DIAL DAMPER REGULATOR SET (1/4 ) Product Data Sheet

Size: px
Start display at page:

Download "DIAL DAMPER REGULATOR SET (1/4 ) Product Data Sheet"

Transcription

1 DIAL DAMPER REGULATOR SET (/4 ) Elgen s Dial Damper Regulator Set is used for controlling the damper inside the ductwork. /4 regulator sets for dampers up to 0. Quick and easy installation Kit Components EDR-2XL-SS EDR-2X Qty RP-2X RP-6 RP-8 EDR-2XL Qty RP-2X RP-6XL RP-8XL Alloy Qty RP-2X-SS RP-6XL-SS RP-8XL-SS # GE05 00 GE All Elgen products are guaranteed by against defective material.

2 DIAL REGULATOR (RP-2X) Elgen s Dial Regulator is used conjunction with damper blade for controlling the damper inside the ductwork. Heavy gauge zinc plated steel regulators for low leakage applications Require only a twist of a wing nut for easy tightening and adjustments Dial shows damper position Handle is stamped from 9 GA ASTM A-653 Galvanized Steel Base is stamped from 9 GA ASTM A-653 Galvanized Steel Bolt and wing nut are Grade 2 zinc plated. # GE022 00

3 SPRING END BEARINGS Elgen s Spring End Bearing is used conjunction with damper blade or controlling the damper inside the ductwork. The spring enables easy installation Manufactured from Zinc Plated carbon steel A (In) B C D E F G L RP-6 /4 5/8 3/8 /2 /2 7/8 -/8 2-/2 RP-6XL /4 5/8 3/8 /2 /2 7/8 -/8 4 RP-7 3/8 7/8 7/6 3/4 5/8-3/6-7/6 2-/2 RP-7XL 3/8 7/8 7/6 3/4 5/8-3/6-7/6 4 # GE03 00 GE GE GE008 00

4 END BEARINGS (/4 ) Elgen s End Bearings are used conjunction with damper blade for controlling the damper inside the ductwork. Manufactured from Zinc Plated carbon steel RP-8XL-SS: A B RP-8 -/4 3 RP-8XL -7/8 3-3/4 RP-8XXL 3-5/6 5-5/8 # GE GE GE

5 DIAL DAMPER REGULATOR SET (3/8 ) Elgen s Dial Damper Regulator Set is used for controlling the damper inside the ductwork. 3/8 regulator sets for dampers up to 20. Quick and easy installation Kit Components EDR-2XL-SS EDR-3X Qty RP-3 RP-7 RP-9 EDR-3XL Qty RP-2 RP-7XL RP-9XL Alloy Qty RP-3-SS RP-7XL-SS RP-9XL-SS # GE06 00 GE All Elgen products are guaranteed by against defective material.

6 DIAL REGULATOR (RP-3) Elgen s Dial Regulator is used conjunction with damper blade for controlling the damper inside the ductwork. Heavy gauge zinc plated steel regulators for low leakage applications Require only a twist of a wing nut for easy tightening and adjustments Dial shows damper position Aluminum Handle is stamped from 9 GA ASTM A-653 Galvanized Steel Base is stamped from 9 GA ASTM A-653 Galvanized Steel Bolt and wing nut are Grade 2 zinc plated. # GE023 00

7 SPRING END BEARINGS Elgen s Spring End Bearing is used conjunction with damper blade or controlling the damper inside the ductwork. The spring enables easy installation Manufactured from Zinc Plated carbon steel A (In) B C D E F G L RP-6 /4 5/8 3/8 /2 /2 7/8 -/8 2-/2 RP-6XL /4 5/8 3/8 /2 /2 7/8 -/8 4 RP-7 3/8 7/8 7/6 3/4 5/8-3/6-7/6 2-/2 RP-7XL 3/8 7/8 7/6 3/4 5/8-3/6-7/6 4 # GE03 00 GE GE GE008 00

8 END BEARINGS (3/8 ) Elgen s End Bearings are used conjunction with damper blade for controlling the damper inside the ductwork. Manufactured from Zinc Plated carbon steel RP-9XL-SS: A B RP-9 /6 3 RP-9XL 2-3/4 5 RP-9XXL 3-3/6 5-5/8 # GE GE90 00 GE905 00

