2 DESIGNER SUPPLEMENTAL INSTRUCTIONS DSI NO. MCA-DSI-0018 DATE: 09/15/2016 PROJECT NAME: NOAB Project # Louis Armstrong New Orleans International Airport North Terminal Development Program Phase 1 Note: if the following information is deemed to have an impact on GMP Price or time, submit a proposal for Owner approval before proceeding with this DSI. If approved by Owner, the resulting contract change will be incorporated in the next formal Change Order. Revised drawing UP P 6001, issued in response to RFI Cost impact: Potential cost increase. Attachments: Partial sheets: Reissued full sheets: UP P 6001 By: Brian Miller

3 R E Q U E S T F O R I N T E R P R E T A T I O N From: Dean Schuerman To: Cedric Johnson CC: Daniel Taylor, David Daileda, Jason Levy, David Zelig, Sara Delahoussaye, Raymond Symanski. Greg DeCoursey, Carlos Giron, Brian Miller, Chad Blanchard RFI From Cedric Johnson To Dean Schuerman CC Cinda Denoux, Daniel Taylor, Jason Levy, Raymond Symanski, Scott Rydin, Cedric Johnson, Cindy Shields, David Daileda, Kiet Vo, Sara Delahoussaye Project North Terminal Project - NOLA (MSY) Construction Subject 5_UP P 6001_CUP_Diesel Fuel-Oil System Subject: 5_UP P 6001_CUP_Diesel Fuel-Oil System Date Required: Cost Impact: Potentially Cost Amount: Question: Mechanical is being asked to provide the diesel fuel-oil supply and return pumps as specified in electrical Para; F.3 & F.4., and while procurement and selection of the pumps, arose concerns by the fuel-oil pump manufacturers with the long suction line that we now have due to the CUP being relocated. To mitigate this concern, the fuel pump manufacturer recommends the following changes to the fuel-oil piping to be incorporated to drawing UP P 6001: Suggestion: Answer: 1. Instead of drawing from the top of the tank, the fuel supply line should come from the side of the tank near the bottom, drawing from the balance line between the two tanks (tank #2 by owner). The tank will sit on pedestals that should be about 3ft tall, and the saddle is 6" tall. If drawn from the tank near the bottom, we should be able to run the pipe over the containment wall or offset slightly up and over. 2. Uncertainty if a mechanical anti-siphon valve will work, it may require installation of a solenoid operated valve that is normally closed and would open if any of the pumps came on. This would require a control panel in the CUP which receives input from each pump and a signal wire from the CUP to the valve at the tank. It would require signal wires running from the CUP to the fuel tanks. 3. NFPA requires that the bottom 5% of the fuel in the fuel tank be unusable. That would require the nozzle for supplying the line to be 1 - from the bottom of the tank. 4. These are subtle changes, and we do not believe any of these changes would affect the SFM review. Would it be acceptable to proceed with these recommendations in order for us to begin procurement and selection of these fuel-oil pumps? If so, we ask a DSI to be issued to reflect the recommendations since it may affect other scopes of work. NOTE: An RFI response cannot change the requirements of the Contract Documents. Response By: Greg DeCoursey Date: 09/16/2016 CCAT Response: It is acceptable to proceed with contractor s recommendations Refer to MCA DSI 0018 Cost Impact: none Pursuant to paragraph of the General Conditions of the Contract, the Engineer of Record provides the following response to the referenced RFI. This RFI response does not constitute a Construction Change Directive, and does not authorize changes in project scope, contract price or time. Refer also to Article 7 of the General Conditions and for AIP work to Article of the FAA General Provisions. RFI s are to be returned for reconsideration if there is a cost or schedule impact.

