In operation At rest For wire sizing

Size: px
Start display at page:

Download "In operation At rest For wire sizing"

Transcription

1 NMQ24A Damper actuator for adjusting air control dampers in ventilation and air-conditioning systems for building services installations orque 8Nm Nominal voltage AC/DC 24V Control: Open-close (not made for 3-point applications) Running time 4s echnical data Electrical data Nominal voltage, 5/6Hz / DC 24V AC V / DC V nominal torque 2W 23VA (I max. 5ms) Cable m, 3 x.75mm² Functional data orque (nominal torque) Min. nominal voltage Reversible with switch resp. Gearing latch disengaged with pushbutton, can be locked limiting min. 3 Running time 4s / 9 Automatic adjustment of operating range to match the mechanical angle of rotation Manual triggering of the adaption by pressing the «Adaption» button db(a) Negative torque 5% from nominal torque (with restrictions)* Safety Protection class III Safety extra-low voltage, L Class 2 Supply IP54 in any mounting position, NEMA 2, L Enclosure ype 2 CE according to 24/8/EC Certification Certified to IEC/EN 673- and IEC/EN clus according to L 673-A and L and CAN/CSA E673-:2 Mode of operation ype.8kv Ambient temperature C (no restrictions) C (with restrictions)* Non-operating temperature C Ambient humidity 95% r.h., non-condensating Dimensions / Dimensions See «Dimensions» Approx..kg * nder these operating conditions, the lift cycle of actuator will be reduced. Please contact your Belimo representative for details * * Option (accessory K-SA) When using an auxiliary switch or feedback potentiometer V Subject to modification

2 NMQ24A-SR Modulating damper actuator for adjusting air control dampers in ventilation and air-conditioning systems for building services installations orque 8Nm Nominal voltage AC/DC 24V Control: modulating DC ()2...V Position feedback DC 2...V Running time 4s echnical data Electrical data Nominal voltage, 5/6Hz / DC 24V AC V / DC V nominal torque 2W 23VA (I max. 5ms) Cable m, 4 x.75mm² Functional data orque (nominal torque) Min. nominal voltage Control Control signal Operationg range DC ()2...V, input impedance kω DC 2...V Position feedback (Measuring voltage) DC 2...V, max..5ma Position accuracy ±5% Reversible with switch / Direction of motion at = V At switch position resp. Gearing latch disengaged with pushbutton, can be locked limiting min. 3 Running time 4s / 9 Automatic adjustment of operating range and measuring signal to match the mechanical angle of rotation Manual triggering of the adaption by pressing the «Adaption» button db(a) Negative torque 5% from nominal torque (with restrictions)* Safety Protection class III Safety extra-low voltage L Class 2 Supply IP54 in any mounting position NEMA 2, L Enclosure ype 2 CE according to 24/8/EC Certification Certified to IEC/EN 673- and IEC/EN clus according to L 673-A and L and CAN/CSA E673-:2 Mode of operation ype.8kv Ambient temperature C (no restrictions) +5 C (with restrictions)* Non-operating temperature C Ambient humidity 95% r.h., non-condensating Dimensions / Dimensions See «Dimensions» Approx..2kg * nder these operating conditions, the lift cycle of actuator will be reduced. Please contact your Belimo representative for details V Subject to modification 43

3 NMQ24A-SR * * Option (accessory K-SA) When using an auxiliary switch or feedback potentiometer V Subject to modification

4 NMD23A Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations orque 8Nm Nominal voltage AC...24V Control: Open-close or 3-point Running time 2s echnical data Electrical data Nominal voltage AC...24V, 5/6Hz AC V nominal torque W 5.5VA Cable m, 3 x.75mm² Functional data orque (nominal torque) Min. nominal voltage Reversible with switch or Gearing latch disengaged with pushbutton, detentable Running time 2s / 9 Max. 55dB(A) Safety Protection class II otally insulated IP54 NEMA 2, L Enclosure ype 2 Low voltage directive CE according to 24/8/EC CE according to 26/95/EC Certification Certified to IEC/EN 673- and IEC/EN clus according to L 673-A and L and CAN/CSA E673-:2 Mode of operation ype 4kV Ambient temperature range C Non-operating temperature C Ambient humidity range 95% r.h., non-condensating Dimensions / Dimensions See «Dimensions» Approx..85kg V Subject to modification ) ) 8 2 ) CrNi (INOX)