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED BC 09 Pressure Relief Dampers PRD-GAB-12B Table Of Contents S. No Description Page No 1 General Information 1 2 PRD/NRD- B10 Series 2 3 CBD - B20 Series 3 4 BDD - B30 Series 4 5 Engineering and Performance

More information

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations. Application and Design The WD300 series dampers are designed to prevent reverse airflow in horizontal exhaust applications. The WD300 features a pressure sensitive blade design that opens and remains open

More information

Motorized Fire Dampers

Motorized Fire Dampers Model : OMFD-611 (Fusible link and spring return actuator) GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Static and

More information

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper. Application The WD200 series are electrically motorized backdraft dampers that open when energized and spring return close when deenergized. The WD200 series are for horizontal or vertical mounting. Primary

More information

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

SafidDampers SPK Description. Standard Construction SPK ( Flange Type ) ( Flange Type ) SPK 30-300 Description SPK 30 - Series The single and multi-leaf s with extruded aluminum airfoil blades are designed for quite, efficient and reliable air volume control in air conditioning

More information

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty Submittal Data Model PELV-100 Penthouse Elevator Vented Hood Application and Design The PELV-100 Penthouse Elevator Vented Hood is a gravity ventilator penthouse with an 18" x 18" gasketed access door

More information

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type ) ( Flange Type ) SPK 30-100 Standard Construction FRAME: 160mm x 30mm x 1.5mm (16 Ga.) galvanized steel formed channel for flange connection. BLADES: 250mm max. width, 1.5mm (16 Ga.) galvanized steel. FINISH:

More information

Product Submittals for Project

Product Submittals for Project Product Submittals for Project May 011-1 Couplings Figure 577 Light Weight Rigid Coupling For Fire Protection Pressure Rating and Listing / Approval information contact Tyco Fire Suppression & Building

More information

VOLUME CONTROL DAMPERS

VOLUME CONTROL DAMPERS VOLUME CONTROL DAMPERS CONSTRUCTION FEATURES FRAME Roll formed 16 gauge galvanized steel channel with welded corners. X-Standard, Z-optional AXLES Roll formed 18 gauge galvanized steel. 1/2" Round chrome

More information

OWA100 OneWireless Adapter Installation of OWA 100 Remote Mounting Kit

OWA100 OneWireless Adapter Installation of OWA 100 Remote Mounting Kit OWA100 OneWireless Adapter Installation of OWA 100 Remote Mounting Kit Order Part No. Qty. Description 50056644-501 1 OWA100 REMOTE MTG KIT - 1/2NPT 50056644-502 1 OWA100 REMOTE MTG KIT - M20 Document

More information

BC 08. Sand Trap Louvers STL-AB-11A LISTED

BC 08. Sand Trap Louvers STL-AB-11A LISTED BC 08 Sand Trap Louvers STL-AB-11A Table Of Contents S. No Description Page No 1 General Information 1 2 Various Models 2 3 STL - B-10 Series 4 STL - BC-20 Series 3 4 5 6 STL - B-30 Series STL - B-40 Series

More information

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL) Commercial dampers of the U range are designed to control or shut off ductworks with airtightness classifi cation going from non-classifi ed to class 4 according to EN1751. The handling and installation

More information

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in. R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and

More information

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator.

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator. POWERS Controls No. 6 Pneumatic Damper Actuator Technical Instructions AP 331-3 331-2793 Actuator 331-2857 Actuator with Clevis and Pin 331-3012 Extended Shaft and Frame Mounting Description The POWERS

More information

Couplings. Ductile Iron Housing Specifications. Coatings. Gasket Specifications. Bolt/Nut Specifications

Couplings. Ductile Iron Housing Specifications. Coatings. Gasket Specifications. Bolt/Nut Specifications Figure 71 Flange Adapters (ANSI Class 5/150) The Figure 71 Flange Adapter is capable of pressures up to 300 psi (20,7 bar) depending on pipe size and wall thickness. It provides a direct transition from

More information

Access Doors. Sandwich Access Doors Quick and Easy. Industries, Inc. ACCESS DOORS

Access Doors. Sandwich Access Doors Quick and Easy. Industries, Inc. ACCESS DOORS D U C T M A T E Access Doors ACCESS DOORS Sandwich Access Doors Quick and Easy Advanced pressure vessel design Insulated, Uninsulated and Specialty Metals No frame to install No measuring (self-adhesive

