829 LED Flashing Beacon

Size: px
Start display at page:

Download "829 LED Flashing Beacon"

Transcription

1 829 LED Flashing Beacon Long-Life LED flashing beacon Shock-proof and vibration resistant mounting solution suitable for Ø 25 mm and 1/2 NPT tubes Life duration up to 50,000 hrs Fiing: Weight: 200 g 235 g Operating Voltage: 24 V, 115 V, 230 V Current consumption: < 30 ma Flash frequency: Life duration up to 50,000 hrs Voltage 24 V 115 V 230 V red yellow clear Voltage 24 V 115 V 230 V red yellow clear LED flash enables use in safety relevant applications or with batteries/ power packs IP65 125

2 829 LED Permanent/Blinking Beacon Multi-functional LED beacon Interchangeable light effects Life duration up to 50,000 hrs mounting solution suitable for Ø 25 mm and 1/2 NPT tubes High protection rating IP 65 Fiing: Weight: 200 g 235 g LED PERMANENT/BLINKING BEACON INTERCHANGEABLE LIGHT EFFECT Blink frequency: Operating Voltage: 24 V Current consumption: 150 ma Life duration up to 50,000 hrs LED PERMANENT BEACON Operating Voltage: 115 V 230 V Current consumption: 30 ma 30 ma LED PERMANENT/BLINKING BEACON Fiing Voltage 24 V 24 V red green yellow blue LED PERMANENT BEACON Fiing Voltage 115 V 230 V 115 V 230 V red green yellow blue X X g 220 g IP65 126

3 829 LED Permanent/Blinking/Rotating Beacon with eternal triggering Multi-functional LED beacon 3 light effects can be remotely selected Electrically isolated signal inputs Positive and negative logic possible mounting solution suitable for Ø 25 mm and 1/2 NPT tubes Fiing: Weight: 220 g 255 g Blink frequency: Rotating frequency: c. 180 r.p.m. Current consumption: 300 ma Bracket (accessories) Fiing Voltage 24 V 24 V red green yellow blue with eternal triggering Light effects set via control cables ADDITIONAL INFORMATION: 24 Vca + 24 Vca + SPS /Déclenchement X4 X5 X1 X2 X3 +24 Vca COM 2 Contrôle 829 LEDs Feu fie Feu clignotant Feu rotatif Thanks to the eternal trigger function, the range of light effects offered by the LED Beacon 829 can be set by means of electricially isolated, binary coded 24 V control cables. This guarantees a much greater level of resistance to electrical interference. The machine operator can use the different signals to indicate various machine conditions without having to make adjustments to the beacon itself. In addition the LED beacon 829 can be used in conjunction with both positive and negative trigger logic. Three different light effects with one device 220 g IP65 127

4 Technical Diagrams 826/827/828/829 Permanent/Blinking/Flashing/ LED Beacon () 826/827/828/829 Permanent/Blinking/Flashing/ LED Beacon () 28 Suitable for 1/2 NPT or Ø 25 mm tubes ø ø Technical Diagrams 138,5 28, X10 55 ø 74 ø X70 55 ca (+) (-) B 1 B 2 A 1 A 2 24V = < 30V = < 100 ma R on < 25 Ohm 828 X f1 + f 2 23,5 (0,5Hz)(1,5Hz) V- V+ SPS / Steuerung 829 LED 24 V DC + X1 24 V DC + X2 X3 Dauerlicht Blinklicht Rundumlicht +24 V DC X4 X5 Control COM 2 285

5 Technical Diagrams 826/827/828/829 Accessories ø 21,9 ø 10,5 ø ,5 1.5 Rubber seal Ø R 3 ø Wire guard 98,5 ±0,3 ø ±0,3 10,4 44,2 ±0, , ±0, ø 12, Base for tube, plastic 830 Flashing Beacon ø 5,2 ø 108 ø Technical Diagrams Accessories Bracket 110 ø 5,2 ø ø Bracket 12 14,5 286

Optical Signal Devices

Optical Signal Devices NEW Page 116 Page 131 Page 128 Page 106 and 110 NEW Page 134 NEW Page 142 Page 120 Overview Page 114 Page 108 and 112 Page 138 Further information about Optical Signal Devices can be found in the chapter

