1 Cat# DC LED Array Emergency Driver Morris DC LED Array Emergency Driver provides emergency operation of DC LED arrays during loss of AC power. In the event of AC power failure, the will operate 4W, 12W or 20W LED arrays for a minimum of 90 minutes. Features Separate 9.6V, high-temperature nickel-cadmium battery packs for 4W, 12W and 20W operation Operates 12V to 40V LED arrays Switch selectable array current settings from 100 to 700 milliamps, in 50 milliamp increments Maintains constant LED array current during battery discharge for constant brightness Battery pack over-discharge protection Battery pack over-temperature and over-current protection Full battery recharge in 48 hours after complete discharge Charging LED indicator also provides fault codes with single and double blinks Universal input voltage of 120VAC 277VAC UL 924 Recognized component for damp location
2 Cat# DC Inverter GENERAL INSTALLATION INSTRUCTIONS LED EMERGENCY INVERTER IMPORTANT SAFE PRACTICES When using electrical equipment, and this lighting device, basic safety precautions should be followed at all times including, but not limited to, the following: PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY IMPORTANT: An un-switched AC power source of 100VAC to 277VAC is required. CAUTION: AC power must be off before installation. Make sure all electrical connections conform to the National Electrical Code and all applicable local regulations. Do not let wires touch hot surfaces. Do not mount near gas or electric heaters. Battery is rechargeable NiCd and must be recycled or disposed of properly. This device is designed for use in fixtures listed for dry and damp locations. Do not use this emergency driver with accessory equipment other than recommended by manufacturer; failure to follow this may cause an unsafe condition. Servicing should only be performed by qualified service personnel. Do not use this emergency driver for other than intended use. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. IMPORTANT: Indicator (LED light) illuminated indicates battery in charge mode when AC power is applied. It is recommended and required by applicable code to test emergency ballast to ensure proper function of the system; push the test switch for thirty (30) seconds every 30 days to ensure the emergency driver is Functioning as LED light source illuminated. Conduct a ninety minute (90) discharge test one time (1) per year; LED light source should be illuminated for a minimum of ninety minutes (90). ASSEMBLY and FIELD INSTALLATION WIRING: WARNING: AC power must be off before proceeding with assembly or installation of emergency driver. TESTING SYSTEM: The emergency battery requires a charge minimum of one (1) hour before testing the circuit. A full charge requires forty eight (48) hours.
3 WIRING DIAGRAM (TYP) BATTERY Drive load 9.6V AA900mAH 4W (12V,300mA - 40V,100mA) 9.6V C2500mAH 12W (12V,700mA - 40V,300mA) 9.6V D4000mAH 20W (12V, 700mA - 40V,500mA) Neutral Unswitched Line 120/277 VAC White Black White/Black Wall Switch 1 2 White Black DC LED DRIVER GND Red + Blue - Yellow + E1 E10 E2 E7 DC LED Emergency Backup E3 E4 1 2 Brown Brown 3 Wire 3 not on AA Packs Test Switch 9.6 Volt Battery Pack E9 E8 E5 E6 Red Blue/White LED+ LED - Charging/Fault LED 20 Watt Max LED Array LED - LED+ Blue Red/White SAVE THESE INSTRUCTIONS
4 Switch Setting Selection Guidelines for Emergency LED Driver This LED Emergency Driver has a field selectable current setting from 100mA to 700mA adjustable in 50mA increments. To determine the correct setting use the charts below. You will need the LED array voltage. Divide the wattage from the battery pack being used by the LED array voltage and chose the next lowest setting below the calculated result. Example: Installation of a 24 volt LED array with 4 Watt AA battery pack: 4W / 24V =.166 Amps or 166mA results in choosing setting 1 for 150mA Setting ma A 600 B 650 C 700 D 700 E 700 F 700 Battery Pack Max Array Wattage W, 9.6V AA900mAH 4W W, 9.6V C2500mAH 12W W, 9.6V D4000mAH 20W Warning: Setting a current that exceeds the Battery Pack maximum Power rating will result in insufficient run time and may damage the emergency driver.
5 LED Operation Single Blink: One of the following conditions can cause the LED to single blink: 1. Test switch pressed before completing one hour charging. 2. Battery voltage less than or equal to 4 volts. 3. Battery voltage less than or equal to 8 volts after charging for 48 hours. 4. Battery not being charged. Double blink: One of the following conditions can cause the LED to double blink: 1. LED array current is too high. 2. LED array current is too low.