More information

DURO DYNE EAST CORP. Bay Shore, NY DURO DYNE MIDWEST Fairfield, OH DURO DYNE WEST Santa Fe Springs, CA DURO DYNE INTERNATIONAL Bay

DURO DYNE EAST CORP. Bay Shore, NY DURO DYNE MIDWEST Fairfield, OH DURO DYNE WEST Santa Fe Springs, CA DURO DYNE INTERNATIONAL Bay DURO DYNE EAST CORP. Bay Shore, NY 11706 DURO DYNE MIDWEST Fairfield, OH 45011 DURO DYNE WEST Santa Fe Springs, CA 90670 DURO DYNE INTERNATIONAL Bay Shore, NY 11706 MULTI-BLADE DAMPER HARDWARE NEVA-BIND

More information

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and

More information

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations. Model Application The is a leakage rated modulating smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper

More information

RD-2000 Round Control Dampers

RD-2000 Round Control Dampers RD-000 Round Control Dampers Product Bulletin Code No. LIT-8105 Issued February 5, 010 Supersedes July, 009 Johnson Controls provides top-quality, low-leakage RD-000 Round Control Dampers for use in Heating,

More information

SECTION PIPE HANGERS AND SUPPORTS

SECTION PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

RA-2000 Airflow Measuring System

RA-2000 Airflow Measuring System RA-2000 Airflow Measuring System Product Bulletin Code No. LIT-1201677 Issued May 2016 Refer to the QuickLIT website for the most up-to-date version of this document. Since 1905, Johnson Controls has provided

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual Document 483514 SMOKE DAMPERS SMD-XXX and SMDR-XXX Series Leakage Rated Smoke Dampers Vertical and Horizontal Mount Please read and save these instructions

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

PART MATERIAL FINISHING. Frame Carbon steel Painted or galvanised

PART MATERIAL FINISHING. Frame Carbon steel Painted or galvanised FDO A0(A0) Fire Damper FDO in picture with flanges (available as an option) Halton FDO fire dampers are type-approved class A0(A0) fire dampers for use in marine and offshore ventilation systems. The FDO

More information

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations. Application Model is a leakage rated modulating smoke damper with 3V style blades. The has been qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operational closure in emergency smoke control

More information

VAHU Vertical Air Handling Unit

VAHU Vertical Air Handling Unit 500 to 5,400 CFM @ up to 6.00" TSP 2" double wall construction, perforated or solid lined 18 gauge G90 galvanized steel cabinet 4 standard cabinet sizes available Internally isolated direct drive plug

More information

style vision & miscellaneous miscellaneous section section INDUSTRIAL, VEHICULAR & SPECIALTY SYSTEMS

style vision & miscellaneous miscellaneous section section INDUSTRIAL, VEHICULAR & SPECIALTY SYSTEMS miscellaneous vision & style miscellaneous INDUSTRIAL, VEHICULAR & SPECIALTY SYSTEMS WE RE CHANGING THE FUTURE EBERHARD INDUSTRIAL, VEHICULAR & SPECIALTY SYSTEMS 311 miscellaneous No. 16377 No. 16858 Carb

More information

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers Model : OSTL GI 341 Description: OPTIMA make Sand Trap Louver is used as pre-filter for the protection of air conditioning plants in area exposed to extreme levels of industrial pollution. It has a high

More information

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS 96 97 SD SERIES SD for Use in Dynamic Systems Types Galvanized Steel Construction as Standard.. Sleeve Type, Model: SD - 0-00. Circular Type, Model: SD - 50-00. Oval Type, Model: SD - 60-00

More information

RM-1200 Slim Round Control Damper

RM-1200 Slim Round Control Damper RM-1200 Slim Round Control Damper Product Bulletin Code No. LIT-12011358 Issued June 16, 2008 Since 1905, Johnson Controls has developed and refined air control products by providing the highest quality

More information

Series 50 Full Port Flanged Ball Valves

Series 50 Full Port Flanged Ball Valves USA 800-766-0076 Fax 33-890-4456 www.smithcooper.com www.sharpevalves.com Los Angeles, CA Chicago, IL Atlanta, GA Vancouver, WA Houston, TX Design Features ASME B6.34 Design Full port, split body design

More information

TABLE OF CONTENTS BURNDY. Hardware. DURIUM Hardware Bolts Nuts Flat Washers Split Lockwashers Internal Tooth Lockwashers D-2 D-3 D-3 D-3 D-3

