VKS VKSA. Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

Size: px
Start display at page:

Download "VKS VKSA. Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E"

Transcription

1 Rectangular duct fans Caissons de ventilation pour gaines rectangulaires A Rechteckige Kanalventilatoren Rektangulær kanalventilator Rectangular duct fans for ventilation and air conditioning systems, mounted into a system of rectangular air ducts. Used for the air supply or extract. Not suitable for polluted air, aggressive and explosive gases. Compact, with low noise level, mounted in any position, simple access to clean an impeller. Impeller with forward curved blades made of galvanized steel. Ziehl-Abegg motorized impeller. Motor: external rotor, motor protection with built-in thermal-contact, maintenance free ball bearings. Housing: made of galvanized steel. A Sound insulation: mineral wool, 50 mm thickness. Low noise level. Rechteckige Kanalventilatoren, die für Lüftungs- und Klimaanlagen bestimmt sind, werden in das System der rechteckigen Luftführungskanäle montiert. Sie werden für Zuluft und Abluft verwendet. Nicht geeignet für die Beförderung von verschmutzter Luft, agressiven, explosiven Gasen. Kompakt, leise funktionierend, Montage in jeder beliebigen Stellung, das Flügelwerk ist leicht zur Reinigung herausnehmbar. Laufrad ist vorwärts gekrümmt, aus verzinktem Stahl. Ziehl-Abbeg motorisiertes Laufrad. Der Motor: Außenrotor, Direktantrieb, integrierter Thermokontakt- Motorschutz, dauerhafte, keine Pflege erfordernde Lager. Das Gehäuse: aus verzinktem Blech. A Schallisolation: Steinwolle, 50mm dick. Niedriges Geräuschniveau. Les caissons de ventilation pour gaines rectangulaires sont destinés aux systèmes de ventilation et de climatisation utilisant des conduits rectangulaires. Ils s utilisent en apport d air neuf ou en extraction. Ces caissons ne conviennent pas au transport d air fortement pollué, de gaz agressifs ou explosifs. Ils sont compacts, fonctionnent silencieusement et peuvent être installés dans n importe qu elle position. La turbine s enlève facilement pour l entretien. Mototurbine Ziehl-Abegg : réaction (pales incurvées vers l avant, acier galvanisé). Moteur : à rotor externe, entraînement direct avec protection thermique intégrée (PTO), roulements graissés à vie ne nécessitant pas d entretien. Enveloppe : tôle d acier galvanisée. A Isolation acoustique : laine de roche, 50 mm d épaisseur. Faible niveau de bruit. Rektangulære kanalventilatorer for ventilation og luftbehandling. Ikke velegnede for uren luft, aggressiv eller eksplosionsfarlig luft. Kompakt, lavt lydniveau, valgfri monteringsposition samt enkel adgang til rensning af ventilatorhjul. Ventilator med fremoverbøjede blade, udført i galvaniseret stål. Ventilatorhjul med indbygget Ziehl-Abegg motor. Ekstern rotormotor med indbygget termisk beskyttelse samt vedligeholdelsesfrie kuglelejer. Ventilatorhus fremstillet i galvaniseret stålplade. A Lydisoleret med 50 mm. mineraluld. Lavt lydniveau. Accessories Single phase speed controller Three phase speed controller Single phase speed controller Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E TGRV p. 138 TGRT p. 139 ETY/MTY p. 141 LJ/PG p. 150/151 SKS p. 196 FDS p. 190 EKS p

2 A Type Dimensions [mm] B B1 B2 H H1 H2 L1 400x x x x x x x x A Type Dimensions [mm] B B1 B2 B3 H H1 H2 H3 L L1 A 400x A 500x A 500x A 600x A 600x A 700x A 800x A 1000x

3 Type Accessories TGRV TGRT ETY/MTY LJ/E LJ/PG SKS FDS EKS /A 400x200-4 L1 2-2,5 40x20 40x x200 /A 400x200-4 L x20 40x x200 /A 500x250-4 L x25 50x x250 /A 500x250-4 L x25 50x x250 /A 500x300-4 L x30 50x x300 /A 500x300-4 L x30 50x x300 /A 500x300-6 L1 3-2,5 50x30 50x x300 /A 600x300-4 L x30 60x x300 /A 600x300-4 L x30 60x x300 /A 600x300-6 L1 3-2,5 60x30 60x x300 /A 600x300-6 L x30 60x x300 /A 600x350-4 L x35 60x x350 /A 600x350-4 L x35 60x x350 /A 600x350-6 L x35 60x x350 /A 700x400-4 L x40 70x x400 /A 700x400-6 L x40 70x x400 /A 800x500-4S L x50 80x x500 /A 800x500-4 L x50 80x x500 /A 800x500-6 L x50 80x x500 /A 800x500-8 L x50 80x x500 /A 1000x500-4S L x50 100x x500 /A 1000x500-4 L x50 100x x500 /A 1000x500-6 L x50 100x x500 /A 1000x500-8 L x50 100x x500 56

