of wet barrel hydrants, hydrant valves and hydrant tools.
|
|
- Charlene Harvey
- 5 years ago
- Views:
Transcription
1 JONES WET BARREL FIRE HYDRANTS The most complete selection of wet barrel hydrants, hydrant valves and hydrant tools.
2 Bronze wet barrel fire hydrants Jones is the leader. With over 100 years of experience on the west coast the heart of the wet barrel market Jones is the innovator in the bronze wet barrel hydrant industry. With our product quality, design engineering and level of customer service, Jones is renowned as the manufacturer of the world s finest bronze wet barrel fire hydrants. Ideal for moderate climates, our wet barrel hydrants are reliable, easy to use and aesthetically pleasing. Features: Meet requirements of AWWA-C503. All-bronze hydrant heads and spools cast as separate parts. O-ring gasket provides a positive seal at joint of spool and hydrant head. Each nozzle operates independently. Limited number of internal parts. Quick activation of stem movement. Heavy-duty disc holder rotates independently on stem to avoid valve wear, ease operation. Hydrostatically tested at 400 psig. Low-zinc silicon bronze stem. Choice of fluted or straight spool. Two O-ring seals on stem insert. Hydrants available with field-replaceable nozzles. Removable outlet threads for easy access to disc holder and stem. Bronze and cast iron hydrants have interchangeable parts. Clean aesthetic lines. Our J3700 Series includes a style for any application. The number of options and combinations provides just about any configuration of bronze wet barrel fire hydrant needed. Heads are available separately, or in combination with a choice of fluted or straight spools in 6- or 8-bolt patterns. Two-way and three-way hydrants allow many different combinations of 2-1/2 firehose and 4 or 4-1/2 steamer nozzles. Domed, threaded tops available. Plastic or bronze nozzle caps. Non-kinking chains. Refer to our catalog or visit us on the web at for the full selection of J3700 Series wet barrel fire hydrants.
3 Jones fire hydrant valving offers superior features. In wet barrel hydrants, valving makes the big difference in quality. Jones hydrants are the standard of the industry. C D B E H I G A F J A Heavy-duty silicon bronze blow-out proof stem provides long life and corrosion resistance. All stems are polished to provide smooth operation. H Caps are available in plastic, bronze or iron with 1-1/8, 1-1/2 or 1-3/4 operating nuts. All caps are drilled to prevent water pressure build-up. B C One of the industry s largest volume rubber seats and extra-wide contact area provide long-term service, even after minor damage from debris. Models with removable bronze nozzles, makes servicing quick and easy. I J Rubber gasket prevents caps from seizing to the nozzle. Pentagon operation nuts, available in 1-1/8, 1-1/2 or 1-3/4 sizes. D O-ring design assures seal without leakage and easy installation. E Disc holder assembly has a stainless steel set screw to prevent separation from stem. The rubber seat is permanently pinned in place for a tamper-proof assembly. F Dual Buna-N O-rings provide both smooth operation and leak-free stem seal. G Disc retaining nut is pinned for tamperresistant security.
4 Iron fire hydrants performance you can trust. With Jones, all the proven internal performance features you have come to know in our bronze hydrant are transferred to an iron body through the use of interchangeable parts, reducing the need for large parts inventories. This dependable hydrant offers excellent flow characteristics and serviceability. And the weight of the Jones iron hydrant does not require a lifting device. Jones Iron Residential Hydrant The first UL listed and FM approved two-way wet barrel hydrant. Jones Iron Commercial Hydrant The larger, three-outlet UL/FM commercial hydrant offers the same features as the residential hydrant. Residential 2-way hydrant 2-1/2" x 4-1/2" Commercial 3-way hydrant 2-1/2" x 2-1/2" x 4-1/2"* *Also available as 2-1/2" x 4-1/2" x 4-1/2" Detect damage and halt water flow loss TM with the Jones Tell-Tail Break-off Hydrant The Tell-Tail Break-off Hydrant is a unique wet barrel hydrant innovation. When a wet barrel hydrant is hit and broken off, the Tell-Tail check valve completely shuts, preventing the loss of water and water pressure. In addition, it provides a visible tell-tail low-volume stream of water to indicate that the hydrant has been damaged, yet does not present a serious loss of water or cause damage. Additional features: Minimizes water hammer. Smooth flow characteristics minimize pressure loss. Heavy bronze check valve construction. Easy-to-reset design (no springs). Easy to extend for grading adjustments. Adapts to all current and past Jones hydrant designs. Ductile iron, bronze and stainless steel construction.