4

5 A. GENERAL NOTES THE GENERAL PROVISIONS OF THE CONTRACT APPLY TO THE WORK SPECIFIED IN THESE NOTES. PROVIDE ALL NEW MATERIALS, LABOR, TOOLS, EQUIPMENT, TRANSPORTATION, INCIDENTALS, AND SERVICES NECESSARY FOR THE COMPLETE INSTALLATION ON EVERY RESPECT AND THE SATISFACTORY OPERATION OF ALL SYSTEMS AS SPECIFIED BELOW OR AS SHOWN ON DRAWINGS. NORTH TERMINAL LOUIS ARMSTRONG NEW ORLEANS INTERNATIONAL AIRPORT DIKED AREA WITH 60,000 GALLON CONTAINMENT VOLUME AND 1 FREEBOARD. REFERENCE UP S 1113 & UP A 5002 FOR DETAILS CONTAINMENT SIZING AND ASSUMPTIONS 42'X70' INSIDE-TO-INSIDE OF DIKE WALLS, DIKE WALL HEIGHT: 3'10 - CONTRACTOR TO PROVIDE FINAL SIZING FOR CONTAINMENT AREA BASED ON ACTUAL TANKS PURCHASED AND INSTALLED. ASSUMPTIONS: CONTAINMENT FOR (1) TANK RUPTURE TANKS: 14'DIA X 63' LONG; ~60,000 GALLONS TANK PEDESTALS: 14'L X 18 W X 2'6 T; 2 EACH TANK TANK SADDLES: 6 BOTTOM OF SADDLE TO BOTTOM OF TANK 12 FREEBOARD 3% ALLOWANCE FOR PIPING AND MISC. ITEMS OVERFILL/LOW LEVEL ALARM MONITORING PANEL (SEE NOTE E) WEATHERPROOF JUNCTION BOX TO MONITOR PANEL NORMAL TANK VENT EMERGENCY VENT MECH. TANK LEVEL GUAGE MORRISON BRO. MODEL NO#818 OR APPROVED EQUAL MANWAY PANEL B NOTE: EACH FUEL SUPPLY MUST SEND A SIGNAL TO PANEL A WHEN RUNNING. DSI-0018 PANEL A WILL SEND A SIGNAL TO PANEL B IF ANY COMES ON. PANEL B WILL THEN CAUSE THE ELECTRICALLY POWERED SOLENOID OPERATED TO OPEN. FAILS CLOSED WHEN NOT OPERATING. B. C. D. E. F. G. H. I. J. K. L. M. ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE SECTIONS OF LOCAL, MUNICIPAL, PARISH, STATE, FEDERAL, INDUSTRY AND UTILITY COMPANIES RULES, REGULATIONS, CODES, ORDINANCES, AND STANDARDS INCLUDING NFPA 30 AND NFPA 110. MAIN FUEL TANK SHALL BE CYLINDRICAL SINGLE WALL STEEL, 60,000 GALLON CAPACITY, ABOVE GROUND TANK FOR DIESEL FUEL; UL142 LISTED. PROVIDE ANTI-SIPHON PRIMARY AND EMERGENCY VENTS, IN ACCORDANCE WITH NFPA. ALL PIPING CONNECTIONS TO TANK SHALL BE MADE ABOVE THE NORMAL MAXIMUM LIQUID LEVEL. PROVIDE MECHANICAL OVERFILL PREVENTION FOR MAIN FUEL TANK, SINGLE ACTION SHUT-OFF TO AUTOMATICALLY STOP DELIVERY OF LIQUID WHEN LEVEL IN TANK REACHES 95 PERCENT OF CAPACITY, OPW 61S OR APPROVED EQUAL. PROVIDE ABOVE GROUND TANK DIGITAL MONITORING SYSTEM TO MONITOR TANK LEVELS. TANK MONITORING SYSTEM SHALL BE VEEDER-ROOT MODEL TLS-300 TANK LEVEL MONITOR WITH ONE (1) VEEDER-ROOT #8473 MAG 1 TANK PROBE AND INSTALLATION. SEE DRAWING UP M 1111 FOR LOCATION. PROVIDE ALL RELAYS AND ENCLOSURES REQUIRED. LOW VOLTAGE WIRING TO SENSORS AND PROBES SHALL BE PROVIDED UNDER THIS DIVISION. CONDUIT FOR CONTROL WIRING SHALL BE PROVIDED UNDER DIVISION 16. PANEL SHALL PROVIDE CONTINUOUS LED READOUT OF LIQUID LEVEL IN MAIN TANK GIVEN IN GALLONS. PANELS SHALL ALSO PROVIDE DISTINCT ALARM SIGNALS AS FOLLOWS: HIGH LEVEL ALARM AT 90 PERCENT OR GREATER LEVEL OF MAIN TANK NOMINAL TANK CAPACITY. LOW LEVEL ALARM AT MIN 20 PERCENT OF MAIN TANK NOMINAL CAPACITY, ADJUSTABLE BY THE OWNER. FURNISH AND INSTALL AN AUDIO/VISUAL ALARM WITH ACKNOWLEDGMENT SWITCH, VEEDER-ROOT SERIES 8485 OR APPROVED EQUAL, WITH ADJUSTABLE PEAK DBA, AT 10 FEET, MINIMUM HORN, AND LIGHT, 120 VAC. LOCATION ALARM DIRECTLY ABOVE TANK FILLING SYSTEM. PROVIDE LAMINATED SIGN BELOW ALARM READING "FILL LEVEL ALARM". CONDUIT AND WIRING INSTALLATION UNDER DIVISION 16. REMOTE TANK FILLING SYSTEM SHALL BE SIMPLEX MANUAL "FUEL PORT" FFP3 OR APPROVED EQUAL WITH FILL FITTING, & POST ASSEMBLY. I LOCKABLE, WEATHERPROOF BOX, PAINTED WHITE, WITH GROUNDING PROVISION. MOUNT ON THE CONCRETE PAD. DIESEL FUEL LINE INSTALLATIONS - THE CONTRACTOR MUST INSTALL ALL NEW FUEL LINES. THE NEW FUEL LINES SHALL BE AS INDICATED IN SPECIFICATIONS. CONTRACTOR MUST INSTALL ALL NECESSARY SUPPORTS FOR NEW FUEL LINES. WEATHER PROOF AND CORROSION PROOF FLEXIBLE FITTING SHALL BE INSTALLED AT POINT OF ENTRY OF GENERATOR HOUSING. ALL FUEL LINES SHALL BE FLUSHED AND CLEANED PRIOR TO FILLING TANK AND FUEL LINES. FUEL LINES SHALL BE BLACK IRON PIPE. FURNISH AND INSTALL MECH. TANK LEVEL GAUGE, MORRISON BROS. MODEL NO. 818 OR APPROVED EQUAL. TEST FUEL OIL PIPING ACCORDING TO NFPA 30. TEST AND ADJUST CONTROLS AND SAFETIES. REPLACE DAMAGED OR MALFUNCTIONING CONTROLS AND EQUIPMENT. REMAKE JOINTS AND CONNECTIONS USING NEW MATERIALS. BEFORE ACTIVATING SYSTEM PERFORM THESE STEPS: PROJECT ADDRESS KENNER, LOUSIANA ZIP Owner KEY PLAN THE NEW ORLEANS AVIATION BOARD THE NEW ORLEANS AVIATION BOARD, 900 EAST AIRLINE DRIVE, KENNER, LA CRESCENT CITY AVIATION TEAM A JOINT VENTURE 1 GALLERIA BOULEVARD #1516 METAIRIE, LA T (504) / F (504) OPEN S TO FULL OPEN POSITION AND CLOSE BYPASS S. 1 UNION REMOTE FILL ABOVE GRADE (SEE NOTE I) 6" DROP TUBE (AUTOMATIC TANK GAUGING) MAGNETOSTRICTIVE PROBE OVER FILL PREVENTION 60,000 GALLON TANK TANK SUPPORT 1'- PIPE THRU CONCRETE WALL WITH PIPE SLEEVE AND CHEMICAL RESISTANT NON-SHRINK GROUT BALL WITH LOCKABLE HANDLE EQUAL TO FLOW-TEK F15-2-R-10-3-J-R-L EMERGENCY VENT THROUGH WALL WITH BUG SCREEN NORMAL VENT THROUGH WALL WITH BUG SCREEN PANEL A FROM FIRE SUPPLY N. O. P. Q FILL OIL STORAGE TANK WITH PROPER FUEL TYPE. OPERATING CONTROL OF GENERATOR UNITS. OPERATION AT AUTOMATIC S AND LEVEL ALARMS. ALL S SHALL HAVE PROVISIONS FOR AND BE LOCKABLE. COORDINATE WITH AIRPORT PERSONNEL. TO HAVE TWO (2) SUPPLY S AND ONE (1) REVERSE. PROVIDE ALL NECESSARY S, STRAINERS, AND OTHER ACCESSORIES. SEE ENGINE GENERATOR SPECIFICATION AND DIESEL-DRIVE CENTRIFUGAL SPECIFICATION CONTRACTOR HAS THE OPTION TO PROVIDE AN ALTERNATE, COST NEUTRAL, DESIGN FOR THE FUEL OIL PIPING AND S SYSTEM TO BE REVIEWED BY THE ENGINEER OF RECORD. REVISIONS NO. DESCRIPTION DATE L.3 Addendum L.13 Addendum M.1 Addendum CONFORMED SET DSI MCA-DSI OVERFILL/LOW LEVEL ALARM MONITORING PANEL (SEE NOTE E) CONCRETE PAD AND PILING (SEE CIVIL/STRUCTURAL DRAWING) NORMAL TANK VENT LOCATE VENT 12' ABOVE GRADE EMERGENCY VENT TO FIRE FILE LOG ACTIVITY BY Manager LINE TO EQUALIZE LEVELS IN TANKS Design Draw JLC JLC WEATHERPROOF JUNCTION BOX TO MONITOR PANEL MECH. TANK LEVEL GUAGE MORRISON BRO. MODEL NO#818 OR APPROVED EQUAL MANWAY TO FIRE Check STAMP GRC UNION REMOTE FILL ABOVE GRADE (SEE NOTE I) DROP TUBE (AUTOMATIC TANK GAUGING) MAGNETOSTRICTIVE PROBE OVER FILL PREVENTION 60,000 GALLON TANK TANK SUPPORT 1'- S BLOCK SUPPLY SUPPLY SUPPLY Signature: Date: ISSUED FOR CONSTRUCTION PROJECT NO PLUMBING SCHEMATICS 9/15/2016 3:25:07 PM CONCRETE PAD AND PILING (SEE CIVIL/STRUCTURAL DRAWING) 1 FUEL STORAGE SCHEMATIC FLOW DIAGRAM UP P 6001 SCALE: N.T.S. VOLUME 5 UP P 6001 LEO A DALY Company 2015

