SM24A. Technical data. Dimensions [mm]
|
|
- Evangeline Shepherd
- 5 years ago
- Views:
Transcription
1 SM24A Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services orque 2Nm Nominal voltage AC/DC 24V Electrical data Nominal voltage AC 24V, 5/6Hz / DC 24V AC V / DC V nominal torque.2w 4VA Cable m, 3 x.75mm² Functional data orque (nominal torque) Min. nominal voltage Direction of rotation Reversible with switch resp. adjustable mechanical end stops Running time 5s / 9 Safety Protection class III Safety extra-low voltage / UL Class 2 Supply CE according to 24/8/EC Certification culus according to UL 673-A and UL and CAN/CSA E673-:2 Certified to IEC/EN 673- and IEC/EN Mode of operation ype.8kv Ambient temperature range C Non-operating temperature C -free Dimensions / Dimensions See «Dimensions» Approx..kg 39 V Subject to modification ) ) 2 ) CrNi (INOX)
2 SM24A-S Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services orque 2Nm Nominal voltage AC/DC 24V with integrated auxiliary switch Electrical data Nominal voltage AC 24V, 5/6Hz / DC 24V AC V / DC V nominal torque.2w 4VA x SPD, ma...3 (.5) A, AC 25V (...% adjustable) Motor Cable m, 3 x.75mm² Cable m, 3 x.75mm² Functional data orque (nominal torque) Min. nominal voltage Direction of rotation Reversible with switch resp. Running time 5s / 9 Safety Protection class III Safety extra-low voltage / UL Class 2 Supply CE according to 24/8/EC Certification culus according to UL 673-A and UL and CAN/CSA E673-:2 Certified to IEC/EN 673- and IEC/EN Mode of operation ype.8kv Ambient temperature range C Non-operating temperature C -free Dimensions / Dimensions See «Dimensions» Approx..2kg ) ) 2 ) CrNi (INOX) V Subject to modification
3 SM24A-SR Modulating damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services orque 2Nm Nominal voltage AC/DC 24V Control: Modulating DC ()2...V Position feedback DC 2...V Electrical data Nominal voltage AC 24V, 5/6Hz / DC 24V AC V / DC V nominal torque.4w 4VA Cable m, 4 x.75mm² Functional data orque (nominal torque) Min. nominal voltage Control Control signal Y Operating range DC ()2...V, typical input impedance kω DC 2...V Position feedback (Measuring voltage U) DC 2...V, max. ma Position accuracy ±5% Direction of rotation Reversible with switch / Direction of motion at Y = V In switch position resp. Running time 5s / 9 Safety Protection class III Safety extra-low voltage / UL Class 2 Supply CE according to 24/8/EC Certification culus according to UL 673-A and UL and CAN/CSA E673-:2 Certified to IEC/EN 673- and IEC/EN Mode of operation ype.8kv Ambient temperature range C Non-operating temperature C -free Dimensions / Dimensions See «Dimensions» Approx..kg 39 V Subject to modification ) ) 2 ) CrNi (INOX)
4 SM23A Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services orque 2Nm Nominal voltage AC...24V Electrical data Nominal voltage AC...24V, 5/6Hz AC V nominal torque.6w 6VA Cable m, 3 x.75mm² Functional data orque (nominal torque) Min. nominal voltage Direction of rotation Reversible with switch resp. adjustable mechanical end stops Running time 5s / 9 Safety Protection class II otally insulated Low voltage directive CE according to 24/8/EC CE according to 26/95/EC Certification Certified to IEC/EN 673- and IEC/EN Mode of operation ype 2.5kV Ambient temperature range C Non-operating temperature C -free Dimensions / Dimensions See «Dimensions» Approx..kg ) ) 2 ) CrNi (INOX) V Subject to modification