5 Jones hydrant options and tools Auxiliary valve options allow versatile hydrant usage. fire plug valves angle fire plug valves extension nipple high pressure, angle fire plug valves Hydrant wrenches a type for every need. one pentagon hole for 1-1/2, 2, 2-1/2 couplings four pentagon holes for 2-1/2 coupling five pentagon holes for 2-1/2 coupling adjustable, with brass-plated steel handle Plastic hose caps tapered with drilled hole tapered with chain ring tapered with chain ring and chain Here s how the Jones TM Tell-Tail Break-off Hydrant works: 1 When the hydrant is hit, 2 Hydrant and adapter 3 the safety flange breaks, plate are released from releasing hydrant from lower barrel, and check check valve. valve begins to close. Valve shuts completely and, working with water pressure, stays closed. Through-hole in operating rod minimizes water hammer while providing a visual notification of damage.
6 Decatur, Illinois All products must be installed and maintained in accordance with applicable instructions and/or standards. Form /07-5M-1 Copyright 2007 Jones Company, Division Mueller Water Products, Inc. Printed in U.S.A.
SECTION 8 Fire Protection
Bronze Wet Barrel Fire Hydrants With over 100 years of experience on the west coast the heart of the wet barrel market James Jones Company, LLC is the innovator in the bronze wet barrel hydrant industry.
More informationFIRE HYDRANTS. Wet Barrel Fire Hydrants
FIRE HYDRANTS Wet Barrel Fire Hydrants Jones Wet Barrel Fire Hydrants With over 100 years of experience on the west coast the heart of the wet barrel market James Jones Company is the innovator in the
More informationMueller Super Centurion 250 Fire Hydrant
Mueller Super Centurion 250 Fire Hydrant Designed for efficient flow and outstanding, long-term reliability Mueller Super Centurion 250 Fire Hydrant...250 psig rating, high flow, dependable performance,
More informationGENERAL FEATURES / SPEC M&H AWWA C502 FIRE HYDRANTS Style 929 Traffic Model 250 PSI Working Pressure 500 PSI Hydrostatic Test AWWA UL / FM Approval Type: Compression type, opening against line pressure.
More informationTriton. Wet Barrel Ductile Iron. Fire Hydrants. Reliable Connections. operation / Maintenance manual. Inspection and Installation 2
operation / Maintenance manual MUELLER TAble of contents PAGE Triton Inspection and Installation 2 Installation and Testing 3 Wet Barrel Ductile Iron Maintenance Instructions 4 Parts 5 Notes 6-7 Fire Hydrants
More informationMUELLER Super Centurion fire hydrants
MUELLER Super Centurion fire hydrants MUELLER SUPER CENTURION FIRE HYDRANT Since its introduction in 1976, millions of Centurion fire hydrants have been installed throughout the world. There are a number
More informationSuper Centurion Hydrants Designed for efficient flow and outstanding, long-term reliability
Super Centurion Hydrants Designed for efficient flow and outstanding, long-term reliability Mueller Super Centurion Fire Hydrants High flow and dependable long time performance. 1 Hold-down nut Features
More informationFIRE PROTECTION PRODUCTS
SUPER CENTURION FIRE HYDRANT Mueller Super Centurion Fire Hydrant Since its introduction in 1976, millions of Centurion fire hydrants have been installed throughout North America. There are a number of
More informationCLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION
CLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION TESTING AND DESIGN SPECIFICATIONS (PER AWWA C502 / NSF /ULC & FM) 1. Hydrant shall be manufactured in accordance with AWWA C502 latest revision
More information5 1 /4 PACER. It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT AMERICAN FLOW CONTROL WATEROUS FIRE HYDRANT
WATEROUS FIRE HYDRANT DUCTILE IRON 250 P.S.I.G. WATEROUS FIRE HYDRANT AMERICAN FLOW CONTROL It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT CONSTRUCTION WATEROUS FIRE HYDRANT TWO PIECE OPERATING
More informationSentinel 250 Fire Hydrant
