Study and operate the protection features associated with the neutral plans with manual troubleshooting. S.L.T.-TR22 Bench

Size: px
Start display at page:

Download "Study and operate the protection features associated with the neutral plans with manual troubleshooting. S.L.T.-TR22 Bench"

Transcription

1 Study and operate the protection features associated with the neutral plans with manual troubleshooting S.L.T.-TR22 Bench

2

3 1. Presentation of the kit This bench illustrates the rationale underlying the current regulations and standards concerning the physical protection of individuals as regards the TN or TT systems (first working surface) and the IT system (second working surface). 1.1 Overview On each of the totally independent surfaces, 3 single or three-phase receivers have been represented, with protection devices based on magneto-thermal circuit-breaker, differential circuit-breakers, differential switches, contactors. Power resistors and a rehostat located in the base of the bench are connected to the panel by cables (supplied) fitted with safety jacks for operations under the supervision of a qualified teacher. 3/11

4 1.2 Characteristics Mechanical characteristics Dimensions: height: 1700 mm, width: 700 mm, depth: 700 mm Weight: 120 kg Electrical characteristics The bench is powered by a 400 V three-phase electrical network with earth power 4 kva. Voltage: 400 V three-phase ± 10 % Frequency: 50 Hz ± 5 % Current: 16 A, connection by 3P + earth socket The conventional short-circuit current is set to 10 ka. Rated impulse withstand voltage: 2,5 kv Protection class: l The electrical network must be fitted with a RCD (Residual Current Device) of sensitivity 30 ma of AC class upstream the bench (not supplied). Technical characteristics of built-in components Isolation controller Vigilohm TR22A V Transformers Transformer 48VA P : 230/400V S : 24 V 2 Star-triangle three phase transformer Circuit breaker Three pole magneto-thermal circuit-breaker 4 to 6,3A Two pole magneto-thermal circuit-breaker 1A and 0,5A Four pole circuit breaker 16A Three pole circuit breaker 10A Two pole circuit breaker 12A, 0,5 et 6A Differential bipolar circuit breaker 240V 25A 10mA 4/11

5 1.3 Functional description The S.L.T.-TR22 bench allows the users to perform exercises on the various neutral plans. The two surfaces may be used at the same time, one for TN and TT neutral plans exercises, the other for the IT neutral plan exercises. Two single-phase receivers (R1 and R2) and a three-phase receiver have been represented. It has been assumed, for the sake of clarity and to assist in training, that receivers are in premises of various classes. The R3 receiver is supposed to be installed in fire risk premises. The user can then perform the various exercises on the two surfaces of the bench as well as on the power resistors located in the base of the bench. 5/11

6 2. Teaching 2.1 Teaching presentation S.L.T.-TR22 Bench allows: Theoretical study of the various neutral plans. Circuit cabling and study of device responses On the IT neutral plan: manual troubleshooting system. It is intended to the following studies: Automated Systems Industrial Computing Professional High School University & Engineering school Monitoring and Regulation Electrical Engineering Engineering Equipment Energy Industrial Maintenance Automated Production Mechanical Industrial Automated Systems Miscellaneous Industrial Automated Systems Exercises to be performed from the S.L.T.-TR22 bench: The exercises are composed of a teacher document and a student document. TT neutral plan: Interconnection and earthing of groundings are necessary conditions but not sufficient to ensure protection. The magneto-thermal circuit breakers do not ensure the protection against the indirect contacts. The use of a RCD is a necessary condition but not sufficient to ensure protection (threshold selection). The use of a RCD is a necessary condition but not sufficient to ensure protection (RA maximum value). Selective activation by RCD located at various level. The earthing connection values must be measured regularly. Fire risk. Mobile receivers. TN neutral plan: An earth fault leads to an overcurrent which is eliminated by standard circuit breakers. Does a given circuit-breaker ensure protection in every case? What to do if the conditions are not fulfilled? 6/11

7 IT neutral plan: Interconnection and grounds earthing are necessary and sufficient conditions for protection in the case of first fault. Permanent insulation monitoring of the network with respect to the earth and indication of the first. Single fault: search for the faulty feeder by successive short opening of the various circuit-breakers. Single fault: search for the faulty feeder by injection of AC current at very low frequency. Double fault: circuit breaker protection is insufficient for long feeders (example p.8 to 10). Double fault: need to provide RCDs on long feeders. 7/11

