See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Size: px
Start display at page:

Download "See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool"

Transcription

1 echnical data sheet LHA-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control dampers up to approx. m Actuating force N Nominal voltage AC/DC V Control: modulating DC... V or variable Position feedback DC... V or variable Lenght of stroke 6,, or mm Overview of types ype Stroke (adjustable in steps of mm) Operating range Weight LHA-MF6 p to max. 6 mm DC... V... 6 mm g LHA-MF p to max. mm DC... V... mm g LHA-MF p to max. mm DC... V... mm g LHA-MF p to max. mm DC... V... mm 7 g echnical data Electrical data Nominal voltage AC V, /6 Hz / DC V Nominal voltage range AC V / DC V Power consumption In operation nominal force At rest. W For wire sizing VA Connection Cable m, x.7 mm Functional data Factory settings Variable Settings Actuating force Min. nominal voltage %, %, 7% reduced... Control Control signal DC... V, input impedance k Open-close, -point (AC only), modulating (DC... V)... Operating range DC... V Start point DC.... V (See also «Overview of types») End point DC.... V... Position feedback (Measuring voltage ) DC... V, max., ma Start point DC V End point DC.... V... Position accuracy ±% Stroke See «Overview of types» Direction of stroke at = V Reversible with switch resp. Electronically reversible... Manual override Gearing latch disengaged with pushbutton, can be locked Stroke adjustment Max. 6,, or mm, adjustable in steps of mm, can be limited at both ends with mechanical adjustable end stops Running time LHA-MF6 LHA-MF// Automatic adjustment of the operating range and the measuring signal to match the mechanical stroke adjustment Override control 9 s / 6 mm s / mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-ool MAX (maximum position) = % MIN (minimum position) = % ZS (intermediate position, AC only) = % Sound power level Max. db (A) With a running time Safety Protection class Degree of protection EMC III Safety extra-low voltage / L Class Supply IP in any mounting position NEMA, L Enclosure ype CE according to /8/EC... 6 s / 6 mm s / mm Automatic adaption whenever the supply voltage is switched on, or manual triggering... MAX = (MIN %)... % MIN = %... (MAX %) ZS = MIN... MAX... 7 s = db (A) 7 s = db (A) LHA-MF.. en v. 8.9 Subject to changes / 6

2 LHA-MF.. Multifunctional linear actuators, AC/DC V, N echnical data (Continued) Safety Certification clus according to L 67-A and L 67-- and CAN/CSA E67-: Certified to IEC/EN 67- and IEC/EN 67-- Mode of operation ype Rated impulse voltage.8 kv Control pollution degree Ambient temperature... C Non-operating temperature... 8 C Ambient humidity 9% r.h., non-condensating Maintenance Maintenance-free Dimensions / Weight Dimensions See «Dimensions» on page Weight See «Overview of types» on page. Safety notes! he actuator is not allowed to be used outside the specified field of application, especially not in aircraft or any other form of air transport. Assembly must be carried out by trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. he cable must nut be removed from the device. he rotary supports and coupling pieces available as accessories must always be used if lateral forces are likely. In addition, the actuator must not be tightly bolted to the application. It must remain movable via the rotary support (refer to «Assembly notes»). If the linear actuator is exposed to severely contaminated atmosphere, appropriate precautions must be taken on the system side. Excessive deposits of dust, soot etc. can prevent the gear rack from being extended and retracted correctly. If not installed horizontally, the gear disengagement pushbutton may only be actuated when there is no pressure on the gear rod When calculating the required actuating force, the specifications supplied by the damper or slide valve manufacturers (cross section, design, installation site), and the air flow conditions must be observed. If a rotary support and/or coupling piece is used, losses in the actuation force are to be expected. he device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. Product features Mode of operation Parameterisable actuators Simple direct mounting Manual override Stroke adjustment High functional reliability he actuator is controlled with a standard modulating signal of DC... V and travels to the position defined by the control signal. Measuring voltage serves for the electrical display of the damper position... % and as slave control signal for other actuators. he factory settings cover the most common applications. Input and output signals and other parameters can be altered with the MF-H parameterising device or the BELIMO Service ool, MF-P. he actuator can be directly connected with the application using the enclosed screws. he head of the gear rod is connected to the moving part of the ventilation application individually on the mounting side or with the Z-KS coupling piece provided. Manual operation is possible with the pushbutton (the gearing latch remains disengaged as long as the pushbutton is pressed or detented). he stroke of the gear rack can be adjusted on both sides in increments of mm by means of mechanical end stops. he actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. / 6 -LHA-MF.. en v. 8.9 Subject to changes

