A&A CONSULTANTS, INC Pine Hollow Road McKees Rocks, PA 15136

Size: px
Start display at page:

Download "A&A CONSULTANTS, INC Pine Hollow Road McKees Rocks, PA 15136"

Transcription

1 A&A CONSULTANTS, INC Pine Hollow Road McKees Rocks, PA Telephone: (412) Fax: (412) Civil, Geotechnical & Structural Engineers Ms. Lisa L. Cessna, Executive Director Washington County Planning Commission West Beau Street, Suite 701 Washington, PA February 18, 2016 Subject: Washington County Fairgrounds Entrance Upgrade Geotechnical Summary Report Chartiers Township, Washington County, Pennsylvania A&A Project No Dear Ms. Cessna: A&A Consultants, Inc. (A&A) is pleased to present our Geotechnical Summary Report for the subject project. This report has been prepared in accordance with Contract No RFP-A/E. This report summarizes the test borings, laboratory soil tests, preliminary engineering analyses performed for the proposed structure and presents our findings, conclusions and preliminary recommendations. A&A thanks the Washington County Planning Commission for the opportunity to participate on this project. If you have any questions or require any further assistance, please do not hesitate to contact the undersigned at (412) Very truly yours, A&A Consultants, Inc. Jack T. Roseman, P.E. Senior Geotechnical Engineer Peter M. Dawida, E.I.T. Geotechnical Engineer 1

2 Washington County Fairgrounds Entrance Upgrade Washington County, Pennsylvania Contract # RFP-A/E Geotechnical Summary Report February 18, 2016 Prepared for: Washington County Planning Commission West Beau Street, Suite 701 Washington, PA Prepared by: A&A Consultants, Inc Pine Hollow Road McKees Rocks, PA A&A Project No

3 Table of Contents 1. Scope Geologic Conditions Test Boring Summary Water, Soil and Rock Testing Data Allowable Foundation Types 2 6. Requirements for Future Investigations Necessary to Obtain Foundation Approval... 2 List of Appendices: Appendix A: Engineer s Boring Logs and Core Box Photographs Appendix B: Laboratory Testing Results

4 Geotechnical Summary Report Washington County Fairgrounds Entrance Upgrade Washington County, Pennsylvania Contract # RFP-A/E 1. Scope This report is limited to the preparation of basic subsurface information for the design of the Washington County Fairgrounds Entrance Upgrade, sponsored by the Washington County Planning Commission. The proposed upgrade includes the replacement of an existing bridge structure over an unnamed tributary of Chartiers Creek. The existing bridge superstructure (the bridge deck and raillings) is of a narrow width that becomes a congested pedestrian traffic area during large events at the Fairgrounds. The proposed replacement structure will have a wider deck for better pedestrian capacity. The existing deck will be removed, and the existing substructure (abutments and footings) will remain in place and be reconfigured for the new deck. New substructure will be built upstream of the existing, with the new superstructure extending the full width of the older and newer portions of the substructure. The Geotechnical information will support the new bridge design 2. Geologic Conditions Pittsburgh Formation, Published Information: The Pittsburgh Formation consists of light gray to gray sandstone with medium gray shale and siltstone. It is a Pennsylvanian Age rock that occurs in the Monongahela Group and above the Pittsburgh Coal Seam. Excavation is expected to be difficult. Foundation stability is expected to be good. Weathered rock should be excavated to sound material. There may be a need for under drainage. Field Observations: No scour or other geologic features were noted that will impact the foundation design or construction. Mining Conditions: The Pittsburgh Coal seam has been identified as occurring at a depth of 70 feet beneath the site. Whether the site has been undermined could not be identified from the WPA Mine maps. 3. Test Boring Summary Table 1: Summary of Test Boring Information Boring No. Estimated Ground Surface Elev.¹ (Feet) Depth to Top of Rock (TOR) (Feet) Estimated TOR Elevation (Feet) Average SPT N60 First 10 Ft. Average SPT N60 ² 10 Ft. to 20 Ft. (or TOR) Average Core Recovery Average Core RQD Estimated 0-Hour Ground Water Elevation Estimated 24-Hour Ground Water Elevation B NR B NR 1 The Estimated Ground Surface Elevation is for general information only and is not to be used for design or construction. Elevations were estimated using nearby surveyed values. 2 N-values do not include split-barrel sampler refusal at the top of rock, NR Not recorded, grouted upon completion. 1

5 4. Water, Soil and Rock Testing Data Table 2: Summary of Laboratory Testing of Soil Boring Classification No. Sample Depth (Feet) Origin of Sample AASHTO USCS Natural Moisture Content LL PL B Residual A-2-4(0) SC B Residual A-7-6(15) CL Table 3: Summary of Unconfined Compressive Strength of Rock Boring Core Run Rock Type Depth (Feet) Failure Type No. Number B-1 R-2 Clayshale Perpendicular 2,903 Uniaxial Compressive Strength, Co (psi) PI 5. Allowable Foundation Types General Discussion: Spread footings bearing on existing fill, high plasticity soils, coal or slaking bedrock are not allowable for any substructure unit. a. Spread footings on soil: allowable but existing fill must be over-excavated and replaced with structural fill. b. Spread footings on rock: feasible, but bedrock may be too deep c. Drilled Shafts: allowable d. Point or End Bearing Piles Driven to Rock: allowable, PDA required for test piles e. Friction Piles: allowable, PDA required for test piles f. Micropiles to Rock: allowable 6. Requirements for Future Investigations to Obtain Foundation Approval No additional testing is to be required for foundation approval. 2

6 Appendix A Sketch of Boring Locations Typed Engineer s Logs

7 COUNTY FAIRGROUNDS BORE LOCATIONS AT WHITE STAKES TROLLEY MUSEUM WASHINGTON COUNTY FAIRGROUNDS ENTRANCE PROJECT GEOTECHNICAL BORING LOCATIONS A&A CONSULTANTS

8 PENNDOT ENGINEER'S LOG - PENNDOT GINT GDT - 2/16/16 16:07 - P:\_P\433 WASHINGTON FAIRGROUNDS\GEOTECH\WASHINGTON FAIRGROUNDS LOGS.GPJ Boring B-1 ECMS District: 12 County: Washington SR County Fairgrounds Section Baseline: Sta. Offset Segment Offset Coordinates: Lat. Long. N E Ground Elev ft. Water Level Elev./Elapsed Time: Initial ft. Elapsed 0.0 hr. Final NR Elapsed NR Driller: Dustin Earlywine Company: Test Boring Services, Inc. ELEV GRAPHIC MATERIAL DESCRIPTION COMMENTS - OBSERVATIONS ASPHALT. 0.5'/El SILT, some Sand, contains rock fragments, stiff, moist, homogeneous, brown, fill. 9.0'/El CLAY and SAND, some Gravel, little Silt, soft to stiff, wet to moist, homogeneous, gray, residuum. 12.0'/El CLAY, trace Sand, trace Silt, contains rock fragments, dense to very dense, moist to dry, homogeneous, gray, residuum. ENGINEER'S LOG Drilling Start: 01/12/ :00 am Drilling Complete: 01/12/ :00 pm Grouting Complete: Rig: Track Rig w/safety Hammer Hammer Type: Safety SPT Hammer Efficiency: Assumed 0.6 Hammer Calibration Date: Hole Type: Continuous SPT - Rock Core Casing Type: Hollow Stem Auger Casing I.D.: 3.25 in. Casing Depth: 13.5 ft. Dble Tube Wire Ln-NQ Rock Core Method: Inspector: Peter Dawida Inspector Cert. No '/El AASHTO / USCS a-4 / ml A-2-4 / SC Measured DEPTH SAMPLE No. A- S-1 S-2 S-3 S-4 S-5 S-6 S-7 S-8 S-9 A- S-10 R-1 BLOW COUNTS (Blows/ 0.5ft) /.4' 50/.4' Final Log Checked and Approved By: Jack Roseman Date: 1/21/ % Sheet 1 of 2 PG/PE Seal, Signature and Date NOTE: N values and all graphical plots are for information only. N RQD % REC (ft.) REC RQD % Soil/Rock Rec.% SPT (N)

9 ENGINEER'S LOG Boring B-1 ECMS District: 12 County: Washington SR County Fairgrounds Section Sta. Offset Sheet 2 of 2 NOTE: N values and all graphical plots are for information only. ELEV. GRAPHIC MATERIAL DESCRIPTION COMMENTS - OBSERVATIONS CLAYSTONE interbedded with SHALE, gray, soft to medium hard, moderately weathered to slightly weathered, moderate to medium bedding with flat dip, (RQD=31%). AASHTO / USCS DEPTH 15 SAMPLE No. R-1 BLOW COUNTS (Blows/ 0.5ft) N RQD % 44% REC (ft.) 3.0 REC RQD % Soil/Rock Rec.% SPT (N) (Layer continued from the previous page.) PENNDOT ENGINEER'S LOG - PENNDOT GINT GDT - 2/16/16 16:07 - P:\_P\433 WASHINGTON FAIRGROUNDS\GEOTECH\WASHINGTON FAIRGROUNDS LOGS.GPJ Bottom of boring. 23.9'/El R-2 R-3 34% 15%

