Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

Size: px
Start display at page:

Download "Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch"

Transcription

1 echnical data sheet Damper actuator LM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up to approx. m orque 5 Nm Nominal voltage AC/DC 4 V Control: Open-close or 3-point Integrated auxiliary switch echnical data Electrical data Nominal voltage AC 4 V, 5/6 Hz DC 4 V Nominal voltage range AC/DC V Power consumption In operation At rest For wire sizing nominal torque. W VA x SPD, ma... 3 (.5) A, AC 5 V (... % adjustable) Connection Motor erminals 4 mm (Cable Ø mm, three-core) erminals 4 mm (Cable Ø mm, three-core) Functional data orque (nominal torque) Min. 5 nominal voltage Direction of rotation Reversible with switch or Manual override Gearing latch disengaged with pushbutton, detentable Angle of rotation Max. 95, limited on both sides by means of adjustable, mechanical end stops Running time 5 s / 9 Sound power level Max. 35 db (A) Position indication Mechanical, pluggable Safety Protection class III Safety extra-low voltage Degree of protection IP54 in any mounting position EMC CE according to 89/336/EEC Mode of operation ype B (to EN 673-) Rated impulse voltage.8 kv (to EN 673-) Control Pollution Degree 3 (to EN 673-) Ambient temperature range C Non-operating temperature C Ambient humidity range 95% r.h., non-condensating (to EN 673-) Maintenance Maintenance-free Dimensions / Weight Dimensions See «Dimensions» on page Weight Approx. 6 g Safety notes he damper actuator is not allowed to be used outside the specified field of application, especially in aircraft or any other form of air transport. Assembly must be carried out by trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. When calculating the required torque, the specifications supplied by the damper manufacturers (cross section, design, installation site), and the air flow conditions must be observed. he device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed.

2 LM4A-S-P Damper actuator AC/DC 4 V, 5 Nm Product features Simple direct mounting Manual override Simple direct mounting on the damper spindle with a universal spindle clamp, supplied with an anti-rotation strap to prevent the actuator from rotating. Manual operation is possible with the pushbutton (the gearing latch remains disengaged as long as the pushbutton is pressed or detented). Adjustable angle of rotation High functional reliability Adjustable angle of rotation with mechanical end stops. he actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. Flexible signalization Flexible signalization with adjustable auxiliary switch (... %). Accessories Electrical installation Description Data sheet Electrical accessories S..A.. - S..A.. Feedback potentiometer P..A.. - P..A.. Mechanical accessories Various accessories (clamps, shaft extensions etc.) - Z-LM..A.. Notes Connection via safety isolating transformer. Other actuators can be connected in parallel. Please note the performance data. Wiring diagrams Open-close control 3-point control 3 S S S3 3 S S S3 Direction of rotation...%...% S S S3 S S S3 Dimensions [mm] Dimensional drawings mm 35 mm mm Damper spindle Length > > 6 < 94 Data sheet LM4A-S-P en v. 5.6 Subject to modifications

3 LM..A.. / M..A C > > 6 < Nm 8 mm 5 65 Z-PI M-LM..A../M..A.. v..7 /

4 LM..A.. / M..A D mm 6 Nm 5 65 Z-PI M-LM..A../M..A.. v.. /

5 LM..A.. / M..A.. N L N L 3 3 AC 4 V / DC 4 V DC V (LM7A..) 3 3 S S S3 3 S S S3...% LM4A.. LMC4A.. LM7A.. MC4A.. LM4A-S.. MC4A-S.. LM7A-S.. LM4AP5.. AC... 4 V N L L 3 N L L 3 S S S3 S S S3 S S S3 LM3A.. LMC3A.. MC3A.. LM3A-S.. MC3A-S.....% AC 4 V / DC 4 V U DC V DC V U DC V MP LM4A-SR.. LMC4A-SR.. LM4A-MF.. MC4A-SR.. LM4A-MP.. DC V (LM7A-SR..) SG..4 U 5 DC V DC V AC 4 V / DC 4 V (LM4A-V / VR..) 3 5 LM7A-SR.. AC... 4 V N L SG..4 U 5 DC V DC V VR LM4A-V LM3ASR.. LM3A-V / VR.. / M-LM..A../M..A.. v..

