August 7, Mr. Stephen Kokenes Phone: Nomaco Inc. Fax: NMC Drive Zebulon, NC 27597

Size: px
Start display at page:

Download "August 7, Mr. Stephen Kokenes Phone: Nomaco Inc. Fax: NMC Drive Zebulon, NC 27597"

Transcription

1 August 7, 2015 Mr. Stephen Kokenes Phone: Nomaco Inc. Fax: NMC Drive Zebulon, NC Subject: Report of ASTM D545 Testing Project Name: Samples R & N TEC Project No.: TEC TEC Laboratory No.: Dear Mr. Kokenes, Testing Engineering and Consulting Services, Inc. (TEC Services) is an AASHTO R18 and Army Corp of Engineers accredited independent laboratory in compliance with ANS/ISO/IEC Standard 17025:2005. TEC Services is pleased to present this report on the testing of the two submitted polypropylene expansion joint filler materials which were received on July 21, The submitted materials were designated as &. This work was performed in accordance with our Service Agreement (TEC-PRO ). The test results presented only pertain to the samples tested. The purpose of the testing was to evaluate the performance of the submitted samples in accordance with the applicable sections of ASTM D Standard Test Methods for Preformed Expansion Joint Fillers for Concrete Construction (Nonextruding and Resilient Types). Test method for determination of asphalt content was not performed based on the composition of the material. Recovery & Compression Five 4 x 4 specimens were tested for recovery and compression in accordance with Section 7.2. Upon determining the initial thickness the specimens were loaded in compression at a rate of 0.05 in./min of crosshead displacement until reaching 50% of the original specimen thickness. The load was recorded and then released and the specimen allowed to recover for a period of 10 minutes before taking final measurements for thickness. Test results are reported in Table 1.

2 Project: & N ASTM D545 Five 4 x 4 specimens were tested for extrusion in accordance with Section The specimens were placed in a three sided steel as described in ASTM D545. A steel plate matching the dimensions of the specimen was loaded at a rate of 0.05 in./min until reaching 50% of the original thickness. The maximum movement of the free edge of the test specimen was then measured. Test results are reported in Table 2. Boiling in Hydrochloric Acid One 4 x 4 specimen from each sample type was immersed and boiled in 37% HCL for a duration of 1 hour. The specimens were then removed from solution and observed for any signs of deterioration. No signs of deterioration were observed in either or. A photo of the specimens after immersion is shown in Photo 1. Absorption & Density Three 4 x 4 specimens from each sample type were tested for absorption and density in accordance with Section 7.6 and 7.7. The specimens were weighed and measured prior to being immersed in distilled water at a depth of 1.00 for a period of 24 hrs. The specimens were removed from the water and blotted with a paper towel to a surface dried condition before taking final weights. For density the specimens were air dried and placed in a chamber at 65 ± 1 % RH and 68 ± 6 F until reaching a constant mass. The density was then determined based on the weight and dimensions of the specimens. Test results are reported in Table 3. Expansion in Boiling Water Five 4 x 4 specimens from each sample type were tested for expansion in boiling water. Measurements for initial thickness were taken prior immersion in boiling distilled water for a period of 1 hour. The specimens were removed from solution and allowed to cool for 15 minutes before taking final measurements for thickness. Test results are reported in Table 4. We appreciate the opportunity to provide our services to you on this project. Please do not hesitate to contact us at your convenience if you have any questions about this report or if we may be of further assistance. TESTING, ENGINEERING & CONSULTING SERVICES, INC. James G. McCants III Laboratory Manager, Chemist Shawn P. McCormick Laboratory Principal Attachments: Tables 1-4, Photo 1 Page 2 of 5

3 Project: & N ASTM D545 Table 1 Recovery & Compression Unit Peak Load Recovery Pressure (lbs) (in) (in) (psi) % % % % % Average % Unit Peak Load Recovery Pressure (lbs) (in) (in) (psi) % % % % % Average % Table 2 50% Compressio Measuremen Measuremen (in) n t t Average ID Area (in 2 ) 50% Compressio Measuremen Measuremen (in) n t t Average Page 3 of 5

4 Project: & N ASTM D545 Table 3 Absorption & Density ID (g) Absorption by Volume Density (pcf) ID Average (g) Absorption by Volume Density (pcf) Average Sample I.D. Table 4 Expansion in Boiling Water % Expansion Sample I.D. Average % Expansion Average Page 4 of 5

5 Project: & N ASTM D545 Photo 1 Specimens after Boiling in 37% HCL Page 5 of 5

Mr. Gabriel Ojeda Fritz-Pak Corporation Phone: (214) Eastover Circle Fax: (214)

Mr. Gabriel Ojeda Fritz-Pak Corporation Phone: (214) Eastover Circle Fax: (214) December 15, 2011 Mr. Gabriel Ojeda Fritz-Pak Corporation Phone: (214) 221-9494 4821 Eastover Circle Fax: (214) 341-3182 Mesquite, TX 75149 Email: gabrielojeda@fritzpak.com Subject: Final Report (Revised)

More information

C.R. Barger & Sons, Inc.