4 /A 400x200-4 L1 400x200-4 L1 Lwa total, Lwa, /A 400x200-4 L3 Inlet Outlet surrounding A surrounding Measured at 452 m 3 /h, 217 Pa 400x200-4 L3 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 524 m 3 /h, 214 Pa 400x200-4 L1 400x200-4 L3 Voltage/Frequency [V/Hz] 230/50 400/50 [kw] 0,264 0,241 Current [A] 1,35 0,44 Speed [min -1 ] Max. airflow [m 3 /h] Min./Max. air temperature [ C] -25 / / 70 Weight [kg] 14 / / 21 Wiring diagram No. 1 No. 2 Protection class: motor IP-54 IP-44 terminal box IP-55 IP-55 Comply with ERP

5 /A 500x250-4 L1 500x250-4 L1 Lwa total, Lwa, Inlet /A 500x250-4 L3 Outlet surrounding A surrounding Measured at 882 m 3 /h, 311 Pa 500x250-4 L3 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 1058 m 3 /h, 301 Pa /A 500x300-4 L1 500x300-4 L1 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 1027 m 3 /h, 380 Pa 58

6 /A 500x300-4 L3 500x300-4 L3 Lwa total, Lwa, /A 500x300-6 L1 Inlet Outlet surrounding A surrounding Measured at 1449 m 3 /h, 378 Pa 500x300-6 L1 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 1385 m 3 /h, 109 Pa 500x250-4 L1 500x250-4 L3 500x300-4 L1 500x300-4 L3 500x300-6 L1 Voltage/Frequency [V/Hz] 230/50 400/50 230/50 400/50 230/50 [kw] 0,50 0,56 0,63 1,007 0,267 Current [A] 2,3 0,95 3,0 2,01 1,15 Speed [min -1 ] Max. airflow [m 3 /h] Min./Max. air temperature [ C] -25 / / / / / 50 Weight [kg] 16 / / / / / 28 Wiring diagram No. 1 No. 2 No. 1 No. 2 No. 1 Protection class: motor IP-54 IP-54 IP-54 IP-54 IP-54 terminal box IP-55 IP-55 IP-55 IP-55 IP-55 Comply with ERP

7 /A 600x300-4 L1 /A 600x300-4 L3 600x300-4 L1 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 1417 m 3 /h, 455 Pa 600x300-4 L3 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 1686 m 3 /h, 483 Pa /A 600x300-6 L1 600x300-6 L1 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 1985 m 3 /h, 100 Pa 60

8 /A 600x300-6 L3 600x300-6 L3 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 1744 m 3 /h, 125 Pa 600x300-4 L1 600x300-4 L3 600x300-6 L1 600x300-6 L3 Voltage/Frequency [V/Hz] 230/50 400/50 230/50 400/50 [kw] 1,011 1,50 0,422 0,378 Current [A] 5,10 2,60 1,8 0,75 Speed [min -1 ] Max. airflow [m 3 /h] Min./Max. air temperature [ C] -25 / / / / 40 Weight [kg] 29 / / / / 32 Wiring diagram No. 1 No. 2 No. 1 No. 2 Protection class: motor IP-54 IP-54 IP-54 IP-54 terminal box IP-55 IP-55 IP-55 IP-55 Comply with ERP /A 600x350-4 L1 600x350-4 L1 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 2157 m 3 /h, 580 Pa 61

9 /A 600x350-4 L3 600x350-4 L3 Lwa total, Lwa, /A 600x350-6 L3 Inlet Outlet surrounding A surrounding Measured at 2193 m 3 /h, 600 Pa 600x350-6 L3 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 2760 m 3 /h, 100 Pa /A 700x400-4 L3 700x400-4 L3 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 2845 m 3 /h, 824 Pa 62

10 /A 700x400-6 L3 700x400-6 L3 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 3652 m 3 /h, 182 Pa 600x350-4 L1 600x350-4 L3 600x350-6 L3 700x400-4 L3 700x400-6 L3 Voltage/Frequency [V/Hz] 230/50 400/50 400/50 400/50 400/50 [kw] 2,249 2,353 0,739 3,49 1,043 Current [A] 10,3 4,03 1,5 6,0 2,0 Speed [min -1 ] Max. airflow [m 3 /h] Min./Max. air temperature [ C] -25 / / / / / 40 Weight [kg] 36 / / 47 24/31 62 / / 39 Wiring diagram No. 1 No. 2 No. 2 No. 2 No. 2 Protection class: motor IP-54 IP-54 IP-54 IP-54 IP-54 terminal box IP-55 IP-55 IP-55 IP-55 IP-55 Comply with ERP /A 800x500-4 L3 800x500-4 L3 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 4129 m 3 /h, 660 Pa 63