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch echnical data sheet Damper actuator NM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up

More information

Technical data. Safety notes

Technical data. Safety notes echnical data sheet SM4A-S-P Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque Nm Nominal

More information

Technical data. Safety notes

Technical data. Safety notes echnical data sheet SMA-S-P Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque m ominal voltage

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage AC/DC

More information

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx 4 m 2 orque 20 m ominal voltage AC/DC

More information

Overview of types. Technical data. Safety notes

Overview of types. Technical data. Safety notes echnical data sheet LH4A-S-P.. Linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air dampers up to approx.

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing echnical data sheet LH4A.. Linear actuators for operating air control dampers and slide valves in ventilation and air-conditioning systems For air control dampers up to approx. m Actuating force 5 ominal

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet FA actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage

More information

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz GR24A-5 / -7 GR24A-5 Rotary actuator for rotary valves GR24A-7 Rotary actuator for rotary valves Nominal torque 40Nm Nominal voltage AC/DC 24V Control Open-close echnical data Electrical data Nominal voltage

More information

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return echnical data sheet FA-S2 actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage

More information

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive Technical data sheet NFU Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations Torque: 10Nm Nominal voltage: AC 4... 40V DC 4...15V

More information

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency echnical data sheet NRA Rotary actuator for ball valves Nominal torque Nm Nominal voltage AC V Control Open-close, -point echnical data Electrical data Nominal voltage AC V Nominal voltage frequency 5/6

More information

Technical data sheet. Technical data. Safety notes

Technical data sheet. Technical data. Safety notes echnical data sheet NM24P Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..6 m 2 orque 8 Nm Nominal voltage

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SF24G-S- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building

More information

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch echnical data sheet SF24G-S-S2- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V echnical data sheet SH24A-SR.. Modulating linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m 2 Actuating

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SFG- Spring return actuator with emergency function in the IP66 I protective protecti e housing for adjusting air dampers in industrial plants and in technical building installations

More information

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool echnical data sheet LHA-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SHA.. inear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. m Actuating force 45 ominal voltage

More information

Power consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40...

Power consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40... echnical data sheet SM24P-S Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..2 m 2 orque 8 Nm Nominal

More information

Power consumption In operation At rest For wire sizing. Non-operating temperature

Power consumption In operation At rest For wire sizing. Non-operating temperature echnical data sheet DRC4G--7 Rotary actuator for butterfly valves for outdoor applications orque 90 Nm (not constant) Nominal voltage AC/DC 4 V Control: Open-close IP66 Optimum protection against moisture

More information

Non-Spring Return SMU... series

Non-Spring Return SMU... series Non-Spring Return SMU... series Product overview New Generation Non-spring return actuator Open/Close, 3-point AC 24 V 5/6 Hz, DC 24 V Auxiliary switch build-in SPD AC..24 V 5/6 Hz AC 23 V 5 Hz (Open/Close)

More information

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor Technical data sheet GK24G- SuperCap rotary actuator with emergency setting function and extended functionalities in the IP66 protective housing for adjusting air dampers in ventilation and air-conditioning

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature echnical data sheet SR24P-R Robustline rotary actuator for butterfly valves and rotary valves in Retrofit applications orque 18 Nm Nominal voltage AC/DC 24 V Control: Open-close or 3-point Optimum protection

More information

Technical data. Safety notes

Technical data. Safety notes echnical data sheet MP-S Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx 6 m orque 8 m ominal voltage

More information

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in ventilation and air conditioning

More information

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor echnical data sheet SHK24A Linear actuator with capacitor technology for adjusting air dampers and sliders with emergency control function and extended functionalities in ventilation and air-conditioning

More information

See «Overview of types»

See «Overview of types» echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m Actuating

More information

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3 SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage

More information

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet LHK24A-SZ Modulating SuperCap linear actuator with emergency setting function and extended functionalities for adjusting air dampers and sliders in ventilation and air-conditioning

More information

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point Actuators Technical data sheet Rotary drive Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor Nominal Voltage Control Damper size Damper