10 PENNDOT ENGINEER'S LOG - PENNDOT GINT GDT - 2/16/16 16:07 - P:\_P\433 WASHINGTON FAIRGROUNDS\GEOTECH\WASHINGTON FAIRGROUNDS LOGS.GPJ Boring B-2 ECMS District: 12 County: Washington SR County Fairgrounds Section Baseline: Sta. Offset Segment Offset Coordinates: Lat. Long. N E Ground Elev ft. Water Level Elev./Elapsed Time: Initial ft. Elapsed 0.0 hr. Final NR Elapsed NR Driller: Dustin Earlywine Company: Test Boring Services, Inc. ELEV GRAPHIC MATERIAL DESCRIPTION COMMENTS - OBSERVATIONS Crushed Stone (Subbase). 1.5'/El SILT, some Sand, little Clay, stiff, moist, homogeneous, brown, fill. 6.0'/El CLAY and SILT, little Sand, soft to stiff, wet, homogeneous, gray, residuum. 7.8'/El CLAY, contains rock fragments, very dense, dry, homogeneous, gray, residuum. 8.5'/El CLAYSTONE interbedded with SHALE, gray, soft to medium hard, weathered to slightly weathered, moderate to medium bedding with flat dip, (RQD=39%). ENGINEER'S LOG Drilling Start: 01/12/2016 8:00 am Drilling Complete: 01/12/ :00 am Grouting Complete: Rig: Track Rig w/safety Hammer Hammer Type: Safety SPT Hammer Efficiency: Assumed 0.6 Hammer Calibration Date: Hole Type: Continuous SPT - Rock Core Casing Type: Hollow Stem Auger Casing I.D.: 3.25 in. Casing Depth: 9 ft. Dble Tube Wire Ln-NQ Rock Core Method: Inspector: Peter Dawida Inspector Cert. No AASHTO / USCS a-1-a / gp a-4 / ml A-7-6 / CL Measured DEPTH SAMPLE No. S-1 S-2 S-3 S-4 S-5 S-6 S-7 R-1 R-2 BLOW COUNTS (Blows/ 0.5ft) /.2' Final Log Checked and Approved By: Jack Roseman Date: 1/21/ % 31% Sheet 1 of 2 PG/PE Seal, Signature and Date NOTE: N values and all graphical plots are for information only. N RQD % REC (ft.) REC RQD % Soil/Rock Rec.% SPT (N)

11 ENGINEER'S LOG Boring B-2 ECMS District: 12 County: Washington SR County Fairgrounds Section Sta. Offset Sheet 2 of 2 NOTE: N values and all graphical plots are for information only. ELEV. GRAPHIC MATERIAL DESCRIPTION COMMENTS - OBSERVATIONS CLAYSTONE interbedded with SHALE, gray, soft to medium hard, weathered to slightly weathered, moderate to medium bedding with flat dip, (RQD=39%). AASHTO / USCS DEPTH 15 SAMPLE No. R-2 BLOW COUNTS (Blows/ 0.5ft) N RQD % 31% REC (ft.) 5.0 REC RQD % Soil/Rock Rec.% SPT (N) (Layer continued from the previous page.) PENNDOT ENGINEER'S LOG - PENNDOT GINT GDT - 2/16/16 16:07 - P:\_P\433 WASHINGTON FAIRGROUNDS\GEOTECH\WASHINGTON FAIRGROUNDS LOGS.GPJ Bottom of boring. 19.7'/El R-3 37% 2.2

12 Appendix B Laboratory Testing Results

13 PARTICLE-SIZE ANALYSIS OF SOILS - ASTM D422 Client A&A Consultants, Inc. Boring B-1 Client Project Washington County Fairgrounds Depth 10.5'-12.0' Project No Sample S-8 Lab Sample Sample Color: OLIVE BROWN USCS Group Name: CLAYEY SAND WITH GRAVEL USCS Group Symbol: SC USDA: SANDY LOAM AASHTO: A-2-4 (0) MECHANICAL SIEVE Total Sample Sieve Nominal Dry Split Normalized Project Total Sample Wet Wt, gm (-3") 412 Size Opening, mm Wt, gm % Retained % Finer Specifications Sample Split on Sieve No. 4 3" %.0% Coarse Washed Dry Sample, gm /2" %.0% Wet Wt Passing Split, gm 308 2" %.0% Dry Wt. Passing Split, gm /2" %.0% Total Sample Dry Wt, gm 362 1" %.0% % 3/4" % 91.9% Split Sample - Passing No. 4 1/2" % 84.2% Tare No /8" % 81.2% Tare + WS., gm No % 71.2% Tare + DS., gm No % 61.6% Tare, gm No % 50.5% Water Content of Split Sample 19.5% No % 44.7% Wt. of DS., gm No % 39.9% No % 30.6% Wt. of +#200 Sample, gm No % 28.1% HYDROMETER (-#200) Tare No. 542 Wt. Dispers., gm 5 Specific Gravity 2.7 Wt. Tare + DS., gm Wt. Dry Soil, gm (-#200 ) Assumed Wt. Tare, gm #10 Dispersed 1min in Hamilton Beach Mixer a Factor Elapsed R Temp Composite R Percent Particle Adjusted Time Measured *C Correction Corrected K Factor Finer Diameter % Finer (min.) (mm) % % % % % % % USCS SOIL CLASSIFICATION USDA CLASSIFICATION Corrected For % Passing a 3" Sieve % Gravel (-3" & +#4) 28.8 Silt=15.1% Clay=13% Particle Percent Percent of Corrected Coarse=8.1; Fine=20.7 D60, mm NA Size Finer Each Component Percent of % Sand (-#4 & +#200) 43.1 D30, mm NA (mm) (Material) -2.0 mm Coarse=9.6; Medium=16.9; Fine=16.5 D10, mm NA Material % Fines (-#200) 28.1 Cc NA for USDA % Plus #200 (-3") 71.9 Cu NA Gravel USCS Description CLAYEY SAND WITH GRAVEL Sand USCS Group Symbol Atterberg Limits Group Symbol SC CL - LEAN CLAY Silt Auxiliary Information Wt Ret, gm % Retained % Finer " Sieve mm Clay " Sieve mm USDA Classification 3" Sieve - 75 mm SANDY LOAM Input Validation Yes Reviewed By: SVG Date Tested 1/14/2016 COPYRIGHT 2015 GEOTECHNICAL TESTING SERVICES INC

14 Plasticity Index Water Content PI = 10 LIQUID LIMIT, PLASTIC LIMIT, AND PLASTICITY INDEX OF SOILS ASTM D 4318 Client A&A Consultants, Inc. Boring B-1 Client Project Washington County Fairgrounds Depth 10.5'-12.0' Project No Sample S-8 Lab Sample Soil Description: OLIVE BROWN LEAN CLAY (-#40 Fraction) AS-RECEIVED W.C. SAMPLE SUMMARY Activity Index = 1.12; Liquidity Index = -.15 Tare Number 2011 Liquid Limit (LL), % 31 Wt. Tare & WS, gm Plastic Limit (PL), % 21 Wt. Tare & DS, gm Plasticity Index (PI) 10 Wt. Tare, gm USCS Group Symbol (-#40 Fraction ) CL Water Content, % 19.5 USCS Group Name (-#40 Fraction ) LEAN CLAY Sample Color: OLIVE BROWN PLASTIC LIMIT LIQUID LIMIT Points Run Tare Number Points Point Wt. Tare & WS, gm Wt. Tare & DS, gm Wt. Tare, gm Water Content, % # of Blows pt adj. WC 31.5 PLASTICITY CHART FLOW CURVE 60 YES NO NO Blows Log WC YES CH - Fat YES Clay YES 1 Pt = wc*(blow LL = pt avg CL Lean Clay LL 31 Slope #DIV/0! PL = Intercept 21 #DIV/0! Blows 25 NMC = MH - Elastic Silt CL-ML ML - Silt Liquid Limit No. of Blows Input Validation: Yes Reviewed By: SVG Date Tested: 1/14/2016 COPYRIGHT 2015 GEOTECHNICAL TESTING SERVICES INC

