Control Valve Accessories Low Pressure Switch
|
|
- Lenard Hardy
- 5 years ago
- Views:
Transcription
1 Control Valve Accessories Low Pressure Switch 4035 Goodwin Avenue, Los Angeles, CA (800) N.O. Low Pressure Switch Part # 5253 N.O./N.C. Low Pressure Switch Part # 5245 SWITCH SPECIFICATIONS: CONTACTS... N.O. ACTUATION PRESSURE ± 10 PSIG RELEASE PRESSURE ± 10 PSIG MAX PRESSURE (UL) PSIG MAX PRESSURE (NON-UL) PSIG BURST PRESSURE PSIG TEMPERATURE RANGE... AMBIENT: -20 F TO 150 F FLUID: -65 F TO 275 F ELECTRICAL RATING VAC - 13A, 13FLA, 65LRA, 480VA VAC - 10A, 10FLA, 45LRA, 720VA DIELECTRIC STRENGTH VRMS OPEN SWITCH 1550 VRMS TERMINALS TO SWITCH UL RECOGNIZED... FILE SA995, GUIDE SDFY 2 UL CANADA RECOGNIZED... FILE SA995, GUIDE SDFY 8 SWITCH CONFIGURATIONS SPST AT ATMOSPHERIC PRESSURE: OPEN THE MECHANICAL CONNECTION IS 1/8-27 F MALE CONNECTION. LEAD WIRES ARE 72" ± OF #18 AWG WITH INSULATION RATED FOR 105 IN OIL. Page 74 - EECO Control Valve Catalog (Revised, )
2 Control Valve Accessories (continued) Control Valve Fittings B D F H A C E G J The Pressure Gauge Fittings are available to provide a means of attaching a Pressure gauge and or Pressure Switch to the Control Valve. All threaded fittings are 1/8 brass. ITEM PART NO. DESCRIPTION A PSI LIQUID FILLED PRESSURE GAUGE ASSEMBLY B P10201 FEMALE QUICK DISCONNECT C P10202 MALE QUICK DISCONNECT D P10203 HEX NIPPLE E P10204 SHUTOFF VALVE F P10206 COUPLING G P O ELBOW H P10208 TEE J P10209 ADAPTER Self Closing Manual Lowering Valve The Self Closing Manual Lowering Valve can replace the current Manual Lowering in all EECO Control Valves. To open the Self Closing Manual Lowering Valve the knob needs to be turned a 1/4 turn counter clockwise (CCW). Once the knob is released, the manual lowering valve will automatically close. Because of the 1/4 turn and automatic closing features, the manual lowering valve can be adapted for machine roomless or hard to reach installations. Part No EECO Control Valve Catalog (Revised, ) - Page 75
3 Control Valve Accessories (continued) Control Valve Adjusting Tools The Combination Valve Adjusting Wrench is a handy tool used to make the neccesary adjustments to any EECO Control Valve. This tool has a convient pen climp to store in your pocket. Part No The Valve Adjusting "Z" Wrench is a tool used to make the neccesary fine tuning adjustments to any EECO Control Valve. Part No. #### The Valve Troubleshooting Guide is a quick reference guide to common issues with control valves found in hydraulic elevators. It provides symptoms and solutions for most problems that may arise. This guide is laminated to prevent destruction with contact of oil. For assistanace with troubleshooting contact EECO at (888) Model No. UV-TSG The Power Unit Valve Adjusting Kit was created to provide the mechanic with the tools to troubleshoot and adjust an EECO Control Valve. The DVD includes a step by step training of the UV-5AT, as well as other helpful documentation about other EECO products. Model No. UV-VAK Page 76 - EECO Control Valve Catalog (Revised, )
4 Machine Room Components & Accessories MODEL NO OIL LINE SIZE INLET TYPE OUTLET TYPE LENGTH EHD 20GG EHD 20TG 2" 14" EHD 20TT EHD 25GG EHD 25TG 2.5" EHD 25TT EHD 30GG 14.5" EHD 30TG 3" EHD 30TT The Hydraulic Dampener (EHD) is extremely effective in suppressing the sound and pulsation present in hydraulic elevator systems. The EHD has a minimum burst pressure of 6000 psi with an ASME A17.1/CSA B44 allowable working pressure of 1200 psi. Unit diameter is 8-5/8 and the length varies based on outlet size. (See chart above) MODEL NO INLET SIZE OUTLET SIZE INLET TYPE OUTLET TYPE DIAMETER MU 2020GG MU 2020GT 2" 2" 6.63" MU 2020TT MU 2525GG MU 2525GT 2.5" MU 2525TT 2.5" MU 2530GG 3" MU 2530GT 8.63" MU 3030GG MU 3030GT 3" 3" MU 3030TT The Muffler (MU) provides superior noise suppression for most standard power unit installations. The unit working pressure is 1200 psi and it is 11-3/4 long. Unit diameter for 2 size is 6-5/8 and 8-5/8 for other sizes. MODEL NO OIL LINE SIZE INLET TYPE OUTLET TYPE DIAMETER ISO 20GG ISO 20GT 2" 5" ISO 20TT ISO 25GG ISO 25GT 2.5" 6.88" ISO 25TT ISO 30GG ISO 30GT 3" 7.38" ISO 30TT The Isolation Coupling (ISO) is available in three sizes to help reduce noise and vibration from being transmitted to the cab and also provides electical isolation. 2 Isolation Couplings are rated at 1200 psi, 2.5 and 3 are rated at 1000 psi. Each isolation coupling has a dielectric of 25kv. EECO Control Valve Catalog (Revised, ) - Page 77