This Driver Will Operate Constant Current LED Arrays With a Working Voltage Between 11-56VDC And Not Exceeding 20W.
FHS2-UNV-56S SPECIFICATION SHEET: This Is An Original Product From Fulham Co., Inc Description: Emergency LED Driver For Back-up Lighting. This Driver Will Operate Constant Current LED Arrays With a Working
More informationFHS2-UNV-36L INSTALLATION INSTRUCTIONS
Emergency LED Driver Universal Voltage: 100-277VAC, 50/60Hz Output Wattage: 1.2-20W Output Current: 700mA Max. Output voltage range of 12-55VDC This Driver Will Operate The Following LED Modules: Any LED
More informationWHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:
SURE-LITES Installation Instructions For FBP-1-40X IMPTANT SAFEGUARDS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING: 1. READ AND FOLLOW ALL
More informationFHSCP-UNV-10P-L-SD SPECIFICATIONS
SPECIFICATIONS Emergency LED Driver Universal Voltage: 100-277VAC, 50/60Hz Output Wattage: 1-10W Output Current: 620mA Max. Long Case and Terminal Output voltage range of 16-55VDC This Driver Will Operate
More informationFHS2-UNV-56S SPECIFICATIONS
SPECIFICATIONS MECHANICAL DATA NiCd/LiFePO4 E313578 Emergency LED Driver Universal Voltage: 100-277VAC, 50/60Hz Output Wattage range of 1.2-20W Output Current range of 100mA - 700mA Output voltage range
More informationBAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination
BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination APPLICATION The BAL1400 fluorescent emergency ballast works in conjunction with the AC ballast to convert
More informationUFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS
FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. - To
More informationUFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS
FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. - To
More informationUL AND CODE COMPLIANCE
BAL500 FLUORESCENT EMERGENCY BALLAST 500 Lumens APPLICATION The BAL500 fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures into emergency
More informationBAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination
BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination APPLICATION The BAL3000 fluorescent emergency ballast works in conjunction with an AC
More informationINSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:
IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. CAUTION To prevent electrical
More informationInstallation and Operation Instructions 10/04/13
ELI-S-100 With DIMMING CAPABILITIES Installation and Operation Instructions eli series emergency lighting inverters NRTL/C! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS
More informationFHSCP-UNV-10P-L-SD INSTALLATION INSTRUCTIONS
Emergency LED Universal Voltage: 100-277VAC, 50/60Hz Output Wattage: 1-10W Output Current: 620mA Max. Long Case and Terminal Output voltage range of 16-55VDC This Will Operate The Following LED Modules:
More informationINSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:
INSTRUCTION MANUAL IMPORTANT SAFEGUARDS SERIES D LIGHTING EQUIPMENT When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY
More informationINSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:
INSTRUCTION MANUAL IMPORTANT SAFEGUARDS SERIES D LIGHTING EQUIPMENT When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY
More informationINSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:
SERIES E Emergency Lighting Equipment IMPTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
More informationBAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:
1/19/2012 Fluorescent 1450-3000 Lumens Works in conjunction with an AC ballast to convert new or existing fluorescent fixtures into unobtrusive emergency lighting Maintains illumination of one or two lamps
More information3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.
FLUORESCENT EMERGENCY BALLAST WARNING: When using this lighting device, safety precautions should be followed at all times. CAUTION: Verify that all replacement lamp types marked on the installed luminaire
More informationBALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST
BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST APPLICATION The BALT5-800 low-profile fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures
More informationInstallation Instructions Central Battery Units
Phone: 605.542.4444 concealite.com! Installation Instructions s Please Save These Instructions Important Safeguards Read and Follow All Safety Instructions When using electrical equipment, basic safety
More informationKT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.
