easy access, lower risk and less downtime. Creative thinking

More information

Product Development and Testing An AMCA Registered Laboratory LJ Airflow: Static Pressure: Temperature: To 80,000 CFM To 50" wg To 600 F Bradner Ohio Test Facility Floor Plan I Approved to conduct performance

More information

Motorized Fire Dampers

Motorized Fire Dampers Model : OMFD-611 (Fusible link and spring return actuator) GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Static and

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SHA.. inear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. m Actuating force 45 ominal voltage

More information

S1024-2POS / S POS S2024-2POS / S POS

S1024-2POS / S POS S2024-2POS / S POS GENERAL S0-POS / S00-POS S0-POS / S00-POS SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 0/0 Nm (88/77 lb-in) FOR -POSITION CONTROL These direct-coupled damper actuators provide two-position control for:

More information

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications Medium voltage products UniSec Y800 New 24 kv air-insulated medium voltage switchgear to e-istribuzione specifications UniSec Y800 ubicles available Unit e-istribuzione specifications (Ed. 4) UniSec IS/1

More information

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point Actuators Technical data sheet Rotary drive Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor Nominal Voltage Control Damper size Damper

More information

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor echnical data sheet SHK24A Linear actuator with capacitor technology for adjusting air dampers and sliders with emergency control function and extended functionalities in ventilation and air-conditioning

More information

PSTI High Induction Diffuser

PSTI High Induction Diffuser PSTI High Induction Diffuser Barcol-ir is continuously aiming to optimize construction and quality for all equipment. Barcol-ir has the right to adjust the product specifications without any obligation

More information

HIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION

HIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION HT Er 1253 ENTRFUGAL N-LNE FANS ALATON entrifugal in-line fans for vertical or horizontal installation, suitable to extract air in residential, commercial, agricultural and industrial buildings such as

More information

The galvanic separation of the primary or actuating circuit and the load circuits

The galvanic separation of the primary or actuating circuit and the load circuits RELAY BASICS Relays are electro magnetically operated switches. An actuating current on a coil operates one or more galvanically separated contacts or load circuits. The electro mechanical relay is a remote

More information

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch echnical data sheet Damper actuator NM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up

More information

The A4 Paper Test Page 1 of (C)

The A4 Paper Test Page 1 of (C) The A4 Paper Test Page 1 of 5 2010-10-25 (C) A4 Paper Test_R1.doc Version: R1 The A4 Paper Test Without access to suitable measuring equipment, the most effective method to correctly calibrate the oven

More information

SEALED POWER TRANFORMERS BV SERIES EI30 0.6VA 2.8VA FEATURES OUTLINE DIMENSIONS

SEALED POWER TRANFORMERS BV SERIES EI30 0.6VA 2.8VA FEATURES OUTLINE DIMENSIONS ZETTLER Magnetics, Inc. COLUMBIA ALISO VIEJO, CA 266 4-360-838 FAX 4-360-83 WEB SITE: HTTP://WWW.ZETTLERMAGNETICS.COM E-MAIL: SALES@ZETTLERMAGNETICS.COM FEATURES UL & VDE CERTIFICATION SMALL PHYSICAL FOOTPRINT

More information

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor Technical data sheet GK24G- SuperCap rotary actuator with emergency setting function and extended functionalities in the IP66 protective housing for adjusting air dampers in ventilation and air-conditioning

More information

PKI-C Cartridge Fire Dampers

PKI-C Cartridge Fire Dampers Fire Safety Products / 7 PKI-C Cartridge Fire Dampers Fire resistance class EI60S, EI90S and EI0S 96 - CPD - 000 Ordering codes Fire resistance class PKI-C-EI - 60S, 90S and 0S Codes section. The thermal

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL TUB MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8. Fire safety products 1 / 8 DKISMA Systemair multicompartment rectangular smoke control dampers Resistance class EI120(v ew i o) S1500C mod AAmulti 1396 - CPR - 0112 Ordering codes Nominal dimensions Type

More information

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

Fire damper ETPR. Specifications. Product code example Fire damper ETPR Fire damper ETPR ETPR fire damper is CE marked based on product standard EN 15650:2010 and tested according to the test standard EN 1366-2. ETPR meets the requirements of fire class EI 60 S / EI 90 S.