Winning Bid US Petroleum Equipment Walts Petroleum Northwest Petroleum Petro-Chemical Systems Kimberly Green Bay Wausau Fond Du Lac

Winning Bid US Petroleum Equipment Walts Petroleum Northwest Petroleum Petro-Chemical Systems Kimberly Green Bay Wausau Fond Du Lac Minimum Specifications/Questionnaire Bid Results for One (1) New Fuel Dispensing System-Larrabee Shop Winning Bid PERMIT FEES, FORMS, PLANS and NOTIFICATIONS Secure all necessary state and local permits

More information

ADDENDUM #1. A. Alternate Bid Item #3A - The procurement and installation of a new 12,000 gallon UL 2085 rated AGT tank for

ADDENDUM #1. A. Alternate Bid Item #3A - The procurement and installation of a new 12,000 gallon UL 2085 rated AGT tank for ADDENDUM #1 The Plymouth Airport Commission is committed to fulfilling the New Fuel Farm Facility project within the scope of the permit, not exceeding our funding and to satisfy the time constraint associated

More information

SECTION VEHICLE FUEL DISPENSING EQUIPMENT

SECTION VEHICLE FUEL DISPENSING EQUIPMENT SECTION 23 10 13 PART 1 GENERAL 1.01 SUMMARY A. Provide vehicle fuel storage and dispensing equipment, including but not necessarily limited to: 1. Two compartment above ground gasoline and diesel tank.