5 Machine Room Components & Accesories (continued) MODEL NO OIL LINE SIZE INLET TYPE GPM RANGE PRV 075G.75" PRV 075T 2 26 PRV 100G 1" PRV 100T PRV 150G 1.5" PRV 150T PRV 200G 2" PRV 200T PRV 250G 2.5" PRV 250T PRV 300G 3" PRV 300T The Pipe Rupture Valve (PRV) is a simple but effective way to achieve a quick and smooth stopping of a car if an overspeed of the elevator should occur. The PRV is connected directly to the pressure line between the control valve and the jack. The supplied connections on the PRV make installation quick and easy. The PRV comes with either or grooved connections. See chart for sizes and gpm ranges available. MODEL NO OIL LINE SIZE INLET TYPE PORT SOV 20GF FULL SOV 20GR REDUCED 2" SOV 20TF FULL SOV 20TR REDUCED SOV 25GF FULL SOV 25GR REDUCED 2.5" SOV 25TF FULL SOV 25TR REDUCED SOV 30GF FULL SOV 30GR REDUCED 3" SOV 30TF FULL SOV 30TR REDUCED The Shut Off Valve (SOV) is used to isolated one section of the system from another. All Shut Off Valves are constructed of ductile iron bodies and use a stainless steel ball. A locking device is standard on all sizes. MODEL NO OIL LINE SIZE LWK 20 2" LWK " LWK 30 3" LWK 40 4" EECO s Load Weighing Kit (LWK) is an addition to a new or existing Power Unit to prevent the elevator from being overloaded. The switch can be wired into the controller, if the provision is available, through either a normally open or normally closed contact. The kit consists of a field adjustable pressure switch with 48 wire leads, a 4-1/2 long grooved nipple (2, 2-1/2, 3, & 4 sch 80), a 1/2 flex 90 screw-in conduit fitting, and (3) 5-0 extensions of 18 awg wire with butt splices and #8 spade terminals. Load Weighing Switch also available separately. Part No Page 78 - EECO Control Valve Catalog (Revised, )
6 Machine Room Components & Accesories (continued) MODEL NO OIL LINE SIZE CONNECTION TYPE VRF 20F FEMALE VRF 20M 2" MALE VRF 20G VRF BAG REPLACEMENT BAG The Valve Return Filter (VRF) is a passive oil filtration system attached to the tank return port of the valve. The filter bag is easily replacable without having to remove the filter bag flange. The VRF allows you to easily comply with ASME A17.1/CSA B44 Rule by capturing particles 5 microns in size and larger, preventing the buildup of debris within the tank making it easier to clean. The filter bag is rated at 200 gpm. The top of the flange is to be located no more than 16 3/4" from the minimum oil level. See chart for model numbers and configurations available. The Oil Cooler (OC) is extremely efficient in cooling the oil in the hydraulic elevator machine room in which it is installed. The heart of the unit consists of a triple screw pump which is highly reliable and quiet. As an added feature, to help safeguard the entire system, the pump is equipped with a safety valve set at 87 PSI to prevent a system overpressure. The oil is cooled using air produced by a helical fan mounted coaxial with the screw and pump motor. 9.3 GPM, 115/230VAC, 1 phase, BTU/h. Model No. OC-01 The Tank Heater (TH) is simple to install and operate. Designed to keep your hydraulic oil at the optimum operating temperature in cooler environments to provide optimum operation of your hydraulic elevator system. Pre-Set 110 F Thermostat, 120 Volt AC, 250 Watts, 2.1 Amps, Oil-Tight Fittings included. Model No. TH-01 K K Low Oil Float Sensor for hydraulic elevator power units is used to detect a low oil condition. This sensor can be used in addition or in place of Oil Sight Gauge Model No. LOS-1 L L The Low Oil Float Switch for hydraulic elevator power units is used to detect a low oil condition. This sensor can be used in addition or in place of Oil Sight Gauge. Model No. LOS-2 The Low Oil Sight Gauge for hydraulic elevator power units is used to visually inspect the oil level in the tank. It is available in 1" Diameter with threads. Part No EECO Control Valve Catalog (Revised, ) - Page 79
7 Machine Room Components & Accesories (continued) Replacement Submersible Pumps & Motors Submersible Pumps EECO can supply replacement pumps for Submersible Power Units. With many choices available EECO is sure to have the right size for your application. Our entire inventory of pumps range from 2.6 gpm up to 283 gpm. Submersible Motors EECO can supply replacement motors for Submersible Power Units. With many choices available EECO is sure to have the right size for your application. Single and three phase motors available with varied voltages and horsepower up to 60hp. Replacement Belt Drive (Dry) Pumps & Motors Belt Drive Pumps EECO can supply replacement pumps for Belt Drive (Dry) Power Units. With many choices available EECO is sure to have the right size for your application. Our entire inventory of pumps range from 36 gpm up to 317 gpm. Belt Drive Motors EECO can supply replacement motors for Belt Drive (Dry) Power Units. With many choices available EECO is sure to have the right size for your application. Single and three phase motors available with varied voltages and horsepower up to 125hp. Page 80 - EECO Control Valve Catalog (Revised, )