C.R. Barger & Sons, Inc. C.R. Barger & Sons, Inc. Shipping: 123 Pawnook Farm Road Lenoir City TN 37771 Mailing: P.O. Box 370 Kingston TN 37763 Five generations. One goal. Quality precast concrete. NPCA Certified Plant Phone: (865)

More information

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket TEST REPORT Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket Report No: Report Date: 10/31/12 130 Derry Court York, PA 17406-8405 phone:

More information

Crude Assay Report. Crude Oil sample marked. Barrow Crude Oil. On Behalf Of. Chevron Australia Pty Ltd. Laboratory Supervisor. Crude Assay Chemist

Crude Assay Report. Crude Oil sample marked. Barrow Crude Oil. On Behalf Of. Chevron Australia Pty Ltd. Laboratory Supervisor. Crude Assay Chemist Crude Assay Report on Crude Oil sample marked Barrow Crude Oil On Behalf Of Chevron Australia Pty Ltd. Reported by: Approved by: Michelle Fernandez Laboratory Supervisor Jhonas Fernandez Crude Assay Chemist

More information

STATE OF OKLAHOMA DEPARTMENT OF TRANSPORTATION GEOTECHNICAL SPECIFICATIONS FOR ROADWAY DESIGN. June 29, 2011

STATE OF OKLAHOMA DEPARTMENT OF TRANSPORTATION GEOTECHNICAL SPECIFICATIONS FOR ROADWAY DESIGN. June 29, 2011 STATE OF OKLAHOMA DEPARTMENT OF TRANSPORTATION GEOTECHNICAL SPECIFICATIONS FOR ROADWAY DESIGN June 29, 2011 APPENDIX 5. STANDARD FORMS FOR REPORTING GEOTECHNICAL INFORMATION In order to insure uniformity

More information

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( ) Test certificate Nr. 3666/4421-a -Fe/Wi- page 1 TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS INSTITUTE FOR REASEARCH OF CIVIL ENGINEERING MATERIALS, STONE- AND CONCRETE CONSTRUCTION AND FIRE INTEGRITY

More information

Geoscience Testing laboratory (Al Ain)

Geoscience Testing laboratory (Al Ain) Soil 1 In-situ Density by Sand Replacement Method Using Large Pouring Cylinder & Small Pouring Cylinder In-place Density Test by Sand Cone Method BS 1 Part ASTM D 1556 Dry Density Moisture Content Relationship

More information

CONTINUOUS IMMERSION AND DUST TEST REPORT

CONTINUOUS IMMERSION AND DUST TEST REPORT Report No. :HS1404020081A Version:A CONTINUOUS IMMERSION AND DUST TEST REPORT Company Address :Taiway Electronics Components Co. :4F., No. 4, 6, 8, Lane 359, Sec. 2, Zhongshan Rd., Zhonghe Dist., New Taipei

More information

FIRE TEST REPORT FH 5078

FIRE TEST REPORT FH 5078 1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE TEST REPORT FH 5078 CONE CALORIMETER TEST AND NZBC ACCEPTABLE SOLUTIONS

More information

MILITARY SPECIFICATION CORROSION PREVENTIVE COMPOUNDS, WATER DISPLACING, ULTRA-THIN FILM PAGE 1

MILITARY SPECIFICATION CORROSION PREVENTIVE COMPOUNDS, WATER DISPLACING, ULTRA-THIN FILM PAGE 1 NOT MEASUREMENT SENSITIVE 26 November 1997 SUPERSEDING AMENDMENT 2 31 July 1996 MILITARY SPECIFICATION CORROSION PREVENTIVE COMPOUNDS, WATER DISPLACING, ULTRA-THIN FILM This amendment forms a part of,

More information

THERMAL SHOCK TEST REPORT

THERMAL SHOCK TEST REPORT Report No. :DH1509300024A Version:A THERMAL SHOCK TEST REPORT Company :FLIP CHIP OPTO. INC. Address :No.185, Kewang Rd., Longtan Dist., Taoyuan City 325, Taiwan (R.O.C.) Model Name :Apollo 600-B Lot Number

More information

Section 4 DMS-9203, Asphaltic Concrete Patching Material (Containerized)

Section 4 DMS-9203, Asphaltic Concrete Patching Material (Containerized) Section 4 DMS-9203, Asphaltic Concrete Patching Overview Effective Date: August 2004 - December 2005. This Specification governs for rapid curing containerized asphaltic concrete mixture intended primarily

More information

FIRE TEST REPORT FH 5728

FIRE TEST REPORT FH 5728 1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE TEST REPORT FH 5728 CONE CALORIMETER TEST AND NZBC VERIFICATION METHOD

More information

FIRE TEST REPORT FH 5154

FIRE TEST REPORT FH 5154 1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE TEST REPORT FH 5154 CONE CALORIMETER TEST AND NCC SPECIFICATION C1.10

More information

DMS-9202 Asphaltic Concrete Patching Material (Stockpile Storage or Bagged)

DMS-9202 Asphaltic Concrete Patching Material (Stockpile Storage or Bagged) Asphaltic Concrete Patching Material (Stockpile Storage or Bagged) Effective Date: May 2017 1. DESCRIPTION This Specification governs for crushed stone asphaltic concrete intended primarily as a cool-

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CONTINENTAL AUTOMOTIVE SYSTEMS 570 Capital Drive Lake Zurich, IL 60047 Mr. Ken Klimek (Authorized Representative) Phone: 847-862-0131 Email: ken.klimek@continental-corporation.com

More information

Alberta Innovates - Technology Futures ~ Fuels & Lubricants

Alberta Innovates - Technology Futures ~ Fuels & Lubricants Report To: 5 Kings College Road Toronto, Ontario, M5S 3G8 Attention: Curtis Wan E-mail: curtis.wan@utoronto.ca Fax: Alberta Innovates - Technology Futures ~ Fuels & Lubricants 250 Karl Clark Road, Edmonton,

More information

Laboratory Certification For. Shakib Dastaggir Construction & Design Company (S-CAD) Laboratory