11 /A 800x500-6 L3 800x500-6 L3 Lwa total, Lwa, /A 800x500-8 L3 Inlet Outlet surrounding A surrounding Measured at 6622 m 3 /h, 100 Pa 800x500-8 L3 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 3893 m 3 /h, 130 Pa 800x500-4 L3 800x500-6 L3 800x500-8 L3 Voltage/Frequency [V/Hz] 400/50 400/50 400/50 [kw] 4,745 2,6 0,865 Current [A] 8,10 5,01 1,65 Speed [min -1 ] Max. airflow [m 3 /h] Max. air temperature [ C] -25 / / / 40 Weight [kg] 85 / / / 70 Wiring diagram No. 2 No. 2 No. 2 Protection class: motor IP-54 IP-54 IP-54 terminal box IP-55 IP-55 IP-55 Comply with ERP

12 /A 1000x500-4 L3 1000x500-4 L3 Lwa total, Lwa, /A 1000x500-6 L3 Inlet Outlet surrounding A surrounding Measured at 6131 m 3 /h, 801 Pa 1000x500-6 L3 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 6775 m 3 /h, 101 Pa /A 1000x500-8 L x500-8 L3 Lwa total, Lwa, Inlet Outlet surrounding A surrounding Measured at 4380 m 3 /h, 130 Pa 65

13 1000x500-4 L3 1000x500-6 L3 1000x500-8 L3 Voltage/Frequency [V/Hz] 400/50 400/50 400/50 [kw] 4,806 2,787 1,14 Current [A] 8,10 5,2 2,40 Speed [min -1 ] Max. airflow [m 3 /h] Max. air temperature [ C] -25 / / / 40 Weight [kg] 88 / / / 71 Wiring diagram No. 2 No. 2 No. 2 Protection class: motor IP-54 IP-54 IP-54 terminal box IP-55 IP-55 IP-55 Comply with ERP Wiring diagram No. 1 (1~) U 1 - brown U 2 - blue Z 1 - black Z 2 - orange TK - white PE - green-yellow Wiring diagram No. 2 (Y - 3~) U 1 - brown U 2 - red V 1 - blue V 2 - grey W 1 - black W 2 - orange TK - white PE - green-yellow Wiring diagram No. 2 ( 3~) U 1 - brown U 2 - red V 1 - blue V 2 - grey W 1 - black W 2 - orange TK - white PE - green-yellow Wiring diagram No. 3 ( 3~) U 1 - brown U 2 - red V 1 - blue V 2 - grey W 1 - black W 2 - orange TK - white PE - green-yellow 66

Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E Rectangular duct fans Caissons de ventilation pour gaines rectangulaires Rechteckige Kanalventilatoren Rektangulær kanalventilator Rectangular ducts fans for ventilation and air conditioning systems, mounted

More information

VKA VKAS VKA VKAS. Mounting clamp Guard grille Back draft shutter Circular duct silencer

VKA VKAS VKA VKAS. Mounting clamp Guard grille Back draft shutter Circular duct silencer Circular duct fans Ventilateurs pour gaines circulaires Rohrventilatoren Runde kanalventilatorer Circular duct fans are used for air supply or extract in ventilation and air conditioning systems. Are mounted

More information

VKS VKSA. Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

VKS VKSA. Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E Rectangular duct fans Caissons de ventilation pour gaines rectangulaires Rechteckige Kanalventilatoren Прямоугольные канальные вентиляторы Rectangular duct fans for ventilation and air conditioning systems,

More information

VKS VKS VKS VKSA VKSA VKS VKS VKSA VKSA

VKS VKS VKS VKSA VKSA VKS VKS VKSA VKSA Caissons de ventilation pour gaines rectangulaires Rechteckige Kanalventilatoren Прямоугольные канальные вентиляторы for ventilation and air conditioning systems, mounted into a system of rectangular air

More information

NEW! Mounting clamp Guard grille Back draft shutter Circular duct silencer

NEW! Mounting clamp Guard grille Back draft shutter Circular duct silencer VKAP 3. NEW! Circular duct fans Ventilateurs pour gaines circulaires Rohrventilatoren Runde kanalventilatorer Circular duct fans are used for air supply or extract in ventilation and air conditioning systems.

