1 PLUS PLUS & PRO Installation manual

2 Safety warnings Manual for Maxem Plus and Pro Energy Manager. Publication Date: May 15, 2017 Questions or improvements If you see any errors or defects, if you have ideas about how to improve this manual or the Maxem system, please send an with your feedback to Safety Information Product symbols statements Only to be installed by a certified electrician. Completely follow the instructions given in this manual. Use this device only for the purpose it is designed for, as described in this manual. Maxem works only after online activation. Failure to follow the above warnings can lead to an incorrect Maxem installation. This can lead to over current of the grid connection, damage to installations and charging stations, electric shocks or fire. Install and use this product only after careful reading of the manual. This product is double insulated. Indoor use only. This product is designed for overvoltage category III. This product meets all the requirements set by the EU for Symbols in this document product safety. Product contains electronics. Do not throw it in the household waste. Warning Tip Liability Cohere is not responsible for the installation of Maxem and for any damage arising from not following the installation manual correctly. Nor for damage resulting from typographical errors or misinterpretations of text or images COHERE ENERGY SOLUTIONS B.V. All information in this document is the copyright and intellectual property of Cohere Energy Solutions B.V. Material in this document may not be modified, reproduced or copied, in part or in whole, without the explicit written consent of Cohere Energy Solutions B.V. Additional information is available upon request. Maxem is a registered trademark of Cohere Energy Solutions B.V. 2 3

3 Index What is Maxem? What is Maxem? 5 Product specifications 6 Installation requirements 8 Fuse settings of charging stations 10 From the main grid panel, Maxem measures the energy use in the house and the energy generation of solar panels. Based on this information, it manages the power between the building and multiple charging stations. This way there is no risk of over current on the grid connection and it is easier to utilize the produced solar power. Also more charging stations can be installed than normal. Installation Steps 01 - Mounting on the wall Installing kwh-meter for main grid connection 12 Option Installing kwh-meter Maxem Plus (<80A) 12 Solar panels Maxem measures the power generation of solar panels. Maxem is able to control the charging stations based on this generation. This way you make 100% use of your own renewable energy! Option Installing kwh-meter Maxem Pro (>80A) Installing kwh-meter for solar panels Connecting charging stations Option Connecting KEBA charging stations 18 Option Connecting ICU charging stations 20 Option Connecting EV-Box charging stations 21 Maxem Maxem optimizes energy flows in the building. More charging stations Safely install more charging stations athigher power without the risk of overloading the grid connection. Maxem controls the charge capacity of each charging station per second. Flexible expansion Install up to 250 charging stations to let the charge park grow over time with the increase electric vehicles. Maxem is easily expanded Connecting Maxem Configuration and commissioning 24 Appendix 1 - Troubleshooting 27 Appendix 2 - Configuring 65A kwh-meter 29 Appendix 3 - Crimping RJ connectors 30 Grid Maxem optimizes the power consumption of the main grid connection to prevent over current. This way you can save significantly on an expensive grid upgrade. EU Declaration of Conformity

4 O.OFF O.OFF O.OFF O.OFF 01 Product - Voorbereidingen specifications vooraf Content of the box Specifications 1x Maxem including mounting plate 1x Power cable (1m) 1x Network cable (1m) 1x RS485 cable (1m) Dimensions Weight 184 mm (L) x 167 mm (W) x 55 mm (H) 700g Working temperature 10 C to 35 C Storage temperature 0 C to 60 C Maximal humidity 80% Protection class Seal Operational level II (double insulated) IP20 0 to 2,000 m 4x Screws 3x20 2x RJ10 4P4C connector EMC EN (2013), EN , Safety EN (2010), EN (2010) kwh-meter for Maxem Plus kwh-meter for Maxem Pro Immunity EN (2013) Overvoltage category 300V/CAT III Input power V. 50/60Hz. Maximum 2,75W 1x Direct kwh-meter 3-phase 80A 1x Indirect kwh-meter 3-phase 3x Split-core current transformer 250A, 500A of 1000A Input/output ports and LED indicators OK SET OK SET 1x 10A Circuit breaker P1 RS1 RS2 CT1 CT2 CT3 Optional Solar kwh-meter Optional Ethernet switch P1 port RS485 port 2 Current transformers solar panels RS485 port 1 Current transformers grid connection Free power measurement port 1x Solar kwh-meter (<65) 1x RS485 cable (1m) 1x Ethernet switch with power supply 1x Network cable OK SET 1x RS485 splitter Ethernet port to Internet Router Ethernet port to charging stations Power supply 6 7

5 Installation - Voorbereidingen requirements vooraf Wired Internet connection Necessary tools Maxem must be connected to a wired Internet connection. The following is needed: Modem or router connected to Internet. A DHCP connection from the network to Maxem. Maxem should be able to do DNS requests. Maxem may also be placed in a DMZ (demilitarized zone) on a separate VLAN. Outbound data traffic must be possible over ports 80, 443, 1194 t/m 1200 and Environmental Requirements Free space for Maxem with connected wiring at the bottom. Free Schuko 230V socket to power Maxem or free space to place a new one. Free Ethernet port for Internet connected modem or router. An UTP cable must be pulled (or already be available) from Maxem to the charging station. Maxem Plus: Free space in grid panel for kwh-meter: 7 modules / 123 mm on DIN-rail. Maxem Pro: Free space in grid panel for kwhmeter: 4 modules / 76 mm on DIN-rail. Free space in grid panel for 10A circuit breaker: 4 modules / 76 mm on DIN-rail. For Ethernet connected charging stations: Free space for ethernet switch. Free space for wall socket for power supply of ethernet switch ,50mm 20mm 184mm 20mm 20mm 70mm 167mm Maxem Phillips screwdriver, size small. Slotted screwdriver, size mini < 3mm. Slotted screwdriver size large. RJ45 (8P8C) crimper. RJ10 (4P4C) crimper. Cable Tester for UTP cables. Internet connected smartphone, tablet or laptop. Necessary materials A correct circuit breaker or earth leakage circuit breaker with proper safety fuse value. See p. 10 to determine the fuse settings. Schuko sockets for 230V power supply Maxem (if not already available). UTP (CAT5 or CAT6) data cable for connecting charging stations to Maxem. RJ45 (8P8C) connectors for UTP cable. Cable end sleeves for UTP cores (only for Tesla Wall Connector or EV-Box). With Maxem Plus/Pro compatible charging stations KEBA P20/P30 C-series ICU EVe* ICU EVe mini* EV-Box Home** (G3 controller) EV-Box Business** (G3 controller) *ICU charging stations have to be ordered Maxem Ready. **Compatibility of Maxem with multiple EV-Boxes is still in development. Check the Maxem website for the latest overview of compatible charging stations. 8 9

