Assembly Instructions Retrofitting
|
|
- Alexandrina Grant
- 5 years ago
- Views:
Transcription
1 Assembly Instructions Retrofitting These instructions are for replacing existing lighting fixtures or systems with our new, higher efficiency TLS, drivers and controls
2 Components To calculate the amount of components needed, calculate the square footage of the surface. Approximately 2.5 LED boards/sf and 5 PCB Holders/SF are needed. The number of anchors and tensioners depend on the size and shape of the TLS required. Each full LED board requires 3 watts. To calculate which power supply is needed, use the following formula and associated table. Number of LED boards X 3 Watts = < 85W HLG-100H-24A 86~125.5W HLG-150H-24A 126~204W HLG-240H-24A 205~272W HLH-320H-24A Please contact us for more information at info@tls-led.com to calculate the components for your project.
3 WARNING - Risk of fire or electric shock. TLS Retrofit installation requires knowledge of sign electrical systems If not qualififed, do not attempt installation. Contact a qualified electrician. - Install only in host signs that have been identified in the installation instructions and where the input rating of the retrofit kit does not exceed the input rating of the sign. - Installation of this TLS Retrofit may involve drilling or punching of holes into the structure of the sign. Check for enclosed wiring and components to avoid damage to wiring and electrical parts. - Installer should examine all parts that are not intended to be replaced by the TLS Retrofit for damge and replace any damaged parts prior to installation. - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
4 IMPORTANT - The TLS Retrofit requires an enclosure rated sign face marked where readily visible during servicing with the following: WARNING: This sign is provided with an enclosure rated sign face. Replace only with an enclosure rated sign face. - If the sign face does not have a recognized UL outdoor enclosure rating, please do not attempt installation of the TLS Retrofit and contact your LumiSign representative. -Certified (Listed) signs follow the marking requirements of NEC Section and UL 48. A sign must be marked with the identification of the manufacturer or an identifying trade name or trademark, along with electrical voltage and current ratings. -Signs must also be marked to show any restrictions on where the sign can be properly installed. Indoor only signs are to be marked Dry Locations Only. -Outdoor signs that are evaluated for a damp location are marked Suitable for Damp Locations or, for a wet location, are marked Suitable for Wet Locations. Signs that have a damp or wet location marking are evaluated for compliance with applicable performance testing before they can be marked as suitable for installation in these types of environments. Continue
5 IMPORTANT - continued -All required markings and the UL Certification (Listing) Mark are to be permanently applied and are permitted to be affixed to any exterior surface of the sign, except the sign face, or the interior of the sign where the markings are available for inspection without uninstalling the sign.
6 LED BOARDS Model Number: Located here on the LED Board (On both sides if double-sided)
7 POWER SUPPLY Model Number: HLG-100H-24A HLG-150H-24A HLG-240H-24A HLG-320H-24A - 90~305VAC input, built-in active PFC function - 96% high efficiency - Metal case, IP67/IP65 design for indoor or outdoor installations - Built-in 3 in 1 dimming function (1~10VDC, PWM signal or resistance) for B type PLEASE NOTE: When multiple LED Drivers are required. Installation shall be not less than 1 inch (25.4mm) apart when arranged end-to-end, and not less than 4 inches (102 mm) apart when arranged otherwise.
8 Tensioner LED Board x x x x Positive Cable Terminal (Red) Negative Cable Terminal (Black) Positive Electrical Wire Bridge (Red) Negative Electrical Wire Bridge (Black) Tensioner + Full TLS LED x column(s) Segmented TLS LED x column(s) x Power Supply x Positive Anchor U Channel (Red) x Negative Anchor U Channel Step 1: Component List Remove the parts from the package and place it on a clean surface. Verify the amount of components listed above.
9 Ballast Fluorescent tube C A B REMOVE Step 2 A. TURN OFF ALL POWER TO THE LIGHT BOX (at the breaker or the disconnect switch). Wipe excess dust from inside the light box. B. Remove fluorescent tubes, ballast and ballast secondary wiring, and lampholders. C. Repair and seal any unused openings in the enclosure. Openings greater then 12 mm (.5 in) in diameter require a metal patch secured by screws or rivets and caulked with non-hardening caulking. Smaller openings may be sealed with non-hardening caulking.
