UniMag DS Series Magnetic Flowtubes

Size: px
Start display at page:

Download "UniMag DS Series Magnetic Flowtubes"

Transcription

1 EMCO UniMag TM Magnetic Flowmeters UniMag DS Series Magnetic Flowtubes The UniMag Magnetic Flowmeter System consists of the patented UniMag Flowtube and the 4411e Transmitter. UniMag Magnetic Flowmeters are a more cost effective solution for many applications compared to conventional mag technology, because they improve on-site measurement performance and decrease costs associated with maintenance and downtime. DS Series UniMags use only one UniMag sensor, which lowers the product cost by approximately 25% in sizes 16 in. (400 mm) and smaller. The UniMag is approved as standard by Entela to UL and CSA compliance for safety in ordinary locations, to NEC and CSA standards for Class 1, Div. 2, Groups C, D, T4 and ATEX Zone 2 explosive atmospheres. UNIMAG DS SERIES FEATURE Totally encapsulated sensor components Option for linerless flowtube construction Patented 4411e AC coil excitation (high coil current & high pulsation frequency) Large conical electrodes, high signal strength Field replaceable sensor with optional 5 year warranty Sensor reference coil Internal grounding electrode Flowtubes manufactured to any length Patents , , , , BENEFIT Highly insensitive to pipeline vibration, shock, and microporosity Lower initial cost; Options suitable for full vacuum. Eliminates errors due to liner microporosity. Eliminates the need for liner protectors. Time constant of 0.03 seconds for batching and stable process control; High signal-to-noise ratio for immunity to media noise (e.g. pulp stock and mining slurries); Accuracy unaffected by electrode coatings such as sewage grease, calcium carbonate, algae or similar. Low conductivity media > 0.08 µs/cm Suitable for fluids that coat piping surfaces (e.g. black liquor, raw sewage, etc.) Minimizes downtime due to failures and reduces stocking costs (associated with spare parts) Output compensated for effects due to magnetic particles (slurries) and ambient/process temperature shifts Installation in non-conductive or lined pipe without grounding rings or external straps Meets ISO/DIS for many sizes; Simplifies installation (no spacers or alteration) 2006

2 Not Just Another Magmeter INNOVATIVE SENSOR TECHNOLOGY materials such as stainless steel, PVC and HDPE are available. The UniMag Sensor is fitted into the flowtube via a standpipe. The sensor includes an exciter coil and a reference coil, and is available in various electrically insulative materials. Two conical measurement electrodes and one grounding electrode protrude through the insulative material, which also insulates the electrodes from the piping. All internal sensor components and wiring are encapsulated using Each UniMag sensor is as a complete solid state insulated magmeter. Consequently, unlike other magmeters, there is no need for further insulation by way of a liner. With UniMag a liner is only necessary to protect the flowtube from extremely abrasive or highly corrosive media. With UniMag errors due to liner microporosity or liner damage do not exist. a solid setting insulator material. The sensor is normally installed on DS series flowtubes up to 16 (450 mm). It is ready wired and conduited to a junction box installed on the flowtube. The cables to and in the junction box are potted with a re-enterable gel. The complete assembly is indefinitely submersible to NEMA 6 and IP68 to 30 feet (10 m) water column. The measurement electrodes are removable on sensors of various sizes. The sensor electrodes are normally large, with conical ends in the media. While conical ends help keep the electrodes clean, reliance is not made on that. Furthermore, highly abrasive media will quickly wear the conical ends flat, without affecting accuracy. For all media, reliance on a highly reliable, good quality signal is placed on the uniquely high signal strength and high exciter frequency. A patented high ratio exists between the distance apart of the electrodes and the flowtube diameter, such that the magnetic field is well distributed over the entire flowtube cross section. These combined effects, together with a uniquely powerful field strength, provide a truly weighted Sensor with Standard Electrodes velocity signal, highly insensitive to velocity profile distortion. As a result, the UniMag DS requires typically only 10 diameters of straight pipe upstream and 5 downstream, or less. For lesser straight length requirements the multisensor UniMag DT series is used. Each sensor uniquely incorporates a reference coil, quite separately from the exciter coil. The reference coil measures magnetic fields in the media, and compensates for it. For media containing magnetite, consult EMCO. LINED OR UNLINED UNIMAG FLOWTUBES The most cost effective UniMag DS flowtube material is Sensor with Optional Extended Conical Electrodes carbon steel, which may be suitably coated with fusion bonded protective finishes, inside and outside. Other