3 LHA-MF.. Multifunctional linear actuators, AC/DC V, N Product features Accessories Home position (Continued) When the supply voltage is switched on for the first time, i.e. at commissioning or after pressing the «gear disengagement» switch, the actuator travels to the home position. Pos. direction of stroke switch = = Home position extended retracted he actuator then moves into the position defined by the control signal. Description Data sheet Electrical accessories Parameterising device MF-H - MF-H PC-ool MF-P - MF-P Position sensor SGA, SGE and SGF - SG.. Digital position indication ZAD - ZAD Mechanical accessories Rotary support to compensate lateral forces Z-DS - Z-LH..A.. Coupling piece Z-KS - Z-LH..A.. Mechanical limiter set Z-AS - Z-LH..A.. Electrical installation Wiring diagram Notes Connection via safety isolating transformer!! Other actuators can be connected in parallel. Please note the performance data! Control signal Measuring voltage Cable colours: = black = red = white = orange Assembly notes Application without lateral forces Application with lateral forces Caution If a rotary support and/or coupling piece is used, losses in the actuation force are to be expected.! he linear actuator is screwed directly to the housing at three points. Afterwards, the head of the gear rod is fastened to the moving part of the ventilation application (e.g. damper or slide valve). he coupling piece with the internal thread (Z-KS) is connected to the head of the gear rod. he rotary support (Z-DS) is screwed to the ventilation application. Afterwards, the linear actuator is screwed to the previously mounted rotary support with the enclosed screw. Afterwards, the coupling piece, which is mounted to the head of the gear rod, is attached to the moving part of the ventilation application (e.g. damper or slide valve). he transverse forces can be compensated for to a certain limit with the rotary support and/or coupling piece. he maximum permissible swivel angle of the rotary support and coupling piece is, laterally and upwards. -LHA-MF.. en v. 8.9 Subject to changes / 6

4 LHA-MF.. Multifunctional linear actuators, AC/DC V, N Functions with basic values Override control with AC V with relay contacts a b c z.b. N 7 (DC... V) From controller Functions a b c % Override control with AC V with rotary control switch (DC... V) From controller z.b. N 7 Pos % Functions ZS % (intermediate position) ZS % (intermediate position) % % Control mode in accordance with Control mode in accordance with Remote control... % Minimum limit Z SGA SGF SGE Position sensor Z SGA SGF SGE Position sensor [V] (DC... V) From controller min [%] Master/Slave control (position-dependent) Control with... ma via external resistance DC... V Ω () ()... ma DC... V o the following actuator DC... V Master actuator Slave actuator he resistor converts the... ma current signal to a voltage signal DC... V Position indication Functional check Adapting the direction of rotation ZAD Procedure Apply V to connection and Disconnect connection : For direction of stroke : Actuator travels in the direction of For direction of stroke : Actuator travels in the direction of Short circuit connections and : Actuator travels in the opposite direction / 6 -LHA-MF.. en v. 8.9 Subject to changes

5 LHA-MF.. Multifunctional linear actuators, AC/DC V, N Functions for actuators with specific parameters Override control and limiting with AC V with relay contacts a b c d e (DC... V) From controller Functions a b c d e CLOSE ) Override control and limiting with AC V with rotary switch Z ) MIN ZS MAX AF (DC... V) From controller z.b. N 7 z.b. N 7 MIN ZS (intermediate position) MAX OPEN Control mode in accordance with ) Caution! his function is only guaranteed if the start point of the operating range is defined as min..6 V -point control Open-close control a b z.b. N 7 Direction of stroke switch a b stop stop Dimensions [mm] Dimensional drawings B ype Max. stroke A B LHA-MF LHA-MF. 6. LHA-MF. 6. LHA-MF. 6. A LHA-MF.. en v. 8.9 Subject to changes / 6

6 LHA-MF.. Multifunctional linear actuators, AC/DC V, N Operating controls and indicators Direction of stroke switch Switching over: Direction of stroke changes Pushbutton and green LED display Off: No voltage supply or malfunction On: Operation Press button: Switches on stoke adaption followed by standard operation Pushbutton and yellow LED display Off: Standard operation On: Adaption or synchronising process active Press button: No function Gear disengagement switch Press button: Gear disengaged, motor stops, manual operation possible Release button: Gear engaged, synchronisation starts, followed by standard operation Service plug For connecting parameterising and service tools Check voltage supply connection a) Off and On Check the supply connections. Possibly and are swapped over. b) Blinking and Blinking. 6 / 6 -LHA-MF.. en v. 8.9 Subject to changes

