Electrical distribution and safety for homes Catalogue SquareD Consumer units and protection devices
|
|
- Philippa Harrell
- 5 years ago
- Views:
Transcription
1 Electrical distribution and safety for homes Catalogue 2013 SquareD Consumer units and protection devices
2 SquareD EL Elegance and safety in perfect harmony 2
3 Innovation in residential switchboards Attractive and longlasting aesthetics for better integration in all places. White colour (UV protected) Modern and safe shape Plain or transparent door 4 available sizes. Split bus: electric shock protection made easy Split bus versions of SquareD EL come pre-equipped with Residual Current Device and its connection. Only circuits requiring protection from direct contacts are connected to the RCD. The other circuits with low direct contact risk remain supplied in case of trip. Convenient and error proof cabling Simple and cost effective solution Optimizing power supply availability. Installing and cabling still so simple Convenient cable entries: knockout precuts on back, top and bottom Exclusive "plug-on" connection system Effective cabling Supplied stickers for perfect circuit No compromise between design and safety Easy diagnosis when a circuit-breaker trips Quick diagnosis with "VisiTrip" fault indicator Non-flammable plastic material providing highresistance insulation from live parts identification. LED marker light automatically turned on in case of trip. SquareD EL offering Split bus* 4+4 ways 8+4 ways 8+8 ways (*) nr of non-rcd protected ways + nr of RCD protected ways. Single bus 4 ways 6 ways 10 ways 14 ways 18 ways 3
4 From: SquareD Square D, one of the first fuse builders in the USA, merges with Milwaukeebased Industrial Controller Company and begins producing circuit-breakers Introduction of the "plug-on" connection technology on circuit-breakers for distribution panel board The company opens new plants for manufacturing load dispatching centers and safety switches Agencies opened, and business expanding in Thailand, Singapore and Manila SquareD joins Schneider Electric Merlin Gerin Established as a high-voltage circuit -breaker designer and manufacturer in France Strong development of low voltage activities. The first Compact circuitbreakers appear on the market Birth of the Multi 9 modular switchgear range, for protection in industrial applications Expansion across Europe and overseas to become a global leader in electrical distribution During the last decade, services, solutions and products of Square D and Merlin Gerin gathered under Schneider Electric Brand Association of know-hows of these historical companies of the electrical domain enabled Schneider Electric to elaborate a complete catalogue of energy management solutions, to make energy ever more safe, reliable, efficient and productive Safe protecting you, your customers, your business Reliable uninterrupted, ultra-pure power at all time Efficient Up to 30% energy savings is now available Productive Simplicity and peace of mind 4
5 Today the worldwide leader of electrical protection technologies present in more than 100 countries. Just what you want from switchgear Quality - 100% designed and manufactured by Schneider Electric - All sites with ISO 9000 certification - Brand selected everywhere for industry, hospitals, airports. Customer satisfaction - Highly reliable and safe switchboards - Dependable power supply. Availability - Always on the shelf at your dealer s - Complete coverage of protection features - Large assortment of ratings. All former leading companies operate as one, under the brand of Schneider Electric 2012 to Schneider Electric The global specialist in energy management Safety - Protection from electric shocks, overloads, short-circuits, and power surges - Compliance to standards set by state authorities. Time saving - Consistent design and connection features - One-stop shopping for all parts - Proven robustness to withstand wear and tear Consumer units SquareD CL/EL p. 6 Main circuit-breakers SquareD QOvs/QO-MBX p. 8 3 Surge arrester SquareD QO-SPD p. 9 4 Main residual current circuit-breakers SquareD QO-MBGX p. 9 5 Branch circuit-breakers SquareD QOvs/QOH p Branch residual current device SquareD QOvs-RCBO p. 11 5