Maintenance Instructions manual table of contents PAGE Sentinel 250 Fire Hydrant Inspection and Lubrication 2 Rotating Hydrant to Face Desired Direction 3 Installing Extension Section 3-6 Restoring Service
More informationmh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY
mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY 129 HYDRANT YESTERDAY, TODAY, & TOMORROW For more than 85 years, the M&H
More informationK81-D FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS
GUARDIAN K81-D FIRE HYDRANT CERTIFICATIONS ISO 9001 ISO 14001 BS OHSAS 18001 AWWA C502 NSF 61 140 YEARS WWW.KENNEDYVALVE.COM C For Generations COMPONENTS AND FEATURES A B C E D F G H J L M K N P Q S R
More informationSeptember 2012 / M&H C502 / Model 129
GENERAL FEATURES / GENERAL SPEC M&H AWWA C502 FIRE HYDRANTS Model 129 Traffic Model 250 PSI Working Pressure 500 PSI Hydrostatic Test AWWA UL / FM Approved Type: Compression type, opening against line
More informationK81-DD FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS
GUARDIAN K81-DD FIRE HYDRANT CERTIFICATIONS ISO 9001 ISO 14001 BS OHSAS 18001 AWWA C502 NSF 61 140 YEARS WWW.KENNEDYVALVE.COM C For Generations COMPONENTS AND FEATURES A B C E D F G H J K M L N P Q S R
More informationSentinel 250 Fire Hydrant. Solid design and features to meet any municipal requirement.
Sentinel 250 Fire Hydrant Solid design and features to meet any municipal requirement. Product Features That meet any municipal requirement. 1 Operating Nut Shields the hold down nut from tampering and
More informationBALL VALVES. Industry-Leading 300psi Low Lead Ball Valves
BALL VALVES Industry-Leading 300psi Low Lead Ball Valves Designed and Manufactured to Meet Your Needs 1 Lockwing Accepts bullet lock (when equipped on meter valve). 2 Stainless steel reinforced seat gaskets
More informationAVK SAUDI VALVES MANUFACTURING COMPANY
AVK SAUDI VALVES MANUFACTURING COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION
More informationRev. 2/16 MUELLER Fire Hydrant Reference Manual Mueller Co. Printed in the U.S.A.
Rev. 2/16 MUELLER Fire Hydrant Reference Manual 2016 Mueller Co. Printed in the U.S.A. Index 1 Fire Hydrant Reference Material Index Index...1 Identification...2-36 Dry Barrel Hydrants - AWWA...3-21 Dry
More informationBUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE STYLE Consult factory for sizes
An industry leader in underground and in-plant applications. BUTTERFLY VALVES STYLE 4500 3 24 STYLE 1450 30 54 Consult factory for sizes 60 120 C504 Class 150B & 250B M&H Valve is a division of McWane,
More informationMueller 300 Ball Valves Industry-leading 300psi low lead ball valves
Mueller 300 Ball Valves Industry-leading 300psi low lead ball valves Mueller 300 Ball Valves Your assurance of quality, dependable ball valves The ball valve designed for 300 psig working pressure Before
More informationAmerican Flow control 5 1/4 b-84-b-5
American Flow control 5 1/4 b-84-b-5 Fire Hydrant FLOW CONTROL Construction Fully complies with AWWA C502 and is available UL Listed and FM Approved in applicable configurations. one-piece bronze OPERATING
More informationAmerican Flow control 5 1/4 B-62-B-5
American Flow control 5 1/4 B-62-B-5 Fire Hydrant FLOW CONTROL Construction Fully complies with AWWA C502 and is available UL Listed and FM Approved in applicable configurations. one-piece bronze OPERATING
More informationMUELLER Hydrant Security Device
MUELLER HYDRANT DEFENDER SECURITY DEVICE 9A. Rev. 8-04 When conducting a vulnerability assessment (V.A.), infiltration of a municipal water supply through an unsecured fire hydrant should be a primary
More informationvisit us online at
PRICE SHEET (PL-1014-VLV Replaces PL-0513-VLV) TABLE OF CONTENTS VALVES & HYDRANTS Page(s) Product Line Price Sheet 1 AWWA C515 Gate Valves NRS Series 2010 & 1010 PL-1014 Multiplier 2 AWWA C515 Gate Valves
More informationModel descriptions. 2. For other pressure and temperature limits, consult ANSI B16 cast iron flange standards.
