1 Standards & Preferences Electrical Workshop- Section IX July 14 th, 2016

2 Agenda Welcome Introductions Purpose of Workshop EEM Organizational Structure S&P Section IX Layout Review of Updates Reoccurring Themes Q&A 2

3 Electrical & Energy Management (EEM) Organizational Structure Rick Raike - Chief of Electrical and Energy Management 3

4 Electrical and Energy Management Organizational Chart FY-16 Operations Director Operations Chief of Electrical and Energy Management NS Electrical Manager Electric Shop Instrumentation Manager Electric Shop SS Electrical Manager Electric Shop NS Materials & Ops Coordinator SS Materials & Ops Coordinator NS E & I Supervisor NS E & I Supervisor SS E & I Supervisor Electrical Superintendent CIP Projects SS E & I Supervisor NS E & I (6) NS E & I (7) SS E & I (7) CIP Projects Requiring FTE E & I s (7) SCADA Admin Asst 1 SS E & I (8) SCADA Tech 1 July 2015

5 S&P Section IX Layout Format change from table format to specification format Consist of two sections Pump stations and Treatment Plants Pump Stations consist of 30 items and Treatment Plants consist of 36 items Attachments A~E Grey highlights will indicate latest changes 5

6 Item # Pump Station Item Description Page # 1 Switchgear and MCC 3 2 Emergency Generators 7 3 Energy Efficient Motors 13 4 Sump Pumps 14 5 Level Sensing Systems 14 6 Variable Frequency Drives (VFDs) 15 7 Watt Hour Meter (for MCCs or individual motors) 17 8 PLCs 17 9 Exhaust Fans Lighting Concrete Housekeeping Pads Conduit and Conduit Systems Wire Relays Lockout/Tagout Safety Switches/Receptacles/Plugs Electric Heaters Electrical Drawings Safety Switches (fused or unfused) Transformers Metering Vaults/Pits Pressure Sustaining/Regulating 25 Valves 23 Alarm Systems Flow Meters RTUs Louvers/Dampers Cathodic Protection Junction Boxes and Misc. 28 Enclosures 29 Panel Boards/Control Panels Miscellaneous Electrical 29 Item # 6 Treatment Plant Page # 1 Switchgear 30 2 MCCs 33 3 Emergency Generators 37 4 Energy Efficient Motors 43 5 Sump Pumps 43 6 Level Sensing Systems 43 7 Variable Frequency Drives (VFDs) 46 8 Metering Packages for Switchgear, MCCs or Individual Motors 47 9 PLCs_TP Exhaust Fans Lighting Concrete Housekeeping Pads Conduit and Conduit Systems Wire Relays Lockout/Tagout Safety Switches/Receptacles/Plugs Heaters Electrical Drawings Safety Switches (fused or unfused) Transformers Metering Vaults/Pits Pressure Sustaining/Regulating Valves Flow Meters RTUs Louvers/Dampers Transfer Switches On-Line Vibration Monitors Panel Meters Analyzers/Monitors Miscellaneous Instrumentation Miscellaneous Electrical Heating and Cooling Junction/Pull Boxes and 66 Miscellaneous Enclosures 35 Panel Boards/Control Panels Distributive Control System (DCS) 67

7 Table Format- S&P Electrical Workshop 2016 PUMP STATION Electrical and Instrumentation Requirements Electrical Equipment/Item Manufacturer Specific Criteria Day Tanks Pryco Tramont - UL Listed double wall - Provide with Oberndorfer bronze gear type pump. Pumps with rubber or nitrile impellers will not be accepted - Provide with a low level alarm and light - Size for 2 hour minimum running time - Provide a fuel level indicator on the day tank - Provide a 2 pump system. Each pump shall be capable of pumping 100% fuel oil throughout the entire system. - Provide Not in Auto lamp or other warning device - Use momentary switch for tank fill/test 7

8 Specification format- S&P Electrical Workshop 2016 Day Tanks Manufacturers Pryco Tramont Specific Criteria UL Listed double wall Provide with Oberndorfer bronze gear type pump. All pumps must be mounted on Day Tank. Pumps with rubber or nitrile impellers will not be accepted Provide with a low level alarm and light Size for 2 hour minimum running time Provide a fuel level indicator on the day tank Provide a 2 pump system. Each pump shall be capable of pumping 100% fuel oil throughout the entire system. Provide Not in Auto lamp or other warning device Use momentary switch for tank fill/test 8