More information

Signal Tower K 70 Signal Beacons K SB. New in the ABB Pilot devices assortment

Signal Tower K 70 Signal Beacons K SB. New in the ABB Pilot devices assortment Signal Tower K 70 Signal Beacons K SB New in the ABB Pilot devices assortment New in the ABB Pilot devices assortment Signal Tower K 70 - Fast mounting of signal elements using bayonet fixing - Easy changing

More information

Installation Instructions for LED Timing Light

Installation Instructions for LED Timing Light Daytona Sensors LLC Engine Controls and Instrumentation Systems Installation Instructions for CAUTION: CAREFULLY READ INSTRUCTIONS BEFORE PROCEEDING OVERVIEW The P/N 120001 includes a versatile controller

More information

POWER SUPPLY aps-412_en 06/16

POWER SUPPLY aps-412_en 06/16 APS-412 POWER SUPPLY aps-412_en 06/16 The APS-412 switching power supply has been designed for use with 12 V DC electrical devices. It comes with a dedicated connector allowing for integration with Satel's

More information

Figure 1: WPR2 Dimensions and Hardware

Figure 1: WPR2 Dimensions and Hardware Installation and Operation Instructions WPR2 Series (Max. Line Pressure < 300 PSI) Wet to Wet Differential Pressure Ø0.200" 2.60" 4.47" 5.47" 5.28" 3.00" Precautions Figure 1: WPR2 Dimensions and Hardware

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled PRO EZ-3, 4 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with LI interface and automatic test function For self-contained emergency lighting SELV for output

More information

B-PC20 Power Close Module

B-PC20 Power Close Module B-PC20 Power Close Module Instruction Manual Document number: B-PC20-C Release: V1.2 Date: OCT 12,2011 ! WARNING This control must be adjusted/serviced by a qualified person. The service technician must

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with I interface and automatic test function For self-contained emergency lighting

More information

Multiple Lever Types. Proximity Limit Switch. Circuitry. The Proximity Limit Switch utilises magnetic switching to sense and trigger off ferrous

Multiple Lever Types. Proximity Limit Switch. Circuitry. The Proximity Limit Switch utilises magnetic switching to sense and trigger off ferrous Proximity Limit Switch The Proximity Limit Switch utilises magnetic switching to sense and trigger off ferrous metals. All components are sealed and protected within the rugged brass housing eliminating

More information

Marine Exhaust Temperature Alarm. COMPONENTS

Marine Exhaust Temperature Alarm. COMPONENTS Marine Exhaust Temperature Alarm. Model: SM0012 INTRODUCTION COMPONENTS Marine water cooled exhaust systems are designed to withstand temperatures of up to about 120 C. However the exhaust gases from the

More information

ICS Switch Panel. Introducing the new

ICS Switch Panel. Introducing the new Introducing the new ICS Switch Panel New vehicles have proven to be increasingly difficult when it comes to installing electrical accessories, including finding a location to place the required number

More information

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Motor cable length 0.3 m. T [mm]

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Motor cable length 0.3 m. T [mm] ACME SCREW LINEAR ACTUATOR ATL 02 Stroke Actuator with DC motor La =Lc + Stroke Lc T OVERALL DIMENSIONS Rear bracket SP Pin Actuator with or 3-phase motor Capacitor Stroke end reed switches FCM Motor cable

More information

PRECISION MOTION CONTROL

PRECISION MOTION CONTROL PRECISION MOTION CONTROL P535 - series s The P535 series provides a combination of optimum size and price for use in instrumentation applications that require digital control of position and speed. Features

More information

ACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor

ACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor ACME SCREW LINEAR ACTUATOR ATL 10 AC motor Stroke OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor Rear bracket SP Pin Standard head with threaded hollow bore 80 BA depth 17 Stroke end reed switches FCM

More information

3-36. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Guard Locking Switches 440G-MT

3-36. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Guard Locking Switches 440G-MT Safety Guard Locking 440G-MT General 1-2-Opto-electronics 3-Interlock Logic Description The 440G-MT solenoid switch is a positive mode, tongue operated guard locking interlock switch that locks a machine

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE

More information

APPLICATION NOTES. Industrial Wall Control (IWC10) (English) (IWC10)