6 01 Fuse - Voorbereidingen setting of charging vooraf stations 01 - Mounting on the wall Maxem protects against over current Maxem is a control system that regulates the load of the charging station. Maxem offers an intelligent layer of protection on top of the circuit breakers. This is done in the following way: When an over current is measured on the main grid connection, the power of the charging stations is immediately adjusted downwards. When the over current is too high, Maxem is able to pause one or more charging stations until more capacity is available again. A. Mount Maxem on a clean, moisture-free wall. Use the supplied mounting plate and screws for this. Take into account sufficient space around Maxem. Therefore it is possible to fuse the charging stations at a higher rate than normal. All charging stations can be fused at their maximum power capacity, but a fuse of a single charging station may never be higher than the capacity of the main grid connection. Points of attention to install future proof If you wish to make the charging system future proof, then take the following attention points into account: According to the Mode 3 protocol of the IEC62196 electric vehicles need at least 6A to charge Note that vehicles with a Renault Chameleon charger (Renault Zoe) need at least 13A on 3-phase or 6A on 1-phase to charge. The number of electric vehicles that are able to charge at 32A (1-phase or 3-phase will increase substantially in the coming years. 20mm 20mm 20mm Wiring at the bottom 70mm 10 11

7 OK 02 - Installing kwh-meter grid connection Option Installing kwh-meter Plus (<80A) D. Connect the RS485 cable on the kwh- meter as follows: A. B. Switch off the main circuit breaker in the grid panel. Open the grid panel with the SET Port C: Green wire Port B: White wire Port A: Brown wire C. appropriate tools. Place the kwh-meter on a DIN rail in Connection RS485 cable on kwh-meter RS1 port for kwh-meter the installation cabinet such that it RS1 measures the entire grid connection (immediately after the main circuit OK SET E. Connect the RS485 cable to port RS1 on Maxem. breaker). Connect the power cables according to the wiring diagram below. F. Set the address of the kwh meter to 100. This allows Maxem to configure itself automatically. Do not forget to set the correct address to the kwh meter. Maxem will not work properly without correct configuration of the kwh meter. O.OFF O.OFF O.OFF O.OFF Location of the addressing function in the menu structure on the kwh-meter. Current flow main grid connection RS485 RS485 Address 100 Navigation through the ABB A43 / A44 kwh-meter menu Go to menu. Numbered connection points on kwh-meter Scroll through the menu or set value higher or lower. Press to enter a menu item or to accept an adjustment. Press to adjust a setting. Wiring diagram direct kwh-meter in a TN grid with neutral If you see this icon in the kwh meter display, there is an active data connection with Maxem

8 OK Option Installing kwh-meter Pro (>80A) A. Place the kwh meter on a DIN rail in the grid panel SET Ensure that the current transformers are connected in the right direction and to the correct phases on the kwh-meter. Incorrect installation can lead to over current on the grid connection. B. Protect the indirect kwh-meter with C. the included 10A circuit breaker. Connect the split-core current transformers such that they measure the entire grid connection (immediately after the main circuit breaker). Note that the current direction follows the arrow on the split-core current transformer. Grid panel P2 P1 Grid connection F. Set the address of the kwh-meter to 100. This allows Maxem to configure itself automatically. Do not forget to set the correct address to the kwh meter. Maxem will not work properly without correct configuration of the kwh meter. D. Click the split-core current transformers around the power Location of the addressing function in the menu structure on the kwh-meter. cables. Use the included tie-wrap to secure the current transformer tightly to the power cable. 100 Make sure that there is no dirt or grease on the inside of the closure of the split-core current transformer. This may result in inaccuracy in the measurement and thereby over current on the main grid connection. F. Configure the primary and secondary amperage of the current transformers in the kwh-meter. These values can be Primary value 500/5A Secondary value found on the current transformers. E. Connect the split-core current transformers and the power supply of the 10A circuit breaker to the kwh meter according to the diagram below. Location of primary and secondary values in menu structure. Current transformer Numbered connection points on kwh-meter Pri Sec Primary amperage Secondary amperage Configure primary amperage* Configure secondary amperage* Wiring diagram of indirect kwh-meter in a TN grid with neutral

9 03 - Installing kwh-meter for solar panels Navigation through the ABB B23 / B24 kwh-meter menu Press for 2 seconds to access the main or go up in the menu. Scroll through the menu or set value higher or lower. Press to enter a menu item or to accept an adjustment. A. B. C. Place the kwh-meter on a DIN-rail in the grid panel. Connect it such that it masures the output of the solar inverter. Connect the RS485 cable on the kwh-meter as follows: Port C: Green wire Port B: White wire Port A: Brown wire Press to adjust a setting. Solar panels F. If you see this icon in the kwh meter display, there is an active data connection with Maxem. Connect the RS485 cable on the kwh-meter as follows: Current direction OK SET Connection RS485 cable on kwh-meter Port C: Green wire Port B: White wire Port A: Brown wire Grid panel D. Connect the included RS485 splitter to the RS1 port on Connection RS485 cable on kwh-meter E. Maxem. Connect the kwh-meters for both the main grid connection and solar panels to the RS485 splitter. RS1 port for RS485 splitter OK SET F. Set the address of the kwh-meter to 001. This allows Maxem to configure itself. See appendix 2 on how to RS1 configure the address. E. Connect the RS485 cable to port RS1 on Maxem. RS1 port for kwh-meter RS

10 04 - Connecting charging stations Option Connecting KEBA charging stations DSW1 - Power (block above) A. Follow the installation instructions of the charging stations. These can DSW2 - Addressing (block below) be found in the installation manual of the charging station. B. Install a circuit breaker or earth leakage circuit breaker at the maximal power available. See page 10. C. Connect the power supply of the charging stations so that the load of L1, L2 and L3 is evenly distributed. The table below shows the standard distribution. D. Route a suitable UTP (CAT5 or CAT6) cable from all charging stations to Maxem and E. attach RJ45 connectors on both sides of the cable. Connect the UTP cables to the Ethernet Switch and connect one of ports on the Data activity on ETH poort KEBA P20 of P30 UTP-cable with RJ45 connectors Data activity on ETH poort Maxem Ethernet Switch ETH port on Maxem. F. Set DSW 1.3 to ON. Smart charging will be activated. Maxem Charging station Phase distribution G. Set DIP switches on DSW1 to the maximum available power. Ethernet switch # 1 L1 L2 L3 # 2 L3 L1 L2 # 3 L2 L3 L1 H. Switch the power supply of the KEBA P20/P30 off (the DIP switch settings will only be activated after a charging station reset). # 4 L1 L2 L3 # 5 L3 L1 L2 # 6 L2 L3 L1 DIP switch settings for setting the maximum power. # 7 L1 L2 L3 KEBA 1 KEBA 2 KEBA n Maxem and KEBA P20 / P30s with a switch connected. # n Standard phase distribution Maxem 10A 20A 13A 25A DSW 1.6 Off It is advisable to test the network cable with the help of a cable tester. DSW 1.7 Off 16A 32A DSW 1.8 Off See the KEBA P20 / P30 installation manual for more information