Laboratory Certification For. Shakib Dastaggir Construction & Design Company (S-CAD) Laboratory Laboratory Certification For Shakib Dastaggir Construction & Design Company (S-CAD) Laboratory Lab ID: LCP-006 Issue date: Sept 19, 2016 Expiry date: March 18, 2017 This letter confirms the completion

More information

Tex-614-J, Testing Epoxy Materials

Tex-614-J, Testing Epoxy Materials Overview Effective Date: January 2001 - July 2002. This method covers various test procedures for epoxy materials specified under the TxDOT Material Specification "DMS-6100, Epoxies and Adhesives." The

More information

Product Safety and Performance Evaluation

Product Safety and Performance Evaluation Product Safety and Performance Evaluation Tour Links, Inc. 5030 Seminole Boulevard St. Petersburg, FL 33708 June 30, 2011 Prepared for: Tour Links, Inc. 5030 Seminole Boulevard St. Petersburg, FL 33708

More information

Product Evaluation Report

Product Evaluation Report Product Evaluation Report PER-11044 Page 1 of 5 Initial Listing July, 2011 This Document Published By: Re-Approved May, 2018 Listed Product Flat & Raised Panel Cabinet Doors 5.2mm Industrial Panel with

More information

CONE PENETRATION TEST DATA

CONE PENETRATION TEST DATA CONE PENETRATION TEST DATA Proposed Logan Wastewater Plant Addition Logan, Utah July 30-31, 2014 Prepared for: IGES, Inc. Salt Lake City, Utah Prepared by: ConeTec, Inc. Salt Lake City, Utah August 4,

More information

MESA Cornerstone Segmental Retaining Wall Unit and Tensar Geogrid Connection Strength Testing

MESA Cornerstone Segmental Retaining Wall Unit and Tensar Geogrid Connection Strength Testing MESA Cornerstone Segmental Retaining Wall Unit and Tensar Geogrid Connection Strength Testing Prepared for Tensar Earth Technologies, Inc. 5883 Glenridge Drive, Suite 2 Atlanta, GA 3328 Prepared by National

More information

Spaceloft Insulation TECHNICAL GUIDE

Spaceloft Insulation TECHNICAL GUIDE (Click below to jump to sections.) Contents Introduction 3 Non-Combustibility and Fire Performance 4 EN 13501-1 Reaction to Fire Classification (Bodycote, Warrington Fire) ASTM E 84 Surface Burning Characteristics

More information

United States Stove Company Project # Model: KP60 AKA: AP60, VG60 Type: Pellet-Fired Room Heater May 31, 2018

United States Stove Company Project # Model: KP60 AKA: AP60, VG60 Type: Pellet-Fired Room Heater May 31, 2018 United States Stove Company Project # 18-409 AKA: AP60, VG60 Type: Pellet-Fired Room Heater May 31, 2018 ASTM E2779 Standard Test Method for Determining Particulate Matter Emissions from Pellet Heaters

More information

DMS-9203, Asphaltic Concrete Patching Material (Containerized)

DMS-9203, Asphaltic Concrete Patching Material (Containerized) Overview Effective Date: July 1999 July 2004 This specification shall govern for containerized asphaltic concrete mixture intended primarily for cool to cold, wet weather repair of small pavement areas.

More information

MTS Criterion Series 40 Specifications - Comparative

MTS Criterion Series 40 Specifications - Comparative MTS Criterion Series 40 Specifications - Comparative Model 41 Model 42 Model 43 Model 44 C41.103 C42.503 C43.104 C43.304 C43.504 C44.104 C44.304 Maximum Rated kn 1 5 10 30 50 10 30 Force Capacity lbf 220

More information

CALIBRATION REPORT. Rendered to: United States Aluminum Corp. LOCATION: Waxahachie, Texas

CALIBRATION REPORT. Rendered to: United States Aluminum Corp. LOCATION: Waxahachie, Texas CALIBRATION REPORT Rendered to: United States Aluminum Corp. LOCATION: Waxahachie, Texas Report No.: 79241.01-801-47 Calibration Date: 12/14/07 Report Date: 03/20/08 2865 Market Loop Southlake, Texas 76092

More information

21 August Mr. Raymond Pilapil Illinois EPA Bureau of Air, Compliance Section P.O. Box Springfield, Illinois

21 August Mr. Raymond Pilapil Illinois EPA Bureau of Air, Compliance Section P.O. Box Springfield, Illinois 924 Anacap Street Suite 4A Santa Barbara, CA 93101 PH 805-897-3800 FAX 805-899-8689 www.geosyntec.com 21 August 2013 Mr. Raymond Pilapil Illinois EPA Bureau of Air, Compliance Section P.O. Box 19276 Springfield,

More information

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS INSTITUTE FOR REASEARCH OF CIVIL ENGINEERING MATERIALS, STONE- AND CONCRETE CONSTRUCTION AND FIRE INTEGRITY MPA BRAUNSCHWEIG Inspection report nr (3329/2706)

More information

United States Stove Company Project # Model: Breckwell SP1000 Type: Pellet-Fired Room Heater July 25, 2018

United States Stove Company Project # Model: Breckwell SP1000 Type: Pellet-Fired Room Heater July 25, 2018 United States Stove Company Project # 18-415 Model: Breckwell SP1000 Type: Pellet-Fired Room Heater July 25, 2018 ASTM E2779 Standard Test Method for Determining Particulate Matter Emissions from Pellet

More information

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA 94804-3614 Ph. 510-236-2325; Fax 510-236-2335 E-mail info@berkeleyanalytical.com Product Sample Formaldehyde Emissions Customer & Building