APPLICATION NOTES. Industrial Wall Control (IWC10) (English) (IWC10) APPLICATION NOTES Industrial Wall Control (IWC0) (English) (IWC0) The Breezair Industrial Wall Control (IWC0) is designed to provide both local and external Evaporative Air cooler control for all Breezair

More information

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series EM converter EM converter PRO 200 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series PRO 50 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power SEFTEST 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with self-test function For self-contained emergency lighting SEV for output voltage

More information

Model 2000 Installation Guide

Model 2000 Installation Guide Model 2000 Installation Guide 2001 Directed Electronics, Inc. Vista, CA N2000 8-01 Rev. N/C 1.0 table of contents What Is Included..................... 2 Primary Harness (H1), 12-Pin Connector..... 3 Door

More information

Data Sheet. AmLok.

Data Sheet. AmLok. Data Sheet AmLok options: amgard safety gate switch solutions consist of a range of Control interlocks. The control Interlocks are split into gate switches (Stops) and solenoid Interlocks (Loks). Combining

More information

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual Elite Power Solutions Automatic Battery Control (ABC) Operation Manual Elite Power Solutions 335 E Warner Rd. STE 3 Chandler, AZ 85225 www.elitepowersolutions.com ABC Operation Manual Page 1 Table of Contents

More information

Emergency lighting units EM powerled. EM powerled BASIC 4W Emergency lighting LED Driver

Emergency lighting units EM powerled. EM powerled BASIC 4W Emergency lighting LED Driver BASIC 4W Emergency lighting Driver Product description Emergency lighting Driver for manual testing For self-contained emergency lighting SEV for output voltage < 60 V DC ow profile casing (21 x 30 mm

More information

S 370 MODULAR STACK LIGHTS FEATURES. Multifunctional Lamp. 1 lamp, 3 different kinds of lights. Steady, flashing and rotating.

S 370 MODULAR STACK LIGHTS FEATURES. Multifunctional Lamp. 1 lamp, 3 different kinds of lights. Steady, flashing and rotating. MODULAR STACK LIGHTS S 370 FEATURES Multifunctional Lamp An easy and functional accessory. Simplifies the un-mounting of the stack light Remount fast and flawlessly Light lamp 1 lamp, 3 different kinds

More information

10 Ch Peak & Hold Injector Driver PN

10 Ch Peak & Hold Injector Driver PN Installation Instructions 10 Ch Peak & Hold Injector Driver PN 30-2710 WARNING: installation is not for the electrically challenged! Use this product with extreme caution! If you are uncomfortable with

More information

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters FEATURES...5 to...5 bar,...5 to...5 psi gage 1 For corrosive media in harsh environments 1...6 or... ma output Field interchangeable All welded stainless steel diaphragm construction MEDIA COMPATIBILITY

More information

USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No.

USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No. User Manual ZSP100 Document No. 0658.00.95-03.2 Page 1/6 MERAWEX Sp. z o.o. Toruńska 8 44-122 Gliwice Poland tel. +48 32 23 99 400 fax +48 32 23 99 409 merawex@merawex.com.pl http://www.merawex.com.pl

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power BASIC 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing For self-contained emergency lighting SEV for output voltage < 60

More information

Switches Unlimited Contact: Phone: * Fax:

Switches Unlimited Contact: Phone: * Fax: Phone: 00-221-047 * Fax: 71-672-6370 Page -2 Page -3 SIGNAL TOWERS Signal towers Ø70mm Steady, blinking light or flash modules Pulsed or continuous sound modules Incandescent and LED bulbs. SIGNAL BEACONS

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power SEFTEST 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with self-test function For self-contained emergency lighting SEV for output voltage

More information

Steering column and sensor

Steering column and sensor Steering column and sensor Type LAB Series 1 x Nominal voltage 12 to 48 volt Output signal digital, analog and direction (option) HE 11874 / 09.2017 2 LAB HE 11874 / 09.2017 Page Content 4 4 5 6 7 7 8

More information

I. Introduction - basic information 3 II. Installation into a vehicle 3. III. Attachments 9

I. Introduction - basic information 3 II. Installation into a vehicle 3. III. Attachments 9 ampire FLEET200 Contents I. Introduction - basic information 3 II. Installation into a vehicle 3 1. Placement of the unit 3 2. Connecting the wiring harness 4 2.1 Input - IGNITION 6 2.2 Input BUSINESS