5 Wiring diagrams-general Damper Actuator Wiring diagrams: Open/Close actuators parallel connection possible, please note the performance data -wire control + DC 24V (while direction of rotation reverses) 2-wire control + DC 24V (while direction of rotation reverses) 2 3 S S2 S3 S S2 S3 S S2 S3 2 3 S S2 S3 S S2 S3 S S2 S3...% LM24A-S, LM24-S, NM24A-S NM24-S SM24A-S SM24-S...% LM24A-S, LM24-S, NM24A-S NM24-S SM24A-S SM24-S LM24A(-P/-F), LM24(-/-F), NM24A(-P), NM24(-), SM24 SM24A GM24A, GM24, LMQ24A, LMQ24, NMQ24A, NMQ24, SMQ24A SMQ24 LM24A(-P/-F), LM24(-/-F), NM24A(-P) NM24(-) SM24A, SM24, GM24A* GM24* N L AC...24V N L AC...24V 2 3 S S2 S3 S S2 S3 S S2 S3 2 3 S S2 S3 S S2 S3 S S2 S3...% LM23A-S, LM23-S, NM23A-S, NM23-S SM23A-S SM23-S...% LM23-S, NM23-S NM23A-S, SM23A-S SM23-S LM23A(-P/-F), LM23(-F), NM23 NM23A(-P) SM23A, SM23(-F), SMD23A, SMD23, GM23A GM23 LM23A(-F), LM23(-F), NM23A, NM23(-F) NMD23A SM23A, SM23(-F), SMD23A, SMD23, GM23A* GM23* *GM.. *GM..A.. only only for for Open/Close Open/Close application. application. Wiring diagrams: Modulating actuators parallel connection possible, please note the performance data Position - signal voltage + DC 24V DC ()2...V % of 95 Reversing switch = Reversing switch = DC 2...V Open Open Closed Closed + LM(Q)24A-SR, LM(Q)24-SR, NM(Q)24A-SR, NM(Q)24-SR SM(Q)24A-SR, SM(Q)24-SR, GM24A-SR GM24-SR 2 5 [ V ] anti-clockwise -closing damper clockwiseclosing damper N L AC...24V power output DC ()2...V DC 2...V V Subject to modification LM23ASR, LM23SR, NM23ASR NM23SR SM23ASR SM23SR 87

SM24A. Technical data. Dimensions [mm]

SM24A. Technical data. Dimensions [mm] SM24A Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services orque 2Nm Nominal voltage AC/DC 24V Electrical data Nominal voltage AC 24V, 5/6Hz / DC

More information

Technical data. Safety notes

Technical data. Safety notes echnical data sheet SM4A-S-P Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque Nm Nominal

More information

Technical data. Safety notes

Technical data. Safety notes echnical data sheet SMA-S-P Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque m ominal voltage

More information

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz GR24A-5 / -7 GR24A-5 Rotary actuator for rotary valves GR24A-7 Rotary actuator for rotary valves Nominal torque 40Nm Nominal voltage AC/DC 24V Control Open-close echnical data Electrical data Nominal voltage

More information

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch echnical data sheet Damper actuator NM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up

More information

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch echnical data sheet Damper actuator LM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up

More information

Non-Spring Return SMU... series

Non-Spring Return SMU... series Non-Spring Return SMU... series Product overview New Generation Non-spring return actuator Open/Close, 3-point AC 24 V 5/6 Hz, DC 24 V Auxiliary switch build-in SPD AC..24 V 5/6 Hz AC 23 V 5 Hz (Open/Close)