TABLE OF CONTENTS BURNDY. Hardware. DURIUM Hardware Bolts Nuts Flat Washers Split Lockwashers Internal Tooth Lockwashers D-2 D-3 D-3 D-3 D-3 URNDY DURIUM olts Nuts Flat Washers Split Lockwashers Internal Tooth Lockwashers TALE OF CONTENTS D-2 D-1 Aluminum olts Nuts Flat Washers Split Lockwashers Galvanized Steel olts Nuts Flat Washers Internal

More information

1004D3/1005E3 API Bottom Loading Coupler. 1005E3 Small handles used throughout Europe 1004D

1004D3/1005E3 API Bottom Loading Coupler. 1005E3 Small handles used throughout Europe 1004D 1004D3/1005E3 API Bottom Loading Coupler H32094PA The 1004D3 is the standard in drip-less bottom loading couplers and a proven performer at major oil terminals worldwide. The 1004D3 mates with all 4 bottom

More information

Armoured Cable/Flex. Conduit

Armoured Cable/Flex. Conduit Armoured Cable/Flex. Conduit Connectors Fittings & Accessories Grounding Trade Clamping Range Suggested Application Flex. Cat. No. Size min. max. AC90 (BX) Conduit CI70 CI71 / CI73 CI2210 / CI2236 L-16

More information

1541/1543 Series. Consolidated * Valves. Safety Valve

1541/1543 Series. Consolidated * Valves. Safety Valve GE Oil & Gas Technical Specifications 11/2014 Consolidated * Valves 1541/1543 Series Safety Valve Designed for steam and other compressible fluids, these valves are most commonly used in pharmaceutical,

More information

WINNING ELECTRICAL CO., LIMITED

WINNING ELECTRICAL CO., LIMITED A silicone polymer line post insulator mainly consists of a core rod (ECR type or FRP type), silicone rubber housing and metal end fittings. Usually, polymer line post insulators are mounted to a supporting

More information

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Sidewall Propeller Fans Direct Drive. Exhaust / Supply Sidewall Propeller Fans Direct Drive / February 2009 Sidewall Propeller Fans Greenheck s sidewall propeller fan line is the ideal choice for factory and warehouse applications where high volumes of air

More information

CFSD Series. Product Description

CFSD Series. Product Description COMBINATION FIRE AND SMOKE DAMPER 1-1/2 HR LEAKAGE RESISTANCE CLASS II 250 O F FILE NO: R22165 Product Description Combination Fire / Smoke dampers provide an automatic means of localizing areas of smoke

More information

ATEX 94/9/EC SIL3 IEC GOST-R TYPE APPROVAL

ATEX 94/9/EC SIL3 IEC GOST-R TYPE APPROVAL ATEX 94/9/EC SIL3 IEC 61508 GOST-R TYPE APPROVAL 95 90 75 Stroke 15 0 4. Universal and anti-blowout drive shaft It permits an easy conversion from parallel to diagonal square and vice versa. It is also

More information

Product Catalog. Rev. 612 r1

Product Catalog. Rev. 612 r1 Product Catalog Rev. 612 r1 PIPE FITTINGS CONDUIT FITTINGS PRODUCT CATALOG Pipe Nipples Welded and Seamless Carbon Steel 2 Pipe Nipples Welded and Seamless Stainless Steel 3 Pipe Nipples End Finishes 4

More information

Urethane. Ralphs-Pugh Urethane Products

Urethane. Ralphs-Pugh Urethane Products Ralphs-Pugh Products elastomers are unique because they combine many of the advantages of rigid plastics, metals and ceramics with the elasticity of rubber. resists abrasion and reduces the affects of

More information

PC-125x Counter-Balanced Backdraft Damper

PC-125x Counter-Balanced Backdraft Damper PC-15x Counter-Balanced Backdraft Damper Product Bulletin Code No. LIT-101180 Issued April 7, 015 Refer to the QuickLIT Web site for the most up-to-date version of this document. Since 1885, Johnson Controls

More information

87/88 Pneumatic Multi-Spring Diaphragm Actuators

87/88 Pneumatic Multi-Spring Diaphragm Actuators GE Oil & Gas Technical Specifications 05/2013 Masoneilan * Valves 87/88 Pneumatic Multi-Spring Diaphragm Actuators Actuator air action can be changed in the field for increased flexibility and reduced

