ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi
|
|
- Priscilla Paul
- 5 years ago
- Views:
Transcription
1
2 Contents Miniature circuit breakers ic60n miniature circuit breakers 6kA, C curve, 6-63A ic60h miniature circuit breakers 10kA, C curve, 6-63A ic60n miniature circuit breakers 6kA, B curve, 6-63A ic60h miniature circuit breakers 10kA, B curve, 6-63A C68N miniature circuit breakers 6kA, C curve, 6-63A C68N miniature circuit breakers 6kA, B curve, 6-63A C120N miniature circuit breakers 10kA, C curve, A Electrical auxiliaries & accessories Residual current devices ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi Command control devices isw power switches PRF1, PRD 1 & iprd surge arresters PF surge arresters itl, itlc, itlm, itls impulse relays, changeover relays & auxiliaries Enclosures MCB boards technical specifications Multipact MCB boards Multipact MCB boards/accessories
3 A9F74116 A9F74220 A9F74316 Type Wid. in mod. of 9mm Rated current 1-pole 2 6 A9F A9F A9F A9F A9F A9F A9F A9F A9F pole 4 6 A9F A9F A9F A9F A9F A9F A9F A9F74 63 A9F pole 6 6 A9F A9F A9F A9F A9F A9F A9F A9F A9F74363 Application Control and protection of circuits against overloads and short circuits : in domestic installations; in commercial and industrial electrical distribution systems. rated current : 6-63A set at 40 ; tripping characteristics : C curve : the magnetic releases operate at 8 In ±20%; breaking capacity (IEC/EN 60947, IEC/EN 60898) : Rated Type Voltage (V) Breaking current (A) capacity (ka) pole /3-pole limitation class : 3; number of operating cycles (O-C) : 20000; tropicalisation : treatment 2 (relative humidity 95% at 55 ); weight (g) : Type 1-pole 2-pole 3-pole connections : tunnel terminals for the following cables 16mm 2 flexible or 25mm 2 rigid up to 25A ratings, 25mm 2 flexible or 35mm 2 rigid for 32-63A ratings; complies with IEC/EN 60947, IEC/EN ± /
4 A9F84116 A9F A9F Type Wid. in mod. of 9mm Rated current 1-pole 2 6 A9F A9F A9F A9F A9F A9F A9F A9F A9F pole 4 6 A9F A9F A9F A9F A9F A9F A9F A9F84 63 A9F pole 6 6 A9F A9F A9F A9F A9F A9F A9F A9F A9F84363 Application Control and protection of circuits against overloads and short circuits : in domestic installations; in commercial and industrial electrical distribution systems. rated current : 6-63A set at 40 ; tripping characteristics : C curve : the magnetic releases operate at 8 In ±20%; breaking capacity (IEC/EN 60947, IEC/EN 60898) : Rated Type Voltage (V) Breaking current (A) capacity (ka) pole /3-pole limitation class : 3; number of operating cycles (O-C) : 20000; tropicalisation : treatment 2 (relative humidity 95% at 55 ); weight (g) : Type 1-pole 2-pole 3-pole connections : tunnel terminals for the following cables 16mm 2 flexible or 25mm 2 rigid up to 25A ratings, 25mm 2 flexible or 35mm 2 rigid for 32-63A ratings; complies with IEC/EN 60947, IEC/EN In ± /
5 A9F73116 A9F73216 A9F73316 Type Wid. in mod. of 9mm Rated current 1-pole 2 6 A9F A9F A9F A9F A9F A9F A9F A9F A9F pole 4 6 A9F A9F A9F A9F A9F A9F A9F A9F73 63 A9F pole 6 6 A9F A9F A9F A9F A9F A9F A9F A9F A9F73363 Application Control and protection of circuits against overloads and short circuits : in domestic installations; in commercial and industrial electrical distribution systems. rated current : 6-63A set at 40 ; tripping characteristics : B curve : the magnetic releases operate at 4 In ±20%; breaking capacity (IEC/EN 60947, IEC/EN 60898) : Rated Type Voltage (V) Breaking current (A) capacity (ka) pole /3-pole limitation class : 3; number of operating cycles (O-C) : 20000; tropicalisation : treatment 2 (relative humidity 95% at 55 ); weight (g) : Type 1-pole 2-pole 3-pole connections : tunnel terminals for the following cables 16mm 2 flexible or 25mm 2 rigid up to 25A ratings, 25mm 2 flexible or 35mm 2 rigid for 32-63A ratings; complies with IEC/EN 60947, IEC/EN ±20% /