11 Option Connecting ICU charging stations Option Connecting EV-Box charging stations A. Follow the installation instructions of the charging stations. These can be found in the installation manual of the charging station. B. Install a circuit breaker or earth leakage circuit breaker at the maximal power available. See page 10. C. Connect the power supply of the charging stations so that the load of L1, L2 and L3 is evenly distributed. The table below shows the standard distribution. D. Route a suitable UTP (CAT5 or CAT6) cable from all charging stations to Maxem and attach RJ45 connectors on both sides of the cable. E. Connect the UTP cables to the Ethernet Switch and connect one of ports on the Ethernet Switch ETH port on Maxem. Charging Phase Maxem station distribution # 1 L1 L2 L3 # 2 L3 L1 L2 Ethernet switch # 3 L2 L3 L1 # 4 L1 L2 L3 # 5 L3 L1 L2 # 6 L2 L3 L1 # 7 L1 L2 L3 ICU 1 ICU 2 ICU n # n Maxem and ICU charging stations connected with a switch. Standard phase distribution Maxem A. Follow the installation instructions of the charging stations. Connect the EV-Box Satellites to the Hub in a hub-satellite configuration. The instructions for this can be found in the installation manual of the charging station. B. Install a circuit breaker or earth leakage circuit breaker at the maximal power available. See page 10. C. Connect the power supply of the charging stations so that the load of L1, L2 and L3 is evenly distributed. The table below shows the standard distribution. D. Route a suitable UTP (CAT5 or CAT6) cable from the EV-Box hub to Maxem. (To prevent electromagnetic interference with distances greater than 25m, it is recommended to use FTP CAT6 cable. Maximum distance is 50m). Charging Phase Maxem Hub Satellite 1 Satellite n station distribution # 1 L1 L2 L3 # 2 L3 L1 L2 # 3 L2 L3 L1 # 4 L1 L2 L3 # 5 L3 L1 L2 # 6 L2 L3 L1 Maxem and EV-Boxes in a Hub - Satellite configuration # 7 L1 L2 L3 # n Standard phase distribution Maxem It is advisable to test the network cable with the help of a cable tester. ETH port ICU UTP-cable with RJ45 connectors Data activity on ETH port Maxem The charging station firmware may need to be updated. This can be done via ICU Connect. ICU can assist you with this

12 05 - Connecting Maxem A. Check if all parts are connected to Maxem. 12V/DC AB GND B. Connect Maxem to the Internet-connected modem or router with the included network cable. Wires for strain relief Lip on top RS2 port for EV-Box Hub Pin 2 Pin 1 Diagram of the controller of the EV-Box Hub connected to Maxem. RS2 Ethernet port to Internet Router E. Crimp the included RJ10 4P4C connector to the data cable on the Maxem side: Connect wire 1 (orange-white) to Pin 1. Connect wire 2 (orange) to Pin 2. C. Connect Maxem to a wall socket in the meter cabinet with the supplied 230V power Connect two other wires as a strain relief. cable. F. Connect the RJ10 4P4C connector to the RS2 port on Maxem. G. Connect the 2 wires of the data cable to the green 4-pole Phoenix connector and connect this connector to the designated port on the EV-Box modem: Connect wire 1 (orange-white) to Port A. Connect wire 2 (orange) to Port B. The remaining ports do not need to be connected. Power supply 22 23

13 P1 RS1 RS2 CT1 CT2 CT Configuration and commissioning In case of unsuccessful installations Maxem is unable to send a power limiting value to the charging stations, resulting in OVERLOAD OF THE GRID CONNECTION. Therefore, make sure that the installation has been successful! D. Fill out the configuration of the installation in the table below. Configuration installation Main grid connection Fuse: A A. B. Turn on the charging stations or reboot them by cutting the power supply for at least 30 seconds. Wait at least 1 minute for the charging stations to boot. Connect the 230V power to Maxem. Sub grid panel Present*: yes / no Fuse: A Solar panels Present*: yes / no Fuse: A Charging station brand EV-Box ICU KEBA Number of charge sockets C. Maxem has to be configured via the online configuration tool. Go to the website E. Complete the configuration of all connected charging stations in the table below. and follow the configuration steps: F. Provide the user with the manual and the completed configuration tables. install.maxem.io # Serial number Number of Power per Fuse Phase distribution** charging station sockets* socket Phases Amps L1 L2 L3 LED indications on Maxem 1 1 / 2 A 1f / 3f A Charger Charger Charger 2 1 / 2 A 1f / 3f A LED indication Meaning 3 1 / 2 A 1f / 3f A Central LED indicator Burns continuously Maxem works correctly. 4 1 / 2 A 1f / 3f A 5 1 / 2 A 1f / 3f A Flashes 4x Maxem has no Internet connection. 6 1 / 2 A 1f / 3f A Flashes 2x Maxem returns to factory settings. 7 1 / 2 A 1f / 3f A Flashes continuously Maxem is booting. 8 1 / 2 A 1f / 3f A 9 1 / 2 A 1f / 3f A 10 1 / 2 A 1f / 3f A LED indicators input/output ports LED indication Meaning Status communication LED is off Nothing is configured on Maxem - LED is green Communication is OK. LED is red Communication is expected, but is not detected. LED flashes green/red Communication detected, but is different than expected / 2 A 1f / 3f A 12 1 / 2 A 1f / 3f A 13 1 / 2 A 1f / 3f A 14 1 / 2 A 1f / 3f A 15 1 / 2 A 1f / 3f A 16 1 / 2 A 1f / 3f A 17 1 / 2 A 1f / 3f A 18 1 / 2 A 1f / 3f A 19 1 / 2 A 1f / 3f A If you have problems with commissioning, please contact: *Strikethrough what does not apply **Specify how the each phase is connected to each charging station. Enter the appropriate phase of the main grid connection in each of the boxes