More information

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time Technical data sheet Rotary actuator SY-4--T Rotary actuators for butterfly valves Torque 50 Nm Nominal voltage AC 4 V Control: Open-close or -point Auxiliary switch Technical data Electrical data Nominal

More information

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of spring return actuator Description Spring-return actuator for adjusting and regulating dampers and valves in air conditioning and ventilation. Torque

More information

In operation At rest For wire sizing

In operation At rest For wire sizing NMQ24A Damper actuator for adjusting air control dampers in ventilation and air-conditioning systems for building services installations orque 8Nm Nominal voltage AC/DC 24V Control: Open-close (not made

More information

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency Technical data sheet NFG-S2-L Spring-return actuator with emergency control function for adjusting dampers in technical building installations Air damper size up to approx. 2 m² Nominal torque 10 Nm Nominal

More information

2. A E LM Form-fit versions Linear adapter ZH-LM

2. A E LM Form-fit versions Linear adapter ZH-LM Actuators for heating, ventilation, air-conditioning 2. A1-90122 - E LM Form-fit versions Linear adapter ZH-LM OEM at001707 at00205 Linear adapter ZH-LM: For LM2... damper actuators with universal spindle

More information

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time Technical data sheet Rotary actuator SY-4--T Rotary actuators for butterfly valves Torque 5 Nm Nominal voltage C 4 V Control: Open-close or -point uxiliary switch Technical data Electrical data Nominal

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency Technical data sheet DRK24A-5 SuperCap rotary actuator with emergeny control function and extended functionalities for butterfly valves Nominal torque 9 Nominal voltage AC/DC 24 V Control Open-close Design

More information

Actuators for heating, ventilation, air-conditioning 2. LM-4 -CD. Product Information Damper actuators. i

Actuators for heating, ventilation, air-conditioning 2. LM-4 -CD. Product Information Damper actuators. i Actuators for heating, ventilation, air-conditioning. LM-4 -CD Product Information Damper actuators LM i689 he complete range of damper actuators for general use in HVAC systems ype LM NM SM AM GM LF AF

More information

Minimum 18 in-lb Torque

Minimum 18 in-lb Torque CM Series Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM CMB Series - At A Glance CMB24-3 (p. 311) CMB24-3-T (p. 311) CMB120-3 (p. 313) CMB24-SR-R

More information

Nominal voltage Nominal voltage range Power consumption Wire / tranformer sizing. Connection: Motor LMU24(-S/-F) Cable 1m, 3x0.

Nominal voltage Nominal voltage range Power consumption Wire / tranformer sizing. Connection: Motor LMU24(-S/-F) Cable 1m, 3x0. LMU24(S/F/) For operation of air control dampers in HVAC system orque: 5Nm Nominal voltage: AC/DC 24V Control: Open/Close or 3point echnical data Electrical data Functional data Working conditions Nominal

More information

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω Actuators Technical data sheet Rotary actuator for control of volumetric flow without spring return Description Actuator for Volumetric flow and pressure control. Torque Motor Nominal Voltage Control Pressure

More information

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC 24 V Nominal voltage frequency Technical data sheet Globe valve actuator with emergency control function for 2-way and 3-way globe valves Actuating force N Nominal voltage AC 24 V Control 3-point Nominal stroke 2 mm Design life SuperCaps:

More information

SM24A. Technical data. Dimensions [mm]

SM24A. Technical data. Dimensions [mm] SM24A Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services orque 2Nm Nominal voltage AC/DC 24V Electrical data Nominal voltage AC 24V, 5/6Hz / DC

More information

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return.