6 A9F83116 A9F83210 A9F83320 Type Wid. in mod. of 9mm Rated current 1-pole 2 6 A9F A9F A9F A9F A9F A9F A9F A9F A9F pole 4 6 A9F A9F A9F A9F A9F A9F A9F A9F83 63 A9F pole 6 6 A9F A9F A9F A9F A9F A9F A9F A9F A9F83363 Remarks : of 4-pole, C or D curves circuit breaker can be provided upon request. Application Control and protection of circuits against overloads and short circuits : in domestic installations; in commercial and industrial electrical distribution systems. rated current : 6-63A set at 40 ; tripping characteristics : B curve : the magnetic releases operate at 4 In ±20% ; breaking capacity (IEC/EN 60947, IEC/EN 60898) : Rated Type Voltage (V) Breaking current (A) capacity (ka) pole /3-pole positive contact indication; number of operating cycles (O-C) : 20000; tropicalisation : treatment 2 (relative humidity 95% at 55 ); weight (g) : Type 1-pole 2-pole 3-pole connections : tunnel terminals for the following cables 16mm 2 flexible or 25mm 2 rigid up to 25A ratings, 25mm 2 flexible or 35mm 2 rigid for 32-63A ratings; complies with IEC/EN 60947, IEC/EN ±20% /
7 Type Wid. in mod. of 9mm Rated current 1-pole pole pole t (s) H I/In Application Control and protection of circuits against overloads and short circuits : in domestic installations; in commercial and industrial electrical distribution systems. rated current : 6-63A set at 40 ; tripping characteristics : C curve : the magnetic releases operate between 5 and 10 In; breaking capacity (IEC 60898) : Rated Type Voltage (V) Breaking current (A) capacity (ka) pole /3-pole limitation class : 3; number of operating cycles (O-C) : 20000; tropicalisation : treatment 2 (relative humidity 95% at 55 ); weight (g) : Type 1-pole 2-pole 3-pole connections : tunnel terminals for the following cables 16mm 2 flexible or 25mm 2 rigid up to 25A ratings, 25mm 2 flexible or 35mm 2 rigid for 32-63A ratings; complies with IEC /
8 Type Wid. in mod. of 9mm Rated current 1-pole pole pole Application Control and protection of circuits against overloads and short circuits : in domestic installations; in commercial and industrial electrical distribution systems. rated current : 6-63A set at 40 ; tripping characteristics : B curve : the magnetic releases operate between 3 and 5 In; breaking capacity (IEC 60898) : Rated Type Voltage (V) Breaking current (A) capacity (ka) pole /3-pole limitation class : 3; number of operating cycles (O-C) : 20000; tropicalisation : treatment 2 (relative humidity 95% at 55 ); weight (g) : Type 1-pole 2-pole 3-pole connections : tunnel terminals for the following cables 16mm 2 flexible or 25mm 2 rigid up to 25A ratings, 25mm 2 flexible or 35mm 2 rigid for 32-63A ratings; complies with IEC /