More information

VSV/VSVI. Roof fans. Tourelles. Dachventilatoren. Tagventilatorer VSV VSVI ROOF FANS

VSV/VSVI. Roof fans. Tourelles. Dachventilatoren. Tagventilatorer VSV VSVI ROOF FANS VSV -70 VSVI 3-70 Roof fans Tourelles Dachventilatoren Tagventilatorer Roof fans with vertical discharge are used to extract air from different premises. Motorised impeller is protected with a meshwork

More information

VKA VKAS VKA VKAS. Mounting clamp Guard grille Back draft shutter Circular duct silencer

VKA VKAS VKA VKAS. Mounting clamp Guard grille Back draft shutter Circular duct silencer S Circular duct fans Ventilateurs pour gaines circulaires Rohrventilatoren Круглые канальные вентиляторы Circular duct fans are used for air supply or extract in ventilation and air conditioning systems.

More information

VSA. Roof fans. Dachventilatoren. Roof fans

VSA. Roof fans. Dachventilatoren. Roof fans Dachventilatoren Dachventilatoren, für Abluft bestimmt. Nicht geeignet für die Beförderung von verschmutzter Luft, aggressiven, explosiven Gasen. Laufrad ist rückwärts gekrümmt, aus Kunststoff oder verzinktem

More information

VSA. Roof fans. Tourelles. Dachventilatoren. Крышные вентиляторы. Roof fans

VSA. Roof fans. Tourelles. Dachventilatoren. Крышные вентиляторы. Roof fans Tourelles Dachventilatoren Крышные вентиляторы with horizontal discharge are used to extract air from different premises. Easy access to clean an impeller. ot suitable for polluted air, aggressive and

More information

KF T120. Kitchen fans. Caisson de ventilation. Küchenabluftboxen. Boksventilator KITCHEN FANS

KF T120. Kitchen fans. Caisson de ventilation. Küchenabluftboxen. Boksventilator KITCHEN FANS Kitchen fans Caisson de ventilation Küchenabluftboxen Boksventilator Kitchen exhaust units are used for installation where the air is slightly greasy or the air temperature is up to 120 C. Unit has a swing-out

More information

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller. VKS VKSA Features Power supply Temperature range 400x200 mm to 1000x500 mm flanges; Airflow up to 9200 m 3 /h; Can be mounted on floors, walls or ceilings; Forward-curved galvanized steel impeller; Cost-effective;

More information

valymui. - - Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

valymui. - - Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E Rectangular duct fans Rectangular ducts fans for ventilation and air conditioning systems, mounted into a system of rectangular air ducts. Used for the air supply or extract. Not suitable for polluted

More information

VSV. Stoginiai ventiliatoriai. Roof fans. Dachventilatoren. Крышные вентиляторы. Roof fans

VSV. Stoginiai ventiliatoriai. Roof fans. Dachventilatoren. Крышные вентиляторы. Roof fans Stoginiai ventiliatoriai Dachventilatoren Крышные вентиляторы Stoginiai ventiliatoriai, naudojami oro ištraukimui iš patalpos. Sparnuotė uždengta tinklo grotelėmis, apsaugančiomis ją nuo pašalinių daiktų,

More information

KUB T120. Kitchen fans. Caisson de ventilation. Küchenabluftboxen. Extractor de cocina KITCHEN FANS

KUB T120. Kitchen fans. Caisson de ventilation. Küchenabluftboxen. Extractor de cocina KITCHEN FANS Kitchen fans Caisson de ventilation Küchenabluftboxen Extractor de cocina Kitchen exhaust units are used for installation where the air is slightly greasy or the air temperature is up to 120 C. Typical

More information

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases. VSV VSVI Features Power supply Temperature range Sizes Construction Installation Speed control options 9 sizes; Airflow up to 5300 m 3 /h; Vertical exhaust; Backward-curved plastic or galvanized steel

More information

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille. VKAP 3. Features Power supply Temperature range Diameter - 1 mm to 315 mm; Airflow up to 137 m 3 /h; Easily mounted in any position; Backward-curved impeller; Low ambient temperatures; Cost-effective.

More information

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS Circular duct fans VKA Circular duct fans are used for air supply or extract in ventilation and air conditioning systems. Are mounted into a system of round air ducts. Can be installed in any position.

More information

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS Circular duct fans VKA Circular duct fans are used for air supply or extract in ventilation and air conditioning systems. Are mounted into a system of round air ducts. Can be installed in any position.