8 2.2 Teaching examples 8/11

9 9/11

10 10/11

11 3. Items provided with the kit 3.1 Equipment provided A ready-to-use S.L.T.-TR22 bench assembly with two double-sided working surface reference MDG A set of safety cables 3.2 Documentation A technical manual (reference MDG9AD604) A tutorial handbook (reference MDG9AD605) 4. Name and address Schneider Electric France Activité Didactique 3F 35 rue Joseph Monier CS Rueil Malmaison - France Indigo phone No.: FR-didactic@fr.schneider-electric.com 11/11

Identify electrical hazards and operation on an electrical installation. Valhabilis

Identify electrical hazards and operation on an electrical installation. Valhabilis Identify electrical hazards and operation on an electrical installation Valhabilis 1. Presentation of the Equipment The Valhabilis equipment is made up of two complementary cases representing an electrical

More information

Galaxy VM. Battery Breaker Box Installation 09/

Galaxy VM. Battery Breaker Box Installation 09/ Galaxy VM Battery Breaker Box Installation 09/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred

More information

I B D Q I B D Q O I B D Q O

I B D Q I B D Q O I B D Q O Extension offer: new possible combinations 2 and 3 functions RM6 free combination: offers all types of configurations which fit to every application. Free choice: type of each functional unit. Free choice:

More information

BC IMPREGO Impregnated dry type transformers and autotransformers

BC IMPREGO Impregnated dry type transformers and autotransformers atalogue B IMPREGO Impregnated dry type transformers and autotransformers Low Voltage Distribution schneider-electric.com LV transformers and autotransformers Tailored to your needs ontents Your requirements

More information

Electrical network protection VIP30, VIP35. User s manual 12/2008

Electrical network protection VIP30, VIP35. User s manual 12/2008 Electrical network protection VIP30, VIP35 User s manual 1/008 Safety instructions ANSI symbol. IEC symbol. Safety symbols and messages Read these instructions carefully and look at the equipment to become

More information

Galaxy VX Battery Breaker Trip Board (GVXBBTB) and Battery Breaker Capacitor Board (GVXBBCB)

Galaxy VX Battery Breaker Trip Board (GVXBBTB) and Battery Breaker Capacitor Board (GVXBBCB) Installation 990 91076 001 12/2017 Galaxy VX Battery Breaker Trip Board (GVXBBTB) and The battery breaker trip board is the interface from the battery bank to the UPS battery auxiliary inputs/outputs and

More information

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel Gas-Insulated Switchgear GHA Gas-Insulated Switchgear Switchgear extension and replacement of a panel During this work, essential parts of the switchgear remain in operation No. AGS 535 066-01 Edition

More information

EVlink Parking EVF1 - EVW1

EVlink Parking EVF1 - EVW1 EVlink Parking EVF1 - EVW1 Parking Charging Stations User Manual 07/2013 EVF1ppppppp EVW1ppppppp DOCA0063EN-01 www.schneider-electric.com This document contains general descriptions and/or general technical

More information

Galaxy 300 Battery Breaker Kit G3HTBKIT1

Galaxy 300 Battery Breaker Kit G3HTBKIT1 Installation 990 5739 001 03/2016 990 5739 001 Galaxy 300 Battery Breaker Kit G3HTBKIT1 What s in This Document Important Safety Instructions SAVE THESE INSTRUCTIONS...1 Safety Precautions...2 Specifications...4

More information

MCset 17.5 kv. Civil engineering guide April Medium Voltage Distribution

MCset 17.5 kv. Civil engineering guide April Medium Voltage Distribution Medium Voltage Distribution MCset 17.5 kv ir insulated switchboard Withdrawable switchgear SF6 or vaccum technology Civil engineering guide pril 2012 Contents General 2 Glossary 2 Dimensions and weights

More information

Effective discrimination of protective devices

Effective discrimination of protective devices Effective discrimination of protective devices In the event of a fault occurring on an electrical installation only the protective device nearest to the fault should operate,leaving other healthy circuits

More information

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS 87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

R.C.B.O. SP / 1 module

R.C.B.O. SP / 1 module 87045 LIMOGES Cedex - France Telephone : (+33) 5 55 06 87 87 Fax : (+33) 5 55 06 88 88 R.C.B.O. SP / 1 module 6064 04 6064 64 05 6064 10 6064 11 6064 12 CONTENTS PAGES 1. Description, use... 1 2. Range...