9 A9N18359 Type Wid. in mod. of 9mm Rated current 1-pole 3 80 A9N A9N A9N pole 6 80 A9N A9N A9N pole 9 80 A9N A9N A9N18369 rated current : A; tripping characteristics : C curve : the magnetic releases operate between 5 and 10 In; breaking capacity (IEC 60898) : 10kA; limitation class : 3; number of operating cycles (O-C) : 5000; connections : 35mm 2 flexible cable or 50mm 2 rigid cables; complies with IEC & IEC A9N18369 Electrical Auxiliaries Type Wid. in mod. of 9mm Voltage V AC V DC imx + OF A9A26946 shunt trip release A9A A9A26948 imn undervoltage release instantaneous A9A26960 iof contact auxiliary A9A26924 isd fault indicating switch A9A26927 iof + SD/OF changeover A9A26929 Electrical Auxiliaries Auxiliaries enable remote tripping or remote indication of the ON/OFF position of a miniature circuit breaker. They are mounted by clipping on the left hand side of the same circuit breaker with: maximum of 3 indication auxiliaries iof, isd; maximum of 2 changeover contacts (iof + SD/OF); maximum of 1 iof + SD/OF changeover contact and 1 indication auxiliary iof or isd; maximum of 2 tripping auxiliaries (imx + OF, imx, imn) Accessories Type Extended rotary handle (mounted on door or hinged panel) ic60 padlock device (bag of 2 pcs) A9A27005 A9A
10 A9D Type C A A9D Type C A A9D Type C A A9D Type C A A9D Type C A A9D Type C A A9D Type C A A9D61845 Application Protection and control circuits against overloads, short circuits and earth leakage faults in commercial, industrial and household's electrical distribution systems. The RCBO provides : protection against indirect contact; complementary protection against direct contact (16th Edition ); rated voltage : 240V; operating voltage : V; rated current : 6-45A; tripping characteristics (BS EN 60898) : C curve : the magnetic releases operate between 5 and 10 In; breaking capacity : BS EN kA; limitation class : 3; lockable in "ON" or "OFF" position; trip free mechanism; complies with BS EN 61009, IEC 1009; test button operates between times rate voltage. 70mm 20mm 110mm 18mm 9
11 A9D Type C A A9D Type C A A9D Type C A A9D Type C A A9D Type C A A9D Type C A A9D Type C A A9D mm 18mm 70mm 20mm Application Protection and control circuits against overloads, short circuits and earth leakage faults in commercial, industrial and household's electrical distribution systems. The RCBO provides : protection against indirect contact; complementary protection against direct contact (16th Edition ); rated voltage : 240V; operating voltage : V; rated current : 6-45A; tripping characteristics (BS EN 60898) : C curve : the magnetic releases operate between 5 and 10 In; breaking capacity : BS EN kA; limitation class : 3; lockable in "ON" or "OFF" position; trip free mechanism; complies with BS EN 61009, IEC 1009; test button operates between times rate voltage. 10
12 A9R71263 A9R74463 Type Wid. in mod. of 9mm Rated current Sensitivity 2-pole A9R A9R A9R A9R A9R A9R pole A9R A9R A9R A9R A9R A9R74463 Application The iid residual current devices provide the functions of isolation, switching and earth leakage protection of electrical circuits. They have a residual current operated electromechanical release which operates without any auxiliary source of supply to open a circuit automatically in the case of an earth leakage fault between phase and earth greater than or equal to a threshold of 10, 30, 100, 300 or 500mA. rated current : A; rated voltage : 2-pole : V, 4-pole : V; unwanted tripping : all iid/rccb incorporate a filter device preventing the risks of unwanted tripping due to transient voltages (lightning, line disturbances