More information

NDCEE Joint Service Environmental Management Conference. Cold Weather Admixture Systems (CWAS)

NDCEE Joint Service Environmental Management Conference. Cold Weather Admixture Systems (CWAS) DoD Executive Agent Office of the Assistant Secretary of the Army (Installations and Environment) Transferring Technology Solutions - Cold Weather Admixture Systems (CWAS) NDCEE 2006 Joint Service Environmental

More information

Development of a Building Block Approach for Crashworthiness Testing of Composites

Development of a Building Block Approach for Crashworthiness Testing of Composites Development of a Building Block Approach for Crashworthiness Testing of Composites Dan Adams University of Utah FAA JAMS 2018 Technical Review May 24, 2018 FAA Sponsored Project Information Principal Investigators:

More information

Tests conducted under the following industry standards for PermaFrost API ASHRAE ARI ASTM EPA ANSI UL. SINCE 1985 Quality Controlled Through Analysis

Tests conducted under the following industry standards for PermaFrost API ASHRAE ARI ASTM EPA ANSI UL. SINCE 1985 Quality Controlled Through Analysis Tests conducted under the following industry standards for PermaFrost API ASHRAE ARI ASTM EPA ANSI UL SINCE 1985 Client: Powertron LLC Requested By: Mr. Tony Sgarbi Sample: 10% PermaFrost + 90% Report

More information

DMS-9202, Asphaltic Concrete Patching Material (Stockpile Storage)

DMS-9202, Asphaltic Concrete Patching Material (Stockpile Storage) Overview Effective Date: July 1999 July 2004 This specification shall govern for an asphaltic concrete mixture intended primarily as a cool to cold weather stockpile patching mix for maintenance. It shall

More information

Applicable Requirements - NSPS Subpart JJJJ

Applicable Requirements - NSPS Subpart JJJJ Facility Name: CO Station 3 Combustion Type: 4SRB Facility HAP Status: Area Fuel Type: Natural gas RICE Owner: RICE Operator: S2C Gathering Co Acme Operating Inc. Use Type: Max. Runtime: Non-emergency

More information

ROLEC Gehäuse-Systeme GmbH Mr. Volker Borcherding Kreuzbreite 2 D Rinteln

ROLEC Gehäuse-Systeme GmbH Mr. Volker Borcherding Kreuzbreite 2 D Rinteln Reg.-Nr. DAP PL 2812.00 Labor für Umwelterprobung und Werksffprüfung Telefon +49-3 41 / 4 84 32-25 Telefax +49-3 41 / 4 84 32-14 email umwelterprobung@tzoleipzig.de Technologie Zentrum Oberflächentechnik

More information

COMMERCIAL ITEM DESCRIPTION HOSE AND HOSE ASSEMBLIES, NONMETALLIC SPRAY

COMMERCIAL ITEM DESCRIPTION HOSE AND HOSE ASSEMBLIES, NONMETALLIC SPRAY [INCH-POUND] A-A-59613 August 16, 2001 SUPERSEDING ZZ-H-521F May 28, 1993 COMMERCIAL ITEM DESCRIPTION HOSE AND HOSE ASSEMBLIES, NONMETALLIC SPRAY The General Services Administration has authorized the

More information

Fluid Sealing Association

Fluid Sealing Association Fluid Sealing Association STANDARD FSA-DSJ-401-07 SPECIFICATION FOR HIGH TEMPERATURE AND ACID RESISTANT TERPOLYMER FLUOROELASTOMER REVISED JULY, 2007 This is an editorial revision only. The standard currently

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1, 2, 3 CONTINENTAL AUTOMOTIVE SYSTEMS 2400 Executive Hills Blvd. Auburn Hills, MI 48326 Mr. David E. Swift Phone: 248 209 3813 Email: david.swift@continental-corporation.com

More information

Tel: (0) Fax: (0)

Tel: (0) Fax: (0) PETRODIST 400 CC www.pilodist.de Tel: ++ 49 (0) 2225 955910 Fax: ++ 49 (0) 2225 9559111 e-mail : info@pilodist.de GmbH Eingetragen AG Bonn HRB 12941 Bankers: Eichelnkampstraße 2 Sitz: Bonn Sparkasse KölnBonn

More information

Fluid Sealing Association

Fluid Sealing Association Fluid Sealing Association STANDARD FSA-DSJ-401-09 SPECIFICATION FOR HIGH TEMPERATURE AND ACID RESISTANT TERPOLYMER FLUOROELASTOMER REVISED OCTOBER, 2009 994 Old Eagle School Road, Suite 1019 Wayne, Pennsylvania

More information

High Temperature Marker Tag

High Temperature Marker Tag Tinley Park, IL 0487 High Temperature Marker Tag This specification is intended to outline the physical and chemical properties of PANDUIT s material for identification purposes. Printable Material Suffixes

More information

ASTM Consensus Standards The Latest in Packaging Testing. Presented by: Dhuanne Dodrill President Rollprint Packaging Products, Inc.