5 SM23A-S Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services orque 2Nm Nominal voltage AC...24V with integrated auxiliary switch Electrical data Nominal voltage AC...24V, 5/6Hz AC V nominal torque.6w 6VA x SPD, ma...3 (.5) A, AC 25V (...% adjustable) Motor Cable m, 3 x.75mm² Cable m, 3 x.75mm² Functional data orque (nominal torque) Min. nominal voltage Direction of rotation Reversible with switch resp. Running time 5s / 9 Safety Protection class II otally insulated Low voltage directive CE according to 24/8/EC CE according to 26/95/EC Certification culus according to UL 673-A and UL and CAN/CSA E673-:2 Certified to IEC/EN 673- and IEC/EN Mode of operation ype 2.5kV Ambient temperature range C Non-operating temperature C -free Dimensions / Dimensions See «Dimensions» Approx..2kg 39 V Subject to modification Damper spindle ) CrNi (INOX) Length ) )
6 SM23ASR Modulating damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services orque 2Nm Nominal voltage AC...24V Control: Modulating DC ()2...V Position feedback DC 2...V Electrical data Nominal voltage AC...24V, 5/6Hz AC V nominal torque.6w 6.5VA supply Signals Cable m, 2 x.75mm ² Cable m, 4 x.75mm ² Functional data orque (nominal torque) Min. nominal voltage Control Control signal Y Operating range DC ()2...V, typical input impedance kω DC 2...V Position feedback (Measuring voltage U) DC 2...V, max. ma Auxiliary supply DC 24V ±3%, max. ma Position accuracy ±5% Direction of rotation Reversible with switch / Direction of motion at Y = V In switch position resp. Running time 5s / 9 Safety Protection class II otally insulated Low voltage directive CE according to 24/8/EC CE according to 26/95/EC Certification culus according to UL 673-A and UL and CAN/CSA E673-:2 Certified to IEC/EN 673- and IEC/EN Mode of operation ype 2.5kV Ambient temperature range C Non-operating temperature C -free Dimensions / Dimensions See «Dimensions» Approx..kg Damper spindle Length ) ) 2 ) CrNi (INOX) V Subject to modification
7 Wiring diagrams-general Damper Actuator Wiring diagrams: Open/Close actuators parallel connection possible, please note the performance data -wire control AC 24V + DC 24V! via safety isolated transformer (while Direction of rotation direction of rotation reverses) 2-wire control AC 24V + DC 24V! (while via safety isolated transformer Direction of rotation direction of rotation reverses) 2 3 S S2 S3 S S2 S3 S S2 S3 2 3 S S2 S3 S S2 S3 S S2 S3...% LM24A-S, LMU24-S, NM24A-S NMU24-S SM24A-S SMU24-S...% LM24A-S, LMU24-S, NM24A-S NMU24-S SM24A-S SMU24-S LM24A(-P/-F), LMU24(-/-F), NM24A(-P), NMU24(-), SMU24 SM24A GM24A, GMU24, LMQ24A, LMQU24, NMQ24A, NMQU24, SMQ24A SMQU24 LM24A(-P/-F), LMU24(-/-F), NM24A(-P) NMU24(-) SM24A, SMU24, GM24A* GMU24* N L AC...24V N L AC...24V 2 3 S S2 S3 S S2 S3 S S2 S3 2 3 S S2 S3 S S2 S3 S S2 S3...% LM23A-S, LMU23-S, NM23A-S, NMU23-S SM23A-S SMU23-S...% LMU23-S, NMU23-S NM23A-S, SM23A-S SMU23-S LM23A(-P/-F), LMU23(-F), NMU23 NM23A(-P) SM23A, SMU23(-F), SMD23A, SMDU23, GM23A GMU23 LM23A(-F), LMU23(-F), NM23A, NMU23(-F) NMD23A SM23A, SMU23(-F), SMD23A, SMDU23, GM23A* GMU23* *GMU.. *GM..A.. only only for for Open/Close Open/Close application. application. Wiring diagrams: Modulating actuators parallel connection possible, please note the performance data Position - signal voltage + AC 24V DC 24V! Y via safety isolated transformer DC ()2...V % of 95 Reversing switch Y = Reversing switch Y = U DC 2...V Open Open Closed Closed + Y U LM(Q)24A-SR, LM(Q)U24-SR, NM(Q)24A-SR, NM(Q)U24-SR SM(Q)24A-SR, SM(Q)U24-SR, GM24A-SR GMU24-SR Y 2 5 [ V ] anti-clockwise -closing damper clockwiseclosing damper N L AC...24V AC 24V power output Y U DC ()2...V DC 2...V Direction of rotation V Subject to modification Y U LM23ASR, LMU23SR, NM23ASR NMU23SR SM23ASR SMU23SR 87
In operation At rest For wire sizing
NMQ24A Damper actuator for adjusting air control dampers in ventilation and air-conditioning systems for building services installations orque 8Nm Nominal voltage AC/DC 24V Control: Open-close (not made
More informationTechnical data. Safety notes
echnical data sheet SM4A-S-P Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque Nm Nominal
More informationNominal voltage Nominal voltage range Power consumption Wire / tranformer sizing. Connection: Motor LMU24(-S/-F) Cable 1m, 3x0.