10 A B 5/5 4/5 65 mm 3/5 2/5 1/5 C 60 mm Step 3 A. To begin placing the TLS, mark a horizontal line 65mm from the back of the frame. B. Remove one LED board and place it at the base of the frame (where the U Channels will be screwed). Be sure to place the markings as illustrated according to the size of the LED board. C. To measure the distance between the LED columns, use a third board to ensure the last LED of the left column and the first LED of the right column align with the distance of the LEDs of the third LED strip (If needed). Repeat as needed for the top U Channels and for additional columns.
11 A B Step 4 A. Align the set screw of the anchor with the veritcal marking from the LED board. B. Then align the groove that runs horizontally in the U Channel with the horizontal marking. Screw the U channels in place. NOTE: MAKE SURE TO PLACE THE ANCHORS AS POSITIVE, NEGATIVE, POSITIVE, NEGATIVE, ETC.
12 Step 5 Disconnect switch installation: If the circuit is protected upstream by circuit breaker then you would not require a local disconnect. If determined that a disconnect switch is required: - Verify both the disconnect switch is in the OFF/O position. - Mount the disconnect switch to the enclosure. ATTENTION! Ensure that no voltage is present on all power wires per Standards for Electrical Safety Requirements and by your local electrical codes before proceeding. How to wire a disconnect: -The Line side is the cable supplying voltage from your electrical panel. -The Load side is the side that is connected to the power supply. The grounds connect to a lug that is screwed to the disconnect enclosure. If there is not already one pre-installed you will need to install one by screwing it to the enclosure. NOTE: MAKE SURE YOU CHECK THE REGULATIONS IN THE NATIONAL ELECTRICAL CODE AND YOUR LOCAL ELECTRICAL CODES REGARDING THE DEVICE YOU ARE WIRING.
13 V- (BLACK) V+ (RED) A C B + - GRND (GREEN / YELLOW) ACL (BROWN) MEAN WELL ACN (BLUE) Step 6 A. Install the driver (power supply) inside the box. B. Enclose the primary wires (line voltage) inside the box. The proper AC input connections to the driver are marked on the driver. There is a Ground, ACN (Neutral), and ACL (Line). C. DC Driver Output: Connect Red Wire to Red Wire of the TLS positive anchor, and Black Wire to Black Wire of the negative anchor. If the frame is of a conductive material, ensure that there is no continuity between Positive and Negative Anchor. Test voltage on each anchor 24V
14 A B C Step 7 Before starting, make sure to properly place the tensioners to the corresponding colored anchors (Black to black, red to red). Always start from the top. A. To start installing the lighting system, place the tensioners on the anchors. B. Swivel the adjusting nut around the anchor s set screw to connect the systems. Ensure the system is tensioned to its maximum. C. Adjust the nut to lock the tensioner in place.
15 Step 8 Before installing the sign face, verify that the material used is UL certified. ( TURN ON the system at the breaker or disconnect switch.