15 Percent Finer PARTICLE-SIZE ANALYSIS OF SOILS - ASTM D422 Client A&A Consultants, Inc. Boring B-1 Client Project Washington County Fairgrounds Depth 10.5'-12.0' Project No Sample S-8 Lab Sample Sample Color: OLIVE BROWN USCS Group Name: CLAYEY SAND WITH GRAVEL USCS Group Symbol: SC USDA: SANDY LOAM AASHTO: A-2-4 (0) % 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 10 USCS SOIL CLASSIFICATION Corrected For % Passing a 3" Sieve US Std. Particle Percent Sieve Diameter Finer Size (mm) 3" 75.0% 2-1/2" 63.0% 2" 50.0% 1-1/2" % 1" 25.0% 3/4" % 1/2" % 3/8" % No % No % No % No % No % No % No % NA % NA % NA % NA % NA % NA % NA % USDA CLASSIFICATION % Gravel (-3" & +#4) 28.8 Silt=15.1% Clay=13% Particle Percent Percent of Corrected Coarse=8.1; Fine=20.7 D60, mm NA Size Finer Each Component Percent of % Sand (-#4 & +#200) 43.1 D30, mm NA (mm) (Material) -2.0 mm Coarse=9.6; Medium=16.9; Fine=16.5 D10, mm NA Material % Fines (-#200) 28.1 Cc NA for USDA % Plus #200 (-3") 71.9 Cu NA Gravel USCS Description CLAYEY SAND WITH GRAVEL Sand USCS Group Symbol Atterberg Limits Group Symbol SC CL - LEAN CLAY Silt Auxiliary Information Wt Ret, gm % Retained % Finer " Sieve mm Clay " Sieve mm " Sieve - 75 mm Diameter, mm USDA Classification SANDY LOAM COPYRIGHT 2015 GEOTECHNICAL TESTING SERVICES INC

16 USDA CLASSIFICATION CHART Client A&A Consultants, Inc. Boring B-1 Client Project Washington County Fairgrounds Depth 10.5'-12.0' Project No Sample S-8 Lab Sample Sample Color: OLIVE BROWN USCS Group Name: CLAYEY SAND WITH GRAVEL USCS Group Symbol: SC USDA: SANDY LOAM AASHTO: A-2-4 (0) Corrected for 0% gravel Sand Subsizes Percent Gravel, % 0.0 Corrected Percentages Percent Sand, % 57.6 Very Coarse Sand; Percent Silt, % 27.9 Coarse Sand; Percent Clay, % 14.5 Medium Sand; Fine Sand; Very Fine Sand; Total 57.6 % Clay 0 % Silt % CLAY % SILT 50 % Clay SANDY CLAY SANDY CLAY LOAM CLAY CLAY LOAM SILTY CLAY SILTY CLAY LOAM 50 % Silt SANDY LOAM LOAM SILT LOAM SAND LOAMY SAND SILT % Silt % Sand % SAND 50 % Sand 0 % Sand COPYRIGHT 2015 GEOTECHNICAL TESTING SERVICES INC

17 PARTICLE-SIZE ANALYSIS OF SOILS - ASTM D422 Client A&A Consultants, Inc. Boring B-2 Client Project Washington County Fairgrounds Depth 6.0'-7.5' Project No Sample S-5 Lab Sample Sample Color: DARK GRAYISH BROWN USCS Group Name: LEAN CLAY WITH SAND USCS Group Symbol: CL USDA: SILT LOAM AASHTO: A-7-6 (15) MECHANICAL SIEVE Total Sample Sieve Nominal Dry Split Normalized Project Total Sample Wet Wt, gm (-3") 310 Size Opening, mm Wt, gm % Retained % Finer Specifications Sample Split on Sieve No. 4 3" %.0% Coarse Washed Dry Sample, gm 2 2-1/2" %.0% Wet Wt Passing Split, gm 308 2" %.0% Dry Wt. Passing Split, gm /2" %.0% Total Sample Dry Wt, gm 242 1" %.0% % 3/4" %.0% Split Sample - Passing No. 4 1/2" %.0% Tare No /8" % 99.1% Tare + WS., gm No % 99.0% Tare + DS., gm No % 98.0% Tare, gm No % 97.3% Water Content of Split Sample 28.3% No % 96.5% Wt. of DS., gm No % 95.1% No % 86.2% Wt. of +#200 Sample, gm No % 79.9% HYDROMETER (-#200) Tare No. Q53 Wt. Dispers., gm 5 Specific Gravity 2.7 Wt. Tare + DS., gm Wt. Dry Soil, gm (-#200 ) Assumed Wt. Tare, gm #10 Dispersed 1min in Hamilton Beach Mixer a Factor Elapsed R Temp Composite R Percent Particle Adjusted Time Measured *C Correction Corrected K Factor Finer Diameter % Finer (min.) (mm) % % % % % % % USCS SOIL CLASSIFICATION USDA CLASSIFICATION Corrected For % Passing a 3" Sieve % Gravel (-3" & +#4) 1.0 Silt=47.8% Clay=31.9% Particle Percent Percent of Corrected Coarse=0; Fine=1 D60, mm NA Size Finer Each Component Percent of % Sand (-#4 & +#200) 19.2 D30, mm NA (mm) (Material) -2.0 mm Coarse=1; Medium=1.5; Fine=16.6 D10, mm NA Material % Fines (-#200) 79.9 Cc NA for USDA % Plus #200 (-3") 20.1 Cu NA Gravel USCS Description LEAN CLAY WITH SAND Sand USCS Group Symbol Atterberg Limits Group Symbol CL CL - LEAN CLAY Silt Auxiliary Information Wt Ret, gm % Retained % Finer " Sieve mm Clay " Sieve mm USDA Classification 3" Sieve - 75 mm SILT LOAM Input Validation Yes Reviewed By: SVG Date Tested 1/14/2016 COPYRIGHT 2015 GEOTECHNICAL TESTING SERVICES INC

18 Plasticity Index Water Content PI = 19 LIQUID LIMIT, PLASTIC LIMIT, AND PLASTICITY INDEX OF SOILS ASTM D 4318 Client A&A Consultants, Inc. Boring B-2 Client Project Washington County Fairgrounds Depth 6.0'-7.5' Project No Sample S-5 Lab Sample Soil Description: DARK GRAYISH BROWN LEAN CLAY (-#40 Fraction) AS-RECEIVED W.C. SAMPLE SUMMARY Activity Index =.79; Liquidity Index =.33 Tare Number 2067 Liquid Limit (LL), % 41 Wt. Tare & WS, gm Plastic Limit (PL), % 22 Wt. Tare & DS, gm Plasticity Index (PI) 19 Wt. Tare, gm USCS Group Symbol (-#40 Fraction ) CL Water Content, % 28.3 USCS Group Name (-#40 Fraction ) LEAN CLAY Sample Color: DARK GRAYISH BROWN PLASTIC LIMIT LIQUID LIMIT Points Run Tare Number Points Points Wt. Tare & WS, gm Wt. Tare & DS, gm Wt. Tare, gm Water Content, % # of Blows PLASTICITY CHART FLOW CURVE YES YES YES Blows Log WC LL = 41 YES CH - Fat YES Clay YES 1 Pt = 40 wc*(blow pt avg CL Lean Clay MH - Elastic Silt LL 41 Slope Intercept Blows 25 PL = 22 NMC = 28.3 CL-ML ML - Silt Liquid Limit No. of Blows Input Validation: Yes Reviewed By: SVG Date Tested: 1/14/2016 COPYRIGHT 2015 GEOTECHNICAL TESTING SERVICES INC

19 Percent Finer PARTICLE-SIZE ANALYSIS OF SOILS - ASTM D422 Client A&A Consultants, Inc. Boring B-2 Client Project Washington County Fairgrounds Depth 6.0'-7.5' Project No Sample S-5 Lab Sample Sample Color: DARK GRAYISH BROWN USCS Group Name: LEAN CLAY WITH SAND USCS Group Symbol: CL USDA: SILT LOAM AASHTO: A-7-6 (15) % 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 10 USCS SOIL CLASSIFICATION Corrected For % Passing a 3" Sieve US Std. Particle Percent Sieve Diameter Finer Size (mm) 3" 75.0% 2-1/2" 63.0% 2" 50.0% 1-1/2" % 1" 25.0% 3/4" 19.0% 1/2" % 3/8" % No % No % No % No % No % No % No % NA % NA % NA % NA % NA % NA % NA % USDA CLASSIFICATION % Gravel (-3" & +#4) 1.0 Silt=47.8% Clay=31.9% Particle Percent Percent of Corrected Coarse=0; Fine=1 D60, mm NA Size Finer Each Component Percent of % Sand (-#4 & +#200) 19.2 D30, mm NA (mm) (Material) -2.0 mm Coarse=1; Medium=1.5; Fine=16.6 D10, mm NA Material % Fines (-#200) 79.9 Cc NA for USDA % Plus #200 (-3") 20.1 Cu NA Gravel USCS Description LEAN CLAY WITH SAND Sand USCS Group Symbol Atterberg Limits Group Symbol CL CL - LEAN CLAY Silt Auxiliary Information Wt Ret, gm % Retained % Finer " Sieve mm Clay " Sieve mm " Sieve - 75 mm Diameter, mm USDA Classification SILT LOAM COPYRIGHT 2015 GEOTECHNICAL TESTING SERVICES INC