on other equipment) and transient currents (from high capacitive circuit); isolation and switching; positive contact indications : in accordance with 15th edition of the IEE Wiring Regulations (Regs 537-5, 537-9); operating temperature : -5 to +60 ; connections : tunnel terminals for 25mm 2 fiexible cables or 35mm 2 for rigid cables; number of operating cycles (O-C) : 20000; tropicalization : treatment 2 (relative humidity 95% at 55 ); weight (g) : Type 2-pole 4-pole RCD : BS 4293 : 1983, CEE 27, BS EN 60898, IEC 1008, EN 61008; CEE 27 range : NF-USE, KEMA, OVE, SEMKO, DEMKO, NEMKO, FI; BS range : ASTA
13 A9D31606 Type Wid. in mod. of 9mm C curve / C 1P + N 4 Rated current Sensitivity A9D31606 A9D31610 A9D31616 A9D31620 A9D31625 A9D31632 A9D31640 Function ; carries out complete protection of final circuits (overcurrents and insulation faults): protection of persons against indirect contact (30 or 300mA), protection of installations against fire hazards (300mA), additional protection of persons against direct contact (30 ma); ; voltage rating : 230 V AC; breaking capacity : EN 60898/EN : - rated breaking capacity (Icn) : 6 ka ratings : 4-40A at 30 ; fast closing; positive contact indication; earth fault visualised on front face; durability (O-C cycles) : mechanical : 20000, electrical : I 20 A : 20000, I 25 A : environment : tropicalisation : treatment 2 (relative humidity: 95% at 55 ); weight : 125g; connection : tunnel terminals for 10 mm 2 flexible or 16 mm 2 rigid cable; approvals : KEMA KEUR C curve tripping curve : the magnetic trip units operate between 5 and 10 In C curve / C 12
14 A9S65240 A9S65340 Type 1-pole 2-pole 3-pole 4-pole Wid. in mod. of 9mm Rated Current!" #$ %""!" #$ %""!" #$ %""!" #$ %"" Voltage A9S65140 A9S65163 A9S65191 A9S65240 A9S65263 A9S65291 A9S65340 A9S65363 A9S65391 A9S65440 A9S65463 A9S65491 Function on-load opening and closing of a circuit. positive contact indication; DC use : 48V (110V two serial poles); mechanical endurance : I=40-100A: cycles, electrical endurance : AC22 p.f.=0.6, I=40, 63A : cycles, I=100A : cycles, rated short-time withstand : 20 x ln : 1 sec; tropicalization : treatment 2 (95% relative humidity at 55 ); connections : tunnel terminals for the following cables 50mm 2 rigid cables for A, 35mm 2 flexible cables for A; complies with IEC standard for A; approvals : USE; utilization category : AC22A. 13
15 pole + N 3-pole + N PRF1 12.5r PRD1 25r PRF1 12 PRD1 25r / / /100 (N-PE) 25/100 (N-PE) 12.5/100 (N-PE) 25/100 (N-PE) 1-pole + N 3-pole + N PRD1 Master 230 PRD1 Master 230/ /100 (N-PE) 25/100 (N-PE) PRF1 Function PRF1 Type 1 surge arresters protect electrical installations against direct lightning strokes. It is recommended for electrical installations in buildings protected by a lightning conductor. PRF1 type 1 surge arresters are tested under shock current (Iimp) with a 10/350!s wave form. "1!s; PRD Functions PRD Removable Type 2 surge arresters protect electrical installations against indirect lightning strokes. PRD surge arresters are tested under full discharge current (Imax) with a 8/20!s wave form pole + N 1+ 3-pole + N 3+ PRD 65r PRD 40r PRD 40 PRD 20r PRD 20 PRD 8r PRD 65r PRD 40r PRD 40 PRD 20r PRD 20 PRD 8r!s Yes Yes No Yes No Yes Yes Yes No Yes No Yes , ; "25 ns.!s "1!s C C C C8-340 C neutral C1 Master-350 C1 Neutral-350 C C PRD65r PRD40, PRD40r PRD20, PRD20r PRD8, PRD8r All PRD PRD1 Master PRD1 Master, PRD1 25r PRD1 25r PRD1 25r !s "25 ns