6 Consumer units SquareD CL Classic becomes SquareD CL Protection SquareD CL SquareD consumer units are designed to eliminate the use of back-up fuses. Only MCBs are used. The need to keep spare fuses is therefore not required and the errors in replacing with the wrong fuse rating is also prevented. The consumer unit (metal, square box, original blue color) that everyone familiar with. It's the original and the reference, trusted by all electricians over the last 30 years. It s why we called it "Classic". Only its name has changed. Bus bar current rating N of ways Cat no. 80 A 4 SDCS A 6 SDCS16 10 SDCS SDCS SDCS118 Blanking plate for 1 module (black)
7 SquareD EL New SquareD EL New Single bus CU with plain door* No. of way Cat no. 4 SDEL14 6 SDEL16 10 SDEL SDEL SDEL118 Split bus CU with plain door* Cat no. No. of way With RCBO Without RCBO MBGX 45 A - 30 ma MBGX 63 A - 30 ma 4+4 SDEL14X4MBGX45 SDEL14X4MBGX63 SDEL14X4RCD 8+4 SDEL18X4MBGX45 SDEL18X4MBGX63 SDEL18X4RCD 8+8 SDEL18X8MBGX45 SDEL18X8MBGX63 SDEL18X8RCD * For transparent door add "T" at the end of catalogue numbers Accessories Cat no. Big terminal lug for < 50 Sq.mm. earth cable SDALUG50 LED option - "marker light" MIP99050 Common characteristics > > Quick and easy to install supplied complete > > Comply with IEC 60439, BS5486 part 13 and TIS > > 1.2 mm thick Phosphate-coated sheet SPCC preventing corrosion and finishing with epoxy paint thickness of µm > > Type tested to 10 ka prospective short-circuit current (240 V 50/60 Hz) > > Cable entry knock-outs provided. > > Polycarbonate dolly cover supplied as standard > > All busbars tinned copper plated > > Neutral and earth terminal bars pre-installed, ready to use > > Blanking plates are supplied to close spare ways > > Meet most of the requirement for residential and commercial > > IP4x degree of protection. Spare parts Cat no. Pictogram labels SDAPIC 4 modules blanking plates SDABP Gland plate SDAGP Cover + door Plain (for retrofitting purpose) 4 ways SDACOV14P 6 ways SDACOV16P 10 ways SDACOV110P 14 ways SDACOV114P Cover + door Transparent (for retrofitting purpose) 4 ways SDACOV14T 6 ways SDACOV16T 10 ways SDACOV110T 14 ways SDACOV114T 7
8 Main circuit-breakers SquareD QOvs SquareD QO-MBX Protection SquareD QOvs 16 to 63 A Common characteristics > > All circuit-breakers fit into all Consumer Units > > Easy installation and maintenance. Plug-on circuit-breakers provide positive connection to the busbar in one quick operation, saving up to 50% on wiring and connection time > > Short-circuit instantaneous trip type C > > Rated voltage up to 240 Vac 50/60 Hz > > Comply with relevant standards > > The exclusive VisiTrip indicator provides clear and instant identification of the tripping status on the circuit-breaker. > > Isolation and switching > > Protection of circuits against cable overloads and short-circuits. Perfect for residential sector use > > Complies with IEC > > Plug-on connection system > > VisiTrip indicator provides clear and instant identification of the tripping status on the circuit-breaker > > Quick-break closing contacts, for enhanced life duration > > Number of operating cycles (O-C): -- Mechanical 20,000 at 1,200 cycles/hour -- Electrical 4,000 at 240 cycles/hour < 32 A and 120 cycles/hour > 32 A > > Impulse withstand voltage (U.imp): 6 kv > > Tropicalization: treatment 2 (relative humidity 95% at 55 C) > > Common pole on tripping. Poles Voltage Current rating Breaking capacity (Icn) Cat no. (V) (A) 10,000 A (10 ka) Icn (ka) Ics (%Icn) 2P % QO216VSC10T % QO220VSC10T % QO232VSC10T % QO240VSC10T % QO250VSC10T % QO263VSC10T SquareD QO-MBX 70 to100 A > > Isolation and switching > > Protection of circuits against cable overloads and short-circuits. Perfect for residential sector use > > Complies with IEC > > Plug-on connection system > > VisiTrip indicator provides clear and instant identification of the tripping status on the circuit-breaker > > Common pole on tripping. Breaking capacity (Icn) Current rating Cat no. (ka) (A) QO270MBXT 80 QO280MBXT 100 QO2100MBXT 8
9 Surge arrester SquareD QO-SPD Main residual current circuit-breakers SquareD QO-MBGX SquareD QO-SPD Type 2 surge protection for all residential, small commercial and office buildings > > Protection of electronic devices (TVs, HI-FI equipment, games consoles, computers, household electrical appliances) against destruction by lightning > > Protection of all the circuits served by the consumer > > Easy to install with plug-on system without any modification - can be directly fitted in consumer unit. Technical characteristics Compliance with standards IEC Maximum discharge current rating 15 ka Nominal discharge current rating 6 ka Level of protection (Up) 1.5 kv Short-circuit current rating 25,000 rms Amperes, 320 Volts Max. Joule rating 1440 Thermal fusing Yes Operating frequency 50 Hz Operating temperature -4 to +150 