3 Not Just Another Magmeter BASIC UNIMAG SENSOR CONCEPTS There are four basic UniMag concepts to cost effectively cover all media types: 1) Sensors with standard conical electrodes, with fusion bonded epoxy or polyurethane protected metal flowtubes or PVC, HDPE flowtubes: used for water, sewage and similar applications. 2) As 1) above, except with extended conical electrodes: Used when media coats the flowtube thick enough to cover standard conical electrodes. The electrodes are then specially made long enough to protrude the media coating. Standpipe Wall Heavy Duty Polyurethane Flowtube Heavy Duty Polyurethane Sensor with Extra-Long Electrodes Note: Wear rate of liner = wear rate of electrodes Pipe Wall Flowtube with Fusion Bonded Liner or No Coating 3) Concave sensors with flat electrodes, no internal flowtube coating, externally fusion bonded flowtubes: Used for dredging slurries and similar moderately abrasive media, where adjacent pipeline is also not lined or coated internally. Standpipe Wall Sensor with Standard Electrodes Pipe Wall 4) Thick polyurethane protective liner covering the entire flowtube interior and sensors (electrodes protrude liner): Used for highly abrasive media, such as mining slurries and dredging slurries. Will provide longer life than 3) above. Used when adjacent pipework is lined. Flowtube i.d. made same as pipe i.d. UniMag flowtubes come with a 1 year limited warranty against defects in material and bad workmanship. Effects of media incompatability, erosion or abrasion are not included. UniMag sensors come with a 2 year limited warranty, except when media temperature is > 180 F (80 C) and pressures > 150 psig (10 bar g). Warranty then depends on media type and conditions. The warranty may be extended to 5 years if an EMCO service technician provides start-up. This is extended pro rata for annual service contracts. EMCO may recommend materials in contact with the media. However, EMCO cannot guaranteecompatibility of those materials for any specific application. MODULAR CONSTRUCTION / TRUE FIELD REPAIRABILITY Conventional magmeters can only be repaired by the manufacturer. Repair can typically run 80% of the initial cost of the flowtube, and may take several weeks. Added cost of downtime, freight and insurance often far exceeds the initial cost of a conventional magmeter. Many users of conventional magmeters have adopted a repair-by-replacement philosophy and stock complete magmeters to minimize process downtime should a failure occur. Fusion Bonded Coating or No Coating Note: Do not use fusion bonded coating with abrasive media. Cones wear off with abrasive media, and has no effect on accuracy. With UniMag it is only necessary to stock spare sensors, with huge savings on inventory, and the flowtube never needs to leave the job site! UniMag sensors have been designed for long life in even the harshest environments, and with the most difficult media. They can be easily replaced in the field, without having to remove the flowtube from the piping, and without any special know-how or equipment. Dedicated sensor sets (preferably ordered and pre-calibrated at the factory with the flowtube) guarantee the same high accuracy is maintained after replacement. Designated sensors are interchangeable with UniMag flowtubes, and the same high repeatability and linearity are guaranteed.

4 UniMag DS Flowtube Specifications The measurement signal will not be interrupted if the optional UniMag liner or coating should ever become worn in spots. Electrode leaks and/or liner tears/holes will generally create a catastrophic (coil) failure in a conventional magmeter, causing loss of signal. UniMag will generate a useful signal under the same conditions, allowing you to conveniently schedule downtime for sensor replacement. Costly bypass piping is unnecessary since the sensors can be removed for repair and can be immediately replaced by a new sensor or temporary blanking flange. SIMPLIFIES INSTALLATION AND RETROFITS UniMag flowtubes can be manufactured to any convenient face-to-face dimension, including those recommended in ISO/DIS This greatly facilitates replacement of existing meters, without having to cut or alter the piping, or use costly spacers. In addition, UniMag flowtubes can be ordered with optional side ports for installing pressure, temperature, analytical or sampling instrumentation also being used on the process. See also DeltaMass data sheet. UNIMAG -- THE COST EFFECTIVE SOLUTION The UniMag has the features and sturdy construction to make it cost effective for simple or difficult applications. The sensor design and patented Pulsed AC coil excitation create a powerful magnetic field with low power consumption (typically < 15 W). The resultant low temperature allows Advanced Flow Technology to totally encapsulate the sensor components. The sensors are highly insensitive to shock and vibration since the encapsulation prevents movement of the coil assembly relative to the flowtube and electrodes. The grounding electrodes bond the UniMag to the process piping and prevent any stray currents from effecting the output signal. External grounding straps, or grounding rings are not normally required, even when installing the meter on non conductive piping. UniMag flowtubes can be sized for continuous media velocities as high as 15 to 30 fps (4 to 10 mps), depending upon the nature of the media, without any expected decrease in the mean-time-before-failure. Such high velocities, which often exist with older applications where it is not feasible or cost effective to modify existing piping, cause frequent electrode seal leakage and thin liner failures in conventional magmeters. UniMag solid state sensors overcome this problem. The high coil current and exciter frequency used with UniMag flowtubes creates a signal-to-noise ratio that is up to 3x higher than a conventional Continuous AC magmeter, and up to 50x higher than a conventional Pulsed DC magmeter. UniMag flowtubes can be used on slurries that create high media noise, like pulp stock and mining slurries. UniMag flowtubes can also be used to measure fluids with conductivity as low as 0.08 µs/cm (for deionized, demineralized or distilled water, consult factory). UNIMAG CALIBRATION The EMCO flow calibration installation is the largest NIST traceable facility available, having a capacity of 120,000 gpm (27,000 m 3 /h). 1/2 to 16 in. flowtubes are calibrated in either a pump loop using master meters, or in a weigh tank/diverter system. Larger flowtubes are calibrated in a submerged state within a tow tank, using master meters or swept volume. Facility accuracy is 0.1% for the weigh tank system, and 0.25% for the systems using master meters. All UniMags are traceable to the National Institute for Science and Technology (NIST) and are shipped with a calibration certificate. Unlined or fusion bond coated flowtubes with PEEK sensors may be used reliably to full vacuum.