LMU24(S/F/) For operation of air control dampers in HVAC system orque: 5Nm Nominal voltage: AC/DC 24V Control: Open/Close or 3point echnical data Electrical data Functional data Working conditions Nominal
More informationNon-Spring Return SMU... series
Non-Spring Return SMU... series Product overview New Generation Non-spring return actuator Open/Close, 3-point AC 24 V 5/6 Hz, DC 24 V Auxiliary switch build-in SPD AC..24 V 5/6 Hz AC 23 V 5 Hz (Open/Close)
More informationTechnical data. Safety notes
echnical data sheet SMA-S-P Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque m ominal voltage
More informationPower consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive
Technical data sheet NFU Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations Torque: 10Nm Nominal voltage: AC 4... 40V DC 4...15V
More informationTechnical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch
echnical data sheet Damper actuator NM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up
More informationTechnical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch
echnical data sheet Damper actuator LM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up
More informationElectrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz
GR24A-5 / -7 GR24A-5 Rotary actuator for rotary valves GR24A-7 Rotary actuator for rotary valves Nominal torque 40Nm Nominal voltage AC/DC 24V Control Open-close echnical data Electrical data Nominal voltage
More informationElectrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V
echnical data sheet SH24A-SR.. Modulating linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m 2 Actuating
More informationPower consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3
SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage
More informationPower consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch
echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx 4 m 2 orque 20 m ominal voltage AC/DC
More informationElectrical data Nominal voltage AC 230 V Nominal voltage frequency
echnical data sheet NRA Rotary actuator for ball valves Nominal torque Nm Nominal voltage AC V Control Open-close, -point echnical data Electrical data Nominal voltage AC V Nominal voltage frequency 5/6
More informationPower consumption In operation At rest For wire sizing
echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage AC/DC
More information2. A E LM Form-fit versions Linear adapter ZH-LM
Actuators for heating, ventilation, air-conditioning 2. A1-90122 - E LM Form-fit versions Linear adapter ZH-LM OEM at001707 at00205 Linear adapter ZH-LM: For LM2... damper actuators with universal spindle
More informationPower consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return
echnical data sheet FA-S2 actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage
More informationPower consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch
echnical data sheet SF24G-S-S2- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building
More informationOverview of types. Technical data. Safety notes
echnical data sheet LH4A-S-P.. Linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air dampers up to approx.