More information

FLORIDA DEPARTMENT OF TRANSPORTATION

FLORIDA DEPARTMENT OF TRANSPORTATION FLORIDA DEPARTMENT OF TRANSPORTATION ADDENDUM NO. 1 DATE: 3/8/2011 RE: BID/RFP #: RFP-DOT-10/11-9031-LG BID/RFP TITLE: FURNISH AND INSTALL EMERGENCY GENERATOR POWER SYSTEM AT CARYVILLE OPENING DATE: March

More information

Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD

Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD Part: VST ECS-CS3-310 Three Phase VST-ECS-CS3-110 Single Phase Executive Orders: VR-203 VR-204 Version: 1.1 NOTE:

More information

ADDENDUM NO. THREE (3) INSTALL BACKUP GENERATOR TERMINAL BUILDING SALISBURY-OCEAN CITY: WICOMICO REGIONAL AIRPORT SALISBURY, MARYLAND

ADDENDUM NO. THREE (3) INSTALL BACKUP GENERATOR TERMINAL BUILDING SALISBURY-OCEAN CITY: WICOMICO REGIONAL AIRPORT SALISBURY, MARYLAND ADDENDUM NO. THREE (3) INSTALL BACKUP GENERATOR TERMINAL BUILDING SALISBURY, MARYLAND Delta Project No. 15065 MARCH 15, 2017 From: To: Delta Airport Consultants, Inc. 9711 Farrar Court, Suite 100 Richmond,

More information

Reliant Series Systems Fuel Tanks DAY TANKS FILTRATION TANKS SPECIALTY TANKS

Reliant Series Systems Fuel Tanks DAY TANKS FILTRATION TANKS SPECIALTY TANKS Reliant Series Systems Fuel Tanks DAY TANKS FILTRATION TANKS SPECIALTY TANKS The Simplex Reliant Series is the latest design expression of a seventyyear history of innovation and reliability from the originator

More information

INSTRUCTION MANUAL L WIND CONE

INSTRUCTION MANUAL L WIND CONE Cooper Industries DOCUMENT September 29, 2009 Revision B Crouse-Hinds Division Crouse-Hinds Airport Lighting Products 1200 Kennedy Road Windsor, CT 06095 860 683-4300 Fax 860 683-4354 Title: INSTRUCTION

More information

Aboveground Tank Equipment. Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co.

Aboveground Tank Equipment. Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co. Aboveground Tank Equipment Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co. HISTORY Morrison Bros. Co. Then Founded in 1855 Located in Dubuque, Iowa Originally a boiler manufacturer

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 23 2123 - PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS SECTION 221123.13 - DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS SECTION 22 1123.13 DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

PROJ. NO SECTION HYDRONIC PUMPS

PROJ. NO SECTION HYDRONIC PUMPS SECTION 23 21 23 HYDRONIC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Multi-Institutional Academic Health Science & Research Center Evansville, IN SECTION 263213 - ENGINE GENERATORS PART 1 - GENERAL 1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Earthsafe Systems, Inc. Emergency Power Fuel Systems Recommended System Standard

Earthsafe Systems, Inc. Emergency Power Fuel Systems Recommended System Standard Copyright 2008 Earthsafe Systems, Inc. This information is provided to consulting engineers and prospective customers for the purpose of specifying Earthsafe Emergency Power Fuel Systems. Reproduction

More information

A. The latest published edition of a reference shall be applicable to this Project unless identified by a specific edition date.

A. The latest published edition of a reference shall be applicable to this Project unless identified by a specific edition date. SECTION 22 50 00 FUEL OIL PIPING SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01 00,

More information

Tank Filling Systems. for Petroleum Products

Tank Filling Systems. for Petroleum Products Tank Filling Systems for Petroleum Products Tank Filling Systems for Petroleum Products page 2 What Is It Used For? Generally used with aboveground storage tanks, although some underground uses as well.

More information

Utility Distribution Systems Installation, Operation, and Maintenance Manual

Utility Distribution Systems Installation, Operation, and Maintenance Manual Utility Distribution Systems Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately

More information

INVITATION TO BID. January 10, 2018

INVITATION TO BID. January 10, 2018 INVITATION TO BID January 10, 2018 The City of Bainbridge will receive sealed bids for ONE NEW PORTABLE TANDEM STATIC ROLLER to be LEASED FOR PURCHASE, as described in the attached specifications until

More information

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Multi-Institutional Academic Health Science & Research Center Evansville, IN SECTION 221123.13 - DOMESTIC-WATER PACKAGED BOOSTER PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Related Sections: 1. Section 15050 - Basic Mechanical Requirements. 2. Section 15051 - Motors. 3. Section 15185 - Hydronic Pumps. 4. Section 15625 - Centrifugal

More information

Code Requirements on Aboveground Storage Tanks Dispensing Fuels At Motor Vehicle Fuel-Dispensing Stations

Code Requirements on Aboveground Storage Tanks Dispensing Fuels At Motor Vehicle Fuel-Dispensing Stations Code Requirements What follows is a detailed chart developed by Steel Tank Institute s executive vice president, Wayne Geyer, P.E. Fire codes play a prominent role in tank purchase decisions. As such,

More information

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS SECTION 15160 - PUMPS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL

More information

SECTION VIII. (Sub-section 430) Wastewater Valves and Appurtenances. 1. General thru Gate Valves thru 430-3

SECTION VIII. (Sub-section 430) Wastewater Valves and Appurtenances. 1. General thru Gate Valves thru 430-3 SECTION VIII (Sub-section 430) Wastewater Valves and Appurtenances Article Page 1. General 430-1 thru 430-2 2. Gate Valves 430-2 thru 430-3 3. Plug Valves 430-3 thru 430-4 4. Check Valves 430-4 5. Tapping

More information

VERTICAL LIFT FIRE/BLAST DOORS

VERTICAL LIFT FIRE/BLAST DOORS International Door, Inc. 8001 Ronda Drive Canton, MI 48187 (800) 231-9521 Website: www.international-door.com Sales Dept. E-Mail: sales@international-door.com Engineering Dept. E-Mail: engineering@international-door.com

More information

Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION. Packaged Pump Sets for Diesel/Fuel Oil Application Page 1

Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION. Packaged Pump Sets for Diesel/Fuel Oil Application Page 1 Packaged Pump Sets for Diesel/Fuel Oil Application Page 1 Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION Packaged Pump Sets for Diesel/Fuel Oil Application Page 2 Description Simplex SPS Series Packaged

More information

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2015 edition of, to the 2015 International Fire Code (). Please note that

More information

Tank Filling Systems for Petroleum Products

Tank Filling Systems for Petroleum Products for Petroleum Products Insight Onsite for Petroleum Products Page 2 What is it used for? Generally used with aboveground storage tanks, although some underground uses as well. What is it? An easy means

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

PREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843

PREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843 BID ADDENDUM NO. 1 PROJECT: PREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843 LABELLA PROJECT NO: 2160128 DATE: FEBRUARY 11, 2016 FROM: LaBella

More information

The cost estimation methodology used to update the charges and credits is the same methodology the Company utilized in the prior year s filing.