20 USDA CLASSIFICATION CHART Client A&A Consultants, Inc. Boring B-2 Client Project Washington County Fairgrounds Depth 6.0'-7.5' Project No Sample S-5 Lab Sample Sample Color: DARK GRAYISH BROWN USCS Group Name: LEAN CLAY WITH SAND USCS Group Symbol: CL USDA: SILT LOAM AASHTO: A-7-6 (15) Corrected for 0% gravel Sand Subsizes Percent Gravel, % 0.0 Corrected Percentages Percent Sand, % 24.4 Very Coarse Sand; Percent Silt, % 51.1 Coarse Sand; Percent Clay, % 24.5 Medium Sand; Fine Sand; Very Fine Sand; Total 24.4 % Clay 0 % Silt % CLAY % SILT 50 % Clay SANDY CLAY SANDY CLAY LOAM CLAY CLAY LOAM SILTY CLAY SILTY CLAY LOAM 50 % Silt SANDY LOAM LOAM SILT LOAM SAND LOAMY SAND SILT % Silt % Sand % SAND 50 % Sand 0 % Sand COPYRIGHT 2015 GEOTECHNICAL TESTING SERVICES INC

21 Unconfined Compressive Strength of Intact Rock Core Specimens ASTM D 7012(D 2938 C) / D 4543 Client A&A Consultants, Inc. Boring B-1 Client Project Washington County Fairgrounds Depth 21.3'-21.6' Project Number Sample R-2 Lab ID number Description: Gray Shale As-Received Condition Sample Preparation: Useable L/D < 2 Moisture Preserved Diamond saw blade cut, surface ground flat ASTM D 4543; Section 4.2 & 5.6 Test Parameters Length, in Test Temperature Room Mid Height Diameter #1, in Moisture Condition As-Received Mid Height Diameter #2, in Sample Weight, gms 387 Average Mid. Height Diameter, in Sample Volume, cc 140 Sample Area, in^ Wet Density, pcf 173 L/D Ratio ( ) 1.40 Time to Failure, min 1.42 Loading Rate, psi / sec 35 ASTM D 4543; Section S1 Load Application in Relation to Lithology: Perpendicular Straightness of Specimen Length Peak Load, lbs 9,404 Maximum Gap, in <0.02 Tolerance (<0.02 in) Unconfined Compressive Strength, psi 3,053 Note: L/D does not meet ASTM Requirements ASTM D 4543; Section FP-1 (Flatness and Parallelism) PennDot Specified Correction Factor = ~Distance Reading, " PennDot Specified Corrected Strength = 2,903 along Diameter End 1 D1 End 1 D2 End 2 D1 End 2 D2 Specimen Failure Photo Flatness Pass/Fail Pass Pass Pass Pass End Parallelism Angles Angular difference between End 1 and End 2 - D <0.25* Pass Angular difference between End 1 and End 2 - D <0.25* Pass ASTM D 4543; Section P-2 (End Perpendicularity) Top Bottom Maximum Gap, in 0 0 Angle, * Angle Error (<0.25*) <0.25* Pass <0.25* Pass Input Validation AJD Reviewed By AJD Date Tested 1/26/2016 Copyright 2013 Geotechnical Testing Services, Inc

0 Issued for Information SHS 10/06/16 JAL 10/10/16 JCP 10/10/16

0 Issued for Information SHS 10/06/16 JAL 10/10/16 JCP 10/10/16 Project/Plant: Unit(s): Plant Gorgas Gypsum Pond Units 6-7 Title/Subject: Slope Stability Analysis of Plant Gorgas Gypsum Pond Dam Purpose/Objective: Analyze slope stability of the Plant Gorgas Gypsum

More information

McCALLUM TESTING LABORATORIES, INC.

McCALLUM TESTING LABORATORIES, INC. McCALLUM TESTING LABORATORIES, INC. Geotechnical Engineering, Materials Testing & Environmental Services Crestline Realty Corporation 39 Edwin Drive Virginia Beach, VA 2362 November 29, 11 Attention: Subject:

More information

Soil Stabilization FIELD REPORT WILL FERGUSON. TINDOL CONSTRUCTION 2335 Viggo Road Beeville, Texas 78102

Soil Stabilization FIELD REPORT WILL FERGUSON. TINDOL CONSTRUCTION 2335 Viggo Road Beeville, Texas 78102 2016 Soil Stabilization FIELD REPORT WILL FERGUSON TINDOL CONSTRUCTION 2335 Viggo Road Beeville, Texas 78102 TABLE OF CONTENTS SOIL STABILIZATION FIELD REPORT Overview Page 2 Test Pads Specs of Construction

More information

STATE OF OKLAHOMA DEPARTMENT OF TRANSPORTATION GEOTECHNICAL SPECIFICATIONS FOR ROADWAY DESIGN. June 29, 2011

STATE OF OKLAHOMA DEPARTMENT OF TRANSPORTATION GEOTECHNICAL SPECIFICATIONS FOR ROADWAY DESIGN. June 29, 2011 STATE OF OKLAHOMA DEPARTMENT OF TRANSPORTATION GEOTECHNICAL SPECIFICATIONS FOR ROADWAY DESIGN June 29, 2011 APPENDIX 5. STANDARD FORMS FOR REPORTING GEOTECHNICAL INFORMATION In order to insure uniformity

More information

Foundation Indicator Test Data

Foundation Indicator Test Data (Proprietary) Limited. Registration No: 1998/1971/7 BRANCHES: CENTURION JOHANNESBURG PIETERMARITZBURG PINETOWN PORT ELIZABETH RUSTENBURG VRYHEID A SANAS accredited testing laboratory No T62 36/38 Fourth

More information

Geoscience Testing laboratory (Al Ain)

Geoscience Testing laboratory (Al Ain) Soil 1 In-situ Density by Sand Replacement Method Using Large Pouring Cylinder & Small Pouring Cylinder In-place Density Test by Sand Cone Method BS 1 Part ASTM D 1556 Dry Density Moisture Content Relationship

More information

Build-A-Box Modular Trench Shielding System

Build-A-Box Modular Trench Shielding System AMERICA S TRENCH BOX BUILDER Build-A-Box Modular Trench Shielding System EFFICIENCY PRODUCTION Build-A-Box Tabulated Data Tabulated Data Effective January 4, 2010 Revised: January 4, 2018 - with CHANGE

More information

Build-A-Box. Modular Trench Shielding System. Tabulated Data Effective January 4, Revised: April 21, with CHANGE THREE

Build-A-Box. Modular Trench Shielding System. Tabulated Data Effective January 4, Revised: April 21, with CHANGE THREE Build-A-Box AMERICA S TRENCH BOX BUILDER Modular Trench Shielding System EFFICIENCY PRODUCTION, INC. Build-A-Box Tabulated Data Tabulated Data Effective January 4, 2010 Revised: April 21, 2015 - with CHANGE

More information

MINNESOTA DEPARTMENT OF TRANSPORTATION - GEOTECHNICAL SECTION LABORATORY LOG & TEST RESULTS - SUBSURFACE EXPLORATION UNIQUE NUMBER 62885

MINNESOTA DEPARTMENT OF TRANSPORTATION - GEOTECHNICAL SECTION LABORATORY LOG & TEST RESULTS - SUBSURFACE EXPLORATION UNIQUE NUMBER 62885 UNIQUE NUMBER 62885 Bridge No. or Job Desc. 79-08 712 Location Sibley Co. Coordinate: X=383182 Y=8844 Hammer Latitude (North)=44 37'56.85" AETH, 35+16.72, 26.4'RT Trunk Highway/Location (ft.) Longitude

More information

Hydraulic Report. County Road 595 Bridge over Second River. Prepared By AECOM Brian A. Hintsala, P.E

Hydraulic Report. County Road 595 Bridge over Second River. Prepared By AECOM Brian A. Hintsala, P.E Prepared for: Prepared by: Marquette County Road Commission AECOM Ishpeming, MI Marquette, MI 60240279 December 9, 2011 Hydraulic Report County Road 595 Bridge over Second River Prepared By AECOM Brian

More information

shall not exceed 8 not exceed 10.

shall not exceed 8 not exceed 10. Table 3602/1 CRUSHED STONE BASE AND SUBBASE: MATERIAL REQUIREMENTS Material TYPE OF MATERIAL Characteristic G1 G2 G3 Parent Sound rock from an approved Sound rock, boulders Sound rock, boulders or Material

More information

CONE PENETRATION TEST DATA

CONE PENETRATION TEST DATA CONE PENETRATION TEST DATA Proposed Logan Wastewater Plant Addition Logan, Utah July 30-31, 2014 Prepared for: IGES, Inc. Salt Lake City, Utah Prepared by: ConeTec, Inc. Salt Lake City, Utah August 4,

More information

CONTINUOUS FLIGHT AUGERS AND BITS

CONTINUOUS FLIGHT AUGERS AND BITS Mobile Standard Construction and HEX-COR augers have been tested in the field and independently tested in the laboratory and are proven to be equal to or stronger than any other auger in the industry.