More information

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases. VSA 3. ROOF FAS Features Power supply Temperature range 4 sizes; Airflow up to 117 m 3 /h; Horizontal exhaust; Backward-curved impeller; ost-effective. 23V/5Hz/1f. From -4 up to 4/65. Sizes 19 S, 19, 22

More information

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille. Application Features Power supply Circular duct fans are used in low-to medium-pressure ducted systems. Fans are suitable for air supply or exhaust of residential buildings, warehouses, bathrooms, lavatories,

More information

KF T120. Kitchen fans. Wentylatory kuchenne KITCHEN FANS

KF T120. Kitchen fans. Wentylatory kuchenne KITCHEN FANS KF T120 Kitchen fans Wentylatory kuchenne Kitchen exhaust units are used for installation where the air is slightly greasy or the air temperature is up to 120 C. Unit has a swing-out door for easy inspection

More information

Controller for electrical heater. Controller for electrical heater EKR 15.1P SKG

Controller for electrical heater. Controller for electrical heater EKR 15.1P SKG Air handling units Centrales de traitement d air simple flux Lüftungsgeräte Приточные агрегаты Low noise level. Adjustable voltage fan control. Electrical or water heater. Easily removable inspection cover.

More information

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h SOUND-INSULATED KITCHEN FAN Series device. The impeller is mounted on the motor shaft and is balanced statically and dynamically. The motor has F class motor winding insulation and ingress protection rating.

More information

Thermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection

Thermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection General Systemair thermo fans have been developed for the use in exhaust air systems where media with increased temperatures have to be transported. The special design allows a reliable operation also

More information

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence Explosion proof fans General Systemair explosion proof fans have been developed to be used in effective supply and exhaust air systems allocated to category 2 (zone 1) and category 3 (zone 2) in explosion

More information

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance

More information

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1 INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings! 1. Read all instructions.

More information

Hochleistungs-Radialventilator im Kompaktgehäuse RF..P. High performance centrifugal fan in a compact housing RF..P. Anwendung.

Hochleistungs-Radialventilator im Kompaktgehäuse RF..P. High performance centrifugal fan in a compact housing RF..P. Anwendung. Einflutiger Trommelläufer-Radialventilator mit hoher Leistungsdichte. Drehstrom-synchron-ußenläufermotor im Laufrad integriert. Dadurch kompakte auweise und optimale Motorkühlung. Durch -polige Drehzahl

More information

MOONRING 1.5 MOONRING 3

MOONRING 1.5 MOONRING 3 INSTALLATION INSTRUCTIONS MOONRING 1.5 MOONRING 3 MR1.5 & MR3 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings!

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

INSTALLATION INSTRUCTION Bollard Light 12V

INSTALLATION INSTRUCTION Bollard Light 12V Bollard Light 12V 6611/6621/6631/6641/6651 SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation

More information

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range

More information

Single-inlet centrifugal fans

Single-inlet centrifugal fans CE 200-280 4-pole Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable CE fans are easy to install. Fans in this series have impellers with forward-curved

More information

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity 400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,

More information

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing SAFETY INSTRUCTIONS IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance

More information

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting AXIAL FANS Series VENTS OV Series VENTS OVK Series VENTS Low pressure axial fans in the steel casing with the air capacity up to 122 m 3 /h for wall mounting Low pressure axial fans in the steel casing

More information

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable KD High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable Electrical accessories S-ET p. 341 The KD series have external rotor

More information

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F SAFETY S IMPORTANT SAFETY INFORMATION SUITABLE FOR DRY OR DAMP LOCATIONS. NOT FOR USE WITH PHASE CUT DIMMERS. Risk of shock. Disconnect power before installation. DANGER CONVIENT AUX EMPLACEMENTS HUMIDES.

More information

ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION

ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION 95 METAL TUBE FANS - ROPERA EC FEATURES mm to 355 mm diameter Air flow up to.56 m 3 /s Static pressures up to 7 Pa Casing - galvanized sheet steel Backward curved impeller Easy electrical connection via

More information

Sentinel D-Box Single Fan

Sentinel D-Box Single Fan Sentinel D-Box Single Fan Duct size to 5mm Performance - Airflow.1 to 1.6m 3 /s Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Aluzinc contstruction suitable for

More information

- Tel.: Fax :

- Tel.: Fax : POMA 230V/50Hz Grâce à un corps de pompe en plastique dont la teneur en fibre a été légèrement renforcée (FRP) et à une couverture supérieure, la pompe peut résister à l abrasion et à la corrosion et nécessite

More information

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular

More information

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot CENTRIFUGAL IN-LINE FANS Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a pre-wired wiring junction

More information

KV sileo 100 M. Circular duct fans. Circular duct fans

KV sileo 100 M. Circular duct fans. Circular duct fans KV sileo 100 M Speed-controllable Integral thermal contacts Can be installed in any position Can be installed outdoors Maintenance-free and reliable Electrical accessories RE p. 20 The K series is designed