Installation Guide. WARNINGS Read all instructions and warnings before attempting installation
Installation Guide WARNINGS Read all instructions and warnings before attempting installation ALWAYS MAKE ABSOLUTELY SURE THE POWER IS OFF WHEN PERFORMING THE FIXTURE MODIFICATION. DURING INSTALLATION,
More informationPDX and PX Retrofit Series
UNIQUE LIGHTING SOLUTIONS PDX and PX Retrofit Series PDX1-1-12-XX PX1-1-12-X-X-XX-65 RETROFIT INSTALLATION GUIDE PDX and PX Series Retrofit WARNING -Retrofit installation must only be performed by a licensed
More informationStik Families GENERAL PURPOSE RETROFIT SIGN CONVERSION FOR USE ONLY IN ACCORDANCE WITH KIT INSTRUCTIONS
Stik Families Qwik Stik, Street Stik, Slim Stik, Tap Out Stik Product Retrofit Guide WARNING Installation must only be performed by a licensed electrician. To prevent death, injury or damage to property
More informationInstallation Instructions: HYPERION R-Lite SYSTEM
Installation Instructions: HYPERION R-Lite SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read
More informationwww.greenelectricalsupply.com 1x4 2x2 & 2x4 Read all instructions and warnings before attempting installation. RISK OF FIRE OR ELECTRIC SHOCK. LED RETROFIT INSTALLATION REQUIRES KNOWLEDGE OF LUMINAIRES
More informationStrip Fixture URS Light Bar Retrofit Installation Instructions Revised:
Strip Fixture URS Light Bar Retrofit Installation Instructions Revised: 20180126 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency
More informationUL AND CODE COMPLIANCE
BAL500 FLUORESCENT EMERGENCY BALLAST 500 Lumens APPLICATION The BAL500 fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures into emergency
More informationUniversal Retrofit System Installation Instructions Revised:
Universal Retrofit System Installation Instructions Revised: 20150624 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency to
More informationSTOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY
STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY WARNING Risk of fire or electrical shock. LED retrofit installations require knowledge of luminaire electrical systems. If not qualified,
More informationBAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination
BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination APPLICATION The BAL1400 fluorescent emergency ballast works in conjunction with the AC ballast to convert
More informationULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS
Ultra Performance LED Tube Installation Instructions Page 1 of 7 ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS These instructions do not purport to cover all details or variations in components
More informationInstallation Instructions: Memory-Dimmable SEP T8 Tube Lamps
Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps Installation Notes & Precautions: Memory-Dimmable SEP T8 LED Tube Lamp Read all precautions, warnings, instructions contained in this document.
More informationLED 2/3/4ft T8 Tube 120V
E-T8-1200-YR LED 2/3/4ft T8 Tube 120 Our LED Tubes utilize the latest LED chips as the light source, whilst using the standard T8 end caps, which makes it easy to install and replace traditional fluorescent
More informationLM79 LM80 L70:5+ YEARS
1.30.18 Want to make your shop Highly Efficient, too? Reduce install mistakes and improve efficiency by transforming your shop with our 24volt System. With our 24volt PhxNRG MODULES, our 24volt PhxNRG
More informationInstruction/Installation Manual
Instruction/Installation Manual Retrofit:LED Tube Lamp 4ft. Fluorescent T8/T10 Replacement 1 SECTION 1 - General Information Kit components:1-led Tube, 1-Label and 1-Set of Instructions Models were only
More informationInstallation Instructions: External-Driver SEP T8 LED Tube Lamp
Installation Instructions: External-Driver SEP T8 LED Tube Lamp Installation Notes & Precautions: External-Driver SEP T8 LED Tube Lamp Read all precautions, warnings, instructions contained in this document.
More informationLED Recessed Troffer Retrofit Kit
Model # TRK series LED Recessed Troffer Retrofit Kit Installation Instructions PACKAGE CONTENTS A B E Part Item Name Qty. A Retrofit assembly 1 B Bracket 2 C Sheet metal screw 4 D Wire nuts 5 E Gap channel
More informationTECTONIC LED CORP. ISO
TECTONIC TECTONIC LED CORP. ISO 9001:2000 Products RoHs Compliance Instruction Menu Retrofit:LED Tube Lamps SECTION 1 - General Information Kit components: 1-LED Tube, 1-Label and 1-Set of Instructions
More informationLumination TM LED Luminaire LUR Series
Installation Guide Lumination TM LED Luminaire LUR Series BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT RISK OF FIRE OR ELECTRIC SHOCK Turn power off before inspection,
More informationBAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination
BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination APPLICATION The BAL3000 fluorescent emergency ballast works in conjunction with an AC
More informationProduct Installation Instruction LED Tube Lamp Retrofit Kits
Regular T8 internal driver single end Product Installation Instruction LED Tube Lamp Retrofit Kits 1 General Description LED Tube Light adopts the new type LED as the light source, using the standard T8
More informationInstallation Instructions: ACCENT SYSTEM
Installation Instructions: ACCENT SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read this entire
More informationWHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:
SURE-LITES Installation Instructions For FBP-1-40X IMPTANT SAFEGUARDS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING: 1. READ AND FOLLOW ALL
More informationBAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:
1/19/2012 Fluorescent 1450-3000 Lumens Works in conjunction with an AC ballast to convert new or existing fluorescent fixtures into unobtrusive emergency lighting Maintains illumination of one or two lamps
More informationBALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST
BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST APPLICATION The BALT5-800 low-profile fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures
More informationInstallation Instructions: ACCENT HIGH OUTPUT SYSTEM
Installation Instructions: ACCENT HIGH OUTPUT SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS
More informationInstallation Instructions
When using this lighting device the safety precautions should be followed at all times. PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS F YOUR OWN SAFETY 1. This device is designed for indoor use. Do
More informationLUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps
Gen 1 Installation Guide LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps Type C - External Driver Installation Description The LUNERA T8 LED RETROFIT KITS
More information3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.