F (-20 to + 65 C) Power consumption per phase 786 mw at 320 V Diagnostics Green Status LED Product weight 0.54 lb / 0.25 kg Cat no. QO-SPD225 SquareD QO-MBGX Residual Current Device with Integrated Overcurrent Protection > > Protection against cable overloads, short-circuits and electric shocks. Perfect for residential sector use > > Isolation and switching > > Compliant with IEC and TIS > > Plug-on connection system > > VisiTrip indicator provides clear and instant identification of the tripping status on the circuit-breaker > > Residual Current Protection: rated sensitivity 30 ma > > A push-to-test button on the front of the device for checking operation of internal tripping circuitry and mechanism. Double pole SquareD QO-MBGX Breaking Residual Current Cat no. capacity current sensitivity rating (ka) (ma) (A) QO216MBGX30T 20 QO220MBGX30T 32 QO232MBGX30T 45 QO245MBGX30T 63 QO263MBGX30T 9
10 Branch circuit-breakers SquareD QOvs SquareD QOH Protection SquareD QOvs 10 to 63 A Why it has to be "PLUG-ON" system? > > Commonly used in Thailand and USA as standard practice for so many years > > 50% reduction on installation time compares to a lug/lug DIN alternative > > No link bars to fit and tighten > > Contact jaws automatically align the circuitbreakers in the equipment > > High short-circuits result in an increase in jaw pressure reducing the potential for hazardous arcs on the side of the circuit-breaker > > More flexibility and lower labour costs due to the time reduction. > > Same characteristics as "SquareD QOvs 16 to 100 A" in page 8. Type Voltage Current rating Short-circuit capacity (Icn) (V) (A) 6,000 A (6 ka) 10,000 A (10 ka) Icn Ics Cat no. Icn Ics Cat no. (ka) (%Icn) (ka) (%Icn) 1P % QO110VSC6T * 10 75% QO110VSC10T % QO116VSC6T * 10 75% QO116VSC10T % QO120VSC6T * 10 75% QO120VSC10T % QO125VSC6T 10 75% QO125VSC10T % QO132VSC6T * 10 75% QO132VSC10T % QO140VSC6T 10 75% QO140VSC10T % QO150VSC6T 10 75% QO150VSC10T % QO163VSC6T 10 75% QO163VSC10T 3P % QO310VSC6T 10 75% QO310VSC10T % QO316VSC6T 10 75% QO316VSC10T % QO320VSC6T 10 75% QO320VSC10T % QO325VSC6T 10 75% QO325VSC10T % QO332VSC6T 10 75% QO332VSC10T % QO340VSC6T 10 75% QO340VSC10T % QO350VSC6T 10 75% QO350VSC10T % QO363VSC6T 10 75% QO363VSC10T * For Project, add "PT" instead of "T" at the end of catalogue numbers SquareD QOH 70 to 100 A > > Protection of circuits against cable overloads and short-circuits. Perfect for residential sector use > > Complies with IEC > > Plug-on connections > > Rated voltage: 240 V 50/60 Hz > > VisiTrip indicator provides clear and instant identification of the tripping status on the circuit-breaker > > Common pole on tripping. SquareD QOH-X Cat no. Breaking capacity (ka) Current rating (A) 1 pole 6 70 QOH170XT 80 QOH180XT 100 QOH1100XT 10
11 Branch residual current device SquareD QOvs-RCBO SquareD QOvs-RCBO > > Protection against cable overloads, short-circuits, and electric shocks > > Complies with IEC and TIS > > Plug-on connection system > > Rated voltage: 240 V 50/60 Hz > > Residual current protection: choice of 10 or 30 ma rated sensitivity > > Push-button on front of the device for checking operation of internal tripping circuitry and mechanism > > Short-circuit tripping curve type C: magnetic trip unit operates between 5 and 10 In. SquareD QOvs-RCBO Cat no. Breaking capacity Current rating Residual current sensitivity (ka) (A) 10 ma 30 ma 6 10 QO110vs6RCBO10 QO110vs6RCBO30 16 QO116vs6RCBO10 QO116vs6RCBO30 20 QO120vs6RCBO10 QO120vs6RCBO30 32 QO132vs6RCBO10 QO132vs6RCBO30 40 QO140vs6RCBO10 QO140vs6RCBO30 45 QO145vs6RCBO10 QO145vs6RCBO QO110vs10RCBO10 QO110vs10RCBO30 16 QO116vs10RCBO10 QO116vs10RCBO30 20 QO120vs10RCBO10 QO120vs10RCBO30 32 QO132vs10RCBO10 QO132vs10RCBO30 40 QO140vs10RCBO10 QO140vs10RCBO30 45 QO145vs10RCBO10 QO145vs10RCBO30 11
12 Make the most of your energy Schneider Electric Industries SAS 35, rue Joseph Monier CS F Rueil Malmaison Cedex France RCS Nanterre Capital social CA909003E As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. Publishing: Schneider Electric Industries SAS Photos: Schneider Electric Industries SAS Printing: Printed on ecological paper Schneider Electric - All rights reserved.
Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient
Medium voltage NEX switchgear Withdrawable circuit breaker Quite simply efficient NEX, a simple and flexible solution NEX is the result of worldwide acquired experience and provides you with a high level
More informationDomae. The right solution for distribution boards
Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationOffers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants
devices Offers This page must be removed before publishing The Schneider Electric residual current devices range comprises various offers (A, B, C, D) so as to be as competitive as possible in each country,
More informationI B D Q I B D Q O I B D Q O
Extension offer: new possible combinations 2 and 3 functions RM6 free combination: offers all types of configurations which fit to every application. Free choice: type of each functional unit. Free choice:
More informationXL 3 -N SimPly, EfficiEnt And SAfE. 3 - PHASE distribution boards up to 250 A
XL 3 -N 125 250 SimPly, EfficiEnt And SAfE 3 - PHASE distribution boards up to 250 A the global specialist in ElEctricAl And digital building infrastructures Xl 3 -n Comprehensive and reliable range for
More informationTeSys Enclosed Starters. Let TeSys ensure safety in your simple motor applications
TeSys Enclosed Starters Let TeSys ensure safety in your simple motor applications TeSys Innovative and intuitive solutions to protect, monitor and control The TeSys range is suitable for motor and power
More informationRelax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.
Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE Distributor : LEGRAND ELECTRIC LIMITED Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 CONSUMER UNIT BRO.10.05.??K
More informationand other modular devices for low voltage installation
Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories
More informationNew DX 3 High rating & breaking capacity
New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand
More informationschneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.
K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles
More informationDX³ 4-pole RCBO 6000 A/10 ka
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationNEW TX³ RANGE PROTECTION YOU CAN RELY ON
TX³ NEW RANGE TRUSTED PROTECTION FOR YOUR INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW TX³ RANGE PROTECTION YOU CAN RELY ON Designed to meet the requirements of
More informationGreater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE
Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE Summary of changes Simplifying the 17 th Edition Understanding new regulations is never easy... that s why we ve tried to
More informationSimple and smart power factor correction
Simple and smart power factor correction VarSet Low voltage capacitor banks VarSet I 2 Do you need an easy solution to immediately boost your facility s energy efficiency and productivity? Are products
More informationCompact NR630. NR100F to NR630F
Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS
More informationTeSys Enclosed Starters. Let TeSys watch over your machinery
TeSys Enclosed Starters Let TeSys watch over your machinery Standard offer applications: Fans, blowers, ventilators Pumps: water pumps, heat pumps, etc. Compressors Elevators Automatic gates, roof window
More informationPIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution
Medium Voltage Distribution PIX Withdrawable Voltage Transformer Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual Nr. Edition 11/2011 www.schneider-electric.com Schneider
More informationDSE201 Compact design with enhanced protection
DSE201 Compact design with enhanced protection The best of safety DSE201 6 ka: the highest level of reliability The 1P+N electronic residual current circuit-breakers with overcurrent protection (RCBOs)
More informationGROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations
TP&N DISTRIBUTION BOARD TYPE B Distribution boards for modern commercial & industrial installations TP&N DISTRIBUTION BOARD - TYPE B Designed & Engineered in the UK Compliant to BS EN 61439-3:2012 Supplied
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More informationCertified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers
Certified for best-in-class performance, reliability, and safety Trihal sets a new standard for dry-type cast resin transformers Setting a new standard for dry-type cast resin transformers hospitals wind
More informationPDL s DBF AND DBS SERIES DISTRIBUTION BOARDS
PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS FEATURES Robust, durable construction Unique double doors open 180 with minimum projection Light grey colour standard, can be painted to suit décor re quirements
More informationThe PowerLogic wireless range is designed to retrofit existing switchboards, and enhance energy efficiency of buildings in operation for many years.