More information

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs [ MV Air-insulated Switchgear Range ] 1 PIX CUSTOMER BENEFITS Compact, versatile and highly reliable designs Choice of vacuum or SF6 switching technology Wide range of applications Enhanced operator safety

More information

Electrical distribution and safety for homes Catalogue SquareD Consumer units and protection devices

Electrical distribution and safety for homes Catalogue SquareD Consumer units and protection devices Electrical distribution and safety for homes Catalogue 2013 SquareD Consumer units and protection devices SquareD EL Elegance and safety in perfect harmony 2 Innovation in residential switchboards Attractive

More information

TeSys Enclosed Starters. Let TeSys ensure safety in your simple motor applications

TeSys Enclosed Starters. Let TeSys ensure safety in your simple motor applications TeSys Enclosed Starters Let TeSys ensure safety in your simple motor applications TeSys Innovative and intuitive solutions to protect, monitor and control The TeSys range is suitable for motor and power

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

Galaxy Receiving and Unpacking 09/

Galaxy Receiving and Unpacking 09/ Galaxy 5500 20 120 kva 400 V Receiving and Unpacking 09/2015 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS

More information

Earthing Principles. Symmetra PX 250/500 kw

Earthing Principles. Symmetra PX 250/500 kw Earthing Principles Symmetra PX 250/500 kw Table of Contents Earthing Principles... 1 Decoding the Earthing Types... 1 TN Systems... 2 Characteristics... 2 Reference to IEC/EN 60364-4-41 413.1.3... 2

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

CBGS-0. Medium voltage distribution

CBGS-0. Medium voltage distribution Medium voltage distribution CBGS-0 Gas Insulated metal-enclosed Switchgear SF6 circuit breaker technology Up to 24/36 kv - 1250/1600/2000 A - 25/31.5 ka Transmission Wind Airports Oil & Gas Mining & Distribution

More information

TeSys Enclosed Starters. Let TeSys watch over your machinery

TeSys Enclosed Starters. Let TeSys watch over your machinery TeSys Enclosed Starters Let TeSys watch over your machinery Standard offer applications: Fans, blowers, ventilators Pumps: water pumps, heat pumps, etc. Compressors Elevators Automatic gates, roof window

More information

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6 The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 6 PROTECTIONS 1 FUNCTION OF ELECTRICAL PROTECTION SYSTEMS Problems:

More information

New DX 3 High rating & breaking capacity

New DX 3 High rating & breaking capacity New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand

More information

Galaxy Installation 08/

Galaxy Installation 08/ Galaxy 5000 40 130 kva 480 V Installation 08/2017 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred to

More information

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS RCBOs - Residual current circuit breakers with integral overcurrent protection KZS Advantages of residual current circuit breakers with integral overcurrent protection KZS - 1M Combining the features of

More information

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015 Medium Voltage Distribution Catalogue 205 HVX Series 36 kv Medium Voltage Vacuum circuit breaker Fixed, middle rolling and floor rolling ranges of circuit breaker and disconnector Make the most of your

More information

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric. K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles

More information

Schneider Electric Conext SW

Schneider Electric Conext SW Schneider Electric Inverter/Charger Applications for the New Value in off-grid solar and backup power solutions Conext TM SW delivers new value and a new price point to the marketplace in 2013. is a pure

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Minera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards

Minera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards Minera Oil distribution transformers up to 3 150 kva Minera at a glance Mineral oil-immersed, 50 Hz, three-phase distribution transformers with the following characteristics: Hermetically sealed with integral

More information

Schneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant

Schneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant Schneider Electric PV Skid Optimized solar power conversion system tailored to enhance any North American PV power plant 1 PV Skid solution Integrated solution designed for optimal performance in any environment

More information

Medium Voltage Distribution Catalogue Flusarc Make the most of your energy

Medium Voltage Distribution Catalogue Flusarc Make the most of your energy Medium Voltage Distribution Catalogue 2012 Flusarc 40.5 Make the most of your energy Flusarc switchgear 40.5 kv - 630 A - 20 ka General contents Overview 3 General characteristics 7 Description 11 Installation

More information

SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS.

SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS. SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS Róbert Riedlmajer TRNAVA 2007 Unit 14 - Fundamentals of power system protection

More information

Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)

Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD) Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD) Schneider Electric RCBO Earth Leakage Circuit Breaker (ELCB) An Earth Leakage Circuit Breaker (ELCB) is a device

More information

WUEKRO. Training & Didactic Systems. Protection Schemes DIN VDE 0100

WUEKRO. Training & Didactic Systems. Protection Schemes DIN VDE 0100 Training & Didactic Systems Protection Schemes DIN VDE 0100 Catalog WA2E/08 Table of Contents Page Our Services, Customers and Scope of Supply 2 Introduction 4 Protection Schemes according to DIN VDE 0100

More information

Galaxy VM. Modular Battery Cabinets Installation GVMMODBCW, GVMMODBCN 09/

Galaxy VM. Modular Battery Cabinets Installation GVMMODBCW, GVMMODBCN 09/ Galaxy VM Installation GVMMODBCW, GVMMODBCN 09/2018 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and

More information

CPG.0 Single busbar gas-insulated cubicles

CPG.0 Single busbar gas-insulated cubicles MV Switchgear Primary Distribution CPG.0 Single busbar gas-insulated cubicles Up to 36 kv CPG System The quality of products designed, manufactured and installed by Ormazabal is underpinned by the implementation

More information

Power IT Compact Secondary Substations, CSS. Low Voltage Switchboard, LVS2

Power IT Compact Secondary Substations, CSS. Low Voltage Switchboard, LVS2 Power IT Compact Secondary Substations, CSS Low Voltage Switchboard, LVS2 LVS ABB s New Low Voltage Switchboard for Power IT CSS LVS2 is a freestanding low voltage switchboard, as it is designed with a

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

Medium Voltage Distribution FLUSARC P-LA. Up to 36 kv 630 A 25 ka. Catalogue 2010

Medium Voltage Distribution FLUSARC P-LA. Up to 36 kv 630 A 25 ka. Catalogue 2010 Medium Voltage Distribution FLUSARC P-LA Up to 36 kv 630 A 25 ka Catalogue 2010 FLUSARC P-LA Contents Overview... 3 General description... 3 Features... 3 Main advantages... 3 Customer benefits... 3 Operating

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Domae. The right solution for distribution boards

Domae. The right solution for distribution boards Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:

More information

Accelerate your grid modernization with smart RMUs. Ring main units with smart grid-ready feeder automation

Accelerate your grid modernization with smart RMUs. Ring main units with smart grid-ready feeder automation Accelerate your grid modernization with smart RMUs Ring main units with smart grid-ready feeder automation schneider-electric.com/smart-rmu Contents > Take charge of your grid evolution For deployment

More information

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com TeSys D, K Catalogue 2017 'S335' series contactors for electrodomestic applications schneider-electric.com Presentation TeSys D, TeSys K TeSys D, TeSys K: S335 series Best-in-class contactors for electrodomestic

More information

Compact NR630. NR100F to NR630F

Compact NR630. NR100F to NR630F Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS

More information

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A Indoor switches for railway lines single-pole design rated voltage up to 27,5 kv rated current up to 4000 A General These Driescher indoor switching devices are specifically designed for railway applications.

More information

INTRODUCTION. AC motor operations, most widely used motor is three phase induction motor. This type of motor does not require any starting device

INTRODUCTION. AC motor operations, most widely used motor is three phase induction motor. This type of motor does not require any starting device Modular Application (AC Motors) Engineering and Technical Teaching Equipment AEL-AI12 INTRODUCTION An electrical motor is such an electromechanical device which converts electrical energy into a mechanical

More information

Signal Power Supply Monitoring & Restoration

Signal Power Supply Monitoring & Restoration Signal Power Supply Monitoring & Restoration Automatic Supply Restoration (ASR) systems operate in two ways: Protection based systems that handle a fault in real time. Post fault restoration systems that

More information

DSE201 Compact design with enhanced protection

DSE201 Compact design with enhanced protection DSE201 Compact design with enhanced protection The best of safety DSE201 6 ka: the highest level of reliability The 1P+N electronic residual current circuit-breakers with overcurrent protection (RCBOs)

More information

Galaxy VM. Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017.