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Power Supply

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Power Supply Safety Guard Locking Atlas 5 General 1-2-Opto-electronics 3-Interlock Logic Description The Atlas 5 is a positive-mode, tongue-operated guard-locking interlock switch that locks a machine guard closed

More information

PO Box 2484 Rowville Vic 3178

PO Box 2484 Rowville Vic 3178 www.solar4rvs.com.au info@solar4rvs.com.au 0488 918 910 PO Box 2484 Rowville Vic 3178 1. Primary Functions and Features The Controller provides three primary functions: 1. The Maximum Power Point Tracking

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Emergency lighting units Product description emergency lighting supply unit with I interface and automatic test function Properties Mains and emergency operation I interface

More information

Model K20 installation guide. ProSecurity

Model K20 installation guide. ProSecurity Model K20 installation guide ProSecurity NOTE: This product is intended for installation by a professional installer only! Any attempt to install this product by any person other than a trained professional

More information

Operating Instructions. Angle Seat Control Valve. Type 7020

Operating Instructions. Angle Seat Control Valve. Type 7020 Operating Instructions Angle Seat Control Valve Type 7020 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 02/2006 Manual-7020e.doc Art.-No:

More information

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series ST 90 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC

More information

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series ST 50 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow

More information

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range Silvertel V1.1 October 2012 Pb 1 Features Multi-Stage Charging Battery Reversal Protection Reduced Power Consumption Wide DC or AC Input Voltage Range High Efficiency DC-DC Converter Programmable Charge

More information

Emergency lighting units EM series

Emergency lighting units EM series EM power PRO EZ-3 Emergency lighting supply units Product description emergency lighting supply unit with DALI interface and automatic test function Properties Mains and emergency operation DALI interface

More information

INSTALLATION GUIDE Multi-Gauge Set with sending units Part Number: M 9999

INSTALLATION GUIDE Multi-Gauge Set with sending units Part Number: M 9999 Made in America Lifetime Guarantee Thank you for purchasing this instrument set from Intellitronix. We value our customers! INSTALLATION GUIDE Multi-Gauge Set with sending units Part Number: M 9999 * Always

More information

General_technical_data Series

General_technical_data Series Indicator Lens Actuator Cable 2-poles with plug-in connection 2.8 x 0.8 mm Flat plug-in housing rectangular, AMP No. 626 057-0 Receptacle housing AMP No. 626 0-0 Receptacle socket AMP No. 160 655-2 Wire

More information

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Actuator with. Attachment A1. Lc [mm] Stroke Stroke T [mm] Stroke Stroke

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Actuator with. Attachment A1. Lc [mm] Stroke Stroke T [mm] Stroke Stroke ACME SCREW LINEAR ACTUATOR CLA 20 OVERALL DIMENSIONS Stroke La =Lc + Stroke Lc T La =Lc + Stroke Lc T Rear bracket SP Pin FC switches and potentiometer Attachment A1 Attachment A2 Motor cable length 0.3

More information

Specification subject to change without notice! All rights reserved page 1 of 5

Specification subject to change without notice! All rights reserved page 1 of 5 Electro Hydraulic Servo Valve Single Stage Hydraulic Symbol Introduction: The HVM 068 is a single stage servo valve in spool and sleeve construction. It is designed special for low pressure applications

More information

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V DSOS24V v.1.0 FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V EN* Edition: 2 from 30.08.2017 Supercedes edition: 1 from 24.05.2016 PSU features. Compliant with the requirements of the

More information

Enclosure and Panel Solutions. View Industrial Products Brochure

Enclosure and Panel Solutions. View Industrial Products Brochure View Industrial Products Brochure 54 55 Cable Glands, Cord Grips, Strain Relief Fittings Nylon Cable Glands Material: Polyamide PA6.6 Temp Range: -20 C to +90 C Sealing Ring: Neoprene 50 sh A Protection