em4300 series The PowerLogic wireless range is designed to retrofit existing switchboards, and enhance energy efficiency of buildings in operation for many years. It achieves this by monitoring energy
More informationMulti 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com
Multi 9 TM Catalogue 207 Multistandard protection for OEM schneider-electric.com Green Premium TM Endorsing industry eco-friendly products Schneider Electric s Green Premium ecolabel is committed to offering
More informationic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi
Contents Miniature circuit breakers ic60n miniature circuit breakers 6kA, C curve, 6-63A ic60h miniature circuit breakers 10kA, C curve, 6-63A ic60n miniature circuit breakers 6kA, B curve, 6-63A ic60h
More informationConsumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations
Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations POWER DISTRIBUTION AND PROTECTION NHP Electrical Engineering Products Pty Ltd AUS NZ 1300
More informationHVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015
Medium Voltage Distribution Catalogue 205 HVX Series 36 kv Medium Voltage Vacuum circuit breaker Fixed, middle rolling and floor rolling ranges of circuit breaker and disconnector Make the most of your
More information020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)
020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service
More informationDX³ RCBO 4500/6 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationGHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel
Gas-Insulated Switchgear GHA Gas-Insulated Switchgear Switchgear extension and replacement of a panel During this work, essential parts of the switchgear remain in operation No. AGS 535 066-01 Edition
More informationCOMPLETE SOLUTIONS FOR POWER PROTECTION
COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX
More informationCBGS-0. Medium voltage distribution
Medium voltage distribution CBGS-0 Gas Insulated metal-enclosed Switchgear SF6 circuit breaker technology Up to 24/36 kv - 1250/1600/2000 A - 25/31.5 ka Transmission Wind Airports Oil & Gas Mining & Distribution
More informationGAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura
GAE CLAD \ METALCLAD SWITCHGEAR up to 24 kv \ M600204.15 PT Guna Era Manufaktura Catalogue 2015 GAE CLAD Vacuum Circuit Breaker With Embedded Poles Metal - Clad Switchgear Up To 24 kv General Description
More information87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS
87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationResidential and light commercial. invicta. panelboards
Residential and light commercial invicta panelboards Your simple energy distribution solution As an industry leader in power distribution, we strive to create innovative products that make installations
More informationDX³ RCBO 6000 A Phase + Neutral, neutral right side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1
More informationConsumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations
MEMT Memera full metal consumer units and protective devices Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations Memera full metal consumer units and protective
More informationSTANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011
Page 1 of 6 STANDARD SPECIFICATION FOR LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs Rev No. Issue Date Pages Rev Description Prepared By Checked By Approved By 0 15.07.2008 6 Issued for FEED MSJ VDV VDV
More informationDS201 - DS202C New residual current circuit-breakers with overcurrent protection (RCBOs)
DS201 - DS202C New residual circuit-breakers with over protection (RCBOs) New residual circuit-breakers with over protection (RCBOs) - DS201 - DS202C 1P+N and 2P in two modules. Complete protection To
More informationStudy and operate the protection features associated with the neutral plans with manual troubleshooting. S.L.T.-TR22 Bench
Study and operate the protection features associated with the neutral plans with manual troubleshooting S.L.T.-TR22 Bench 1. Presentation of the kit This bench illustrates the rationale underlying the
More informationIntelligent Choice for Prestigious Buildings
Intelligent Choice for Prestigious Buildings Table of Contents I-LINE Moulded Case Circuit Breakers General Characteristics 16A to 160A 125A to 250A 250A to 600A 300A to 800A 630A to 1250A 2/3 4 5 6 6
More informationSentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification
543 technical hotline +44 ()1268 56372 Standards and approvals Sentry MCBs are designed to fully comply with the relevant requirements of BS EN 6898: 23. They all feature positive contact status indication
More informationMCset 17.5 kv. Civil engineering guide April Medium Voltage Distribution
Medium Voltage Distribution MCset 17.5 kv ir insulated switchboard Withdrawable switchgear SF6 or vaccum technology Civil engineering guide pril 2012 Contents General 2 Glossary 2 Dimensions and weights