Galaxy VM. Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017. Galaxy VM Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

PIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution

PIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution Medium Voltage Distribution PIX Withdrawable Voltage Transformer Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual Nr. Edition 11/2011 www.schneider-electric.com Schneider

More information

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager The RX 3 and DX-E ranges provide essential functions for the protection requirements of people and property in residential and small commercial buildings Two breaking capacities, 4500 and 6000 (IEC 60898-1)

More information

Btdin RCBO 6000A up to 63A (2P)

Btdin RCBO 6000A up to 63A (2P) Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-

More information

The switchboard that your installation deserves

The switchboard that your installation deserves The switchboard that your installation deserves Blokset : Low voltage switchboard for electrical distribution and motor control 2 A tried and tested switchboard Blokset switchboards have long guaranteed

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering University of Sydney School of Electrical and Information Engineering Dr Keith Mitchell ELEC 5205 - High Voltage Engineering ELEC 5205 - High Voltage Engineering 3. Switchgear Types of Power System Switchgear

More information

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show.

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show. 1 PAPER 7 Sample Questions - C&G 2382 17th Edition paper C 1 o/c 1 - BS 7671 relates to permanent and temporary installations for equipment on: a marinas. b ships. c equipment on aircraft. d railway traction

More information

Medium Voltage Distribution FBX. Assembling a 1250A busbar Instructions.

Medium Voltage Distribution FBX. Assembling a 1250A busbar Instructions. Medium Voltage Distribution FBX Assembling a 1250A busbar Instructions www.schneider-electric.com Contents Introduction... 3 Our Service Unit: our specialists, and suitably adapted services...... 3 Overview...

More information

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers Certified for best-in-class performance, reliability, and safety Trihal sets a new standard for dry-type cast resin transformers Setting a new standard for dry-type cast resin transformers hospitals wind

More information

Square D General Purpose Relays

Square D General Purpose Relays Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................

More information

EVlink. Cluster Cabinet Including EVlink MS Energy Management and EVlink MS Supervision Recommendation Guide 04/2013.

EVlink. Cluster Cabinet Including EVlink MS Energy Management and EVlink MS Supervision Recommendation Guide 04/2013. EVlink DOCA0059EN-00 04/2013 EVlink Cluster Cabinet Including EVlink MS Energy Management and EVlink MS Supervision Recommendation Guide 04/2013 DOCA0059EN-00 www.schneider-electric.com The information

More information

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS FEATURES Robust, durable construction Unique double doors open 180 with minimum projection Light grey colour standard, can be painted to suit décor re quirements

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

Basic Series Accessories Low Voltage Current Transformer Class 1

Basic Series Accessories Low Voltage Current Transformer Class 1 Low Voltage Current Transformer Class 1 Current Transformer Current transformers for direct mounting to bus bars or insulated round conductors. Application: indirect measurement of sinusoidal alternating

More information

Simple and smart power factor correction

Simple and smart power factor correction Simple and smart power factor correction VarSet Low voltage capacitor banks VarSet I 2 Do you need an easy solution to immediately boost your facility s energy efficiency and productivity? Are products

More information

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com Multi 9 TM Catalogue 207 Multistandard protection for OEM schneider-electric.com Green Premium TM Endorsing industry eco-friendly products Schneider Electric s Green Premium ecolabel is committed to offering

More information

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation 86 Customhouse Quay PO Box 165, Wellington 6140 New Zealand Date of publication: 1 November 2016 Issued by: Mark Wogan, Manager Energy Safety WorkSafe New Zealand Electric Vehicle Charging Safety Guidelines

More information

DX³ RCBO 6000 A Phase + Neutral, neutral right side

DX³ RCBO 6000 A Phase + Neutral, neutral right side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1

More information

CP Automatic capacitor bank

CP Automatic capacitor bank CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor

More information

MCset kv Medium voltage equipment

MCset kv Medium voltage equipment Maintenance Guide PE90014 PE90006 MCset 1-2 - 3 17.5 kv Medium voltage equipment Air-insulated switchboards Metal-enclosed switchgear with moving parts PE90007 PE90008 PE90009 PE90007 Maintenance Guide

More information

Offers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants

Offers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants devices Offers This page must be removed before publishing The Schneider Electric residual current devices range comprises various offers (A, B, C, D) so as to be as competitive as possible in each country,