8 Hoistway Components & Accessories 4035 Goodwin Avenue, Los Angeles, CA (800) The Tape Selector (TS) is designed to replace older mechanical hoistway switches and bulky landing boxes, with easy installation and adjustment. MODEL NO DESCRIPITION LS 1B SINGLE CONTACT SPDT LS 1BD DOUBLE CONTACT DPDT LS 1BW SINGLE CONTACT WEATHER RESISTANT LS 1BDW DOUBLE CONTACT WEATHER RESISTANT LS 1BN SINGLE CONTACT NEMA 4 LS 1BDN DOUBLE CONTACT NEMA 4 The Limit Switch (LS) is designed primarily for use in elevator hoistways as Access, Slow Down, Normal, and Final Limits. The light weight durable construction of the LS-1B results in a reduced noise level and is designed for repeated reliability. Switches are available in two configurations, SPDT with one normally open & one normally closed contacts and DPDT with two normally open & two normally closed contacts. MODEL NO DESCRIPITION MV 4C SINGLE CONTACT SPDT MV 4CD DOUBLE CONTACT DPDT MV 4CN SINGLE CONTACT NEMA 4 MV 4CDN DOUBLE CONTACT NEMA 4 The Permanent Magnet Switch (MV) is designed primarily for applications requiring trouble free service. This switch provides a cost effective and simple solution for environments where mechanical contact between the actuating vane and switch is not desired. Switches are available in two configurations, SPDT with one normally open & one normally closed contacts and DPDT with two normally open & two normally closed contacts. Mounting brackets and Clamp are available for mounting the LS and MV model switches to the rail. Brackets are designed to work with 8, 12, 15 pound rails. Part No. 9733A EECO Control Valve Catalog (Revised, ) - Page 81
9 Hoistway Components & Accessories (continued) EECO offers and assortment of Guide Shoe for your elevator. Rollers, Slide Guides, & Swivel are all available. Contact EECO for more details. EECO offers rail for installation in the hoistway. Contact EECO for more information. Manufactured of heavy gauge steel, this rail bracket is fully adjustable to conform to any requirement that you may have. Multiple configurations are possible with our unique and durable design. The 9" wide Rail Bracket is designed for 12lbs./ft. and 15lbs./ft. rails with adjustability from 2 1/2" to 5 1/4". They come with all hardware (5/8" bolts, washers, forged clips, and locking plate). Wall mounting hardware is not included. Part No Adjustable from 2 1/2" to 3 1/2" Part No Adjustable from 3 1/2" to 5 1/4" EECO offers rail clips for mounting rail to rail brackets in the hoistway. Contact EECO for more information. The Pendant Station is used during the construction of an elevator to raise and lower the installed platform. Customer provides wiring and connection to elevator controller. Part No Page 82 - EECO Control Valve Catalog (Revised, )
10 Hoistway Components & Accessories (continued) The Scavenger Pump (SP) has a ribbed, reinforced polyethylene container with a clear lexan top. Tank dimensions 15 W x 10 D x 8 H. 200 Micron filter. Flood control reset. UL approved motor and cord. The scavenger pump is available with a1/4 HP motor, with a 45 GPH pump. Model No. SP-45 We custom manufacture each car buffer to EECO s demanding standards of quality and durability. Each set of car buffers is designed and manufactured based on the requirements of a given job. You can be assured that the car buffers you receive are the correct ones for that specific installation. The Pipe Stand is a simple and economical design that allows the mounting of oil lines and electrical conduit clear of the pit floor. For 2, 2-1/2 & 3 hydraulic lines. Standard unit is 24 tall with clamps. Order by pipe size. Part No. #### EECO Control Valve Catalog (Revised, ) - Page 83
11 Pit Equipment Components & Accessories The Electronic Leak Monitoring System (ELMS) is designed to detect the leakage of either water or oil into the sealed PVC liner and also provides a manual monitoring method for verifying the leakage in the liner. NOTE: This system can only be utilized on new jack installations, or jack unit replacements, with sealed PVC liners. The Evacuation System (EVS) is to be used to evacuate / inspect fluid leakage into the cavity between the cylinder and PVC liner of an existing in-ground hydraulic jack system. The minimum required space between the cylinder and PVC should be 1/2". Model No. EVS-01 The Pit Ladder (PL) is design for four or five foot pit depth. Contact EECO for custom lengths. Model No. PL-01 EECO has a vast arrangement of Oil Line Components from Grooved Clamps, Tee Fittings, Reducers, and more. Also available are standardized Oil Line Kits which are available with the most common length of oil line and fittings. Contact EECO for more details. Page 84 - EECO Control Valve Catalog (Revised, )