9 Day Tank - S&P Electrical Workshop 2016 Day Tanks 1. All pumps must be mounted on the Day Tanks. In ground pumps not preferred, but may used in site specific applications. See pg. IX-11 9

10 E- Stops -Mfr: Pilla -Model: GS120 See pg. IX-40 10

11 Review of Updates (Part 1) 11

12 Generator Section - S&P Electrical Workshop 2016 Review of Updates (Part 1) Generator Section for Pump Stations and Treatment Plants. 1. Size air, fuel, and oil filters to provide a minimum 250 hours before servicing (a minimum of 100 hours was previously stated). See pg. IX-9 & Removed - Mfr. American Battery Charger. See pg. IX-10 & Added - SENS Battery Charger. See pg. IX- 10 & 42 12

13 Generator Section - S&P Electrical Workshop Added - Size radiator to prevent overheating in the most severe conditions; changed from 110 F to 122 F. See pg. IX Added - 4D starting batteries are not acceptable (Use 8D only). See pg. IX-11 & 42 13

14 Variable Frequency Drives (VFD s) 1. Change the name from Power Logix to Power Flex Series (Allen Bradley) See pg. IX- 16 & 49 14

15 Rubber Matting 1. What is considered OSHA approved matting? Electrical rated matting that meets the Type II ASTM D178 Standard. See pg. IX-10, 35, & 39 15

16 Conduits 1. Painted red in pump station per request of the owner (Does not apply for PVC Coated Rigid). Refer to Section X Coatings manual page 148. See pg. IX-21 16

17 MCC/Switchgear Fasteners 1. Provide extra fasteners when ordering gear (spare parts). See pg. IX-33 and IX-36 17

18 Analyzers/Monitors 1. Added E&H probe for Incinerator scrubber water (process ph); Specific applications at Treatment Plants See pg. IX-67 18

19 Level Sensing Systems Bubbler 1. Remove Bell & Gossett as Mfr. 2. Add model 3HBB-10-M300 AX (Dual Head Air Compressor) or equal See pg. IX Separate circuit for each compressor (Panel schedule) 19

20 Voltage Test Points Mfr. Safeside See pg. IX-7 and IX-39 20

21 DIN Rail 1. Add Panduit Panduct DIN Rail Wiring Duct See pg. IX-5 21

22 Review of Updates (Part 2) 22

23 Review of Updates (Part 2) Pump Station section 16- provide one weatherproof (WP/Watertight) receptacle with lockable cover on the exterior wall of the pump station on a separate circuit; separately switched -> must not be hot at all times. See pg. IX-25 Provide high level float ball for alarms See pg. IX-15 Provide Intrinsically safe barriers See pg. IX

24 Add Remote Switch Operator to open/close main circuit breaker outside of the arc flash boundary. See pg. IX-32 24

25 Add ARMS Arms Reduction Maintenance Switch or Equal; When activated downstream incident energy levels will be reduced. See pg. IX-32 25

26 Add LSI or LSIG (>=1000A) Electronic Trip Units See pg. IX-33 26

27 Add Short Circuit, Coordination, and Arc Flash requirements to specifications (Arc Flash calculations must be performed for both Utility bus and Generator bus); A label must be added to the generator breaker. See pg. IX-31 27

28 Push-buttons, selector switches, etc. must be NEMA rated only (Some Mfr. Have both NEMA/IEC ratings on components). See pg. IX-34 & 37 28

29 ETM Add Mfr. Crompton and ENB Elapsed Time Meters; Yokogawa UL certification in question. See pg. IX-65 29

30 Surge Protection Devices Remove SPD Type IC4/IC6 Surge Protectors - Don t use DC powered surge protection on field devices (4~20mA). - Don t use AC powered surge protection for field devices. - All SPD should be installed at the incoming power section of the gear. 30

31 Splicing 1. No splicing allowed on HRSD projects without approval from Engineer/Owner. 2. No splicing in man-holes 3. If granted approval, splicing must be perform by certified splicer. 4. May require above ground installation. 31