More information

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model FSD-212. Combination FIRE SMOKE DAMPERS R APPLICATION Model is a combination fire smoke damper with 3V style blades. The has been qualified to 2000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operation and dynamic closure in emergency fire smoke

More information

LOW LEAKAGE VOLUME CONTROL DAMPER

LOW LEAKAGE VOLUME CONTROL DAMPER LOW LEAKAGE VOLUME CONTROL DAMPER On Time Delivery According to Standard Customization Quality Cooperation LOW LEAKAGE VCD CATALOG REV 00 APRIL 2018 2017_04_08 ABOUT US Sharqawi Air distribution systems

More information

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating. Application Model is a combination fire smoke damper with 3V style blades. This model is designed for operation and dynamic closure in emergency fire smoke situations. It is rated for airflow and leakage

More information

Blast Protection Damper

Blast Protection Damper Protection Damper plate shown as transparent height width 250mm wide 6.35mm thick blast plate bolted to damper frame 178mm 250mm standard depth 76mm standard flange Application The damper is designed for

More information

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features Model Application The is a leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper and smoke

More information

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations. Application Model is a leakage rated smoke damper with 3V style blades. The has been qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operational closure in emergency smoke control situations.

More information

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features Application Model is a high performance combination fire smoke damper with Class I leakage. High strength airfoil blades ensure the lowest resistance to airflow in HVAC systems with velocities to 4000

More information

advanced FLOW engineering Instruction Manual P/N: Make: Cadillac Model: CTS-V Year: Engine: V8-6.2L (sc)

advanced FLOW engineering Instruction Manual P/N: Make: Cadillac Model: CTS-V Year: Engine: V8-6.2L (sc) advanced FLOW engineering Instruction Manual P/N: 52-74207 Make: Cadillac Model: CTS-V Year: 2009-2015 Engine: V8-6.2L (sc) Please read the entire instruction manual before proceeding. Ensure all components

More information

Powers Controls No. 6 Pneumatic Damper Actuator

Powers Controls No. 6 Pneumatic Damper Actuator Document No. 152-013P25 Powers Controls No. 6 Pneumatic Damper Actuator OEM Literature Basic Actuator Typical Actuator with Clevis and Pin Actuator with Extended Shaft and Frame Mounting Accessories Description

More information

Thermal Isolation. Break

Thermal Isolation. Break Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade will minimize the transfer of thermal energy and reduces condensation.it

More information

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary 14B-2 Type M3 Hookstick Disconnect Switches Up to 38kV 0 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch. It is for manual switching

More information

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL) CODIFICATION CONSTRUCTION Commercial dampers of the U range are designed to control or shut off ductworks with airtightness classifi cation going from non-classifi ed to class 4 according to EN1751. The

More information

When Time is Everything... We Manufacture in Days - Not Weeks!

When Time is Everything... We Manufacture in Days - Not Weeks! When Time is Everything... We Manufacture in Days - Not Weeks! DAMPERS ACCESS DOORS LOUVERS July 2014 Specializing In Products For The HVAC Industry 763-783-7173 fax: 763-785-6977 1-800-297-9360 Customer:

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 461338 SMOKE DAMPERS SMD-XXX, SMD-XXXEF, SMD-XXXM, SMD-XXXV, SESMD-XXX, SSSMD-XXX, SMDR-XXX, SESMDR-XXX, and SSSMDR-XXX Series Leakage Rated Smoke Dampers Vertical and Horizontal Mount Installation,

More information

AL-Maraj Central A/C Systems Accessories Mfg Co.

AL-Maraj Central A/C Systems Accessories Mfg Co. AL-Maraj is one of the renowned Manufacturer, Stockist and Supplier of all kinds of HVAC products, Ducting accessories, Pipe support system, Electro-mechanical and A/C Accessories in U.A.E since 2000.

More information

Model # 42-RDS. 2/28/2017 Page 1 of 11

Model # 42-RDS. 2/28/2017 Page 1 of 11 Model # 42-RDS 2/28/2017 Page 1 of 11 /28/2017 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

Air Measuring Products AMD AMS IAQ

Air Measuring Products AMD AMS IAQ Air Measuring Products AMD AMS IAQ January 1 2012 Air Measuring Products Why is outside air measurement important? There are many significant benefits to monitoring outside air volumes. By measuring the

More information

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 48 /1200 in a variety of straight and reducing styles. Most standard fittings are cast of durable

More information

AL/ST AIR GRILLES WITH MOBILE VANES. Intended use: AL/ST type are intended for using in low- and mediumpressure ventilation systems.