12 Jack Unit Packing Sets 4035 Goodwin Avenue, Los Angeles, CA (800) Bearing O-Ring Seal Bearing Wiper Lantern Ring Install Ring To help with installation an Install Ring should be purhchased with every internal packing set JACK MODEL PISTON DIAMETER CONTENTS NJ " NJ 3NET TLJ TLJ LJ 3R LJ LJ LJ 4NET LJ LJ LJ 5NET LJ LJ LJ 6NET LJ LJ 7NET LJ LJ 8NET LJ LJ LJ LJ LJ LJ LJ PJ / PJR PJ / PJR 3NET PJ / PJR 3R PJ / PJR PJ / PJR 4NET PJ / PJR 4NET PJ / PJR PJ / PJR 5NET PJ / PJR PJ / PJR PJ / PJR 6NET PJ / PJR PJ / PJR 7NET PJ / PJR PJ / PJR 8NET PJ / PJR TJ TJ TJ TJ TJR 160 E TJR 250 E TJR 275 E TJR 400 E TJR 450 E TJR 160 I TJR 250 I TJR 275 I TJR 400 I TJR 450 I TJ3 160 E TJ3 250 E TJ3 160 I TJ3 250 I SEAL, 1 WIPER, 1 BEARING, 1 O RING 5 SEALS, 3 WIPERS, 3 BEARINGS, 5 O RINGS, 1 TRANSFER SEAL 2 SEALS, 1 WIPER, 1 LATERN RING, 1 BEARING, 2 O RINGS 1 SEAL, 1 WIPER, 1 BEARING, 1 O RING 3 SEALS, 3 WIPERS, 3 BEARINGS, 5 O RINGS, 1 TRANSFER SEAL 2 SEALS, 2 WIPERS, 2 BEARINGS, 4 O RINGS 2 SEALS, 1 BEARING, 1 TRANSFER SEAL 3 SEALS, 3 WIPERS, 3 BEARINGS, 6 O RINGS 4 SEALS, 2 BEARINGS, 2 TRANSFER SEALS E = EXTERNAL KIT ONLY I = INTERNAL KIT ONLY EECO Control Valve Catalog (Revised, ) - Page 85
13 More Great Products from EECO Belt Drive Power Units Submersible Power Units Residential Power Units Call EECO Sales today for a custom quote! (888) Page 86 - EECO Control Valve Catalog (Revised, )
14 More Great Products from EECO Single Stage Jack Units Two Stage Jack Units Three Stage Jack Units Call EECO Sales today for a custom quote! (888) EECO Control Valve Catalog (Revised, ) - Page 87
15 More Great Products from EECO Call EECO Sales today for a custom quote! (888) Car Slings & Platforms Complete & Group One Packages Passenger & Freight Page 88 - EECO Control Valve Catalog (Revised, )
Revised Hydraulic Elevator Control Valves...1. Hydraulic Elevator Control Valve Parts...2. EECO Heavy Equipment...3
Index SECTION Revised 8-6-09 PAGE Hydraulic Elevator Control Valves..................................................................1 Hydraulic Elevator Control Valve Parts...............................................................2
More informationElevator Equipment Corporation. Product Catalog
Elevator Equipment Corporation Product Catalog Revision 10-30-14 2014 About EECO West Coast Office 4035 Goodwin Avenue Los Angeles, CA 90039 (800) 423-2800 Mid-West Office 2230 N.W. 12th Street Richmond,
More informationElevator Equipment Corporation. Product Catalog. Revision
Elevator Equipment Corporation Product Catalog Revision 10-30-14 2014 Rev: 7/12/2017 About EECO West Coast Office 4035 Goodwin Avenue Los Angeles, CA 90039 (800) 423-2800 Mid-West Office 2230 N.W. 12th
More informationGroup One Roped Hydraulic. Elevators. as well as many other applications
Group One Roped Hydraulic Elevators as well as many other applications EECO Roped Dual Holeless EECO Roped Cantilever Holeless EECO Group One Components Hydraulic Jacks EECO manufactures jack units with
More informationFeatures and benefits. Normally open, normally closed contact logic
Pressure Switches Reliable pressure control by means of on / off electrical switch Normally open, normally closed contact logic Commercial and residential air conditioning systems The reliable and durable
More information37T Series Moisture Resistant Temperature Controls
37T Series Moisture Resistant Temperature Controls Moisture Resistant Temperature Control The 37T series of 3/4 (19mm) bimetal disc temperature controls from Therm-O-Disc offers proven reliability in a
More informationHYDRAULIC EQUIPMENT / fax
QUICK LOCATOR GUIDE Control Valves................................................ 270 Dampeners................................................... 268 Drip Ring.....................................................
More informationP66 Series Electronic Fan Speed Controls
FANs 125, 121 Pressure Controls Section P Product/Technical Bulletin P66 Issue Date 0498 P66 Series Electronic Fan Speed Controls The P66 is a pressure actuated electronic motor speed controller. This
More informationTRIPPING SPEED ADJUSTER (TS) CLOSING RATE ADJUSTER (CR)
OVERSPEED VALVE (PIPE RUPTURE / SHUT OFF VALVE) Introduction The Maxton Overspeed Valve (Pipe Rupture / Shut Off Valve) is designed to provide protection against supply line failure or over speed in the
More informationNew Fan Coil Piping Packages
New Fan Coil Piping Packages SO BUILT TOUGH, TOUGH. WE BUILT GUARANTEE TO LAST. IT. www.superiorrex.com Piping Packages Table of Contents General Notes and Legend... 3 Piping Package Code Descriptions
More informationVal-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual
Manual No. 5AOP-OM1-2 Val-Matic Air / Oil Hydraulic Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION...