32 Variable Frequency Drives- New circuit diagram 32

33 Tegam Windows J. Matt Ferguson DRISCOLL AUTOMATIC 918/ Main 918/ Fax 918/ Cell P.O. Box Tulsa, OK

34 Tegam Windows- AW1012 Can be eliminated if installed in condition spaced. 34

35 Conduit schedule vs. Circuit Method Some consultants method of design does not use conduit schedules so individual conduit tag numbers do not exist. The one line diagrams use circuit numbers. For power circuits (except for lighting and receptacles circuits) a conduit is dedicated to that circuit. For control and instrumentation circuits; They often have multiple circuits in a common conduit. 35

36 Labeling Method (phenolic labels) White lettering on Black background. See pg. IX-30, 33, & 36 36

37 Actuators EIM actuators- verify use of proper voltage 120 vs. 480V -Use proper control boards based upon required voltage. 37

38 Polaris Style Connectors not preferred ; T leads to motor (rarely used); Prefer lugs 38

39 Pump Station ATS Push to test function; manually initiate 2 hour test to start generator and assume load. After two hours the system automatically returns to utility source if available. Note: This is not an exercise function. Remove Mfrs. Cummins and SQD; Specify Eaton or ASCO. See pg. IX-11 39

40 Locate HOA switch at drives for variable speed applications Locate HOA switch at pump for constant speed applications. 40

41 Reoccurring Themes 41

42 Load Bank Test Boxes 1. Fabrication UL Shop Harper Sheet Metal Richmond VA (804)

43 Reoccurring Themes o Load bank test boxes Eaton and other Mfrs. have similar connection boxes; However HRSD standardized the use of Leviton Connectors, due to Operation s wire spool trailers having Leviton mating connectors. o Other products utilize Hubbell connectors. The Mfrs. would like for HRSD to use Hubbell connectors to prevent the modification of their UL listing. 43

44 o Shop Drawing Submittal/Approval Process o HRSD Electrical Staff would desire access to a file storage area, to review submittals in parallel with consultants, in an effort to streamline the overall process. o Secure As-Builts/ Record Drawings before closeout of Project. o Functionals and P&ID s o Interposing Relays o DCU Power Supplies/Isolation transformer o Arc Flash Mitigation (> 40 cal/cm2) Design, SC, Coordination, AF analysis, and labeling. 44

45 o Arc Flash Breaker/Relay settings for contractors. o Variable Frequency Drives (VFD s) o Long term maintenance plan at substantial completion. o Rice Rule o MOPO o Generator/paralleling gear (block load or soft load) 45

46 o 100 ms closed transition test and 225 ms breaker timing test o NFPA 820 o Energy Conservation 46

47 o Dominion Virginia Power Interconnection Agreement 47

48 New Electrical Services 1. Site Plan 2. Load Letter 3. Power Riser 4. Sequence of Operation 5. Access Facility Charges Right size equipment 48

49 49

50 50

51 Lighting Quick strike preferred for metal halide See pg. IX-20 and IX-52 LED preferred 51

52 Wire Stranded wire only (No solid wire allowed). Sometimes solid wire for smaller No. gauge wire will be specified. See pg. IX-23 and IX

53 Some other beneficial practices: Separate Electrical Meetings Checklist for QA/QC Involve HRSD with Electrical Inspections Verify loop checks 53

54 Turnover file, cables, hardware, and software to HRSD. HRSD needs ownership to any processor based controls and/or equipment. No proprietary programs that would not grant HRSD access to modify and/or troubleshoot. 54

55 o Scheduling of Training for Equipment or New systems. o Generator load bank test must witnessed by HRSD EEM and Automotive Representative. o Excavation around live energized lines. Hand dig or pot hole to locate potential utility conflicts. 55

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

ISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD

ISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD ISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD CONTROL PANEL MOUNTING PAGE No. 74 NUMBER: LS-240V1PH-TCU-VFD 35 38 47 U A 9 33 V 26 24 25 41 43 7 7 44 ALUMINUM BACKPLATE 41 42 50 46

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL 13686.00 MECHANICAL AND ELECTRICAL COORDINATION 230002-1 SECTION 230002 MECHANICAL AND ELECTRICAL COORDINATION 1.1 WORK INCLUDED PART 1 - GENERAL A. Work Included in This Section: Materials, equipment,

More information

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein. 16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to

More information

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION! PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling

More information

Ice Rink Renovation & New Clubhouse

Ice Rink Renovation & New Clubhouse SECTION 262913 - ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types: SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification

More information

Existing 400A Circuit Breaker For B Secondary Chill Water Pump. Existing Single 2.5 Conduit. Reuse As Much As Practical

Existing 400A Circuit Breaker For B Secondary Chill Water Pump. Existing Single 2.5 Conduit. Reuse As Much As Practical New A Secondary Chill / 60V /36A Fused Disconnect For A Secondary Chill and Flex New B Secondary Chill / 60V / 36A B Secondary Chill Single 2.5 Conduit. Install New Additional 2.5 R.S.G. Conduit From 00A

More information

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL SECTION 23 04 10 ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 24 14 600 VOLT DRAWOUT SWITCHGEAR PART 1 - GENERAL 1.01 SECTION INCLUDES: A. Individually mounted rear-accessible low voltage switchgear ANSI rated switchgear and low voltage power circuit breakers

More information

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference

2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference 2010 / PM CM 21st Annual Conference The High-Velocity Edge: Achieving Operational Excellence ELECTRICAL / PM CM 2010 Conference Basic Electrical Rick Miller, PE, LEED AP RNM Engineering, Inc. Vanir Corp.

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES Description JRS arc-resistant fused/non-fused load break and fused/non-fused disconnect switches are available for applications

More information

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems www.switchgearpower.com Generator Controls, Paralleling Switchgear, LV Switchboards States Mfg. www.statesmfg.com Transformers (Substation

More information

OEB's Appendix 2-B: Fixed Asset Continuity Schedule

OEB's Appendix 2-B: Fixed Asset Continuity Schedule Page 1 of 11 OEB's Appendix 2-B: Fixed Asset Continuity Schedule Table 1: Fixed Asset Continuity Schedule - Actuals 2008 N/A 1805 Land NA 2.2 - (0.0) 2.2 0 - - - - 2.2 CEC 1806 Land Rights 2.0% 1.6 0.1-1.7

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems. Issued 2005/06/01 Section 15440 Plumbing Pumps Page 1 of 9 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3 Section 01780 Closeout

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton Advances in technology to address safety Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton 1 Advances in technology could mean use existing technology & back to basics Advances in safety are

More information

Three-Phase Pole Mounted Recloser

Three-Phase Pole Mounted Recloser Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE

More information

Appendix C. Interval Every 2 Year. Functional Test Weekly Monthly Quarterly. Semi. Every 3. Engineering Studies

Appendix C. Interval Every 2 Year. Functional Test Weekly Monthly Quarterly. Semi. Every 3. Engineering Studies Engineering Studies Coordination Study Every 5 years and in conjunction with electrical system modifications. Short Circuit Study NETA MTS 6.2 Every 5 years and in conjunction with electrical system modifications.

More information

Transfer switch OTEC and OTECSE open transition

Transfer switch OTEC and OTECSE open transition Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They

More information

STANDBY EMERGENCY CNG/LPG GENERATOR

STANDBY EMERGENCY CNG/LPG GENERATOR SECTION 16620 STANDBY EMERGENCY CNG/LPG GENERATOR PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Compressed natural gas (CNG) or liquefied petroleum gas (LPG) powered standby emergency generators. B.

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Optimizing Emergency Power Systems for Health Care Applications

Optimizing Emergency Power Systems for Health Care Applications 2018 Annual Conference Optimizing Emergency Power Systems for Health Care Applications aka: Using the latest code changes to improve system reliability and maybe even save some $$$... Overview Michigan

More information

SECTION ENCLOSED CONTROLLERS

SECTION ENCLOSED CONTROLLERS SECTION 16420 ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018

Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018 Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018 Outlined below are the engineering documents and their associated minimum detail requirements for a Distributed Energy Resource (DER)

More information

Company Switch Installation Instructions and User Manual

Company Switch Installation Instructions and User Manual Lex Products Corporation 15 Progress Drive Shelton, CT 06484 203.363.3738 203.363.3742 Fax Lex West 11847 Sheldon Street Sun Valley, CA 91352 818.768.4474 818.768.4040 Fax www.lexproducts.com info@lexproducts.com

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

East Central College

East Central College SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Wall switches. b. Receptacles c. Device plates and decorative box covers. 1.2 RELATED

More information

MEDIUM-VOLTAGE SWITCHGEAR

MEDIUM-VOLTAGE SWITCHGEAR REVISION RECORD SECTION 16341 Medium-Voltage Switchgear REV DATE PAGE PARA NO. DESCRIPTION APPROVED BY 28SEP01 ALL Initial issue. 1 29SEP03 ALL General update with miscellaneous changes in entire document.