More informationQUALITY ASSURANCE & DOCUMENTATION
QUALITY ASSURANCE & DOCUMENTATION RTECK IMPORTED PRODUCT STATEMENT Rteck has sourced most product from a large and reputable Chinese product manufacturer who specialise in the manufacture of modular electrical
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More information013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS
013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification
More informationR.C.B.O. SP / 1 module
87045 LIMOGES Cedex - France Telephone : (+33) 5 55 06 87 87 Fax : (+33) 5 55 06 88 88 R.C.B.O. SP / 1 module 6064 04 6064 64 05 6064 10 6064 11 6064 12 CONTENTS PAGES 1. Description, use... 1 2. Range...
More informationC60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V
DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used
More informationDATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT
44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7
More informationNXPLUS C Single busbar. Maintenance-free for lifetime
NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage
More informationAIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE
AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE Certificate Number FM35831 APPLICATION Typical Uses and Classification The MSGair switchgear is used in transformer and switching substations mainly
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationMiniature Circuit Breaker
Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the
More informationMINIATURE CIRCUIT BREAKER
Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.
More informationBTPLUG 2 CATALOGUE 2009 BTP2_09TH
BTPLUG 2 CATALOGUE 2009 BTP2_09TH Content BTPLUG2 Catalogue 2009 BTPLUG2 safety and innovation 4 Protection in residential and tertiary application 5 BTPLUG2 internal structure 6 BTPLUG2 feature 7 BTPLUG2
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationDX³ RCBO 6000A Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationEquipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module
transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short
More informationPrisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter
3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice
More informationWiring devices Asfora 2015 catalogue
Wiring devices 05 catalogue Contents Presentation Products with cover frame (white, cream) Switches and push-buttons 6 Socket-outlets 8 Communication outlets 9 Dimmers 0 ccessories Products without cover
More informationRX 3 MCB 4500 A Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationMedium Voltage Distribution FBX. Assembling a 1250A busbar Instructions.
Medium Voltage Distribution FBX Assembling a 1250A busbar Instructions www.schneider-electric.com Contents Introduction... 3 Our Service Unit: our specialists, and suitably adapted services...... 3 Overview...
More informationLow Voltage A GE Power Controls Company. General catalogue
Low Voltage A GE Power Controls Company General catalogue this is a blanc page Miniature circuit breakers A Miniature circuit breakers AC miniature circuit breakers Benefits of the new MCB s A 3 The AEG
More informationDX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 / 10 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationResidual current devices
Residual devices FH00 Plus of range /30 Technical features table /3 Ordering information /34 Technical details /37 DS01 and DS0C Plus of range /38 Technical features table /40 Ordering information DS01
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationSeries KTU7 UL489 Molded Case Circuit Breakers
Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed
More informationInstantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch
Features (1) All models fully comply with IEC regulations (2) Units can be mounted on a standard 35mm IEC rail (3) Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable
More informationCOMBINATION CIRCUIT BREAKERS RCBO
COMBINATION CIRCUIT BREAKERS RCBO W COMBINED MCB AND RCCB, SERIES BOLF W CONTACT POSITION INDICATOR 108 TYPE EAN CODE FOR QUICK ORDERING TRIP INDICATOR WHITE/BLUE CONTACT POSITION INDICATOR RED/GREEN W
More informationElectrical network management. Schneider Electric. Acti 9 iem2000 Technical Datasheet
Electrical network management Schneider Electric Acti 9 iem2000 Technical Datasheet PB110836 PB108401 The Acti 9 iem2000 and iem2100 Series offer a cost-attractive, competitive range of single-phase DIN
More informationGet detailed information on many digital or printed supports, or contact your Area Commercial Manager
The RX 3 and DX-E ranges provide essential functions for the protection requirements of people and property in residential and small commercial buildings Two breaking capacities, 4500 and 6000 (IEC 60898-1)
More informationDRX 125 Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.