More informationMF4E MF4E
MF4E-60830-100 TAC DuraDrive Non-Spring Return Floating Actuator General Instructions Application The 35 lb-in. (4 N-m) and MF4E-60830-100 70 lb-in. (8 N-m) non-spring return, direct-coupled actuators
More informationCoil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationMAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators
MAx-305 & MAx-38 Series MAx-405 Through MAx-49 Series Two-Position Actuators General Instructions Application For two-position operation of dampers, valves, and other equipment which require the return
More informationSeries P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits
PSC9919 European Refrigeration Controls Catalogue Catalog Section 6 Product Bulletin P100 Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty Introduction The P100 Series are
More informationSPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649
More informationIN-LINE HYDRAULIC FLOW TESTER
SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.powerteam.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031
More informationMODEL 5540 CONTENTS. Installation, Operation and Maintenance Instructions 1.0 GENERAL
Installation, Operation and Maintenance Instructions MODEL 5540 Sep 20 CONTENTS.0 GENERAL. Model Number---------------------------------------------------------------------------------------------------------------
More informationMA-5200 Series MA-5300 Series
MA-5200 Series MA-5300 Series Two-Position Actuators General Instructions Application The MA-5200 series and MA-5300 series actuators are used for two-position control of valves and dampers which require
More informationNECO Pumping Systems
INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems PACKAGED CIRCULATING SYSTEM THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED CIRCULATING SYSTEM IS OF THE HIGHEST QUALITY AND
More informationNEMA 4 High Pressure High Set Point High Accuracy Pressure Switch SPECIFICATIONS
Pressure Switches P605L NEMA 4 High Pressure High Set Point High Accuracy Pressure Switch OVERVIEW The Whitman Controls P605L NEMA 4 High Pressure High Set Point High Accuracy Pressure Switches are a line
More informationINSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR
Please refer to the Lancer web site (www.lancercorp.com) for information relating to Lancer Installation and Service Manuals, Instruction Sheets, Technical Bulletins, Service Bulletins, etc. INSTALLATION
More informationIntroduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits
PSC9919 European Refrigeration Controls Catalogue Catalog Section 6 Product Bulletin P100 Series P100 Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty.
More informationKW Submersible, Single-Vane Impeller
Sewage Pumps KW Submersible, Single-Vane Impeller Performance Curve Total Head (FT) Up to 2 Solids-Handling Heavy-Duty, Silicon Carbide Seals Stainless Steel Keyed Shaft Flows to 325 GPM / Heads to 95
More informationS P R AY E R VA L V E S AND C O N T ROL S C AT A L OG
Q UA L I T Y VA LV E S A N D C O N T R O L S. TO D AY A N D TO M O R R O W. Texas Industrial Remcor, Inc. CATALOG NO. 33 The new RC2 control system: Ensures no potential leaks in the tractor cab when using
More informationTYPE PC Propeller Condensate Pumps
SHIPPENSBURG PUMP CO. INC. P.O. BOX 279, SHIPPENSBURG, PA 17257 PH 717-532-7321 FAX 717-532-7704 WWW.SHIPCOPUMPS.COM BULLETIN 103 Revised 8/17 TYPE PC Propeller Condensate Pumps with Cast Iron Receivers
More informationRELEASING PRESSURE IN THE HYDRAULIC SYSTEM,
Testing And Adjusting Introduction NOTE: For Specifications with illustrations, make reference to SPECIFICATIONS for 225 EXCAVATOR HYDRAULIC SYSTEM, Form No. SENR7734. If the Specifications are not the
More informationOPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1
OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company 7/11 rev. 1 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200 F Buna-N -12.2
More informationSPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649
More informationOPERATION MANUAL. DUCTILE Models NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2
OPERATION MANUAL NT100 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS DUCTILE Models A JDA Global Company 5/13 rev.2 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200
More informationVA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features
TAC 1354 Clifford Avenue P.O. Box 2940 Loves Park, Illinois 61132-2940 www.invensysibs.com Two-Way and Three-Way Globe Valve Assemblies with 220 lbf Linear (979 N) Spring Return DuraDrive Actuators Submittal
More informationJo-Bell Products. DIVISION OF DALNOR SYSTEMS, INC Sierra Vista Drive Carlsbad NM, Phone: Fax:
Jo-Bell Products DIVISION OF DALNOR SYSTEMS, INC. 5325 Sierra Vista Drive Carlsbad NM, 88220 Phone: 575-628-0675 Fax: 575-628-0679 Jo-Bell Products has been producing liquid level controls since 1947,
More information91 \\SERVER\CATALOG 2018\2018 Catalog Rev 1 SHUT OFF BALL VALVE
SHUT OFF BALL VALVE Maxton Elevator Shut Off Valves are specifically built for hydraulic elevators and are labeled and tested to comply with ASME A17.1 / CSA B44 at a 5:1 Safety factor. BV2G2G SHOWN Hard
More informationNew Fan Coil Piping Package. Redefine your comfort zone.