16 pole + N 1+ 3-pole + N 3+ PF 65 PF 40 PF 20 PF 65r PF 65 PF 40r PF 40 PF 20!s No No No Yes No Yes No No !s wave form "25 ns!s " 15
17 A9C30812 A9C30115 A9C32316 Type Wid. in mod. of 9mm Coil voltage V AC V DC itl 16A Impulse Relays 1-pole A9C A9C pole A9C A9C A9C A9C A9C pole A9C A9C A9C A9C A9C A9C A9C A9C pole A9C A9C32816 itli 16A Changeover Relays 1-pole itl 32A Impulse Relays 1-pole A9C pole A9C A9C pole A9C (2 x A9C32836) 4-pole A9C (3 x A9C32836) ietl 16A Extensions ietl A9C A9C A9C A9C32016 ietl 32A Extensions ietl A9C32836 itlc 16A Impulse Relays 1-pole 2 24 A9C A9C A9C33811 Type Coil voltage V AC V DC Add-on Auxiliaries iatls Indication iatlm Latched Order Control iatlz Control by Pushbuttons iatlc+c Multi-level Control Function impulse relays allow circuit remote control : via impulse orders (mechanically latched); from several control points; impulse relays are used for the control of resistive circuits (incandescent lamps, low voltage halogen lamps, convectors) and inductive circuits (fluorescent tubes, discharge lamps). impulse duration : 50ms; maximum switching frequency : 5 operations/minute; operating temperature : -20 to +50 ; tropicalization : treatment 2 (relative humidity 95% at +55 ); switching noise level : < 60dBA (at 1 m). 16
18 SPN MCB/RCBO Boards & Consumer Units Bar Ratings B10006R. No. of way Dimensions H W D B10006R B10008R B10010R B10012R B10014R B10016R B10202R B10303R B10044R B10084R B10104R B10106R
19 Multipact Bar Ratings w/o Main Switch Space B11006R No. of way Dimensions H W D B11004R B11006R B11008R B11010R B11012R B11014R B11016R TPN MCB/RCBO Board Bar Ratings c/w Main Switch Space B12106R No. of way To fit M/S Dimensions H W D B12104R B12106R B12108R B12110R B12112R B12114R B12116R B12118R B12120R B12122R B12112RM160 B12114RM160 B12116RM160 B12118RM160 B12112RM B12114RM B12116RM B12118RM B12112RM160 Bar Ratings c/w Main Switch & RCD Spaces B13206 (B11... /B12... /B13... boards) ; ;. No. of way Dimensions H W D B13202 B13204 B13206 B13208 B13210 B13212 B13404 B13406 B13408 B13410 B13412 B13414 B13416 B13418 B13606 B13608 B13610 B13612 B13614 B13616 B13808 B13810 B13812 B
20 Bar Ratings c/w Main Switch Space B17112R No. of way To fit M/S Dimensions H W D B17104R B17106R B17108R B17110R B17112R B17114R B17116R B17118R B17120R B17122R A 100A 100A 100A 100A 100A 100A 100A 100A 100A No. of way Dimensions H W D B14006 B14004 B14001 B14003 B14004 B14006 B14008 B14010 B14012 B14014 B x 4P 3 x 4P 4 x 4P 6 x 4P 8 x 4P 10 x 4P 12 x 4P 14 x 4P 16 x 4P B15160 Application Dimensions H W D B15160 INS B15 INS Bar Ratings w/o Main Switch Space B16304 B16206 No. of way Dimensions H W D B x 2P B x 2P B x 2P B x 3P + N B x 3P + N B x 3P + N B19001 B19002 B19001 B A AI switch tee busbar Blanking plate for 6 SP MCB Description
21
22
23
24 Schneider Electric (HK) Ltd. 13th Floor, East Wing, Warwick House, Taikoo Place, 979 King's Road, Quarry Bay, Hong Kong SEHK/DOC/MCB16 05/2013
Low voltage. Acti 9. the efficiency you deserve. Multi 9 > Acti 9 Cross-reference guide
Low voltage Acti 9 the efficiency you deserve Multi 9 > Acti 9 Cross-reference guide Acti 9 ic60h Circuit Breakers 10kA Type B Characteristic ic60h circuit breakers are multi standard circuit breakers
More informationContents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...