5 UniMag DS Flowtube Specifications See specifications for 4411e transmitters ACCURACY For 16 (400 mm) Ø: ± 0.5% of rate > 2.0 fps (0.6 m/s) ± 0.01 fps (±0.003 m/s) for < 2.0 fps (0.6 m/s) Accuracy is traceable to the National Institute of Science and Technology. A NIST traceable calibration certificate is provided with each flowtube. Accuracy is unaffected by electrode coatings such as sewage grease, calcium carbonate, algae or similar. Note: For media such as ferric chloride, ferric sulphate (Odophos), high temperature paper mill liquors, lime mud or similar highly conductive media, flowmeter performance can be adversely affected. Please consult EMCO for these types of applications, otherwise performance guarantee is null and void. MINIMUM STRAIGHT PIPING RUNS Piping Upstream Piping Requirement Downstream Piping Requirement Minimum Requirement 10 Diameters 5 Diameters Single elbow, or tee upstream 10 Diameters 5 Diameters Two elbows coupled in same plane 10 Diameters 5 Diameters Two elbows, close coupled and out of plane 20 Diameters 5 Diameters Pump, blending point, control valve upstream 30 Diameters 5 Diameters Pump, control valve downstream FLOW RANGE 0-2 f/s (0-6 m/s) minimum to 0-30 f/s (0-10 m/s) maximum or 0-5D 2 gpm minimum to 0-75D 2 gpm maximum, where D is in inches ( D 2 m 3 /h minimum to D 2 m 3 h maximum, where D is in millimeters) COIL EXCITATION Pulsed AC excitation. Consult data sheets for 4411e for more information. MEDIA CONDUCTIVITY > 1 µs/cm standard > 0.08 µs/cm optional. For < 5 µs/cm use UniMag pre-amp option. For deionized, distilled, or demineralized water, consult factory. Note: For < 5 µs/cm an integral pre-amp is used. ENVIRONMENTAL PROTECTION 5 Diameters NEMA 6 and IP68 indefinitely submersible to 30 ft. (10 m) water column, or NEMA 4X and IP65. Entela approved to UL and CSA standards for safety in ordinary locations and explosive atmospheres Class 1, Div. 2, Groups C, D, T4. For explosive atmospheres, see Ordering Code. GROUNDING Grounding electrode on each sensor NOTE: 1. For cathodic protected pipes, consult. 2. For transmission to a remote transmitter > 100 feet (30m), or when excessive unequal potentials exist between the pipeline and the flowmeter cable shields, it may be necessary to have a grounding ring or other grounding arrangement installed. Consult. Such excessive unequal potentials are beyond the control of EMCO and additional cost of remedy is extra to that of our normal supply.

6 CABLE TYPE UniMag DS Flowtube Specifications See specifications for 4411e transmitters There are 3 separate cables used to the remote 4411e transmitter: 1 cable is for the sensing electrodes, 1 cable for the coil energizing coils and 1 cable for the reference coils. Each cable is 2-core multistranded and overall shielded, 2 x 18 gauge (US) e.g. Beldon #8760 or 2 x 0.75 mm 2. Additional cable of the same type is used for a pre-amp in the junction box. For ATEX Zone 2 applications IEC approved cables must be used, with the 4411e transmitter in the safe area. For Class 1, Div. 2 applications cables must run in conduits or Teck metal clad cable, with the 4411e transmitter in the safe area. CABLE LENGTH TO TRANSMITTER 50 feet (15 m) as standard supply. Special distance cabling maximum 300 feet (30 m). For cable lengths > 100 feet (30 m) a pre-amp is installed in the junction box. Note: For distances up to 30 feet (10 m) all cables may run in the same conduit. Longer distances require that the cables run in separate conduits, approximately 1 foot (300 mm) apart. The energizer coil and reference coil cables may run in the same conduit longer than 30 feet, but the electrode cable must be separate. For applications to ATEX Zone 2 requirements only one cable is permitted per cable connector. MAXIMUM CABLE LENGTH < 3 micros/cm: max. 30 feet (10 m) > 3 micros/cm: max. 100 feet or (10 x C) feet or 30 m max. or (3 x C) m UNIMAG MATERIALS OF CONSTRUCTION (REFER TO ORDERING CODE) FLANGES/FLOWTUBE Carbon steel, 316 stainless steel, HDPE Standard 1 year warranty against material defects and bad workmanship, but not including media compatibility, erosion and abrasion or for media > 180 F / 80 C May be extended to 5 years if an EMCO service technician provides start-up. This is extended pro rata for annual service contracts. Maximum pressure and temperature rating of the flowtube may be limited by the flange type selected (refer to appropriate flange specifications). Flowtubes can be specially ordered with plain ends or with butt weld ends. NOTE: For HDPE temperature and pressure rating, consult factory. MAXIMUM TEMPERATURE (Maximum pressure based on sensor) LINERS/COATINGS Fusion Bonded Epoxy -40 F to +240 F (-40 C to +116 C) Conforms to USA National Sanitation Foundation Standard NSF61 and AWWA Standard C213 for drinking water. Polyurethane Tefzel Ryton ELECTRODES SENSORS (See ordering code for applicable gaskets and electrode seals) 175 F max (80 C max) (Not recommended for high vacuum applications) Conforms to NSF61 and AWWA C213 for drinking water. Heavy duty polyurethane is suitable for high velocity mining slurries and similar media (see note 3). 240 F max (115 C max) based on water. Not recommended for high vacuum applications. Other media may reduce this temperature. 350 F max (177 C max). Used for paper mill liquors, lime muds and similar high conductivity media. AISI 316 stainless steel, Hastelloy B and C, Titanium, Tantalum, Monel Polyurethane -175 F max and 150 psig max (80 C max and 10 bar g max). Conforms to NSF61 and AWWA C213 for drinking water PVDF -240 F max and 356 psig max (115 C max and 25 bar g max). Full vacuum capability. The temperature rating shown is for water and may be lower for other media due to corrosion considerations (consult manufacturer). PVDF is approved by the US Food and Drug Administration #21 CFR UHMWPE -175 F max and 150 psig max (80 C max and 10 bar g max). PEEK -350 F max and 356 psig max (176 C max and 25 bar g max). Full vacuum capability. NOTES 1. Sensor assembly includes a non-wetted carbon steel cover flange, fusion bonded polyethylene protected. 2. Sensor assemblies are supplied with outer cover flanges, 30 ft (10 m) of cable, re-enterable potting gel, junction box, conduit and stainless steel bolts. Special length cable on request. 3. Temperature differential between process and ambient limited to 140 F (60 C) for polyurethane sensor, and 212 F (100 C) for PVDF sensor. 4. Standard 2 year warranty against material defects and bad workmanship, but not including media compatibility, erosion and abrasion or for media > 180 F / 80 C. Sensor Electrode Seals Sensor Gaskets Viton, Kalrez, Chemraz or Teflon (GoreTex) Elastomer, Teflon (see ordering code for sensor combination) Sensor retention flange is carbon steel with stainless steel bolts.