More information

EXISTING PAVEMENT EVALUATION Howell Ferry Road Duluth, Gwinnett County, Georgia. WILLMER ENGINEERING INC. Willmer Project No

EXISTING PAVEMENT EVALUATION Howell Ferry Road Duluth, Gwinnett County, Georgia. WILLMER ENGINEERING INC. Willmer Project No EXISTING PAVEMENT EVALUATION WILLMER ENGINEERING INC. Prepared For Clark Patterson Lee Suwanee, Georgia Prepared By WILLMER ENGINEERING INC. 3772 Pleasantdale Road Suite 165 Atlanta, Georgia 30340-4270

More information

Table of Contents. Description

Table of Contents. Description Table of Contents Description Page A. Introduction... 1 A.1. Project Description... 1 A.2. Purpose... 1 A.3. Background Information and Reference Documents... 1 A.4. Site Conditions... 1 A.. Scope of Services...

More information

Opportunities and Challenges for the. Friday September 24,

Opportunities and Challenges for the. Friday September 24, LRFD Facts and Misconceptions: Opportunities and Challenges for the Micropile il Community Friday September 24, 2010 By Jerry A. DiMaggio, PE, M.ASCE Email: jdimaggio2@verizon.net Email: jdimaggio@nas.edu

More information

DYNAMIC PILE TESTING 10/26/ General.

DYNAMIC PILE TESTING 10/26/ General. te: The MoDOT LRFD Bridge Design Manual indicates that the frequency of dynamic pile testing should be 1 to 10% of the number of piles. Additionally, the frequency of initial driving tests and restrike

More information

5. Other Relevant Data

5. Other Relevant Data 5. Other Relevant Data 5 - TOPOGRAPHICAL SURVEY 5-2 GEOTECHNICAL INVESTIGATION 5-3 TRAFFIC VOLUME SURVEY 5-4 STRUCTURAL SOUNDNESS OF EXISTING BRIDGES 5-5 BRIDGE LOCATION STUDY Appendix 5- Topographical

More information

PD Thrust Restraint Design Equations and Tables

PD Thrust Restraint Design Equations and Tables Thrust Restraint Design Equations and Tables PD-6 5-95 These equations and tables are an effort to provide the piping system designer with conservative techniques and parameters for the design of underground

More information

Laboratory Certification For. Shakib Dastaggir Construction & Design Company (S-CAD) Laboratory

Laboratory Certification For. Shakib Dastaggir Construction & Design Company (S-CAD) Laboratory Laboratory Certification For Shakib Dastaggir Construction & Design Company (S-CAD) Laboratory Lab ID: LCP-006 Issue date: Sept 19, 2016 Expiry date: March 18, 2017 This letter confirms the completion

More information

DEPARTMENT OF TRANSPORTATION DIVISION: MATERIALS REPORT COVER SHEET

DEPARTMENT OF TRANSPORTATION DIVISION: MATERIALS REPORT COVER SHEET LD-4 7/1/9 DEPARTMENT OF TRANSPORTATION DIVISION: MATERIALS REPORT COVER SHEET Geotechnical Engineering Report March 31, 216 AECOM Technical Services, Inc. Virginia Beach, Virginia AECOM Germantown, Maryland

More information

Terminology, Shaft Comparison & General Discussion

Terminology, Shaft Comparison & General Discussion Helical Foundation Systems: Topics We Will Cover Considerations for the Design and Installation of Helical Pile Foundations Presented by: Kyle Olson, PE Senior Structural Engineer Foundation Supportworks,

More information

All Regional Engineers. Omer M. Osman, P.E. Special Provision for Hot-Mix Asphalt Mixture Design Composition and Volumetric Requirements July 25, 2014

All Regional Engineers. Omer M. Osman, P.E. Special Provision for Hot-Mix Asphalt Mixture Design Composition and Volumetric Requirements July 25, 2014 All Regional Engineers Omer M. Osman, P.E. Special Provision for Hot-Mix Asphalt Mixture Design Composition and Volumetric Requirements July 25, 2014 This special provision was developed by the Bureau

More information

H o l l o w S t e m A u g e r E q u i p m e n t

H o l l o w S t e m A u g e r E q u i p m e n t H o l l o w S t e m A u g e r E q u i p m e n t Pitcher Drilling s hollow stem auger rigs are used to collect soil samples and to construct/destruct monitoring or recovery wells. TRUCK AND TRACK MOUNTED

More information

Anchor Tools. Catalog 4A December Phone: Web: hubbellpowersystems.com December 2014.

Anchor Tools. Catalog 4A December Phone: Web: hubbellpowersystems.com December 2014. Anchor Tools Catalog 4A Page 4A-1 Page 4A-3 4A-4 4A-5 4A-6 4A-7 4A-8 4A-9 4A-10 4A-11 4A-12 4A-13 4A-14 4A-15 TABLE OF CONTENTS Subject How to match Chance PISA Anchors with Installing Wrenches PISA Drive

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA)

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA) MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA) CFS:TEH 1 of 10 APPR:KPK:JFS:07-07-16 FHWA:APPR:07-15-16 a. Description. This

More information

JURONG ROCK CAVERNS. Workshop on the Optimisation of Shaft Design 4 June 2013

JURONG ROCK CAVERNS. Workshop on the Optimisation of Shaft Design 4 June 2013 JURONG ROCK CAVERNS Development of Underground Rock Caverns for Hydrocarbon Storage on Jurong sland Workshop on the Optimisation of Shaft Design 4 June 2013 The Flow Journey of Jurong Rock Caverns Access

More information

Class 1 Crushed rock ballast for use primarily on main line track. Class 2 Crushed rock ballast for use only on other than main line track.

Class 1 Crushed rock ballast for use primarily on main line track. Class 2 Crushed rock ballast for use only on other than main line track. PAGE 1 OF 8 PART 1 - GENERAL REQUIREMENTS 1.1 DESCRIPTION OF SPECIFICATION This document outlines the material, stockpiling, and handling specifications of ballast. It covers the supply of ballast from

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK The Old School Stillhouse Lane Bedminster BS3 4EB Contact: Dr Dimitris Xirouchakis Tel: +44 (0)117-9471000 Fax: +44 (0)117-9471004 E-Mail:

More information

DIVISION III MATERIALS AGGREGATES SECTION 901 COARSE AGGREGATE

DIVISION III MATERIALS AGGREGATES SECTION 901 COARSE AGGREGATE DIVISION III MATERIALS AGGREGATES SECTION 901 COARSE AGGREGATE 901-1 General. 901-1.1 Composition: Coarse aggregate shall consist of naturally occurring materials such as gravel, or resulting from the

More information

ATTACHMENT D (As referenced in Attachment B ) (Hydrology and Hydraulics Study)

ATTACHMENT D (As referenced in Attachment B ) (Hydrology and Hydraulics Study) ATTACHMENT D (As referenced in Attachment B ) (Hydrology and Hydraulics Study) Southern California Edison So Cal Gas Sub-transmission Project Hydrology and Hydraulics Study January 2014 2 Hydrology & Hydraulics

More information

Evaluation of Pile Setup using Dynamic Restrike Analysis in Alabama Soils

Evaluation of Pile Setup using Dynamic Restrike Analysis in Alabama Soils 45 th STGEC - Mobile, AL Oct. 29, 2014 CE Pile 360 Setup Spring AL 13 Evaluation of Pile Setup using Dynamic Restrike Analysis in Alabama Soils Eric Steward, Ph.D. Assistant Professor University of South

More information

BACKCALCULATION OF LAYER MODULI OF GRANULAR LAYERS FOR BOTH RIGID AND FLEXIBLE PAVEMENTS. Ashvini Kumar Thottempudi

BACKCALCULATION OF LAYER MODULI OF GRANULAR LAYERS FOR BOTH RIGID AND FLEXIBLE PAVEMENTS. Ashvini Kumar Thottempudi BACKCALCULATION OF LAYER MODULI OF GRANULAR LAYERS FOR BOTH RIGID AND FLEXIBLE PAVEMENTS By Ashvini Kumar Thottempudi A THESIS Submitted to Michigan State University in partial fulfillment of the requirements

More information

Motorcycle ATV Braking Data Analysis. Progress Report

Motorcycle ATV Braking Data Analysis. Progress Report Motorcycle ATV Braking Data Analysis Progress Report Mark D. Osborne And Russ G. Alger Keweenaw Research Center Houghton, MI 49931 February 14 TABLE OF CONTENTS Page 1. INTRODUCTION... 1 2. MOTORCYCLE