ASTM Consensus Standards The Latest in Packaging Testing. Presented by: Dhuanne Dodrill President Rollprint Packaging Products, Inc. ASTM Consensus Standards The Latest in Packaging Testing Presented by: Dhuanne Dodrill President Rollprint Packaging Products, Inc. ASTM Overview Established in 1898 Voluntary, Full-Consensus Standards

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTONEUM NORTH AMERICA, INC Haggerty Rd. Novi, MI Jian Pan Phone: MECHANICAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTONEUM NORTH AMERICA, INC Haggerty Rd. Novi, MI Jian Pan Phone: MECHANICAL SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AUTONEUM NORTH AMERICA, INC. 29293 Haggerty Rd. Novi, MI 48331 Jian Pan Phone: 248 324 2264 MECHANICAL Valid To: October 31, 2017 Certificate Number: 1745.02

More information

D ISM Lubricant Performance Test. Report Packet Version No. Method. Conducted For:

D ISM Lubricant Performance Test. Report Packet Version No. Method. Conducted For: D 7468 - ISM Lubricant Performance Test Report Packet Version No. Method Conducted For: V = I = N = Valid; The reference oil / non-reference oil was evaluated in accordance with the test procedure. Invalid;

More information

Update NCHRP Project 9-61 Short- and Long-Term Binder Aging Methods to Accurately Reflect Aging in Asphalt Mixtures

Update NCHRP Project 9-61 Short- and Long-Term Binder Aging Methods to Accurately Reflect Aging in Asphalt Mixtures Update NCHRP Project 9-61 Short- and Long-Term Binder Aging Methods to Accurately Reflect Aging in Asphalt Mixtures Ramon Bonaquist, P.E. Research Team Ramon Bonaquist - PI Western Research Institute Jeramie

More information

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 *

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 * SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 * PRODUCT: Polymer (Foam-Filled) Fuel Cells 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards

More information

D ISB Lubricant Performance Test. Report Packet Version No. Method. Conducted For:

D ISB Lubricant Performance Test. Report Packet Version No. Method. Conducted For: D 7484 - ISB Lubricant Performance Test Report Packet Version No. Method Conducted For: V = I = N = Valid; The reference oil / non-reference oil was evaluated in accordance with the test procedure. Invalid;

More information

PRESSURE DIFFERENTIAL AND THERMAL SHOCK/PRESSURE DIFFERENTIAL EVALUATION. B602-10, V302 and B202-1WNL Vial Variables TEST REPORT #:

PRESSURE DIFFERENTIAL AND THERMAL SHOCK/PRESSURE DIFFERENTIAL EVALUATION. B602-10, V302 and B202-1WNL Vial Variables TEST REPORT #: PRESSURE DIFFERENTIAL AND THERMAL SHOCK/PRESSURE DIFFERENTIAL EVALUATION B602-10, V302 and B202-1WNL Vial Variables TEST REPORT #: 13-1054 TESTING PERFORMED FOR: STARPLEX SCIENTIFIC, INC. 50A Steinway

More information

Pilodist. Laboratory & process technology. Knowledge & Competence

Pilodist. Laboratory & process technology. Knowledge & Competence Pilodist Laboratory & process technology Knowledge & Competence ASTM Units - Crude Oil Distillation Petrodist 100 CC Fully Automatic Distillation System according to ASTM D-2892. Processor controlled

More information

Physical Properties. Temperature Limits. Durometer 60 +/-5. Average Elongation 350% Specific Gravity 1.50 Polymer Content 20% -20 o F to +212 o F

Physical Properties. Temperature Limits. Durometer 60 +/-5. Average Elongation 350% Specific Gravity 1.50 Polymer Content 20% -20 o F to +212 o F The Advance Standard Model AW Wraparound casing end seal is manufactured of 1/8 thick neoprene rubber, assuring excellent chemical resistance and resiliency. Also included are ½ wide T304 stainless steel

More information

OFS Brands Test Facility Report No: OFSB Date: April 2, 2015 Page: 1 of 29. Test Report For: ANSI/BIFMA X Storage Units.

OFS Brands Test Facility Report No: OFSB Date: April 2, 2015 Page: 1 of 29. Test Report For: ANSI/BIFMA X Storage Units. Date: April 2, 2015 Page: 1 of 29 Test Report For: ANSI/BIFMA X5.9-2012 Storage Units FastenLink This report shall not be reproduced, except in full, without written permission from OFS Brands Quality

More information

WESTONE ONYX BLACK WEI-408B2

WESTONE ONYX BLACK WEI-408B2 WESTONE ONYX BLACK WEI-408B2 DETECTING AND ANALYZING REPORT Series Number 2012 - (FX) -020 Samples Name Westone Onyx Black Roofing Slate WEI-408B2 Entrusting Organization Shaanxi Westone Industry and Trade

More information

PRESSURE DIFFERENTIAL AND THERMAL SHOCK/PRESSURE DIFFERENTIAL EVALUATION. B ml Container (Mfg. Date , Lot # 2K15)

PRESSURE DIFFERENTIAL AND THERMAL SHOCK/PRESSURE DIFFERENTIAL EVALUATION. B ml Container (Mfg. Date , Lot # 2K15) PRESSURE DIFFERENTIAL AND THERMAL SHOCK/PRESSURE DIFFERENTIAL EVALUATION B902-10 90 ml Container (Mfg. Date 1210151, Lot # 2K15) TEST REPORT #: 12-1381 TESTING PERFORMED FOR: STARPLEX SCIENTIFIC, INC.