More information

Safety Edge HSC HSC T. Technical data. Intended use. Function

Safety Edge HSC HSC T. Technical data. Intended use. Function HSC 65-35-01 T 12 Intended use 35 39 ±2 65 +4 All dimensions in mm Safety Edges are used for protecting against risks at Enclosure sealing: shearing and crushing edges, for instance at machine guards,

More information

SERIE 59S. Rear clamp. Frontal clamp INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS SIN/COS

SERIE 59S. Rear clamp. Frontal clamp INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS SIN/COS INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS Resolution up to 2.048 pulses per turn Shaft fixing through front or rear clamp External diameter 58 mm Hollow shaft Ø 10, 12 or 14 mm Protection

More information

2005 Directed Electronics, Inc. Vista, CA N412V 01-05

2005 Directed Electronics, Inc. Vista, CA N412V 01-05 Model 211HV Installation Guide NOTE: This product is intended for installation by a professional installer only! Any attempt to install this product by any person other than a trained professional may

More information

Installation Instructions - K-Safe-T-Rip Belt Rip Detector

Installation Instructions - K-Safe-T-Rip Belt Rip Detector Kinder Australia product: Preferred Setup Instructions Note: The correct Belt Rip pick up detachment operation of the Rip Socket, is in a sideways motion to the attachment point. This means once the Socket

More information

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007) Installation, Operation and Maintenance Manual (from February 2007) Publication 2698C (GB) 0207 1A 3319 8035B Donaldson reserve the right to alter design without notice. Freedom from patent restrictions

More information

Electronic Controls Proportional Valve Control Power Plugs

Electronic Controls Proportional Valve Control Power Plugs Electronic ontrols Proportional Valve ontrol Power Plugs EHH-AMP-70-D/J/K-* Series For use with valve types: EPV**-D-* EFV-**-0DE* ERV/**-D-* EPRV**-D-* Application Primary applications are in the control

More information

Ultrasonic Sensor U-B

Ultrasonic Sensor U-B MAINTAIN CONSTANT TENSION - The ultrasonic sensor is used to maintain constant tension when using a brake for producing unwind (payout) tension, or when using a clutch for rewind tension. The sensor measures

More information

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview Product Description The MediaGauge MG-MD is a multi-functional digital pressure gauge consisting of a media isolated piezoresistive pressure sensing element, signal conditioning circuitry for temperature

More information

CTE7000 / CTU7000 Series Miniature pressure transmitters

CTE7000 / CTU7000 Series Miniature pressure transmitters FEATURES 10 mbar to bar, 0.1 to 7 psi gage 1 pressure 0..., 0...10, 0...4., 1...6 or 4...20 ma output Field interchangeable Rugged stainless steel housing EMC according to EN 61326-1 9 MEDIA COMPATIBILITY

More information

Solenoid interlock AZM 200 The non-contact interlock.

Solenoid interlock AZM 200 The non-contact interlock. Solenoid interlock AZM 200 The non-contact interlock. Solenoid interlock AZM 200 The non-contact Solenoid interlocks demand accurate alignment of actuator and device. This requirement is met on new machinery.

More information

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media FEATURES mbar to 35 bar, 15 to 500 psi gage 1 or absolute 10 pressure 05, 010, 0545, 16 or 420 ma output Field interchangeable All welded stainless steel diaphragm construction EMC according to EN 61326-1

More information

ELECTRIC ACTUATORS 400 N

ELECTRIC ACTUATORS 400 N ELECTRIC CTUTORS 400 N SE4 PPLICTION Electric actuator SE4 is suitable to drive valve body series in HVC systems. Two action types are available: - floating (3-point) - modulating Vdc and m. ctuator is

More information

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S Product Manual ABB i-bus EIB EIB Power Supply Units SV/S 30.320.5 SV/S 30.640.5 SU/S 30.640. Intelligent Installation Systems Contents Page EIB Power Supply Units. Introduction.........................................

More information

INSTALLATION SHEET MODEL 618 SHEET NO ISSUE 2. The 618 can be mounted on the car doors using the standard fixing kit provided (Fig 1).