More information

Inside Front cover White

Inside Front cover White TUBE FAN Inside Front cover White INDEX INTRODUCTION PERFORMANCE GRAPHS TECHNICAL DATA DIMENSIONS pages - 3 - ACOUSTIC DATA - SOUND PRESSURE LEVEL ELECTRICAL DETAILS 3 4 Index back side white Introduction

More information

Sentinel D-Box Twin Fan

Sentinel D-Box Twin Fan Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc

More information

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C BACKWARD CURVED CENTRIFUGAL FANS CMRT Series 80 C Continuous operation Range of single inlet direct drive centrifugal fans designed for continuous extraction of air stream up to 80ºC. Casings are manufactured

More information

In-line rectangular fans. Technical Catalogue

In-line rectangular fans. Technical Catalogue In-line rectangular fans Technical Catalogue Overview IN-LINE RECTANGULAR FANS IRB / IRBS IRB and IRBS are a compact series of centrifugal type exhaust and supply in-line duct fans for air conditioning

More information

Filters for fixed installations

Filters for fixed installations CYCLONE FU MECHANICAL FILTERS The FU are especially intended for filtration of dusts and heavy particles bigger than 5 microns. Centrifugal filtration is used for grinding, sanding, oxycut, all heavy,

More information

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G THT/HATCH High-powered ventilators with motorised opening and equipped with a roof fan, for smoke extraction in the event of a fire, 400ºC/2h High-powered ventilators with roof fan and motorised opening.

More information

HIGH-POWERED VENTILATORS

HIGH-POWERED VENTILATORS HIGH-POWERED VENTILATORS WITH ROOF FANS 400ºC/2h The THT/HATCH series was designed using high-powered ventilator technology for smoke extraction in the event of a fire, and is equipped with THT series

More information

RIRS H. AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit wärmerückgewinnung

RIRS H. AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit wärmerückgewinnung AHU with heat recovery Centrales de traitement d air avec récupération de chaleur Lüftungsgeräte mit wärmerückgewinnung Вентиляционные агрегаты с рекуперацией тепла Air handling units RIRS have high efficiency

More information

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame Installation Guide Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame BEFORE YOU BEGIN Read these instructions completely and carefully. RISK OF ELECTRIC SHOCK Turn power off before

More information

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller. TSA TSAT CJTSA TSA: Single inlet, belt-driven centrifugal fans with shaft outlet and forward-curved impeller. TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors, a set of pulleys

More information

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1. xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof

More information

TCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range.

TCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range. N OU VE A U Approved F400 10 (400 C 10 mn) CE marked Special range for speed variation VAR Easy installation and maintenance Low sound level Electrical accessories and relay box mounted wired New vertical

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE CENTRIFUGAL FANS ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 73-16 CENTRIFUGAL FANS CONTENT PAGE 1. CENTRIFUGAL

More information

NEW Acoustic In-Line Fans (ACQ)

NEW Acoustic In-Line Fans (ACQ) NEW Acoustic In-Line Fans (ACQ) Acoustically treated housing, Class O rated, sandwich construction selected for maximum noise absorption Motors protected to IP44 Motor insulation Class B Maximum operating

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

Installation Instructions

Installation Instructions Installation Instructions FHEZ10A24 FHEZ17A48 Page 1 of 7 IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 1. Do not mount near gas or electric heaters. 2. Do not attempt to service the battery.

More information

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Multifunctional 400ºC/2h and 300ºC/2h roof fans HTMF Multifunctional 400ºC/2h and 300ºC/2h roof fans Multifunctional 400ºC/2h ceiling fans to work inside fire danger zones, designed for smoke extraction in industrial or similar buildings. 0370-CPR-0544

More information

NEW Slimpak EC Box Fan (SLPT EC)

NEW Slimpak EC Box Fan (SLPT EC) NEW Slimpak EC Box Fan (SLPT EC) Compact low profile design Duct Sizes 100 500mm Performance - Airflow 0.01 to 1.2m 3 /s, Pressure up to 650Pa Latest energy saving EC/DC motors Internal mounting IPX2 Manufactured

More information

VWR FOR SIEVING. Test sieve shakers and accessories. Ultrasonic sieving systems. Sample splitters. Test sieves. Standards.