More information

CONTINUOUS FLIGHT AUGERS AND BITS

CONTINUOUS FLIGHT AUGERS AND BITS CONTINUOUS FLIGHT AUGERS AND BITS Hex-Tube Augers Available in Hole Sizes 2½ (6 mm) through 12 (05 mm) Hex Sized 1 / 16, 1 1 / 8, 1 5 / 8 and 2 (20.6 mm, 29 mm, 1 mm and 50.8 mm) Field replacement shank

More information

APPENDIX A Basis of Design and Design Criteria Memorandum

APPENDIX A Basis of Design and Design Criteria Memorandum APPENDIX A Basis of Design and Design Criteria Memorandum Job No: Y01-500 Files are stored in: Engineering / Client / Yolo/Y01500 Buckeye and Rumsey/Rumsey CR 41 over Cache Creek, CAD files stored in:

More information

PREDICTION OF BALLAST RETURN FROM HIGH OUTPUT BALLAST CLEANERS (HOBC)

PREDICTION OF BALLAST RETURN FROM HIGH OUTPUT BALLAST CLEANERS (HOBC) PREDICTION OF BALLAST RETURN FROM HIGH OUTPUT BALLAST CLEANERS (HOBC) Dr W.L. Lim, Dr M. Brough & S. Middleton Scott Wilson Pavement Engineering 10 Faraday Building Nottingham Science & Technology Park

More information

Project Title: Using Truck GPS Data for Freight Performance Analysis in the Twin Cities Metro Area Prepared by: Chen-Fu Liao (PI) Task Due: 9/30/2013

Project Title: Using Truck GPS Data for Freight Performance Analysis in the Twin Cities Metro Area Prepared by: Chen-Fu Liao (PI) Task Due: 9/30/2013 MnDOT Contract No. 998 Work Order No.47 213 Project Title: Using Truck GPS Data for Freight Performance Analysis in the Twin Cities Metro Area Prepared by: Chen-Fu Liao (PI) Task Due: 9/3/213 TASK #4:

More information

Overburden drilling catalogue

Overburden drilling catalogue Atlas Copco Ground Engineering Products Overburden catalogue Symmetrix overburden systems Overburden Drilling Catalogue Atlas Copco Overburden Drilling System... 3 The Symmetrix System... 4 Drilling overburden...

More information

TYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System

TYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System 1.01 Typical Installation Scope TYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System Section 1- General Furnish labor, equipment, tools and material to install the PPB-300 Steel Piers as

More information

Approximately 11,200 mm c/c (field measurement) Two glulam slab girders mm x 1210 mm; 3100 mm clear distance between girders.

Approximately 11,200 mm c/c (field measurement) Two glulam slab girders mm x 1210 mm; 3100 mm clear distance between girders. BRIDGE INSPECTION BRIDGE NO./NAME SI - 3041: Mt. Brenton FSR (2.00 KM) Inspection Date: October 31 st 2012 Inspected By: D. Chen, D. Harrison Year Built: 1995 Number of Spans: 1 Span Lengths: Superstructure

More information

Long Life Asphalt Performance Testing January 17, 2018

Long Life Asphalt Performance Testing January 17, 2018 PennDOT District 11 Long Life Asphalt Performance Testing January 17, 2018 Jim Foringer, P.E. Assistant District Executive Construction Division Neal Fannin, P.E. Pavement Materials Engineer BOPD Construction

More information

TACOMA PUMP STATION 4103 FORCE MAIN HDD PROJECT: A SHORT BORE WITH TALL CHALLENGES

TACOMA PUMP STATION 4103 FORCE MAIN HDD PROJECT: A SHORT BORE WITH TALL CHALLENGES North American Society for Trenchless Technology (NASTT) No-Dig Show 2011 Washington, D.C. March 27-31, 2011 Paper D-2-04 TACOMA PUMP STATION 4103 FORCE MAIN HDD PROJECT: A SHORT BORE WITH TALL CHALLENGES

More information

1 st Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations. Prepared for:

1 st Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations. Prepared for: 1 st Quarter 2018 Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations Prepared for: Prepared by: Mr. Bryce C. Bird Director Division of Air Quality 195 North

More information

AxeBlade. Ridged diamond element bit

AxeBlade. Ridged diamond element bit AxeBlade Ridged diamond element bit Instantaneous ROP Improvement. Better Steerability. The AxeBlade* ridged diamond element bit positions Axe* elements along the bit face to achieve increased ROP and

More information

Dando Drilling International

Dando Drilling International Dando Drilling International Dando Terrier and Tooling The Dando Terrier drilling rig has been designed specifically for sampling and testing for geotechnical and environmental analysis. The rig is crawler

More information

RE: S.P (T.H. 210) in Crow Wing County Located on T.H. 210 from Brainerd (R.P ) to Ironton (R.P )

RE: S.P (T.H. 210) in Crow Wing County Located on T.H. 210 from Brainerd (R.P ) to Ironton (R.P ) District 3 Administration 7964 Industrial Park Road Baxter, MN 56425 Memo To: Dan Anderson Transportation District Engineer From: Scott Zeidler Senior Engineering Specialist Date: December 11, 2017 RE:

More information

Stabilization of Clay Soil Using A-3 Soil

Stabilization of Clay Soil Using A-3 Soil Stabilization of Clay Soil Using A-3 Soil Mohammed Mustapha Alhaji, Salawu Sadiku Abstract A clay soil classified as A-7-6 and CH soil according to AASHTO and unified soil classification system respectively,

More information

MINE SAFETY AND HEALTH ADMINISTRATION STAKEHOLDER MEETING BECKLEY, WV JUNE 8, 2017

MINE SAFETY AND HEALTH ADMINISTRATION STAKEHOLDER MEETING BECKLEY, WV JUNE 8, 2017 MINE SAFETY AND HEALTH ADMINISTRATION STAKEHOLDER MEETING BECKLEY, WV JUNE 8, 2017 AGENDA Introduction Tim Watkins Deputy Administrator for CMS&H Remarks Patricia Silvey Deputy Assistant Secretary for

More information

P.12 P.23 P.24 P.26 DRILLING RIGS AND ACCESSORIES

P.12 P.23 P.24 P.26 DRILLING RIGS AND ACCESSORIES DRILLING RIGS AND ACCESSORIES P.12 HEAVY DYNAMIC PENETROMETER AND DRILLING RIGS APAFOR APAFOR 50 APAFOR 100 APAFOR 200 APAFOR 220 APAFOR 330 AND 340 APAFOR 430 APAFOR 450 RS APAFOR 450 APAFOR 550 AND 560

More information

TRB Workshop Implementation of the 2002 Mechanistic Pavement Design Guide in Arizona

TRB Workshop Implementation of the 2002 Mechanistic Pavement Design Guide in Arizona TRB Workshop Implementation of the 2002 Mechanistic Pavement Design Guide in Arizona Matt Witczak, ASU Development of Performance Related Specifications for Asphalt Pavements in the State of Arizona 11

More information

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket TEST REPORT Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket Report No: Report Date: 10/31/12 130 Derry Court York, PA 17406-8405 phone:

More information

Industry/PennDOT Initiative On Performance Testing. AN UPDATE January 22, 2019

Industry/PennDOT Initiative On Performance Testing. AN UPDATE January 22, 2019 Industry/PennDOT Initiative On Performance Testing AN UPDATE January 22, 2019 Outline Testing Modes A Review of Semi-Circular Bend (SCB) Test PA Industry Initiative on SCB Results & Observations Next Steps

More information

Shoulder Ballast Cleaning Effectiveness

Shoulder Ballast Cleaning Effectiveness Shoulder Ballast Cleaning Effectiveness AREMA 2015 Annual Conference 4 October 7 October 2015 Minneapolis, MN Scott Diercks Loram Maintenance of Way, Inc. 3900 Arrowhead Drive Hamel, MN 55340 763-478-2622

More information

D-25 Drill Rig. 700 Hicks Drive, Elburn, IL Phone:

D-25 Drill Rig. 700 Hicks Drive, Elburn, IL Phone: Power Source: Gasoline or Diesel Engine Maximum Gross Spindle Torque: 2320 ft. lbs. (3145 Nm) to 3066 ft. lbs. (4156 Nm) Spindle Bore: 2-3/8 (60mm) Spindle Travel: 66 (1,676mm) Spindle & Retract Force

More information

Transportation Engineering II UNIT - I

Transportation Engineering II UNIT - I Transportation Engineering II UNIT - I I. Components of a Permanent Way: A. Rails: Rails are the I-section members of a track laid in two parallel lines to provide a level surface for the movement of trains.