More information

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan. 57 574 4 574 573 57 57 57 57 1 571 47 474 4 474 473 47 47 47 47 1 471 56 567 7 565 565 37 374 74 374 7 373 37 37 37 37 1 371 467 6 467 465 465 7 74 4 74 73 7 7 7 7 7 71 71 36 367 7 365 365 6 67 7 65 65

More information

ETAP Implementation of Mersen s Medium Voltage Controllable Fuse to Mitigate Arc Flash Incident Energy

ETAP Implementation of Mersen s Medium Voltage Controllable Fuse to Mitigate Arc Flash Incident Energy ETAP Implementation of Mersen s Medium Voltage Controllable Fuse to Mitigate Arc Flash Incident Energy ETAP 17 Goodyear, Suite 100 Irvine, CA 92618 White Paper No.001.14-2016 Albert Marroquin, PE Member

More information

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H) 2101 Commonwealth Blvd, Suite B Ann Arbor, MI 48105-5759 www.med.umich.edu/facilities/plan/ 263010-H: SUPPLEMENTAL PARALLELING GEAR (16315-H) Related Sections Basis Guideline: N/A For an explanation of

More information

Pump Installation and Service Manual HRS Hydromatic Retractable System

Pump Installation and Service Manual HRS Hydromatic Retractable System Pump Installation and Service Manual HRS Hydromatic Retractable System NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party

More information

B BASIC HEAT TREATMENT CONSOLE

B BASIC HEAT TREATMENT CONSOLE Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Change History Date Description of Change Pages / Sections Modified 8/1/17 Updated section for System Design and Performance Requirements and Manufacturers 5>6 C. 4.c..&d.; m; remove p. 8 F. Change Approver

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual For Use with: SNS4, SNS6, SNS10 & SNS15 Models Additional supplements may be needed for

More information

Outdoor Power Transmission & Distribution

Outdoor Power Transmission & Distribution Description: The purpose of the section is to highlight the current applicable UMCP Design Standards and requirements for Outdoor Power Transmission and Distribution, including but not limited to the following:

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

BGE STRATEGIC CUSTOMER ENGINEERING

BGE STRATEGIC CUSTOMER ENGINEERING TABLE OF CONTENTS 1. GENERAL.. 2 2. BGE SUPPLY FEEDER.. 4 3. SWITCHGEAR ENCLOSURE AND ASSEMBLY... 5 4. SWITCHGEAR MANUFACTURERS.. 8 5. CIRCUIT BREAKER.. 8 6. SWITCHGEAR EQUIPMENT.... 10 7. MAIN AND GROUND

More information

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS SECTION 22 11 23.13 (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Packaged Domestic Water Booster Pumps B. Related Sections: 1.02 REFERENCES 1. Section

More information

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5 Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Building Operations Electrical Technical Support.2 UBC Energy & Water Services 2.0 REQUIREMENTS FOR COMMISSIONING AND TESTING 2.1 Testing.1 Unit

More information

Approved Contractor Construction e-guide Residential Commercial

Approved Contractor Construction e-guide Residential Commercial Approved Contractor Construction e-guide Residential Commercial Clark Public Utilities PO Box 8900 Vancouver, WA 98668 (PAGE 2) TABLE OF CONTENTS PAGE Trenching 3 Wire 8 Single-Phase Transformer Set 13

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 23 30 00 - HVAC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01 00, "Mechanical

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV) SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products

More information

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) PACKAGED PUMP SYSTEM WITH CAPACITIES TO 300GPM, PRESSURE BOOST TO 100PSI* WITH UP TO 25HP ON EACH PUMP AVAILABLE IN DUPLEX, AND TRIPLEX CONFIGURATION, AND

More information

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit Instruction Sheet 10-2004 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch.