INSTALLATION SHEET MODEL 618 SHEET NO ISSUE 2. The 618 can be mounted on the car doors using the standard fixing kit provided (Fig 1). Memco Elite INSTALLATION SHEET MODEL 618 SHEET NO. 618 850 ISSUE 2 SYSTEM DESCRIPTION The 618 safety system consists of a transmitter detector (TX) and a receiver detector (RX) mounted on, or beside, the

More information

CLA 25 AC motor ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Rear bracket SP. Stroke. Capacitor. Standard head with threaded hollow bore BA

CLA 25 AC motor ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Rear bracket SP. Stroke. Capacitor. Standard head with threaded hollow bore BA ACME SCREW LINEAR ACUAOR CLA 5 AC motor OVERALL DIMENSIONS Stroke La = + Stroke Capacitor La = + Stroke Rear bracket SP Pin Standard head with threaded hollow bore BA 1 Attachment A1 Attachment A depth

More information

OEM Pressure Transmitters

OEM Pressure Transmitters OEM Pressure Transmitters Type MH-2 Applications Mobile hydraulic systems Automotive industry Compressor systems Special Features Pressure ranges from 1000 psi to 8000 psi 4-20 ma, 1-5V, 0-10V, 0.5-4.5V

More information

TRANSFORMER RECTIFIER

TRANSFORMER RECTIFIER TRANSFORMER RECTIFIER voltage from the commercial electrical power grid or an engine-generator. A transformer with tap adjustments in the secondary side provides a method to reduce and adjust the output

More information

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces: Electronic pressure switch Type HEDE 10 RE 30277 Edition: 2017-02 Replaces: 2016-06 Component series 3X Maximum operating pressure 600 bar Features Suitable for measuring pressures in hydraulic systems

More information

Dimmer Switches. Product Range. Dimmer Switches For Tungsten, Halogen & Low Voltage. Facsimile: Website:

Dimmer Switches. Product Range. Dimmer Switches For Tungsten, Halogen & Low Voltage. Facsimile: Website: Dimmer Switches The smooth modern lines of the Polar accessory plate will fit easily into traditional and contemporary designs alike. Polar dimmer switches are developed largely for use with Tungsten,

More information

ASI. Blinking or Steady Light Modules

ASI. Blinking or Steady Light Modules Signal beacons Ø6mm / Ø.44 Steady light modules. BA5d fitting. Bulb not included. LB6 EL Orange 0.060 LB6 EL3 Green 0.060 LB6 EL4 Red 0.060 LB6 EL5 Yellow 0.060 LB6 EL6 Blu 0.060 LB6 EL White 0.060 Blinking

More information

INSTRUMENTATION & CONTROL

INSTRUMENTATION & CONTROL Irrigation Controller.................... 172 Window Controller.................... 174 Water Meter Controller.................. 176 Digital Level Switch.................... 177 Filtration Controller Set..................

More information

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS BSA 10 AC motor Stroke La =Lc + Stroke Lc Capacitor T Rear bracket SP Pin Standard head with threaded hollow bore BA 80 depth 17 Stroke end reed switches FCM

More information

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor ACME SCREW LINEAR ACTUATOR Stroke OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor Rear bracket SP Pin Standard head with threaded hollow bore BA depth 17 Stroke end reed switches FCM Lenght Stroke 300

More information

SIGNAL BEACONS Signal beacons Ø62mm Blinking or steady light modules Sound-light pulsed or continuous modules Incandescent and LED bulbs.

SIGNAL BEACONS Signal beacons Ø62mm Blinking or steady light modules Sound-light pulsed or continuous modules Incandescent and LED bulbs. Page -2 Page -3 SIGNAL TOWERS Signal towers Ø70mm Steady, blinking light or flash modules Pulsed or continuous sound modules Incandescent and LED bulbs. SIGNAL BEACONS Signal beacons Ø62mm Blinking or

More information

RI360P0-QR24M0- INCRX2-H1181 Contactless Encoder Incremental

RI360P0-QR24M0- INCRX2-H1181 Contactless Encoder Incremental RI360P0-QR24M0- INCRX2-H1181 Contactless Encoder Incremental Features Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per

More information

ACME SCREW LINEAR ACTUATOR. Current [A] PERFORMANCES with AC 3-phase 50 Hz 230/400 V or 1-phase 50 Hz 230 V motor

ACME SCREW LINEAR ACTUATOR. Current [A] PERFORMANCES with AC 3-phase 50 Hz 230/400 V or 1-phase 50 Hz 230 V motor ACME SCREW LINEAR ACTUATOR CLA 28 OVERALL DIMENSIONS La = Lc + Stroke Stroke Lc T Standard head with threaded hollow bore BA Motor cable length 0.3 m Bronze bushes depth 17 Lc [mm] T [mm] Length [mm] +

More information

CENTRIFLOW METER and ELECTRONICS WIRING and INSTALLATION MANUAL REV 01/16 ORIGINAL LANGUAGE Copyright 2016 Eastern Instrument Laboratories, Inc. All Rights Reserved. TABLE OF CONTENTS SAFETY Safe Operation...