Contents Acti 9 MCBs, RCCB ic60h circuit breakers (curve B, C, D)... pages / to /4 ic60h and ic60h RCB0 10, 30 and 100 ma.... pages /5 to /8 Vigi ic60 add-on residual current devices.... pages /9 to /1
More informationPDL s DBF AND DBS SERIES DISTRIBUTION BOARDS
PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS FEATURES Robust, durable construction Unique double doors open 180 with minimum projection Light grey colour standard, can be painted to suit décor re quirements
More informationC60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V
DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used
More informationDomae. The right solution for distribution boards
Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:
More informationschneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.
K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More information87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS
87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084
More informationand other modular devices for low voltage installation
Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories
More informationGet detailed information on many digital or printed supports, or contact your Area Commercial Manager
The RX 3 and DX-E ranges provide essential functions for the protection requirements of people and property in residential and small commercial buildings Two breaking capacities, 4500 and 6000 (IEC 60898-1)
More informationResidual Current Circuit-breaker (RCCB) FH 200 Series
Residual Current Circuit-breaker (RCCB) FH 200 Series Bi-directional cylindrical terminal ensure higher safety of connecting operations, making them easier. Test pushbutton to verify the correct functioning
More informationmax pole for t=15 ms
Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole
More informationDSE201 Compact design with enhanced protection
DSE201 Compact design with enhanced protection The best of safety DSE201 6 ka: the highest level of reliability The 1P+N electronic residual current circuit-breakers with overcurrent protection (RCBOs)
More informationCOMPLETE SOLUTIONS FOR POWER PROTECTION
COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX
More informationLEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1
More informationDX³ 4-pole RCBO 6000 A/10 ka
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationWall mounted switchgear
Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page
More informationTechnical Journal September 2012
Technical Journal September 2012 Earth leakage protection in polluted low voltage network In present day irrespective of the application be it in process industry or in IT industry, Pollution of electrical
More informationMS25, MST25, MS20, MST20
Motor protection switches MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers
More informationInterchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
. Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,
More informationMINIATURE CIRCUIT BREAKER
Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.
More informationBtdin RCBO 6000A up to 63A (2P)
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-
More informationConsumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations
Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations POWER DISTRIBUTION AND PROTECTION NHP Electrical Engineering Products Pty Ltd AUS NZ 1300
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationOffers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants
devices Offers This page must be removed before publishing The Schneider Electric residual current devices range comprises various offers (A, B, C, D) so as to be as competitive as possible in each country,
More informationR.C.B.O. SP / 1 module
87045 LIMOGES Cedex - France Telephone : (+33) 5 55 06 87 87 Fax : (+33) 5 55 06 88 88 R.C.B.O. SP / 1 module 6064 04 6064 64 05 6064 10 6064 11 6064 12 CONTENTS PAGES 1. Description, use... 1 2. Range...
More informationEquipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module
transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short
More informationMulti 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com
Multi 9 TM Catalogue 207 Multistandard protection for OEM schneider-electric.com Green Premium TM Endorsing industry eco-friendly products Schneider Electric s Green Premium ecolabel is committed to offering
More informationCharacteristics of LV circuit breakers Releases, tripping curves, and limitation
Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break
More informationReady to install Distribution boards, DIN rail mounted equipment, enclosures and connection systems
Ready to install Distribution boards, DIN rail mounted equipment, enclosures and connection systems Contents Isobar 4 distribution boards and protective devices Section one 7 Modular control products Section
More informationCat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090
More informationDPX 1600 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationQUALITY ASSURANCE & DOCUMENTATION
QUALITY ASSURANCE & DOCUMENTATION RTECK IMPORTED PRODUCT STATEMENT Rteck has sourced most product from a large and reputable Chinese product manufacturer who specialise in the manufacture of modular electrical
More informationDX³ RCCBs - ID 4P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationMS25, MST25, MS20, MST20
Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers
More informationThe effective choice The benefits of a product with the highest quality standards
The effective choice The benefits of a product with the highest quality standards Compact size for easy installation in small spaces and retrofitting of already existing facilities. Terminals designed
More informationNew DX 3 High rating & breaking capacity
New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY
More informationBtdin-RS RCBO 2p Phase + Neutral, neutral on right
Viale Borri 231, 21100 Varese - Italy RCBO 2p CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1 5. General characteristics... 2 6. Compliance
More informationDX³ RCBO 4500/6 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationInstantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch
Features (1) All models fully comply with IEC regulations (2) Units can be mounted on a standard 35mm IEC rail (3) Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable
More informationMINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS
MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY
More informationPRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004
PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3
More informationLow Voltage A GE Power Controls Company. General catalogue
Low Voltage A GE Power Controls Company General catalogue this is a blanc page Miniature circuit breakers A Miniature circuit breakers AC miniature circuit breakers Benefits of the new MCB s A 3 The AEG
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationEAD10H80D EAD14H80D EAD17H80D
12.4 Technical data Consumer units and enclosures dimensions and data RCCB controlled surface mounting consumer units Eaton list Dimensions (mm) number w h d EAD2/3M63 154 223 101 EAD2/3M80 EAD4M63 235
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationProtection components
Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed
More informationRESIDUAL CURRENT CIRCUIT BREAKER
Quality Features Mid Trip - Different knob position to indicate whether the device is Switched OFF by a fault or Switched OFF manually Inscription Window - Ensures circuit identification and hence reduces
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationl Suitable for most residential, commercial and light industrial applications
538 Consumer Units and Enclosures Standards and approvals All Sentry consumer units are designed to fully comply with the requirements of BS EN 60439-3. Weatherproof enclosures are designed to fully comply
More informationIP20 degree of protection; IP40 degree of protection after installation in a distribution box
RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationRX 3 M.C.B A up to 63 A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationNEW TX³ RANGE PROTECTION YOU CAN RELY ON
TX³ NEW RANGE TRUSTED PROTECTION FOR YOUR INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW TX³ RANGE PROTECTION YOU CAN RELY ON Designed to meet the requirements of
More informationResidual current devices
Residual devices FH00 Plus of range /30 Technical features table /3 Ordering information /34 Technical details /37 DS01 and DS0C Plus of range /38 Technical features table /40 Ordering information DS01
More informationRX 3 M.C.B A up to 63 A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...