The cost estimation methodology used to update the charges and credits is the same methodology the Company utilized in the prior year s filing. LISA D. NORDSTROM Lead Counsel lnordstrom@idahopower.com December 28, 2018 Public Utility Commission of Oregon Filing Center 201 High Street SE, Suite 100 P.O. Box 1088 Salem, Oregon 97301 Re: Tariff Advice

More information

Air Curtain. Installation, Operating and Maintenance Instructions

Air Curtain. Installation, Operating and Maintenance Instructions Installation, Operating and Maintenance Instructions Save this manual for future reference. Air Curtain Model Numbers: ES026, ES036, ES042, ES048, ES060, ES072 READ THIS OWNER S MANUAL CAREFULLY BEFORE

More information

PUBLIC WORKS AND SERVICES PETROLEUM PRODUCTS DIVISION STANDARD DETAILED DRAWINGS FOR NORTHERN FUEL STORAGE AND DISTRIBUTION FACILITIES

PUBLIC WORKS AND SERVICES PETROLEUM PRODUCTS DIVISION STANDARD DETAILED DRAWINGS FOR NORTHERN FUEL STORAGE AND DISTRIBUTION FACILITIES PUBLIC WORKS AND SERVICES PETROLEUM PRODUCTS DIVISION STANDARD DETAILED DRAWINGS FOR NORTHERN FUEL STORAGE AND DISTRIBUTION FACILITIES 3rd EDITION - 01/2006 Foreword This publication, together with the

More information

SECTION MOTOR REQUIREMENTS for HVAC

SECTION MOTOR REQUIREMENTS for HVAC PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life

More information

Series CC Condensate Units

Series CC Condensate Units Bulletin S-215F Series CC Condensate Units Simplex or Duplex 1,000 thru 15,000 sq. ft. EDR 250 thru 7,500 lb./hr. Cast Iron Receivers: for years of dependable service; warranted for 20 years from date

More information

December 13, This document was filed with the Board of Public Utilities on December 13, It is awaiting final approval by BPU staff.

December 13, This document was filed with the Board of Public Utilities on December 13, It is awaiting final approval by BPU staff. JERSEY CENTRAL POWER & LIGHT UNIFORM TECHNICAL AND PROCEDURAL INTERCONNECTION REQUIREMENTS FOR NET METERING FACILITIES FOR INVERTER BASED WIND AND PHOTOVOLTAIC SYSTEMS OF 100 kw OR SMALLER for Atlantic

More information

ADDENDUM NO. 2 DATE: March 3, BID TITLE: Replacement of Two (2) Twenty Ton Overhead Crane Hoists, Trolley Packages, and Associated Equipment

ADDENDUM NO. 2 DATE: March 3, BID TITLE: Replacement of Two (2) Twenty Ton Overhead Crane Hoists, Trolley Packages, and Associated Equipment FLORIDA DEPARTMENT OF TRANSPORTATION Procurement Office 605 Suwannee Street, MS 20 Tallahassee, Florida 32399-0450 Phone: (850) 414-4381 Fax: (850) 414-4951 ADDENDUM NO. 2 DATE: March 3, 2016 RE: BID #:

More information

1. Wiring Diagrams: Power, signal, and control wiring.

1. Wiring Diagrams: Power, signal, and control wiring. Page 232123-1 SECTION 232123 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S Revised 04/14/2016 SPECIFICATIONS - DETAILED PROVISIONS Section 16151 - Vertical Hollowshaft Electric Motors C O N T E N T S PART 1 - GENERAL... 1 1.01 SCOPE... 1 1.02 SPECIFIC PROJECT REQUIREMENTS...

More information

CUYAHOGA COUNTY, OHIO ADDENDUM NUMBER 2 FOR THE CLEANING AND TELEVISING OF SEWERS IN VARIOUS COMMUNITIES FOR A TWO-YEAR PERIOD,

CUYAHOGA COUNTY, OHIO ADDENDUM NUMBER 2 FOR THE CLEANING AND TELEVISING OF SEWERS IN VARIOUS COMMUNITIES FOR A TWO-YEAR PERIOD, CUYAHOGA COUNTY, OHIO ADDENDUM NUMBER 2 FOR THE CLEANING AND TELEVISING OF SEWERS IN VARIOUS COMMUNITIES FOR A TWO-YEAR PERIOD, 2017-2018 FOR THE CUYAHOGA COUNTY DEPARTMENT OF PUBLIC WORKS RQ# 39104 BIDS

More information

Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS

Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS INSTALLATION INSTRUCTIONS UNIVERSAL VALVE COMPANY, INC. 478 SCHILLER ST. ELIZABETH, NJ 07206 Rev A

More information

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2008 edition of NFPA 30A, and the 2006 International Fire Code (IFC). Please

More information

SOUND-RETARDANT- VERTICAL LIFT DOORS

SOUND-RETARDANT- VERTICAL LIFT DOORS International Door, Inc. 8001 Ronda Drive Canton, MI 48187 (800) 231-9521 Website: www.international-door.com Sales Dept. E-Mail: sales@international-door.com Engineering Dept. E-Mail: engineering@international-door.com

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not

More information

Provide the following information: Site Address: City: Zip: Project Contact Name: Phone No.: ( ) ext.