AL/ST AIR GRILLES WITH MOBILE VANES. Intended use: AL/ST type are intended for using in low- and mediumpressure ventilation systems. AL/ST AIR GRILLES WITH MOBILE VANES Intended use: AL/ST type are intended for using in low- and mediumpressure ventilation systems. Intended use Ventilation grilles AL/ST type are intended for using in

More information

80UA2.75 (UA-80-8) parts list as Excel-spreadsheet. Tsurumi Europe GmbH

80UA2.75 (UA-80-8) parts list as Excel-spreadsheet. Tsurumi Europe GmbH 80UA.75 (UA-80-8) data sheet parts list exploded view dimensional drawing free standing type dimensional drawing TOS-type sectional drawing free standing type sectional drawing TOS-type performance curve

More information

FSD60/MFSD60 Multi-blade Fire Damper

FSD60/MFSD60 Multi-blade Fire Damper DAMPER FSD60/MFSD60 Multi-blade Fire Damper Tested and conform to Tested and conform to BS476:Part20:1987 The ASLI Multi-Blade Fire Dampers have been developed to provide the versatility required for today

More information

Rittling Econoline Enclosures

Rittling Econoline Enclosures Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Rittling Econoline Enclosures Submittal Data, English Language, IP Units Submittal data Project Job number Architect Performance

More information

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers Control s Model FDCB (Opposed Blade) FDHB (Parallel Blade) Aluminum Low Leakage Control s Frame:.081 extruded aluminum Blades:.125 extruded aluminum Bearings: bronze oilite Linkage: *concealed in frame

More information

Model FSD-331 Combination Fire Smoke Dampers

Model FSD-331 Combination Fire Smoke Dampers R APPLICATION Model is a high performance combination fire smoke damper with class I leakage. High strength airfoil blades ensure the lowest resistance to airflow in HVAC systems with velocities to 4000

More information

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating R APPLICATION Model FSD-211 is a combination fire smoke damper with 3V style blades. The FSD-211 has been qualified to 2000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operation and dynamic closure in emergency

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.

More information

CHAIN SPECIFICATIONS

CHAIN SPECIFICATIONS CHAIN SPECIFICATIONS Peerless Industrial Group, Your Link to Quality, Strength & Service Since 1917 Peerless, established as a manufacturer of tire chains in 1917 eventually expanded into hardware and

More information

PED 97/23/EC ATEX 94/9/EC SIL3 IEC GOST-R TYPE APPROVAL

PED 97/23/EC ATEX 94/9/EC SIL3 IEC GOST-R TYPE APPROVAL PED 97/23/EC ATEX 94/9/EC SIL3 IEC 61508 GOST-R TYPE APPROVAL 95 90 75 Stroke 15 0 4. 5. - 5 Universal and anti-blowout drive shaft It permits an easy conversion from parallel to diagonal square and

More information

Tire Changer Information

Tire Changer Information monty TIRE CHANGERS Tire Changer Information Model Number: Serial Number: Purchase Date: Sales Representative: Model Number: Serial Number: Purchase Date: Sales Representative: Model Number: Serial Number:

More information

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 60"/1500 in a variety of straight and reducing styles. Most standard fittings are cast of durable

More information

SCREWED BONNET NEEDLE VALVES

SCREWED BONNET NEEDLE VALVES SCREWED BONNET NEEDLE VALVES H-99 SERIES FEATURES n Blowout-Proof Stem n MAWP* up to 1, psi (69 bar) n MAWT* up to 648 C (12 F) n End connection size range: to 1" or to 25mm n Flow Coefficient (Cv) to1.5

More information

MAH. Modular Air Handling Unit

MAH. Modular Air Handling Unit MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally

More information

Series FS50 Fire Safe API 607 4th Edition Full Port Flanged Ball Valves

Series FS50 Fire Safe API 607 4th Edition Full Port Flanged Ball Valves USA 800-766-0076 Fax 33-890-4456 www.smithcooper.com www.sharpevalves.com Los Angeles, CA Chicago, IL Atlanta, GA Vancouver, WA Houston, TX Design Features Fire Safe API 607 4TH Edition flanged valves