More information

INDUCTIVE SENSORS FOR UTILITY VEHICLES. Sense it! Connect it! Bus it! Solve it!

INDUCTIVE SENSORS FOR UTILITY VEHICLES. Sense it! Connect it! Bus it! Solve it! INDUCTIVE SENSORS FOR UTILITY VEHICLES Sense it! Connect it! Bus it! Solve it! MOUNTING ACCESSORIES BSS-12 Dimensions/Types/Ident no./short description BSS-18 BSS- ø 12 34 2, 901321 Mounting accessories

More information

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve. AP64E00DX00X Characteristics to VDI 90 Pressures quoted as gauge pressure Characteristics Symbol Unit Description General Features Spool valve Mounting screws M Tube connection Thread Port size ; 7.4 deep

More information

Page 8-3. MULTICOLOURED SIGNAL TOWERS Ø70mm/2.75. Modular signal towers Ø70mm/2.75

Page 8-3. MULTICOLOURED SIGNAL TOWERS Ø70mm/2.75. Modular signal towers Ø70mm/2.75 Page -2 SIGNAL TOWERS Ø45mm/1.77 Signal towers supplied already assembled Ø45mm/1.77 Steady light modules Pulsed or continuous sound modules Built-in LED circuit. Page -3 MULTICOLOURED SIGNAL TOWERS Ø70mm/2.75

More information

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer,

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer, Phocos CML-V2 Solar charge controller User Manual (English) Dear customer, Thank you very much for buying this Phocos product. Please read the instructions carefully and thoroughly before using the product.

More information

Type I/P & E/P Transducers

Type I/P & E/P Transducers Type 1500 I/P & E/P Transducers Type 1500 Description The T-1500 is a new series of electro-pneumatic transducers that convert an electrical signal to a proportional pressure output. It provides precision

More information

Your new LM controller is a state-of-the art device which was developed in accordance with the latest

Your new LM controller is a state-of-the art device which was developed in accordance with the latest CAP LM-series Solar charge controller User Manual Thank you very much for buying this CAP product. Please read the instructions carefully and thoroughly before using the products. Your new LM controller

More information

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version T5 T8 TC- TC-F DE TC- TC-SE TC-TE TC-DD T5c EM SEFTE, 220 240 V SEFTEST version Product description Emergency lighting supply unit with self-test function For linear and compact fluorescent lamps ow-profile

More information

CORNERING LIGHTING MODULE CLM02-CAN INSTALLATION MANUAL

CORNERING LIGHTING MODULE CLM02-CAN INSTALLATION MANUAL CORNERING LIGHTING MODULE CLM02-CAN INSTALLATION MANUAL QUASAR ELECTRONICS ul. Cieślewskich 2K 03-07 Warszawa tel. (22) 427-3-4..44 http://www.quasarelectronics.pl e-mail: biuro@quasarelectronics.pl OPERATION

More information

SP5 INSTALLATION AND SETUP MANUAL

SP5 INSTALLATION AND SETUP MANUAL SP5 INSTALLATION AND SETUP MANUAL 1 Installation 1.1 Introduction The SP5 System consists of a Data Acquisition unit (DAQ) with two complete Roller control channels, each Roller Control Channel consists

More information

Signal towers and beacons

Signal towers and beacons Signal towers 5mm/1.77 Supplied already assembled Steady light and pulsed or continuous sound modules Multicoloured signal towers Ø70mm/2.75 Modular and combinations up to 5 modules Steady light and pulsed