More information

On-Line NIR Analysis of Crude Distillation Unit

On-Line NIR Analysis of Crude Distillation Unit Application Note On-Line NIR Analysis of Crude Distillation Unit Introduction Petroleum refining is the process of separating the many compounds present in crude petroleum. The principle which is used

More information

ISO 3405 INTERNATIONAL STANDARD. Petroleum products Determination of distillation characteristics at atmospheric pressure

ISO 3405 INTERNATIONAL STANDARD. Petroleum products Determination of distillation characteristics at atmospheric pressure INTERNATIONAL STANDARD ISO 3405 Fourth edition 2011-01-15 Petroleum products Determination of distillation characteristics at atmospheric pressure Produits pétroliers Détermination des caractéristiques

More information

Draft Indian Standard Specification for Rubber Gaskets (First Revision of IS : 1984) ICS , ,

Draft Indian Standard Specification for Rubber Gaskets (First Revision of IS : 1984) ICS , , For BIS Use Only Draft Indian Standard Specification for Rubber Gaskets (First Revision of IS 11149 : 1984) ICS 23.040.80, 83.060, 83.140.50 Not to be reproduced without the permission of Last date for

More information

Concrete ASTM COMPRESSION TESTER ACCESSORIES

Concrete ASTM COMPRESSION TESTER ACCESSORIES ADR Advanced Digital Readout Menu-driven with simple data entry. Dual input and operating modes. Peak hold and auto stress calculation. RS232C output. Pace deviation bar graph for accurate load rate applications.

More information

PASS. Vincent Chow Wai Kit Manager, Chemical Laboratory

PASS. Vincent Chow Wai Kit Manager, Chemical Laboratory Recipient Email: DawnG@greaterchina-usa.com Pages: Page 1 of 6 SAMPLE INFORMATION: Description: Custom Stress Ball Assortment: - Purchase Order Number: 11866JD SKU/style No.: - Toy Co./Agency: - Factory

More information

Special Provision No. 111S12 July 2017

Special Provision No. 111S12 July 2017 AMENDMENT TO OPSS 1103, NOVEMBER 16 Special Provision No. 111S12 July 17 OPSS 1103, November 16, Material Specification for Emulsified Asphalt, is deleted in its entirety and replaced with the following:

More information

DMS ASPHALTIC CONCRETE PATCHING MATERIAL (STOCKPILE STORAGE)

DMS ASPHALTIC CONCRETE PATCHING MATERIAL (STOCKPILE STORAGE) DMS - 9202 (STOCKPILE STORAGE) EFFECTIVE DATES: AUGUST 2004 APRIL 2010. 9202.1. Description. This Specification governs for an asphaltic concrete mixture intended primarily as a cool to cold weather stockpile

More information

Comparison of IG Testing Standard. IGMA Summer Meeting August 8, 2004

Comparison of IG Testing Standard. IGMA Summer Meeting August 8, 2004 Comparison of IG Testing Standard IGMA Summer Meeting August 8, 2004 1 The Task Compare the new Harmonized standards to: Old ASTM stds. Canadian stds. CEN stds. (Europe) ISO std. (proposed) 2 The Standards

More information

Geomembrane Test Methods

Geomembrane Test Methods Appendix 2 Geomembrane Test Methods AMERICAN SOCIETY FOR TESTING AND MATERIALS (arranged by number) ASTM D-5 ASTM D-36 ASTM D-256 ASTM D-412 ASTM D-413 ASTM D-471 ASTM D-570 ASTM D-638 ASTM D-696 ASTM

More information

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces UL 2043 TEST REPORT Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces Pipe Fixings TSMI TSMI Non-metallic Tubing Channel Clip for

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 NORTHERN BALANCE AND SCALE, INC. 9556 W. Bloomington Freeway Bloomington, MN 55431 Joey Kaluser Phone: 952 881 7716 CALIBRATION Valid

More information

SPECIFICATION. Provide a bridge or parking garage joint seal that consists of either: DISTRIBUTED BY: CANADIAN CONSTRUCTION PRODUCTS

SPECIFICATION. Provide a bridge or parking garage joint seal that consists of either: DISTRIBUTED BY: CANADIAN CONSTRUCTION PRODUCTS A. General The wk shall consist of furnishing and installing a high perfmance, closed cell, prefmed seal in accdance with the details shown on the plans and the requirements of the specifications. Manufacturer

More information

FEDERAL SPECIFICATION ETHER, PETROLEUM; TECHNICAL GRADE. 1.1 Scope. This specification covers technical grade petroleum ether to be used as a solvent.

FEDERAL SPECIFICATION ETHER, PETROLEUM; TECHNICAL GRADE. 1.1 Scope. This specification covers technical grade petroleum ether to be used as a solvent. METRIC 4 May 2015 SUPERSEDING O-E-751C 10 January 2003 FEDERAL SPECIFICATION ETHER, PETROLEUM; TECHNICAL GRADE The General Services Administration has authorized the use of this federal specification by

More information

Shawal CGC Calibration Profile

Shawal CGC Calibration Profile Shawal CGC Calibration Profile Phone Number: +93 700021925, +93 748468800, +93 779015120 TABLE OF CONTENTS 1.0. INTRODUCTION 2.0 COMPANY STRUCTURE 3.0 CALIBRATION & EQUIPMENT & REPAIR SERVICES 4.0 COMPETITIVE

More information

PART X SUB PART (B): DETAILS OF STANDARDS OF VISIBLE AND GASEOUS POLLUTANTS FROM DIESEL ENGINES FOR CONSTRUCTION EQUIPMENT VEHICLES

PART X SUB PART (B): DETAILS OF STANDARDS OF VISIBLE AND GASEOUS POLLUTANTS FROM DIESEL ENGINES FOR CONSTRUCTION EQUIPMENT VEHICLES PART X SUB PART (B): DETAILS OF STANDARDS OF VISIBLE AND GASEOUS POLLUTANTS FROM DIESEL ENGINES FOR CONSTRUCTION EQUIPMENT VEHICLES Scope This part applies to the emission of visible pollutants and gaseous

More information

LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001)

LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001) RULE 346. LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001) A. Applicability The provisions of this rule shall apply to the transfer of organic liquids into an organic liquid