VALVES & CONTROLS KUNKLE SAFETY AND RELIEF PRODUCTS Cast Iron Liquid Relief Valves Model 228 Model descriptions Model 91: Bronze trim, with pressure-tight cap. Suitable for maximum back pressure of 60
More informationAccording to AWWA-standard
According to -standard Water Fire fighting - UL/FM 304 Gate valves - Cast iron 320 Gate valves OS&Y 306 Service connection valves 322 Post indicators 306 Combi valves 307 Gate valves - 310 Gate valves
More informationData Sheet Issue A
General Description The Rapidrop Fig 601/602 dry barrel post / flushing fire hydrant is designed to be a trouble free, easy to maintain hydrant. The Fig 601/602 fire hydrant is rated for a working pressure
More informationAMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT
AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available UL Listed and Approved by FM Approvals in applicable configurations. DUCTILE IRON
More informationAMERICAN FLOW CONTROL 5 1/4 B-84-B-5 FIRE HYDRANT
AMERICAN FLOW CONTROL 5 1/4 B-84-B-5 FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available Listed by Underwriters Laboratories, Inc. and Approved by FM Approvals in applicable configurations.
More informationPROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA
The following standard specification is intended to be edited according to the specifics of the project. Brackets [ ] and areas shaded in gray [e.g. format] indicate requirements that are optional depending
More informationTABLE OF CONTENTS. 3 Outlet Stainless Steel Body. 3 Outlet Ductile Body. 2 Outlet Ductile Body 2 Outlet Bronze Body
AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING AND STORAGE INSTALLATION
More informationAMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS
AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING AND
More informationAMERICAN FLOW CONTROL 5 1/4 B-62-B-5 FIRE HYDRANT
AMERICAN FLOW CONTROL 5 1/4 B-62-B-5 FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available UL Listed and Approved by FM Approvals in applicable configurations. ONE-PIECE BRONZE
More informationCast Iron Liquid Relief Valves
Cast Iron Liquid Relief Valves Features Bolted bonnet permits easy inspection and servicing without removal from system. Quality cast iron body and bonnet, insert and disc are available in either bronze
More informationFIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description
FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL Item No.s/Description Item No. Description Material Specification HYDRANT Qty. Req d Item No. Description Material Specification 1 Operating
More informationECCENTRIC PLUG VALVES
Serving the Water & Waste Water Industry Since 1878 ECCENTRIC PLUG VALVES C517 3 24 sizes available Multiple end connections available M&H Valve is a division of McWane, Inc. www.mh-valve.com AVAILABLE
More informationADMIRAL HYDRANT. clowvalve.com
clowvalve.com ADMIRAL HYDRANT AWWA C502 UL LISTED FM APPROVED NSF 61/372 CERTIFIED 250 PSI WORKING PRESSURE 350 PSI WORKING PRESSURE AVAILABLE 10-YEAR LIMITED WARRANTY Clow Valve, A Division of McWane,
More informationAMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT
AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available Listed by Underwriters Laboratories Inc. and Approved by FM Approvals in applicable
More informationOPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT
OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT INDEX 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE REPAIRS Operation
More information5 1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT BY AMERICAN FLOW CONTROL
5 1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT BY AMERICAN FLOW CONTROL CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available UL Listed and FM Approved in applicable configurations. ONE-PIECE
More informationOPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT
OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT INDEX 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE REPAIRS Operation