FLUORESCENT EMERGENCY BALLAST WARNING: When using this lighting device, safety precautions should be followed at all times. CAUTION: Verify that all repalcment lamp types marked on the installed luminaire
More informationSURE-LITES FBP140XLP Instruction Manual
SURELITES Instruction Manual IMPORTANT SAFEGUARDS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. CAUTION:
More informationSPECIFICATION SHEET : FHS2-UNV-36L
SPECIFICATION SHEET : FHS2-UNV-36L This Is An Original Product From Fulham Co., Inc Description : Emergency LED Driver For Back-up Lighting This driver will operate constant current LED arrays with a working
More informationInstallation Instructions
When using this lighting device the safety precautions should be followed at all times. PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS F YOUR OWN SAFETY 1. This device is designed for indoor use. Do
More informationINSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:
More informationSelf-Testing Industrial Series
Series: AS-I (Maint.-Free) Self-Testing Industrial Series Emergency Lighting Equipment Instructions for INSTALLATION OPERATION SERVICE SPECIFICATIONS 1300650 1300654 1300666 1300754 1300823 1300886 Hubbell
More informationEEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES
INSTALLATION, OPERATION & MAINTENANCE DATA SHEET (EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES) EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES CAUTION:
More informationInstallation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.
Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.7WL, 17WL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety
More informationIMPORTANT SAFEGUARDS
INSTRUCTION MANUAL NON-INTERRUPTIBLE AC INVERTER SYSTEM MODEL EAC FTM 350 FOR EMERGENCY LIGHTING POWER IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed,
More informationSpectron Industrial Series
1300650 1300654 1300666 1300754 1300823 1300886 Table B Constant Value per Voltage System Wire Size (Maximum Voltage Drop 5%) System 6 Volt 12 Volt 24 Volt Wire Size #12 #10 #8 #6 #12 #10 #8 #6 #10 #12
More informationSPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks
Project Type Model # Remarks Description: Firehorse Emergency Ballast for use with or without AC ballast designed to add emergency lighting when main AC power is interrupted for minimum of 90 minutes at
More informationIMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS
THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. IMPORTANT SAFEGUARDS INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL When using
More informationIMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS
THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. IMPORTANT SAFEGUARDS INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL When using
More informationEMIU 720W Mini Inverter
THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using
More informationPrestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS
Prestige Series Edge-Lit LED Sign AC, AC/DC and Self-Powered models Prestige Series Edge-Lit LED Sign WARNING: Risk of Shock. Disconnect Power before Installation. IMPORTANT SAFEGUARDS When using electrical
More informationFLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times
FLUORESCENT 400 Lumens INSTALLATION INSTRUCTIONS When using this lighting device safety precautions should be followed at all times PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY.
More informationMIRRORLITE RECESSED EMERGENCY LIGHTING
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. MIRRORLITE RECESSED EMERGENCY LIGHTING INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should
More informationMorris Products 53 Carey Road, Queensbury, NY 12804
Catalog Number 790 UPC Number 60986790 Description Low Profile Emergency Lighting allast 500 Lumen T5 & T8 Fixtures Features For both normal and emergency Flourescent lighting. In the event of a Power
More informationIMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS!
IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. When using electrical equipment, basic safety precautions should always be followed including the following: DISCONNECT AC POWER SUPPLY BEFORE
More informationB33 INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!
33 INSTAATION INSTRUCTIONS! IMPTANT SAFGUARDS! WHN USING CTRICA QUIPMNT, ASIC SAFT PRCAUTIONS SHOUD AWAS FOOWD, INCUDING TH FOOWING: RAD AND FOOW A SAFT INSTRUCTIONS 1. To prevent high voltage from being
More informationMA-4025 Solar Charger Patent pending
Features Portable Fast-Charge Solar Battery Charger Maximum Power Point Tracking Up to 30% more power No User Input Required Fully Ruggedized Design Over Temperature Protection Wide-Range DC Input Capable
More informationSTOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY
STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY WARNING Risk of fire or electrical shock. LED retrofit installations require knowledge of luminaire electrical systems. If not qualified,
More informationInstallation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Crystal Recessed Edge- lit LED Exit Signs Series CRRBB & CRRAC Battery Backup & AC Models 01.18.06 Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS
More informationSure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards
049-289 Sure-Lites Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. WARNING Risk of Fire/Electric Shock If not qualified, consult an electrician. WARNING Risk