More information

MATERIAL SPECIFICATION FOR ORGANIC SOLVENT BASED TRAFFIC PAINT

MATERIAL SPECIFICATION FOR ORGANIC SOLVENT BASED TRAFFIC PAINT ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 1712 FEBRUARY 1991 MATERIAL SPECIFICATION FOR ORGANIC SOLVENT BASED TRAFFIC PAINT 1712.01 SCOPE 1712.02 REFERENCES 1712.03 DEFINITIONS 1712.05 MATERIALS

More information

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY LAMINATED FLOORING

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY LAMINATED FLOORING Report No. L/3193 Page 1 of 8 for EA Mimarlik Insaat Teknolojileri San.ve. Tic.Ltd.Sti 1420/3 Sokak NO. 22 Kizilkanat Silesi D Blok D.12 Alsancak Izmir Turkey Dated: 18 July 2011 LABORATORY MEASUREMENTS

More information

INVERTER APPROVAL FOR INSTALLATION IN ISRAEL

INVERTER APPROVAL FOR INSTALLATION IN ISRAEL 05.02.18 v.5 INVERTER APPROVAL FOR INSTALLATION IN ISRAEL STANDARDS APPLIED FOR SAFETY EVALUATION OF INVERTERS: AS/NZS 3100 Approval and test specification General requirements for electrical equipment

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK (part of Smithers Rapra and Ltd) Packaging Technical Services Cleeve Road Leatherhead Surrey KT22 7RU Contact: Mr G Collis Tel: +44 (0)1372 802000 Fax: +44 (0)1372 802245 E-Mail: gcollis@smithers.com Website:

More information

The purpose of this rule is to limit VOC emissions from the transfer of organic liquids.

The purpose of this rule is to limit VOC emissions from the transfer of organic liquids. RULE 4624 TRANSFER OF ORGANIC LIQUID (Adopted April 11, 1991; Amended September 19, 1991; Amended May 21, 1992; Amended December 17, 1992; Amended December 20, 2007) 1.0 Purpose The purpose of this rule

More information

SR GreenPoxy 33 / SZ 8525 Clear epoxy system for compression moulding

SR GreenPoxy 33 / SZ 8525 Clear epoxy system for compression moulding Page 1 / 8 SR GreenPoxy 33 / SZ 8525 Clear epoxy system for compression moulding High bio-based carbon content SR GreenPoxy 33 resin is outcoming from the latest innovations in bio-based chemistry. SR

More information

Electronic Materials Brochure

Electronic Materials Brochure Electronic Materials Brochure TABLE OF CONTENTS 3 Introduction to Materials 4 ISODAMP C-8000 Materials 6 ISOLOSS SL Molding Materials - Thermosets 8 CONFOR EG Foams CONFOR SC Foams ISODAMP C-8000 MATERIALS

More information

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA REPORT NUMBER: 101351744MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA TEST REPORT EVALUATION CENTER Intertek Verification Center 8431 Murphy Dr Middleton, WI 53562 x RENDERED TO Marc Doheny

More information

TEST REPORT. No. 284a/14

TEST REPORT. No. 284a/14 Labor für Umwelterprobung und Werkstoffprüfung Telefon +49 (0) 3 41 / 4 84 32-25 Telefax +49 (0) 3 41 / 4 84 32-14 E-Mail umwelterprobung@tzoleipzig.de Technologie-Zentrum für Oberflächentechnik und Umweltschutz

More information

Tex-614-J, Testing Epoxy Materials

Tex-614-J, Testing Epoxy Materials Overview Effective: August 1999 May 2000. This method covers various test procedures for epoxy materials specified under the TxDOT Material Specification DMS-6100, Epoxies and Adhesives. The test to be

More information

PRODUCT MANUAL FOR DISINFECTANT FLUID, PHENOLIC TYPE According to IS 1061: 2017

PRODUCT MANUAL FOR DISINFECTANT FLUID, PHENOLIC TYPE According to IS 1061: 2017 PM/IS 1061/1/August 2018 PRODUCT MANUAL FOR DISINFECTANT FLUID, PHENOLIC TYPE According to IS 1061: 2017 This Product Manual shall be used as reference material by all Regional/Branch Offices & licensees

More information

TEST REPORT. The following merchandise was submitted and identified by the vendor as:

TEST REPORT. The following merchandise was submitted and identified by the vendor as: Page: 1 of 13 Date: Feb 17, 2016 E-ONE MOLI ENERGY CORP. Tainan Science-Based Industry Park No.10 Dail 2nd Rd., Shan-Hwa, Tainan City, Taiwan R.O.C. Tel: 886-6-505-0666, Fax: 886-6-505-0777 http://www.molicel.com.

More information

MOBILE FILTRATION FUME CABINET

MOBILE FILTRATION FUME CABINET MOBILE FILTRATION FUME CABINET MODELS INCLUDE: MFC1000 MFC1000E MFC1000ES WITH MONITORING SYSTEM Thermoline Scientific Equipment Pty. Ltd. T/A Thermoline Scientific ABN 80 000 859 129 10-12 Ross Place.