New Fan Coil Piping Package PIPING PACKAGES Table of Contents General Notes and Legend...3 Piping Package Code Descriptions & Diagrams THB, THH and TVB Fan Coils...4 TVS Fan Coil, 2-Way...5 TVS Fan Coil,
More informationLIFEMIST NT WATER DISTILLER
LIFEMIST NT WATER DISTILLER REPLACEMENT PARTS MANUAL AND WIRING SCHEMATIC FOR MODEL: NT, LM-AED-1 & LM-APK-1 PART # 500033 500035 500034 SERIES 0014 0002 0001 02/08/11 PAGE 1 097079-S14A 02/08/11 PAGE
More informationCoil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationSPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347
More informationClass 9038 Type A Mechanical Alternator, Open Tank
Selection Guide Float Switches Class 9038 Type A Mechanical Alternator, Open Tank Type of Installation Product Features Horsepower rated 4-pole switch Standard action contacts close on liquid rise Reverse
More informationMYERS 4VCDP. 4" Solids Handling
MYERS 4VCDP Standard Submersible Dry Pit 4" Solids Handling Wastewater Pumps WWW.FEMYERS.COM TECHNICAL INFORMATION 2 SMOOTH OPERATION The 4VCDP submersible dry pit wastewater pumps are a heavy-duty 4"
More informationCommercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038
Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038 TM Table of Contents Table of Contents SELECTION GUIDE PUMPTROL COMMERCIAL PRESSURE SWITCHES...
More informationP70, P72, and P170 Controls for Low Pressure Applications
Master Catalog 125 Pressure Controls Section P Product/Technical Bulletin Issue Date 0900 P70, P72, and P170 Controls for Low Pressure Applications The P70, P72, and P170 controls for low pressure applications
More informationMX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories
MX4X-6XXX Series MX4X-7XXX Series Selection Guide DuraDrive Series Actuators and Accessories Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional
More informationThis catalog contains the following geothermal accessory products and specification guides:
f o r r e s i d e n t i a l s y s t e m s Geothermal systems offer an effective way to cut utility costs while ensuring comfort. Heat Controller s line includes two stage and single stage geothermal heat
More informationModel No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL
Model No. DFC-X Support 877-351-4702 DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This manual covers the following products: DFC-X TS-01 DFTD RDU DAT-12 PWM-10V
More information± ± ± ± ± ± ± ± 85.
Pressure Switches J705 High Pressure High Set Point Pressure Switch OVERVIEW The Whitman Controls J705 High Pressure High Set Point Pressure Switches are among our most durable products, affording the
More informationPortable Filter Carts Models 5MF and 10MF
s Models 5MF and 10MF 161 Applications for Parker Filter Carts Filtering new fluid before putting into service Transferring fluid from drums or storage tanks to system reservoirs Conditioning fluid that
More informationPIPING PACKAGES For Chilled and Hot Water Fan Coil Units
WWW.KRUEGER-HVAC.COM PIPING PACKAGES For Chilled and Hot Water Fan Coil Units PROVIDING YOU WITH AIR DISTRIBUTION AND EQUIPMENT SOLUTIONS TABLE OF CONTENTS General Notes... 4 Code Descriptions... 5 Guide
More informationINSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD
INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE B-3724M ACTUATOR MANIFOLD MIDLAND MANUFACTURING CORP. 7733 Gross Point Road Skokie, Illinois 60077 Phone (847) 677-0333 FAX (847) 677-0138 WEBSITE
More informationAccessories. Technical Data Extension Height 2" Material. Stainless Steel. Bearing TR LRB (X) ARB (X) TF LF AF. Extension Bracket CCV-EXT-Kit
The CCV-EXT-KIT can be used with most CCV s* and PICCV in order to achieve a large clearance over the pipe. The Extension Kit will provide an additional 2 of space between the top of the valve and the
More informationOPERATION MANUAL NT80 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2
OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company 5/13 rev.2 CAUTION SAFETY POINTS TEMPERATURE LIMITS: Neoprene -17.8 C to 93.3 C 0 F to 200 F Buna-N -12.2 C to 82.2 C 10 F to 180
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More informationElvoron Home Elevator
Creating An Accessible World Elvoron Home Elevator Design And Planning Guide www.garaventalift.com Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site
More informationPIPING PACKAGES TABLE OF CONTENTS
PIPING PACKAGES TABLE OF CONTENTS ITEM PAGE General Notes and Legend........................................................ 3 Piping Package Code Descriptions & Diagrams VAV Products and HL, HP, VF, and
More informationELVORON HOME ELEVATOR
Creating An Accessible World ELVORON HOME ELEVATOR PLANNING GUIDE www.garaventalift.com Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site preparation
More informationBALL VALVES. Industry-Leading 300psi Low Lead Ball Valves
BALL VALVES Industry-Leading 300psi Low Lead Ball Valves Designed and Manufactured to Meet Your Needs 1 Lockwing Accepts bullet lock (when equipped on meter valve). 2 Stainless steel reinforced seat gaskets
More informationVOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)
VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC) Document No. 129-464 VOG15 March 30, 2010 Description Oil Safety Shutoff Valve The VOG15 is an electro-hydraulically actuated
More informationSKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:
Performance RPM: 1550 Discharge: 2" Solids: 2" Wholesale Products Page: 6730-1 Section: Performance 8 25 7 20 HEAD-METERS 5 4 HEAD-FEET 15 4/10 HP 3 10 2 0 0 20 40 60 80 Capacity-U.S. G.P.M. Liters/Second
More informationHYDROSTATIC TEST SYSTEM MANUAL
PDQC HYDROSTATIC TEST SYSTEM MANUAL Technical Specification Operating Instructions Part List Revised 12-2016 Manual # PDQC- 6,000 And PDQC-10,000 1 PDQC PERFORMANCE DATA Model Number Maximum Pressure Volume
More informationSOLAR HEATING SYSTEM
SECTION 13600 SOLAR HEATING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07600 - Flashing and Sheet Metal. 2. 07900 - Joint Sealers. 3. 15260 - Thermal Insulation (Plumbing). 4. 15410 - Piping
More informationAtomizer 36-DC User Guide
TECHNICAL INSTRUCTIONS Atomizer 36-DC User Guide SERVICE CASE HUMIDIFICATION Specification Sheet... 2 Installation Guide... 3 Layout Diagram... 4 Maintenance Guide... 5 Wiring Diagram... 6 Pull Sheet...