14 Appendix 1 - Troubleshooting # Serial number Number of Power per Fuse Phase distribution** charging station sockets* socket Phases Amps L1 L2 L / 2 A 1f / 3f A 21 1 / 2 A 1f / 3f A 22 1 / 2 A 1f / 3f A 23 1 / 2 A 1f / 3f A 24 1 / 2 A 1f / 3f A 25 1 / 2 A 1f / 3f A 26 1 / 2 A 1f / 3f A 27 1 / 2 A 1f / 3f A 28 1 / 2 A 1f / 3f A 29 1 / 2 A 1f / 3f A 30 1 / 2 A 1f / 3f A 31 1 / 2 A 1f / 3f A 32 1 / 2 A 1f / 3f A 33 1 / 2 A 1f / 3f A 34 1 / 2 A 1f / 3f A 35 1 / 2 A 1f / 3f A 36 1 / 2 A 1f / 3f A 37 1 / 2 A 1f / 3f A 38 1 / 2 A 1f / 3f A 39 1 / 2 A 1f / 3f A 40 1 / 2 A 1f / 3f A 41 1 / 2 A 1f / 3f A 42 1 / 2 A 1f / 3f A 43 1 / 2 A 1f / 3f A 44 1 / 2 A 1f / 3f A 45 1 / 2 A 1f / 3f A 46 1 / 2 A 1f / 3f A 47 1 / 2 A 1f / 3f A 48 1 / 2 A 1f / 3f A 49 1 / 2 A 1f / 3f A 50 1 / 2 A 1f / 3f A Charger Charger Charger Maxem does not connect to the online back end Verify that Maxem s network connection is active. If there is an active data connection, an orange LED flashes on the Maxem LAN port. Verify that there is an Internet connection on the connected router. Verify that the UTP cable is properly connected using a cable tester. Make sure Maxem is able to make a DHCP connection to the network. Make sure Maxem is able make DNS requests over the network. Restart Maxem by turning it off and on. Any problems with IP addressing can be solved this way. The charging station is not detected or not detected correctly RS485 connected charging stations: Check whether the RJ10 (4P4C) connector is securely plugged in. See Appendix 3 how to crimp RJ connectors. Ethernet-connected charging stations: Verify that there is an active data connection with the charging station (visible by a green and orange LED). If not, check whether the RJ45 connectors are properly crimped. Restart the charging station by turing it off and on again. Make sure the charging station runs firmware which is compatible with Maxem. The car charges too slow or too fast Maxem software is not configured. Go to the website install.maxem.io to run the configuration tool. Check what the maximum charging power of the car is. For example, the Tesla Model S requires a dual charger to charge on 3x24A. A Model S with a single charger charges up to 3x16A. For KEBA charging stations: Check whether the DIP switches are set correctly. The fuse for the charging station is set too low or too high in the configuration of Maxem. A Cohere employee can help you to customize this. *Strikethrough what does not apply **Specify how the each phase is connected to each charging station. Enter the appropriate phase of the main grid connection in each of the boxes

15 Appendix 2 - Configuring 65A kwh-meter One or more cars do not start charging Restart the charging station (power off the MCB, wait 10 seconds, then power up the MCB again). Make sure the charging cable is not connected to the car. EV-Box The charging station is running on out dated firmware. Contact EV-Box for a firmware update. Restart the charging station after the update. Maxem set a power value outside of the the charging stations range. Make sure the EV-Box is set to at minimum 6A and maximum to the fuse of the charging station. ICU The charging station is running on out dated firmware. Contact ICU Alfen for a firmware update. Restart the charging station after the update. There is an authorization issue so that the charging station does not receive permission to start a charging session. Contact ICU Alfen to configure this online. KEBA The charging station is not set smart charge ready. Make sure DIP switch 1.3 is turned on. Tesla Wall The charging station is not set to Slave (F mode). The red LED Connector indicator flashes 4x on the Wall Connector. Set it to Slave (F Mode). Maxem is able to measure different devices using an external MID certified kwh meter. In order for the communication to function correctly, the kwh-meter must be set to the corresponding address. Here s how to do this: Location of the addressing function in the menu structure. Standard addressing on kwh-meter Number of devices Type of device Device Example addresses Node Address Node Address Main grid connection 100 Main grid connection 100 Solar 001 Solar #1 001 Charging station 002 Solar #2 011 Heat pump 004 Charging station #1 002 Charging station #2 012 Heat pump #1 004 Heat pump #2 014 The values in the web portal are not logical The kwh-meter(s) have to be set correctly. If the address is not set correctly, the Maxem install wizard will not recognize the kwh-meter. If the address is set at 16 and cannot be changed, this indicates that the protocol settings are incorrect. Make sure the kwh-meter is set as follows: Protocol: Modbus. Parity: Even. Baud rate: The kwh-meter is not connected correctly to the power supply. This can also be seen on the display of the kwh-meter where the kwh value does not go up. Connect the power supply to the kwh-meter correctly. The phase distribution of the power supply of the charging stations is not correctly configured on Maxem s. Check the phase distribution and communicate this to Cohere. Navigation through the ABB B23 / B24 kwh-meter menu Press for 2 seconds to access the main or go up in the menu. Scroll through the menu or set value higher or lower. Press to enter a menu item or to accept an adjustment. Press to adjust a setting. If you see this icon in the kwh meter display, there is an active data connection with Maxem

16 2 Troubleshooting Appendix 3 - Crimping RJ-connectors Troubleshooting EU Declaration of Conformity Required tools and material We, Crimping pliers (suitable for RJ10 and / or RJ45 plugs) Scissors or cutters Sharp (Stanley) knife RJ10 or RJ45 plugs Steps A. Strip approximately 3 cm of the outer cover with a sharp (Stanley) knife. The individual wires should not be damaged. B. Cut the wires in a straight line with a pair of pliers in order to have them all with the same length. C. Insert the wires into the RJ10 or RJ45 connector. Make sure that the wires are placed in the correct order. For the RJ10 connector it is recommended to place 2 additional wires for strain relief. Cohere Energy Solutions B.V. Willem de Zwijgerlaan RD Amsterdam, Nederland following the provision of the following EC Directives: 2006/95/EC The Low Voltage Directive 2004/108/EEC The Electromagnetic Compatibility Directive Hereby declare that the product: Maxem Energy Manager 4.0 is in conformity with the applicable requirements of the following documents: Emissions EN (2013) EN (2006) + A1 (2009) + A2 (2009) EN (2008) D. E. Make sure that the wires are inserted deep enough into the connector in order to have them firmly fixed. Place the connector with the inserted cable into the pliers. Clench it in order to have the wires secured and exposed. It may be necessary to clench the pliers firmly two times or more. Double-check that all cores are fully inserted. If this is not done correctly, the cable will not work properly. Immunity EN (2013) Safety EN (2010), EN (2010) EN Signee Date Place Signature Connection diagram Jan Willem Heinen CEO 1 August 2016 Amsterdam 8P8C (RJ45) 4P4C (RJ10) Lip on top side Lip on top side Wires for strain relief 30 31

17 Willem de Zwijgerlaan RD Amsterdam The Netherlands +31 (0)

ENERGY MANAGER. Installation Manual

ENERGY MANAGER. Installation Manual ENERGY MANAGER Installation Manual Safety Information Manual for Maxem Home Energy Manager. Publication Date: November 1, 2016 Questions or improvements If you see any errors or defects, if you have ideas