More information

MITRAS MATERIALS GMBH

MITRAS MATERIALS GMBH MITRAS MATERIALS GMBH Friedrich-Ochs-Str. 2 92637 Weiden/Opf. Tel.: 0961 / 89-810 / 89-812 Fax: 0961 / 89-672 Directory of services L a b o r a t o r y MITRAS MATERIALS GMBH Edition 02/18 Rev. 08 page

More information

Effects of Fuel Weathering on RVP, Distillation and Oxygen Content of Ethanol and iso-butanol Blends

Effects of Fuel Weathering on RVP, Distillation and Oxygen Content of Ethanol and iso-butanol Blends Effects of Fuel Weathering on RVP, Distillation and Oxygen Content of Ethanol and iso-butanol Blends Thomas Wallner Argonne National Laboratory Jeff Wasil Bombardier Recreational Products Engine Manufacturers

More information

AR-GLAS. Tubing and Rod of Special Glass

AR-GLAS. Tubing and Rod of Special Glass Tubing and Rod of Special Glass SCHOTT is a leading international technology group in the areas of specialty glass and glass-ceramics. With more than 130 years of outstanding development, materials and

More information

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6 Test Report. AJHL1606005783FB Date: JUN.21, 2016 Page 1 of 6 IGEPA GROUP GmbH & CO., KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was / were submitted and identified on behalf of the

More information

Amendment 69 FR (20 December 2004) Section 5 Hydraulic brake hose, brake hose assemblies, and brake hose end fittings ESN270529

Amendment 69 FR (20 December 2004) Section 5 Hydraulic brake hose, brake hose assemblies, and brake hose end fittings ESN270529 Vehicle Certification Agency 1 The Eastgate Office Centre Eastgate Road Bristol BS5 6XX United Kingdom Telephone: +44 (0) 117 951 5151 Fax: +44 (0) 117 952 4103 Email: enquiries@vca.gov.uk www.dft.gov.uk/vca/

More information

Blast Protection Damper

Blast Protection Damper Protection Damper plate shown as transparent height width 250mm wide 6.35mm thick blast plate bolted to damper frame 178mm 250mm standard depth 76mm standard flange Application The damper is designed for

More information

MATERIAL SPECIFICATION FOR EMULSIFIED ASPHALT

MATERIAL SPECIFICATION FOR EMULSIFIED ASPHALT ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 1103 FEBRUARY 1996 MATERIAL SPECIFICATION FOR EMULSIFIED ASPHALT 1103.01 SCOPE 1103.02 REFERENCES 1103.03 Not Used 1103.04 Not Used 1103.05 MATERIALS

More information

Steel Door Sound Transmission Tests

Steel Door Sound Transmission Tests Steel Door Sound Transmission Tests This package details the sound transmission tests we conducted on our 1.75" thick steel doors on Aug 8-9, 01 at NWAA Labs in Elma, WA. We tested our 175C steel door

More information

Industry/PennDOT Initiative On Performance Testing. AN UPDATE January 22, 2019

Industry/PennDOT Initiative On Performance Testing. AN UPDATE January 22, 2019 Industry/PennDOT Initiative On Performance Testing AN UPDATE January 22, 2019 Outline Testing Modes A Review of Semi-Circular Bend (SCB) Test PA Industry Initiative on SCB Results & Observations Next Steps

More information

DETAIL SPECIFICATION RUBBER, FLUOROSILICONE ELASTOMER, OIL AND FUEL RESISTANT, SHEETS, STRIPS, MOLDED PARTS, AND EXTRUDED SHAPES

DETAIL SPECIFICATION RUBBER, FLUOROSILICONE ELASTOMER, OIL AND FUEL RESISTANT, SHEETS, STRIPS, MOLDED PARTS, AND EXTRUDED SHAPES INCH-POUND 11 August 2006 SUPERSEDING MIL-R-25988B 12 July 1983 DETAIL SPECIFICATION RUBBER, FLUOROSILICONE ELASTOMER, OIL AND FUEL RESISTANT, SHEETS, STRIPS, MOLDED PARTS, AND EXTRUDED SHAPES Reactivated

More information

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample Suitable for measuring gas oils, distillate fuels and diesel fuels, as specified in ASTM D975, EN590 and ISO 8217 (marine fuels). The RHEOTEK AKV-diesel is a fully automated viscometer system suitable

More information

No , Vers.1

No , Vers.1 Pag. 1 of 4 TEST REPORT No. Test performed in accordance with the standard ASTM B 117 (2003) issued by TÜV Rheinland Italia S.r.l. - Via Gavardina Trav. II, 42 I-25010 Ponte S. Marco (BS) 1. General information

More information

RAYMARK LABELS SCOPE. This Quality Assurance Specification establishes the quality standard for Tyco Raymark Labels

RAYMARK LABELS SCOPE. This Quality Assurance Specification establishes the quality standard for Tyco Raymark Labels RW 2518 Revision 1 Page 1 of 9 Date Printed 15-Apr-08 Tyco Electronics Cheney Manor, Swindon. UK RW 2518 Revision 1 RAYMARK LABELS SCOPE This Quality Assurance Specification establishes the quality standard

More information

%"!#!#%&'!# %##(%)"&#%$!!%'"%!'*%% SW 26 Street, Room 208,%! '#%# - '

%!#!#%&'!# %##(%)&#%$!!%'%!'*%% SW 26 Street, Room 208,%! '#%# - ' "#$ %"##%&'# %##(%)"&#%$ %'"%'*%%+ 11805 SW 6 Street, Room 08,% '#%# - ' Miami, Florida 33175474 T (786) 315590 F (786) 315599...//001/ # (#*+ (3,4004135 1 678 9 ' 035 ' This NOA is being issued under

More information

Cummins Turbo Engines: VpCI-126 bags vs. Competition

Cummins Turbo Engines: VpCI-126 bags vs. Competition Cummins Turbo Engines: VpCI-126 bags vs. Competition To: For: From: cc: John Curry Atlantic Packaging Corp. Quentin Davis Cummins Turbo Technology 9051 Palmetto Commerce Parkway Ladson, SC, 29456 Cortec

More information