More information

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified. SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear 13 Low Voltage Switchgear Siemens Type WL low voltage metal-enclosed switchgear is designed, constructed and tested to provide superior power distribution, power monitoring and control. At the heart of

More information

SECTION DISTRIBUTION AND GROUNDING

SECTION DISTRIBUTION AND GROUNDING SECTION 16400 DISTRIBUTION AND GROUNDING PART 1 GENERAL 1.01 SECTION INCLUDES A. Furnishing and installation of a complete electrical distribution and grounding system. B. Furnish and install motor control

More information

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Powergrid Solution s Metal Enclosed Switchgear has many different customizable options and configurations. Customers

More information

Low Voltage Automatic Transfer Switch Systems

Low Voltage Automatic Transfer Switch Systems Suitable for Emergency, Peak and Prime Power System Applications Low Voltage Automatic Transfer Switch Systems THE POWER AUTHORITY THE POWER AUTHORITY ASCO s experience and commitment to excellence in

More information

QUANTUM LX CONTROL PANEL

QUANTUM LX CONTROL PANEL Form E90-020 SPC (APR 2006) File: EQUIPMENT MANUAL - Section 90 Replaces: E90-020 SPC (JUN 2005) Dist: 1, 1a, 1b, 1c, 4a, 4b, 4c QUANTUM LX CONTROL PANEL The most technologically advanced screw compressor

More information

ASCO Low Voltage Automatic Transfer Switch Systems

ASCO Low Voltage Automatic Transfer Switch Systems ASCO Low Voltage Automatic Transfer Switch Systems Suitable for Emergency, Peak and Prime Power System Applications ASCO s experience and commitment to excellence in designing and building Emergency Power

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC

More information

CLIENT: PROJECT: PO#: ESTIMATOR:

CLIENT: PROJECT: PO#: ESTIMATOR: GENERATOR CONTROL DATA SHEET CLIENT: PROJECT: PO#: ESTIMATOR: PRIME MOVER FUEL: RPM: GOVERNOR SPEED ADJUST RHEOSTAT SUPPLIED WITH GOVERNOR: LOAD SHARING: REMOTE: PRIME MOVER PROTECTION LOW OIL PRESSURE

More information

take to complete our safety compliance

take to complete our safety compliance This presentation is one of three steps you will take to complete our safety compliance requirements ECR Energizer Contractor Representative Primaryliaison between Energizer and the contractor for matters

More information

AREA OF WORK ENERGY

AREA OF WORK ENERGY THIS DOCUMENT CONTAINS PROPRIETARY 408-859-545 AREA OF WORK THIS DOCUMENT CONTAINS PROPRIETARY Chlorking Chlor-25SM Controllers Chlorking & CO-2 controlled by chemical controller 3 x Chlorking Cells, 25

More information

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches An Investment in Plant Floor Safety 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches Notes 2 802C Cable Pull Safety Switches Safety and Application Safety

More information

SIGNAL WORDS QUALIFIED PERSON

SIGNAL WORDS QUALIFIED PERSON SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

APOLLO Gate Operators, Inc.

APOLLO Gate Operators, Inc. APOLLO Gate Operators, Inc. Model BA12 12 VOLT DC BARRIER ARM OPERATOR INSTALLATION MANUAL 0707 CONTENTS IMPORTANT SAFETY INSTRUCTIONS... 3 Applications... 4 Pre-Installation Checklist... 5 Operator Installation...

More information

Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification 1. General 1.1 This specification is for a fixed, medium-voltage, padmounted, three-phase power capacitor bank

More information

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Selection Checklist CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Use this checklist to help you configure your CENTERLINE 2500 Motor Control Center. You can type in the fields

More information

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1. SECTION 16120 WIRES AND CABLES 600 VOLTS AND BELOW PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Requirements for providing all wires and cables rated at 600 volts and below for complete electrical systems

More information

Document Requirements for Engineering Review PV Systems v1.0 6/9/2017

Document Requirements for Engineering Review PV Systems v1.0 6/9/2017 Document Requirements for Engineering Review PV Systems v1.0 6/9/2017 Outlined below are the documents and associated minimum details required for Engineering Review of Distributed Energy Resources Interconnection

More information

BID SPECIFICATIONS 2018 TERMINAL BUILDING STANDBY GENERATOR PROJECT

BID SPECIFICATIONS 2018 TERMINAL BUILDING STANDBY GENERATOR PROJECT BID SPECIFICATIONS 2018 TERMINAL BUILDING STANDBY GENERATOR PROJECT The County of Hancock, Maine is seeking bids from qualified firms for the purchase and installation of at least a 20KW backup generator

More information

.3 Section Waste Management and Disposal.