7 LH..A C LH..A. / LHA-SX.. / LHA-MF.. / LHA-MP.. / LHV-D-MP... A x Ø max. 8mm mm mm B Z-KS M6 Z-KS ± Z-KS M6 mm Z-DS Z-DS. Z-DS. M-LH..A.. v. 7.9 /

8 LH..A.. LHA-SR. / LHASR.. A x Ø max. 8mm B Z-KS M6 Z-KS ± Z-KS M6 Z-DS Z-DS.. / M-LH..A.. v

9 LH..A.. LH..A.. / LHA-SR. / LHA-SX.. / LHA-MF.. / LHA-MP.. / LHV-D-MP.. / LHASR.. N L N L N L AC V / DC V S S S...% LHA.. LHA-S.. AC... V! N L L N L L S S S S S S S S S LHA.. LHA-S.....% AC V / DC V DC V DC V DC V MP LHA-SR.. LHA-SX.. LHA-MF.. LHA-MP.. LHV-D-MP.. AC V N L SG.. DC... V DC... V LHASR.. M-LH..A.. v. 7.9 /

10 LH..A.. LH..A..P Z-P 6 mm mm...6 mm ype mm ype mm ype - 6 max Nm / M-LH..A.. v

See «Overview of types»

See «Overview of types» echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m Actuating

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V echnical data sheet SH24A-SR.. Modulating linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m 2 Actuating

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing echnical data sheet LH4A.. Linear actuators for operating air control dampers and slide valves in ventilation and air-conditioning systems For air control dampers up to approx. m Actuating force 5 ominal

More information

Overview of types. Technical data. Safety notes

Overview of types. Technical data. Safety notes echnical data sheet LH4A-S-P.. Linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air dampers up to approx.

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SHA.. inear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. m Actuating force 45 ominal voltage

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet LHK24A-SZ Modulating SuperCap linear actuator with emergency setting function and extended functionalities for adjusting air dampers and sliders in ventilation and air-conditioning

More information

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor echnical data sheet SHK24A Linear actuator with capacitor technology for adjusting air dampers and sliders with emergency control function and extended functionalities in ventilation and air-conditioning

More information

Technical data. Safety notes

Technical data. Safety notes echnical data sheet SM4A-S-P Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque Nm Nominal

More information

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch echnical data sheet Damper actuator NM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up

More information

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch echnical data sheet Damper actuator LM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SF24G-S- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building

More information

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz GR24A-5 / -7 GR24A-5 Rotary actuator for rotary valves GR24A-7 Rotary actuator for rotary valves Nominal torque 40Nm Nominal voltage AC/DC 24V Control Open-close echnical data Electrical data Nominal voltage

More information

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch echnical data sheet SF24G-S-S2- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building

More information

Technical data. Safety notes

Technical data. Safety notes echnical data sheet SMA-S-P Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque m ominal voltage

More information

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency echnical data sheet NRA Rotary actuator for ball valves Nominal torque Nm Nominal voltage AC V Control Open-close, -point echnical data Electrical data Nominal voltage AC V Nominal voltage frequency 5/6

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage AC/DC

More information

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx 4 m 2 orque 20 m ominal voltage AC/DC

More information

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive Technical data sheet NFU Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations Torque: 10Nm Nominal voltage: AC 4... 40V DC 4...15V

More information

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3 SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SFG- Spring return actuator with emergency function in the IP66 I protective protecti e housing for adjusting air dampers in industrial plants and in technical building installations

More information

Power consumption In operation At rest For wire sizing. Non-operating temperature

Power consumption In operation At rest For wire sizing. Non-operating temperature echnical data sheet DRC4G--7 Rotary actuator for butterfly valves for outdoor applications orque 90 Nm (not constant) Nominal voltage AC/DC 4 V Control: Open-close IP66 Optimum protection against moisture

More information

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor Technical data sheet GK24G- SuperCap rotary actuator with emergency setting function and extended functionalities in the IP66 protective housing for adjusting air dampers in ventilation and air-conditioning

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet FA actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage

More information

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return echnical data sheet FA-S2 actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage

More information

Technical data sheet. Technical data. Safety notes

Technical data sheet. Technical data. Safety notes echnical data sheet NM24P Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..6 m 2 orque 8 Nm Nominal voltage

More information

Power consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40...