More information

PLUS & PRO. Installation manual Maxem 5 English

PLUS & PRO. Installation manual Maxem 5 English PLUS & PRO Installation manual Maxem 5 nglish 1 Safety warnings Manual for Maxem Plus & Pro Hardwareversion: 5 Publication date: May 1, 2018 Check for the most recent information on www.maxem.io Safety

More information

Installing a Programmed Fronius SCERT in a Managed AC Coupled system

Installing a Programmed Fronius SCERT in a Managed AC Coupled system Installing a Programmed Fronius SCERT in INTRODUCTION This document is included with Fronius SCERT PV Inverters that have been programmed. It applies only to units that have been programmed and are ready

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

2 x type 2 socket, 1-phase, max. 1x32A input, RCD type A, 6mA detection, Display

2 x type 2 socket, 1-phase, max. 1x32A input, RCD type A, 6mA detection, Display General Model name Product no. 2 x type 2 socket, 1-phase, max. 1x32A input, RCD type A, 6mA detection, Display 904461011 2 x type 2 socket, 1-phase, max. 2x32A input, RCD type A, 6mA detection, Display

More information

Getting started with

Getting started with PART NO. CMA113 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption & Solar PV generation monitoring single phase, for homes fitted

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

StorEdge Wiring Guide & On Site Checklist - Europe, Australia & South Africa

StorEdge Wiring Guide & On Site Checklist - Europe, Australia & South Africa StorEdge Wiring Guide & On Site Checklist - Europe, Australia & South Africa This document contains a battery wiring guide and on site checklist with steps for post-installation verification of a StorEdge

More information

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel: Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation

More information

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES Installation and Programming Manual Part: Building Network Interface Card 4100-6047 Product: 4100ES Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS- Follow the instructions in this installation

More information

USERS MANUAL MCD REMOTE OPERATOR

USERS MANUAL MCD REMOTE OPERATOR USERS MANUAL MCD REMOTE OPERATOR Order Code: 175G9004, 175G3061 Contents Contents Introduction...2 Important User Information...2 General Description...2 Symbols Used in this Manual...2 Installation...3

More information

My Reserve 500 Install Guide

My Reserve 500 Install Guide My Reserve 500 Install Guide System Overview Diagram Warnings Disclaimer of Liability and Warranty: This guide does not replace the Owner s Guide and Installation Instructions supplied with the components.

More information

c-go 24V/6A 24V/8A 24V/12A

c-go 24V/6A 24V/8A 24V/12A c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...

More information

Relay Retrofit Program Cutting Tool Safety Guide

Relay Retrofit Program Cutting Tool Safety Guide Relay Retrofit Program Cutting Tool Safety Guide Copyright This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted

More information

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems LMC 301 controller For reliable control of small, large or multi-system-type lubrication systems LMC 301-controlled systems can be configured to verify that lubricant is dispensed LMC 301 controller with

More information

SNMP dedicated to ORVALDI Solar Infini

SNMP dedicated to ORVALDI Solar Infini SNMP dedicated to ORVALDI Solar Infini User s Manual Management Software for Solar Inverter Table of Contents 1. 2. 3. Overview...1 1.1 Introduction...1 1.2 Features...1 1.3 Overlook...1 1.4 Installation

More information

Fuse state indicator MEg72. User manual

Fuse state indicator MEg72. User manual Fuse state indicator MEg72 User manual MEg Měřící Energetické paráty, a.s. 664 31 Česká 390 Czech Republic Fuse state indicator MEg72 User manual Fuse state indicator MEg72 INTRODUCTION The fuse state

More information

For reliable control of small, large or multi-system-type lubrication systems

For reliable control of small, large or multi-system-type lubrication systems LMC 301 controller For reliable control of small, large or multi-system-type lubrication systems Models 86500, 86501 Models 86502, 86503 Designed for use with pumps that have no internal controller, the

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

SolarEdge. StorEdge Solution Applications. Connection and Configuration Guide. For North America Version 1.0

SolarEdge. StorEdge Solution Applications. Connection and Configuration Guide. For North America Version 1.0 SolarEdge StorEdge Solution Applications Connection and Configuration uide For orth America Version 1.0 StorEdge TM Solution Applications Connection and Configuration (orth America) Contents Introduction

More information

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information. Datasheet Compact Heat Meters Technical Overview Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount

More information

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...

More information

Bosch Smart Home. Door/Window Contact Instruction Manual

Bosch Smart Home. Door/Window Contact Instruction Manual Bosch Smart Home Door/Window Contact Instruction Manual Start making your home smart! Please be sure to install the Bosch Smart Home Controller first. Please ensure that you have a Bosch Smart Home Controller

More information

SP PRO KACO Managed AC Coupling

SP PRO KACO Managed AC Coupling SP PRO KACO Managed AC Coupling Introduction The SP PRO KACO Managed AC Coupling provides a method of linking the KACO Powador xx00 and Powador xx02 series grid tie inverters to the SP PRO via the AC Load

More information

EVlink Parking EVF1 - EVW1

EVlink Parking EVF1 - EVW1 EVlink Parking EVF1 - EVW1 Parking Charging Stations User Manual 07/2013 EVF1ppppppp EVW1ppppppp DOCA0063EN-01 www.schneider-electric.com This document contains general descriptions and/or general technical

More information

Mass Sine 24/10000 Mass Sine 24/15000

Mass Sine 24/10000 Mass Sine 24/15000 USERS- AND INSTALLATION MANUAL Mass Sine 24/10000 Mass Sine 24/15000 Modular high power inverter system MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands ENGLISH: PAGE 1 Tel.: +31-20-342

More information

ILED Aquarius Illuminated Windsock. User Manual

ILED Aquarius Illuminated Windsock. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 3.1 The light fitting has a type plate:... 4 3.2 The junction box has a type plate:... 5 4. Product Description...

More information

INSTALLATION USER MANUAL

INSTALLATION USER MANUAL INSTALLATION & USER MANUAL DYNAMIC LOAD MANAGEMENT -PREMIUM- This document is copyrighted, 2016 by Circontrol, S.A. All rights are reserved. Circontrol, S.A. reserves the right to make improvements to

More information

ET9500 BEMS Interface Box Configuration Guide

ET9500 BEMS Interface Box Configuration Guide ET9500 BEMS Interface Box Configuration Guide APPLICABILITY & EFFECTIVITY Explains how to install and configure ET9500 BEMS Interface Box. The instructions are effective for the above as of August, 2015

More information

System Monitoring SCHOOLMETERBOX AU

System Monitoring SCHOOLMETERBOX AU System Monitoring SCHOOLMETERBOX AU Installation Guide SMETER-IEN084710 98-00013210 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this Manual..............................