7 UniMag DS Flowtube Ordering Information A 4411e transmitter must be used with the flowtube and ordered separately. DS 08 C E T X R 1 A A DS = UniMag DS Flowtube Nominal Size 02 = 2 in. (50 mm) 2H = 2½ in. (65 mm) = 3 in. (80 mm) to 16 in. (400 mm) O Flowtube / Flange Materials C = Carbon Steel T = All 316 Stainless Steel A = 316 Stainless Steel Flowtube, Carbon Steel Flanges H = HDPE Flowtube, Non-Wetted Carbon Steel Flanges Sensor Materials E = PVDF with elastomer gaskets, Viton seals D = PVDF with Teflon gaskets, Viton seals P = Polyurethane with elastomer gaskets, Viton seals F = PVDF with Teflon gaskets, Kalrez seals K = PEEK with Klinger gaskets, Chemraz seals U = UHMWPE concave, elastomer gaskets, Viton seals H = PEEK, Klinger gaskets, Teflon seals (note 8) C = Polyurethane concave, elastomer gaskets, Viton seals (> 16 / 400 mm diameter) T = Concave Teflon, Teflon gaskets, Kalrez seals Electrodes (Viton Seals) (Note 6) T = AISI 316 Stainless Steel B = Hastelloy B (small) C = Hastelloy C (small) I = Titanium W = Hastelloy C (large - see note 7) X = Hastelloy B (large - see note 7) A = Tantalum H = Hastelloy C high compression (note 8) M = Monel Flowtube Liners and Coatings X = Fusion Bonded Epoxy Coating (note 2) P = Polyurethane inside and outside M = Heavy Duty Polyurethane inside, epoxy enamel outside (note 3) Z = Heavy Duty Tefzel (ETFE) (note 4) N = No Coating Inside, Fusion Bonded Epoxy Outside R = Ryton coated inside, epoxy enamel outside NOTES Transmitter Supply A = 120V, 60 Hz transmitter supply B = 230V, 50 Hz transmitter supply C = 120V, 50 Hz transmitter supply S = Special Options A = Pre-amplifier (note 5) B = Extra Long 316 stainless steel electrodes (note 6) W = Special Warranty (EMCO discretion) - No extra charge E = Extra Length Cables L = Special Lay Length P = Sampling Port ¾ NPT female N = Sampling Port 1½ NPT female O = No Options - No Extra S = Special - may be a combination of features (note 1) Process Connections 1 = ANSI 150 RF (< 28 in.); ANSI/AWWA C207 Class D FF ( 28 in.) 2 = ANSI 300 RF 3 = AWWA FF (specify class) 4 = DIN/BS4504 PN6 5 = DIN/BS4504 PN10 6 = DIN/BS4504 PN16 NOTE: Options 4, 5, 6 have the same dimensions up to 6 in. (150 mm) 7 = J1S10krf 8 = BS/AS2129 Table D 9 = BS/AS2129 Table E C = Plain Ends Transmitter Installation R = 50 ft. (15 m) cables NEMA 6/IP68 indefinitely submersible to 30 feet w.c. X = Entela approved to NEC/CSA Class 1, Div. 2, Grp C, D, Temp. T4. 50 feet cables (15 m) C = Entela approved to ATEX Zone feet cables (15 m) 1. All special orders must include a complete description along with the ordering code. Use for combinations. 2. Version X is fusion bonded inside and outside. 3. Recommended for mining slurries and similar fluids. Please include internal piping diameter of mating pipe so UniMag can be manufactured to match. 4. Do not use with abrasive slurries. Tefzel is inside and outside. 5. Pre-amp required in junction box for fluid conductivity < 5 µs/cm. For demineralized, deionized or distilled water, consult EMCO. 6. Extra-long electrodes are provided for thick, non-fluidic coating applications. Advise thickness. 7. Use W or X electrodes and K PEEK sensors only. 8. Use H electrodes on paper mill liquors, and lime mud > 200 F (93 C). Use with H sensors only.