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

UPS32-60 F B 1x V PN6/10

UPS32-60 F B 1x V PN6/10 GRUNDFOS DATA BOOLET UPS32-60 F B 1x230-240V PN6/10 Grundfos Pump 96401797 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/upsb2/96401797/ups-32-60-f-b.html

More information

BAIRD Wall Mounting System WL-2(23")

BAIRD Wall Mounting System WL-2(23) BAIRD Wall Mounting System WL-2(23") The WL-2(23") Wall Mounting System is engineered to handle up to and including a 10' (3.0M) antenna. The WL-2(23") has a 23" offset from the wall to the mast. The customer

More information

Hinges. Truckline Inc. Call Us at Tel: HINGES 8-1. Truck & Trailer Body Parts Mfg. & Sales

Hinges. Truckline Inc. Call Us at Tel: HINGES 8-1. Truck & Trailer Body Parts Mfg. & Sales ` Hinges Aluminum Hinges Stainless Steel Hinges Galvanized Steel Hinges HINGES 8-1 DOOR Hinges TL-Hinge-22-00407 TL-Hinge-22-01047 TL-Hinge-22-01036 TL-Hinge-22-01046 TL-Hinge-22-01041 TL-Hinge-22-01043

More information

SC series(twist drill) for machining of cast iron, Al alloy

SC series(twist drill) for machining of cast iron, Al alloy C Tools (twist drill) for machining of cast iron, Al For materials with short chips such as cast iron, silicon-aluminum, etc. Cutting edge and shank with same. tools (twist drill) 2.0 2. 2.8.0 type 110SC0-0200

More information

Air Moving Products & Accessories. air Catalog. featuring...gates Belts FAN BLADES BLOWER WHEELS ACCESSORIES V-BELTS ADAPTER HEX HUBS ETC.

Air Moving Products & Accessories. air Catalog. featuring...gates Belts FAN BLADES BLOWER WHEELS ACCESSORIES V-BELTS ADAPTER HEX HUBS ETC. air Air Moving Products & Accessories 2006 Catalog featuring...gates Belts FAN BLADES BLOWER WHEELS ACCESSORIES V-BELTS ADAPTER HEX HUBS ETC. IR MARS AIR MOVING COMPONENTS AIR MOVING COMPONENTS AN BLADES

More information

GRADE 2 ELEVATOR BOLTS* Inch Series STEEL ZINC STAINLESS. Weight/ Boxes/ Full Case. Full Case

GRADE 2 ELEVATOR BOLTS* Inch Series STEEL ZINC STAINLESS. Weight/ Boxes/ Full Case. Full Case NO. 1 NORWAY FLAT COUNTERSUNK HEAD - 20 x 3/4 - -1/2-3/4-20 x 2-20 x 2- - 20 x 2-1/2-20 x 2-3/4-20 x 3-18 x 3/4-18 x 1-18 x 1-3/4-18 x 2-18 x 2- - 18 x 2-1/2-18 x 2-3/4-18 x 3-16 x 1-16 x 1- - 16 x 1-1/2-16

More information

GV-A Manufactured by Germany s Elster GmbH High-Performance Gas Solenoid Valve for Industrial Applications

GV-A Manufactured by Germany s Elster GmbH High-Performance Gas Solenoid Valve for Industrial Applications No. CP-SS-1880E GV-A Manufactured by Germany s Elster GmbH High-Performance Gas Solenoid Valve for Industrial Applications Overview The GV-A High-Performance Gas Solenoid Valve for Industrial Applications

More information

HCD-230 Industrial Control Damper

HCD-230 Industrial Control Damper Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

Powers Controls No. 4 Pneumatic Damper Actuator

Powers Controls No. 4 Pneumatic Damper Actuator Document No. 152-012P25 Powers Controls No. 4 Pneumatic Damper Actuator OEM Literature Pivot Mount Actuator with Clevis, Clevis Pin, and Hitch Pin Clip Actuator with Fixed Bracket Mounted Actuator with

More information

DOUBLE BOLT CLAMPS G38 DOUBLE BOLT CLAMPS ( 3 4" - 2") G38W SPIRAL DOUBLE-BOLT CLAMP G38 DOUBLE BOLT CLAMPS (2 1 2" - 17")