More information

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual Copyright Copyright 2014 Eppendorf AG, Germany. No part of this publication may be reproduced without the prior permission

More information

Installation Manual. PowerRouter Solar Battery self-use. Version

Installation Manual. PowerRouter Solar Battery self-use. Version Installation Manual PowerRouter Solar Battery self-use Version 011212 Standby Drill template the PowerRouter Standby Standby Drill template the PowerRouter Standby Standby Standby Standby Standby Standby

More information

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A Manual EN Appendix Lynx Ion BMS 400A / 1000A 1. SAFETY INSTRUCTIONS 1.1 In general Please read the documentation supplied with this product first, so that you are familiar with the safety signs en directions

More information

DC Master 24/ A

DC Master 24/ A USERS MANUAL DC Master 24/12 50-60A DC-DC converter MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH Copyright 2015

More information

IQL Helios Area-/Streetlight. User Manual

IQL Helios Area-/Streetlight. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description... 5 5. Specifications... 6 5.1 General... 6 5.2 Dimensions... 6 6. Installation...

More information

CHAdeMO ADAPTER OWNER S MANUAL

CHAdeMO ADAPTER OWNER S MANUAL CHAdeMO ADAPTER OWNER S MANUAL COMMUNICATIONS REGULATIONS RADIO AND TELEVISION INTERFERENCE The equipment described in this manual can generate and radiate radio-frequency energy. If it is not installed

More information

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN Accessories for Stand-alone inverter SUNNY ISLAND GENMAN Technical Description GenMan-TEN082730 98-2001230 Version 3.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this manual..............................

More information

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor. sales@jumo.co.uk info.us@jumo.net Page 1/8 JUMO thermocor Portable measuring system for AMS2750 and CQI-9 Brief description The JUMO thermocor is a high-precision documenting test device with 12 analog

More information

StorEdge TM Solution Applications with the StorEdge Interface and LG Chem Batteries Connection and Configuration (Europe, APAC, South Africa)

StorEdge TM Solution Applications with the StorEdge Interface and LG Chem Batteries Connection and Configuration (Europe, APAC, South Africa) StorEdge TM Solution Applications with the StorEdge Interface and LG Chem Batteries Connection and Configuration (Europe, APAC, South Africa) Revision History Version 2.1 (December 2018) Added the requirement

More information

REVISION HISTORY REVISION HISTORY

REVISION HISTORY REVISION HISTORY FILTER CONTROLLER REVISION HISTORY Filter Flush Controller forms part of the Netafim range of filtration controllers all designed to make filteration more reliable and economical.. Contact any of the Netafim

More information

BLUE 3 INSTALLATION GUIDE

BLUE 3 INSTALLATION GUIDE BLUE 3 INSTALLATION GUIDE CATCH Power BLUE 3 Installation manual - Page 1 IMPORTANT This product must be installed by a licensed electrician. This product must be installed according to the AS3000 Australian

More information

BMW i. Freude am Fahren. BMW i Wallbox Plus. Owner's manual

BMW i. Freude am Fahren. BMW i Wallbox Plus. Owner's manual BMW i Freude am Fahren BMW i Wallbox Plus Owner's manual BMW i Wallbox Plus Owner's manual 5 EN BMW i Wallbox Plus Owner's manual Contents INFORMATION 10 Safety information 10 Intended use 11 About this

More information

Phoenix Inverter

Phoenix Inverter Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC

More information

StorEdge TM Solution Applications with the StorEdge Interface and LG Chem Batteries Connection and Configuration (Europe, APAC, South Africa)

StorEdge TM Solution Applications with the StorEdge Interface and LG Chem Batteries Connection and Configuration (Europe, APAC, South Africa) December 2017 StorEdge TM Solution Applications with the StorEdge Interface and LG Chem Batteries Connection and Configuration (Europe, APAC, South Africa) Revision History Version 2.0 removed Tesla batteries,

More information

Technical Specification SENTINEL PRO

Technical Specification SENTINEL PRO Technical Specification SENTINEL PRO Contents 1 GENERAL DESCRIPTION... 3 1.1 Main features of the UPS unit... 4 1.2 Standard Versions... 4 1.3 ER Versions for extended autonomy... 4 2 SENTINEL PRO SERIES

More information

SP PRO ABB Managed AC Coupling

SP PRO ABB Managed AC Coupling SP PRO ABB Managed AC Coupling Introduction The SP PRO ABB Managed AC Coupling provides a method of linking the ABB PVI-3.0/3.6/4.2- TL-OUTD and ABB PVI-5000/6000-TL-OUTD string inverters to the SP PRO

More information

GPRS UTP/LAN. Cable gland, range for cable thicknesses 14mm till 25,5mm

GPRS UTP/LAN. Cable gland, range for cable thicknesses 14mm till 25,5mm General Model name Part no. 1 x type 1 fixed cable 5 m, 1-phase, 16A, Plug & Charge 904460001A 1 x type 2 fixed cable 5 m, 1-phase, 16A, Plug & Charge 904460001B 1 x type 1 fixed cable 8 m, 1-phase, 16A,

More information

ThunderION. Static Neutralising System. GB User's Manual 2

ThunderION. Static Neutralising System. GB User's Manual 2 ThunderION SIMCO (Nederland) B.V. Postbus 71 NL-7240 AB Lochem Telefoon +31-(0)573-288333 Telefax +31-(0)573-257319 E-mail general@simco-ion.nl Internet http://www.simco-ion.nl Traderegister Apeldoorn

More information

Lithium Power Supply

Lithium Power Supply Lithium Power Supply User Manual LPS 1200W-60Ah LPS 1500W-100Ah LPS 2500W-100Ah Compact lithium battery based power supply - for easy acces to 230V and 12V energy, everywhere! V1.1 Safety Instructions

More information

INSTRUCTION & INSTALLATION

INSTRUCTION & INSTALLATION INSTRUCTION & INSTALLATION MANUAL MODELS: CCL-eHOME T1C16 CCL-eHOME T1C32 CCL-eHOME T2C16 CCL-eHOME T2C32 WALLBOX ehome SERIES WALLBOX ehome Instruction and Installation manual This document is copyrighted,

More information

ILED Dorado. User Manual

ILED Dorado. User Manual 10NM U-code Medium Intensity Obstruction Light Helideck Status Light 15NM U-code Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description...

More information

AWARE TM VEHICLE INTELLIGENCE INSTALLATION MANUAL

AWARE TM VEHICLE INTELLIGENCE INSTALLATION MANUAL AWARE TM VEHICLE INTELLIGENCE INSTALLATION MANUAL FOR INTERNATIONAL TRUCKS CXT, RXT, MXT, 3200, 4100, 4200, 4300, 4400, 7300, 7400, 7500, 7600, 7700, 8500 and 8600 For Models Built After 2007 MODULES ARE

More information

Relay Retrofit Program for REX 521 Cutting Tool Safety Guide

Relay Retrofit Program for REX 521 Cutting Tool Safety Guide SAFET Y GUIDE Relay Retrofit Program for REX 521 Cutting Tool Safety Guide Copyright This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents

More information

Battery Charger JCB- SCH20LI.2

Battery Charger JCB- SCH20LI.2 Safety and operating manual Battery Charger JCB- SCH20LI.2 ORIGINAL INSTRUCTIONS SAFETY INSTRUCTIONS WARNING: Read all safety warnings and all instructions.failure to follow the warnings and instructions

More information

FLO Home TM X5 Model. Installation Manual FLO Services Inc. All rights reserved.