8 UniMag DS Series Dimensions and Weights W L X Optional sample or pressure port downstream of sensor (unidirectional) X View On XX Nominal Size D Dimension L Dimension W Approximate Weight Inches mm Inches mm Inches mm LB KG NOTES 1. Flowtubes with plain ends, without flanges, suitable for pipe couplings or butt welds may be supplied 2. Flowtubes can be made to order with different length dimension L 3. Flowtubes 2 to 6 in. (50 to 150 mm) equipped with a sampling port have an L dimension of 15 in. (380 mm), a division of Spirax Sarco, Inc Lefthand Circle, Suite C Longmont, CO Phone: or Fax sales@emcoflow.com website:

UniMag DT Series Magnetic Flowtubes

UniMag DT Series Magnetic Flowtubes EMCO UniMag TM Magnetic Flowmeters UniMag DT Series Magnetic Flowtubes The UniMag Magnetic Flowmeter System consists of the patented UniMag Flowtube and the 4411e Transmitter. UniMag Magnetic Flowmeters

More information

UniMag DT Series Electromagnetic Flow Tubes

UniMag DT Series Electromagnetic Flow Tubes Description Spirax Sarco s UniMag DT Magnetic Flow Meter System consists of the patented UniMag Flow Tube and EFT10 Flow Transmitter. UniMag sensors are unique because they do not require a liner and can

More information

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Electro-Magnetic Flowmeters Sensors MagMaster MFE Data Sheet (US) Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1. Two-year

More information

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date FLOWMETRIX SA Doc Date 17.07.2012 PERFORMANCE * 0,5% of rate (Standard) * 0,25% of rate (Optional) * 1000 : 1 operable flow range * Excellent repeatability * Optional Bi-directional measurement * Advanced

More information

Field IT Electro-Magnetic Flowmeters Sensors

Field IT Electro-Magnetic Flowmeters Sensors Data Sheet Field IT Electro-Magnetic Flowmeters Sensors MagMaster MFE Unrivalled flow performance ±0.2% accuracy. Pulsed DC Technology Incorporates Benefits of AC Systems Operable flow range of 1000:1.

More information

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance Specifications MagMaster MFE Series Electromagnetic Sensors nn Unrivalled flow performance ±0.2% accuracy. nn Pulsed DC Technology Incorporates Benefits of AC Systems nn Operable flow range of 1000:1.

More information

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications FIELD DEVICES - FLOW Product Specifications Logo 9100A Series Magnetic Flowtubes with Ebonite Liners 1 to 78 in (25 to 2000 mm) Nominal Flowtube Sizes The Foxboro brand 9100A Series Magnetic Flowtube together

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

SITRANS F M flow sensors 711/A and 711/911E

SITRANS F M flow sensors 711/A and 711/911E s flow sensors 711/A and 711/911E flow sensors 711/A and 711/911E Introduction Application Mode of operation, operation Mode of operation All electromagnetic flow measurements are based on Faraday s Law

More information

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters 8000A/8300/9300A/9100A/9200A SERIES S Perfect for municipal water & wastewater applications 1.6 to 900 mm (1/16 to 36

More information

9300A Series Flanged Magnetic Flowtubes

9300A Series Flanged Magnetic Flowtubes Product Specifications 9300A Series Flanged Magnetic Flowtubes pfa Lined, 1 through 12 Inch; ptfe Lined, 1/2 through 16 Inch; Polyurethane Lined, 8 through 16 Inch PSS 1-6F4 A FEATURES pfa Withstands Effects

More information

OPTIFLUX 6000 Technical Datasheet

OPTIFLUX 6000 Technical Datasheet OPTIFLUX 6000 Technical Datasheet Electromagnetic flow sensor for hygienic and sanitary applications Robust stainless steel housing for hygienic and aseptic operation Fully suitable for CIP and SIP Typical

More information

PMG MAGNETIC FLOWMETER

PMG MAGNETIC FLOWMETER PMG MAGNETIC FLOWMETER Flow Pressure Level Temperature measurement monitoring control Flow Ranges 0.015-0.5 Through 350-10600 GPM 1/2 to 12 Sizes Accuracy ±0.5% or ±0.25% of Reading Viscosity and Density

More information

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement

More information

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Flow rate measurement is independent of density, temperature, viscosity and pressure Pulsed coil excitation to

More information

Rosemount 8750WB Magnetic Flowmeter System

Rosemount 8750WB Magnetic Flowmeter System Rosemount 8750WB Magnetic Flowmeter System for Utility, Water, and Wastewater Applications Product Data Sheet 00813-0200-4750 Rev AA THE 8750W MAGNETIC FLOWMETER Rosemount reliability customized for Water,

More information

ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL 30119-03 Rev. 4.8 April, 2013 TABLE OF CONTENTS Section Page 1. INTRODUCTION...1 1.1 Description...1 1.2 Uncrating...1 1.3 Serial

More information

Variable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500

Variable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500 Data Sheet (US) Variable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500 Rugged body design with all type 300 stainless steel construction Metering tube can be removed for range change

More information

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter The 10D1477 electrodeless ceramic lined wafer sensors and 50XM1000 transmitters are pulsed DC magnetic flowmeters. These

More information

유량계전문제조업체. Electro Magnetic FLOWMETER

유량계전문제조업체. Electro Magnetic FLOWMETER 유량계전문제조업체 w w w. f c k o r e a i n s. c o m Electro Magnetic FLOWMETER ELECTRO-MAGNETIC FLOW METER Contents Principle of Operation 04 Grounding Method 05~07 Piping Installation 08 CN-400 CNT-2 Flanged

More information

Electromagnetic Flow Meter Owner s Manual HARDWARE

Electromagnetic Flow Meter Owner s Manual HARDWARE Electromagnetic Flow Meter Owner s Manual HARDWARE Compact Magnetic Flowmeter (Flange Connection) Sanitary Magnetic Flowmeter (Tri clamp Connection) Part No. 910000 Rev.C Content 1. GENERAL INFORMATION...2