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return. Actuators for heating, ventilation, air conditioning 2. F-2 -CD Product Information Damper actuators with spring return F i6772 Contents Selection table orque 4 Nm F24 F24-S F23 F23-S F24-3 F24-S Nominal

More information

Butterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific

Butterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific Butterfly Valves Technical Databook Version 7.2 Belimo Asia Pacific BFV and Actuators Product Range Overview and Applications BU6..Series Motorised Butterfly Valves page 4 BU6..Series Butterfly Valves

More information

VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications

VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications 1 2 3 4 5 6 7 8 Technical data sheet 227CS-024-08-V Actuator without spring return for flow- or pressure

More information

Overview of types. Technical data

Overview of types. Technical data Technical data sheet 6..S+NVFT24-MFT-E Globe valves, 2-way, with flange PN 16, actuator with emergency control function for closed hot water systems up to 150 C in district heating applications approved

More information

Damper Actuators Non-Spring Return

Damper Actuators Non-Spring Return 50 Non-Spring Return MD5A, MD10A, MD20A, MD40A The MD.A series are 2-10V modulating damper actuators designed for operating air control dampers in ventilation and air conditioning systems for building

More information

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific Globe Valves Technical Databook Version 1.2 Belimo Asia Pacific Contents Globe Valves Product Overview Max. Close-off Pressure - Globe Valve Series Globe Valve Actuators Product Overview 4 5 General Information

More information

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 00 to 40 VAC Torque min. 60 in-lb for control of damper surfaces up to 90 sq ft. Application For on/off and floating point control of dampers

More information

Characterised Control Valves with Actuators

Characterised Control Valves with Actuators Characterised Control Valves with Actuators echnical Databook Version 6.2 Belimo Asia Pacific Product Overview and able of Contents able of Contents 2 Control Valves and Actuators Product Overview 3 Characterised

More information

Characterised Control Valves with Actuators

Characterised Control Valves with Actuators Characterised Control Valves with Actuators Technical Databook Version 8.6 Belimo Asia Pacific Contents Control Valves and Actuators Product Overview 4 Characterised Control Valve 6 Sizing of Ball Valves

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 ISO 9001 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Run times: - SQM1...

More information

Versatile and Powerful

Versatile and Powerful AM Series Direct Coupled Actuator Versatile and Powerful Minimum 180 in-lb torque in a compact package. For damper areas up to 45 sq-ft* All Actuators have BDCM AM Series - At A Glance AMB(X)24-3 (p. 148)

More information

Spring-Return Damper Actuator NF24(-S)

Spring-Return Damper Actuator NF24(-S) Spring-eturn Damper Actuator NF24(-S) For operation of air control dampers that perform safety function Torque: 7Nm Nominal voltage: AC/ Control: Open/Close Integrated auxiliary switch NF24-S Technical

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB-(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 80 in-lb for control of damper surfaces up to 5 sq ft. Application For on/off and floating point control of dampers

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB4-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 80 in-lb for control of damper surfaces up to 45 sq ft. Application For on/off and floating point control of

More information

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For proportional modulation of dampers

More information

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma LMX0-SR Proportional Control, Non-Spring Return, Direct Coupled,00 to 0 VAC, for to 0 VDC and to 0 ma Torque min. 5 in-lb for control of damper surfaces up to sq ft. Application For proportional modulation

More information

NVCB 9000 series Ball Valves with Characterised Disc 2-way Flanged DN 100/DN 125/DN 150

NVCB 9000 series Ball Valves with Characterised Disc 2-way Flanged DN 100/DN 125/DN 150 NVCB 9000 series Ball Valves with Characterised Disc 2-way Flanged DN 100/DN 125/DN 150 NVCB 9000 series NENUTEC ball valves with characterised discs are especially designed and produced for applications

More information

Product Table of overview contents and table of contents. Table of contents

Product Table of overview contents and table of contents. Table of contents Product able of overview contents and table of contents able of contents Product overview he Belimo characterized control valves (CCV) he Belimo characterized control valves (CCV), notes he sizing of ball

More information

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V LMB- (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 5 in-lb for control of damper surfaces up to sq ft. Technical Data LMB- on/off-floating Power Supply VAC ±

More information

Fire and Smoke Damper Actuator product overview

Fire and Smoke Damper Actuator product overview Fire and Smoke Damper Actuator product overview Fire and Smoke protection Spring-Return Actuator BLF.. BF.. BFG.. FSLF..US FSNF..US FSAF..US Agency listing CE certification UL555 and UL555S Torque - Motor