More informationGE Consumer & Industrial Power Protection. New. ElfaPlus Unibis. Compact MCB s. Saving up to 50% space in distribution boards. GE imagination at work
GE Consumer & Industrial Power Protection New ElfaPlus Unibis Compact MCB s Saving up to 50% space in distribution boards GE imagination at work 2 Advantages 6 Miniature circuit breakers - Series EPC
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationSentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification
543 technical hotline +44 ()1268 56372 Standards and approvals Sentry MCBs are designed to fully comply with the relevant requirements of BS EN 6898: 23. They all feature positive contact status indication
More informationEffective discrimination of protective devices
Effective discrimination of protective devices In the event of a fault occurring on an electrical installation only the protective device nearest to the fault should operate,leaving other healthy circuits
More informationDX³ RCBO 6000 A Phase + Neutral, neutral right side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1
More informationMCBs and RCDs LR TM 6000
MCBs and RCDs LR TM 6000 thermal magnetic MCBs from 6 A to 63 A B and C curves residual current devices from 25 A to 63 A AC and A types ± ± ± ± MCBs Single pole 230/400 V± Single pole neutral 230 V± (1)
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationRX 3 MCB 4500 A Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationDMX 3 -I 2500 switch disconnectors
8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40
More informationBreaking and protection devices
Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply
More informationUnit price (incl.vat) in VND Domae MCB - 1P/1P+N, 4.5kA & 6kA, 230/240V Domae MCB 1P. 4.5kA Reference 112, DOM , DOM11341
Domae MCB, RCCB P,P+N, P, P & P MCBs for control and protection of circuits against overloads and short-circuits Residential, Houses, Office applications etc... Compliance with IEC 898, C Curve Impulse
More informationPerfection that Matters
Perfection that Matters Switchgear Range Catalogue 2017 Contents Power Series Distribution Boards Classique Distribution Boards Miniature Circuit Breaker Isolator Residual Current Circuit Breaker Residual
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationC 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers
SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection
More informationTX³ RCCBs 2P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationTechnical catalogue. System pro M. Residual current devices 2CSC420001D0201
Technical catalogue System pro M Residual current devices 2CSC42000D020 SUMMARY Residual current devices Technical details and guide to applications Overall dimensions 2 3 ABB SACE and its commitment to
More informationCat N 3. OVERALL DIMENSIONS
Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1
More informationProtectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.
Types MS116, MS132, MS5x, MS9x are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/OFF control, and protection against short circuit,
More informationIntroduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction
Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection
More informationDPX 630 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationxboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications
xboard commercial and industrial panelboards xboard effectively combining safety, reliability and performance safety, reliability and performance in commercial and industrial applications NEW xboard (xdb)
More informationDPX 630 Thermal magnetic and trip-free switches DPX-I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More information01 Spectra Plus - Introduction
01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from
More informationProduct index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.
Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type
More informationDX³ RCBO 6000A Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationBasic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors
MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided
More informationDX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data
Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC
More informationElectrical distribution and safety for homes Catalogue SquareD Consumer units and protection devices
Electrical distribution and safety for homes Catalogue 2013 SquareD Consumer units and protection devices SquareD EL Elegance and safety in perfect harmony 2 Innovation in residential switchboards Attractive
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationActi 9 the efficiency you deserve
Low voltage Acti 9 the efficiency you deserve Catalogue 09/2013 Acti 9 Contents General Principle of catalogue numbers, protection (Acti 9) CA901009E 1 Circuit protection Choice of circuit protective devices
More informationSpecification for 70mm pole pitch Air circuit breaker up to 1600 A
Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with
More informationME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage
Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144
More informationMiniature circuit 3.2 breakers 6kA type B SP. Miniature circuit 3.3 breakers curve B,C&D 10kA and 15kA. Protection Devices
Miniature circuit 3.2 breakers 6kA type B SP Miniature circuit 3.3 breakers curve B,C&D 10kA and 15kA Auxiliaries and 3.5 accessories Protection Devices RCCB add-on blocks 3.6 Miniature cicruit 3.8 breakers
More informationic60a circuit breakers (curve C)
(curve ) DB9 DB98 DB99 DB88 IE/EN 097- IE/EN 0898- ountry approval pictograms PB09-0 PB09-0 bb are multi-standard circuit breakers which combine the following functions: vvcircuit protection against short-circuit
More informationRange 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000
The flow of current through electrical facilities always involves risks. Poorly insulated equipment, faulty wires and incorrect use of an electrical devise cause currents to flow through the wrong path
More information(1,5 modules per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationMain catalogue. Distribution Innovation
Main catalogue Distribution Innovation Contents The family... 2 3 Miniature circuit-breakers - General, technical data... 6 9 - Order data... 10 19 Residual current operated circuit-breakers - Residual
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More informationRelax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.
Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE Distributor : LEGRAND ELECTRIC LIMITED Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 CONSUMER UNIT BRO.10.05.??K
More informationDRX 125 Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.
More informationModular contactors and relays
pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation
More information