More information

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool echnical data sheet LHA-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency echnical data sheet NRA Rotary actuator for ball valves Nominal torque Nm Nominal voltage AC V Control Open-close, -point echnical data Electrical data Nominal voltage AC V Nominal voltage frequency 5/6

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V echnical data sheet SH24A-SR.. Modulating linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m 2 Actuating

More information

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive Technical data sheet NFU Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations Torque: 10Nm Nominal voltage: AC 4... 40V DC 4...15V

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SFG- Spring return actuator with emergency function in the IP66 I protective protecti e housing for adjusting air dampers in industrial plants and in technical building installations

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage AC/DC

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet FA actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage

More information

See «Overview of types»

See «Overview of types» echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m Actuating

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SF24G-S- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building

More information

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3 SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage

More information

2. A E LM Form-fit versions Linear adapter ZH-LM

2. A E LM Form-fit versions Linear adapter ZH-LM Actuators for heating, ventilation, air-conditioning 2. A1-90122 - E LM Form-fit versions Linear adapter ZH-LM OEM at001707 at00205 Linear adapter ZH-LM: For LM2... damper actuators with universal spindle

More information

Nominal voltage Nominal voltage range Power consumption Wire / tranformer sizing. Connection: Motor LMU24(-S/-F) Cable 1m, 3x0.

Nominal voltage Nominal voltage range Power consumption Wire / tranformer sizing. Connection: Motor LMU24(-S/-F) Cable 1m, 3x0. LMU24(S/F/) For operation of air control dampers in HVAC system orque: 5Nm Nominal voltage: AC/DC 24V Control: Open/Close or 3point echnical data Electrical data Functional data Working conditions Nominal

More information

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch echnical data sheet SF24G-S-S2- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building

More information

Actuators for heating, ventilation, air-conditioning 2. LM-4 -CD. Product Information Damper actuators. i

Actuators for heating, ventilation, air-conditioning 2. LM-4 -CD. Product Information Damper actuators. i Actuators for heating, ventilation, air-conditioning. LM-4 -CD Product Information Damper actuators LM i689 he complete range of damper actuators for general use in HVAC systems ype LM NM SM AM GM LF AF

More information

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return echnical data sheet FA-S2 actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage

More information

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx 4 m 2 orque 20 m ominal voltage AC/DC

More information

Power consumption In operation At rest For wire sizing. Non-operating temperature

Power consumption In operation At rest For wire sizing. Non-operating temperature echnical data sheet DRC4G--7 Rotary actuator for butterfly valves for outdoor applications orque 90 Nm (not constant) Nominal voltage AC/DC 4 V Control: Open-close IP66 Optimum protection against moisture

More information

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 00 to 40 VAC Torque min. 60 in-lb for control of damper surfaces up to 90 sq ft. Application For on/off and floating point control of dampers

More information

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor Technical data sheet GK24G- SuperCap rotary actuator with emergency setting function and extended functionalities in the IP66 protective housing for adjusting air dampers in ventilation and air-conditioning

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet LHK24A-SZ Modulating SuperCap linear actuator with emergency setting function and extended functionalities for adjusting air dampers and sliders in ventilation and air-conditioning

More information

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma LMX0-SR Proportional Control, Non-Spring Return, Direct Coupled,00 to 0 VAC, for to 0 VDC and to 0 ma Torque min. 5 in-lb for control of damper surfaces up to sq ft. Application For proportional modulation

More information

Characterised Control Valves with Actuators

Characterised Control Valves with Actuators Characterised Control Valves with Actuators echnical Databook Version 6.2 Belimo Asia Pacific Product Overview and able of Contents able of Contents 2 Control Valves and Actuators Product Overview 3 Characterised

More information

Overview of types. Technical data. Safety notes

Overview of types. Technical data. Safety notes echnical data sheet LH4A-S-P.. Linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air dampers up to approx.