More informationWater Distribution Solutions
Water Distribution Solutions Table of Contents WaterMaster 5CD250 Fire Hydrants 6 WaterMaster 5BR250 Fire Hydrants 8 FlowMaster Resilient Wedge Gate Valves 11 Valve Boxes 17 Meter Boxes 22 Table of Contents
More information2-6 FIRE HYDRANT---(MODEL ½ & 5 ¼
M&H PDF PAGE INDEX Page PRODUCT 2-6 FIRE HYDRANT---(MODEL 129 4 ½ & 5 ¼ ) 7 How to Order Fire Hydrants 8 FIRE HYDRANT WARRANTY 9-13 FIRE HYDRANT---(MODEL 929 5 ¼ ) 14-18 FIRE HYDRANT---(POST HYDRANT 2
More informationAWWA SWING CHECK VALVES. Engineering Creative Solutions for Fluid Systems Since 1901
AWWA SWING CHECK VALVES Engineering Creative Solutions for Fluid Systems Since 1901 TABLE OF CONTENTS AWWA SWING CHECK VALVE Series 8001 Lever & Weight or Spring...1 Series 9001 Lever & Weight or Spring...2
More informationService Materials. Service Materials. With Three Locations to Serve You: Avoca, NY 8125 Kanona Rd. Avoca, NY (607)
Service Materials Service Materials Rochester, NY 785 Beahan Rd. Rochester, NY 14624 (585) 436-9624 With Three Locations to Serve You: Avoca, NY 8125 Kanona Rd. Avoca, NY 14809 (607) 566-2214 Watertown,
More informationSOLENOID CONTROL VALVE
PROJECT NAME LOCATION SOLENOID CONTROL VALVE INTRODUCTION This specification covers the design, manufacture, and testing of 4 in. (100 mm) through 36 in. (900 mm) Control Valves PART 1 - GENERAL 1. Standard
More informationMUELLER. Super Centurion 350 Fire Hydrant. Reliable Connections. Inspection and Maintenance 2. Filling Oil Reservoir 3. Facing the Hydrant 4
operating Instructions manual MUELLER Super Centurion 350 Fire Hydrant table of contents PAGE Inspection and Maintenance 2 Filling Oil Reservoir 3 Facing the Hydrant 4 Restoring Service after Traffic Knockover
More informationKunkle Models 91/218/228 liquid relief valves Safety and relief products
Cast iron liquid relief valves with bronze trim including models UL and FM approved for fire pump installations Model 228 Features Bolted bonnet allows easy inspection and servicing without removal from
More informationKunkle Models 91/218/228 liquid relief valves Safety and relief products
Cast iron liquid relief valves with bronze trim including models UL and FM approved for fire pump installations Model 8 Features Bolted bonnet allows easy inspection and servicing without removal from
More informationWater Distribution Solutions
Water Distribution Solutions Table of Contents WaterMaster 5CD250 Fire Hydrants 6 WaterMaster 5BR250 Fire Hydrants 8 FlowMaster Resilient Wedge Gate Valves 11 Valve Boxes 17 Meter Boxes 22 Table of Contents
More informationMEDALLION HYDRANT. clowvalve.com AWWA C502 UL LISTED FM APPROVED NSF 61/372 CERTIFIED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY
clowvalve.com MEDALLION HYDRANT AWWA C50 UL LISTED FM APPROVED NSF 6/37 CERTIFIED 50 PSI WORKING PRESSURE 0-YEAR LIMITED WARRANTY Clow Valve, A Division of McWane, Inc. MEDALLION HYDRANT FIRE PROTECTION
More informationFord Brass Saddles Style 101B and 202B
101B Ford Brass Saddles 101B and 202B 101B, 3/4" and 1" Taps 202B, 3/4" through 2" Taps Specifications Body - 85-5-5-5 brass alloy as per ASTM B62, ASTM B584 and AW WA C800. Threads may be FIP, AW WA,
More informationMILLCENTRIC FULL/100% POR T ECCENTRIC PLUG VALVE
ISO 9001 CERTIFIED MILLCENTRIC FULL/100% POR T ECCENTRIC PLUG VALVE Suggested Specifications The Milliken criteria of quality, reliability, safety and value are embodied in the Millcentric Eccentric valve,
More informationAWWA, RESILIENT WEDGE GATE VALVES
Type AVK Ref. # Size Weight kg lb US $ Series 04 Wrench nut Ductile Iron Series 08 Handwheel for AVK gate valves series 45, 55, 65 and 66 With bolt and washer Grey cast iron Size 1"-30" Series 18/45/55/65/66
More informationSECTION VIII. (Sub-section 430) Wastewater Valves and Appurtenances. 1. General thru Gate Valves thru 430-3
SECTION VIII (Sub-section 430) Wastewater Valves and Appurtenances Article Page 1. General 430-1 thru 430-2 2. Gate Valves 430-2 thru 430-3 3. Plug Valves 430-3 thru 430-4 4. Check Valves 430-4 5. Tapping