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES A S E R I E S Catalogue 001 Directly operated solenoid valves Series A / way, 3/ way monostable, stable (with magnetic memory) Ports M5, G1/8, cartridge ø 4 The Series A solenoid valves are of the directly

More information

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR 24 Volt AC input Built in 15 second low fire start timer 0-24 Volt DC modulating output Remote temperature selection Calibration trim pot Rated for -40 F (-40 C) DFC-1 STANDARD TEMPERATURE CONTROL DFC-2

More information

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

Fire Dampers. Types FKA FRL FRK 4/1/EN/1 Fire Dampers Types FKA FRL FRK /1/EN/1 Contents Description Description... Construction... Standard Sizes Installation Details... Functional Description Product Range... Accessories... Circuit Diagrams...

More information

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch echnical data sheet Damper actuator LM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up

More information

DAMPERS LSS - R. N-6230 SYKKYLVEN, NORWAY TEL FAX

DAMPERS LSS - R. N-6230 SYKKYLVEN, NORWAY TEL FAX DAMPERS LSS - R LSS / SOD circular single blade shut off damper SSVent rectangular multiblade shut off damper S.Ventil R1OVL circular single blade weather tight damper/valve RD circular regulating damper

More information

GE Industrial Solutions. New. QuiXtra 4000ED.02. Low Voltage Distribution Boards up to 4000A. GE imagination at work

GE Industrial Solutions. New. QuiXtra 4000ED.02. Low Voltage Distribution Boards up to 4000A. GE imagination at work GE Industrial Solutions New Quitra 4000ED.02 Low Voltage Distribution oards up to 4000 GE imagination at work Quitra 4000 Quitra 4000 is a range of sheet steel system enclosures, delivered as a flat kit:

More information

D Series Ex d Stainless Steel

D Series Ex d Stainless Steel 2 Way irect Acting Solenoid Valve IIC T4/T6 Series Stainless Steel 2 and 3 Way irect Acting Solenoid Valve IIC T4/T6 2SK-CM [ FEATURES ] Integral terminal box with coil housing. Valve do not require minimum

More information

TIP-200S-20 & TIP-200S-Ex-d-20 Power unit with electrohydraulic-acting spring-return rotary actuator (Normal & Explosion Proof Type)

TIP-200S-20 & TIP-200S-Ex-d-20 Power unit with electrohydraulic-acting spring-return rotary actuator (Normal & Explosion Proof Type) TIP-200S-20 & TIP-200S-Ex-d-20 Power unit with electrohydraulic-acting spring-return rotary actuator (Normal & Explosion Proof Type) Introduction Electrohydraulic-acting Spring-return rotary actuator 90

More information

Direct Gas-Fired Make-up Air Heaters

Direct Gas-Fired Make-up Air Heaters Direct Gas-Fired Make-up Air Heaters SDM-E SERIES OUTDOOR SPECIFICATIONS MANUAL MANUFACTURED BY : BROTHERS LIMITED TABLE OF CONTENTS Summary description of the unit...4 Required burner capacity...6 Dimensions

More information

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor

More information

POSITIVE PRESSURE DAMPER PRESSURE RELIEF DAMPER KYODO-ALLIED TECHNOLOGY PTE LTD

POSITIVE PRESSURE DAMPER PRESSURE RELIEF DAMPER KYODO-ALLIED TECHNOLOGY PTE LTD POSITIVE PRESSURE DAMPER PRESSURE RELIEF DAMPER KYODO-ALLIED TECHNOLOGY PTE LTD 8 Pandan Crescent #01-06, Singapore 128464 Tel: (65) 6265 111 Fax: (65) 6265 8100 Website: www.kyodo.com.sg MODEL: KBD This

More information

Fiberseal. Flexible fire protection closures. Fiberseal Evolution-Sm Fiberseal Evolution-Sa Fiberseal-H Fiberseal-S