More information

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V LMB- (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 5 in-lb for control of damper surfaces up to sq ft. Technical Data LMB- on/off-floating Power Supply VAC ±

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB4-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 80 in-lb for control of damper surfaces up to 45 sq ft. Application For on/off and floating point control of

More information

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For proportional modulation of dampers

More information

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1. LMCB4-SR (-T) Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMCB4-SR LMCB4-SR-T HALOMO Brushless

More information

Technical data sheet. Technical data. Safety notes

Technical data sheet. Technical data. Safety notes echnical data sheet NM24P Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..6 m 2 orque 8 Nm Nominal voltage

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB-(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 80 in-lb for control of damper surfaces up to 5 sq ft. Application For on/off and floating point control of dampers

More information

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor echnical data sheet SHK24A Linear actuator with capacitor technology for adjusting air dampers and sliders with emergency control function and extended functionalities in ventilation and air-conditioning

More information

Minimum 18 in-lb Torque

Minimum 18 in-lb Torque CM Series Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM CMB Series - At A Glance CMB24-3 (p. 311) CMB24-3-T (p. 311) CMB120-3 (p. 313) CMB24-SR-R

More information

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology NMB (X) -MFT Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Torque min. 90 in-lb for control of damper surfaces up to sq ft. Technical Data NMB(X)-MFT Power Supply

More information

Versatile and Powerful

Versatile and Powerful AM Series Direct Coupled Actuator Versatile and Powerful Minimum 180 in-lb torque in a compact package. For damper areas up to 45 sq-ft* All Actuators have BDCM AM Series - At A Glance AMB(X)24-3 (p. 148)

More information

Spring-Return Damper Actuator NF24(-S)

Spring-Return Damper Actuator NF24(-S) Spring-eturn Damper Actuator NF24(-S) For operation of air control dampers that perform safety function Torque: 7Nm Nominal voltage: AC/ Control: Open/Close Integrated auxiliary switch NF24-S Technical

More information

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency Technical data sheet NFG-S2-L Spring-return actuator with emergency control function for adjusting dampers in technical building installations Air damper size up to approx. 2 m² Nominal torque 10 Nm Nominal

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing echnical data sheet LH4A.. Linear actuators for operating air control dampers and slide valves in ventilation and air-conditioning systems For air control dampers up to approx. m Actuating force 5 ominal

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SHA.. inear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. m Actuating force 45 ominal voltage

More information

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology NMQB-MFT, NMQX-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Application For proportional modulation of dampers in HVAC systems. Actuator sizing should

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency Technical data sheet DRK24A-5 SuperCap rotary actuator with emergeny control function and extended functionalities for butterfly valves Nominal torque 9 Nominal voltage AC/DC 24 V Control Open-close Design

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature echnical data sheet SR24P-R Robustline rotary actuator for butterfly valves and rotary valves in Retrofit applications orque 18 Nm Nominal voltage AC/DC 24 V Control: Open-close or 3-point Optimum protection

More information

Versatile and Powerful

Versatile and Powerful LM Series Direct Coupled Actuator Versatile and Powerful Minimum 45 in-lb torque in a compact package. For damper areas up to 11 sq-ft* Actuators in bold have BDCM LM Series - At A Glance LMB(X)24-3(-S)(-T)

More information

Power consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40...

Power consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40... echnical data sheet SM24P-S Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..2 m 2 orque 8 Nm Nominal

More information

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in ventilation and air conditioning

More information

Attachments. Open/Close actuators. For the opening and closing of dampers in air conditioning. 06/2017 DE/en PD OC 1

Attachments. Open/Close actuators. For the opening and closing of dampers in air conditioning. 06/2017 DE/en PD OC 1 X X testregistrierung Attachments For the opening and closing of dampers in air conditioning systems Actuators for Type JZ, JZ-AL, JZ-LL, JZ-LL-AL, JZ-HL, JZ-HL-AL multileaf dampers Change of the damper

More information

Minimum 27 in-lb Torque

Minimum 27 in-lb Torque LU Series Actuator Minimum 27 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM LU Series - At A Glance LUB(X)24-3 (p. 351) LUX120-3 (p. 353) LUB(X)24-SR (p. 355) LUX120-SR (p.