More information720G Wafer and 821G Globe Style Silent Check Valves
OPERATION/MAINTENANCE MANUAL 70G Wafer and 1G Globe Style Silent Check Valves TABLE OF CONTENTS PAGE General Information / Installation Installation / Operation Troubleshooting / Assembly 4 Parts Information
More informationApproved Branded Traceable Fire Protection & Waterworks Valves
Approved Branded Traceable Fire Protection & Waterworks Valves (800) 766-0076 www.smithcooper.com Los Angeles, CA Atlanta, GA Vancouver, WA Chicago, IL AWWA C515 Compliant CONSIDER Your Options Tamper
More informationTransportation Products
Transportation Products Butterfly Valves Hopper Tees Actuators Accessories A Name You ve Trusted for Years... Resilient Seated Butterfly Valves 400 & 480 Series 1 Piece Body Design This economical, resilient
More informationVALVES, FIRE HYDRANTS, AND APPURTENANCES
VALVES, FIRE HYDRANTS, AND APPURTENANCES PART 1 - GENERAL 1.01 SECTION INCLUDES A. Butterfly Valves B. Gate Valves C. Tapping Valve Assemblies D. Fire Hydrant Assemblies E. Flushing Devices (Blowoffs)
More informationHD Series. Pilot-Operated Regulating Valves. HD Series features & benefits
Watson McDaniel reserves the right to change the designs and/or materials of its products out notice. 2004 Watson McDaniel Company features & benefits Ductile Iron body for higher pressures Full port strainer
More informationPIN VICES 02 2 DRILL 02 9 CUTTING BROACHES SMOOTHING BROACHES 02 13
02 PIN VICES 02 2 DRILL 02 9 CUTTING BROACHES 02 10 SMOOTHING BROACHES 02 13 PIN VICES i Pin vices are used to firmly hold items such as winding stems, cutting and smoothing broaches, drills, taps, wires,
More informationSuggested Specifications
ISO 9001 Certified Suggested Specifications The Milliken criteria of quality, reliability, safety and value are embodied in the Millcentric Eccentric valve, setting higher standards for dependable performance
More informationmh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY
mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY 129 HYDRANT YESTERDAY, TODAY, & TOMORROW For more than 85 years, the M&H
More informationAWWA Swing Check Valves
AWWA Swing Check Valves Engineering Creative Solutions for Fluid Systems Since 1901 A Tradition of Excellence With the development of the first rubber seated butterfly valve more than 70 years ago, the
More informationFIRE HYDRANT SPECIFICATION CHANGE SUBMITTAL
FIRE HYDRANT SPECIFICATION CHANGE SUBMITTAL PACKAGE CONTENT 1. Reason for Change 2. Features and Benefits Provided 3. Specification Text 4. Specification Diagram JUSTIFICATION FOR FIRE HYDRANT SPECIFICATION
More informationCOMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE
PROJECT NAME LOCATION COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES INTRODUCTION This specification covers the design, manufacture, and testing of 1 in. (25 mm) through 36 in. (900
More information516509_tabs 11/16/10 4:55 AM Page 1 FIRE HYDRANTS
Date Printed: November 2010 FIRE HYDRANTS or Tyton (6"),6, or 8" A EDDY FIRE HYDRANTS PARTS LIST WORKING PRESSURE: 150 PSI Note: Discontinued For Reference Only 350 PSI Working Pressure
More informationKunkle Models 189/363/389 safety valves Safety and relief products
Heavy duty ASME Section VIII, air/gas cryogenic, UV, National Board certified safety valves Model 189 Features Heavy duty construction provides long service life. Unique three-piece disc assembly with
More informationSweetwater Authority Fire Hydrant Maintenance Program Standards and Procedures
Introduction Fire hydrants constitute a critical component providing fire protection for the City of National City, Chula Vista and the County of San Diego. In case of emergencies fire hydrants must be
More informationINDEX WATEROUS 5 1/4 IN. PACER FIRE HYDRANT
INDEX WATEROUS 5 1/4 IN. PACER FIRE HYDRANT PAGE INTRODUCTION AND HISTORY............................................................. 2B 2 ORDERING Dimensions: Overall Hydrant...............................................................