More information

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards Medium Voltage Switchgear Primary Distribution CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka General description Presentation Ormazabal s CPG System includes the CPG.1

More information

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient Medium voltage NEX switchgear Withdrawable circuit breaker Quite simply efficient NEX, a simple and flexible solution NEX is the result of worldwide acquired experience and provides you with a high level

More information

Residual current devices

Residual current devices Residual devices FH00 Plus of range /30 Technical features table /3 Ordering information /34 Technical details /37 DS01 and DS0C Plus of range /38 Technical features table /40 Ordering information DS01

More information

IET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 717 MOBILE OR TRANSPORTABLE UNITS

IET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 717 MOBILE OR TRANSPORTABLE UNITS IET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 717 MOBILE OR TRANSPORTABLE UNITS 717.1 Scope The particular requirements of this section apply to a.c. and d.c. installations for mobile or transportable

More information

Symmetra PX 20 kw. InfrastruXure 208 V. Installation 01/

Symmetra PX 20 kw. InfrastruXure 208 V. Installation 01/ Symmetra PX 20 kw InfrastruXure 208 V Installation 01/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Dim your energy consumption

Dim your energy consumption Dim your energy consumption Less energy and more comfort with new solutions P121220 Dimmer as an energy saver? Lighting makes up 40% of the energy consumption in private homes P121135 2 Energy efficiency

More information

Easy UPS 3S with Internal Batteries

Easy UPS 3S with Internal Batteries Easy UPS 3S with Internal Batteries 10 40 kva 3:3 Installation E3SUPS10KHB, E3SUPS10KHB1, E3SUPS10KHB2, E3SUPS15KHB, E3SUPS15KHB1, E3SUPS15KHB2,E3SUPS20KHB, E3SUPS20KHB1, E3SUPS20KHB2, E3SUPS30KHB, E3SUPS30KHB1,

More information

Technical Journal September 2012

Technical Journal September 2012 Technical Journal September 2012 Earth leakage protection in polluted low voltage network In present day irrespective of the application be it in process industry or in IT industry, Pollution of electrical

More information

ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET

ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Candidate Code No. EIN15 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

Solutions. for large buildings and power plants

Solutions. for large buildings and power plants s for large buildings and power plants Renewable energy from solar panels s for photovoltaic arrays In recent years photovoltaic electricity generation has met the growing demand for energy. There is a

More information

Wiring devices Asfora 2015 catalogue

Wiring devices Asfora 2015 catalogue Wiring devices 05 catalogue Contents Presentation Products with cover frame (white, cream) Switches and push-buttons 6 Socket-outlets 8 Communication outlets 9 Dimmers 0 ccessories Products without cover

More information

Bulletin 193-T1 Bimetallic Overload Relays

Bulletin 193-T1 Bimetallic Overload Relays Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode

More information

NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking)

NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking) NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking) Generation Directorate Medium Generation Operation and Maintenance Department SUNDARIJAL HYDROPOWER PLANT REHABILITATION PROJECT Electricity

More information

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001 CLP POWER HONG KONG LIMITED SUPPLY March 2001 ADVISORY SERVICE Advice concerning matters relating to the supply of electricity may be obtained free of charge from the Company. OTHER COMPANY PUBLICATIONS

More information

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv] BasisBlock MC 1 Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC1-12 MC1-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage

More information

NXPLUS C Single busbar. Maintenance-free for lifetime

NXPLUS C Single busbar. Maintenance-free for lifetime NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage

More information

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U Instruction Manual Supplement for FRN-C2S-2U/4U (7.5 to 20 HP) Compact Inverter 200 V series: FRN0025 to 0060C2S-2U series: FRN0013 to 0030C2S-4U Thank you for purchasing our FRENIC-Mini series of inverters.

More information

8036-A0 Motor Drives Training System (Stand-Alone)

8036-A0 Motor Drives Training System (Stand-Alone) 8036-A0 Motor Drives Training System (Stand-Alone) LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 04/2018 Table of Contents General Description 2 List of Equipment 2 List of Manuals 2 Table of

More information

Symmetra PX kw 208 V. Installation 01/

Symmetra PX kw 208 V. Installation 01/ Symmetra PX 10 40 kw 208 V Installation 01/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred to

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information