More information

Fire and Smoke Damper Actuator product overview

Fire and Smoke Damper Actuator product overview Fire and Smoke Damper Actuator product overview Fire and Smoke protection Spring-Return Actuator BLF.. BF.. BFG.. FSLF..US FSNF..US FSAF..US Agency listing CE certification UL555 and UL555S Torque - Motor

More information

LMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V LMX4- (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMX4- LMX4--T Application For on-off and floating point

More information

Minimum 27 in-lb torque

Minimum 27 in-lb torque LU Series Actuator Minimum 27 in-lb torque For damper areas up to 6.8 sq-ft* All Actuators have BDCM LU Series - At A Glance LUB(X)24-3 (p. 258) LUB(X)24-SR (p. 260) LUX24-MFT (p. 262) Basic Product Flexible

More information

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC 24 V Nominal voltage frequency Technical data sheet Globe valve actuator with emergency control function for 2-way and 3-way globe valves Actuating force N Nominal voltage AC 24 V Control 3-point Nominal stroke 2 mm Design life SuperCaps:

More information

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V NFB4, NFB4-S, NFX4, NFX4-S On/Off, Spring Return, 4 V Torque min. 90 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection NFB4... NFX4...

More information

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21) EFB and EFX Series Spring Return Direct Coupled Actuator Minimum 70 in-lb Torque For damper areas up to 66 sq-ft* (For lower torque, see AFB, AF, NFB, LF, or TF series) Applications New standard clamp

More information

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators The ZG-JSL jackshaft linkage is designed to easily attach to any part of a jackshaft and allow easy installation

More information

Butterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific

Butterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific Butterfly Valves Technical Databook Version 7.2 Belimo Asia Pacific BFV and Actuators Product Range Overview and Applications BU6..Series Motorised Butterfly Valves page 4 BU6..Series Butterfly Valves

More information

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor

More information

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point Actuators Technical data sheet Rotary drive Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor Nominal Voltage Control Damper size Damper

More information

Technical data. Safety notes

Technical data. Safety notes echnical data sheet MP-S Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx 6 m orque 8 m ominal voltage

More information

Damper Actuators Non-Spring Return

Damper Actuators Non-Spring Return 50 Non-Spring Return MD5A, MD10A, MD20A, MD40A The MD.A series are 2-10V modulating damper actuators designed for operating air control dampers in ventilation and air conditioning systems for building

More information

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific Globe Valves Technical Databook Version 1.2 Belimo Asia Pacific Contents Globe Valves Product Overview Max. Close-off Pressure - Globe Valve Series Globe Valve Actuators Product Overview 4 5 General Information

More information

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of spring return actuator Description Spring-return actuator for adjusting and regulating dampers and valves in air conditioning and ventilation. Torque

More information

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators Datasheet 53lb-in (6 Nm), Non-Spring Return Damper Actuators Overview The direct-coupled fail-safe/failin-place electronic actuators are designed for modulating, two position, and floating control of laboratory

More information

Product Cross Reference

Product Cross Reference AF120 US, AF120-S US AF230 US, AF230-S US AFBUP, AFBUP-S, AFXUP, AFXUP-S Torque 133 in-lb [15 Nm] minimum 180 in-lb. [20 Nm] minimum OPERATION Running Time Noise Level < 75 seconds

More information

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends Application Water-side control of heating and cooling systems for AHUs and water coils. Equal Percentage/

More information

Mounting Installation Instructions LM, NM, AM, GM

Mounting Installation Instructions LM, NM, AM, GM 709-0000 Rev G Mounting Installation Instructions LM, NM, AM, GM General Information Preliminary steps. Belimo actuators with NEMA or NEMA ratings should be mounted indoors in a dry, relatively clean environment

More information

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4. TF Series Spring Return Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 4.5 sq-ft* Applications Cost effective quality and performance for a range of applications including: Classroom

More information

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator NFB and NFX Series Spring Return Direct Coupled Actuator Minimum 90 in-lb Torque For damper areas up to sq-ft* Applications 1 3/4 1/ New standard clamp fits standard 1/ shafts to 1.05 jackshafts. Mount