More information

August 7, Mr. Stephen Kokenes Phone: Nomaco Inc. Fax: NMC Drive Zebulon, NC 27597

August 7, Mr. Stephen Kokenes Phone: Nomaco Inc. Fax: NMC Drive   Zebulon, NC 27597 August 7, 2015 Mr. Stephen Kokenes Phone: 919-380-6636 Nomaco Inc. Fax: 919-269-7936 501 NMC Drive Email: skokenes@nomaco.com Zebulon, NC 27597 Subject: Report of ASTM D545 Testing Project Name: Samples

More information

MESA Cornerstone Segmental Retaining Wall Unit and Tensar Geogrid Connection Strength Testing

MESA Cornerstone Segmental Retaining Wall Unit and Tensar Geogrid Connection Strength Testing MESA Cornerstone Segmental Retaining Wall Unit and Tensar Geogrid Connection Strength Testing Prepared for Tensar Earth Technologies, Inc. 5883 Glenridge Drive, Suite 2 Atlanta, GA 3328 Prepared by National

More information

Time-Dependent Behavior of Structural Bolt Assemblies with TurnaSure Direct Tension Indicators and Assemblies with Only Washers

Time-Dependent Behavior of Structural Bolt Assemblies with TurnaSure Direct Tension Indicators and Assemblies with Only Washers Time-Dependent Behavior of Structural Bolt Assemblies with TurnaSure Direct Tension Indicators and Assemblies with Only Washers A Report Prepared for TurnaSure, LLC Douglas B. Cleary, Ph.D., P.E. William

More information

OF SPECIFICATION SHEET, ONLY NO. (Type, size, model number, etc.) FILE NO. CODE d. e. f. g.

OF SPECIFICATION SHEET, ONLY NO. (Type, size, model number, etc.) FILE NO. CODE d. e. f. g. TRANSMITTAL OF SHOP DRAWINGS, EQUIPMENT DATA, MATERIAL SAMPLES, OR MANUFACTURER'S CERTIFICATES OF COMPLIANCE FOR APPROVAL (READ INSTRUCTION ON THE REVERSE SIDE PRIOR TO INITIATING THIS FORM) 1. REQUEST

More information

Appendix D. Noise Calculations

Appendix D. Noise Calculations Appendix D Noise Calculations Summary of Boating Activity Changes Associated with each Alternative Peak Day Boating Trips Structure Existing With Alt increase with alt 2 increase with alt 3 increase with

More information

Implementation and Thickness Optimization of Perpetual Pavements in Ohio

Implementation and Thickness Optimization of Perpetual Pavements in Ohio Implementation and Thickness Optimization of Perpetual Pavements in Ohio OTEC 2015 Issam Khoury, PhD, PE Russ College of Engineering and Technology Ohio University, Athens, Ohio Outline Background prior

More information

Use of New High Performance Thin Overlays (HPTO)

Use of New High Performance Thin Overlays (HPTO) Northeast Asphalt User/Producer Group Wilmington/Christiana Delaware October 11-12, 2006 Use of New High Performance Thin Overlays (HPTO) Thomas Bennert Rutgers University NJ s s Thin-Lift Materials New

More information

Hydraulic power is the key to the utility of many excavators.

Hydraulic power is the key to the utility of many excavators. CHAPTER Construction Planning, Equipment, and Methods EXCAVATORS Sixth Edition A. J. Clark School of Engineering Department of Civil and Environmental Engineering 8 By Dr. Ibrahim Assakkaf ENCE 420 Construction

More information

PERMANENT RESIDENTIAL UNDERGROUND SERVICE

PERMANENT RESIDENTIAL UNDERGROUND SERVICE CITY OF RICHLAND ENERGY SERVICES DEPARTMENT 505 Swift Boulevard, MS-21 Richland, WA 99352 Telephone (509) 942-7403 Fax (509) 942-7405 PERMANENT RESIDENTIAL UNDERGROUND SERVICE A. INTRODUCTION This guide

More information

EXCEPTION TO STANDARDS REPORT

EXCEPTION TO STANDARDS REPORT EXCEPTION TO STANDARDS REPORT PROJECT DESCRIPTION AND NEED The project is located in Section 6, Township 23 North, Range 9 East and Section 31 Township 24 North, Range 9 East, in the Town of Stockton,

More information

1st Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations

1st Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations 1st Quarter 2014 Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations Steven A. Root Digitally signed by Steven A. Root DN: cn=steven A. Root, o=weatherbank,

More information

DMS-9202 Asphaltic Concrete Patching Material (Stockpile Storage or Bagged)

DMS-9202 Asphaltic Concrete Patching Material (Stockpile Storage or Bagged) Asphaltic Concrete Patching Material (Stockpile Storage or Bagged) Effective Date: May 2017 1. DESCRIPTION This Specification governs for crushed stone asphaltic concrete intended primarily as a cool-

More information

6.3 SUBSTRATE COMPOSITION AND QUALITY

6.3 SUBSTRATE COMPOSITION AND QUALITY 6.3 SUBSTRATE COMPOSITION AND QUALITY 6.3.1 METHODS The Wolman pebble count procedure (Wolman, 1954) is used to measure the diameter of the intermediate axis of 100 randomly selected stones along transects

More information

SKID RESISTANCE EVALUATION PROGRAM

SKID RESISTANCE EVALUATION PROGRAM SKID RESISTANCE EVALUATION PROGRAM P a u l O w e n s Director ISH C Research and Training Center West Lafayette, Indiana H IS T O R Y Indiana started skidding roads in 1968 with a towed-trailer type skid

More information

ATTACHMENT E METHOD COMPARABILITY STUDY SUMMARY USEPA 1613B AND METHOD 1613-TRP/RT

ATTACHMENT E METHOD COMPARABILITY STUDY SUMMARY USEPA 1613B AND METHOD 1613-TRP/RT TTHMENT E METHOD OMPRBILITY STUDY SUMMRY USEP 1613B ND METHOD 1613-TRP/RT GEOMORPH SITE HRTERIZTION UPPER TITTBWSSEE RIVER NN RBOR TEHNIL SERVIES, IN. nn rbor, Michigan 48103 Low Level Method omparability

More information

A demonstration project for recharge in the Upper San Pedro subwatershed COMMUNITY DEVELOPMENT DEPARTMENT

A demonstration project for recharge in the Upper San Pedro subwatershed COMMUNITY DEVELOPMENT DEPARTMENT A demonstration project for recharge in the Upper San Pedro subwatershed COMMUNITY DEVELOPMENT DEPARTMENT Highway and Floodplain Cochise County Grant Grant amount- up to $1,693,265 over 3 years Components:

More information

PVC Pressure Piping Systems for Water Transmission

PVC Pressure Piping Systems for Water Transmission PVC Pressure Piping Systems for Water Transmission MUNICIPAL SYSTEMS PVC PRESSURE PIPING SYSTEM MANUFACTURED TO AWWA & CSA STANDARDS IPEX Centurion 14" 60" (350mm 1,500mm), AWWA C905 and CSA Standards

More information

Depth of Bury Tables 9B-5. A. General. B. Rigid Pipe Assumptions. Design Manual Chapter 9 - Utilities 9B - Trench Design

Depth of Bury Tables 9B-5. A. General. B. Rigid Pipe Assumptions. Design Manual Chapter 9 - Utilities 9B - Trench Design Design Manual Chapter 9 - Utilities 9B - Trench Design 9B-5 Depth of Bury Tables A. General The depth of bury tables on the following pages are based upon the design methodology from the various pipe material

More information

NCAT/MnROAD Cracking Group Update. March 29, 2018

NCAT/MnROAD Cracking Group Update. March 29, 2018 NCAT/MnROAD Cracking Group Update March 29, 2018 Outline Project background Laboratory testing Pavement response Performance observations 2 Cracking Group Experiment Primary objective Correlate lab cracking

More information

AEM-Based Hydrogeological Frameworks in the Central Valley of California

AEM-Based Hydrogeological Frameworks in the Central Valley of California AEM-Based Hydrogeological Frameworks in the Central Valley of California Ted Asch, PhD., P.Gp., P.G. Jared Abraham, MSc., P.Gp., P.G. James Cannia, P.G. Aqua Geo Frameworks, LLC March 21, 2017 21 March

More information

Trip Generation and Parking Study New Californian Apartments, Berkeley

Trip Generation and Parking Study New Californian Apartments, Berkeley Trip Generation and Parking Study New Californian Apartments, Berkeley Institute of Transportation Engineers University of California, Berkeley Student Chapter Spring 2012 Background The ITE Student Chapter

More information

Plastic Hinging Considerations for Single-Column Piers Supporting Highly Curved Ramp Bridges

Plastic Hinging Considerations for Single-Column Piers Supporting Highly Curved Ramp Bridges Plastic Hinging Considerations for Single-Column Piers Supporting Highly Curved Ramp Bridges Western Bridge Engineers Seminar Reno, NV Greg Griffin, P.E., S.E. - Senior Bridge Engineer e Griffin, P.E.,

More information

Weather Louvre Test. Report 57668/1. Carried out for Seng Yoon Seng Holdings SDN. BHD. By Andrew Freeth. 14 January 2014