More informationModel 5000 Level Controller
Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap
More informationCC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL
CC3060 TYPE 12 CC3060 13 lbs 9,300 0.3 1 x 6 30 x 8-3/4 x 4 Efficiency: 68.8 Watts / C T based on average internal cabinet temperature. 2. CC3060 Rated cooling: 2,725 Watts mounted to an uninsulated 72
More informationPowers TM Controls SW 141 Differential Static Airflow Switches
Powers TM Controls SW 141 Differential Static Airflow Switches Document No. 155-052P25 SW 1 0518 Description The SW 141 Airflow Switch senses static differential pressure and the diaphragm operated snap
More informationELVORON HR DESIGN AND PLANNING GUIDE
ELVORON HR DESIGN AND PLANNING GUIDE Hydraulic Home Elevator Quality Elevators by Garaventa www.garaventaelevator.com Table of Contents Elvoron HR - Hydraulic Residential Elevator... 2 Technical Reference:...
More informationInstallation Instructions Light Commercial & Irrigation Water Pressure Booster System
Installation Instructions DuraMAC TM Light Commercial & Irrigation Water Pressure Booster System The DuraMAC TM Water Pressure Booster System is the first booster pump of its kind to be designed for virtually
More informationShuttle Type Switches For Moderate to High Liquid Flow Rates
Shuttle Type Switches For Moderate to High Liquid Flow Rates Models for flow rate settings from.5 GPM to 100.0 GPM Rugged housings with port sizes ranging from 3/4 to 3 Efficient flow paths assure low
More informationSPEAKMAN. SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET
SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET DESCRIPTION The SEF-1800-CA Eyesaver faucet combines a gooseneck faucet with
More informationHome Elevator. Planning Guide
Home Elevator Planning Guide Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site preparation or construction. 2 Table of Contents Elvoron Home Elevator...4
More informationMicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves
MicroCoat System Operating Manual MC Series MC785M, MC785M-WF Spray Valves A NORDSON COMPANY Introduction The MicroCoat System provides precise lubrication control for metal stamping operations. The MC
More informationBYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES
BULLETIN 20-5100-68 BYPASS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES BYPASS ROTOMETERS SK bypass Rotameter systems are designed for the accurate measurement of fluid rate of flow in pipelines 11/2
More informationPortable Filter Carts 10MFP with Moduflow
Portable Filter Carts 10MFP with Moduflow Applications for Portable Filter Carts Parker portable filter carts are the ideal way to prefilter and transfer fluids into reservoirs or to clean up existing
More informationDistributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE #
PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Switches Selector Switches SW 786 155-118P25 G-3 Positioning Switch SW 141 155-117P25 G-5 Enthalpy Control Switch EE 141 155-054P25 G-7 Static Pressure
More informationRP-4000 Reserve Power Control
Instruction Manual IM-0580 RP-4000 Reserve Power Control Table of Contents General Information... 2-3 Introduction... 2 Cautions... 2 Receiving/Inspection... 2 Storage... 2 Equipment Return... 2 Identification
More informationAccessories. Section Outline
Fisher Controls offers a line of accessories including filters, needle valves, pressure gauges, vent assemblies, and emergency shutoff valves. This section provides technical information for these accessories.
More informationAC Leak Freeze AIR CONDITIONING. AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems
AC Leak Freeze AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems Will continue to seal additional Leaks for up to 1 year that meet testing specifications Does not contain
More informationMH Modular Divider Valves Product Specs and Ordering. and. Bulletin Revised October 2000
Bulletin 10103 R and MH Modular Divider Valves Product Specs and Ordering Modular, Series- Progressive, Divider Valve Delivers Positive Oil Lubrication for Gas Engines, Compressors and Similar Equipment
More informationIndex. UV-7B Sizing Chart UV-7BC Sizing Chart... 17
Revision: 9-13-13 Index Sales Phone: (888) 577-3326 - Sales Fax: (888) 577-3116 Topic Page Topic Page About EECO.... 3 Warranty Information... 4 Contact Information... 5 Valve Exchange & Rebuild Programs...
More informationCAUTION: The first section of the guide deals with the UP SECTION, while the second deals with the DOWN SECTION.