More informationPower consumption In operation At rest For wire sizing
echnical data sheet SF24G-S- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building
More informationPower consumption In operation At rest For wire sizing
echnical data sheet FA actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage
More informationPower consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor
Technical data sheet GK24G- SuperCap rotary actuator with emergency setting function and extended functionalities in the IP66 protective housing for adjusting air dampers in ventilation and air-conditioning
More informationActuators for heating, ventilation, air-conditioning 2. LM-4 -CD. Product Information Damper actuators. i
Actuators for heating, ventilation, air-conditioning. LM-4 -CD Product Information Damper actuators LM i689 he complete range of damper actuators for general use in HVAC systems ype LM NM SM AM GM LF AF
More informationCharacterised Control Valves with Actuators
Characterised Control Valves with Actuators echnical Databook Version 6.2 Belimo Asia Pacific Product Overview and able of Contents able of Contents 2 Control Valves and Actuators Product Overview 3 Characterised
More informationSee «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool
echnical data sheet LHA-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control
More informationPower consumption In operation At rest For wire sizing
echnical data sheet SFG- Spring return actuator with emergency function in the IP66 I protective protecti e housing for adjusting air dampers in industrial plants and in technical building installations
More informationPower consumption In operation At rest For wire sizing. Non-operating temperature
echnical data sheet DRC4G--7 Rotary actuator for butterfly valves for outdoor applications orque 90 Nm (not constant) Nominal voltage AC/DC 4 V Control: Open-close IP66 Optimum protection against moisture
More informationPower consumption In operation At rest For wire sizing
echnical data sheet LHK24A-SZ Modulating SuperCap linear actuator with emergency setting function and extended functionalities for adjusting air dampers and sliders in ventilation and air-conditioning
More informationAttachments. Open/Close actuators. For the opening and closing of dampers in air conditioning. 06/2017 DE/en PD OC 1
X X testregistrierung Attachments For the opening and closing of dampers in air conditioning systems Actuators for Type JZ, JZ-AL, JZ-LL, JZ-LL-AL, JZ-HL, JZ-HL-AL multileaf dampers Change of the damper
More informationPower consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor
echnical data sheet SHK24A Linear actuator with capacitor technology for adjusting air dampers and sliders with emergency control function and extended functionalities in ventilation and air-conditioning
More informationMinimum 18 in-lb Torque
CM Series Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM CMB Series - At A Glance CMB24-3 (p. 311) CMB24-3-T (p. 311) CMB120-3 (p. 313) CMB24-SR-R
More informationSee «Overview of types»
echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m Actuating
More informationPower consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point
Actuators Technical data sheet Continuous control of spring return actuator Description Spring-return actuator for adjusting and regulating dampers and valves in air conditioning and ventilation. Torque
More informationFire and Smoke Damper Actuator product overview
Fire and Smoke Damper Actuator product overview Fire and Smoke protection Spring-Return Actuator BLF.. BF.. BFG.. FSLF..US FSNF..US FSAF..US Agency listing CE certification UL555 and UL555S Torque - Motor
More informationPower consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point
Actuators Technical data sheet Continuous control of rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in ventilation and air conditioning
More informationElectrical data Nominal voltage AC V / DC V Nominal voltage frequency
Technical data sheet NFG-S2-L Spring-return actuator with emergency control function for adjusting dampers in technical building installations Air damper size up to approx. 2 m² Nominal torque 10 Nm Nominal
More informationSpring-Return Damper Actuator NF24(-S)
Spring-eturn Damper Actuator NF24(-S) For operation of air control dampers that perform safety function Torque: 7Nm Nominal voltage: AC/ Control: Open/Close Integrated auxiliary switch NF24-S Technical
More informationGMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC
On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 00 to 40 VAC Torque min. 60 in-lb for control of damper surfaces up to 90 sq ft. Application For on/off and floating point control of dampers
More informationLMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma
LMX0-SR Proportional Control, Non-Spring Return, Direct Coupled,00 to 0 VAC, for to 0 VDC and to 0 ma Torque min. 5 in-lb for control of damper surfaces up to sq ft. Application For proportional modulation
More informationElectrical data Nominal voltage AC 24 V Nominal voltage frequency
Technical data sheet Globe valve actuator with emergency control function for 2-way and 3-way globe valves Actuating force N Nominal voltage AC 24 V Control 3-point Nominal stroke 2 mm Design life SuperCaps:
More informationVersatile and Powerful
AM Series Direct Coupled Actuator Versatile and Powerful Minimum 180 in-lb torque in a compact package. For damper areas up to 45 sq-ft* All Actuators have BDCM AM Series - At A Glance AMB(X)24-3 (p. 148)
More informationP2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends
P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends Application Water-side control of heating and cooling systems for AHUs and water coils. Equal Percentage/
More informationTechnical data sheet. Technical data. Safety notes
echnical data sheet NM24P Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..6 m 2 orque 8 Nm Nominal voltage
More informationNMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology
NMQB-MFT, NMQX-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Application For proportional modulation of dampers in HVAC systems. Actuator sizing should
More informationLMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V
LMB- (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 5 in-lb for control of damper surfaces up to sq ft. Technical Data LMB- on/off-floating Power Supply VAC ±
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
Technical data sheet DRK24A-5 SuperCap rotary actuator with emergeny control function and extended functionalities for butterfly valves Nominal torque 9 Nominal voltage AC/DC 24 V Control Open-close Design
More informationGMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma
Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For proportional modulation of dampers
More informationZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators
ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators The ZG-JSL jackshaft linkage is designed to easily attach to any part of a jackshaft and allow easy installation
More informationActuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return.