More informationLED Emergency Drivers
LED Emergency Drivers 30 YEARS OF EXCELLENCE Since 1985 Incorporated in the state of California in 1985, McWong International, Inc. has grown to become a strategic supplier of high-quality lighting control
More informationMaxLite LED UTILITY WRAP FIXTURES
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationPRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual
PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com CONTENTS PRM-2 & PRM-3 1. Warranty...3
More informationUsers Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B
Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:
More informationUsers Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B
Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com
More informationGUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT
GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT Service Questions Call: 910-259-1131 IMPORTANT SAFEGUARDS CLASS I DIV 2 HAZARDOUS LOCATION GROUPS A, B, C, AND D ZONE 2 GROUPS IIC, IIB AND IIA CLASS II DIV 2
More informationFixed Head Emergency Lights
EXIT LIGHTING EMERGENCY LIGHTING EMERGENCY LIGHTS Fixed Head Lights Model # Operation Voltage Input Lamp Wattage Battery Voltage Battery Type Damp Location Color JEM-2L-WH 90 Minutes 120V/277V 2x5.4W 6V
More informationInstallation Instruction
T F W 604.549.9379 604.549.9555 fluxwerx.com Installation Instruction DRIVER ENCLOSURE Ceiling Type Version Grid Battery Pack GRID MOUNT INSTALL OPTIONS OPTION 1: Standard Vertical Grid drivers can be
More informationAUTO CHARGE AMPS DELUXE AUTOMATIC BATTERY CHARGER. Section 1: Single Battery Systems
DELUXE AUTOMATIC BATTERY CHARGER Section 1: Single Battery Systems 10 AUTO CHARGE 1000 SINGLE BATTERY SYSTEM AUTOMATIC BATTERY CHARGER & POWER SUPPLY 10 ELEMENT, WATERPROOF BAR GRAPH DISPLAY 18 AMPS TOTAL
More informationPSL600 MVOLT SD INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!
PS600 MVOT SD INSTAATION INSTRUCTIONS! IMPORTANT SAFGUARDS! WHN USING CTRICA QUIPMNT, ASIC SAFT PRCAUTIONS SHOUD AWAS FOOWD, INCUDING TH FOOWING: RAD AND FOOW A SAFT INSTRUCTIONS 1. To prevent high voltage
More informationR. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany
, INC. ECOLUX 6600 Series 6600/5 Explosion Protected Fluorescent Light Fixtures for Hazardous and Corrosive Applications Please read this entire document before beginning any work. 1. Safety Instructions
More informationExit and Emergency Lighting Products PRODUCT CATALOG
Exit and Emergency Lighting Products PRODUCT CATALOG Table of Contents Exit Signs Thermoplastic LED Exit Signs... 4 Thermoplastic Micro LED Exit Signs... 5 Thermoplastic Micro Combo Exit/Emergency Light...
More informationNi - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.
LD7UNVCL Installation Instructions MGNCY LD DIV CLASS 2 OUTPUT WHN USING LCTICAL QUIPMNT, BASIC! IMPOTANT SAFGUADS! SAFTY PCAUTIONS SHOULD ALWAYS B FOLLOWD, INCLUDING TH FOLLOWING: AD AND FOLLOW ALL SAFTY
More information5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810
5 IN 1 JUMP START MODEL NO: JS5IN1 PART NO: 6240005 OPERATION & MAINTENANCE INSTRUCTIONS LS0810 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please
More informationIMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS
LIGHTPATH SERIES LOW LEVEL FULLY RECESSED LED EMERGENCY LIGHT 1. 2. 3. 4. 5. 6. 7. 8. INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always
More informationES750 Battery-powered Cable Cutter
INSTRUCTION MANUAL ES750 Battery-powered Cable Cutter 45380 with 120 V Charger 45381 with 220 V Charger Read and understand all of the instructions and safety information in this manual before operating
More informationSURFACE/CEILING & SUSPENDED MOUNT INSTALLATION
SURFE/CEILING & SUSPENDED MOUNT INSTALLATION E477827 E477827 APPLICATION NL luminaires are designed for use indoors, outdoors, wet locations, areas containing moisture, dirt, corrosion, vibration and rough
More informationInstallation And Operation Instructions
Installation And Operation Instructions For MPS Series Micro-Inverter Power Sytems Lead Calcium Battery Models: MPS-32 and MPS-55 Nickel Cadmium Battery Models: MPS-20 and MPS-35 Surface (-S), Recessed
More informationSAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PSQ500, PS600, PS1400 CAUTION: For safety and proper operation, read and follow instructions carefully before installation. FIELD
More informationConcealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions
Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions Important Safeguards When using electrical equipment, basic safety precautions should always be followed: Read and
More informationInstallation And Operation Instructions
Installation And Operation Instructions For LPS Series Micro Inverter Power Systems Lead Calcium Battery Models: LPS32 and LPS55 Nickel Cadmium Battery Models: LPS20 and LPS35 Surface (-S), Recessed (-R)
More informationInstallation and Operation Instructions SERVICE BY QUALIFIED PERSONNEL ONLY
ELI-S-600 120 Volt ELI SERIES EMERGENCY LIGHTING INVERTERS Installation and Operation Instructions! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,
More informationR. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany
ECOLUX 6608 Series 6608/5 Explosion Protected Fluorescent Emergency Light Fixtures for Hazardous and Corrosive Applications Please read this entire document before beginning any work. 1. Safety Instructions