Provide the following information: Site Address: City: Zip: Project Contact Name: Phone No.: ( ) ext. UNDERGROUND STORAGE TANK SYSTEM INSTALLATION/UPGRADE SUPPLEMENT For use by Unidocs Member Agencies or where approved by your Local Jurisdiction Authority Cited: California Fire (CFC); Chapter 6.7, Health

More information

SECTION FACILITY FUEL OIL PIPING

SECTION FACILITY FUEL OIL PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

UNIVERSITY OF CALIFORNIA, SAN DIEGO

UNIVERSITY OF CALIFORNIA, SAN DIEGO BERKELEY DAVIS IRVINE LOS ANGELES MERCED RIVERSIDE SAN DIEGO SAN FRANCISCO SANT A BARBARA SANT A CRUZ OFFICE OF THE ASSIST ANT VICE CHANCELLOR 9500 GILMAN DRIVE #0916 CAMPUS ARCHITECT- FACILITIES DESIGN

More information

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation Deluge Valve DV-5 Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation GeneralDescription The Model DV-5 Deluge Valve (described in Technical

More information

9.21 Tank Program Guide NYS Office of Mental Health Tank System Installation Guide

9.21 Tank Program Guide NYS Office of Mental Health Tank System Installation Guide - Design Guides A. SITE PLANS: Provide existing condition, removal plan, and proposed installation site plans for all tanks. Plans must include the following: 1. Dimensions of tank and any structural pads.

More information

7 Single Family Service

7 Single Family Service 7 Single Family Service 7. General The location of the service entrance on the Customer s premises is an important consideration. For clearance and location information see section 5 (Clearances). Consult

More information

City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems <48kW)

City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems <48kW) City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems

More information

East Central College

East Central College SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Wall switches. b. Receptacles c. Device plates and decorative box covers. 1.2 RELATED

More information

4 FEET HIGH CHAIN LINK FENCE AND GATE. TO INCLUDE TOP RAIL AND ALL OTHER HARDWARE, POSTS, ETC. NOT INCLUDED BELOW.

4 FEET HIGH CHAIN LINK FENCE AND GATE. TO INCLUDE TOP RAIL AND ALL OTHER HARDWARE, POSTS, ETC. NOT INCLUDED BELOW. 4 FEET HIGH CHAIN LINK FENCE AND GATE. TO INCLUDE TOP RAIL AND ALL OTHER HARDWARE, POSTS, ETC. NOT INCLUDED SIGNED BID / SIGNED ADDENDUM Yes / Yes Yes / Yes Yes / Yes YEARS EXPERIENCE 25 Years 24 Years,

More information

Downloaded from

Downloaded from December 20, 1989 TO SUPERSEDE W-F-408D 30 March 1984 FEDERAL SPECIFICATION FITTINGS FOR CONDUIT, METAL, RIGID (THICK-WALL AND THIN-WALL (EMT) TYPE) This specification is approved by the Commissioner.

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS 834.1 DESCRIPTION: This item shall consist of fire hydrant installations using joint restraints in accordance

More information

SPC-PANEL Simplex, Single Phase Pump Control Panel

SPC-PANEL Simplex, Single Phase Pump Control Panel Pump Installation and Service Manual SPC-PANEL Simplex, Single Phase Pump Control Panel Pump Controls for 2 HP Grinder Pumps NOTE! To the installer: Please make sure you provide this manual to the owner

More information

SECTION GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT

SECTION GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT SECTION 22 05 12 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable in the section

More information

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST Date Documents Submitted: Log No.: File No.: Plan Examiner: Permit No.: Property Information Building Name: Building Address: Building Manager's Name: Building Manager's Phone: Fax: System Designer/Contractor

More information

DELETE first sentence of first paragraph that reads: REPLACE with the following:

DELETE first sentence of first paragraph that reads: REPLACE with the following: To Bidder of Record: SAN ANTONIO WATER SYSTEM Addendum 2 To Construction Documents For 2012 WATER & SEWER CONSTRUCTION CONTRACT, PACKAGE I SAWS WATER JOB NO. 12-5001 SAWS SEWER JOB NO. 12-5501 Solicitation

More information

SPECIAL SPECIFICATION 8676 Solar Panel Power Supply System

SPECIAL SPECIFICATION 8676 Solar Panel Power Supply System 2004 Specifications CSJ 2552-01-033 SPECIAL SPECIFICATION 8676 Solar Panel Power Supply System 1. Description. This work shall consist of furnishing and installing an integrated Solar Panel Power Supply

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

SAN ANTONIO WATER SYSTEM PURCHASING DEPARTMENT

SAN ANTONIO WATER SYSTEM PURCHASING DEPARTMENT SAN ANTONIO WATER SYSTEM PURCHASING DEPARTMENT Issued By: Joseph Ramon Date Issued: July 29, 2014 BID NO.: 14-5053 FORMAL INVITATION FOR BIDS ANNUAL CONTRACT FOR PUMP REPAIRS SUBMERSIBLE TRAINS AND CENTRIFUGAL

More information

For Reference Only. Jett Pro Line Maintenance FAA REPAIR STATION NO. YUJR093Y EUROPEAN AVIATION SAFETY AGENCY (EASA) MANUAL SUPPLEMENT