.3 Section Waste Management and Disposal. Issued 2005/06/01 Section 16261 Uninterruptible Power Systems Static Page 1 of 10 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

SECTION SWITCHGEAR. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

SECTION SWITCHGEAR. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes metal-enclosed,

More information

Waterlogix uses an OPLC which is an Operator Interface and PLC built into one low cost unit

Waterlogix uses an OPLC which is an Operator Interface and PLC built into one low cost unit Fountain LA Page 1 Waterlogix Tuesday, August 31, 2010 6:11 AM Waterlogix is a customizable Off the Shelf solution for automated Water Features Design and Manufactured by UL Listed General Control Systems,

More information

BP OIL -- TOLEDO REFINERY

BP OIL -- TOLEDO REFINERY BP OIL -- TOLEDO REFINERY Document Type: Procedure Effective Date: August 31, 2017 Owner: Dane P. Clark Refinery Wide Electrical Distribution System Switching and Isolation Auth. By: Rick J. Chmelovski

More information

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order Amphitheater High School Medium Voltage Switchgear Replacement Basis of Design 8/21/17 1of3 Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2

More information

SECTION HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS

SECTION HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS SECTION 08350 HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1

More information

Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification 1. General 1.1 This specification is for an automatic, medium-voltage, padmounted, three-phase power capacitor

More information

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS SECTION 22 1123.13 DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Typical Specification

Typical Specification Engineered to Order Built to Last Typical Specification VAULT VRPFI, TWO POSITION, ROTARY PUFFER SWITCHGEAR PART 1- GENERAL 1.1 DESCRIPTION A. The switch shall consist of manually operated load interrupting,

More information

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW Medium Voltage Product Overview MVB SERIES, MEDIUM VOLTAGE DRAW-OUT CIRCUIT BREAKER MVB SERIES Standard Breaker Features : 1200, 2000, 3000 Amps, 3 phase, 60

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements

More information

.3 Section Concrete Forms and Accessories: Installation of Anchor Devices, Setting Templates

.3 Section Concrete Forms and Accessories: Installation of Anchor Devices, Setting Templates Issued 2005/06/01 Section 16239 Power Generation to 30 kw Page 1 of 7 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01355 Waste Management and Disposal..2 Section 01810 Commissioning..3 Section 03100 Concrete

More information

Future Proof Your Arc Flash Assessment

Future Proof Your Arc Flash Assessment Future Proof Your Arc Flash Assessment 2017 ENERGY CONNECTIONS CONFERENCE TRADE SHOW Presented by: Keith Mullen, P.E. November 9, 2017 Agenda > Utility requirements > Study objectives > Applicable standards

More information

January 30, Ms. Safety Director Sample Medical Corp. PO Box X Somewhere, CT. Re: NFPA 70E Hazard Assessment. Date of Visit.

January 30, Ms. Safety Director Sample Medical Corp. PO Box X Somewhere, CT. Re: NFPA 70E Hazard Assessment. Date of Visit. 3018 Eastpoint Parkway Louisville, KY 40223 (502) 716-7073 January 30, 2006 Ms. Safety Director Sample Medical Corp. PO Box X Somewhere, CT Re: NFPA 70E Hazard Assessment Date of Visit January 24, 2006

More information

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

A. This section includes unit capacitors for power factor correction.

A. This section includes unit capacitors for power factor correction. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

Connect Series Accessories

Connect Series Accessories Connect Series Accessories 2015 Cummins Power Generation Inc. All rights reserved. Specifications are subject to change without notice. Cummins Power Generation and Cummins are registered trademarks of

More information

MaxSG Low Voltage Switchgear

MaxSG Low Voltage Switchgear Low Voltage Products & Systems Automation Technology MaxSG Low Voltage Switchgear ABB Automation Technologies MaxSG ABB Slide 2 June 2009 Product verview Key Features and Benefits Construction nstrumentation

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center Newport Harbor Mate Dimensions Height: 14.50" (368.30 mm) Width: 10.50" (266.70 mm) Depth: 10.40" (264.16 mm) Newport Harbor Mate Utility Center Diagram 2.77" Approximate Weight: 11 lbs. (5.0 kg) 10.31"

More information