Power consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40... echnical data sheet SM24P-S Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..2 m 2 orque 8 Nm Nominal

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature echnical data sheet SR24P-R Robustline rotary actuator for butterfly valves and rotary valves in Retrofit applications orque 18 Nm Nominal voltage AC/DC 24 V Control: Open-close or 3-point Optimum protection

More information

Non-Spring Return SMU... series

Non-Spring Return SMU... series Non-Spring Return SMU... series Product overview New Generation Non-spring return actuator Open/Close, 3-point AC 24 V 5/6 Hz, DC 24 V Auxiliary switch build-in SPD AC..24 V 5/6 Hz AC 23 V 5 Hz (Open/Close)

More information

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency Technical data sheet NFG-S2-L Spring-return actuator with emergency control function for adjusting dampers in technical building installations Air damper size up to approx. 2 m² Nominal torque 10 Nm Nominal

More information

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in ventilation and air conditioning

More information

Technical data. Safety notes

Technical data. Safety notes echnical data sheet MP-S Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx 6 m orque 8 m ominal voltage

More information

Minimum 18 in-lb Torque

Minimum 18 in-lb Torque CM Series Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM CMB Series - At A Glance CMB24-3 (p. 311) CMB24-3-T (p. 311) CMB120-3 (p. 313) CMB24-SR-R

More information

Overview of types. Technical data

Overview of types. Technical data Technical data sheet 6..S+NVFT24-MFT-E Globe valves, 2-way, with flange PN 16, actuator with emergency control function for closed hot water systems up to 150 C in district heating applications approved

More information

In operation At rest For wire sizing

In operation At rest For wire sizing NMQ24A Damper actuator for adjusting air control dampers in ventilation and air-conditioning systems for building services installations orque 8Nm Nominal voltage AC/DC 24V Control: Open-close (not made

More information

Actuators for heating, ventilation, air-conditioning 2. LM-4 -CD. Product Information Damper actuators. i

Actuators for heating, ventilation, air-conditioning 2. LM-4 -CD. Product Information Damper actuators. i Actuators for heating, ventilation, air-conditioning. LM-4 -CD Product Information Damper actuators LM i689 he complete range of damper actuators for general use in HVAC systems ype LM NM SM AM GM LF AF

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency Technical data sheet DRK24A-5 SuperCap rotary actuator with emergeny control function and extended functionalities for butterfly valves Nominal torque 9 Nominal voltage AC/DC 24 V Control Open-close Design

More information

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific Globe Valves Technical Databook Version 1.2 Belimo Asia Pacific Contents Globe Valves Product Overview Max. Close-off Pressure - Globe Valve Series Globe Valve Actuators Product Overview 4 5 General Information

More information

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC 24 V Nominal voltage frequency Technical data sheet Globe valve actuator with emergency control function for 2-way and 3-way globe valves Actuating force N Nominal voltage AC 24 V Control 3-point Nominal stroke 2 mm Design life SuperCaps:

More information

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point Actuators Technical data sheet Rotary drive Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor Nominal Voltage Control Damper size Damper

More information

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor

More information

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time Technical data sheet Rotary actuator SY-4--T Rotary actuators for butterfly valves Torque 50 Nm Nominal voltage AC 4 V Control: Open-close or -point Auxiliary switch Technical data Electrical data Nominal

More information

Minimum 27 in-lb Torque

Minimum 27 in-lb Torque LU Series Actuator Minimum 27 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM LU Series - At A Glance LUB(X)24-3 (p. 351) LUX120-3 (p. 353) LUB(X)24-SR (p. 355) LUX120-SR (p.