For Reference Only. Jett Pro Line Maintenance FAA REPAIR STATION NO. YUJR093Y EUROPEAN AVIATION SAFETY AGENCY (EASA) MANUAL SUPPLEMENT FAA REPAIR STATION NO. YUJR093Y EUROPEAN AVIATION SAFETY AGENCY (EASA) MANUAL SUPPLEMENT EASA SUPPLEMENT TO FAA CFR PART 145 Approval Certificate EASA 145.5952 Compliance with this EASA Manual Supplement

More information

DIVISION 311 MISCELLANEOUS ELECTRICAL RULES

DIVISION 311 MISCELLANEOUS ELECTRICAL RULES DIVISION 311 MISCELLANEOUS ELECTRICAL RULES 918-311-0000 Design, Planning and Lay Out of Electrical Installations by Supervising Electricians A licensed supervising electrician may design, plan and lay

More information

1. GENERAL BIDDING: For clarification, the sealed bids shall be marked as follows:

1. GENERAL BIDDING: For clarification, the sealed bids shall be marked as follows: Addendum Santa Fe College Y Building Learning Commons Renovations and Remodel Gainesville, Florida Project 18-24-22 October 22, 2018 SF Project Number Date 1763 Page 1 of 2 and 3 Attachments Architect

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 23 30 00 - HVAC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01 00, "Mechanical

More information

SECTION HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS

SECTION HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS SECTION 08350 HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1

More information

SUGGESTED SPECIFICATIONS Pump Frames NS3 thru OMC5

SUGGESTED SPECIFICATIONS Pump Frames NS3 thru OMC5 SOLIDS-HANDLING WASTEWATER PUMPS Pump Frames NS3 thru OMC5 GENERAL Furnish and install Vertical Closed-Shaft Wet-Pit Pumping Units complete with all accessories and appurtenances as shown in the plans

More information

ADDENDUM NO. #1 ITB # FLORIDA A&M UNIVERSITY (FAMU) FUEL STORAGE TANK INSPECTIONS December 8, 2017

ADDENDUM NO. #1 ITB # FLORIDA A&M UNIVERSITY (FAMU) FUEL STORAGE TANK INSPECTIONS December 8, 2017 ADDENDUM NO. #1 ITB #0003-2018 FLORIDA A&M UNIVERSITY (FAMU) FUEL STORAGE TANK INSPECTIONS December 8, 2017 ITB Services: Subject: The purpose of this solicitation is to acquire sealed competitive bids

More information

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents. PART 1: GENERAL 1.01 This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the

More information

TERMS AND CONDITIONS

TERMS AND CONDITIONS XXV. NET METERING A. Applicability and Availability 1. The terms Net Metering Service, Demand Charge-based Time-of- Use Tariff, Net Metering Customer, Customer, Time-of-Use Customer, Time-of-Use Tier,

More information

Eagle Mountain-Saginaw Independent School District REQUEST FOR COMPETITIVE SEALED PROPOSALS (RFCSP)

Eagle Mountain-Saginaw Independent School District REQUEST FOR COMPETITIVE SEALED PROPOSALS (RFCSP) Eagle Mountain-Saginaw Independent School District REQUEST FOR COMPETITIVE SEALED PROPOSALS (RFCSP) RFCSP Number: 1718-005-2023 RFCSP Title: Cabling Infrastructure Job Order Contract Due Date: February

More information

ADDENDUM #2 TO BID # BID NUMBER: ISSUE DATE: Friday, January 18, 2019

ADDENDUM #2 TO BID # BID NUMBER: ISSUE DATE: Friday, January 18, 2019 Georgetown County, South Carolina 129 Screven Street, Suite 239 Post Office Drawer 421270 Georgetown, SC 29442-4200 (843) 545-3083 Fax (843) 545-3500 E-Mail purch@gtcounty.org Website http://www.gtcounty.org

More information

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT SECTION 230513 - COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Single phase electric motors. B. Three phase electric motors. 1.2 REFERENCE STANDARDS A. ABMA STD 9

More information

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016 DISTRIBUTED GENERATION CHAPTER 5 500. SCOPE This chapter includes distributed or customer-owned generation connected in parallel and operating with Alliant Energy s electric distribution system. For all

More information

490 Series Actuators. 490 Series. Contents. Introduction

490 Series Actuators. 490 Series. Contents. Introduction Instruction Manual Form 049 May 1992 490 Series 490 Series Actuators Contents Introduction.............................. 1 Scope of Manual............................. 1 Description..................................

More information

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Special Specification 6058 Battery Back-Up System for Signal Cabinets Special Specification Battery Back-Up System for Signal Cabinets 1. DESCRIPTION 2. DEFINITIONS Install a Battery Back-Up System (BBU System) for traffic signals that will provide reliable emergency power

More information

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual Model AM2 M40 Panel Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately to the

More information

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party

More information

COMMERCIAL QUICK REFERENCE

COMMERCIAL QUICK REFERENCE COMMERCIAL QUICK REFERENCE PROVO CITY POWER STANDARDS ELECTRICAL ENGINEERING UPDATED: 2016 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION. 18" MIN. OF TAIL. (NEUTRAL CONDUCTOR MUST BE WHITE OR

More information

Installation & Maintenance Manual Green Machine PMC / ISD California

Installation & Maintenance Manual Green Machine PMC / ISD California Installation & Maintenance Manual Green Machine PMC / ISD California Revision 1.12 Vapor Systems Technologies, Inc. 650 Pleasant Valley Drive Springboro, Ohio 45066 (937) 704 9333 PH (937) 704 9443 FX