More informationWhen using electrical equipment, basic safety precautions should always be followed including the following:
INDUSTRIAL INSTALLATION INSTRUCTIONS Illumina BS100LED2FT-PLUS EACH MODEL NUMBER CONSISTS OF THE FOLLOWING: SERIES / LENGTH / OPERATION / LUMENS / COLOUR TEMP. / INPUT SERIES: LENGTH: OPERATION: BS100LED2PLUS
More informationInstallation Instructions and User Manual For. 100 Watt Inverter Power System
Installation Instructions and User Manual For 100 Watt Inverter Power System Installation Instructions and User Manual For LiteGear 100 Watt Inverter Power System Warning: THIS PRODUCT CONTAINS CHEMICALS
More informationPower InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no
WAGAN Corp. Limited Warranty Registration Form All WAGAN Corporation products are warranted to the original purchaser of this product. Warranty Duration: This product is warranted to the original purchaser
More informationLED emergency exit signage from Channel Safety Systems
LED emergency exit signage from Channel Safety Systems CHANNEL SAFETY SYSTEMS t: 0845 884 7000 Petersfield Business Park f: 0845 884 6000 Bedford Road Petersfield Hampshire e: sales@channelsafety.co.uk
More informationHIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS
TM INSTALLATION INSTRUCTIONS IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. Fixtures must be wired in accordance with the National Electrical Code and
More informationDoc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No
The Galileo II range of decorative, wall or ceiling mounted luminaires, are as versatile as they are attractive. The range is available in two body sizes, 350mm and 425mm diameter, and in a variety of
More informationNi - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.
P600STU Installation Instructions UNIVRSA INPUT, SF-ING MRGNC IGHTING QUIPMNT! IMPORTANT SAFGUARDS! WHN USING CTRICA QUIPMNT, ASIC SAFT PRCAUTIONS SHOUD AWAS FOOWD, INCUDING TH FOOWING: RAD AND FOOW A
More informationInformer Compact Series
IMPORTANT SAFETY INSTRUCTIONS Informer Compact Series LINE-INTERACTIVE SINEWAVE UPS Uninterruptible Power System WARNING : (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions.
More informationLumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:
APPLICATIONS LLMPS Series inverter systems are designed to provide sinusoidal AC emergency power to incandescent, flourescent, or LED fixtures of between 20 and 55 watts. Surface, recessed or ceiling T-Grid
More informationSAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Champ Fluorescent Luminaires DMVFB Auxiliary Series - 52, 64, & 84 Watt Installation & Maintenance Information SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IF 1713 IMPORTANT SAFEGUARDS READ AND FOLLOW
More information621 Recessed LED Downlights - 2
621 Recessed Downlights - 2 H Description CO Ceiling Cut-Out Diameter The 621 recessed downlight with Chroma technology provides energy efficient light using a cold remote phosphor module by XICATO. Multiple
More information1995 Honda Accord LX. ANTI-LOCK BRAKE SYSTEM' ' BRAKES Honda - Anti-Lock
TROUBLE SHOOTING ANTI-LOCK (ABS) WARNING LIGHT NOTE: ABS system is okay if ABS warning light goes out after engine is started. Diagnostic Trouble Code (DTC) Recognition 1. ABS control unit recognizes system
More informationEmergency Bypass / Shunt Relays (UL924)
Phone: (800) 888-5538 Fax: (765) 883-7505 www.functionaldevices.com sales@functionaldevices.com Bypass / Shunt Relays (UL924) Features Perfect for all emergency shunt lighting applications Up to 16 Amp
More informationConcealite Life Safety Products Model: F5000 Series. Save These Instructions. Read and Follow All Safety Instructions
1. Do not use outdoors. Concealite Life Safety Products Model: F5000 Series (Standard, SD & RT) Save These Instructions Important Safeguards When using electrical equipment, basic safety precautions should
More informationM T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 040709 2003 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter
More informationM T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n dv/dt Filter Series A 440-600 VAC USER MANUAL PART NO. INSTR - 019 REL. 041119 2004 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation dv/dt Filter is designed
More informationMANUFACTURED IN THE UK
The Trojan range of energy efficient bulkhead fittings are manufactured with a polycarbonate base and diffuser. Together with a poured gasket the Trojan leads vandal-resistant IP65 technology. With a hinged
More informationNova UAC (NV-UAC-M) Modified Sine Wave 650W 800W 1000W
ova UAC (V-UAC-M) Modified Sine Wave 650W 800W 1000W ISTRUCTIOS IMPORTAT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: 1. READ
More information2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years
2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years The Trojan range of energy efficient bulkhead fittings are manufactured with a polycarbonate
More informationOperating instructions 1 4 Mode d emploi 5 8 Instrucciones de uso 9 13 Manual de instruções 15 18
*336376* 336376 SFC 7/18 USA CDN E P Operating instructions 1 4 Mode d emploi 5 8 Instrucciones de uso 9 13 Manual de instruções 15 18 R 1 2 UL Listed to U.S. and Canadian safety standards C US LISTED
More informationThe 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.