Actuators for heating, ventilation, air conditioning 2. F-2 -CD Product Information Damper actuators with spring return F i6772 Contents Selection table orque 4 Nm F24 F24-S F23 F23-S F24-3 F24-S Nominal
More informationLMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.
LMCB4-SR (-T) Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMCB4-SR LMCB4-SR-T HALOMO Brushless
More informationPower consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point
Actuators Technical data sheet Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor
More informationNMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology
NMB (X) -MFT Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Torque min. 90 in-lb for control of damper surfaces up to sq ft. Technical Data NMB(X)-MFT Power Supply
More informationAMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V
AMB-(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 80 in-lb for control of damper surfaces up to 5 sq ft. Application For on/off and floating point control of dampers
More informationMinimum 27 in-lb Torque
LU Series Actuator Minimum 27 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM LU Series - At A Glance LUB(X)24-3 (p. 351) LUX120-3 (p. 353) LUB(X)24-SR (p. 355) LUX120-SR (p.
More informationNFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V
NFB4, NFB4-S, NFX4, NFX4-S On/Off, Spring Return, 4 V Torque min. 90 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection NFB4... NFX4...
More informationPower consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40...
echnical data sheet SM24P-S Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..2 m 2 orque 8 Nm Nominal
More informationMinimum 27 in-lb torque
LU Series Actuator Minimum 27 in-lb torque For damper areas up to 6.8 sq-ft* All Actuators have BDCM LU Series - At A Glance LUB(X)24-3 (p. 258) LUB(X)24-SR (p. 260) LUX24-MFT (p. 262) Basic Product Flexible
More informationElectrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing
echnical data sheet LH4A.. Linear actuators for operating air control dampers and slide valves in ventilation and air-conditioning systems For air control dampers up to approx. m Actuating force 5 ominal
More informationMount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)
EFB and EFX Series Spring Return Direct Coupled Actuator Minimum 70 in-lb Torque For damper areas up to 66 sq-ft* (For lower torque, see AFB, AF, NFB, LF, or TF series) Applications New standard clamp
More informationVersatile and Powerful
LM Series Direct Coupled Actuator Versatile and Powerful Minimum 45 in-lb torque in a compact package. For damper areas up to 11 sq-ft* Actuators in bold have BDCM LM Series - At A Glance LMB(X)24-3(-S)(-T)
More informationAMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V
AMB4-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 80 in-lb for control of damper surfaces up to 45 sq ft. Application For on/off and floating point control of
More informationProduct Cross Reference
AF120 US, AF120-S US AF230 US, AF230-S US AFBUP, AFBUP-S, AFXUP, AFXUP-S Torque 133 in-lb [15 Nm] minimum 180 in-lb. [20 Nm] minimum OPERATION Running Time Noise Level < 75 seconds
More informationDamper Actuators Non-Spring Return
50 Non-Spring Return MD5A, MD10A, MD20A, MD40A The MD.A series are 2-10V modulating damper actuators designed for operating air control dampers in ventilation and air conditioning systems for building
More informationPower consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point
Actuators Technical data sheet Rotary drive Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor Nominal Voltage Control Damper size Damper
More informationButterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific
Butterfly Valves Technical Databook Version 7.2 Belimo Asia Pacific BFV and Actuators Product Range Overview and Applications BU6..Series Motorised Butterfly Valves page 4 BU6..Series Butterfly Valves
More informationPower consumption In operation At rest For wire sizing
echnical data sheet SHA.. inear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. m Actuating force 45 ominal voltage
More informationMinimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.