More information

Minimum 27 in-lb torque

Minimum 27 in-lb torque LU Series Actuator Minimum 27 in-lb torque For damper areas up to 6.8 sq-ft* All Actuators have BDCM LU Series - At A Glance LUB(X)24-3 (p. 258) LUB(X)24-SR (p. 260) LUX24-MFT (p. 262) Basic Product Flexible

More information

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of spring return actuator Description Spring-return actuator for adjusting and regulating dampers and valves in air conditioning and ventilation. Torque

More information

2. A E LM Form-fit versions Linear adapter ZH-LM

2. A E LM Form-fit versions Linear adapter ZH-LM Actuators for heating, ventilation, air-conditioning 2. A1-90122 - E LM Form-fit versions Linear adapter ZH-LM OEM at001707 at00205 Linear adapter ZH-LM: For LM2... damper actuators with universal spindle

More information

Butterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific

Butterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific Butterfly Valves Technical Databook Version 7.2 Belimo Asia Pacific BFV and Actuators Product Range Overview and Applications BU6..Series Motorised Butterfly Valves page 4 BU6..Series Butterfly Valves

More information

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma LMX0-SR Proportional Control, Non-Spring Return, Direct Coupled,00 to 0 VAC, for to 0 VDC and to 0 ma Torque min. 5 in-lb for control of damper surfaces up to sq ft. Application For proportional modulation

More information

Versatile and Powerful

Versatile and Powerful AM Series Direct Coupled Actuator Versatile and Powerful Minimum 180 in-lb torque in a compact package. For damper areas up to 45 sq-ft* All Actuators have BDCM AM Series - At A Glance AMB(X)24-3 (p. 148)

More information

Nominal voltage Nominal voltage range Power consumption Wire / tranformer sizing. Connection: Motor LMU24(-S/-F) Cable 1m, 3x0.

Nominal voltage Nominal voltage range Power consumption Wire / tranformer sizing. Connection: Motor LMU24(-S/-F) Cable 1m, 3x0. LMU24(S/F/) For operation of air control dampers in HVAC system orque: 5Nm Nominal voltage: AC/DC 24V Control: Open/Close or 3point echnical data Electrical data Functional data Working conditions Nominal

More information

Versatile and Powerful

Versatile and Powerful LM Series Direct Coupled Actuator Versatile and Powerful Minimum 45 in-lb torque in a compact package. For damper areas up to 11 sq-ft* Actuators in bold have BDCM LM Series - At A Glance LMB(X)24-3(-S)(-T)

More information

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return.

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return. Actuators for heating, ventilation, air conditioning 2. F-2 -CD Product Information Damper actuators with spring return F i6772 Contents Selection table orque 4 Nm F24 F24-S F23 F23-S F24-3 F24-S Nominal

More information

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For proportional modulation of dampers

More information

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators The ZG-JSL jackshaft linkage is designed to easily attach to any part of a jackshaft and allow easy installation

More information

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 00 to 40 VAC Torque min. 60 in-lb for control of damper surfaces up to 90 sq ft. Application For on/off and floating point control of dampers

More information

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time Technical data sheet Rotary actuator SY-4--T Rotary actuators for butterfly valves Torque 5 Nm Nominal voltage C 4 V Control: Open-close or -point uxiliary switch Technical data Electrical data Nominal

More information

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1. LMCB4-SR (-T) Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMCB4-SR LMCB4-SR-T HALOMO Brushless

More information

Spring-Return Damper Actuator NF24(-S)

Spring-Return Damper Actuator NF24(-S) Spring-eturn Damper Actuator NF24(-S) For operation of air control dampers that perform safety function Torque: 7Nm Nominal voltage: AC/ Control: Open/Close Integrated auxiliary switch NF24-S Technical

More information

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology NMQB-MFT, NMQX-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Application For proportional modulation of dampers in HVAC systems. Actuator sizing should

More information

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends Application Water-side control of heating and cooling systems for AHUs and water coils. Equal Percentage/

More information

Characterised Control Valves with Actuators

Characterised Control Valves with Actuators Characterised Control Valves with Actuators echnical Databook Version 6.2 Belimo Asia Pacific Product Overview and able of Contents able of Contents 2 Control Valves and Actuators Product Overview 3 Characterised

More information

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology NMB (X) -MFT Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Torque min. 90 in-lb for control of damper surfaces up to sq ft. Technical Data NMB(X)-MFT Power Supply

More information

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency Technical data sheet EV..R+BAC Characterised control valve (CCV) with sensor-operated flow rate or power control, power and energy-monitoring Nominal voltage AC/DC 4 V Control modulating For closed cold

More information

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V NFB4, NFB4-S, NFX4, NFX4-S On/Off, Spring Return, 4 V Torque min. 90 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection NFB4... NFX4...