1 Elmdene International Ltd Tel: +44 (0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44 (0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk STANDBY 220V AC POWER SYSTEM IDEAL
More informationOPERATION & MAINTENANCE INSTRUCTIONS
AUTOMATIC BATTERY CHARGER / MAINTAINER MODEL NO: CBO9-12 PART NO: 6267025 OPERATION & MAINTENANCE INSTRUCTIONS LS0315 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use
More information12 amp RMS Battery Charger
12 amp RMS Battery Charger 83-5000-12 If faults cannot be remedied, contact the Helpline on 020 8391 6767 helpline@hilka.co.uk Manufactured under license by Hilka Pro Imports GUARANTEE This product is
More informationMANUFACTURED IN THE UK
The Galileo II range of decorative, wall or ceiling mounted luminaires, are as versatile as they are attractive. The range is available in two body sizes, 350mm and 425mm diameter, and in a variety of
More informationProduct Installation Document
Honeywell 12 Clintonville Road Northford, CT 064721610 http://www.honeywellpower.com HP1205UL4, HP1205UL8, HP12010UL8, HP1210UL16 Power Supplies/Distribution Units PN 0618131: A 07/18/13 Product Installation
More informationM T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 060628 2006 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter
More information55185 EMERGENCY PACK FOR LED PANEL TECHNICAL DATA SHEET
FEATURES SPECIFICATIONS Power Consumption 10W Output Voltage 18~59Vdc MAX Input Current 500 ma Emergency Time 90 Minutes Battery Specification 14.4V/2000mAH Dimension (Inches) 12.6 (L) x 1.8 (W) x 1.3
More informationAssembly Instructions Retrofitting
Assembly Instructions Retrofitting These instructions are for replacing existing lighting fixtures or systems with our new, higher efficiency TLS, drivers and controls. www.tls-lumisign.com 514-858-6556
More information1000-Watt Energy Center
1000-Watt Energy Center OPERATING INSTRUCTIONS Patent Pending Sierra Wave 1000-Watt Energy Center #9675 The Sierra Wave 1000-Watt Energy Center is a heavy duty and efficient portable power center offering
More informationAEROBAY INSTALLATION INSTRUCTIONS
AEROBAY INSTALLATION INSTRUCTIONS AEROBAY IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. Fixtures must be wired in accordance with the National Electrical
More informationGeneral Precautions. Personnel Precautions
USER MANUAL General Precautions 1. Before using Inverex, read all instructions and cautionary markings on : (1) Inverex (2) the batteries (3) this manual 2. CAUTION --To reduce risk of injury, charge only
More informationInstallation And Operation Instructions
Installation And Operation Instructions For PS Series Mini-Inverter Power Systems Models: PS-55-LP, PS-110-HP, PS-110-LP, PS-220-HP Surface (-S), Recessed (-R) and Ceiling T-Grid (-T) Mounted Versions
More informationLED Drivers A Practical Understanding for Lighting Applications. Dr. Adan Hernandez, Philips-Advance Al Marble, Philips-Advance
LED Drivers A Practical Understanding for Lighting Applications Dr. Adan Hernandez, Philips-Advance Al Marble, Philips-Advance Outline What is a driver? Design types Constant current vs. constant voltage
More information