More informationCCNE Check Valves Engineering Creative Solutions for Fluid Systems Since 1901
CCNE Check Valves Engineering Creative Solutions for Fluid Systems Since 1901 A Tradition of Excellence With the development of the first rubber seated butterfly valve more than 70 years ago, the Henry
More informationBallcentric Plug Valve
Ballcentric Plug Engineering Creative Solutions for Fluid Systems Since 1901 A Tradition of Excellence With the development of the first rubber seated butterfly valve more than 70 years ago, the Henry
More informationPRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE
PROJECT NAME LOCATION PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE INTRODUCTION This specification covers the design, manufacture, and testing of 2-1/2 in. (65 mm) through 18 in. (450 mm) Control
More informationHydrant Security. Taking that first step. A White Paper Published by. Chattanooga, TN 37450
Hydrant Security Taking that first step A White Paper Published by Chattanooga, TN 37450 Form 12714 Rev. 7/11 Copyright - Mueller Co., Chattanooga, TN - April 2011 Hydrant Security Taking that First Step
More informationFLOAT CONTROL VALVES
PROJECT NAME LOCATION FLOAT CONTROL VALVES INTRODUCTION This specification covers the design, manufacture, and testing of 8 in. (200 mm) through 36 in. (900 mm) Control Valves PART 1 - GENERAL 1. Standard
More informationPRESSURE REDUCING CONTROL VALVES
PROJECT NAME LOCATION PRESSURE REDUCING CONTROL VALVES INTRODUCTION This specification covers the design, manufacture, and testing of 1 in. (25 mm) through 36 in. (900 mm) Control Valves PART 1 - GENERAL
More informationSAN ANTONIO WATER SYSTEM SPECIFICATIONS FOR RUBBER-SEATED BUTTERFLY VALVES 3 INCHES THROUGH 72 INCHES ANSI/AWWA C504 Class 150/250 December 2012
SAN ANTONIO WATER SYSTEM SPECIFICATIONS FOR RUBBER-SEATED BUTTERFLY VALVES 3 INCHES THROUGH 72 INCHES ANSI/AWWA C504 Class December 2012 1. SCOPE This product specification covers class rubber-seated butterfly
More information740G Double Disc Check Valve
OPERATION/MAINTENANCE MANUAL 740G Double Disc Check Valve TABLE OF CONTENTS PAGE General Information 2 Installation / Operation 3 Troubleshooting / Assembly 4 Parts Information 5 WARNING: 1. Read all applicable
More informationIndustrial Bronze and Iron Price List
Industrial Bronze and Iron Price List TABLE OF CONTENTS IBI-1017 Effective: October 2, 2017 Revised: 12/07/2017 Suggested list prices are subject to change without notification. Visit our Website for the
More informationAMERICAN FLOW CONTROL 3-16 SERIES 2100 RESILIENT SEATED CHECK VALVE
AMERICAN FLOW CONTROL 3-16 SERIES 2100 RESILIENT SEATED CHECK VALVE CONSTRUCTION STAINLESS STEEL PIPE PLUG Allows installation of pressure gauge. STAINLESS STEEL FASTENERS Helps provide corrosion resistance.
More informationThe PL Series Pressure Air Release Valves. Sizes 1 thru 6 Available Compound Lever System Adjustable Buna-N Rubber Plunger. Crispin.
The PL Series Sizes 1 thru 6 Available Compound Lever System Adjustable Buna-N Rubber Plunger Crispin Since 1905 PL SERIES Functio n Allows air and/or gas to be released from a pressurized liquid system
More informationPNEUMATIC SLIDING VALVE
INSTALLATION, OPERATION, & #: MM-SV001 6-23-09 Rev. A Page 1 of 8 PNEUMATIC SLIDING VALVE PART NUMBERS (Including, but not inclusive) SV704MSTS, SV714MSTS, SV754MSTS, SV764MSTS, SV774MSTS, SV706MSTS, SV716MSTS,
More informationSlide Gate Hydrant Maintenance Manual
Slide Gate Maintenance Manual Terminal City Iron Wks Ltd. Unit#3 99 19th Street, Langley, BC V1M 3C This Maintenance Manual is intended to give a guide to Maintenance. The Manual covers: Maintenance and
More informationDIMENSIONS (approximate)
Page 1 of 8 a NRS GATES OS&Y GATES company Model 48 Resilient Wedge Gate Valve SPECIFICATION SUBMITTAL SHEET FEATURES Sizes: 2 1/2" 3" 4" 6" 8" 10" 12" Maximum working water pressure 200 PSI Maximum working
More informationTHE GLOBAL LEADER IN PIPE PLUG & TESTING
THE GLOBAL LEADER IN PIPE PLUG & TESTING PNEUMATIC PLUGS MECHANICAL PLUGS GAUGES TOOLS & ACCESSORIES TESTING EQUIPMENT 2 Oatey.com/Cherne TEST WITH THE BEST CHERNE TABLE OF CONTENTS PNEUMATIC PLUGS BLOCKING