Fiberseal. Flexible fire protection closures. Fiberseal Evolution-Sm Fiberseal Evolution-Sa Fiberseal-H Fiberseal-S Fiberseal Flexible fire protection closures Fiberseal Evolution-Sm Fiberseal Evolution-Sa Fiberseal-H Fiberseal-S Protection concepts 1. For openings in walls How can large openings in walls be sealed

More information

lindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction

lindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction lindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction Duct and fittings Content Duct and fittings Introduction...3

More information

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in ventilation and air conditioning

More information

Metasys Zoning Package Installation

Metasys Zoning Package Installation Technical Bulletin Issue Date August 28, 2002 Metasys Zoning Package Installation Metasys Zoning Package Installation...2 Introduction... 2 Key Concepts... 3 Installation Overview... 3 Metasys Zoning Package

More information

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Telefax 0 74 63-980 - 200

More information

Operating Instructions for Models Cobra and Lynx Air and Duct Leakage Testers: (Inlet Damper and Digital Gauges)

Operating Instructions for Models Cobra and Lynx Air and Duct Leakage Testers: (Inlet Damper and Digital Gauges) Operating Instructions for Models Cobra and Lynx Air and Duct Leakage Testers: (Inlet Damper and Digital Gauges) Table of Contents Introduction Introduction.. 2 Safety Precautions Safety Precautions. 2

More information

CC /2013 Part Number A

CC /2013 Part Number A Air Conditioning System Installation Instructions CC 45 3/203 Part Number 4722A Table of contents Roof unit / Installation kit 3 Preface 3 General information 4 Preliminary steps 4 Roof cut out 4 Roof

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SF24G-S- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building

More information

BC 4.2. Tunnel Ventilation Dampers. TVD-GB-40-B Fire Rating 4Hrs As per BS476 Leakage Rating: Class-I As per UL-555S LISTED

BC 4.2. Tunnel Ventilation Dampers. TVD-GB-40-B Fire Rating 4Hrs As per BS476 Leakage Rating: Class-I As per UL-555S LISTED BC 4.2 Tunnel Ventilation Dampers TVD-GB-40-B Fire Rating 4Hrs As per BS476 Leakage Rating: Class-I As per UL-555S Type : Tunnel Ventilation Fire Damper Model : TVFD-GB-40-B;TVFD-SB-40-B Fire Rating :

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SFG- Spring return actuator with emergency function in the IP66 I protective protecti e housing for adjusting air dampers in industrial plants and in technical building installations

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

DHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser

DHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser DHL HEPA terminal filter diffuser Low turbulent flow diffuser (LTF), also suitable for exhaust Installation flush to the ceiling, also suitable for wall installation A measurement access through the diffuser

More information

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES Online data sheet i15-em03 Lock i15 Lock i15-em03 Lock i15 Lock A B C D E F actuator not supplied with delivery Ordering information Type Part no. i15-em03 Lock 6034028 The actuator has to be ordered separately.

More information

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series ACOUSTIC CABINET FANS FOR SULY AIR ALICATIONS CAIB/T RO-REG Series Introduction of fresh air to commercial offices and industrial kitchens. Acoustic cabinet fan in galvanised sheet steel with reinforced

More information

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C ELECTRIC POWER REGULATION STS converts 0 10 V signal to one time proportional and up to 3 contact. Each step must be identical in power. input output 1 2- number of steps 2 Vac, 1 VA 0 10 Vdc < 1 ma for

More information

Pressure Control, Differential Pressure Control, Type RT

Pressure Control, Differential Pressure Control, Type RT MAKING MODERN LIVING POSSIBLE Data sheet Control, Control, Type RT An RT control contains a operated single-pole changeover contact, the position of which depends on the in the inlet connection and the

More information

Timing Belt, Replacing

Timing Belt, Replacing Page 1 of 8 2004 Volvo XC70 L5-2.5L Turbo VIN 59 B5254T2 Vehicle Level Engine, Cooling and Exhaust Engine Timing Belt Service and Repair Timing Belt, Replacing Timing Belt, Replacing Timing belt, replacing

More information

Size and Configurations

Size and Configurations !!"#!""!"$%!!" &'()&('& AK Axial Flow Fans the high efficiency direct-driven fan with adjustable pitch impeller specially designed to operate with low noise emission and vibration that meets the stringent

More information