DOUBLE BOLT CLAMPS G38 DOUBLE BOLT CLAMPS ( 3 4 - 2) G38W SPIRAL DOUBLE-BOLT CLAMP G38 DOUBLE BOLT CLAMPS (2 1 2 - 17) DOUBLE BOLT CLAMPS These double-bolt clamps are made from plated ductile iron. In the smaller sizes (3 4" to 2") they are popular for hydraulic suction lines, while larger clamps are often used for irrigation

More information

makes sure products are delivered Products are offered in steel,

makes sure products are delivered Products are offered in steel, Residential Construction Features Residential Registers, Grilles & Diffusers No one satisfies the demands for For example: an electro-deposition air distribution solutions better than paint creates a flawless

More information

U2 PUMP PARTS PRICE LIST

U2 PUMP PARTS PRICE LIST ITEM 1 7 8 9 PUMP 180-U2 Pump Body 1 See Note 1 1 180-U2 Pump Body with Flush 1 See Note 1 1 184-U2 Pump Body 1 See Note 1 1 184-U2 Pump Body with Flush 1 See Note 1 1 220-U2 Pump Body 1 See Note 1 1 220-U2

More information

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42V Air Measuring Station with VCD-42V Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) 14 ga. (2mm) Frame Type 5 in. x 1 in. hat channel - Blade

More information

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper Application and Design W x H Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness External Minimum Size 16 ga. (1.5mm) Internal Single Section Maximum Size Multiple

More information

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S V41706 VC Series Volume Control Dampers Roll formed steel blades with three material options DW144 compliant Flanged models with 65mm deep mechanically fixed casings Rectangular spigotted models with 85mm

More information

Fabricated Tee Strainers Style T & TQ; 150#, 300# and 600# Flanged or Butt Weld Connections...6 Technical Data...7

Fabricated Tee Strainers Style T & TQ; 150#, 300# and 600# Flanged or Butt Weld Connections...6 Technical Data...7 07/1 Fabricated Strainers Fabricated Y Strainers Style FSA & FSSA; 10#, 00# and 600# Flanged or Butt Weld Connections... Technical Data... Style FSA & FSSA; 900#, 100# and 00# Flanged or Butt Weld Connections...*

More information

Overhead transmission lines Tension clamp

Overhead transmission lines Tension clamp SVENSKA KRAFTNÄT T~ SWEDISH NATIONAL GRID UNIT, BUSINESS AREA AFL, Asset Management Lines OUR REFERENCE TR05-06E DATE 2016-06-09 CONSULTÅTIONS m /j(j TECHNICAL GUIDELINE REVISION 3 Td APPROVED Overhead

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

CURTAIN TYPE FIRE DAMPER

CURTAIN TYPE FIRE DAMPER MODEL: IBD-2 / IBD-2H STANDARD CONSTRUCTION FIRE RATING UL 555 1-1/2 hours UL classification damper SS: 4 hours rating classification damper NOTES Damper s dimension is usually about 10 mm smaller than

More information

Materials of Construction Cast Iron Bronze Cast Iron Stainless Stainless Stainless Neoprene Ni-Resist A * A A

Materials of Construction Cast Iron Bronze Cast Iron Stainless Stainless Stainless Neoprene Ni-Resist A * A A Assembly Parts Type ACV & AEV Vertical Condensate Unit Steel Recivers with Type 6 - Bulletin - 910 1 * 2 * 11 * 26 * 28 * 32 40 * 65 * 73 * 80 Casing Impeller Casing Cover Impeller Screw Impeller Screw

More information

Distributed By: M&M Control Service, Inc

Distributed By: M&M Control Service, Inc Fabricated Strainers Fabricated Y Strainers Style FSA & FSSA; 150#, 300# and 600# Flanged or Butt Weld Connections...2 Technical Data...3 Style FSA & FSSA; 900#, 1500# and 2500# Flanged or Butt Weld Connections...*

More information

Cable Connection (at damper) Damper in Opened Position. (Side View) Model FQAA opposed blades BCW. Model BO-300, BO-896, BO-896-P

Cable Connection (at damper) Damper in Opened Position. (Side View) Model FQAA opposed blades BCW. Model BO-300, BO-896, BO-896-P Cable Operated s - Bowden Cable System Model FQAA The Model FQAA was developed for air balancing at the mid/duct above inaccessible ceilings with Mechanical Push-Pull adjustments at a terminal controller.

More information