FLO Home TM X5 Model. Installation Manual FLO Services Inc. All rights reserved. FLO Home TM X5 Model Installation Manual 2016 FLO Services Inc. All rights reserved. v161130:2013 Table of Contents Specifications 3 Safety Instructions 4 Planning your Installation 5 Box Contents 6 Installing

More information

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor. Page 1/8 JUMO thermocor Portable measuring system for AMS2750 and CQI-9 Brief description The JUMO thermocor is a high-precision documenting test device with 12 analog inputs for thermocouples. The use

More information

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Product Overview. Product Identification. Amps One CT Two CTs Three CTs AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Operating instructions

Operating instructions Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future

More information

PowerValue 11/31 T kva

PowerValue 11/31 T kva Technical Datasheet PowerValue 11/31 T 10-20 kva Classification IEC/EN 62040-3 VFI-SS-111 Working mode on-line double conversion Power rating 10-20 kva Paralleling up to 4 units (up to 80 kva) Output power

More information

zelsius Installation and operating manual All that counts EnergyMetering

zelsius Installation and operating manual All that counts EnergyMetering EnergyMetering zelsius Installation and operating manual Electronic compact heat meter M-Bus and 2 inputs/outputs optional Coaxial measuring capsule 2" q p 0.6/1.5/2.5 m³/h All that counts General information

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved. ENGLISH Installation and user manual 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i Copyright 2013 EATON All rights reserved. Service and support: Call your local service representative Certification Standards

More information

OUTSIDE

OUTSIDE TM Eve Mini Manual OUTSIDE 4 4 2 2 3 17 15 12 16 13 14 2 INSIDE Model with charging cable 11 11 5 6 10a 11 10a 9 9 11 7 8 10a 10b 11 11 3 4 Step-by-step Eve Mini installation and commissioning Congratulations

More information

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM MAKING SMART TOWNS, BUILDING SMART COMMUNITIES WHY PANASONIC? RESIDENTIAL STORAGE BATTERY SYSTEM The next evolution in solar energy solutions. Panasonic

More information

Volume CHARGESTORM AB. User Guide CSR100

Volume CHARGESTORM AB. User Guide CSR100 Volume 1 CHARGESTORM AB Charge station modell CSR100 User Guide CSR100 CHARGESTORM AB User Guide CSR100 ã Chargestorm AB Laxholmstorget 3 SE-602 21 Norrköping, Sweden Phone +46 11 333 0002 Fax +46 11 333

More information

THREE-PHASE. FRONIUS ENERGY PACKAGE / The personal storage solution for 24 hours of sun. EFFICIENT FLEXIBLE REVOLUTIONARY

THREE-PHASE. FRONIUS ENERGY PACKAGE / The personal storage solution for 24 hours of sun. EFFICIENT FLEXIBLE REVOLUTIONARY Perfect Welding Solar Energy Perfect Charging ENERGY PACKAGE The personal storage solution for 24 hours of sun. SnapINverter technology Integrated data communication Dynamic Peak Manager Smart Grid Ready

More information

MAXICHARGER. User Manual and Safety Instructions. Version 30/01/2017

MAXICHARGER. User Manual and Safety Instructions. Version 30/01/2017 MAXICHARGER User Manual and Safety Instructions Version 30/01/2017 CONGRATULATIONS! You have just acquired a MAXICHARGER and we thank you! This product is designed and conceived in France, with the collaboration

More information

HMM Series Mechanical Heat Meters

HMM Series Mechanical Heat Meters Mechanical Heat Meters Important: Retain these instructions These instructions shall be used by trained service personnel only If the equipment is used in a manner not specified by these instructions,

More information

Shielded Connector Block for the NI PXI/PXIe-2532/2532B

Shielded Connector Block for the NI PXI/PXIe-2532/2532B INSTALLATION INSTRUCTIONS NI Shielded Connector Block for the NI PXI/PXIe-53/53B This document describes how to install and connect signals to the National Instruments shielded connector block. Use the

More information

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW Thank you for purchasing RS485 card/box. This manual contains instructions and warnings that should be followed during the installation, operating and storage of the card. Please keep this manual for further

More information

Note: If anything is damaged or missing, contact your customer representative immediately.

Note: If anything is damaged or missing, contact your customer representative immediately. Package Contents The package includes: 1 Chassis 1-18 leafs according to the amount ordered 18 - X leaf blanks X = the amount ordered 1 leaf fan module 1 spine fan module 9 spines 1-2 management modules

More information

Installation Guide B-BOX Pro2.5 ~ 10.0

Installation Guide B-BOX Pro2.5 ~ 10.0 Installation Guide B-BOX Pro2.5 ~ 10.0 20170625 Version:2.1 1 / 37 Content Safety... 4 1 Product overview... 5 2 Cabinet terminal introduction... 6 3 Cable outlet of cabinet... 7 4 B-Plus2.5 interface

More information

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF Manuel d installation Installation manual Part. LE05733AA-07/12-01 GF Index 1 Introduction 18 2 Conditions for use 19 3 Installation 20 4 Visual and acoustic warning signals 22 5 ups diagnostic software

More information

AC Level 2 Commercial Charging System. Owner s Manual. Simply Smart.

AC Level 2 Commercial Charging System. Owner s Manual. Simply Smart. AC Level 2 Commercial Charging System Owner s Manual Simply Smart. 2014 by Blink Network, LLC. All rights reserved. No part of the contents of this document may be reproduced or transmitted in any form

More information

Battery Charger JCB-FCH20LI2

Battery Charger JCB-FCH20LI2 Safety and operating manual Battery Charger JCB-FCH20LI2 ORIGINAL INSTRUCTIONS SAFETY INSTRUCTIONS WARNING: Read all safety warnings and all instructions.failure to follow the warnings and instructions

More information

Power Product Specifications

Power Product Specifications Power Product Specifications Boost Power > Boost s ingenious and versatile design makes it compatible with a whole host of locations, from under tables and seats, to table tops, to between arms. Convenient

More information

i-energy i-micro inverter GT260

i-energy i-micro inverter GT260 i-energy i-micro inverter GT260 This installation guide contains important instructions on safety matters and the installation of the i-energy i-micro inverter GT260. Please read this guide carefully and

More information

PDC PROPELLER DE-ICE CONTROLLER

PDC PROPELLER DE-ICE CONTROLLER PDC PROPELLER DE-ICE CONTROLLER OPERATIONAL & INSTALL MANUAL Updated: 14 October 2016 Copyright 2016 by VR Avionics Inc. All rights reserved. This User and Installation Guide and the information contained

More information

KeContact P20. User manual

KeContact P20. User manual KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially

More information

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

Manual. BlueSolar Grid Inverter 1500 / / / / / 230 Manual EN BlueSolar Grid Inverter 1500 / 230 2000 / 230 2800 / 230 4000 / 230 5000 / 230 Before you start This manual contains important information regarding installation and safe operation of this unit.