More information

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability

More information

Full Profile Insertion

Full Profile Insertion FPI Mag Meter Full Profile Insertion High Performance Electromagnetic Flow Meter Municipal Market Product Presentation Manufactured exclusively by McCrometer, Inc. Hemet, CA USA 55+ Years of Experience

More information

OPTIFLUX Electromagnetic Flow Sensor

OPTIFLUX Electromagnetic Flow Sensor OPTIFLUX 2000 Technical Datasheet Electromagnetic Flow Sensor Engineered and manufactured for the water and wastewater industry All relevant approvals for potable water Long-term reliability and durability

More information

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL From McCROMETER 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279 Fax (951) 652-3078

More information

Hydro-Flow Model 2300 Installation and Operation Guide B

Hydro-Flow Model 2300 Installation and Operation Guide B Hydro-Flow Model 2300 Installation and Operation Guide 5700508-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Electrical Connections.. 7 Mechanical and Electrical

More information

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA SENSOR MUT2300 Electromagnetic flowmeter The electromagnetic flowmeter designed for the toughest applications DS401-1-USA Sensor MUT2300 The MUT2300 sensors represent the state of the art of Euromag International

More information

Technical Data Sheet IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters. ... for water and wastewater measurements

Technical Data Sheet IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters. ... for water and wastewater measurements Technical Data Sheet KROHNE 05/2004 GR/PRINTO IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters... for water and wastewater measurements short inlet and outlet runs unaffected by contamination, solids,

More information

flow measurement solutions RIM10 series rotor insertion flowmeters

flow measurement solutions RIM10 series rotor insertion flowmeters flow measurement solutions RIM10 series rotor insertion flowmeters R I M 1 0 RIM10 series rotor insertion flowmeters Versatile enough for almost any challenge Spirax Sarco s RIM10 rotor insertion flowmeters

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

Positive Displacement Flowmeters

Positive Displacement Flowmeters Positive Displacement Flowmeters SRZ series Helical screw positive displacement flowmeters Positive Displacement Flowmeters Two highly accurate cycloid-shaped screw spindles mesh and rotate inside a cylindrical

More information

Electromagnetic Flow Monitor magphant

Electromagnetic Flow Monitor magphant Technical Information TI 036D/24/ae Electromagnetic Flow Monitor magphant Flow monitoring in 1 to 80 pipes with conductive liquids Monitoring and measurement Flow monitoring with selectable limit values

More information

Botlek Studiegroep Basics Electro Magnetic Flowmeters

Botlek Studiegroep Basics Electro Magnetic Flowmeters Arjan Meerveld, ABB b.v. / 2 juni 2016 Botlek Studiegroep Basics Electro Magnetic Flowmeters ABB Group 8 June 2016 Slide 1 Measuring Principle of EMF Faraday s law (year 1831) Measurement electrodes Magnetic

More information

VLM20 In-line Vortex Flowmeter

VLM20 In-line Vortex Flowmeter ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid

More information

Magnetic Inductive Flowmeter EP / UMF2 (B)

Magnetic Inductive Flowmeter EP / UMF2 (B) Magnetic Inductive Flowmeter EP / UMF2 (B) High accuracy 0.3 % of reading No maintenance required no pressure drop different lining materials different electrode materials inexpensive earthing electrode

More information

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250 Data sheet Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250 MBS 8200 is a series of compact pressure transmitters developed to withstand the pressure pulsations and vibrations known

More information

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of

More information

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG SENSOR MUT2300 Electromagnetic flowmeter The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG Sensor MUT2300 The MUT2300 sensors represent the state of the art of Euromag International

More information

HSU, HSUL & JCU. Submersible Pumps

HSU, HSUL & JCU. Submersible Pumps HSU, HSUL & JCU Submersible Pumps HSU, HSUL, JCU Model HSU Hydro-solids pumps. Recessed impeller easily accomodates large, stringy and fibrous solids without clogging. Because it is completely submersible,

More information

Glass Tube Full-View Flowmeters

Glass Tube Full-View Flowmeters Data Sheet Brooks 1110 and 1140 Series Glass Tube Full-View Flowmeters Model 1110 Full-View Flowmeter (NPT Connections) Model 1140 Full-View Flowmeter (Flange Connections) FEATURES AND BENEFITS Wide choice

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

AST10 & AST51 Contacting Conductivity Sensors

AST10 & AST51 Contacting Conductivity Sensors AST10 & AST51 Contacting Conductivity Sensors AST10 Contacting Conductivity Sensors in K=3.0/cm cell constant (without cap & without compression fitting) & K=10.0/cm cell constant with Hastelloy C-276

More information

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview Siemens AG 2010 low Measurement Overview Design Compact or remote mounting possible Easy plug & play field changeability of transmitter Ex ATEX and M/CSA versions High temperature sensor for applications

More information

Process Industry. Diaphragm Seal Solutions

Process Industry. Diaphragm Seal Solutions Process Industry Diaphragm Seal R Overview Diaphragm Seal Systems Provide Protection to Ensure Safety, Reliability Diaphragm seal systems protect gauges from hot, viscous, contaminated or corrosive media.