VWR FOR SIEVING. Test sieve shakers and accessories. Ultrasonic sieving systems. Sample splitters. Test sieves. Standards. VWR FOR SIEVING Test sieve shakers and accessories Ultrasonic sieving systems Sample splitters Test sieves Standards Ultrasonic baths Useful accessories Available from P:0800 34 24 66 www.bio-strategy.com

More information

MAXLITE RKT LED Retrofit Kit

MAXLITE RKT LED Retrofit Kit MAXLITE RKT LED Retrofit Kit Description and Intended Use The RKT LED Retrofit Kit is a high performance LED Fixture upgrade kit designed to replace the original components inside 2 x2 and 2 x4 fluorescent

More information

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered Comfort ventilation Self-supporting casing with lacquered finish as standard Air intake or exhaust operation Simplified access to internal components ErP READY Air flow: 500 to 35 000 m 3 /h Use ventilation

More information

VEKA. Oro tiekimo agregatai. Air handling units. Lüftungsgeräte. Приточные агрегаты. Air handling units

VEKA. Oro tiekimo agregatai. Air handling units. Lüftungsgeräte. Приточные агрегаты. Air handling units Oro tiekimo agregatai Lüftungsgeräte Приточные агрегаты Mažas triukšmo lygis Reguliuojamo greičio ventiliatorius (įtampos keitimas) Elektrinis arba vandeninis šildytuvas Lengvai nuimamas dangtis patikrinimui

More information

CMR/EW EFFICIENT WORK

CMR/EW EFFICIENT WORK CMR/EW AC VARIABLE SPEED DRIVE VSD: Variable Speed Drive.. VSD1/A-RFM. VSD3/A-RFT Supply on request CONTROL Supply optional accesory SUPPLY VSD1/A-RFM: 220-240 V 50/60 Hz VSD3/A-RFT: 380-415 V 50/60 Hz

More information

Mobile Crane/Grue mobile LTM

Mobile Crane/Grue mobile LTM Mobile Crane/Grue mobile LM 1090-4.2 Preliminary Préliminaire ALL-ROUNDER Ready for anything max ft 110 USt 197 ft 203 ft ft 249 ft Mobile Crane/Grue mobile LM 1090-4.2 197 ft NZK K 31 ft 52 ft m 8.4 ft

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

OTA. Oro tiekimo agregatai. Air handling units. Lüftungsgeräte. Приточные агрегаты. Air handling units

OTA. Oro tiekimo agregatai. Air handling units. Lüftungsgeräte. Приточные агрегаты. Air handling units Oro tiekimo agregatai Lüftungsgeräte Приточные агрегаты Žemas triukšmo lygis Reguliuojamo greičio ventiliatorius (įtampos keitimas) Elektrinis šildytuvas Lengvai nuimamas dangtis patikrinimui Filtrų dėžė

More information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION UR Series LED Upgrade Kit Includes: 24" Linear Option IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL

More information

CENTRIFUGAL IN-LINE FANS VENT Series

CENTRIFUGAL IN-LINE FANS VENT Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a prewired wiring junction box and a robust mounting foot.

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation CJBD/AL CJBD/ALS CJBD/ALF CJBX/AL CJBX/ALS CJBX/ALF VENTILATION UNITS WITH ALUMINIUM PROFILES According EU Regulation CJBD/AL CJBD/ALS CJBD/ALF CJBD/AL: Soundproofed ventilation units with profiles in

More information

Oil Levels & Windows. Niveaux d'huile et Voyants. Ölstandsanzeiger & Ölaugen

Oil Levels & Windows. Niveaux d'huile et Voyants. Ölstandsanzeiger & Ölaugen Oil Levels & Windows Niveaux d'huile et Voyants Ölstandsanzeiger & Ölaugen Oil Levels and Windows These units are used in industry to visually check the fluid level within a reservoir or gearbox. Vertical

More information

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa. Oakland, INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5 LP3.5 Suspended LED A 1035 22nd Avenue, Unit 1 n CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings! 1. Read all instructions.

More information

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information. In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V

More information

ACCESSORIES FOR DUCT FANS

ACCESSORIES FOR DUCT FANS FOR DUCT FANS Duct fan Clamp Filter box Silencer Electric heater Duct fans are mostly used in low-to medium-pressure ducted systems with additional components such as heaters, filter boxes, dampers, etc.

More information

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range Twin and Single Inline Fans Offers a range of flexible installation and application options, including auto-changeover on the Twin range 2 Version 3.1 Breathing Buildings Inline Box Fans Demand Control

More information

Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER

Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER Roof Extract Fans Ventilation Hoods Smoke Extract Fans DV DLH ER Summary... Seite Roof Extract Fans DV Product review... Summary data sheet...