FLUORESCENT EMERGENCY BALLAST WARNING: When using this lighting device, safety precautions should be followed at all times. CAUTION: Verify that all replacement lamp types marked on the installed luminaire
More informationAsymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.
support@i2systems.com www.i2systems.com Electrical Specifications PARAMETER Input Power VALUE 8 Watts* / Ft Input Voltage 120-277V AC, 50/60 Hz Max. Fixture Run Length LED Color (CCT) 8 Watts: 120VAC:
More informationWARNING. Tools: 1. Wire Strippers 2. Screw Driver or Rivet Gun 3. Tape Measure 4. Drill. Components: AWG (0.82mm) Wire-UL Approved
Tools: 1. Wire Strippers 2. Screw Driver or Rivet Gun 3. Tape Measure 4. Drill Components: 1. 1 AWG (0.2mm) Wire-UL Approved *Under certain conditions, a heavier gauge wire may be necessary. 2. General
More informationHPNLS-HO. Installation Manual
Installation Manual WARNING: Do not lift fixture by cables. This could result in permanent damage to both the fixture and the cables. Damage resulting from grasping cables and/or putting undue pressure
More informationKT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.
FLUORESCENT EMERGENCY BALLAST WARNING: When using this lighting device, safety precautions should be followed at all times. CAUTION: Verify that all repalcment lamp types marked on the installed luminaire
More informationREAD AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.
Installation Instructions 2RTLEDR/2RTLEDRT Relight Assembly READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION. IMPORTANT SAFETY INSTRUCTIONS WARNING:
More informationLED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage from fire, electric shock, falling
More informationREAD AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION
UR Series LED Upgrade Kit Includes: 24" Linear Option IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL
More informationOPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS
OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS 99-24283-I001 Table of Contents 1. 24V LED Approved Drivers 5 1.1. 24V LED Driver (60-19910-0002).. 5 2. Optimax Radiant 24V LED Lighting. 6 2.1. OP30 6 2.2.
More informationINSTALLATION INSTRUCTIONS
LED LIGHT ENGINE APPLICATION PROGRAM INSTALLATION INSTRUCTIONS LED Light Engine Kit Model: 9 Round Engine 120V: TRIAC DIMMING TKT120025RDxx-01 TKT120025RDxx-11 TKT120021RDxx-01 TKT120021RDxx-11 TKT120025RDxx-02
More information1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".
SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,
More informationINSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02
INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02 Important safety information - read all instructions before installation. WARNING Risk of fire or electric shock. Luminaire wiring and
More informationINSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:
More informationSynergEX Panelboards for Hazardous Locations
SynergEX Panelboards for Hazardous Locations Installation & Maintenance Information 1. APPLICATION SynergEX panelboards provide short circuit protection for feeder or branch circuits to control lighting,
More informationWARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.
Tetra Contour LS LED Lighting System GEXNLBL-1, GEXNLGL-1, GEXNLRD-1, GEXNL65-1, GEXNL32-1 Installation Guide 24 Volt BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT
More informationSURE-LITES FBP140XLP Instruction Manual
SURELITES Instruction Manual IMPORTANT SAFEGUARDS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. CAUTION:
More informationMAXLITE RKT LED Retrofit Kit
MAXLITE RKT LED Retrofit Kit Description and Intended Use The RKT LED Retrofit Kit is a high performance LED Fixture upgrade kit designed to replace the original components inside 2 x2 and 2 x4 fluorescent
More informationHPFB. Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES.
Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES. This could result in permanent damage to both the fixture and the cables. Damage resulting from grasping cables and/ or putting undue pressure
More informationLED. High-performance streetlight. -afortable and reliable
LED High-performance streetlight -afortable and reliable DESIGNED FOR FUNCTIONAL LIGHTING OF OUTDOOR ROADS WHERE ENERGY SAVING, LOW MAINTENANCE AND PRECISE LIGHT CONTROL CONSIDERATIONS ARE IMPORTANT FACTORS.
More informationTetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide
Installation Guide Volt Tetra minimax LED Lighting System GEMMRD-W, GEMMGL-W, GEMMBL-W BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSMENT RISK OF ELECTRIC SHOCK Turn
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More informationQuick Installation Guide. Affinium LED Modules LFM300 for Refrigerated Display Cases
Quick Installation Guide Affinium LED Modules LFM300 for Refrigerated Display Cases Important Please take the time to read this installation guide before you install the Affinium LED modules and LED power
More informationREAD AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.
Installation Instructions RT8RT/RT5RT Relight Assembly READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION. IMPORTANT SAFETY INSTRUCTIONS WARNING: FAILURE
More informationSky FactoryTM. Classic w/ EcoSlim Electrical Instructions (HLG) Installation Instruction includes:
Sky FactoryTM www.skyfactory.com toll free 1.866.759.3228 Classic w/ EcoSlim Electrical Instructions (HLG) Junction Box Black wire is negative Red wire is positive 24 volt DC Power Supply Installation
More information1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.
More informationNICHE-HV. Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES.
Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES. This could result in permanent damage to both the fixture and the cables. Damage resulting from grasping cables and/ or putting undue pressure
More informationLED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:
LED Area Light This is the fixture of choice for all of our dealerships. Contact Us: 7057 Marcelle St, Paramount, CA 90723 800-640-0386 www.altechefficiency.com sales@altechefficiency.com Specifications
More informationUFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS
FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. - To
More informationINSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:
INSTRUCTION MANUAL IMPORTANT SAFEGUARDS SERIES D LIGHTING EQUIPMENT When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY
More informationSloanLED THINLED. Constant Current. Installation Guide
SloanLED THINLED Constant Current Installation Guide Product covered in this guide: ThinLED CC: Part Number Description 701228-18-A Amber ThinLED Constant Current 701228-18-B Blue ThinLED Constant Current
More informationINSTALLATION GUIDE AND USER MANUAL
Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: 30A EVoCharge EVSE Model Number: EV072-300-001A Product Safety Certification: UL and cul Listed Description: SAE J1772 AC Level
More informationNANO MIX. Installation Manual
Installation Manual WARNING: DO NOT ATTEMPT TO INSTALL OR USE THE NANOLUME FIXTURE WITHOUT READING THE INSTALLATION INSTRUCTIONS AND SAFETY LABELS COMPLETELY. Failure to adhere to these instructions could
More informationUFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS
FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. - To
More informationOptimax Pro Retrofit Instructions
Copyright 2011 by ALL rights reserved. Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless otherwise noted. No part
More informationSolid State T8 tube is the smart alternative to a
Solid State T8 tube Ideal for decorative and ambient lighting in retail outlets, hotels, restaurants, government buildings, and multi-unit residences L Prize Winner Solid State T8 tube Direct Replacement
More informationLED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:
LED Area Light scratch that. This is the fixture of choice for all of our dealerships. Contact Us: 7057 Marcelle St, Paramount, CA 90723 800-640-0386 www.altechelectronics.com sales@altechelectronics.com
More informationINSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032
INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032 Page 1 Thank you for purchasing this Langport Lighting outdoor wall lantern. This product has been manufactured with the highest standards of safety
More informationConcealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions
Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions Important Safeguards When using electrical equipment, basic safety precautions should always be followed: Read and
More informationElectric Vehicle Charging Station
EVoReel Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: Dual Output Pedestal Mount 30A EVoReel EVSE Model Numbers: With Basic EVSE: EV072-400-002A; With Intelligent ievse: EV072-410-002A;
More informationINSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:
SERIES E Emergency Lighting Equipment IMPTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
More informationOwner's/Installation Manual
Owner's/Installation Manual Power Management Module (PMM) and Starter Kit NOTE: The starter kit must be purchased and installed prior to individual PMM usage. Model Numbers: 00686-0 PMM 00699-0 PMM WITH
More informationCFP-LED Contractor Select Flat Panel. Installation Instructions
IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions
More informationLED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)
LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series) PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION SAFETY
More informationNANOTUNE. Installation Manual
Installation Manual WARNING: DO NOT ATTEMPT TO INSTALL OR USE THE NANOLUME FIXTURE WITHOUT READING THE INSTALLATION INSTRUCTIONS AND SAFETY LABELS COMPLETELY. Failure to adhere to these instructions could
More informationINSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R
INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R THE RELIANCE Fast/Tran IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by a qualified electrician thoroughly familiar with all
More informationINSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:
INSTRUCTION MANUAL IMPORTANT SAFEGUARDS SERIES D LIGHTING EQUIPMENT When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY
More informationInstallation Instructions for SINGLE COLOR 24V LINEAR LED NEON
Installation Instructions for SINGLE COLOR 24V LINEAR LED NEON LLI-N2.9W Prior to installation, please confirm that you have the required system components listed below. LED Neon Flow Extrusions/Lens (Optional)
More informationSURFACE/CEILING & SUSPENDED MOUNT INSTALLATION
SURFE/CEILING & SUSPENDED MOUNT INSTALLATION E477827 E477827 APPLICATION NL luminaires are designed for use indoors, outdoors, wet locations, areas containing moisture, dirt, corrosion, vibration and rough
More informationINSTALLATION GUIDE AND USER MANUAL
Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL SAE J1772 AC Level 2 EVSE Model: 30A EVoCharge EVSE Wall Mount P/N: EV072-300-001A Version 2.0 IMPORTANT Read this manual thoroughly
More informationchannel damage the internal components and the weight may break the internal wiring or flexible strip.
YOU MAY NEED End cap Power adaptor Connector pin Splicing pin Connector Silicone glue Pliers Power converter Converter + surge protector Heat shrink Aluminium channel Heat gun NT cutter IMPORTANT NOTES
More informationINSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F
SAFETY S IMPORTANT SAFETY INFORMATION SUITABLE FOR DRY OR DAMP LOCATIONS. NOT FOR USE WITH PHASE CUT DIMMERS. Risk of shock. Disconnect power before installation. DANGER CONVIENT AUX EMPLACEMENTS HUMIDES.
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be
More informationOutdoor Installation Using an Electronic LED Power Supply (TE-60L-12)
0 Edge Lighting. All Rights Reserved. 78 W. Fullerton Ave Chicago, IL 606 Tel: 77-770-9 Fax: 77-9-6 www.edgelighting.com info@edgelighting.com Installation Instructions for Port Round & Square LED PORT-RD-ST-SA
More informationNOTE: The orientation of the mounting brackets are critical. (See Figure 4)
Page 1 of 5 11.25.13 Lamping Specifications 10138 I-wall 2 120v, One, F14WT5/Mini Bi-Pin 277v, One, F14WT5/Mini Bi-Pin 10139 I-wall 3 120v, One, F21WT5/Mini Bi-Pin, 277v, One, F21WT5/Mini Bi-Pin 10140
More informationINSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit
10W DirectAC Engine TJT120010ACxyyB 15W DirectAC Engine TJT120015ACxyyB INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit TJT120010ACxyyB TJT120015ACxyyB TJT120023ACxyyB TJT120010ASxyyC TJT120010ACxyyC
More informationInstallation Instructions for Sun 3 RGB LED. Section One: Install the Constant Current DMX Driver
Intelligent LED Driver/Controller Output 060VDC, 00050mA, 00W SELV equivalent : 90% typ. in in out out in in out out Group Group Group LEDcode Group Group Group LEDcode 06 Edge Lighting. All Rights Reserved.
More informationFLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times
FLUORESCENT 400 Lumens INSTALLATION INSTRUCTIONS When using this lighting device safety precautions should be followed at all times PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY.
More informationINSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems
INSTALLATION GUIDE For Carrier/Bryant Residential Power Systems For 100 Amp Automatic Transfer Switch/Load Center Model: KGATX0116100 16 circuit installed with 16kW generators. This Automatic Transfer
More informationNew dimming drivers are compatible with most wall dimmers for % light control. For non-dimming
CONSTANT VOLTAGE POWER SUPPLIES CONSTANT VOLTAGE New dimming drivers are compatible with most wall dimmers for 10-100% light control. For non-dimming applications or for use with AL-PWM-6A, use LED-DR
More informationTechnical Manual. DLM Module. This manual should remain with the unit.
Technical Manual DLM Module This manual should remain with the unit. Safety Rules SAVE THESE INSTRUCTIONS! Read the following information carefully before attempting to install, operate or service this
More informationLED Drivers A Practical Understanding for Lighting Applications. Dr. Adan Hernandez, Philips-Advance Al Marble, Philips-Advance
LED Drivers A Practical Understanding for Lighting Applications Dr. Adan Hernandez, Philips-Advance Al Marble, Philips-Advance Outline What is a driver? Design types Constant current vs. constant voltage
More informationE E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.
5 YEAR WARRANTY 5 YEAR WARRANTY COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS E354088 LISTED AC E354088 58VDC E354088 E354088 5 5 YEAR WARRANTY 5 YEAR WARRANTY E354088 Caution: Observe precautions for
More informationA. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:
SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification
More informationFPU SYSTEMS OPERATION MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH Modular Workshop Container (MWC) BOH FPU Field Pack-up Units CHAPTER 5
FPU SYSTEMS OPERATION MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH Modular Workshop Container (MWC) BOH FPU Field Pack-up Units CHAPTER 5 UNIT MAINTENANCE INSTRUCTIONS 06 BOH Environmental LLC
More informationInstalling Power Components
This chapter provides instructions on how to install and reinstall power components in the Cisco NCS 4016 chassis. It also covers connecting and disconnecting power and powering on the chassis. The Cisco
More informationRapidLED NanoCube 24 Aurora Array Retrofit
1 RapidLED NanoCube 24 Aurora Array Retrofit Contents Overview... 1 Hood Preparation... 2 Hood Power Wiring Preparation... 3 Fan and AC Adapter Wiring... 5 Heatsink Installation... 10 Aurora LED Array
More informationIncentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * )
Incentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * ) Energy Trust offers cash incentives to help you implement approved energy efficient lighting measures. If
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be
More informationCustomer service: or Upper mounting ring. Canopy
Components included: Upper mounting ring Canopy Fixture base Fluorescent - 2 x 42 W 4-pin compact fluorescent lamps required (not included). Lutron recommends GE, Sylvania, or Philips lamps that are certified
More informationG2.1 RETROFIT LED LIGHTING
INSTALLATION INSTRUCTIONS FOR CHEVRON CANOPY: G2.1 RETROFIT LED LIGHTING Please review site plans before proceeding. Contact LSI Graphic Solutions Plus Customer Service at 1-(800) 678-2001 for installation
More informationIMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:
ZR-RK Series LED Retrofit Troffer Kit Includes: ZR22RK and ZR24RK Standard and Emergency Luminaires IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed
More informationdiode led 24VDC MAGNETIC DIMMABLE DRIVER SPECIFICATION SHEET 24VDC OVERVIEW FEATURES
diode led a division of elemental LED 24VDC MAGNETIC DIMMABLE DRIVER 24VDC WET LOCATION DIMMABLE SPECIFICATION SHEET OVERVIEW 24VDC Magnetic Dimmable Drivers are perfect for supplying low voltage power
More information