More information

Minimum 27 in-lb torque

Minimum 27 in-lb torque LU Series Actuator Minimum 27 in-lb torque For damper areas up to 6.8 sq-ft* All Actuators have BDCM LU Series - At A Glance LUB(X)24-3 (p. 258) LUB(X)24-SR (p. 260) LUX24-MFT (p. 262) Basic Product Flexible

More information

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1. LMCB4-SR (-T) Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMCB4-SR LMCB4-SR-T HALOMO Brushless

More information

Versatile and Powerful

Versatile and Powerful LM Series Direct Coupled Actuator Versatile and Powerful Minimum 45 in-lb torque in a compact package. For damper areas up to 11 sq-ft* Actuators in bold have BDCM LM Series - At A Glance LMB(X)24-3(-S)(-T)

More information

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators The ZG-JSL jackshaft linkage is designed to easily attach to any part of a jackshaft and allow easy installation

More information

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology NMQB-MFT, NMQX-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Application For proportional modulation of dampers in HVAC systems. Actuator sizing should

More information

PN [ ] D7150NL/BAC D7200WL/BAC D7250WL/BAC D7300WL/BAC [ ]

PN [ ] D7150NL/BAC D7200WL/BAC D7250WL/BAC D7300WL/BAC [ ] Technical data sheet D7../C utterfly valve with actuator, Flange, P 16 Torque motor 160 m ominal voltage C 24...240 V / DC 24...125 V Control Open-close, modulating, communicative for mixing and diverting

More information

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology NMB (X) -MFT Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Torque min. 90 in-lb for control of damper surfaces up to sq ft. Technical Data NMB(X)-MFT Power Supply

More information

Minimum 27 in-lb Torque

Minimum 27 in-lb Torque LU Series Actuator Minimum 27 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM LU Series - At A Glance LUB(X)24-3 (p. 351) LUX120-3 (p. 353) LUB(X)24-SR (p. 355) LUX120-SR (p.

More information

MF /MS Series

MF /MS Series MF41-6153/MS41-6153 Series 24 Vac, Three-position/Modulating Non-spring Return Rotary Electronic Damper SmartX Actuators General Instructions Description The direct-coupled, 24 Vac, non-spring return electronic

More information

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating General Instructions DuraDrive MF4-653/MS4-653 Series Non-spring Return Rotary Electronic Damper Actuators 4 Vac Three-position/Modulating Description The DuraDrive direct-coupled, 4 Vac, non-spring return

More information

Characterized Control Valves Actuators. Technical Databook Ver. 2

Characterized Control Valves Actuators. Technical Databook Ver. 2 Characterized Control Valves Actuators Technical Databook Ver. 2 Product overview and table of contents Table of contents 2 Control valves and actuators Product overview The Trane Ball valves The Trane

More information

Non-Spring Return EconoDrive Floating Actuator

Non-Spring Return EconoDrive Floating Actuator MF4D-0x Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100

More information

SBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions

SBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions Operating Instructions BKS24-9A Operating Instructions BKS24-9A Table of contents Operating Instructions 1 Operating controls and indicators 2 2 Preparations for faultless commissioning and operating 3

More information

LMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V LMX4- (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMX4- LMX4--T Application For on-off and floating point

More information

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency Technical data sheet EV..R+BAC Characterised control valve (CCV) with sensor-operated flow rate or power control, power and energy-monitoring Nominal voltage AC/DC 4 V Control modulating For closed cold

More information

SAV Electronic Valve Actuator

SAV Electronic Valve Actuator Document No. 155-548 Non-spring Return, 24 Vac/dc, 3-Position Control Description The SAV Non-spring Return (NSR), Electronic Valve Actuator requires a 24 Vac/dc supply to provide three-position (floating)

More information

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V NFB4, NFB4-S, NFX4, NFX4-S On/Off, Spring Return, 4 V Torque min. 90 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection NFB4... NFX4...