TF Series Spring Return Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 4.5 sq-ft* Applications Cost effective quality and performance for a range of applications including: Classroom
More informationMounting Installation Instructions LM, NM, AM, GM
709-0000 Rev G Mounting Installation Instructions LM, NM, AM, GM General Information Preliminary steps. Belimo actuators with NEMA or NEMA ratings should be mounted indoors in a dry, relatively clean environment
More informationDA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators
Datasheet 53lb-in (6 Nm), Non-Spring Return Damper Actuators Overview The direct-coupled fail-safe/failin-place electronic actuators are designed for modulating, two position, and floating control of laboratory
More informationMF /MS Series
MF41-6153/MS41-6153 Series 24 Vac, Three-position/Modulating Non-spring Return Rotary Electronic Damper SmartX Actuators General Instructions Description The direct-coupled, 24 Vac, non-spring return electronic
More informationType 231 ACTUATOR FOR DAMPERS. G R U N E R t h e. f r i e n d l y a l t e r n a t i v e. Actuator with rotation drive. 20 Nm 30 Nm
ACTUATOR FOR DAMPERS Type 231 Actuator with rotation drive 2 Nm Nm For the application with Room ventilation techniques VAV Valves Page: Content: 2 3 4-9 1-16 17 18-19 2 General overview Summary 231, 2
More informationElectrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature
echnical data sheet SR24P-R Robustline rotary actuator for butterfly valves and rotary valves in Retrofit applications orque 18 Nm Nominal voltage AC/DC 24 V Control: Open-close or 3-point Optimum protection
More informationDamper actuators with spring return
Damper s with spring return 4 Nm 4 Nm damper with spring return 8...16 mm Ø (round shaft), 8...12 mm (square shaft) Max. damper size 0.8 m 2 4 Nm 20 s, -20...+50 C, max. 60 s at -30 C Article Control signal
More informationVA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators
VA-640GSX024P Datasheet Large Globe Actuators Overview The VA-640GSX024P Electronic valve actuators receive a 0 to 10 VDC or 4 to 20 ma control signal to proportionally control the valve. Applications
More informationProduct Table of overview contents and table of contents. Table of contents
Product able of overview contents and table of contents able of contents Product overview he Belimo characterized control valves (CCV) he Belimo characterized control valves (CCV), notes he sizing of ball
More informationMinimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator
NFB and NFX Series Spring Return Direct Coupled Actuator Minimum 90 in-lb Torque For damper areas up to sq-ft* Applications 1 3/4 1/ New standard clamp fits standard 1/ shafts to 1.05 jackshafts. Mount
More informationOutput signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W
Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges and outputs 0 to 5/10 V or 4 to 20 ma. NEMA 4X / IP65 rated enclosure. For monitoring the differential pressure
More informationDuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating
General Instructions DuraDrive MF4-653/MS4-653 Series Non-spring Return Rotary Electronic Damper Actuators 4 Vac Three-position/Modulating Description The DuraDrive direct-coupled, 4 Vac, non-spring return
More informationCharacterised Control Valves with Actuators
Characterised Control Valves with Actuators Technical Databook Version 8.6 Belimo Asia Pacific Contents Control Valves and Actuators Product Overview 4 Characterised Control Valve 6 Sizing of Ball Valves
More informationBELIMO CONTROLS
INDEX ACCESSORIES MECHANICAL CRANK ARM ADAPTOR KITS... 7-17 JACKSHAFT LINKAGE FOR SPRING RETURN DAMPER ACTUATORS... 7-17 MISCELLANEOUS... 7-17 MOUNTING BRACKETS... 7-17 DAMPER ACTUATORS FIRE AND SMOKE
More informationElectro Controls. Damper Actuators / Valve Motors WattsIndustries.co.uk
Electro Controls Damper Actuators / Valve Motors - 2017 WattsIndustries.co.uk Damper Actuators / Valve Motors Section 21 DAMPER / VALVE MOTORS 4Nm 2 & 3 POINT EK4.. These small motors can be fitted directly
More informationGlobe Valves. Technical Databook Version 1.2. Belimo Asia Pacific
Globe Valves Technical Databook Version 1.2 Belimo Asia Pacific Contents Globe Valves Product Overview Max. Close-off Pressure - Globe Valve Series Globe Valve Actuators Product Overview 4 5 General Information
More informationM9208-xxx-x Series Electric Spring Return Actuators