More informationMedium Voltage Distribution Catalogue Flusarc Make the most of your energy
Medium Voltage Distribution Catalogue 2012 Flusarc 40.5 Make the most of your energy Flusarc switchgear 40.5 kv - 630 A - 20 ka General contents Overview 3 General characteristics 7 Description 11 Installation
More informationBtdin-RS RCBO 2p Phase + Neutral, neutral on right
Viale Borri 231, 21100 Varese - Italy RCBO 2p CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1 5. General characteristics... 2 6. Compliance
More informationMINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS
MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY
More informationPower systems Protection course
Al-Balqa Applied University Power systems Protection course Department of Electrical Energy Engineering Dr.Audih 1 Part 3 Protective Devices Fuses & Circuit Breakers 2 Introduction: Fuse Is advice used
More informationMolded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV
The recloser you want, all in one package. Single- and Three-Phase, 15 38kV The need for automated reclosers has never been greater, but many of today s reclosers come with penalties. They weigh too much,
More informationProtection and Connection Motorized and automatic transfer switches IEC Technical guide
Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety
More informationDRX 250 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.
More informationMCset kv Medium voltage equipment
Maintenance Guide PE90014 PE90006 MCset 1-2 - 3 17.5 kv Medium voltage equipment Air-insulated switchboards Metal-enclosed switchgear with moving parts PE90007 PE90008 PE90009 PE90007 Maintenance Guide
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationThe effective choice The benefits of a product with the highest quality standards
The effective choice The benefits of a product with the highest quality standards Compact size for easy installation in small spaces and retrofitting of already existing facilities. Terminals designed
More informationTeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com
TeSys D, K Catalogue 2017 'S335' series contactors for electrodomestic applications schneider-electric.com Presentation TeSys D, TeSys K TeSys D, TeSys K: S335 series Best-in-class contactors for electrodomestic
More informationMoulded Case Circuit Breakers
Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field
More informationPRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004
PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3
More informationThe Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs
[ MV Air-insulated Switchgear Range ] 1 PIX CUSTOMER BENEFITS Compact, versatile and highly reliable designs Choice of vacuum or SF6 switching technology Wide range of applications Enhanced operator safety
More informationDPX 1600 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationP SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE
P SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE A BREAKER PROTECTION BREAKTHROUGH Simplify flameproof protection for lighting, heat trace and power circuit distribution with the new generation
More informationGalaxy VM. Battery Breaker Box Installation 09/
Galaxy VM Battery Breaker Box Installation 09/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred
More informationUniGear. Technical Guide
UniGear Technical Guide CONTENTS 0 CONTENTS 1.1 Compartments 1/2 1.2 Components of the structure 1/3 1.2.1 Hot-galvanized steel sheet 1/3 1.2.2 Painted steel sheet 1/4 1.2.3 Copper 1/5 1.2.4 Insulating
More informationProtection and control VIP30, VIP35. Relays technical manual
Protection and control VIP30, VIP35 Relays technical manual contents 1. presentation of the VIP30 and VIP35...3 2. use and settings...4 3. sensors and operating ranges... 4. connection scheme...9 5. assembly
More informationCircuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories
Circuit Breakers BZM Product Information Circuit Breaker BZM1 16 to 125 A Circuit Breaker BZM2 125 to 250A BZM1 & BZM2 Accessories Optimum and Efficient Protection for Every Application Compact Simple
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More informationWall mounted switchgear
Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page
More informationLow Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A
Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection
More informationNEXT GENERATION LOAD CENTER
NEXT GENERATION LOAD CENTER Safe, Reliable and High Quality LOAD CENTER AND CIRCUIT BREAKER WITH ENCLOSURE CATALOG SAFE RELIABLE HIGH QUALITY DIRA believes that the only way to CONTENTS Load Center 03
More information