More information

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT BT403 A Geno Technology, Inc. (USA) brand name BT-300 Power Supply Cat. No. BT403 1-800-628-7730 1-314-991-6034 info@btlabsystems.com WARNING... 3 SAFETY INFORMATION... 3 ENVIRONMENTAL CONDITIONS... 4

More information

Foreword

Foreword Foreword Content 1. Summary 2. Safety instruction Safety Symbol Indication Attention Static discharge sensitive Electric shock Dangerous Indicate risk of serious injury or death or seriously damage the

More information

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings 1662/1663/1664 FC Electrical Installation Tester Safety Information Go to www.fluke.com to register your Product and find more information. A Warning identifies conditions and procedures that are dangerous

More information

Catalogue. products & services

Catalogue. products & services Catalogue products & services NewMotion Europe s Largest Electric Charging Partner No matter your lifestyle, business, car or budget, we are committed to making electric driving as simple and convenient

More information

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners using Installation Kit KIT-364-CM1 Contents Introduction... 2 Safety first... 2 Making a good crimp...

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000 User Manual V1.1 OptiFlex 1100 / OptiFlex 2000 Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation

More information

Volume CHARGESTORM AB. Charging station model EVA Connected. User Manual Connected

Volume CHARGESTORM AB. Charging station model EVA Connected. User Manual Connected Volume 1 CHARGESTORM AB Charging station model EVA Connected User Manual EVA Connected CHARGESTORM AB User manual EVA Connected Chargestorm AB 2017 Hospitalsgatan 3 SE-602 27 Norrköping, Sverige Phone:

More information

Dispense interface converter NA-8 (RS-485/RS-232 to non-addressable RS-422/RS-485/RS-232 and backwards)

Dispense interface converter NA-8 (RS-485/RS-232 to non-addressable RS-422/RS-485/RS-232 and backwards) Dispense interface converter NA-8 (RS-485/RS-232 to non-addressable RS-422/RS-485/RS-232 and backwards) TECHNICAL GUIDE Review date: 20 January, 2017 Revision number: 1.02 TECHNOTRADE LTD CONTENT REVISION

More information

Charging Hub for Inspire 1 Intelligent Flight Batteries

Charging Hub for Inspire 1 Intelligent Flight Batteries Charging Hub for Inspire 1 Intelligent Flight Batteries User Manual V1.0 2015.6 Disclaimer Thank you for purchasing the Charging Hub (hereinafter referred to as product ). Read this disclaimer carefully

More information

USER MANUAL GEBRUIKSAANWIJZING. Phoenix 12/150 Phoenix 24/150 Phoenix 48/150

USER MANUAL GEBRUIKSAANWIJZING. Phoenix 12/150 Phoenix 24/150 Phoenix 48/150 USER MANUAL GEBRUIKSAANWIJZING Phoenix 12/150 Phoenix 24/150 Phoenix 48/150 Copyrights 1999, 2000 Victron Energie B.V. All Rights Reserved This publication or part thereoff, may not reproduced in any

More information

Application Engineering Europe

Application Engineering Europe Date of last update: Feb-12 Ref: D7.8.4/0112-0212/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS 1/17 1 Introduction CoreSense is an ingredient brand name for

More information

1. Introduction OHY1P kW Hybrid Inverter USER MANUAL V2.0

1. Introduction OHY1P kW Hybrid Inverter USER MANUAL V2.0 1. Introduction OHY1P4805 5kW Hybrid Inverter USER MANUAL V2.0 1. Introduction Table of Contents 1. Introduction... 1 2. Important Safety Warning... 2 3. Unpacking & Overview... 4 4. Installation... 5

More information

In-Place-Inclinometer Installation Manual

In-Place-Inclinometer Installation Manual Geotechnical Instrumentation In-Place-Inclinometer Installation Manual SDI-12/RS485 Digital Network Device Vertical I-P-I Chain Operations Only Last updated Nov 2013 Keynes Controls In-place-inclinometer

More information

80V 300Ah Lithium-ion Battery Pack Data Sheet

80V 300Ah Lithium-ion Battery Pack Data Sheet 80V 300Ah Lithium-ion Battery Pack Data Sheet 80 V, 300 amp-hour capacity, maintenance-free energy storage, IP65 design, fully integrated BMS, integrated fuse and safety relay protection, highly configurable

More information

HQ-INV300WU-12 HQ-INV300WU WATT DC TO AC MODIFIED SINEWAVE INVERTER WITH USB OUTPUT

HQ-INV300WU-12 HQ-INV300WU WATT DC TO AC MODIFIED SINEWAVE INVERTER WITH USB OUTPUT HQ-INV300WU-12 HQ-INV300WU-24 300 WATT DC TO AC MODIFIED SINEWAVE INVERTER WITH USB OUTPUT Useful applications Run notebook computers, radios, also TVs, VCRs, DVD players, lamps, fax, etc. Specifications

More information

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility OFF-GRID PV IVERTERS EssenSolar & Expert series Solution on Unstable or Remote Area without 1kW-5kW FSP Off-Gird Inverters: EssenSolar & Expert series An ideal Off-Grid inverter for households, FSP Off-Grid

More information

Heat Meter Integrator

Heat Meter Integrator Heat Meter Integrator Features Simply operation Integral wall and DIN-rail mounting bracket Pulsed or M-Bus output options Measures heating or cooling and heat/cooling Specification Product Codes Temperature

More information

BMW i. Freude am Fahren. BMW i Wallbox Plus. Instructions for use

BMW i. Freude am Fahren. BMW i Wallbox Plus. Instructions for use BMW i Freude am Fahren BMW i Wallbox Plus Instructions for use 5 EN BMW i Wallbox Plus Instructions for use BMW i Wallbox Plus Instructions for use INFORMATION Safety information Intended use About this

More information

Quick Setup Guide. WARNING! Connect this product to an AC power source whose voltage is within the range specified on the product's nameplate.

Quick Setup Guide. WARNING! Connect this product to an AC power source whose voltage is within the range specified on the product's nameplate. Thank you for purchasing the Raritan PX intelligent power distribution unit (PDU). The intended use of the Raritan PX is distribution of power to information technology equipment such as computers and

More information