More information

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω Actuators Technical data sheet Rotary actuator for control of volumetric flow without spring return Description Actuator for Volumetric flow and pressure control. Torque Motor Nominal Voltage Control Pressure

More information

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21) EFB and EFX Series Spring Return Direct Coupled Actuator Minimum 70 in-lb Torque For damper areas up to 66 sq-ft* (For lower torque, see AFB, AF, NFB, LF, or TF series) Applications New standard clamp

More information

Characterised Control Valves with Actuators

Characterised Control Valves with Actuators Characterised Control Valves with Actuators Technical Databook Version 8.6 Belimo Asia Pacific Contents Control Valves and Actuators Product Overview 4 Characterised Control Valve 6 Sizing of Ball Valves

More information

LF Series Spring Return Direct Coupled Actuator

LF Series Spring Return Direct Coupled Actuator LF Series Spring Return Direct Coupled Actuator Minimum in-lb torque LF actuator For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including:

More information

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V LMB- (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 5 in-lb for control of damper surfaces up to sq ft. Technical Data LMB- on/off-floating Power Supply VAC ±

More information

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4. TF Series Spring Return Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 4.5 sq-ft* Applications Cost effective quality and performance for a range of applications including: Classroom

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB-(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 80 in-lb for control of damper surfaces up to 5 sq ft. Application For on/off and floating point control of dampers

More information

PN [ ] D7150NL/BAC D7200WL/BAC D7250WL/BAC D7300WL/BAC [ ]

PN [ ] D7150NL/BAC D7200WL/BAC D7250WL/BAC D7300WL/BAC [ ] Technical data sheet D7../C utterfly valve with actuator, Flange, P 16 Torque motor 160 m ominal voltage C 24...240 V / DC 24...125 V Control Open-close, modulating, communicative for mixing and diverting

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB4-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 80 in-lb for control of damper surfaces up to 45 sq ft. Application For on/off and floating point control of

More information

FSAF24(-S) US, FSAF120(-S) US

FSAF24(-S) US, FSAF120(-S) US FSAF4(-S) US, FSAF10(-S) US On/Off, Spring Return, Meets 50 F [11 C] for Half Hour, 75 Seconds Torque min. 133 in-lb, for control of air dampers Technical Data FSAF4(-S) US, FSAF10(-S) US Power supply

More information

Belimo is the Worldwide Leader in Fire and Smoke Actuation

Belimo is the Worldwide Leader in Fire and Smoke Actuation FS Series Fire and Smoke Direct Coupled Actuators Belimo is the Worldwide Leader in Fire and Smoke Actuation Gateway Base II, Hong Kong Belimo first produced actuators for the European fire and smoke damper

More information

Damper Actuators Non-Spring Return

Damper Actuators Non-Spring Return 50 Non-Spring Return MD5A, MD10A, MD20A, MD40A The MD.A series are 2-10V modulating damper actuators designed for operating air control dampers in ventilation and air conditioning systems for building

More information

SM24A. Technical data. Dimensions [mm]

SM24A. Technical data. Dimensions [mm] SM24A Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services orque 2Nm Nominal voltage AC/DC 24V Electrical data Nominal voltage AC 24V, 5/6Hz / DC

More information

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator NFB and NFX Series Spring Return Direct Coupled Actuator Minimum 90 in-lb Torque For damper areas up to sq-ft* Applications 1 3/4 1/ New standard clamp fits standard 1/ shafts to 1.05 jackshafts. Mount

More information

Product Cross Reference

Product Cross Reference AF120 US, AF120-S US AF230 US, AF230-S US AFBUP, AFBUP-S, AFXUP, AFXUP-S Torque 133 in-lb [15 Nm] minimum 180 in-lb. [20 Nm] minimum OPERATION Running Time Noise Level < 75 seconds

More information

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency Technical data sheet EV..R+KBAC Characterised control valve (CCV) with sensor-operated flow rate or power control, power and energymonitoring function, 2-way, internal thread (Energy Valve), with emergency

More information

Direct Coupled Damper Actuator Model MY9050A1001

Direct Coupled Damper Actuator Model MY9050A1001 AB-4 Specifications/Instructions Direct Coupled Damper Actuator Model MY9050A00 General Model MY9050A00 direct coupled damper actuator is a motorized actuator to open/close a damper. Model MY9050A00 contains

More information

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18) AF Series Spring Return Direct Coupled Actuator Minimum 133 in-lb torque For damper areas up to 35 sq-ft* (For lower torque, see NF, LF, or TF series) Applications Remove for 3/4 to 1.05 shafts ZG106 or