More informationLocktite Manual Reset Gas Shut-Off Valves
Instruction Manual 750, 10/25/04 Locktite Manual Reset Gas Shut-Off Valves Series 200 LT Eclipse 200 LT valves are manually opening valves that automatically shut off the gas supply to a combustion system
More informationPRESSURE RELIEF / SUSTAINING CONTROL VALVES
PROJECT NAME LOCATION PRESSURE RELIEF / SUSTAINING CONTROL VALVES INTRODUCTION This specification covers the design, manufacture, and testing of 1 in. (25 mm) through 36 in. (900 mm) Control Valves PART
More informationSECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING
PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. Provide labor, materials, equipment, and services necessary to install valves required to complete the work indicated on drawings. B. ASME Compliance: 1. ASME
More informationMUELLER. Centurion Series Fire Hydrant. Centurion Super Centurion 200 Super Centurion 250. Reliable Connections. Background and Forward 2
operating Instructions manual MUELLER table of contents PAGE Background and Forward 2 Centurion Series Fire Hydrant Centurion Super Centurion 200 Super Centurion 250 Handling and Inspection 3 Installation
More informationSECTION VALVES
PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Specification Sections, apply to this Section. B. Related Sections:
More informationPRODUCT MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT
PRODUCT MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT INDEX 5-1/4 AMERICAN - DARLING B-84-B-5 FIRE HYDRANT INTRODUCTION AND HISTORY... 1B-2 ORDERING Dimensions: Overall Hydrant... 1B-3 Optional Bases...1B-4
More informationSECTION VALVES PART 1 -GENERAL
SECTION 1571 0 VALVES PART 3- EXECUTION General Shut-off Valves Balancing Valves Drain Valves RELATED WORK Section 15430- Plumbing Specialties Section 15450- Plumbing Equipment PART 1 -GENERAL SCOPE This
More informationPressure Relief Valve Maintenance Manual
Technical Manual 1098T Pressure Relief Valve Maintenance Manual Farris Engineering Division of Curtiss-Wright Flow Control Corporation TABLE OF CONTENTS - Manual Revision 0 Introduction & Safety Tips...
More informationK81 Guardian Fire Hydrants. Operation & Maintenance Guide
Kennedy Valve K81 Guardian Fire Hydrants Operation & Maintenance Guide Installation 1. When hydrants are received from manufacturer they should be handled carefully to avoid breakage and damage to flanges.
More information1. Valves shall conform to the latest version of AWWA Standard C-509 covering Resilient Seated gate Valves for Water Supply Service.
KENNEDY KENNEDY VALVE MODEL VALVE KS-RW 1. Valves shall conform to the latest version of AWWA Standard C-509 covering Resilient Seated gate Valves for Water Supply Service. 2. The valves shall have a cast
More informationAir Compressor Pumps. Best Pump Warranty In The Industry. Single Stage Cast Iron Compressor. Two Stage Cast Iron. Compressor C B
106 South Lake Court, Lexington, SC 29073 Tel: 803-356-4777 Fax: 803-356-4737 Air Compressor Pumps Best Pump Warranty In The Industry The Mi-T-M Pump Exchange Program provides pump replacement for the
More informationLineseal Butterfly Valves 150B, 250B, & 350B Class; Sizes 3-48
Lineseal Butterfly Valves 0B, 0B, & 0B Class; Sizes -8 Mueller Lineseal Butterfly Valves Sizes -8 Performance is key. Designed specifically for the waterworks industry, Lineseal butterfly valves offer
More informationKENNEDY VALVE GENERAL SWING CHECK VALVES OPERATION & MAINTENANCE MANUAL
GENERAL SWING CHECK VALVES OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS 3 General 3 Receipt & Inspection 4 Check Valve Storage & Handling 4 7 Selection 8 9 Installation 10 Service Limitations 11 17
More informationISO RESILIENT WEDGE GATE VALVE. Engineering Creative Solutions for Fluid Systems Since 1901
ISO RESILIENT WEDGE GATE VALVE Engineering Creative Solutions for Fluid Systems Since 1901 TABLE OF CONTENTS ISO RESILIENT WEDGE GATE VALVE Scope of Line...1 Features and Benefits...1 Suggested Specification...2
More information