More information

Electromagnetic flowmeters for water and seewage

Electromagnetic flowmeters for water and seewage 09/97 Electromagnetic flowmeters for water and seewage Primary head Compact flowmeters Installation instructions AQUAFLUX F 0 K 020 K 080 K CONTENTS Storage and transport Pagesn 3-4 Installation in the

More information

G2 Industrial Grade Meters

G2 Industrial Grade Meters G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine

More information

Insertion magnetic inductive flowmeter

Insertion magnetic inductive flowmeter Insertion magnetic inductive flowmeter Sensor without moving parts Flowmeter with On/Off control Application related calibration by Teach-In function Clean in place (CIP) FDA-compliant materials Type 8041

More information

Hydro-Flow Model 3100

Hydro-Flow Model 3100 Hydro-Flow Model 3100 Installation and Operation Guide installation and operation guide Contents: Understanding Your Flow Meter... 1 Identifying Your Flow Meter...2 Installing Your Flow Meter...3,4 Making

More information

Ar-Mite TM Low Flow Armored Flowmeter

Ar-Mite TM Low Flow Armored Flowmeter Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm

More information

Electromagnetic flowmeters

Electromagnetic flowmeters 02/97 Electromagnetic flowmeters Primary heads Installation instructions ECOFLUX IFS 1000 F Compact flowmeters IFM 1010 K IFM 1080 K CONTENTS Installation in the pipeline Pages 4-5 and 7-8 Grounding Pages

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

PSF50 Paddle flow switch

PSF50 Paddle flow switch Paddle Flow Switch Paddle Flow Switch PSF50 Paddle flow switch Paddle flap flow / no flow switch Economically priced flow/no flow paddle operated flow switch. Simple and reliable design for liquids up

More information

Pressure Transmitter for wind turbine applications MBS 8200 and MBS 8250

Pressure Transmitter for wind turbine applications MBS 8200 and MBS 8250 Data sheet Pressure Transmitter for wind turbine applications MBS 8200 and MBS 8250 MBS 8200 is a series of compact pressure transmitters developed to withstand the pressure pulsations and vibrations known

More information

Technical Offer. ViscoPro Measure Viscosity and Temperature on line for continuous process improvement

Technical Offer. ViscoPro Measure Viscosity and Temperature on line for continuous process improvement Technical Offer ViscoPro 2100 2015.2 Measure Viscosity and Temperature on line for continuous process improvement Advantages: Long and stable calibration Vibration and flow rate insensitivity Low maintenance

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration

More information

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Pressure transmitters for heavy duty applications MBS 3200 and 3250 Data sheet Pressure transmitters for heavy duty applications MBS 3200 and 3250 The compact high temperature pressure transmitter MBS 3200 is designed for use in hydraulic and almost all industrial applications,

More information

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER TECHNICAL INFORMATION METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER Electronic Transmitter INTRODUCING THE METAL TUBE VAREA-METER U.S. Filter/Wallace & Tiernan Products straight through metal tube

More information

KDM ARMORED FLOW METER & SWITCH

KDM ARMORED FLOW METER & SWITCH KDM ARMORED FLOW METER & SWITCH Flow Pressure Level Temperature measurement monitoring control S2 Short Installation Length SS, PTFE or Hastelloy Wetted Parts Analog Output Available 110 F to + 390 F Temperature

More information

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters Electronic Pressure Catalog > Hazardous Area > E-10, E-11 Type E-10, E-11 Hazardous Area Explosion-proof Transmitters Meets ANSI / ISA 12.27.01-2003 single seal requirements - no dual seal required Applications

More information

Variable Area Flowmeters Ori-Flowrator TM Meters

Variable Area Flowmeters Ori-Flowrator TM Meters Data Sheet (US) Variable Area Flowmeters Ori-Flowrator TM Meters 10B4000 Low installation cost Linear indication over 12-1/2 to 1 flow range Inexpensive method of measuring large flow rates in direct flow

More information

Ultra Mag SUBMITTAL PACKAGE

Ultra Mag SUBMITTAL PACKAGE SUBMITTAL PACKAGE Date: McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 PHONE (951) 652-6811 TOLL FREE (800) 800-8804 FAX (951) 652-3078 www.mccrometer.com 3255 WEST STETSON AVENUE HEMET, CALIFORNIA

More information

Appendix. Clearance. Skewed profiles. Application Schematics

Appendix. Clearance. Skewed profiles. Application Schematics Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will

More information

Micro Motion Model D and DL Coriolis Flow and Density Meters

Micro Motion Model D and DL Coriolis Flow and Density Meters Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,

More information

Magnetic-inductive flow meter for hazardous areas

Magnetic-inductive flow meter for hazardous areas Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

Hot Tap Insertion Vortex

Hot Tap Insertion Vortex Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design

More information

Smart Electromagnetic Flowmeter Detector for Sanitary use

Smart Electromagnetic Flowmeter Detector for Sanitary use MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector for Sanitary use Model MGS28U OVERVIEW The MagneW3000 PLUS Smart Electromagnetic Flowmeter for Sanitary use is a high-performance and highly-reliable

More information

AquaMaster4 Electromagnetic flowmeter flanged sensor

AquaMaster4 Electromagnetic flowmeter flanged sensor ABB MEASUREMENT & ANALYTICS OPERATING INSTRUCTION AquaMaster4 Electromagnetic flowmeter flanged sensor The ideal flowmeter for potable water distribution networks, revenue metering and irrigation applications

More information

HYMAX GRIP Wide-Range Restraint Solutions

HYMAX GRIP Wide-Range Restraint Solutions HYMAX GRIP Wide-Range Restraint Solutions HYMAX GRIP. THE TEETH MAKE THE DIFFERENCE. There are many situations that require couplings with additional restraining power. HYMAX restraint products combine

More information

Model FVP General Specification. Flanged Vortex Plate. Product Features

Model FVP General Specification. Flanged Vortex Plate. Product Features Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from

More information

Why measure viscosity in-line?