More information

MF /MS Series

MF /MS Series MF41-6153/MS41-6153 Series 24 Vac, Three-position/Modulating Non-spring Return Rotary Electronic Damper SmartX Actuators General Instructions Description The direct-coupled, 24 Vac, non-spring return electronic

More information

LF Series At A Glance

LF Series At A Glance LF Series Spring Return Direct Coupled Actuator Minimum 35 in-lb Torque For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including: Classroom

More information

VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications

VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications 1 2 3 4 5 6 7 8 Technical data sheet 227CS-024-08-V Actuator without spring return for flow- or pressure

More information

Butterfly Valves. Technical Databook. Belimo Asia Pacific

Butterfly Valves. Technical Databook. Belimo Asia Pacific Butterfly Valves Technical Databook Version 6 Belimo Asia Pacific Index BFV and Actuators Product Range Overview and Applications BU6..Series Motorised Butterfly Valves BU6..Series Butterfly Valves General

More information

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges and outputs 0 to 5/10 V or 4 to 20 ma. NEMA 4X / IP65 rated enclosure. For monitoring the differential pressure

More information

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating General Instructions DuraDrive MF4-653/MS4-653 Series Non-spring Return Rotary Electronic Damper Actuators 4 Vac Three-position/Modulating Description The DuraDrive direct-coupled, 4 Vac, non-spring return

More information

AF Series Spring Return Direct Coupled Actuator

AF Series Spring Return Direct Coupled Actuator AF Series Spring Return Direct Coupled Actuator Minimum in-lb torque For damper areas up to sq-ft* (For lower torque, see NF or LF series) Applications Direct Coupling - The Belimo Concept Remove for /

More information

SBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions

SBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions Operating Instructions BKS24-9A Operating Instructions BKS24-9A Table of contents Operating Instructions 1 Operating controls and indicators 2 2 Preparations for faultless commissioning and operating 3

More information

GM Series Direct Coupled Actuator

GM Series Direct Coupled Actuator GM Series Direct Coupled Actuator Minimum 3 in-lb torque** For damper areas up to 8 sq-ft* Applications Linkage is part of inlet vane assembly supplied by manufacturer. Actuator is mounted to vortex frame.

More information

Direct Coupled Damper Actuator Model MY6050A1001

Direct Coupled Damper Actuator Model MY6050A1001 Specifications/Instructions Direct Coupled Damper Actuator General direct coupled damper actuator is a motorized actuator to open/close a damper. Model MY6050A00 provides -position or floating control

More information

Non-Spring Return EconoDrive Floating Actuator

Non-Spring Return EconoDrive Floating Actuator MF4D-0x Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All

More information

[ ] Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

[ ] Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet EP..R+KMP Communicative characterised control valve with sensor-operated flow control and emergency control function, ominal voltage CC 2 V Control Modulating or closed cold and warm

More information

LMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V LMX4- (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMX4- LMX4--T Application For on-off and floating point

More information

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators Datasheet 53lb-in (6 Nm), Non-Spring Return Damper Actuators Overview The direct-coupled fail-safe/failin-place electronic actuators are designed for modulating, two position, and floating control of laboratory

More information

SAX Electronic Valve Actuator

SAX Electronic Valve Actuator SAX Electronic Valve Actuator Non-spring Return, 24 Vac, Proportional Control Technical Instructions Document No. 155-506 Description The SAX Non-spring Return (NSR), Electronic Valve Actuator requires

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100

More information

Air damper actuators

Air damper actuators 4 654 OPEN AIR Air damper actuators Linear version, three-position control, AC 24 V or 230 V GDB..3..2 GLB..3..2 Electric motor-driven linear actuators for three-position control, nominal linear force

More information

Electromotoric actuators

Electromotoric actuators 4 573 SQS35.50, SQS35.53, SQS65.5 with spring return function, without manual adjuster ACVATIX Electromotoric actuators for valves with 5.5 mm stroke SQS35.00, SQS35.03, SQS65, SQS65.2, SQS85.00, SQS85.03

More information

Type overview. R B2 en-gb subject to changes 1

Type overview.  R B2 en-gb subject to changes 1 Technical data sheet R30..-..-..-B2 Characterised control valve, 6-way, Internal thread Two sequences (cooling/heating) with one 90 rotary actuator Switching or modulating control on the water side of

More information