More information

SECTION ENCLOSED CONTROLLERS

SECTION ENCLOSED CONTROLLERS SECTION 16420 ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

New Panelboard for Lot H, EV Charger Energization, Las Positas College. Scope of Work and Technical Specifications

New Panelboard for Lot H, EV Charger Energization, Las Positas College. Scope of Work and Technical Specifications CHABOT-LAS POSITAS COMMUNITY COLLEGE DISTRICT New Panelboard for Lot H, EV Charger Energization, Las Positas College Scope of Work and Technical Specifications Chabot-Las Positas Community College District

More information

EMERGENCY GENERATOR SET

EMERGENCY GENERATOR SET PART 8.1: EMERGENCY GENERATOR SET PART 1 - GENERAL I SCOPE A. This specification covers the design, furnishing, installation and start up of a factory built, production tested, operable, liquid cooled

More information

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt. ME3H SUMP/EFFLUENT PUMP ME3F SUMP/EFFLUENT PUMP ME3H/ME3F SERIES SUBMERSIBLE SUMP AND EFFLUENT PUMPS INSTALLATION AND SERVICE MANUAL Automatic and manual models. Single phase power only 115 or 230 volt.

More information

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible

More information

Kitchen Tech Series Air Curtain

Kitchen Tech Series Air Curtain Installation, Operating, and Maintenance Instructions Save this manual for future reference. Kitchen Tech Series Air Curtain Model Numbers: KTECH026, KTECH036, KTECH042, KTECH048, KTECH060, KTECH072, KTECH084,

More information

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM Page 1 of 19 Table of Contents 1.0 SCOPE...4 2.0 PURPOSE...4 3.0 LIMITATIONS...5 4.0 GENERAL INTERCONNECTION

More information

AGREEMENT. done at Vienna on 13 November Addendum 1: Rule No. 1. Revision 1

AGREEMENT. done at Vienna on 13 November Addendum 1: Rule No. 1. Revision 1 6 March 2007 AGREEMENT CONCERNING THE ADOPTION OF UNIFORM CONDITIONS FOR PERIODICAL TECHNICAL INSPECTIONS OF WHEELED VEHICLES AND THE RECIPROCAL RECOGNITION OF SUCH INSPECTIONS done at Vienna on 13 November

More information

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

Installation and Maintenance Instructions 44TA Liquid Level Float Switch OPW Installation, Operation and Maintenance Manual, Page 54 MPORTANT: Please read these warnings and use the assembly instructions completely and carefully before starting. Failure to do so may cause product

More information

SOUTH HADLEY ELECTRIC LIGHT DEPARTMENT Net Metering Policy As Amended 03/23/16 By the South Hadley Municipal Light Board

SOUTH HADLEY ELECTRIC LIGHT DEPARTMENT Net Metering Policy As Amended 03/23/16 By the South Hadley Municipal Light Board SOUTH HADLEY ELECTRIC LIGHT DEPARTMENT Net Metering Policy As Amended 03/23/16 By the South Hadley Municipal Light Board Policy Description: In an effort to ensure fair treatment of all of its customers,

More information

REQUEST FOR QUOTATION

REQUEST FOR QUOTATION REQUEST FOR QUOTATION PORTABLE GENERATOR RESPONSE DUE: Thursday, April 18, 2019, at 4:00 pm Request for Quotation SCOPE AND OBJECTIVES: The ( District ) will be accepting quotes from authorized Multiquip

More information

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS Presented by: Joyce A. Rizzo President JD2 Environmental, Inc. 800 East Washington Street West Chester, PA 19380 www.jd2env.com

More information

September 22, 2016 To: All Contractors Re: Boiler Back-Up Fuel Tank System Renovation. Dear Sir:

September 22, 2016 To: All Contractors Re: Boiler Back-Up Fuel Tank System Renovation. Dear Sir: Mount Allison University Addendum #1 Section 00 91 00 Boiler Back-Up Fuel Tank System Renovation Page 1 of 5 Project # HEAT-15-02 September 22 2016 September 22, 2016 To: All Contractors Re: Boiler Back-Up

More information

PATTERSON PUMP COMPANY

PATTERSON PUMP COMPANY PATTERSON PUMP COMPANY A Gorman Rupp Company JOCKEY PUMP CONTROLLERS UL508 LISTED ETL LISTED FEB 013 Patterson Jockey Pump controllers are built to NEMA industrial standards and are UL508 listed and ETL

More information

FUEL MANAGEMENT SYSTEM SentryGOLD INSTALLATION MANUAL

FUEL MANAGEMENT SYSTEM SentryGOLD INSTALLATION MANUAL FUEL MANAGEMENT SYSTEM SentryGOLD INSTALLATION MANUAL TRAK SentryGOLD Installation Manual rev.03 4-18-2014 IMPORTANT The SentryGOLD and associated equipment will be installed in close proximity to combustible

More information

Utility Distribution System

Utility Distribution System READ AND SAVE THESE INSTRUCTIONS Utility Distribution System Installation, Operation and Maintenance Manual Warning!! Improper installation, adjustment, alteration, service or maintenance can cause property

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS 834.1 DESCRIPTION: This item shall consist of fire hydrant installations using joint restraints in accordance

More information

OPTIONS. Catalog Number (July. 2017) The content herein is subject to change without notification. OP-1

OPTIONS. Catalog Number (July. 2017) The content herein is subject to change without notification. OP-1 OPTIONS Catalog Number 0011.0 (July. 2017) OP-1 RECOMMENDED OPTIONS RECOMMENDED OPTIONAL ACCESSORIES The following optional equipment is recommended for most fuel systems with pump(s) and motor(s): 360

More information