Code No. LIT-1900562 Issued March 10, 2009 M9208-GGx-x, M9208-AGx-x, M9208-Bxx-3 M9208-xxx-x Series Electric Actuators Description The M9208-xxx-x Series Electric Spring Return Actuators provide control
More informationCurrent consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time
Technical data sheet Rotary actuator SY-4--T Rotary actuators for butterfly valves Torque 50 Nm Nominal voltage AC 4 V Control: Open-close or -point Auxiliary switch Technical data Electrical data Nominal
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More informationMechanical Fail-Safe Damper Actuator NFA
2-FON echnicl Fil-Sfe Dmper Actutor NFA ctutor emergency function for djusting ir dmpers in ventiltion nd ir conditioning systems in uildings orque Nm Nominl voltge AC 24..4V / DC 24..V Control: Open-close
More informationFSAF24(-S) US, FSAF120(-S) US
FSAF4(-S) US, FSAF10(-S) US On/Off, Spring Return, Meets 50 F [11 C] for Half Hour, 75 Seconds Torque min. 133 in-lb, for control of air dampers Technical Data FSAF4(-S) US, FSAF10(-S) US Power supply
More informationVolume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper
Volume Control Dampers Incorporating Series HVC-VCD Excellent general purpose volume control damper Lightweight aluminium construction Fully protected linkage system positioned outside of airstream Very
More informationBelimo is the Worldwide Leader in Fire and Smoke Actuation
FS Series Fire and Smoke Direct Coupled Actuators Belimo is the Worldwide Leader in Fire and Smoke Actuation Gateway Base II, Hong Kong Belimo first produced actuators for the European fire and smoke damper
More informationLF Series Spring Return Direct Coupled Actuator
LF Series Spring Return Direct Coupled Actuator Minimum in-lb torque LF actuator For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including:
More informationPower consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω
Actuators Technical data sheet Rotary actuator for control of volumetric flow without spring return Description Actuator for Volumetric flow and pressure control. Torque Motor Nominal Voltage Control Pressure
More informationTechnical data. Safety notes
echnical data sheet MP-S Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx 6 m orque 8 m ominal voltage
More informationLMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V
LMX4- (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMX4- LMX4--T Application For on-off and floating point
More informationM9208-xxx-x Series Electric Spring Return Actuators
Code No. LIT-1900562 Issued February 1, 2013 M9208-GGx-x, M9208-AGx-x, M9208-Bxx-3 M9208-xxx-x Series Electric Spring Return Actuators Description The M9208-xxx-x Series Electric Spring Return Actuators
More informationLF Series At A Glance
LF Series Spring Return Direct Coupled Actuator Minimum 35 in-lb Torque For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including: Classroom
More informationVolume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating
Volume Control Dampers Incorporating Series LF upvc-vcd 2.76 m 3 /hr/m 2 leakage at 50 Pa, over 70% better than required by Part L of Building Regulations Corrosion resistant, perfect for chlorinated atmospheres
More informationM9203-xxx-2(Z) Series Electric Spring Return Actuators
M9203-AGx-2(Z), M9203-GGx-2(Z), M9203-Bxx-2(Z) M9203-xxx-2(Z) Series Electric Spring Return Actuators Code No. LIT-1900682 Issued February 16, 2011 Description The M9203-xxx-2(Z) Series Electric Spring
More informationD24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)
Installation Instructions D24-53 Issue Date November 4, 23 D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m) Installation IMPORTANT: The D24-53 Series actuator is intended to control
More informationButterfly Valves. Technical Databook. Belimo Asia Pacific
Butterfly Valves Technical Databook Version 6 Belimo Asia Pacific Index BFV and Actuators Product Range Overview and Applications BU6..Series Motorised Butterfly Valves BU6..Series Butterfly Valves General
More informationTechnical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators
OpenAir GQD Series Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators Technical Instructions Document No. 155-760 EA GQD Description Features Application The OpenAir GQD Series direct-coupled
More informationM9203-xxx-2(Z) Series Electric Spring-Return Actuators
Code No. LIT-1900682 Issued January 2, 2014 M9203-xxx-2(Z) Series Electric Spring-Return Actuators Description The M9203-xxx-2(Z) Series Electric Spring-Return Actuators provide control of dampers in HVAC
More information