More information

Air damper actuators

Air damper actuators 4 654 OPEN AIR Air damper actuators Linear version, three-position control, AC 24 V or 230 V GDB..3..2 GLB..3..2 Electric motor-driven linear actuators for three-position control, nominal linear force

More information

Air damper actuators

Air damper actuators 4 626 OpenAir TM Air damper actuators Rotary version, three-position control, AC 24 V or AC 230 V GBB13...1 GBB33...1 Electromotive rotary actuators for three-position control, nominal torque 20 m, operating

More information

AKM 105, 115: Rotary actuator for ball valve

AKM 105, 115: Rotary actuator for ball valve Product data sheet 51.363 AKM 105, 115: Rotary actuator for ball valve Improving energy efficiency Torque-dependent cut-off facility for efficient usage of energy Features For actuating 2- and 3-way ball

More information

Electrical Actuators

Electrical Actuators OEM Electrical Actuators SSY319 for valves VXG48, VXB489R, VXI48 VVP459, VXP459, VMP459, VVG549 AC 230 V operating voltage, 3-position control signal Positioning force 300 N Manual override with indication

More information

Butterfly Valves. Technical Databook. Belimo Asia Pacific

Butterfly Valves. Technical Databook. Belimo Asia Pacific Butterfly Valves Technical Databook Version 6 Belimo Asia Pacific Index BFV and Actuators Product Range Overview and Applications BU6..Series Motorised Butterfly Valves BU6..Series Butterfly Valves General

More information

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends Application Water-side control of heating and cooling systems for AHUs and water coils. Equal Percentage/

More information

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V 4 637 OpenAir TM Air damper actuators Rotary version, modulating, with spring return, AC 24 V GCA16...1 Electromotive rotary actuators, DC 0...10 modulating control signal, nominal torque 16 Nm, spring

More information

Actuators for Fire Protection Dampers

Actuators for Fire Protection Dampers 4 620 OpenAir TM Actuators for Fire Protection Dampers GNA126.1E/T. GNA326.1E/T. Rotary version, 2-position control, with spring return and ready connected temperature monitoring unit, / DC 24 48 V / AC

More information

TRF.. series spring return rotary actuators for CCV

TRF.. series spring return rotary actuators for CCV TF.. series spring return rotary actuators for CCV Spring return rotary actuators: For ball valves DN 5.. Torque: 2 Nm Modulating control TF24-S (C/DC 24 V) Floating (3-point) control TF24-2 (C/DC 24 V)

More information

Product Cross Reference

Product Cross Reference AF120 US, AF120-S US AF230 US, AF230-S US AFBUP, AFBUP-S, AFXUP, AFXUP-S Torque 133 in-lb [15 Nm] minimum 180 in-lb. [20 Nm] minimum OPERATION Running Time Noise Level < 75 seconds

More information

SAX Electronic Valve Actuator

SAX Electronic Valve Actuator SAX Electronic Valve Actuator Non-spring Return, 24 Vac, Proportional Control Technical Instructions Document No. 155-506 Description The SAX Non-spring Return (NSR), Electronic Valve Actuator requires

More information

Electromotoric actuators

Electromotoric actuators s 4 520 ACVATIX TM Electromotoric actuators SQL321B.. SQL361B.. For VKF42.. butterfly valves SQL321B.. Operating voltage AC 220 V, 2-position (SPDT) control signal SQL361B.. Operating voltage AC 220 V,

More information

LF Series Spring Return Direct Coupled Actuator

LF Series Spring Return Direct Coupled Actuator LF Series Spring Return Direct Coupled Actuator Minimum in-lb torque LF actuator For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including:

More information

Belimo is the Worldwide Leader in Fire and Smoke Actuation

Belimo is the Worldwide Leader in Fire and Smoke Actuation FS Series Fire and Smoke Direct Coupled Actuators Belimo is the Worldwide Leader in Fire and Smoke Actuation Gateway Base II, Hong Kong Belimo first produced actuators for the European fire and smoke damper

More information

GDB..3..1A GLB..3..1A

GDB..3..1A GLB..3..1A 4 624 OpenAir Air damper actuators Rotary version, three-position control, AC 24 V or AC 230 V GDB31A GLB31A Electric motor-driven actuators for three-position control, 5 / 10 Nm nominal torque, AC 24

More information

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4. TF Series Spring Return Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 4.5 sq-ft* Applications Cost effective quality and performance for a range of applications including: Classroom

More information