More information

JUMO MIDAS S05 Pressure transmitter Type

JUMO MIDAS S05 Pressure transmitter Type Data Sheet 40.00 Page /8 JUMO MIDAS S05 Pressure transmitter Type 4000 Brief description The JUMO MIDAS S05 pressure transmitter is available with both relative pressure and absolute pressure measurement

More information

Emergency lighting units EM INVERTER

Emergency lighting units EM INVERTER T T8 TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM, 0 40 V 0/0 Hz PRO version Product description Emergency lighting supply unit with DAI interface and automatic test function For linear and compact fluorescent

More information

Emergency lighting units PC COMBO

Emergency lighting units PC COMBO TC-DD PC CFL E COMBO, 230 240 V 50/60 Hz Compact fluorescent lamps Product description Combination of electronic ballast and emergency lighting unit For TC-DD compact fluorescent lamps For manual testing

More information

Signaling solutions. Monolithic indicator banks Harmony type XVC. Dimensions: page 12

Signaling solutions. Monolithic indicator banks Harmony type XVC. Dimensions: page 12 Presentation Presentation The monolithic indicator banks in the Harmony XVC range are designed for long distance indication of the operating states or sequences of a machine or installation, either visually

More information

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION... Table of Contents 1. OVERVIEW... 2 2. OPERATION FUNCTION... 2 3. SPECIFICATIONS... 3 4. INSTRUM LAYOUT... 4 4.1 OPERATION KEY...4 4.2 INDICATORS...4 5. INSTALLATION... 5 5.1. ENVIRONM CONDITIONS...5 5.2

More information

Operating instructions Binary level sensor LMT /00 06/2011

Operating instructions Binary level sensor LMT /00 06/2011 Operating instructions Binary level sensor LMT UK 706052/00 06/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Application area...4

More information

Dimmer Switches (Modular)

Dimmer Switches (Modular) Dimmer Switches (Modular) The smooth modern lines of the Define accessory plate will fit easily into traditional and contemporary designs alike. Define dimmer switches are developed largely for use with

More information

Air Flow Controller M1compact Type-Summary FKM 130

Air Flow Controller M1compact Type-Summary FKM 130 Air Flow Controller M1compact -Summary FKM 130 One-part sensor for controlling air and gaseous flows with integrated evaluation electronic. The air flow controller is mounted into the flow to be controlled

More information

USER GUIDE 12 V Lead acid batteries Ah

USER GUIDE 12 V Lead acid batteries Ah USER GUIDE 12 V Lead acid batteries 1-150 Ah GB 1 Thank you for choosing this charger from Exide Technologies Your new battery charger will enable you to keep your battery fully charged and will optimize

More information

HOLLEY VR2 FUEL PUMPS P/N & Installation Instructions 199R10975

HOLLEY VR2 FUEL PUMPS P/N & Installation Instructions 199R10975 HOLLEY VR2 FUEL PUMPS P/N 12-3000 & 12-3000-2 Installation Instructions 199R10975 WARNING! THESE INSTRUCTIONS MUST BE READ AND FULLY UNDERSTOOD BEFORE BEGINNING INSTALLATION. FAILURE TO FOLLOW THESE INSTRUCTIONS

More information

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar Pressure Transmitter Type FM40466 General application Pressure transmitters are used to measure the relative (gauge) and absolute pressures in liquids or gases. The measuring device for the transmitter

More information

Dimmer Switches (Modular)

Dimmer Switches (Modular) Dimmer Switches (Modular) The smooth contemporary curves of the Deco Plus range are available in seven finishes to compliment any room. Deco Plus dimmer switches are developed largely for use with Tungsten,

More information

MINI ANTI-INCRUSTATION AND ANTI-CORROSION SYSTEM FOR PIPES AND SEA WATER INTAKES

MINI ANTI-INCRUSTATION AND ANTI-CORROSION SYSTEM FOR PIPES AND SEA WATER INTAKES PROTECCION CATODICA (C.I.) DE PEQUEÑAS EMBARCACIONES S.L. MINI ANTI-INCRUSTATION AND ANTI-CORROSION SYSTEM FOR PIPES AND SEA WATER INTAKES OBJECTIVES: The first objective is to kill the marine organisms

More information

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series Product description Fixed output constant current built-in LED Driver, particularly suitable for industrial applications in tough enviromments such

More information