Weather Louvre Test. Report 57668/1. Carried out for Seng Yoon Seng Holdings SDN. BHD. By Andrew Freeth. 14 January 2014 Weather Louvre Test Report 57668/1 Carried out for Seng Yoon Seng Holdings SDN. BHD By Andrew Freeth 14 January 2014 Weather Louvre Test Carried out for: Seng Yoon Seng Holdings SDN. BHD No. 46, Jalan

More information

SKID RESISTANCE OF ROADS CONTAMINATED WITH GRAVEL

SKID RESISTANCE OF ROADS CONTAMINATED WITH GRAVEL SKID RESISTANCE OF ROADS CONTAMINATED WITH GRAVEL L D V ROODT University of Stellenbosch, Department of Civil Engineering, Stellenbosch, 7600 Tel: 021 808 4079; Email: ldvroodt@sun.ac.za ABSTRACT Skid

More information

Kansas Department of Transportation DISTRICT 2. Project(s): Min: Max:

Kansas Department of Transportation DISTRICT 2. Project(s): Min: Max: Page 1 of 23 518122 SECTION: 01 COMMON ITEMS 1 020100 CONTRACTOR CONSTRUCTION STAKING 2 025602 FIELD OFFICE AND LABORATORY (TYPE C) 3 025323 MOBILIZATION 4 070626 MOBILIZATION (DBE) 5 020001 MAINTENANCE

More information

W10 SPECIFICATIONS Teeth, Adapters, Accessories

W10 SPECIFICATIONS Teeth, Adapters, Accessories W10 SPECIFICATIONS Teeth, Adapters, Accessories BE GPE AE SL-lock ML-lock T-tool Typical machine weight - Excavator 25-50 MT 232 kn Type Part. no Weight Lip A B C D E F G kg thickness mm mm mm mm mm mm

More information

Shale Oil & Gas. Overview of Shale HC Potential in Onshore East Malaysia. May PETROLIAM NASIONAL BERHAD (PETRONAS)

Shale Oil & Gas. Overview of Shale HC Potential in Onshore East Malaysia. May PETROLIAM NASIONAL BERHAD (PETRONAS) Shale Oil & Gas Overview of Shale HC Potential in Onshore East Malaysia May 2016 2015 PETROLIAM NASIONAL BERHAD (PETRONAS) All rights reserved. No part of this document may be reproduced, stored in a retrieval

More information

for U Sheet Piles mm wide

for U Sheet Piles mm wide for U Sheet Piles 00-00mm wide Modular model applicable to U Sheet Piles (00-00mm wide) Silent Piler F0 Flexible and Functional Formula The F0 features a new modular design developed by optimising all

More information

SITE PLANS ASSISTED LIVING REDEVELOPMENT

SITE PLANS ASSISTED LIVING REDEVELOPMENT SITE PLANS ASSISTED LIVING REDEVELOPMENT PROJECT SUMMARY TOTAL LOT AREA - 39.0 ACRES EXISTING BUILDING FOOTPRINT 48,060 S.F. PROPOSED 25,869 S.F. TOTAL BUILDING FOOTPRINT 73,929 S.F. ZONING COMPLIANCE

More information

Minnesota DOT -- RDM Experience. Dr. Kyle Hoegh, MnDOT Dr. Shongtao Dai, MnDOT Dr. Lev Khazanovich, U. of Pittsburgh

Minnesota DOT -- RDM Experience. Dr. Kyle Hoegh, MnDOT Dr. Shongtao Dai, MnDOT Dr. Lev Khazanovich, U. of Pittsburgh Minnesota DOT -- RDM Experience Dr. Kyle Hoegh, MnDOT Dr. Shongtao Dai, MnDOT Dr. Lev Khazanovich, U. of Pittsburgh Acknowledgements FHWA/AASHTO for providing RDM MnDOT district materials and constructions

More information

Settlement Analyses of Grade Supported Tanks Constructed with the Use of Prefabricated Wick Drains and an Earth Preload

Settlement Analyses of Grade Supported Tanks Constructed with the Use of Prefabricated Wick Drains and an Earth Preload University of New Orleans ScholarWorks@UNO University of New Orleans Theses and Dissertations Dissertations and Theses 5-20-2011 Settlement Analyses of Grade Supported Tanks Constructed with the Use of

More information

Contract No: OASRTRS-14-H-MST (Missouri University of Science and Technology)

Contract No: OASRTRS-14-H-MST (Missouri University of Science and Technology) Smart Rock Technology for Real-time Monitoring of Bridge Scour and Riprap Effectiveness Design Guidelines and Visualization Tools (Progress Report No. 7) Contract No: OASRTRS-14-H-MST (Missouri University

More information

4th Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations

4th Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations 4th Quarter 2016 Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations Steven Root Digitally signed by Steven Root DN: cn=steven Root, o=weatherbank, Inc., ou,

More information

Shoulder Ballast Cleaning Effectiveness

Shoulder Ballast Cleaning Effectiveness Shoulder Ballast Cleaning Effectiveness Word count: 3539 ABSTRACT AREMA 2015 Annual Conference 4 October 7 October 2015 Minneapolis, MN Scott Diercks Loram Maintenance of Way, Inc. 3900 Arrowhead Drive

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ccredited to Bootham Lane Industrial Estate Bootham Lane Dunscroft Doncaster

More information

JRC EFFECTS OF BALLAST DEGRADATION ON PERMANENT DEFORMATION BEHAVIOR FROM LARGE-SCALE TRIAXIAL TESTS

JRC EFFECTS OF BALLAST DEGRADATION ON PERMANENT DEFORMATION BEHAVIOR FROM LARGE-SCALE TRIAXIAL TESTS Proceedings of the 214 Joint Rail Conference JRC214 April 2-4, 214, Colorado Springs, CO, USA JRC214-386 EFFECTS OF BALLAST DEGRADATION ON PERMANENT DEFORMATION BEHAVIOR FROM LARGE-SCALE TRIAXIAL TESTS

More information

May 19, Mr. Tommy McKoin, Manager Coca-Cola of South Arkansas 3325 Highway 7 South Camden, AR Dear Mr. McKoin:

May 19, Mr. Tommy McKoin, Manager Coca-Cola of South Arkansas 3325 Highway 7 South Camden, AR Dear Mr. McKoin: May 19, 2008 Mr. Tommy McKoin, Manager Coca-Cola of South Arkansas 3325 Highway 7 South Camden, AR 71701 RE: AFIN: 52-00050 Permit No.: 4536-WG-CW Dear Mr. McKoin: On April 23, 2008, I performed a routine

More information

IROn PIPe. McWane DUcTILe

IROn PIPe. McWane DUcTILe McWane DUcTILe IROn PIPe nsf 61 ISO 9001 DIPRa Boltless restrained joint systems Multiple design options available from 3 36 Fast and easy installation 350 pressure rating Independently tested www.mcwane.com

More information

Rehabilitating Crossing Surfaces Effect of Sub-Structure Design on Long-Term Performances of Highway-Railway At-Grade Crossings

Rehabilitating Crossing Surfaces Effect of Sub-Structure Design on Long-Term Performances of Highway-Railway At-Grade Crossings Rehabilitating Crossing Surfaces Effect of Sub-Structure Design on Long-Term Performances of Highway-Railway At-Grade Crossings by Jerry G. Rose, Ph.D.,P.E. Professor of Civil Engineering University of

More information

REPORT ON SCALA PENETROMETER IRREGULARITY

REPORT ON SCALA PENETROMETER IRREGULARITY REPORT ON SCALA PENETROMETER IRREGULARITY Associated Test Method(s) NZS4402: 1988 supplement Test 6.5.2 Author(s) SJ Anderson, Geotechnics Ltd Report Date May 2010 NZS4402: 1988 supplement Test 6.5.2 Page

More information

ABC Anchors & Autoguide Equipment product information

ABC Anchors & Autoguide Equipment product information ABC Anchors & Autoguide Equipment product information www.autoguide.co.uk www.abcanchors.co.uk ABC Anchors Stockley Road Heddington Wiltshire SN11 0PS ENGLAND +44 (0) 1380 850 885 ABC Anchors & Autoguide

More information

PENTAGON PROTECTION USA

PENTAGON PROTECTION USA PENTAGON PROTECTION USA Shock Tube Testing for Window Systems March 2009 San Antonio, Texas ABS Consulting Project Number 2127174 ABSG Consulting, Inc. 14607 San Pedro, Suite 215 San Antonio, TX 78232

More information

PERFORMANCE TEST REPORT. Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent

PERFORMANCE TEST REPORT. Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent Architectural Testing PERFORMANCE TEST REPORT Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent This report contains in its entirety: Cover Page: 1 page Report Body: 6 pages

More information

Trip Generation Study: Provo Assisted Living Facility Land Use Code: 254

Trip Generation Study: Provo Assisted Living Facility Land Use Code: 254 Trip Generation Study: Provo Assisted Living Facility Land Use Code: 254 Introduction The Brigham Young University Institute of Transportation Engineers (BYU ITE) student chapter completed a trip generation

More information