More information

LF Series Spring Return Direct Coupled Actuator

LF Series Spring Return Direct Coupled Actuator LF Series Spring Return Direct Coupled Actuator Minimum in-lb torque LF actuator For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including:

More information

FSAF24(-S) US, FSAF120(-S) US

FSAF24(-S) US, FSAF120(-S) US FSAF4(-S) US, FSAF10(-S) US On/Off, Spring Return, Meets 50 F [11 C] for Half Hour, 75 Seconds Torque min. 133 in-lb, for control of air dampers Technical Data FSAF4(-S) US, FSAF10(-S) US Power supply

More information

Long Throw Nozzle WDA

Long Throw Nozzle WDA Long Throw Nozzle WDA Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Characterised Control Valves with Actuators

Characterised Control Valves with Actuators Characterised Control Valves with Actuators Technical Databook Version 8.6 Belimo Asia Pacific Contents Control Valves and Actuators Product Overview 4 Characterised Control Valve 6 Sizing of Ball Valves

More information

BELIMO CONTROLS

BELIMO CONTROLS INDEX ACCESSORIES MECHANICAL CRANK ARM ADAPTOR KITS... 7-17 JACKSHAFT LINKAGE FOR SPRING RETURN DAMPER ACTUATORS... 7-17 MISCELLANEOUS... 7-17 MOUNTING BRACKETS... 7-17 DAMPER ACTUATORS FIRE AND SMOKE

More information

ADM 322: Rotary actuator

ADM 322: Rotary actuator Product data sheet 3.1 51.332 ADM 322: Rotary actuator How energy efficiency is improved Best operating convenience, precision activation and high energy efficiency with minimal operating noise. Features

More information

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges and outputs 0 to 5/10 V or 4 to 20 ma. NEMA 4X / IP65 rated enclosure. For monitoring the differential pressure

More information

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return.

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return. Actuators for heating, ventilation, air conditioning 2. F-2 -CD Product Information Damper actuators with spring return F i6772 Contents Selection table orque 4 Nm F24 F24-S F23 F23-S F24-3 F24-S Nominal

More information

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating General Instructions DuraDrive MF4-653/MS4-653 Series Non-spring Return Rotary Electronic Damper Actuators 4 Vac Three-position/Modulating Description The DuraDrive direct-coupled, 4 Vac, non-spring return

More information

Direct Coupled Damper Actuator Model MY6050A1001

Direct Coupled Damper Actuator Model MY6050A1001 Specifications/Instructions Direct Coupled Damper Actuator General direct coupled damper actuator is a motorized actuator to open/close a damper. Model MY6050A00 provides -position or floating control

More information

MF /MS Series

MF /MS Series MF41-6153/MS41-6153 Series 24 Vac, Three-position/Modulating Non-spring Return Rotary Electronic Damper SmartX Actuators General Instructions Description The direct-coupled, 24 Vac, non-spring return electronic

More information

GM Series Direct Coupled Actuator

GM Series Direct Coupled Actuator GM Series Direct Coupled Actuator Minimum 3 in-lb torque** For damper areas up to 8 sq-ft* Applications Linkage is part of inlet vane assembly supplied by manufacturer. Actuator is mounted to vortex frame.

More information

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper Volume Control Dampers Incorporating Series HVC-VCD Excellent general purpose volume control damper Lightweight aluminium construction Fully protected linkage system positioned outside of airstream Very

More information

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No Document No. 155-521 (For Use with 2-1/2-Inch to 6-Inch Pressure Independent Control Valves) Features Operating voltage: AC/DC 24V Application Control signals: 3-position, DC 0 to 10V, DC 4 to 20 ma Fail-safe

More information

Accessories. Technical Data Extension Height 2" Material. Stainless Steel. Bearing TR LRB (X) ARB (X) TF LF AF. Extension Bracket CCV-EXT-Kit