More information

supplied in Form (B) configuration. Airflow over Impeller- Motor.

supplied in Form (B) configuration. Airflow over Impeller- Motor. CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,

More information

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB and IRBS are a compact series of centrifugal type exhaust and supply in-line duct fans for air conditioning systems. They

More information

RECOMMENDED TOOLS AND CHECKERS

RECOMMENDED TOOLS AND CHECKERS RECOMMENDED TOOLS AND CHECKERS Page RECOMMENDED TOOLS AND CHECKERS........... 2 4 : An impact wrench can be used with tools with this mark. As tools without this mark are meant to be operated manually,

More information

Section 4. Axial Fans - Section 4

Section 4. Axial Fans - Section 4 Axial Flow Fans Section 4 Fläkt Woods offers a wide range of axial flow fans for general air movement and special applications such as emergency high temperature smoke extract and pressurisation. ATEX

More information

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil Integreret Combi Cooler system Energieffektiv ventilation og køling FCUA Fancoil DESCRIPTION The FCU(A,F) fan coil unit is a highperformance, cost-effective and compact solution for the cooling of technical

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting. AXIAL FANS Series VENTS OV Series VENTS OVK Series VENTS Low pressure axial fans in the steel casing with the air capacity up to 11900 m 3 /h for wall mounting. Low pressure axial fans in the steel casing

More information

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels KAT DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels KAT Series DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels Kruger Ventilation Industries certifies that the KAT series : version S and - model 9-7 to

More information

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB Applications The CMT-CMB range of fans are suitable for many general and OEM ventilation applications where the extract of nonhazardous heated air is required. The

More information

ROOF FAN ROOFMASTER STEC

ROOF FAN ROOFMASTER STEC AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...

More information

SKU:AB4109. Heavy Duty Ball Valve with Pneumatic actuator

SKU:AB4109. Heavy Duty Ball Valve with Pneumatic actuator SKU:AB4109 VOLT Heavy Duty Ball Valve with Pneumatic Actuator VOLT Heavy Duty Kugelhahn mit pneumatischem Antrieb VOLT Válvula de bola de servicio pesado con actuador neumático VOLT Heavy Duty Ball Valve

More information

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and

More information

FITTING INSTRUCTIONS FOR PKS0057SI KICKSTAND SHOE MV Augusta F

FITTING INSTRUCTIONS FOR PKS0057SI KICKSTAND SHOE MV Augusta F FITTING INSTRUCTIONS FOR PKS0057SI KICKSTAND SHOE MV Augusta F4 1000 04- Please note that the way the kit is packed does not necessarily represent the way of mounting to the bike. THE PARTS SHOWN MAY BE

More information

ALTI-NEXIS V OPERATING LIMITS APPLICATIONS ADVANTAGES. Flow rates up to: 320 m 3 /h Delivery head up to: Maximum operating pressure:

ALTI-NEXIS V OPERATING LIMITS APPLICATIONS ADVANTAGES. Flow rates up to: 320 m 3 /h Delivery head up to: Maximum operating pressure: OPERATING LIMITS Flow rates up to: 32 m 3 /h Delivery head up to: Maximum operating pressure: 24 m CE* 16 bar option 25 bar* Maximum water temperature: 7 C Ambient temperature: 4 C DN threaded manifold:

More information

Series VENTS OVК. Axial fans of low pressure in steel case with the efficiency. wall-mounted assembly.

Series VENTS OVК. Axial fans of low pressure in steel case with the efficiency. wall-mounted assembly. AXIAL FAN Series Series К Series Axial fans of low pressure in steel case with the efficiency up to 11900 m 3 /h for a wall-mounted assembly Axial fans of low pressure in steel case with the efficiency

More information

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS Cabinet Fan SV-1 INDEX INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART pages 01 02 03 04 DIMENSION SHEET - SINGLE CABINET FANS DIMENSION SHEET - TWIN CABINET FANS PERFORMANCE GRAPH WIRING

More information

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced. LOW PRESSURE CENTRIFUGAL FANS CBM Small Series Range of single and double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel and protected against corrosion by a

More information

Checkout motorized drums catalog

Checkout motorized drums catalog Innovation driver Designed and made in FRANCE Checkout motorized drums catalog www.sirem.fr Motorized drums for Checkout by SIREM The supermarket checkouts are carefully designed so as to enhance the comfort

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

FITTING INSTRUCTIONS FOR BLP0032SI REAR FOOTREST BLANKING PLATES YAMAHA MT

FITTING INSTRUCTIONS FOR BLP0032SI REAR FOOTREST BLANKING PLATES YAMAHA MT FITTING INSTRUCTIONS FOR BLP0032SI REAR FOOTREST BLANKING PLATES YAMAHA MT-07 2014- Please note that the way the kit is packed does not necessarily represent the way of mounting to the bike THE PARTS SHOWN

More information