Why measure viscosity in-line? BROOKFIELD _ WHY MEASURE VISCOSITY IN-LINE Why measure viscosity in-line? Why Measure Viscosity In-Line? Practical application of viscosity measurement data often leads to the need for in-process control

More information

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors RHM 015L/02L/03L/04L Compact Low Flow Coriolis Flow Sensors Features Pressure ratings up to 20000 psi / 1379 bar Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty less than 0.10%

More information

Electromagnetic flowmeter EMKO E

Electromagnetic flowmeter EMKO E Electromagnetic flowmeter EMKO E - Quality design - High corrosion resistance - Reliable measurement principle Doc. no.: 70, en_cat_emkoe, 8/2015 Description Electromagnetic Flowmeter EMKO E consists of

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

NEW QUICK CABLE-TO-SENSOR RELEASE,

NEW QUICK CABLE-TO-SENSOR RELEASE, Models 399 and 399VP Product Data Sheet PDS 71-399 October 2000 ph/orp Sensors NEW OPTIONS to meet a variety of application requirements, including: * Low ionic strength water * Processes with hydrofluoric

More information

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

WATERFLUX 3000 Technical Datasheet

WATERFLUX 3000 Technical Datasheet WATERFLUX 3000 Technical Datasheet Electromagnetic flowmeter Easy installation without straight inlet or outlet lengths For installation in small spaces Wide range of approvals for potable water The documentation

More information

MODEL 1100 TURBINE FLOW METER

MODEL 1100 TURBINE FLOW METER MODEL 1100 TURBINE FLOW METER INSTALLATION & INSTRUCTION MANUAL 8635 Washington Ave. Racine, Wisconsin 53406 Phone: 800.433.5263 Fax: 800.245.3569 www.hedland.com 2 OPERATIONAL START-UP Fluid entering

More information

Armstrong In-Line and Insertion Vortex Flow Meters

Armstrong In-Line and Insertion Vortex Flow Meters Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line

More information

Industrial Pressure Transmitters

Industrial Pressure Transmitters Industrial Pressure Transmitters Type S-10, S-11 Applications Hydraulics and pneumatics Test equipment Pump and compressor control Liquid level measurement Special Features Standard ranges available from

More information

Start FINAL. Step 8: Process Leak Protection (Optional) Step 9: Power up the Transmitter. Step 10: Check Process Connections

Start FINAL. Step 8: Process Leak Protection (Optional) Step 9: Power up the Transmitter. Step 10: Check Process Connections Rosemount Magnetic Flowmeter System (Transmitter and Flowtube) with FOUNDATION fieldbus ProductDiscontinued Start Step 1: Pre-Installation Step 2: Handling Step 3: Mounting Step 4: Installation (Flanged

More information

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

TEK-F LUX 1400A. Electromagnetic Flowmeter.  Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW Technology Solutions TEK-F LUX 1400A Electromagnetic Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Electromagnetic flowmeters are also

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)

More information

LCMass Series Mass Flow Sensor

LCMass Series Mass Flow Sensor LCMass 100-140 Series Mass Flow Sensor Technical Data Sheet HIGH ACCURACY The LCMass 100 achieves a ±0.15% accuracy on liquids. COMPACT ECONOMIC DESIGN Straight twin-tube design allows for an overall smaller

More information

D1 Series Top Guided Single Seated Control Valves

D1 Series Top Guided Single Seated Control Valves D1 Series Top Guided Single Seated Control Valves Model D1S Overview Model D1S globe control valves are with bolted bonnet and top guided contoured trims. The design facilitates easy access to internal

More information

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57 Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to

More information

Hydro-Flow Model 2200 Installation and Operation Guide B

Hydro-Flow Model 2200 Installation and Operation Guide B Hydro-Flow Model 2200 Installation and Operation Guide 5700507-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Making Electrical Connections. 7 Mechanical and Electrical

More information

Transmitting Transducer. Gas/Air Velocity Range:

Transmitting Transducer. Gas/Air Velocity Range: RNG Series Insertion-Style Gas Flow Meter The RNG Series meter is an insertion-style vortex shedding flow meter designed to offer high accuracy measurements over an extremely large flow range. The meters

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008 Product Data Sheet PDS 71-400/rev.I December 2008 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS). PRODUCT APPLICATIONS / APPLICATION QUALIFICATION DIMENSIONAL SPECIFICATIONS MECHANICAL DIMENSIONS: INCHES (mm) DOPPLER ULTRASONIC FLOW METER Carbonated liquids Mining slurry Drilling mud Coal-seam water

More information

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250 Data sheet High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250 The compact heavy duty pressure transmitter type MBS 2200 and MBS 2250 are designed for use in severe

More information

OEM Pressure Transmitters

OEM Pressure Transmitters OEM Pressure Transmitters Type ECO-1 Applications Hydraulics and pneumatics Mechanical engineering General industrial applications Special Features Pressure ranges from 0-15psi to 0...15,000psi 4-20 ma

More information

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors.

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors. Product Data Sheet PS 00388 February 2002 Model D and DT Mass Flow and Density Sensors www.micromotion.com Model D and DT sensors Micro Motion Model D sensors set the standard for Coriolis flowmeters nearly

More information

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement Sensing the pulse of industry tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement tekflo sensors are proud to present their tekson TS Series ultrasonic water energy meter, which uniquely

More information

Differential Pressure Gauges (701P Series)

Differential Pressure Gauges (701P Series) Applications Equipped two Process Connections Indicating low and high pressure Measuring differential pressure as well as liquid or flow levels Recommended to use 3-way & 5-way valve manifold Pressure

More information