Accessories. Technical Data Extension Height 2 Material. Stainless Steel. Bearing TR LRB (X) ARB (X) TF LF AF. Extension Bracket CCV-EXT-Kit The CCV-EXT-KIT can be used with most CCV s* and PICCV in order to achieve a large clearance over the pipe. The Extension Kit will provide an additional 2 of space between the top of the valve and the

More information

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND TWO-POSITION CONTROL

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND TWO-POSITION CONTROL N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND TWO-POSITION CONTROL SPECIFICATIONS PRODUCT DATA Supply voltage CN6105/CN6110 Nominal voltage CN6105/CN6110 24 Vac/dc

More information

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper Halton UTK, UTT Multi-blade Damper Temperature operation range up to +100 C, optionally up to +200 C Galvanised steel design Classification of casing leakage EN 1751 class B UTK: Shut-off, adjustment,

More information

Output signal active humidity DC V 22DTH-51MB DC V, DC V DC V DC V DC V DC V

Output signal active humidity DC V 22DTH-51MB DC V, DC V DC V DC V DC V DC V Duct Sensor Humidity / Temperature Duct mounted combined humidity (VDC) and temperature sensor. 2% accurate rh, available with dual active outputs or passive for temperature. Nema 4X / IP65 rated enclosure.

More information

Direct Coupled Damper Actuator Model MY9050A1001

Direct Coupled Damper Actuator Model MY9050A1001 AB-4 Specifications/Instructions Direct Coupled Damper Actuator Model MY9050A00 General Model MY9050A00 direct coupled damper actuator is a motorized actuator to open/close a damper. Model MY9050A00 contains

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100

More information

Table of Contents PAGE General Mounting Standard Reversible Clamp Linear Rotary Retrofit Brackets...275

Table of Contents PAGE General Mounting Standard Reversible Clamp Linear Rotary Retrofit Brackets...275 Installation and Operation Non-Spring Return General Information Table of Contents PAGE General Mounting Standard...7 Reversible Clamp...7 Linear...7 Rotary...73 Retrofit Brackets...75 Operation Electrical...76

More information

Electro Controls. Damper Actuators / Valve Motors WattsIndustries.co.uk

Electro Controls. Damper Actuators / Valve Motors WattsIndustries.co.uk Electro Controls Damper Actuators / Valve Motors - 2017 WattsIndustries.co.uk Damper Actuators / Valve Motors Section 21 DAMPER / VALVE MOTORS 4Nm 2 & 3 POINT EK4.. These small motors can be fitted directly

More information

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating Volume Control Dampers Incorporating Series LF upvc-vcd 2.76 m 3 /hr/m 2 leakage at 50 Pa, over 70% better than required by Part L of Building Regulations Corrosion resistant, perfect for chlorinated atmospheres

More information

AKM 105, 115: Rotary actuator for ball valve

AKM 105, 115: Rotary actuator for ball valve Product data sheet 51.363 AKM 105, 115: Rotary actuator for ball valve Improving energy efficiency Torque-dependent cut-off facility for efficient usage of energy Features For actuating 2- and 3-way ball

More information

Butterfly Valves. Technical Databook. Belimo Asia Pacific

Butterfly Valves. Technical Databook. Belimo Asia Pacific Butterfly Valves Technical Databook Version 6 Belimo Asia Pacific Index BFV and Actuators Product Range Overview and Applications BU6..Series Motorised Butterfly Valves BU6..Series Butterfly Valves General

More information

Mechanical Fail-Safe Damper Actuator NFA

Mechanical Fail-Safe Damper Actuator NFA 2-FON echnicl Fil-Sfe Dmper Actutor NFA ctutor emergency function for djusting ir dmpers in ventiltion nd ir conditioning systems in uildings orque Nm Nominl voltge AC 24..4V / DC 24..V Control: Open-close

More information

S1024-2POS / S POS S2024-2POS / S POS

S1024-2POS / S POS S2024-2POS / S POS GENERAL S0-POS / S00-POS S0-POS / S00-POS SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 0/0 Nm (88/77 lb-in) FOR -POSITION CONTROL These direct-coupled damper actuators provide two-position control for:

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100

More information