The information contained herein is for use by skilled hydraulic elevator professionals. Before disassembly of the valve, make sure the power is off by turning the main disconnect switch off and that the
More informationDuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS
DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS The DuraMAC TM Water Pressure Booster System is the first booster pump of its kind to be designed for virtually
More informationOIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100
OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100 The Oil Smart OSS-100 System, when combined with a manual sump pump, will automatically pump water without the risk of pumping oil into the environment. Additionally,
More informationPneumatic Actuator Accessories. Discrete, NEMA 4, Four-Way Air/Air Suffix A2 (For PAD3 & PKD2 actuators)
Air connections to actuator Discrete, NEMA 4, Four-Way Air/Air Suffix A2 (For PAD3 & PKD2 actuators) Integral, NEMA 4, Four-Way Air/Air Suffix A8 (For PKD3, PKD5, PKD7, & PKD9 actuators) Suffix A3 Air
More informationLEAD FREE * LFF113FP. Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology. Materials NOTICE NOTICE ES--LFF113FP
ES--LFFFP Job Name Contractor Job Location Approval Engineer Contractor s P.O. No. Approval Representative LEAD FREE * LFFFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology
More informationElectromechanical Level Control
Electromechanical Level Control Catalog 9034CT9701R2/08 08 Class 9036, 9037, and 9038 and Class 9049 Accessories CONTENTS Description..............................................Page Selection Guide..............................................
More informationPATTERSON PUMP COMPANY
PATTERSON PUMP COMPANY A Gorman Rupp Company JOCKEY PUMP CONTROLLERS UL508 LISTED ETL LISTED FEB 013 Patterson Jockey Pump controllers are built to NEMA industrial standards and are UL508 listed and ETL
More informationDT34 and DT54 Series Rotary Sprinklers
DT34 and DT54 Series Rotary Sprinklers Installation & Service Instructions Introduction The DT34 and DT54 series full-circle rotary sprinklers are designed specifically for golf course applications. Manufactured
More informationMueller 300 Ball Valves Industry-leading 300psi low lead ball valves
Mueller 300 Ball Valves Industry-leading 300psi low lead ball valves Mueller 300 Ball Valves Your assurance of quality, dependable ball valves The ball valve designed for 300 psig working pressure Before
More informationOperation Manual For KITZ B Series Pneumatic Valve Actuators
Operation Manual For KITZ B Series Pneumatic Valve Actuators Thank you for choosing KITZ products. For safe and trouble-free function and performance of the product, ensure to read and understand all items
More informationof wet barrel hydrants, hydrant valves and hydrant tools.
JONES WET BARREL FIRE HYDRANTS The most complete selection of wet barrel hydrants, hydrant valves and hydrant tools. Bronze wet barrel fire hydrants Jones is the leader. With over 100 years of experience
More informationProfessional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS
Model T033 CONVERTIBLE JET PUMP /HP 900 GPH Suction lift Head of 5 (7.5m) in shallow well mode Professional Series YEAR WARRANTY Suction: /4 Discharge: NPT Maximum pressure: 85 PSI US GPH LPH 5 900 3400
More informationSECTION 8 Fire Protection
Bronze Wet Barrel Fire Hydrants With over 100 years of experience on the west coast the heart of the wet barrel market James Jones Company, LLC is the innovator in the bronze wet barrel hydrant industry.
More informationCIRCLE SEAL CONTROLS
CIRCLE SEAL CONTROLS ATKOMATIC SOLENOID VALVES INSTALLATION, MAINTENANCE, AND OPERATION INSTRUCTIONS 13000 SERIES Stainless, Normally Closed, Direct Lift, 3-Way Valve Installation Instructions WARNING:
More informationNECO Pumping Systems
INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems Fuel Oil Transfer System THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED SYSTEM IS OF THE HIGHEST QUALITY AND DESIGN. TO OBTAIN
More informationFLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)
FLOOD PROTECTION SHUT DOWN VALVE ( and smaller) 01/10 2 6 To Floor Drain L X JB11 4 FS99 5 Installed upstream of Reduced Zone Backflow Preventer. Normally Open Valve - Closes when discharge from RPZ Relief
More informationOPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS
OPERATION MANUAL 3 METALLIC PUMP (CLAMPED) PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF80 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models DUCTILE Models 316 S.S. Models A JDA Global Company CAUTIONS - READ
More informationNEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry
NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW preliminary information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. www.usa.siemens.com/controls
More informationMueller Super Centurion 250 Fire Hydrant
Mueller Super Centurion 250 Fire Hydrant Designed for efficient flow and outstanding, long-term reliability Mueller Super Centurion 250 Fire Hydrant...250 psig rating, high flow, dependable performance,
More informationOPERATION AND PARTS MANUAL
OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : TAP- IN KIT 5100-5151 BAYNE MACHINE WORKS, INC. PHONE: (864) 288-3877 910 FORK SHOALS ROAD TOLL FREE: (800) 535-2671 GREENVILLE S.C., 29605 FAX:
More informationElectric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT
Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT SERIES Features Full Port 16 Stainless Steel ball valve LED light gives continuous status indication IP67 weatherproof polyamide
More informationPriming Systems Installation Instructions
Priming Systems Installation Instructions System Components: Single Priming Pump: Single VAP Valve Systems: Control Panel Activated... 2 Auto Prime (Pressure Switch) Activated... 3 Multiple VAP Valve Systems...
More information1/2" AIR DRIVEN DIAPHRAGM PUMP
1/2" DRIVEN DIAPHRAGM PUMP OPERATION AND SERVICE GUIDE O-1225D NOV. 2008 Page 1 of 6 Refer to Bulletin P-605, Parts List P-9151 DRIVEN, DOUBLE DIAPHRAGM PUMP MANUAL Congratulations on purchasing one of
More information